Press Alt + R to read the document text or Alt + P to download or print.
This document contains no pages.
HomeMy WebLinkAboutRABBIT CREEK VIEW & HEIGHTS BLK 9H LTS 13A & 14ARabbit Creek
View & Heights
Block 9H
Lot 13A & 14A
#020 - 581 - 29
MUNICIPALITY OF ANCHORAGE
On -Site Water & Wastewater Program
PO Box 196650 4700 Elmore Road
Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997
http:/Avww.muni.org/onsite
Onsite Wastewater Disposal System Permit
Permit Number: OSP201506
Work Type: Septic Upgrade
Effective Date:
Exppration Date:
Tax Code Number: 02058173000
Site Legal Address: RABBIT CREEK VIEW & HEIGHTS BLK 9H LTS 13A & 14A G:3341
Site Mailing Address: 16861 NICKLEEN ST, Anchorage
Owner: MAIER ROSS & MELINDA
Design Engineer: GARNESS ENGINEERING GROUP LTD
This permit is for the construction of:
❑ Disposal Field © Septic Tank ❑ Holding Tank ❑ Privy
prnr
cpartment
12/31/2020
12/31/2021
Lot Size in Sq Ft: 44678
Total Bedrooms: 6
❑ Private Well ❑ Water Storage
All construction shall be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80)
3. The wastewater code requires inspections during the installation. The engineer shall notify the Development
Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
shall be either:
a. Opened and Closed on the same day, or
b. Covered, sealed, and heated to prevent freezing
Special Provisions: This permit is for the replacement of the septic tank only. If the drainfield does not recover,
as anticipated, a change order shall be submitted to add the rebuild of the drainfiield to the scope of the permit.
Received By: Date:
Issued By: e6&2ta Date: /2 3/ o7Ua0
000 000 000 000 000 000 oao ooa oLL Soa o00 000 00o Q�W'oimi ► §W %
§.r
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP201506, Rebecca Carroll, 12/31/20
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP201506, Rebecca Carroll, 12/31/20
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP201506, Rebecca Carroll, 12/31/20
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP201506, Rebecca Carroll, 12/31/20
ALASKA
(9o~)
enUlRonmenTAL CONTROL Si RUICES,
~n~incerincI ~ (~nuir'unmcnlal Studies
P. 0. Box 240668
Anchorage. AK 99524-0668
279-5553 *** FAX (907) 276-8706
inc.
September 20, 1990
Municipality of Anchorage
Department of Health & Human Services
825 L Street, Fifth Floor
Anchorage, AK 99501
Lots 18 & 14, Block 9, Rabbit Creek Heights Subdivision
Peat Mound
This report is supplemental to the On-Site Section report,
and the attached as-built drawings. It is shown in red on
the as-built how modifications were made to the design.
When the construction initially started the secondary field
was first installed, generally in the same configuration as
shown on the deslgn drawings. Several of the trees that we
intended to save
system Installed.
We did note that
over peaty type soil.
are not spots in the
approaches four feet
had to be removed in order to get the
The secondary system is over good soil.
the northern part of the secondary bed was
We checked the water table, and there
bed In whlch the water table
below the disposal field.
There were some slight changes made to the design of the
peat bed, When they opened the field up for removal of the
old sand and gravel that had been placed over the original
visqueen liner, we found that there had apparently been
enough cement in the sand and brick to cement it into a
relatively hard rock. The contractor graded it and placed a
small amount of material over it to smooth lt. The new
layer of visqueen was then placed on top of this old
collection system. Instead of a foot of rock we only used 9
inches. The intent of the rock was for a collection vehicle
and not as a waste treatment vehicle, so the rock was
reduced to 9 inches. Eighteen inches of sand was then
placed on top of the rock, This is a clean pit-run eand
from the Lake Otis sand and gravel pit. The peat, ae it was
being removed from the original bed, was segregated into the
peat had been contaminated with fill material, and the
clean peat. This clean peat was placed in accordance with
the drawinga. The contractor substituted 1-1/4 inch
laterals instead of the I inch laterals. All holes and
configurations were as originally shown on the design
documents. The net effect of the larger pipe would be to
somewhat reduce our head loss, thereby giving more available
head at the pump system. Once the pipes were in place in
the peat the Beauty Bark was placed in the excavated holes.
The Beauty Bark is to break up the flow from the laterals.
There ~as an original distribution pipe that came into the
bed that had been disconnected by others. We reconnected
it, and moved it in slightly closer to the bed. The
contractor felt that insulation should be placed over it to
give it better protections. This was done. Upon having
everything in place, but before the peat cover was placed on
the pipes, the pump lift station was started to see how the
distribution plan would work. The water gently welled out
of the pipes and spread out across the peat. It appeared
that eventually there would be a complete saturation. The
size of the holes and spacing appeared to be more than
adequate. The pattern was even. Once this was done, the
contractor brought in several loads of milled peat to place
over the top of the distribution pipes. Only then did they
take the remnants of the old peat bed and place on top.
Some of this peat has been contaminated with gravel, brick
and rock. The home owners will probably remove the brick
before they start to reseed the bed. This contaminated peat
will not affect the system as it is well above the active
peat.
The contractor felt because of the drainage condition he
needed to bring in additional fill and regrade the ground to
ensure that water would not flow between the peat bed and
the secondary distribution system. He brought in a silty
sandy fill which was pushed out to build a terrace between
the two beds. He then ditched around so that the flow is to
the east-west and to the north-south along the lot lines.
On September 20, 1990, I again inspected the bed to see what
conditions where. Other than a few minor adjustments to the
grading, the system is in good shape. It appears to be
working properly.
In summary, I believe that this is a better peat bed than
the original one in that the sand underneath the peat Rill
ensure better quality bed effluent. The secondary bed will
then act only as a soil absorption system.
LCR/sr
8~:%) i Str'eet. :~nc:hcmage, ~.a~ka 99501
900 ~6 J U :)g -,acid,
C)Wi-~E~r i\la!T,'E~: CL.!I:;'TISS g, 3'UD'¢ BL.AKE
tJE*ITH.~H ACp;:fpE,~i;E~: I:;'_ u. BOX ]. 10285
AN~;FtORRGE;~, RI*.. 995 1 !
day
I.::'aplTE!! .~a2 O~:'.O-:Lii-4]
L.c¢_ L.eqa,~.~ Sub(::liv¢.sicu-I: RABBi'I CFd.EE]{ HEIGH'IS L..c:tt.'_.'
Sect :[ on: ] 7 o~,n~h ip: lin
!a),~ c-)cJpoom~;; This Pmr'mit~ 4 'D'Lai. .,apac~.'Ly~ 4
13 & .L4 B.Loc~::: 9
5Ezl f~ iANI M'i. rii...um Ll:z, tal]. septic tank ,z,~L~acit. v: 250 ,~4*t.LC~nEii.
leach s-~ept i t::
tani. (s) 4.0
'FHIS F:'E.I::,:F!Z'E l S ].SSUE;D F,']JR !'HE RECE)NSTI~LJCT'ION []F AN J. NNOVAI'J;VE.
DF AGREIEI"iE N'T f.41::Z'rWEE. N FHE OWNEEI~'.E~ AND DHHS ~4F~E I NCDRF'ORA'f'E:D [NTO
I I. i l.:::~ F'ISIRMI !,, I'[-}E ENGiNE:E:R MILL Noq'IFY DHHE 4,8 14(]LJRS iN ADVCM%II:;E
13f: RJqY 1..[[:)hJg;'ll-;.'.CJC'lJ;(]iq !I'-~E ;=IqL:JII',IEER WILL PROIVIDE DHHS W]:'rH A
t..;Ul'~J~ I'R(~I,] J ].(JJkJ ~[..;i'IE:.DUI._E ~L.) Il-iAi' )HHS MAY OBSERVE L]t.JNS] FdiC'] :.ON.
I CER] [F:Y FHA~:
¢(::)rth ~,¢ the Piun:~cic)al~.ty ot ~ncho~age (MDA) and the State c)~ Alaska,,
......~ ~i].., ins'Lall the system ~.n acc:o'dance w].'Ln a].] ~(.)A c:cmles and ecula'L:i.~ns.
~d]c~ ~.n cc~mplianc:e ~it..h the de~i~3g cr. it. eri~ of ~nzs
ALASKA eF1UIROFImE FITAL CORTROL $ RUICe$, linC.
(~ji~¢¢ri~(I ~ (~r~oironmcnlOI $1u(lies
(9o7)
P, 0. Box 240668
Anchorage, AK 99524-0668
279-5553 *** FAX (907) 276-8706
John Smith, P.H
Department of Health & Social
Municipality of Anchorage
825 L Street, Fifth Floor
Anchorage, AK 99501
June
Services
6, 1990
RE: Peat System: Lots 13-14, Block 9,
Rabbit Creek Heights Subdivision
Dear John:
Here is the design of the peat system upgrade.
use a pressure distribution system. Here are
points of the design.
I intend to
the salient
1. The pressure distribution system will use one-eighth
inch holes.
2. As rock is too heavy, I intend to place "Beauty Bark"
around each of the outlet points. This will keep the peat
away from the holes without settlement. It will also break
up the stream of effluent from the outlet.
3. If the Blakes are agreeable, I want to recycle some of
the liquid back into the septic tank to see if we can get
better nitrate removal. I've made a simple sketch of the
test sump.
4. The system will be
with the Maine studies
smaller. It will be more
by Dr. Rock at Orono.
in line
5. There will be 18 inches of the filtering sand under the
peat.
6. There will be 3 feet of peat to compensate for the
settling previously experienced.
7. I will develop a compaction testing schedule to bring
the density of the peat in line with Dr. Rock's work, i.e.,
6.1-7.4 #/ft$.
Please review the design, then issue a permit if you, have no
questions.
LCR/sr
Sincerely yours,
President
ALASKA ENVIRONI~TAL
CONTROL SERVICB~I INC.
1200 West 33rd Avenue, Suite B
.ANCHORAGE, ALASKA 99503
(907) 561-5040
JOB
SHEET NO OF
CHECKED BY DATE
$CAIF
Municipalily of Anchorage ~..: ,~1~1~"**~' ~'"j~.~.
DEPARTMENT OF HEALTH & HUMAN SERVI~~~-....~. ~
SOILS LOG -- PERCOLATION TES~. ~ C[~ ~ ~r.-
LEGAL DESCRIPTION: ~/y 4¢ ~--~,/~ ~ Township, Range. Section: / //~ ~
¢ ~ SLOPE SITE PLAN
1
2
3
4'
5
6
7
8
9-
10-
11
13
14
15
16
17,
18-
19-
20-
COMMENTS
WAS GROUND WATER ,~
ENCOUNTER ED~..~'~- ~
IF YES, AT WHAT
DEPTH?
Depth to Water After
Monitoring? Date:
Reading Date Gross Net Depth to Net
Time Time Water Drop
PERCOLATION RATE /5 (minutes/inch) PERC HOLE DIAMETER
TEST RUN BETWEEN 1~'~- FT AND / '~'~' FT
PERFORMED BY: L * /~'~ /,,/ I ~ CERTIFY THAT THIS TEST WAS PERFORMED iN
ACCORDANCE WITH ALL STATE AND MUN,CiPAL GUiDELiNES iN EFFECT ON THiS DATE. DATE: {~/~'/~ ~
72-008 (Rev. 4/85)
ALASKA ENVIRONI~kNTAL
CONTROL SERVICLI~IrlNC.
1200 West 33rd Avenue, Suite B
· ANCHORAGE, ALASKA 99503
(907) 561-5040
SHEET NO. OF
CHECKED BY CATE
SCALE
.! 5"'~,.,/~ ,c.~.¢,,-.~ ~ ./-, .
:'" '~ ~ : '"'~ ' '"" i"Y
~ ! ~ :'"'~'"'": ~ ,~ti~,:,,,,; '.,,-,,i,,,,,,,,~ ....
7' ~ 5 ~ ' / ~' .; . . .... L . . . .:. . ~ ..¢. ; ; :
,, ~.....;... :
~ , ,z~2%¢.¢ .: ...,......:......,....
f~...~ x ~~ ;
ALASKA ENVIRON ~kNTAL
CONTROL SERVICB~', INC.
1200 West 33rd Avenue, Suite B
ANCHORAGE, ALASKA 99503
(907) 561-5040
'~UNICIPALI~ ! OF ANCHOR~GE~
POUCH-6-650 ANCHORAGE, ALASKA 99502-0650
REPLY DATE FROM
91-008 (3/82)
DEPARTMENT OF HEALTH AND ENViRONMENTAl. PROTECTION
825 L GTREET, ANCHORAGE, AK 99501
264-472o
PERMIT Nil: 8'7;" I'78
DATE ISSUED: 07/20/8;'
APPL ~ C'.AN T:
AE ORES ....
CON1-AC'T' PHC)NE:
CUR-£]S AND SIGRID BLAKE
BOX 110285
ANCHORAGE. Al< 99511
545- 1.36~
LEGA_ DESCR!P: SUBDIVISION: RABBIT CREEK HEIGHTS LOT: 13&14
SECT!DN: ~ 'T'OWNSHIF': 11N ~NGE~ 3W
LOT ~I~.1=.. I.~o, ~ (SQ.F'T OR ACRES)
BLOC[{:
I cept. i£v that:
1, I am ~'am'J liar with the pequipements ~op on'-siz, e sewer~ and wells as set
Forth oy the Municioa!i{~ o~ Anchorage (MOA~ and the State o~ Alaska.
T~. I w~ I] instal1 the system :~n accopdanc~ with all MOA c:odes and Pequlations,
and in comp.fiance with the design cr'ite~ia c)¢ this oer'mit,,
2;. I will adhere to ali MOA arid State o¢ Alaska requirements for' the se~ bacl-:'
distarlces trom any exis+ing well~ wastewater disposal system or' public
APPLICANT: CURT'~S AND S~GRID BLAKE
iSSUED
STATE OF ALASKA
DEP~ME:NT OF NATURAL RESOLJt~.S
DivisiOn of 6~ologigol & Geophysicol $ur~
LOCATION OF WELL (Please eemplata ellPet I,, lb er I¢.) A.G.L, No.
,,.. & ,.. ,.~,.o.p,~ ..,,~, /~ ,~,./,,.
IO..TATIC WATER LEV[L: ~ ft. ~
~Abovl or O ~low Iond
GN~O~MENTA~ VKUI ~'q I~.GROUTING Well Groute~: ~ Yes ~ No
15. Wotlr Ttmplralurl o ~ F ~ C
Municipality of Anchorage
On-Site Water & Wastewater Program
(907) 343-7904
CERTIFICATE OF ON-SITE SYSTEMS APPROVAL
Parcel I.D. 020-! ! ,! ~1~.
1. GENERAL INFORMATION
Expiration Date: .~/3//,~
Complete legal description
Location (site address)
Current Property owner(s)
Mailing address
Real Estate Agent
TYPE OF DWELLING:
RABBIT CREEK VIEW & HEIGHTS; BLOCK 09H~ LOT 15A
16861 NICKLEEN DRIVE *ANCHORAGE, AK
JENNIFER BLAKE
SAM E
DAR WALDEN W/KELLER WILLIAMS
· Single Family (w/wo ADU)
[] Duplex
[] Multiple Dwellings (Single Family and/or Duplex)
3. NUMBER OF BEDROOMS: 4
4. TYPE OF WATER SUPPLY:
Day phone
830-6204
Individual Well ·
Individual Water Storage []
Community Class Well []
Public Water System []
Day phone
865-6500
TYPE OF WASTEWATER DISPOSAL:
Individual On-site
Individual Holding tank
Community On-site
Public Sewer
Received by: / -~'~"~'~' ,*
COSA to be released to the e~gineer, unless othen~ise requested by Ihe engineer.
Date:
COSA Fee $
Date of Payment
Receipt Number
COSA #
qqo,
O$oF2 1 5"'
Waiver Fee $
Date of Payment
Receipt Number
Waiver #
5. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal a~ked hereto and as of the validation date shown below, I verify that my
investigation, based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines for this application,
shows that the on-site water supply gnd/or wastewater disposal system is (are) safe, functional and adequate
for the number of bedreoms and type of structure indicated herein. I further verify that based on the
information obtained from the Municipality of Anchorage files and from my investigation and inspection, the
on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal
and State codes, ordinances, and regulations in effect at the time of installation.
Name of Firm GARNESS ENGINEERING GROUP, Ltd.
Address 5701 E. TUDOR ROAD, SUITE 101 * ANCHORAGE, AK 99507
Engineer's Printed Name JEFFREY A. GARNESS, P.E.
Phone 337-6179
Date
Engineer's Comments:
In conducting this evaluation, GEG, LtD. attempted to provide a thorough,
conscientious engieeering analysis of the system in accordance with ADEC and MOA
DSD Guidelines & Regulations. The reported results described the performance of the
system under the conditions encountered at the time of the test, and separation
distances measured to readily identifiable features. The operational life of ell wells and
septic systems depend on the local soils condition, groundwater levels that may
fluctuate during the year, and the water usage of the family being served by the system.
These conditions are outside the control of the evaluator of the system. Satisfactory test
results do not guarantee future performance of the system, nor do they guarantee that
there are no hidden defects or encroachments. GEG, LTD. can therefore not provide
any warranty or future estimate of how long the system will continue to meet the
operational requirements of the ADEC or MOA DSD. The content of this report is for
the sole benefit of the owner listed above. Any reliance upon or use of this report by any
other person or party is not authorized, nor will it confer any legal right whatsoever.
DSD SIGNATURE
~ System #1 Approved for H bedrooms.
System #2 Approved for
Disapproved.
Conditional approval for __
bedrooms.
WASTEWA ER
bedrooms, with the following stipulat,
The Municipality or Anchorage Develop, emt Services Division (DSD) issues Certificates of On-Site Systems Approval (COSA) based only
upon the represenatations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska.
The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work.
7. ATTCHMENTS:
COSA Checklist
Septic System Advisor~
Wel~w Adviso~
Nitrate Advisory
Arsenic Advisory
Other
Original Certificate Date: /
If more than 1 septic system is on the lot:
COSA Checklist # of
Structure served by this syste-~' -
Certificate of On-Site Systems Approval Checklist
Legal Description: RABBIT CREEK VIEW &: HTS; BLOCK 9H, LOT 15A i,
A. WELL DATA t~l~:~
Well type _PRIVATE
Date completed 7___7/_~_.~7
Total depth 115 ft.
Date of test
Static water level
Well production
Parcel ID:__029 11~4 45:_
IfA, B, or C provide PWSID# .N/A
Sanitary seal (Y/N) _YES
Cased to ~ 15 ft.
FROM WELL LOG
__ 7/15/87
_ ARTESIAN ft. _ARTESIAN
2O
g.p.m. **2,07
Well Log (Y/N) YES
Wires properly protected (Y/N) YES
Casing height (above ground) 12+ in.
AT INSPECTION
___.__~3/12
g.p.m.
WATER SAMPLE RESULTS:
Coliform _C) colonies/100 mi. NitrateQ(° :~ ~rlg./L.
Arsenic: ~/~ ug./L
B. SEPTICIHOLDING TANK DATA
Tank Type/Material STEP/STEEL
Tank size 1500 gal. Number of Compartments _2
Foundation cleanout (Y/N) _YES
Date of pumping_ 5/251~_~_
C. ABSORPTION FIELD DATA ~
Date installed _ 9/20 9~0 Soil rating (g.p.d./ff~or~l 75
Length 27 ff. Width 15 ft.
**BELIEVED TO BE LIMITED BY WATER PRESSURE FROM HOUSE
Collected by: ~GEG. Ltd~_._~
Date of sample: .~/'24/12
Date installed _ 9/_30/88
Cleanouts (Y/N) YES
High water alarm (Y/N)__ YES
Total depth. *_3.5~_ft. Eft. absorption area_~405 ft~ Monitoring tube_~_YES
Date of adequacy test __ 5/3/12 Results (Pass/Fail) .~PASS --
Fluid depth in absorption field before test _ 0 in. Water added 8~880 gal.
Elapsed Time: 1_201 min. Final fluid depth __0 in. Absorption rate >=
Any rejuvenation treatment (past 12 mo.) (Y/N & type) NONE
If yes, give date ~
*NO WATER WAS OBSERVED IN CLEANOUTS DURING TEST. PEAT MOUND WAS N,.~OT INSPECTED
Depression over tank (Y/N) _NO
Pumper_ A+ HOME SERVICES
System type __ BED/MOUN~D
Gravel below pipe _ 0.5 ft.
Depression over field N~O
For_ 4- bedrooms
New depth. *5_in.
600+ g.p.d.
D. LIFT STATION *ASSUMED
Date installed 8/30/88 Size in gallons 1500
"Pump on" level at 68 in. "Pump off' level at 68 in.
Datum TOP OF MH Cycles tested 5+
E. SEPARATION DISTANCES
SEPARATION DISTANCES FROM WELL ON LOT TO:
Septic tank/lift station on lot 100'+
Absorption field on lot 100'+
Public sewer main N/A
Sewer/septic service line 25'+
Animal containment areas 50'+
Manhole/Access (Y/N) YES
High water alarm level at 64.5 in.
Meets alarm & circuit requirements?. *YES
On adjacent lots *.100'+
On adjacent lots *,100'+
Public sewer manhole/cleanout N/A
Holding tank N/A
Manure/animal excrete storage areas 100'+
SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO:
Building foundation 5'+ Property line 5'+
Water main N/A Water service line. 10'+
Wells on adjacent lots ** 100'+
SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO:
Property line *,3'
Water service line 10'+
Curtain drain ***22'
F. COMMENTS
Building foundation 10'+
Surface water ~*** 1
Wells on adjacent lots ** 100'+
Absorption field 5'+
Surface water ***50'
Water main N/A
Driveway, parking/vehicle storage
*PER 1988 INSPECTION REPORT. TOE OF MOUND IS OFF PROPERTY. **SEE AT[ACHED LET[ER
DATED 5/17/2012...***SEE ATTACHED WAIVER REQUEST,
f***SEE ATTACHED SKETCH
G, ENGINEER'S CERTIFICATION
I certify that I have determined through field inspections and
review of Municipal records that the above systems are in
conformance with MOA COSA guidelines in effect on this
date.
10'+
JEFFREY A. GARNESS
Engineer's Printeft Name
Date C~ /l~/~Z
COSA Fee $
Date of Payment,
Receipt Number
(Rev. 11~)5)
Waiver Fee $
Date of Payment_
Receipt Number,
Municipality of Anchorage
P.O. Box 196650 · 4700 Elmore Road
AnchoraRe A aska 99519-6650 · (907) 343-7904 · Fax ('907) 343-7997
http:l/www.muni.or.qlOns te
Development Services Division
On-Site Water and Wastewater Proqram
VARIANCE/WAIVER REVIEW ****
Waiver#: OSP121303 CASA#: OSC121425 Permit:
PID#: 020-581-29
Legal Description: Rabbit Creek View & Heiahts, Block 9H, Lots 'I3A and 'I4A
Engineer: Garness En.qineerin.q Group
Applicant: Jennifer Blake
Your request for a waiver of the required 100 feet horizontal separation from the septic tank to
the surface water has been approved. The approved separation distance is 50 feet.
Your request for a waiver of the required 50 feet horizontal separation from the absorption field
to the curtain drain has been approved. The approved separation distance is 22.0 feet.
Your request for a waiver of the required 50 feet horizontal separation from the peat mound to
the curtain drain has been approved. The approved separation distance is 27.0 feet.
This waiver approval applies to the existing septic system only. Any future upgrade to the on-
site wastewater disposal system will require all separation distances be met or another approval
from this department.
[] The affected adjacent property owner(s) have been given a 7 day notice regarding this
waiver.
[] Notarized letter(s) of non-objection have been received from the owner(s) of the affected
adjacent property.
[] Adjacent properties are not affected by this waiver.
Waiver is Granted: X Waiver is not Granted:
Date: l'/~//~ Approved /,j Name of Reviewer
Rec#: 06393G Amount: $800.00 Date Paid: 9/14/2012
**** VARIANCE/WAIVER REVIEW ****
GARNESS ENGINEERING GROUE Ltd.
CONSULTANTS & GENERAL CONTRACTORS
May17,2012
Municipality of Anchorage
Development Service Department
On-Site Water & Wastewater Program
4700 Elmore Rd.
P.O. Box 196650,
Anchorage, Ak 99519-6650
(907) 343-7904
Ref: COSA approval for Rabbit Creek View and Heights Block 9H, Lot 14A
To whom it may concern:
Gamess Engineering Group Ltd, (GEG) recently completed a septic and well test on the referenced
property. As part of the inspection, GEG attempted to pull records on numerous surrounding properties
with no success. GEG spent time walking each of the surrom~ding properties and was only able locate a
well and septic system on one of the surrounding properties.
Records for the well and septic systems could not be found, nor the well and septic systems physically
located in the field on the following neighboring properties:
· Rabbit Creek View and Heights Block 9H Lot 12A
· Rabbit Creek View and Heights Block 9H Lot 5A
· Rabbit Creek View and Heights Block 11H Lot 1A
Based upon the fact that neighboring wells and septic systems could not be physically found, it is
assumed that the req~fired separation distances exist.
( i/Y t
\~?s, m ~C~'i.S.
3701 E. Tudor Road, Suite 101 * Anchorage, AK 99507-1259
Ph: (907) 337-6179 * Fax: (907) 338-3246 * Website: www.gamessengineering.com
GARNESS ENGINEERING GROUP, Ltd.
CONSULTANTS & G~::NERAL CONTRACTORS~
August 15, 2012
Municipality of Anchorage
Development Service Department
On-Site Water & Wastewater Program
4700 Elmore Rd.
P.O. Box 196650,
Anchorage, Ak 99519-6650
(907) 343-7904
Reft Waiver Request for Rabbit Creek View and Hts. Block 9H, Lots 13A and 14A
To whom it may concern:
The existing 4 bedroom house is served by a private well and septic system. The septic system includes a
1500 gallon lift station, a peat treatment mound, and a bed type drainfield. During a site visit completed
by GEG, it was discovered that a curtain drain existed between the back of the house, and both the
drainfield and the peat mound encroach on the curtain drain. The location of this drain was professionally
located by a sewer and drain company. The distance between the drain and the peat mound is
approximately 27', and the distance between the drain and the drainfield is approximately 22'. The
distance between the ouffall of the curtain drain and the septic tank is 50'.
The property is currently for sale and will be occupied as of 8/22/12. We are proposing to test the water
rtmning out of the curtain drain outfall for coliform bacteria every month for three months. Should the
drain outfall test positive for coliform bacteria in 90 days, we propose to design and install a new 1500
gallon lift station and a Quanics Aerocell 650 pod on top of the existing drainfield.
We request at this time a conditional COSA approval based upon our sampling plan with the separation
distances previously stated. We are unaware at this time of any adverse impacts that granting this waiver
adjacent wells or septic systems. If you have any questions, please contact us at 337-6179.
Thank,
' Attached is a siteplan drawing.
3701 E. Tudor Road, Suite 101 * Anchorage, AK 99507-1259
Ph: (907) 337-6179 * Fax: (907) 338-3246 * Website: www.gamessengineering.com
GAR'NESS ENGINEERING GROUE Ltd.
CONSULTANTS & GENERAL CONTRACTORS
November 30, 2012
Municipality of Anchorage
Development Service Department
On-Site Water & Wastewater Progrmn
4700 Elmore Rd.
P.O. Box 196650,
Anchorage, Ak 99519-6650
(907) 343-7904
Ref: COSA approval & Waiver Requests for Rabbit Creek View and Heights Block 9H,
Lot 14A ~ ~ gA
To whom it may concern:
Gamess Engineering Group Ltd, (GEG) completed a septic and well test on the referenced
property in the spring of 2012 while there was still several feet of snow on the ground. Later,
during a high water alarm repair, A+ Home Services discovered a sewage discharge on the
property (revealed under the melting snow pack), approximately 20' North of the septic tank.
After this observation, exploratory digging took place to find the source of the sewage. A broken
sewer line was discovered just outside of the STEP tank. This broken pressurized line was
discharging effluent into what is believed to be an old abandoned foundation drain which was
routed into or near an old abandoned septic tank. The pressurized line was repaired, and the old
foundation drain outfall was abandoned in place. During the repair, a curtain drain was also
discovered. This curtain drain outfall was found 55' away from the septic tank.
Per an agreement with your department, GEG proceeded to take samples (approximately every
30 days) to test for Fecal Coliform at the curtain drain outfall for a period of three months. It
should be noted that GEG inadvertently stated that we were testing for Colifrom bacteria in our
conditional request letter of 8/15/12, when we were intending to test specifically for Fecal
Coliform. Our first sample tested negative for Fecal Coliform. The second sample was taken
during an isolated rain event that lasted for several weeks, while your department was onsite.
During this sampling, the outfall of the curtain drain was underwater and the drainage swale
along the Northeast property line was full of water. An accurate isolated sample from the ontfall
of the curtain drain could not be obtained. The sample was tested positive for Fecal Coliform (19
col/100mL). It is likely that the source of this Fecal Coliform came from upslope of our client's
property. The 3rd and final sample was taken recently near the 90 day mark (after the rain
subsided), and tested negative for Fecal Coliform. We believe that the sampling confirms the fact
that untreated effluent is not migrating laterally into the curtain drain from either the peat mound,
or the drainfield.
3701 E. Tudor Road, Suite 101 * Anchorage, AK 99507-1259
Ph: (907) 337-6179 * Fax: (907) 338-3246 * Website: www. gamessengineering.com
Your office had addressed a settled out section of ground near the STEP tank that was holding
surface water during the rain event, and a depression around the well casing. Both of these items
have been filled to prevent ponding water.
During the filling around the well casing, the contractor observed water overflowing from the top
of the sanitary seal. It is our understanding the Aarow Pump and Well Service had previously
replaced the plug in the top of the well casing to stop the water from daylighting from the top of
the well. Since then, Arrow Pump m~d Well Service returned to make some adjustments to the
well plug. Upon our inspection several weeks later, it appears that Arrow was successful in
plugging the top of the well.
At this time, we request that a non-conditional COSA be issued for this property.
~.e's~.Reg~rd~Q~t
Jeff G~ess'xP.EJ, M.S.
ere?!~te~
3701 E. Tudor Road, Suite 101 * Anchorage, AK 99507-1259
Ph: (907) 337-6179 * Fax: (907) 338-3246 * Website: www.gamessengineering.com
LOT I~A
LOT 13A
RADIUS
SCALE:
GARNESS ENGINEERING GROUP, Ltd.
JENNIFER BLAKE 8.30-6204 I 1 OF 1
RABBIT CREEK HEIGHTS; BLOCK 9H, LOT 13A & 14A PNB
TYPE OF WORK: DATE:
WAIVER REQUESTS 8/:3/12