On-Site Wastewater Disposal System and/or Well Inspection Report
Permit Number: SW020378 PID Number: 020-- 113--50
JIM CUCCULU Wastewater System: · New i'-I Upgrade
Address:
8101 E. 140th AVENUE * ANCHORAGE, AK 99516 ABSORPTION FIELD
Phone: No. of Bedrooms:
(907) 345-5544 5 r-IDeep Trench · Shollow Trench [] Bed []Mound []Other
LEGAL DESCRIPTION ,o,, Rating: T~ta, Depth from original grade:
1.2 ORb/Sq. Ft. 6.5 MAX
10 25 RABBIT CREEK HEIGHTS 2.4 (MAX) F~ 4.1
SEE DWO. F~ 63 Ft
WELL: · New [] Upgrade 5 ~ 1 - ~t,
PRIVATE 167 Ft. 104 Ft. 630 S~. Ft D 3034/ F'-8~O/ SCH 4O
ALPINE DRILLING 7/6/2005 10 Ft. DAN BEEK 6/21/2003
8 GP~ UNKNOWN 2 ,. TANK
SEPARATION DISTANCES ~ s~pt~= []Holding m S.T.E.P. [3 Other
T~o Septic Absorption Uft Holding )ubllc,/PH¥~l Menufacture~ C~3p~acfty in gellons:
Tonk Field Station Tank S..o.U... ANCHORAGE TANK 2000
Well 100'+ 100'+ - - 25% ~..o1: STEEL ..mb,, ~ ~o,,,.~o,~: 2
Sun~ac, Water 100'+ 100'+ - - - LIFT STATION
Lot Line 5'+ 10'+ -- mz~ I, ,o~m..: ANCHORAGE
- - 2000 TANK/ORENCO SYSTEMS
Cur[ain Drain NONEi KNOWNi J~20 OSI 05 HHF OWEN'S INSPECTION
~e~nork~: BENCH MARK
TOP OF GARAGE SLAB
100.00
or
~nspections performed by: AKWWC, INC. Dates: ist 6/21/2003
2nd 6/21/2003
era 6/21/2003 )* .~j~ ,/i '~.''~o~,e,,: ~
Development S rvices Department Approval ~0~"~."' I/C -795~"
R~viewed and approved by: Ci'~ Date: ///J/aY'
(,o,. L ,~, res'
PERMIT NUMBER: AS BUILT DRAWING PARCEL ID NUMBER:
SW020578 - 020-113-50
/ NyTWE.~?OC~2LLO N
~ ~ ~ ~ ~HL ~ ~ALTERNATE
DRAINFIELD
12/15/2003 ~¢ Ur.l~, ~.
~~ ~I ER & ~VAS l EW~I ER
~ ~ CONSU LTAN~S~ J NC~
PREPARED FOR: PHONE NUMBER: PAGE NUMBER; .............
~ DESCRI~ION: .. [-7953 .."
AS-BUILT DRAWING OF SEPTIC SYSTEM
PE. ,t .U BE : AS--BUILT DRAWING
SW020578 020-
f FINAL GRADE = 101.74)AVG)
TOP OF TANK ~1 / ~2 ~:~ / TOP OF TANK
AT ,NL~ = 96.78~ .- ----- ~ ~TL~ = 96.80
/r NEW 2000 GALLON /~
~T C , ~ FI~ GRADE = 111,00(AV~)
HOLES SPACED ~ERY 24" ON CENIEE
[ 5' I~BOWOM OF IRENCH = 104.02(AV6)
-~ RESTIVE EL~AIION OF
TESt HOLE =96.02(TH DRY)
........ CONSULTANTS, INC,~ SCALE: 4
JIM CUCULLU (907) 545-3544 5 OF 5 "
RABBII CREEK HEIGHTS SUBDIVISION; LOI 25, BLOCK 10
PROFILE AS-BUILT DRAWING Of SEPTIC SYSTEM UPGRADE
FROM : ALPINE DRILLING FAX NO. : 907 345 0202 Jul. 31 2003 ll:4TAM Pi
Municipality of Anchor. age
Department of HeaR. h. and Human Serv,ces
825 L Street
P.O. Box 196650 Anchorage, Alaska 99519-6650
Rick My$ffom ht~p:l/www, ci,anchorage,ak, us
Meyor
Permit Number: #SW 02037'8 Date of Issue: 9/30/02 Parcel Identification Number: 020-/, 13.50
Date Started: 7-05-03 Date Completed: 7-06-03 Is well located at approved permit location? [] Ye~ [] No
Legal Description:
Propert~ O,.uer Nsme & Address:
Rabbitt Cmk. k Hoht~. BIk. 10. Lot 25
Jim Cucullu
8~01 East 140~ Ave.
Anchora, ~e, Alaska 9951,6
Depth (ft)
From To
Method of Drilling ~ air rotary
Borehole Data: -"
Soil Type, Thic, lm=~ & Water Strata
stick-up 0 2
gravelly sit 2 57
$ifly gravelly sand wet 57 60
gravelly silt 60 lO0
bedrock 100 167
[] cable tool
Casing type: .,s~eel
Diameter: ~inches Depth: ,I0,4 f~t
Liner Type:, ,
Diameter: ~ inches Depth: feet
Casing stickap above ground: ~ feet
Static water level (from ground level): 10feet
Pumping level: 167 feet after
_2 hours pumping _8 gpm
Reeovery Rate: _8 gpm
Method of Testing: airlift
Well Intake Opening Ty~e:
[] Open End [] Open Hole
[] Screened Shirt feet Stopped , feet
[] Perforations Start feet Stopped feet
Grout Type: bentonite # 8 Voinme: ~ bg
Depth: Start 0feet Stopped ? feet
Pump: Intake Depth , feet
Pump size ILo Brand Name
Well Disinfected Upon Completion? [] Yes [] No
Method of Disinfection:
Comments:
Well Driller.
Alpine Drilling & Enterprises
PO Box 110496
Anchorage Alaska 995t I
Attention: The well driller shnll proi, idea well log to ~he property owner within 30 days of complellon and the property
MUN/C/PALITY OF ANCHORAGE
Development Services Department
On-Site Water & Wastewater Progrem
4700 South Bragaw Street
P.O. Box 196650, Anchorage, AK 99519-6650
(907) 343-7904
ON-SITE WASTEWATER DISPOSAL SYSTEM /WATER SUPPLY PERMIT
Initial
Date Issued: Sep 30, 2002
Expiration Date: Sep 30, 2003
Permit Number: SW020378
:Legal Description: RABBIT CREEK HEIGHTS BLK 10 LT 25
Design Engineer: 0041 AK Water & Wastewater Consultan'
Owner Name: Jim Cucullu
Owner Address: 8101 East 140th Ave
Anchorage, AK 99516-
Pamel ID: 020-113-50
Site Address: 008220 ROBERT DR
Lot Size: 21306 SQ. FT.
Total Bedrooms: 4 Permit Bedrooms: 4
This permit is for the construction of:
[] Disposal Field [] Septic Tank [] Holding Tank [] Privy
[] Private Well
[] Water Storage
All construction must be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations ( '/8AAC72 ) and Drinking Water Regulations ( 18AAC80 ).
3. The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling
(907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ).
4. From October 15 to April '15, a subsurface soil absorption system under construction during freezing weather
must be either: A. Open and closed on the same day.
B. Covered, sealed, and heated to prevent freezing.
Received By: ~
IssuedBy:~~- ~
!
Date:
Date:
Municipality of Anchorage
Development Services Department
Building Safety Division
On-Site Water & Wastewater Program
4700 South Bragaw St.
P.O. Box 196650 Anchorage. AK 99519-6650
www.ci.anchorage.ak.us
(907) 343-7904
Parcel I.D.
ON-SITE SEWER/WELL PERMIT APPLICATION
FOR A SINGLE FAMILY DWELLING
[~:~ it ~~ ~'P Permit Number
Property owner(s)
Mailing address (1)
Mailing address (2)
JIM CUCULLU
8101 EAST 140TH AVENUE * ANCORA(;E. AK
Day phone 345-3544
Zip Code 99516
Legal description (Lot, Block & Sub'd.)
Legal description (Section, Township & Range)
Lot Size ~?-,~,/,~-,~ [~2
THIS APPLICATION IS FOR:
Sewer Only
Sewer and Well
Sewer Upgrade
THIS PROPERTY CONTAINS:
Hot Tub
Swimming Pool
Therapy Pool
Acre~
LOT 25. BLOCK 10: RABBIT CREEK HEIGHTS SUBI~IVI$10N
N./A
Number of Bedrooms 4
[] Well Only []
· Water Storage []
[] Jacuzzi ' []
[] Water Softening Unit []
I certify that the above information is correct. I further certify that this application is being made for a
Single Family Dwelling and is in accordance with applicable Municipal codes.
ALASKA WATER &: WASTEWATER CONSULTANTS~ INC.
Permit Fees: ~/"/~)0° 'J' '~"~"~'"~'~5~ '"~ai~vver Fees.'.
Date of Payment: Date of Payment:
Receipt Number:~ Receipt Number:
ALASKA WATER & WASTEWATER
CONSULTANTS, INC.
March 12, 2003
Municipahty of Anchorage
Development Service Department
Building Safety Division
On-Site Water & Wastewater Program
4700 South Bragaw Street
P.O. Box 196650
Anchorage, AK 99519-6650
Reft Revisions to the Proposed Septic System Design (Permit# SW020378)
for Lots 25, Block 10; Rabbit Creek Heights Subdivision
To whom it may concern:
A permit (#SW020378) was issued for a proposed well and septic system for the referenced
property. An Advantex Treatment System was to be installed on the property. A confirmation
test, labeled test hole #3, was excavated south of test hole #2 and a percolation test was
performed between 5.0 to 5.5 feet which found the rate to be <1 minute/inch. It is our opinion
that the insitu sandy soils will act as a sand filter. No groundwater was encountered to the depth
of 14.5 feet in test hole #3 during the excavation. The highest groundwater level in test hole #2
was found to be between 11 to 11.9 feet during the month of September. Based upon this
information, we m'e proposing to revise the design to use a 2000 gallon S.T.E.P. tank and a
pressurized 5-wide drainfield. Also, per the homeowners request, we are designing for a 5
bedroom house instead of a 4 bedroom house. We request that a revised permit be issued to
include these changes. The following is the revisions to the design criteria:
REVISIONS TO TRENCH DESIGN:
a. Percolation Rate: 1 & <1 miuntes/inch
b. Proposed Application Rate: 1.2 gallons/day/ft2
c. Number of Bedrooms: 5
d. Design Flow: 750 gallons per day
e. Minimum Absorption Area: 625 ft2
f. Total Depth: 6.5 feet (max.)
g. Effective Depth: 4 feet
h. Width: 5 feet
i. Reduction Factor: 0.50
j. Minimum Length: 63 feet long
k. Effective absorption area: 630 ft2
6901 Debarr Road, Suite 2B ~ Anchorage, AK 99504 ~ Ph: (907)337-6179 ~ Fax: (907)338-3246
Note: the distribution lines are to be 1.25 inch Schedule 40 PVC with ¼ inch diameter holes
spaced 24 inches on center (15 holes per lateral/30 holes total).
TOPOGRAPHY: The average topo~'aphy in the area of the proposed drainfield is a 10%-15%
slope running approximately south/southwest to north/northeast. In short, there are no slope
concerns.
CLOSING: I am open to any suggestions bom your department that would be an improvement
to the proposed system. I am unaware of any negative impacts that this installation would
impose on adjacent wells, or septic systems. If you have any questions, please call us at 337-
6179. ~a~
s.
Pres/ ~
6901 Debarr Road, Suite 2B ~ Anchorage, AK 99504 ~ Ph: (907)337-6179 - Fax: (907)338-3246
% '~' ~OOD ~'RCLE _
DA~:
JIM CUCULLU 345-~544 1 OF 4
RABBIT CREEK HEIGHTS SUBDIVISION LOT 25, BLOCK 10 ~t~ [.~ ........ .~
~ o~ wo.~: ,~ _
SITE P~N FOR PROPOSED WELL AND SEPTIC SYSTEM
NOTE: THE CONTRACTOR SHALL HAVE THE
PROPOSED 100' WELL RADIUS AND THE EAST AND
SOUTH LOT LINES FLAGGED BY A REGISTERED
. LAND SURVEYOR PRIOR TO CONSTRUCTION
,t..~9-' ~ ~ }~{i:.ii'" '~!!!X ~ ~EVISED
~./ DF'SIGN i
xx-"~-'..2;-~?,..~...-: :".':/;...:\ \ rPRoPosE, 20°°
~ ~ / ~ / (15 HOLES PER ~TREm~30 HOL~ TOT~).
~T~: REVISED
M~~ ~VATER & WASTE~VATERc.~.~./~.L.~.
'[~... ~ ~:~ ~ '..~
- CONSULTANTS, INO. - 1"
JIM CUCULLU (907) 545-5544 2 OF 4 ~ '. leffl ~!' A. Gorness.-'
-
RABBIT CREEK HEIGHTS SUBDIVISION; LOT 25, BLOCK 10, ~'-~.~ ......... .-'
DESIGN DRAWING OF PROPOSED WELL AND SEPTIC SYSTEM
ALASKA WATER & WASTEWATER
· ¢.r3CON~S,U. LTANT$, Ir,l,(,... 7
ISOIL LOG - PERCOLATION TESTI
LEGAL DESCRIPTION: .~BIT CRE£K HEIGHTS; LOT 25, BLOCK 10 __ __
JIM CUCULLU DATE: 9/11/2002
PERFORMED FOR:
ORGANICS
ITEST HOLE
SOIL CLASSIFICATIONS
ORG
HL
CL
OL
HH
CH
OH
SC
DEPTH TO DATE
GROUNDWATER
10' 9/11/2002
6.8' 9/13/2002
S.8' 9/18/20
SOILS LOGGED BY:
COHP1ENTS:
DATE READING CLOCK NET TIHE WATER LEVEL NET DROP
TIHE (HINUTES) READING (INCHES)
9/13/2002 1 - _ 6- -
2 - 5 O" 6"
5 - _ 6. -
4, - 6 O" 6"
6 - 6 O" 6"
8 - 6 O" 6"
10 - 6 O" 6"
11 - _ 6. -
12 - 6 O" 6"
PERCOLATION RATE (MIN./INCH) PERC. HOLE DIA. 6 (INCHES)
TEST RUN BETWEEN 5.0 FT. AND 5.5 FT.
A FOUR HOUR PRESOAK WAS PERFORMED: r-"lYES I NO
SUSAN OSWALT PERCOLATION TEST PERFORMED BY: MA'FI'FISCHER
PERFORMED BY AKWWC, INC. I, JEFFREY A. GARNESS, CERTIFY THAT THIS WA,8 PI~RFORMED IN ACCORDANCE I
WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE:
I
ALASKA WATER & WASTEWATER
-- h... ...... ~ ......... :.,..~
A. ~ss.'
PERFORMED FOR: JiM CUCULLU DATE: 9/11/2002 [-7953 .."
DEPTH ~
(feet) ORGANICS [TEST HOLE
GH CL
GC 0L
~ SP CH
SC
DEPTH T0 DATE
GROUNDWATER ~
SM 11.0' (SEEP) 9/11/2002
11.9' 9/18/2002 ~,~' JSITE P~N
2 - 2 O" 6"
13 ~ 3 - _ 6- -
~ - 2 O" 6"
1~ 5 - _ 6- -
6 ~ 3 O" 6"
15 ~ 7 - _ 6- -
16 8 - 3 O" 6"
9 - _ 6- -
17 10 - 3 0"' 6"
11 ~ - _ 6- -
18 12 - 5 O" 6"
PERCOLATION RATE <1 (HIN./INCH) PERC. HOLE DIA. 6 (INCHES)
19
TEST RUN BETWEEN 5.0 FT. AND 5.5 FT.
20 A FOUR HOUR PRESOAK WAS PERFORHED: ~ YES ~ NO
SOILS LOGGED BY: SU~N OSWALT PERCOLATION TEST PERFORMED BY: MA~ FISCHER
COHHENTS:
PERFORMED BY AKWWC, INC. I, dEFFR~ A. GARNESS, CERTI~ THAT THIS W~S P~RFORMED IN ACCORDANCE
WITH ALL ~ATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE:
DEPTH TO DATE
GROUNDWATER
11,0' (SEEP) 9/11/2002;
~11.9' 9/13/2002
11.9' 9/18/2002
CONSULTANTS,]NC.~ ,~...."
~ ...... ...... .~ ~ ........
ISOIL LOG - PERCOLATION TEST~
LEGAL DESCRIPTION: RABB~ CREEK HEIGHTS S/D; LOT 25, BLOCK 10,
PERFORMED FOR: JIM CUCULLU DATE: ~/10/200~
(feet)'~ .... ORGANICS ITEST HOLE ~3I
5- sw
SP CH
s_ :~Z, , sc
7-- ~]~::::' DEPTH TO
S ~ O~OUNDWATER DATE
8-- ,,~,,., MIXED DRY ~/10/0~
,.,.... -
9-- i~)~ WITH DRY 3/11/03
GRAVEL
:~:~ DATE READING CLOCK NET TINE WATER LEVEL NET DROP
11 -- ~¢:~ TINE (MINUTES) READING (INCHES)
12__~¢:~¢~ ~/11/0~ __ 1 __ 2:~6 - 6- _
1]-- ~[~ 3 2:39 - 6- _
4 2:41 2 O" 6"
~ 5 2:42 _ - -
B.O.~, 6 2:45 5 O" 6"
15 -- 7 2:52 - 6. -
16 -- 8 2:55 5 0" 6"
9 2:55 - 6. -
17 -- 10 2:58 3 0"' 6"
11 2:59 - 6- -
18-- 12 3:02 3 0" 6"
PERCOLATION RATE <1 (MIN./INCH) PERC. HOLE DIA. 6 (INCHES)
19-
TEST RUN BETWEEN 5.0 FT. AND 5.5 FT.
20 ~ ~ A FOUR HOUR PRESOAK WAS PERFORMED: ~ YES I NO
SOILS LOGGED BY: MA~ FISHER PERCOLATION TEST PERFORMED BY: MA~ FISHER
COMMENTS: THE INSI~ ~NBY SOILS WILL ACT AS A SAND RLTER.
PERFORMED BY AKWWC, INC. I, JEFFR~ A. GARNESS, CERTI~ THAT THIS W~ P~RFORMED IN ACCORDANCE
WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE: ~/I
DEPTH TO
GROUNDWATER DATE
DRY 3/10/0~
DRY 5/11/03
GE BL
• "� Municipality of Anchorage n
.o
On -Site Water and Wastewater Program._ {'
(907) 343-7904 5 a F E T Y
Certificate of On -Site Systems Approval
Parcel I.D. 020-581-51
1. GENERAL INFORMATION:
Expiration Date: S / �, -Zd ZZ
Complete legal description RABBIT CREEK VIEW AND HEIGHTS; BLOCK 10H LOT 25A
Location (site address) 8220 Robert Drive *Anchorage
Current Property owner(s) Leroy Jester Day phone 903-1213
Mailing address
Real. Estate Agent
2. TYPE OF DWELLING:
® Single Family (w/wo ADU)
❑ Duplex
❑ Multiple Dwellings (Single Family and/or Duplex)
_Day phone
3. NUMBER OF BEDROOMS:
5-
4. TYPE OF WATER SUPPLY:
TYPE OF WASTEWATER DISPOSAL:
Individual Well
®
Individual
Individual Water Storage
❑
Holding Tank
❑
Community Class Well
❑
Community
❑
Public Water System
❑
Public Sewer
❑
WaiverNariance request for.
Received by:
COSA to be released to the engineer, unless otherwise requested by the engineer.
COSA Fee $__-650
Date of Payment Z -/�� 2Z
Receipt Number _C VT L -1d
COSA # 05 G Z2_1 0 ��
Date:
Waiver Fee $ _
Date of Payment
Receipt Number,
Waiver #
5. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation,
based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application,
shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate
for the number of bedrooms and type of structure indicated herein. I further verify that based on the information
obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water
supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes,
ordinances, and regulations in effect at the time of installation.
-_ _� __—_ ==Name of-Firm:-Gamess=Engineering-Group,=Ltd=(GEG)— - - - _Phone:=-907-337-61.79---__�_
-
Address: 3701 East Tudor Road, Suite 101- Anchorage, Alaska 99507
Engineer's Printed Name: Jeffrey A. Garness
Date:
In conducting this evaluation, GEG provided an engineering evaluation of the well and/or septic system
in accordance with the guidelines and regulations established by the Municipality of Anchorage and
��aooU�40
Industry practices. The reported results describe the condition of the systems on the date/s of the
evaluation. Separation distances were measured to readily identifiable features. Hidden defects or
C
-
--------
.•••"'encroachments
encroachmentsmay exist that were not identified during the evaluation. The operational life of all wells
Ol�
and septic systems depend upon a variety of variables, including but not limited to, soil conditions,y
1
groundwater levels (that may fluctuate during the year), quality of construction (materials and
the the family the These
Q
�" """" '. "' """"
workmanship), and water usage of utilizing system/s. conditions can vary, and
are outside the control of GEG. Satisfactory test results do not guarantee future performance of the
– - system/s; therefore, GEG makes no warranty (express or. implied) regarding the future performance of
the well or septic system. GEG makes no representation whether an alternative well or septic system
i/�^.. .. • • • . • • • • • • . •.. • • • •• • •
J= f fr `. Gcrn ss.-* G'
can be installed on the in the event either of the systems fail to in
�)l,u ' E–?
property current perform adequately
the future. The content of this report is for the sole benefit of the person/party that retained GEG to
.
ulf ' •.J� °�U
/5'
perforin the evaluation. Reliance upon the information provided in this report by any other person or
���re7 r .
Eo
party (including subsequent property purchasers) is not authorized, nor will it confer any legal right
\
�1 pr^yes=0"
whatsoever.
6. DS IGNATURE
System #1 Approved for bedrooms
System #2 Approved for bedrooms
Disapproved
\Nl]
Conditional approval for bedrooms, with the followit�`f ulations:
f�))' 7tf'dl��N�
By: l/v\ I-�X Original Certificate Date ))ji)?w11
The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only
upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality
of Anchorage is not responsible for errors or omissions in the professional engineer's work.
7. ATTACHMENTS:
COSA Checklist_ Nitrate Advisory
Septic System Advisory Arsenic Advisory
Well Flow Advisory Other __X_�—X o,�,ki A-o1vi S i vv y
COSA Checklist
Legal Description: RABBIT CREEK VIEW AND HEIGHTS; BLOCK 10H, LOT 25A parcel ID: 020-581-51
If more than 1 septic system on lot: COSA Checklist # of
A. WELL DATA
_Wel-I_log-is::filed with Onsite_(or_attached)—_ --_
Date drilled 7/6/03
Total depth 167 ft
Cased to 104 ft
Sanitary seal is functioning correctly
❑■ Wires are properly protected
Casing height (above ground) 18+ in.
Date of flow test for COSA 2/1/22
Static water level at beginning of test 14.8 ft.
Comments
B. TANK DATA
Age of tank(s) 19 years
Tank type/material 8'E5'Ea
Measured operating fluid level in septic tank ST1-31'
❑■ Standpipes/foundation.cleanout per record drawing
Date of pumping 2/9/22
D. ABSORPTION FIELD DATA
Structure served by this system
-—Well.production-at=time-of=test=21'==gpm _ __—
Water storage tank volume N/A gallons
Well di nfected for coliform test? ❑ Yes M Nc
[31,Coliforrn bacteria is Negative
Nitrate N mg/L ❑ Nitrate less than MRL (ND)
Arsenic ug/L LMArsenic less than MRL (ND)
Collected by GEG, LTD.
Date of Sample 211/22
C. LIFT STATION
FN Required maintenance completed
Age of lift station 19 years
Lift station material STEEL
Comments:
Which system tested (date installed) 6121/03
Adequacy test date 2/1/22
0 ALL standpipes present per record drawing
Results QPass For 5 bedrooms
Total measured depth from grade 8.25 ft (max)
Fluid depth prior to test 24 in
Measured depth to pipe invert from grade ft (min)
Water added 876 gal
Q N/A — pressurized field
30
New depth in
❑ Monitor tubes go to bottom of effective. If not, state
120
depth into effective '
Elapsed time min
0 Code -required soil cover over field
Final fluid depth 26 in
❑ System presoaked
Absorption rate 750+ gpd
(Required if vacant for greater than 30 days prior to
Any rejuvenation treatment (past 12 months) NO
date of test)
Gallons introduced NIA gallons
If yes, enter date N/A
Comments/Deficiencies: '4' DIFFERENCE IN ELEVATION BETWEEN MT1 & MT2
COSA Checklist yellow sheet
E. SEPARATION DISTANCES
From Private Well on Lot to: (Please enter distances if less than required or if community well)
0 Yes
if No
Septic Tank/Lift Station on Lot > 100'
Surface Water > 100'
0✓ Yes
Community Sewer Manhole/Cleanout > 100'
ft
Ov Yes
if No
ft
❑✓ Yes
if No
ft
Neighboring Tank > 100' 0✓ Yes
if No
ft
Private Sewer/Septic Line > 25'[D Yes
if No
ft
__ Abso[ption_Field=on Lot:> 1.00',0% :Y_esif_No
- .
,_ it.--
--- Holding Tank ->.1.00'- - __ ,-__Q✓ =Yes-if_No--ft-
Water Main > 10'
0 Yes
Neighboring Absorption Fields > 100'
ft
Community Wells > 200'
Animal Containment > 50' Yes
if No
ft
[D Yes
if No
ft
ft
If septic tank is under driveway comment below
From Absorption Field on Lot to: (Please enter distances if less than required)
Manure/Animal Excreta Storage > 100'
Building Foundation > 10`
Q Yes
Community Sewer Main > 75' 0 Yes
if No
ft
-0✓ Yes
if No
ft
From Septic/Holding Tank on Lot to: (Please enter distances if less than required)
Building Foundations > 10'
0 Yes
if No
*5'+ ft
Surface Water > 100'
0✓ Yes
if No
ft
Property Line > 5'
Q Yes
if No
ft
Wells on Adjacent Lots:
Absorption Field > 5'
Yes
if No
ft
Private Wells > 100'
Yes
if No
ft
Water Main > 10'
0 Yes
if No
ft
Community Wells > 200'
Q Yes
if No
ft
Water Service Line > 10'
121 Yes
if No
ft
If septic tank is under driveway comment below
From Absorption Field on Lot to: (Please enter distances if less than required)
Building Foundation > 10`
Q Yes
if No
ft
If absorption field is under driveway comment below.
Property Line > 10'
Yes
if No
ft
Wells on Adjacent Lots:
Water Main >1 0'
Q Yes
if No
ft
Private Wells > 100'
El Yes
if No
ft
Water Service Line > 10'
El Yes
if No
ft
Community Wells > 200'
0 Yes
if No
ft
Surface Water > 100'
✓0 Yes
if No
ft
F. ENGINEER'S COMMENTS
*MET CODE AT TIME OF INSTALL - ST1 IS APPROXIMATELY 3' TO DECK POST
(SEE ATTACHED PHOTO). BASED ON LIQUID LEVEL IN 1 ST COMPARTMENT
OF S.T.E.P. TANK, THE BAFFLE MAY BE COMPROMISED BETWEEN COMPARTMENTS.
G. ENGINEER'S CERTIFICATION
I certify that I have determined through field inspections and review
of Municipal records that the above systems are in conformance with p* :.
MOA COSA guidelines in effect on this date. ...... _ _
fr y` A. a ss"
9; !• 0�4E-7953 _ �r •• r� �j�¢''r'• .cG
COSA Checklist yellow sheet4�ed °ro F e s sion&
#AECC884 4��DOD�Oo
MUN0C PAP T V ®F A, HCHO A GE
DEVELOPMENT SERVICES DEPARTMENT "�{` 907-343-7904
On -Site Water and Wastewater Section` 4
�,`� .� Fax: 343-7997
www.muni.org/onsite
Septic Tank Advisory
Certificate of On -Site Systems Approval #OSC 221049
Subdivision: Rabbit Creek View and Heights Block 10H lot 25A
Starting at 20 years of age the MOA issues Advisory's for steel septic/ STEP tanks. The septic
tank for this property is 19 years old. Potential concerns as listed on the checklist regarding the
- - -"-. baffle. and given the age are the reason for the Advisory. Typical replacement costs range from —
$11,000 to $15,000
This advisory must be attached to all copies of the subject Certificate of On -Site Systems
Approval.
This is an example of what the metal of a 20 -year-old steel tank MAY look like.
.a
r
-•• r:.
.,h
� 31
w-
!+ '•` �• � :gyp }
✓ �7 i. ti
Mailing Address: P. O. Box 196650 * Anchorage, Alaska 99519-6650 * www.muni.org
NOTE: DUE TO SNOW & ICE COVER,
THE DRIVEWAY IS APPROXIMATE.
,.Z1
�6
/ N
WELLS " .• ' ':GRAVEL �� h Lot 24A
/ RETAINING'
WALL . Qo=
ASPHALT
nA
'svh� 4.0' -_CANT lP
4.0'x19.3' c�'(0 ���
CANT
1 1' 3' N. � '• `—RETAINING
N ECS WALL
2.0'x33.5' CANT \—SEPTIC PIPES:,
Lot 26A
r
ps . Lot 25A/ K
21,027 S.F. / / Lot 17A
IN
/ / 6•Z52/ / \\
S
10' UTILITY / \
EASEMENTS /
Lot 16A
MORTGAGE SURVEY _X_ SCALE _ 1"__ 40'_ GRID SW 3341Project No. ___ 21= 852LR1
QP Associates,
� H 11500 Daryl Avenue, Anchorage, Alaska 99515-3049
Lan & s ss o c i a t e s inc. c, (907) 522-6476 Phone
9 (907) 522-4625 Fax �ooODOpo4�
Professional Land Surveyors ken®longsurvey.com o OF A( ap
Jonothan0longsurvey.com
I hereby certify that I have surveyed the following described property: �A�
LOT 25A, BLOCK 10H, RABBIT CREEK VIEW/HEIGHTS SUBDIVISION (PLAT No. 2004-91) 0 49TH
Anchorage Recording District, Alaska, and that this Mortgage Location Survey is a
representation of the conditions that were found on the date the survey was performed.
This survey does not constitute a boundary survey and is subject to any inaccuracies �•. :�ETIi.. ....NG
that a subsequent boundary survey may disclose. The information contained hereon shall 4 C o G
not be used to establish any fence, structure, or other improvemenfis. VO :sem (� O�
`n'P . LS -5202. • •' J¢ O
Dated this the _� `___ Day of __ r��� _� "�`__, at Anchorage, Alaska �QFo,o Nom
--__—� p�QROFESSIONA\-
It is the responsibility of the owner to determine the existence of any easements, �OpppoQo
covenants, or restrictions which do not appear on the recorded subdivision plat. AECC963
Municipality of Anchorage
On~Site Water & Wastewater Program
(907) 343-7904
CERTIFICATE OF ON-SITE SYSTEMS APPROVAL
02o - 5I?1- WI
Parcel I D .... 11 = ='~
1. GENERAL INFORMATION
Complete legal description
Location (site address)
Current Property owner(s)
Mailing address
Real Estate Agent
Expiration Date: ~/~ 1//,~
RABBIT CREEK HEIGHTS; BLOCK 10H~ LOT 25A
8220 ROBERT DRIVE *ANCHORAGE, AK 99516
JAMES & KAREN CUCULLU
Day phone
8220 ROBERT DRIVE *ANCHORAGE, AK 99516
C/O AGENT
DIANA WEBB W/ PRUDENTIAL
Day phone 632-0573
TYPE OF DWELLING:
· Single Family (w/wo ADU)
[] Duplex
[] Multiple Dwellings (Single Family and/or Duplex)
NUMBER OF BEDROOMS:
5
TYPE OF WATER SUPPLY:
Individual Well ·
Individual Water Storage []
Community Class Well []
Public Water System []
TYPE OF WASTEWATER DISPOSAL:
Individual On-site ·
Individual Holding tank []
Community On-site []
Public Sewer []
Received by../
COSA to be released to the engineer, unless otherwise requested by the engineer.
Date:
COSA Fee $
Date of Payment
Receipt Number
COSA#
Waiver Fee $
Date of Payment
Receipt Number
Waiver #
STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown be/ow, verify that my
investigation, based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines for this application,
shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate
for the number of bedrooms and type of structure indicated herein. I further verify, that based on the
information obtained from the Municipality of Anchorage files and from my investigation and inspection, the
on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal
and State codes, ordinances, and regulations in effect at the time of installation.
Name of Firm GARNESS ENGINEERING GROUP, Ltd.
Address 5701E. TUDOR ROAD, SUITE 101 * ANCHORAGE, AK 99507
Engineer's Printed Name JEFFREY A. GARNESS, P;E.
Engineer's Comments:
In conducting this evalubtion, GEG, LtD. attempted to provide a thorough,
conscientious engineering analysis of the system in accordance with ADEC and MOA
DSD Guidelines & Regulations. The reported results described the performance of the
system under the conditions encountered at the time of the test, and separation
distances measured to readily identifiable features. The operational life of all wells and
septic systems depend on the local soils condition, groundwater'levels thbt may
fluctuate during the year, and the water usage of the family being served by the system.
These conditions are outside the control of the evaluator of the system. Satisfactoo/ test
results do not guarantee future performance of the system, nor do they guarantee that
there are no hidden defects or encroachments. GEG, LTD. can therefore not provide
any warranty or future estimate of how long the system will continue to meet the
operational requirements of the ADEC or MOA DSD. The content of this report is for
the sole benefit of the owner listed above. Any reliance upon or use of this report by any
other person or party is not authorized, nor will it confer any legal right whatsoever.
6. DSD SIGNATURE
'~ ~ System #1 Approved for
System #2 Approved for
bedrooms.
bedrooms.
Disapproved.
Conditional approval for __
Phone 357-6179
Date
bedrooms, with the following stipulations:
' ~ 'y chomge Develop, emt Semices Division (DSD) issues Ce~ificates of On-Site Systems ~pmval (COSA) based only
upon the represenatafions given in paragr~h 5 by an independent pro~ssional civil engineer mgiste~ in the State of Alaska.
The Municipali~ of Anchorage is not responsible for errors or omissions in the professional engineeFs wo~.
7. ATTCHMENTS:
COSA Checklist
Septic System Advisory
/
(Rev 11105)
Nitrate Advisory
Arsenic Advisory
Other
Original Certificate Date:
If more than 1 septic system is on the lot:
COSA Checklist # of
Structure served by this system __
Certificate of On-Site Systems Approval Checklist
Legal Description: RABBIT CREEK HEIGHTS; BLOCK 1OH, LOT 25A Parcel ID: -8~
A. WELL DATA
Well type PRIVA'r[ IfA, B, orC provide PWSID# N/A Well Log (Y/N) YES
Date completed 7/6/03 Sanitary seal (Y/N)YES Wires propedy protected (Y/N) YES
Total depth 167 ft. Cased to 104 ft. Casing height (above ground) 24+
FROM WELL LOG AT INSPECTION
Date of test 7/6/03 11/15/12
Static water level 10 ft. 23 ft.
Well production 8 g.p.m. 4.05 g.p.m
WATER SAMPLE RESULTS:
Coliform 0 colonies/100 mi.
Arsenic: ND ug./L.
B. SEPTIC/HOLDING TANK DATA
Nitrate 0.548 mg./L.
Date of sample: 11/7/12
Tank Type/Material
Tank size 2000 gal.
Foundation cleanout/Y/N) YES
Date of pumping ~/~-~-,-~ / ~°~'
C. ABSORPTION FIELD DATA
Date installed 6/21/o3
Length 65 ft,
Total depth *9.58+
Date of adequacy test
Collected by: GEG. Ltd.
.in.
System type SHALLOW TRENCH
Gravel below pipe 4.1 ft.
STEP/STEEL Date installed 6/21/03
Numberof Compartments 2 Cleanouts (Y/N) YES
Depression over tank (Y/N) NO High water alarm (Y/N)
pBELOW EXISTING GRADE]
Soil rating (~r ff~/bdrm) 1.2
Width 5 fi,
ft. Eft. absorption area 630 ft2 Monitoring tube YES
11/15/12 Results (Pass/Fail) PASS
Fluid depth in absorption field before test 26.5 in. Water added 750 gal.
Elapsed Time: 120 min. Final fluid depth 32 in. Absorption rate >=
Any rejuvenation treatment (past 12 mo.) (YIN & type) NONE
Depression over field NO
For 5 bedrooms
New depth 35 in.
750+ g.p.d.
If yes, give date -
D. LIFT STATION
Date installed 6/21/'03
"Pump on" level at 39 in.
Datum BOTTOM OF TANK
E. SEPARATION DISTANCES
SEPARATION DISTANCES FROM WELL ON LOT TO:
Septic tank/lift station on lot 100'+
Absorption field on lot 100'+
Public sewer main N/A
Sewer/septic service line 25'+
Animal containment areas. 50'+
Size in gallons 2000
"Pump off" level at 39 in.
Cycles tested. 3
Manhole/Access (Y/N) YES
High water alarm level at 45 .in.
Meets alarm & circuit requirements? YES
On adjacent lots. 100'+
On adjacent lots 100'+
Public sewer manhole/cleanout N/A
Holding tank N/A
Manure/animal excrete stsrage areas 1 O0%
SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO:
Building foundation 5'+ Property line 5'+
Water main N/A Water service line. 10'+
Wells on adjacent lots 100'+
SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO:
Property line 10'+ Building foundation. 10'+
Water service line 10'+ Surface water 100'+
Curtain drain NONE KNOWN Wells on adjacent lots 100'+
F. COMMENTS
Absorption field 5'+
Surface wetar. 100'+
Water main N/A
Driveway, perking/vehicle storage 10'+
G. ENGINEER'S CERTIFICATION
I certify that I have determined through field inspections and
review of Municipal records that the above sys~rns are in
conformance with MOA COSA guidelines in effect on this
date.
Engineer's PdntadName JEFFREY A. GARNESS
Date " /l '~l /[~'
(Rev. 11/05)
GARNESS ENGINEERING GROUP, Ltd
CONS[JLTANT$ & G~NEF:AL CONTRACTORS
To whom this may concern:
The interior alam~ at 8220 Robert Drive will be fixed by Beeks Contracting. Garness
Engineering will assure this gets done. Please contact us with any questions. Thank you.
P.E.
3701 E. Tudor Road, Suite I01 * Anchorage, AK 99507-1259
Ph: (907) 337-6179 * Fax: (907) 338-3246 * Website: www.garnessengineering.com
Municipality of Anchorage
Development Services Department
Building Safety Division
On-Site Water & Wastewater Program
4700 South Bragaw St.
P.O. Box 196650 Anchorage, AK 99519-6650
www.ci.anchorage.ak.us
(907) 343-7904
Parcel P.D.
1.
CERTIFICATE OF HEALTH AUTHORITY APPROVAL
FOR A SINGLE FAP11LY DWELLING
020-115-50 HA,Afl
GENERAL INFORMATION Expiration Date: L.~ ~ / J,./. - O LtL
Cornplete legal description RABBIT CREEK HEIGHTS SUBDIVISION; LOT 25~ BLOCK 10~
Location (site address or directions)
Current Property owner(s)
Mailing address
Lending agency
Mailing address
Real Estate Agent
Mailing address
8220 ROBERT DRIVE * ANCHORAGE, AK 99516
JIM CUCULLU Day phone 345-354-4
8220 ROBERT DRIVE * ANCHORAGE~ AK 99,.516
Day phone
Day phone
Unlessothe~iserequeste~ HAA wNbeheldbyDSD ~rpick~.
2. NUMBEROFBEDROOMS: 5
TYPE OF WATER SUPPLY:
In~Mdual Well ·
Individual Water Storage []
Community Class .Well []
Public Water System []
TYPE OF WASTEWATER DISPOSAL:
Individual On-site ·
Individual Holding tank []
Community On-site []
Public Sewer []
The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of Health Authority
Approval (HAA) based only upon the representations given in paragraph 4 by an independent professional civil
engineer registered in the State of Alaska. Certificates of Health Authority Approval are required for the transfer
of title (except between spouses) for proper[les served by a single-family on-site wastewater disposal and/or
water supply system. DSD also issues HAAs upon request to homeowners. Certificates of Health Authority
Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may
be reissued with new water samples, (Certificates may be reissued for a period of up to one year with valid
water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water
system. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's
work.
Note: Alaska Water and Wastewater Consultants, Inc. shall be paid $ at, or pdor
to closing for the engineering services provided.
4. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my
investigation, based on procedures outlined in the Health Authority Approval Guidelines for this application,
shows that the on-site water supply and/or wastewater disposal system is(are) safe, functional and adequate
for the number of bedrooms and type of structure indicated herein. I further verify that based on the
information obtained from the Municipality of Anchorage files and from my investigation and inspection, the
on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal
and State codes, ordinances, and regulations in effect at the time of installation.
Name of Firm ALASKA WATER & WASTEWATER CONSULTANTS, INC. Phone 557-6179
Address 5701 E. TUDOR ROAD, SUITE 101 * ANCHORAGE¢ AK 99507
Engineer's Printed Name JEFFREY A. OARNESS, P.E. Date
Engineer's Comments:
In conducting this evaluation, AKWWC, Inc. attempted to provide a thorough,
conscientious engineering analysts of the system in accordance with ADEC and MOA
DSD Guidelines & Regulations. The reported results described the performance of the
system under the conditions encountered at the time of the test, end separation
distances measured to readily identifiable features. The operational life of all wells and
septic systems depend on the local soils condition, groundwater levels that may
fluctuate during the year, and the water usage of the family being served by the system.
These conditions are outside the control of the evaluator of the system. Satisfactory test
results do not guarantee future performance of the system, nor do they guarantee that
there are no hidden defects or encroachments. AKWWC, Inc. can therefore not provide
any warranty or future estimate of how long the system will continue to meet the
operational requirements of the ADEC or MOA DSD. The content of this report is for
the sole benefit of the owner listed above, Any reliance upon or use of this report by any
other person or party is not authorized, nor will it confer any legal right whatsoever.
5. DSD SIGNATURE
V""' Approved for ~ bedrooms.
Disapproved.
Conditional approval for
bedrooms, with the fllowing stipulations:
ON-SffE :
- WASTEWATER ·
Attachments:
HAA Checklist
Septic System Advisory
Well Flow Advisory
p ROG
Manltenance Agreements %':~ O~'
Suppleme,tal Engineer s Reo. 7);~ I., ~;,;,,"
Other
{Rev. 12101)
Original Certificate Date:
I-1 /
Municipality of Anchorage
Development Services Department
Building Safety Division
On-Site Water & Wastewater Program
4700 South Bragaw St.
P.O. Box 196650 Anchorage, AK 99519-6650
www.ci.anchorage.ak.us
(907) 343-7904
Legal Description:
A. WELL DATA
Well type PRIVATE IfA, B, or C provide PWSID# N/A
Date completed 7/6/2003 Sanitary seaI(Y/N).YES
Totaldepth 167 ft. Cased to 104 ft.
Date of test
Static water level
Well production
WATER SAMPLE RESULTS:
Coliform 0 colonies/100 mi.
Arsenic: N/A mg./L.
HEALTH AUTHORITY APPROVAL CHECKLIST
RABBIT CREEK HEIGHTS S/D; LOT 25, BLOCK 10, Parcel ID:
FROM WELL LOG
7/5/2005
10 fl.
6 g.pm.
Well Log (Y/N)
Wires properly protected (Y/N)
Casing height (above ground)
AT INSPECTION
gp.m
Nitrate 0.46 mg./L. Other bacteria__
Date of sample: 12/16/2003 Collected by:
B. SEPTIC/HOLDING TANK DATA
Tank Type/Material STEEL/S.T.E.P.
Tank size 2000 gal. Number of Compartments __
Foundation cleanout (Y/N) YES
Date of pumping NEW
C. ABSORPTION FIELD DATA
Date installed 6/21,/2003
Length 63 .ft.
2
Depression over tank (Y/N) NO
Pumper.
~BELOW FINAL GEADEI
Soil rating Or ft~/bdrm) 1.2
Widih 5 ft.
Total depth *6.98 ft. Eft. absorption area 650 ft2 Monitoring tube YES
Date of adequacy test NEW Results (Pass/Fail) PASS
Fluid depth in absorption field beforetest - in.
Elapsed Time: - min. Final fluid depth -
Any rejuvenation treatment (past 12 mo.) (Y/N & type)
020-113-50
YES
YES
24 in.
0 colonieS100 mi.
AKWWC, INC.
Date installed 6/21/2003
Cleanouts (Y/N) YES
High water alarm (Y/N) YES
System type SHALLOW TRENCH
Gravel below pipe 4.1 ft.
Depression over field NO
For 5 bedrooms
Water added - gal. New depth - in.
in. Absorption rate >= - g.p.d.
- If yes, give date -
D. LIFT STATION
Date installed 6/21/2003
"Pump on" level at 59 in.
Datum BOTTOM OF TANK
Size in gallons 2000
"Pump off" level at 39 in.
Cycles tested NEW
Manhole/Access (Y/N) YES
High water alarm level at 45 in.
Meets alarm & circuit requirements? YES
E. SEPARATION DISTANCES
SEPARATION DISTANCES FROM WELL ON LOT TO:
Septic tank/lift station on lot100'+
Absorption field on lot 100'+
Public sewer main N/A
Sewer/septic service line 25'+
On adjacent lots 100'+
On adjacent lots 100'+
Public sewer manhole/cleanout
Holding tank N/A
N/A
SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO:
Building foundation 5'+ Property line 5'+ Absorption field
Water main N/A Water service line. 10% Surface water
Wells on adjacent lots 100'+
100%
SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO:
Property line 10'+
Water service line 10'+
Curtain drain NONE KNOWN
Building foundation 10'+
Surface water 100'+
Wells on adjacent lots 100'+
Water main N/A
Driveway, parking/vehicle storage
10'+
F. COMMENTS
G. ENGINEER'S CERTIFICATION
I certify that I have determined through field inspections and
review of Municipal records that the above systems are in
conformance with MOA HAA guidelines in effect on this date.
Engineer's Printed ~lame
Date
JEFFREY A. GARNESS
Waiver Fee $
Date of Payment
Receipt Number
ALASKA WATER & WASTEWATER
CONSULTANTS, INC.
January 13, 2004
Municipality of Anchorage
Development Service Department
Building Safety Division
On-Site Water & Wastewater Program
P.O. Box 196650
Anchorage, Alaska 99519-6650
Ref: Driveway location for Lot 25, Block 10; Rabbit Creek Heights Subdivision.
To whom it may concern:
It was noted by your department that the as-built drawing by Robert T. Kean showed the well in
the driveway. A site visit by our firm shows the well approximately 4-5 feet from the driveway.
The well is also 2-3 feet higher in elevation then the ch'iveway. It is our assumption that the
driveway locatio~3~on Robert T. Kean's as-built is not accurate. If you have m~y questions, please
contact us at 337-~179. Thank you for yonr assistance.