Loading...
HomeMy WebLinkAboutRABBIT CREEK VIEW & HEIGHTS BLK 5H LT 32ARabbit k View & H ight Block 5H Lot 32A #020-551-50 Municipality of Anchorage On-Site Water and Wastewater Program• (907) 343-7904 Page 1 of 3 ON-SITE WASTEWATER INSPECTION REPORT Permit Number: OSP131368 PID Number: 020-551-50 Dwelling: ■❑ Single Family (SF) ❑ Duplex(D) ❑ Multiple(SF and/or D) Project: ■❑ New ❑ Upgrade Name: Patricia A. Heim ABSORPTION FIELD Address ❑ Deep Trench ❑ Shallow Trench ❑ Bed ❑ Mound 16600 Olson Circle Anchorage, AK 99516 ❑ Other Phone Number of Bedrooms Soil Rating Total depth from original grade 599-5500 One GPD/SF Ft. LEGAL DESCRIPTION Depth to pipe invert from original grade Gravel depth beneath pipe Subdivision Block Lot Ft. Ft. Rabbit Creek View & Heights 5H 32A Fill added above original grade Gravel length Township Range Section Ft. Ft. Gravel width Beds:Number of Lines Distance between lines SEPARATION DISTANCES Ft. Ft. To Septic Absorption Lift Station l Holding Sewer Total absorption area Number of trenches Dist.between trenches From Tank Field Tank Line Ft2 Ft. Well NA NA N/A >75' >25, TANK 0 Septic 0 S.T.E.P. 0 Holding 0 Other Manufacturer Capacity Surface Water NA NA NA >100' Anchorage Tank 2,000 Gal. Material Number of compartments Lot Line NA NA NA >5' NA Steel One Foundation NA NA N/A >10' LIFT STATION Manufacturer Capacity Curtain Drain None Noted Gal. Pump on level at Pump off level at High water alarm at Remarks High level alarm in place in house. Tank is secured to prevent flotation. in. in. in. Pump make and model Electrical Inspections performed by PIPE MATERIAL House to tank D3034Tank to Installer drainfield Wilco Drainfield CO/MT D3034 Inspector J. Berkram BENCH MARK (Assumed elevation)100 ft Inspection 1'' 7/23/14 2nd 7/24/14 Location and description dates: sd 4th Bottom of Siding COMMUNITY DEVELOPMENT DEPARTMENT APPROVAL Engineer's Stamp Conditional Approval: Date 0*r<Q,..• .S i1 49 TH /\ 44.0 / .. Michael E.Anderson : �f�F ` 4381-E •k%Gie 06011 f srF • $/17/1$.•• 'Ap. Approved Date SO7/I S' Nit,enP ESSIONP .• A Inspection Report_9-1-12.doc Municipality of Anchorage DEVEOPMENT SERVICES DEPARTMENT PID No.: 020-551-50 4700 Elmore Road Anchorage,AK.99519-6655-343-7904 Permit Number: OSP131368 Page 2 of 3 RABBIT CREEK HEIGHTS \ LOT 32A, BLOCK 5H 0 25,674 S.F. Ks A' � O"Y One \\ \ Bedroom • •� Home <> 2,000 Gall.• a� Holding Tank AV „owe- N. Pump Truck \ 7 Access \ .>S• 4)a '<cp 100' R°drug A B AV ® 17.5' \ Proposed 22.4' 22.1' \ Well \ O \ • G% 1: . •43ti LEGEND Fo \ -.) PV — 6" Pump Vent s� \ o`t'AV - Alarm Vent 7 3�->ee\ MH - Manhole go \ FCO - Foundation Cleanout •oo' \ \ \ 414 •4.,`P�E..... ........ ..i A?�` •' #1 Iff 5 49thp � ��i .°*$ P A N A S - B U I T MICHAEL E. ANDERSON ;' jilj /�r�.• No. CE-4381 • or SCALE 1' = 40' X44; RO`SSat Municipality of Anchorage Page 3 of 3 DEVEOPMENT SERVICES DEPARTMENT 4700 South Bragaw Street Anchorage,AK. 99519-6655- 343-7904 On-Site Wastewater Disposal System or Well Inspection Report Permit Number: OSP131368 PID No.: 020-551-50 99.91 � Q x}00.44 E 2,000 Gallon Holding Tank 96.7 91.25 NOTE: Holding Tank only placed under this permit. Tank is secured with cable and concrete in accordance with Municipal Code. .44 . 49th �� •' �` •• • � r r PROFILE AS-BUILT ICHAEL E. ANDERSON Cf•' NO. CE 4381 • No Scale � EIJ P�• �� � g r STATE OF ALASKA c.�t(t• 1� �3t �(1 i t , Inc.I C,. DEPARTMENT OF NATURAL RESOURCES DIVISION OF MINING,LAND& WATER ?1. 11iri7 .M., _ .;'jt; SeWATER WELL LOG . .. . ; ,a , ••,,,' f_1 - Drilling Started:03/26,2014Complcted: 03/27 /2014 City/Borough: Subdivision: BLOCK LOT Property Owner Name&Address: Patty Heim Rabbit Crk View & 5H 32A Site: Bear Valley 16600 Olson Cir Anchorage Heights Anchorage, AK 99516 I Meridian Township Range Section �/a of �/a of_ IAof 1/4 BOREHOLE DATA(from top of casingpepth Drilling method: (X)Air rotary. ( ) Cable tool,Other Material:Type.Color&wetness I From I To Well use: ( ) Public supply, (x )Domestic. Other stickup 0 2 Depth of hole: 116 ft,Casing stickup: 2 ft Casing type:steel Thickness: .250 _inches Casing diameter: 6 inches Casing depth: 116 ft peat 2 8 Liner type: Diameter: inches Depth: ft Static water(from top of casing):Attpcianft on 03/ 77!7014 glacial till 8 35 Pumping level&yield: feet after _-hours at -_ gpm Recovery rate: 25 gpm,Method of testing: airlift sandy glacial till 35 80 Development method: airlift Duration: 1 hour clay 80 110 Well intake opening type: (x ) Open end.( )Open hole,Other_ Screened: Start: ft,Stopped ft Screen type: Slot/mesh size: sand &gravel w/ H2O 110 116 Perforated: Start: ft, Stopped: ft _. __ Start: ft. Stopped: ft Note: Grout type: bentonite Volume - Depth; from ground surface ,to, 20 .ft Pump intake depth: ______ft Pump size: hp, Brand name: — — WATER QUALITY TESTING Was well disinfected upon completion? (x) Yes. ( )No Conform Nest CoUIOOr L Method of disinfection:.CalcjUIf.HypOchJ.orlte.(C.hJ0r1fe)... Nitrates N1 Driller comments/disclaimers- Arsenic N b e� + 24/a Well driller name: Curt Company name: Hefty Drilling, Inc. Mailing address: 3540 Akula Dr. Anchors State: AK Zip99516 City: Anchorage 9 . ___ S#A4Y Phone number: ( 907 ) 345 - 0593 fax:345-4700 ` S 3 p .. q gf c Drillers signature: • Alaska state law requires that a copy of this well log be sent to the Within the City of Anchorage, it is required that a copy of the well log be Department of Natural Resources within 45 days: faxes arc sent to the appropriate city office within 60 days and that another copy of acceptable. (AK statutes 38.05.020.38.05.035.41.08.020. the well log be sent to the well property owner within 30 days. 46.15.020 and AK regulations 11 AAC 93.1 10). Permit Number:OSP13168 _-----_ DNR/Division of Mining.1a020 d Water. Date of Issue: Oct i 11 i 2-013 550 W 7th Avenue,Suite Anchorage,AK 99501- 3562 Parcel Identification Number: - - Phone(907)269-8639 and fax(907)269-8947 Is well located at approved permit location?( x)Yes or ( )No Development Services Department Building Safety Division • 41'.,t On-Site Water & Wastewater Program 4700 Elmore Road P.O. Box 196650 < I Mark Begich Anchorage, AK 99507 s F r. T Y • Mayor www.muni.org/onsite (907)343-7904 Pump Installation Log Well Drilling Permit Number: 051, Date of Issue: it)_ 11- l 3 Parcel Identification Number: Legal Description 9 c r X jai tit) Property Owner Name&Address: r�tCca inn 5 166 b6 91 )4 '/, I r4 t tore 1, Pump Installation Date: I u— — 19 Pump Intake Depth Below Top of Well Casing: gig feet Pump Manufacturer's Name: GoiAl 6/ 5 Pump Model: 11 `7 V, P1A-.ld Pump Size 11.; hp Pitless Adapter Burial Depth: 8 feet Pitless Adapter Manufacturer's Name: b- 10 Pitless Adapter Installer: 1.✓i i CA) Well Disinfected Upon Completion? ( Yes 17 No Method of Disinfection: CA,1ar,ti '-'c,6s Comments: Pump Installer Name: cjo yl" � Hefty P.O.BoZ112130 Anchorage,AK99511 Attention: The pump installer shall provide a pump installation log to the DSD within 30 days of pump installation. t2Ci-_SUL H 65H L32H SGS Ref.# 1184738001 Client Name Residential Testing-Cash Account Printed Date/Time 08/30/2018 16:50 Project Name/# George Heim Collected Date/Time 08/24/2018 10:00 Client Sample ID Shower Received Date/Time 08/24/2018 12:54 Matrix Drinking Water Technical Director Stephen C.Ede Sample Remarks: Allowable Piep Analysis Parameter Results LOQ Units Method Container ID Limits Date Date Init Metals by ICP/MS Arsenic ND 5.00 ug/L EP200.8 C (<10) 08/28/18 08/29/18 DSH Waters Department Total Nitrate/Nitrite-N ND 0.100 mg/L SM21 4500NO3-F B (<10) 08/27/18 AYC Microbiology Laboratory E.Coli Negative 1 100mL SM21 9223B A 08/24/18 K.W Total Coliform Negative 1 100mL SM21 9223B A 08/24/18 K.W 2 of 5 Permit Number: Tax Code Number: Work Type: On-Site Water & Wastewater System Permit OSP121342 02055150000 WellSeptic MUNICIPALITY OF ANCHORAGE Development Services Depadment On-Site Water & Wastewater Program 4700 Elmore Road, PO Box 196650 Anchorage, AK 99519-6650 Telephone: (907) 343-7904 Renewal Permit Effective Dates: October 09, 2012 to October 09, 2013 Design Engineer: ANDERSON ENGINEERING Subdivision: RABBIT CREEK VIEW & HEIGHTS Site LegalAddress: RABBIT CREEKVIEW & HEIGHTS BLK 5H LT 32A G:3340 Owner/Address: TUCKER PATRICIA A AKA HElM PATRICIA A 16600 OLSON CIR ANCHORAGE AK 995165526 Site Mailing Address: 16600 OLSON CIR, Anchorage Lot Size in Sq Ft: 26813 Total Bedrooms: 1 This permit is for the construction of: N Disposal Field N Septic Tank Y Holding Tank N Privy Y Private Well N Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80). 3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either: A. Open and Close on the same day. B. Covered, sealed, and heated to prevent freezing. MUNICIPALITY OF ANCHORAGE Community Development Depadment Development Services Division On-Site Water & Wastewater Program ~"' Phone: 907-343-7904 Fax: 907-343-7997 ON-SITE SEWER/WELL PERMIT APPLICATION Legal description (Sub'd., Block & Lot) L~ ~- Legal description (Township, Range & Section) Lot Size ,~.~ ~!. ,~/-~ Sq. Ft. Number of Bedrooms APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: ([~ all that apply) Absorption Field [] Initial [] Single Family (SF) (w/wo ADU) Septic Tank [] Upgrade [] Duplex (D). Holding Tank ' [] Renewal [] Multiple Dwellings Privy [] (SF and/or D) Private Well [] ~ ¢~ ,~.,.~,,. ~ ,~ Water Storage [] ./2~,-/v~',4 THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit/Rush Fees: I'~O ~ I~.~r'¢_.co~.- Waiver Fees: Date of Payment: 11;b I t ~ I ~ Date of Payment: Receipt Number: 0~'o2JI ~ Receipt Ndmber: PermitNo. O~¢J~t~'~-~,~-- WaiverNo. Permit App_9-1-12.doc Permit Number: Tax Code Number: Work Type: On-Site Water & Wastewater System Permit OSPl11288 02055150000 WellSeptic MUNICIPALITY OF ANCHORAGE Development Services Department On-Site Water & Wastewater Program 4700 Elmore Road, PO Box 196650 Anchorage, AK 99519-6650 Telephone: (907) 343-7904 Renewal Permit Effective Dates: October 11,2011 te October 10, 2012 Design Engineer: ANDERSON ENGINEERrNG Subdivision: RABBIT CREEK VIEW & HEIGHTS Site LegalAddress: RABBIT CREEK VIEW & HEIGHTS BLK 5H LT 32A G:3340 Owner/Address: TUCKER PATRICIA A AKA HElM PATRICIA A PO BOX 2183 SEWARD AK 996642183 Site Mailing Address: 16600 OLSON ClR, Anchorage Lot Size in Sq Ft: Total Bedrooms: 26813 1 This permit is for the construction of: N Disposal Field N SepticTank Y Holding Tank N Privy N Private Well N Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80). 3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either: A. Open and Close on the same day. B. Covered, sealed, and heated to prevent freezing. Received By: ~ ~--~'~ ~~---'% Date: ~'- ~ ":/-/~ ~-.----' MUNICIPALITY OF ANCHORAGE Community Development Department Development Services Division On-Site Water & Wastewater Program Mayor Dan Sullivan Phone: 907-343-7904 Fax: 907-343-7997 ON-SITE SEWER/WELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Parcel I.D. O '~h. ~ ~-~ ~-'/.~-~ O Pr°perty°wner(s)-'-it-L" c/k'e P ~ f~ ,c, /;~ /~ Dayphone Site address / (~ (~ O o 0 /~o~ (",i~, ~,~ ~, Legal description (S~b'd., Block & Lot) ~,, ~4t' ~ C ~'/< L/, ~'_~.~ Legal description (Township, Range & Section) Lot Size ~ ~¢/~ Sq. Ft. Number of Bedrooms / THIS APPLICATION IS FOR: ([~ all that apply) THIS APPLICATION IS AN: Absorption Field ~' Initial Septic Tank ~ Upgrade [] Holding Tank ~ Renewal [] Privy [] Private Well Water Storage [] THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR: I certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit/Rush Fees:. / ~ O ~./~' ./~/~t~,..Waiver Fees: Date of Payment: _/LO · ¢-'- j j Date of Payment: Receipt Number:. (~ ~) '~ O ~ (.. Receipt Number: Permit No. ('~ ~ P I I/? ~ Waiver No. G:\Building\On Site\Forms\Clien~ Forms\Permit App_010411 .doc (Rev. 1/11) ANDERSON ENGINEERING P.O. BOX 240773 ,ANCHORAGE, AK 99524 522-7773 677-7766 (FAX) MEMORANDUM DATE: October 11,2011 TO: Deb Wockenfuss FROM: Mike Anderson, P.E. SUBJECT: Lot 32A, Block 5H, Rabbit Creek Heights Subdivision Septic System Construction Permit No. OSP101229 The holding tank septic system originally designed for this lot is still appropriate at this time. No changes have been noted in the area which would preclude construction of the holding tank. (,,~)¢.-,,~.~ ~¢,--~o,~ "f; 5'~¢,-- Permit Number: Tax Code Number: Work Type: On-Site Water & Wastewater System Permit OSP101229 02055150000 WellSeptic MUNICIPALITY OF ANCHORAGE Development Services Department On-Site Water & Wastewater Program 4700 Elmore Road, PO Box 196650 Anchorage, AK 99519-6650 Telephone: (907) 343-7904 Renewal Permit Effective Dates: October 11, 2010 to October 11, 2011 Design Engineer: ANDERSON ENGINEERING Subdivision: RABBIT CREEK VIEW & HEIGHTS Site Legal Address: RABBIT CREEKVIEW & HEIGHTS BLK 5H LT 32A G:3340 Owner/Address: TUCKER PATRICIA A AKA HElM PATRICIA A PO BOX 2183 SEWARD AK 996642183 Site Mailing Address: 16600 OLSON CIR, Anchorage Lot Size in Sq Ft: 26813 Total Bedrooms: 1 This permit is for the construction of: N Disposal Field N Septic Tank Y Holding Tank N Privy Y Private Well N Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80). 3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either: A. Open and Close on the same day. B. Covered, sealed, and heated to prevent freezing. Received By: Date: Date: ~ ~,!/'~(~ Municipality of Anchorage Development Services Department Building Safety Division On-Site Water and Wastewater Program 4700 EImore Road P.O. Box 196650 Anchorage, Alaska 99507 www.muni.org/onsite (907) 343-7904 ON-SITE SEWER/VVELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Prope~yowner(s~;~ ~. ~, ~ Dayphone Site address Legal description (Sub'd.. Block & Lot) Legal de,cri,tion (Township. R,nge * Se*ion) Lot Size THIS APPLICATION IS FOR ([~ apl that apply): THIS APPLICATION IS AN: Absorption Field ~"~' Initial ~ Septic Tank ~ Upgrade ~ HoMing Tank [] Renewal [] Privy [] Private Well ~ Water Storage [] I certify that the above information is correct. I further certify that this application is being made for a Single F~lling and is in accordance with applicab, le Municipal Codes. (Signature of property owner or authorized agent) Permit/Rush Fees: Date of Payment: Receipt Number: (Rev. 11/05) Waiver Fees: Date of Payment: Receipt Number: MUNICIPALITY OF ANCHORAGE Development Services Department On-Site Water & Wastewater Program 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM /WATER SUPPLY PERMIT Initial Date Issued: Oct 06, 2009 Expiration Date: Oct 06, 2010 Permit Number: SW090201 Legal Description: RABBIT CREEK HEIGHTS BLK 5H LT 32A Design Engineer: 0014 ANDERSON ENGINEERING Owner Name: PATRICIA A. HElM Owner Address: 16600 OLSON CIR ANCHORAGE , A 99516- ParcellD: 020-551-50 Site Address: 16600 OLSON CIR Lot Size: 26813 SQ. FT. Total Bedrooms: 1 Permit Bedrooms: 1 This permit is for the construction of: [] Disposal Field [] Septic Tank [] Holding Tank [] Privy [] Private Well [] Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ). 3. The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. 5. The following special provisions. Received By: ~ Issued BY~/~/'~ ,'I Date: Date: Municipality of Anchorage Development Services Department Building Safety Division On-Site Water and Wastewater Program 4700 Bragaw Street P.O. Box 196650 Anchorage, Alaska 99519-6650 www.muni.org/onsite (907) 343-7904 ON-SITE SEWER/WELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Parcel I.D. 020-551-50 Property owner(s). Patdcia A. Helm Mailing address 16600 OIson Circle Anchorage, AK Site address 16600 Olson Circle Anchorage, AK Day phone .Zip Code 99516 Zip Code 99516 Legal description (Sub'd., Block & Lot) Lot 32A, Block 5H, Rabbit Creek Heights Subdivision Legal description (Township, Range & Section) Lot Size 26,813 .Sq. Ft. Number of Bedrooms One (1) THIS APPLICATION IS FOR ([~ all that apply): THIS APPLICATION IS AN: Absorption Field [] Initial Septic Tank [] Upgrade Holding Tank [] Renewal Privy [] Private Well [] Water Storage [] I certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit/Rush Fees: Date of Payment: Receipt Number: (Rev. 11/05) Waiver Fees: Date of Payment: Receipt Number: June 15, 2009 Municipality of Anchorage Development Services Department On-Site Water and Wastewater Program 4700 South Bragaw Street Anchorage, AK 99519-6650 Subject: Lot 32A, Block 5H, Rabbit Creek Heights Subdivision Septic System Design and Permit Application Impacts to Adjacent Properties Dear Onsite Services Engineer: The soil conditions on Lot 32, Block 5, Rabbit Creek Heights Subdivision will not support placement of a conventional or high tech septic system due to high groundwater and the presence of adamant subsurface soils. We are therefore proposing to place a new 2,000-gallon steel holding tank to serve the one-bedroom home on the lot. We are requesting a permit be issued for the construction of a new well and holding tank to serve the home. The house has been on the lot since the 1950s and is currently served by a porta potty. Potable water is hauled to the home for use. The attached Site Plan and backup documentation identify the location and configuration of the proposed location the well and holding tank. Also identified on the plans are the locations of wells and septic systems on adjacent lots. Many undocumented systems are in operation in the area, but none will impact placement of a well or holding tank on this lot. Drainage patterns and ground surface slopes are shown on the Site Plan. The drainage patterns will be maintained after construction. Test holes on the lot revealed peat to depths of 3' underlain by highly plastic tight blue silt with claylike features. This material will not absorb water. The groundwater level is at or above the interface between the peat and the silt layer. An absorption type septic system cannot be placed on the lot. Test hole logs are attached which verify the subsurface soils condition. The ground surface on the lot slopes at shallow grades to the northeast. The new septic tank will be constructed near the location of the existing tank and as parallel with the slope of the land as possible in conformance with Municipal requirements. Lot 32A, Block 5H, Rabbit Creek Heights June 15, 2009 Page 2 of 2 If the tank is constructed in accordance with our design the following statements apply: The tank, if constructed as designed, will have no adverse impact on the wells in the area or those to be constructed in the future. The tank, if constructed as designed, will have no adverse impact on existing septic systems in the area or those to be constructed in the future. The tank, if constructed as designed, will have no adverse impact on reserve space, either surface or subsurface, on any lots located in the area. The tank, if constructed as designed, will have no adverse impact on drainage patterns in the area. The current drainage pattern will be maintained. Sincerely, Michael E. Anderson, P.E. Attachments MICHAEL ~, ANdeRSON .,_= · ~-. · AREA MAP ~,~b.~r,s..~ ~.. ~ ..... SCALE ~* = RABBIT LOT CREEK HEIGHTS 32A, BLOCK 5H 25,674- S.F. IX,,, \ 2.000 G<~llon Heldlng Tonk Pump Truck x, SiTE PLAN SCALE 1' = 40' LEGEND PV - 6" Pump Vent AV - Alarm Vent MH - Manhole FCO- Foundation Cleanout HOLDING TANK SEPTIC SYSTEM LOT 32A, BLOCK 5H RABBIT CREEK HEIGHTS SUBDIVISION /~6" Pump Out Riser 4' Min, Cover Eye Bolts Every 2' 1/2" Cable with Turnbuckle Tight Over Tank 10'Lx2.5'W x 2.5' Deep Concrete Ballast ,~.' 10' Lx2.5'W x 2.5' Deep Concrete Ballast Construct Orenco Systems Inc. Sentinel 1 or Sentinel II Liquid Level Alarm. Place High Level Alarm Panel at House. Minimum Holding Tank Capacity 2,000 Gallons. ELEVATION VIEW No Scale 03/03/2009 10.' 20 3491934 WATKINS ENGR PAGE Municipality of Anchorage ~''~'/' \  Development Services Department Building Safety Division Or. Site Water and Wastewater Program P.O, Box 196650 Anchorage, AK 99519-6650 www.munL o~g/on~ite · (907) 343-7904 Sods Log - Percolation Test Performed For: Legal Description: 1 2- Patti Heim Da~e Performed: Dec, 5, 2003 Rabbit Creek Heights, Block 5, Lot 32 Township, Range, Section: NA Slte PIan 9- 10- I1- 12- 13- 14. 15- 20- 7'-H e t /k WAS GROUND WATER ENCOUNTERED? YES IF YES, AT WHAT DEPTH? 3,~ L Depth lo Water After o P Monitoring? NA e 0a~e: NA Reading Dale Gross Time Nel Time Depth to Waist Net Drop TH#1 PERCOLATION RATE {mlnula¢inchl PRRo HOLE DIAMETER TEST RUN BETWEEN FT AN~3 FT PERFORMED BY; Cindy W. EI,i,, P,S, I (.' ~ *~'/~ ;~/~ (- ' ~ L ~'~-" CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE ANO MUNICIPAL OUIDEL?.)~IE$ iN EFFECT ON THiS DATE, DATE: i~:ZU ~U1U~ W~KIN~ EN~ PAaE 12 Municipality of Anchorage ~,~"~ ~  Development Services Department I ~'~.-! '-~ I_~. ~ ~3'.~ On-Site Wa~ and Wasmt~ P~mm I ~ ~' ~?~"E 4700 ~ 8m~W SL I · ~[ --. -~~--,~'~ Soils Log - Percolation Test [ ~ PedDled Fo~ Patti Helm Pat= Peffo~ad: Dec. 5. ~03 Legal Oes~ptlon: Rabbit Creek Height, BIo~ 5, Lot 32 T~ship, Ren~, ~on: ~ 6. 7- 8- 9- 10- 11- 12- Site Plan WAS GROUND WATER ENCOUNTERED? YES IF ¥E$i AT WHAT DEPTH? 3.0 L Date: 12-17-03 14- 15- 16- 17- 18- 19- 20- COMMENTS NO pera le.~ performed. Reading Date Gross '~me Net Time Depth to Water Ne! Dm3 TH#2 / PERFORMED BY; Cindy W. Elli.% I=,E. I ~ ~ CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAl. GUIDELINES IN EFFECT ON THIS DATE, DATE; ./~_..-,/~ Holding Tanks Page 1 of 1 Features: · Constructed to the requirements of the Uniform Plumbiqg Code and UL®58 steel thickness. . Watertight manholes prevent seeping of groundwater. · Adjustable float levels. · Orenco Systems, Inc. Sentinel I (115 volt) or Sentinel II (battery) liquid level alarm. · Coated inside and out with coal tar pitch. · Dimensions and weights are approximate. · Approved by the State of Alaska DEC and the Municipality of Anchorage. IM nchorage Tank Approx. Number Gallons AT1000H 1,000 AT1500H 1,500 AT2000H* 2,000 AT2500H 2,500 AT3000H 3,000 AT4000H* 4,000 Steel Diam. Length (feetI I[ Gauge II(,nchee)(A)[[ (B) II 12 II 58 8 II 3/16 II 58 12 II 3/16 ii 64 12 II 3/16 II 64 15 II 3/16 II 78 13 II 3/16 II 76 17 Inlet Invert (c) Shipping Weight (LBS) 51-1/2" 834 51-1/2" 57" 57" I I 68-1/2" 1,409 1,984 2,672 2,564 I II 68-1/2" 3,187 I *Typically in stock. ON-SITE WASTEWATER DISPOSAL SYSTEM CONSTRUCTION AND MATERIAL SPECIFICATIONS SUBJECT: LOT 32A, BLOCK 5H, RABBIT CREEK HEIGHTS SUBDIVISION GENERAL: The scope of this project includes the procurement and placement of a new 2,000-gallon holding tank at the location shown on the Site Plan. Work also includes the placement concrete ballast to offset the flotation of the tank due to high groundwater. Additional work includes the placement of a high level alarm system. The new holding tank must be placed 100' from the proposed well on the lot and 100' from all private wells and any surface water in the area and 10' from the water service line from the well. A minimum of 4' of cover is required over the holding tank. A foundation cleanout must be placed a maximum of 2' from the house foundation. Construction shall be in accordance with the approved site plan, design drawings, Municipal Permit with any special provisions or conditions, and all applicable State and Municipal Wastewater Disposal Regulations. The Contractor shall be responsible for obtaining all underground utility locates and for the layout of the septic system and verification of the location of all lot lines. The Contractor must also verify the location of wells in the area and assure that the separation distances are met. Unless specifically agreed otherwise, the contractor shall be responsible for final grading areas subsequently depressed from soil settling. Property owner shall be responsible for revegetation of affected areas unless specifically agreed otherwise. Contractors installing wastewater disposal systems must be certified by the Municipal Development Services Department Building Safety Division On-Site Water and Wastewater Program for system installations. Owners installing their own systems must receive prior approval from the On-Site Water and Wastewater Program before beginning system installation. HOLDING TANK INSTALLATION A new 2,000-gallon holding tank must be procured from an approved source and installed at the location shown. It must conform to the corrosion prevention standards for septic tanks under the Uniform Plumbing Code as amended. 2. A holding tank is to be constructed by a certified septic tank manufacturer. Construction shall include a 20" watertight manhole to provide access to the Lot 32A, Block 5H, Rabbit Creek Heights June 15, 2009 Page 2 of 3 interior of the tank. It must also have a 6" diameter standpipe that extends 12" above the ground surface for pumping access. 3. The holding tank shall be sufficiently bedded to prevent settling or shifting of the tank. 4. All standpipes on the holding tank shall extend a minimum of 12 inches above final grade. 5. Tanks installed without 4' of cover shall have a minimum of 2" of direct burial insulation. 6. A foundation cleanout shall be installed one to four feet from the building foundation. 7. Final grading over the tank shall be such that a positive slope exists away from the holding tank. The holding tank must be equipped with an approved high level alarm which registers both visually and audibly inside the dwelling. The alarm must be positioned to allow at least 150 gallons per bedroom of additional storage but not less than 300 gallons after the alarm has been activated. MATERIAL SPECIFICATIONS: 1. Holding tanks must be constructed by a municipally approved holding tank manufacturer. 2. The following pipe materials are approved for use in septic system installations in the Municipality of Anchorage: Cast Iron (perforated and solid), ASTM D3034 or P.V.C. (perforated and solid), ASTM F810 or H.D.P.E. (perforated, but not solid) and ASTM D2662 or A.B.S. (perforated and solid). 3. Insulation shall be at least 2" thick extruded direct burial polystyrene (Dow Chemical Co. Styrofoam HI or equal). 4. Septic tank inlets and outlets shall be fitted with watertight couplings (Caulder, Fernco, or equal). 5. A permeable geotextile fabric (Typar, Mirafi or equal) must be installed between the final drain rock layer and the native soil layer. Lot 32A, Block 5H, Rabbit Creek Heights June 15, 2009 Page 3 of 3 6. All drain rock shall be .5" to 2.5" in diameter with less than 3% passing the #200 sieve. INSPECTIONS: Municipal Ordinance requires a minimum of two inspections. These inspections must be conducted under the supervision of a professional engineer registered in the State of Alaska. The first inspection must be conducted after the excavation of trenches, beds or pits and before the installation of any gravel. A holding tank may be set in place, but may not be backfilled. The second inspection must be conducted after the placement of the geotextile fabric, gravel, distribution piping, standpipes, cleanouts and insulation. No backfill should be in place at the time of inspection. Contractor shall provide a copy of all field survey layout and construction notes for use in preparing the certified as-built of the completed system. ~w, un i~ei baimon Locge FAX NO. : Oc'~. 01 -~OO9 ll:~SAf~ P2 Munici,pali .ty of Anchorage Mayor Dan Sullivan Planning Department September 16, 2009 Patricia A. l'ucker-Heim P.O. Box 2183 Seward, AK 99664 Dear Ms. Tucker-Helm: This letter is in response to your request for a determination of the nonconforming status of the property located at 16600 Olson Circle. (ParceI: 020-551-50, Grid: SW3340) This determination is based upon the as-built survey provided with your request, building permit records, tax assessment records, our research, and the applicable Municipal Ordinances in place presently and at the time of construction. The following facts were established: · Rabbit Creek Heights Block 5H, Lot 32A was created by plat 04-91, filed April 2, 2004. The plat was approved by final judgment by the Alaska Superior Court case 3AN-98-11718 and recorded on Serial No. 2004-022267-0, Anchorage Recording District on April 2, 2004. · April 3, 1984 the property was zoned R-7, intermediate rural district. · Municipal property appraisal records (CAMA) currently indicate a 26,813 square foot lot (other improvements). · Municipal property inventory sheets indicate the following: · April 11, 1979 interior picked up house due to being in livable condition and is being lived in. · August 27, 1990 vacant, no change. · July 22, 1976 building permit number L-3045-76 issued for a 16'x18' cabin. · An as-built survey by Lantech dated March 29, 1992 shows one story house on wood block foundation. · May 19, 1974 aerial photo (flight 15, frames 9 & 10) shows vacant land. · October 10, 1977 aerial photo (flight 10, frames 7 & 8) shows a small structure with a front deck very close to the road. · June 22, 1983 aerial photo (flight 11A, frames 8 & 9) shows the structure with a front deck and an addition to the south. . September 21, 1985 aedal photo (flight 10A, frames 8 & 9) shows the structure with a new roof and a small addition in the rear. bK~dM :~ec~ Salmon L~¢,9~ FAX NO. : Oat. 01 ~009 ll:36AM F3 Nonconforming Status determination Rabbit Creek Heights, Block 5H, Lot 32A Page 2 Anchorage Municipal Code (AMC) provisians relevant to this determination are as follows: AMC 21.40.090(F)('1 ) Minimum lot requirements: A minimum lot size of 20,000 square feet, and a lot width of 120 feet for a single- family dwelling, AMC 21.40.090(G) Minimum yard requirements: 1. Front yard: 25 feet. See supplementary district regulations for additional setback requirements. 2. Side yard: Ten feet. 3. Rear yard: 20 feet. AMC 21.40.090(H) Maximum lot coverage: Maximum lot coverage by all buildings is 30 percent. AMC 21~45_.030(A) provides that: "No accessory building shall be erected or maintained in any required yard, except that: 1. buildings accessory to a residential use may be erected in a requirea rear yard which is adjacent to an alley; and 2. sheds of 150 square feet or less and not attached to a foundation may be erected in a required side or rear yard." AMC 21.45.030(B) provides that: "No separate accessory building shall be erected closer than ten feet to any principal structure on the lot or an abutting Jot or tract." The following conclusions are drawn from the above information: The lot has the minimum area and width required by the R-7 district. Therefore, subject lot is a conforming lot of record. The cabin encroaches 24.3 and 20.8 feet into the required 25 foot front yard setback. Since it predates zoning, the cabin is a Legal Nonconforming Structure and is governed by AMC .2!..55_.040. The small addition at the rear of the structure encroaches into the required 25 foot front yard setback. The addition is an expansion of a nonconforming structure. Since it does not predate zoning, the addition is not a Le,qal Nonconforming Structure and is in violation of AMC 21.40.090 and AMC 21.55.040. The violation may be remedied by removing the addition or obtaining a variance from the Zoning Board of Examiners and Appeals. Pursuant to AMC 21.55.040.A Nonconforming Structures states: 1. No such nonconforming structure may be enlarged or altered in a way that increases its nonconformity, but any structure or portion thereof may be altered to decrease its nonconformity. 4. A residential structure in a residential zone may be enlarged, so long as the addition to the structure conforms to all the requirements set forth in this title. rmUl'l .~:co ~o:rnon LC, C,_--~e FFt>< NO. : Oct. (~1 2009 11:3E,~i~ F'4 Nonconforming Status determination Rabbit Creek Heights, Block 5H, Lot 32A Page 3 The shed encroaches 17 feet into the required 25 foot front yard setback. Since it does not predate zoning, the shed is not a Leqal Nonconformin,q Structure and is in violation o[ AMC 21.40,090 and AMC 21.45.030. The violation may be remedied by removing the shed, moving the shed to a conforming location or obtaining a variance from the Zoning Board of Examiners and Appeals. The stairs encroaches into the right-of-way of Olson Circle, and are in violation of AMC 24.313,020. This violation can be remedied by obtaining an encroachment permit from the Department of Development Services, Right.of-Way division. This office is located at 4700 Elmore Road. The telephone number is 343-8240. Note: This determination is based on the information listed above, which was provided by the applicant or was in the flies of the administrative official, If additional information is obtained, or the infom~ation provided above is later determined to be inaccurate or false, and materially changes the conclusion herein, the administrative official may revise or revoke this determination. Anchorage Municipal Code Title 21 is available on the internet http://www.municode,com. If I can be of furlher assistance, please contact me at 343-8380. at Respectfully, Land~ rr-.uri .:yea :7..8.!mon Loc.:e FAX Nu. . Qc'. 31 2009 11:3`:Ar F2 - Municipality of Anchorage • � 1r �.e _ — — ..,,_.... . . i r.O.Box 19650• .4nchnrage,Alaska 995;9-6650-Telephone:(907)343-7909• Fax:(907)34:i-792' -- Plwsicai Address 4700 Elmore Road• Agnchoraee.Alaska 995(1'•htry://N-.vw".mvni.ore!nknnine Mayor Dan Sullivan PIanning Department September 16, 2009 Patricia A. Tucker-Heim P.O. Box 2183 Seward, AK 99664 Dear Ms. Tucker-Heim: This letter is in response to your request for a determination of the nonconforming status of the property located at 16600 Olson Circle. (Parcel: 020-551-50, Grid: SW3340) This determination is based upon the as-built survey provided with your request, building permit records, tax assessment records, our research, and the applicable Municipal Ordinances in place presently and at the time of construction. The following facts were established: • Rabbit Creek Heights Block 5H, Lot 32A was created by plat 04-91, filed April 2, 2004. The plat was approved by final judgment by the Alaska Superior Court case 3AN-98-11718 and recorded on Serial No. 2004-022267-0, Anchorage Recording District on April 2, 2004. • April 3, 1984 the property was zoned R-7, intermediate rural district. • Municipal property appraisal records (CAMA) currently indicate a 26,813 square foot lot (other improvements). • Municipal property inventory sheets indicate the following: • April 11, 1979 interior picked up house due to being in livable condition and is being lived in. • August 27, 1990 vacant, no change. • July 22, 1976 building permit number L-3045-76 issued for a 16'x18' cabin. • An as-built survey by Lantech dated March 29, 1992 shows one story house on wood block foundation. • May 19, 1974 aerial photo (flight 15, frames 9 & 10) shows vacant land. • October 10, 1977 aerial photo (flight 10, frames 7 & 8) shows a small structure with a front deck very close to the road. • June 22, 1983 aerial photo (flight 11A, frames 8 & 9) shows the structure with a front deck and an addition to the south. • September 21, 1985 aerial photo (flight 10A, frames 8 & 9) shows the structure with a new roof and a small addition in the rear. r r.ur i .mea a 1 more LOC=ee FAX NO. Oct.. 01 2009 11: E.Ar' F4 Nonconforming Status determination Page 3 Rabbit Creek Heights, Block 5H, Lot 32A The shed encroaches 17 feet into the required 25 foot front yard setback. Since it does not predate zoning, the shed is not a Legal Nonconforming Structure and is in violation of AMC 21.40.090 and AMC 21.45.030. The violation may be remedied by removing the shed, moving the shed to a conforming location or obtaining a variance from the Zoning Board of Examiners and Appeals. The stairs encroaches into the right-of-way of Olson Circle, and are in violation of AMC 24.30.020. This violation can be remedied by obtaining an encroachment permit from the Department of Development Services, Right-of-Way division. This office is located at 4700 Elmore Road. The telephone number is 343-8240. Note: This determination is based on the information listed above, which was provided by the applicant or was in the files of the administrative official. If additional information is obtained, or the information provided above is later determined to be inaccurate or false, and materially changes the conclusion herein, the administrative official may revise or revoke this determination. Anchorage Municipal Code Title 21 is available on the Internet at http://www.municode.com. If I can be of further assistance, please contact me at 343-8380. Respectfully, ilk lor. Th4y)),1 Land Use Plan Reviewe - --�,- lO/Co/oq Per iv'vh & Coe 4./ke 0.14 r (A41 I , . V • et WI Q IM, 4,k "1,1 are vtd ���1. TO e" I AP' a / I a?le o Gev,e 'i0? + SUBJECT 3Q. SLK5.7 C/.1 #71g. p DATE APg MESSAGE 'rue 7 /AR bi/u6 eJ ded-vt-A- /gage_ ctrkv a-stal "eetl-e..-V 1242 eUt) il-W/44.L4142,1, SIGNED --.64424.11AJ REPLY getLaAj _ t SIGNED DATE / SEND PARTS 1 AND 3 WITH CARBON INTACT- PART 3 WILL RE RETURNED WITH REPLY. Redifirme 4S 472 Poly Pok ISO 4P472 •