HomeMy WebLinkAboutFOREST VIEW HEIGHTS LT 1 & 2Forest View H ights Lot ! &2 #014-141-86 Municipality of Anchorage Page 1 of 3 DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 · Anchorage, Alaska 99519-6650 · Telephone: 343-4744 On-Site Wastewater Disposal System and/or Well Inspection Report Permit Number: .qwqyn174 PIDNumber: · 0141 41 28 ..m.: Wastewater System: [] New [~pgrade Mayo T. Wells ^ddt--: ABSORPTION FIELD 3338 E. 72nd Avenue Phone: 344-1089 tN°'°f Bedrooms:6 ~p Trench [] Shallow Trench [] Bed [] Mound [] Other Total Depth from original grfldg: LEGAL DESCRIPTION So,,R.t,ng: //2-- ~,~,~.Ft. ' //.~ ' ~T/I~ ~r~. ~. i ~,. , ~ ~t. Townahip: I Range: I ~ctlon: Fill edd~ i~ve original grade: Gravel length: ~ Ft. ~, D Et I I WELL: ~. D New D Upgrade Gravel width: Num.rof lines: Di~~: ~ ' Ft. ~ ~ Ft. Clarification (Pr~ate, A,B,C): Total Depth: ~ To: To~l abao~tlon ama: PI~ material: ~T~ Ft. Ft. ~7~ SO. ~. SEPARATION DISTANCES ~.,,c s Holding 0 S.T.E.P. TO Septic Ab~tl~ L~ Holding ~t~ Manufacturer: CapaclW tn gallons: Weir I~ ~ I ~%. O ~ ~ ~, Mate~ Num~r~of Compa.men~: su,,~,w~,~ >~' >/o~' ~ ~ >~' LIFT STATION Line ~ / / ~. pi S~*,n gallons: Manufacturer: Cu~ain Drain ~¢ ~ 'mP M~ I Electri~l Ins'cti°ns ~°~ed bY: BENCH MARK Remarks: ~xis~i~9 sep[ic sys[em vas crushed, backfilled and aban- c~(t~ <,,~ doned in place. ~ ~. A~umed Elevation: ENGINEER'S SEAL Inspections pedormed by: ~' Dates: 1st ~//~ 2nd 7/,7/~ ~ ,'~"---"':- ..... Depadment of Hea~ and Human Se~ices approval '/ ~ Date: ~ Reviewe ana app ovea by J Permit No. SW970174 Pege 2 of 3 Municipality of Anchorage DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P.O, Box 196650 · Anchorage, Alaska 99519-6650 · Telephone: 343-4744 On-Site Wastewater Disposal System and/or Well Inspection Report Legal Description: Lot 1, Forest View Heiqhts PIDNo.: 01414128 SP1 Septic Pump, ~ompa~tment 1 SP2 " " 2 C Clean Out MT Monitor Tube Permit No. SW970174 Page 3 of 3 Municipality of Anchorage DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 · Anchorage, Alaska 99519-6650 · Telephone: 343-4744 On-Site Wastewater Disposal System and/or Well Inspection Report Legal Description: Lot 1. Forest View }{eights PID No.: 01414128 I"= PAGE 1 OF 1 MUNICIPALITY OF kNCHORAGE DEPARTMENT OF HEALTH AND HUMAN SERVICES P.O. BOX 196650, 825 "L" STREET, ROOM 502 ANCHORAGE, ALASKA 99519-6650 ON-SITE WASTEWATER DISPOSAL SYSTEM (UPGRADE) PERMIT PERMIT NUMBER:SW970174 DESIGN ENGINEER:ANDERSON ENGINEERING OWNER NkME:WELLS MAYO T OWNER ADDRESS:3338 E 72ND AVE ANCHORAGE, ALASKA 99507 DATE ISSUED: 7/08/97 EXPIRATION DATE: 7/08/98 PARCEL ID:01414128 LEGAL DESCRIPTION: FOREST VIEW HEIGHTS LT 1 LOT SIZE: 8349 (SQ. FT.) NUMBER OF BEDROOMS: 6 THIS PERMIT: 6 THIS PERMIT IS FOR THE CONSTRUCTION OF: DISPOSAL FIELD /SEPTIC TANK SYSTEM ALL CONSTRUCTION MUST BE IN ACCORDANCE WITH: 1. THE ATTACHED APPROVED DESIGN. 2. ALL REQUIREMENTS SPECIFIED IN ANCHORAGE MUNICIPAL CODE CHAPTERS 15.55 AND i5.65 AND THE STATE OF ALASKA WASTEWATER DISPOSAL REGULATIONS (18AAC72) AND DRINKING WATER REGULATIONS (18AAC80) . 3. THE ENGINEER MUST NOTIFY DHHS AT LEAST 2 HOURS PRIOR TO EACH INSPECTION. PROVIDE NOTIFICATION BY CALLING 343-4744 ( 24 HOURS ) (NOT REQUIRED FOR WELL ONLY PERMIT) 4. FROM OCTOBER 15 TO APRIL 15 A SUBSURFACE SOIL ABSORPTION SYSTEM UNDER CONSTRUCTION DURING FREEZING WEATHER MUST BE EITHER: A. OPENED AND CLOSED ON THE SA_ME DAY B. COVERED, SEALED AND HEATED TO PREVENT FREEZING 5. THE FOLLOWING SPECIAL PROVISIONS. SPECIAL PROVISIONS: RECEIVED BY: ~t~. ~__~ DATE: DATE: Rick Mystrom, Mayor Mtmicipality of Anchorage Department of Health and Human Services $25 "L" Street P.O. Box 196650 Anchorage, Alaska 99519-6650 July 9, 1997 Michael E. Anderson, P.E. Anderson Engineering PO Box 240773 Anchorage, Alaska 99524 Subject: Waiver Request for Lots 1, 2, 3 Forest View Heights Subdivision Waiver Request #WR970028 , PID #041-141-28, SW970174 Dear Mr. Anderson: Your request for a waiver of the required 10 foot separation between an on-site wastewater disposal system and a lot line has been approved. The waived distance is 2 feet from the trench to the south property lined. This approval applies to the existing on-site wastewater disposal system lot line separation only. Any future upgrade to the on-site wastewater disposal system will require all separations be met or another approval from this department. If there any further questions or concerns regarding this waiver, please call our office at 343-4744. Sincerely, Daniel J. Roth On-site Services ljw #7 Wells MUNICIPALITY OF ANCHORAGE Department of Health and Human Services On-site Services Section Waiver Review Worksheet WR# WR970028 PID~ 041-141-28 HA# Date Received: June 19~ t997 Legal Description: Lots 1~2~3m Forest View HeiKhts Engineer: Michael E. Anderson, P.E., ANderson En~ineerin~ PO Box 240773, Anchorage, Alaska 99524 Applicant: Mayo T. Wells Permit Waiver Requested: line. Lot line waiver of 2 foot from the trench to the south property Criteria: 1. Geology: Points: A. Water Table B. Soil Sorption C. Permeability D. Water Table Gradient E. Horizontal Separation TOTAL: Special Conditions: e 3. Other: Waiver is Granted: ~ Waiver is NOT Granted: List Conditions or Reasons for above: ~ ~.;~.~z~ ~,~-~~ Date: 7-¢-~7 By: Rec ~: 02929(9949) Amount: $ 115.00 Name of Reviewer Date Paid: 6-19-97 June 19, 1997 Municipality of Anchorage Department of Heath & Human Services 825 "L" Street Anchorage, AK 99502-0650 Subject: MUNICIPALITy OF ANCHORAGE ENVIRONMENTAL ,SERvICEs DIVISION dUN 79 1997 RECEIVED Lots 1, 2, and 3, Forest View Heights Subdivision Septic System Upgrade Lot Line W~Jver ~equest Dear On Site Services Engineer: The attached Site Plan shows the location of the proposed septic system to be constructed on the subject lot to replace the failing absorption crib. Very little area is available for the new system because of the location of the well on the property. We are therefore requesting a waiver to place the trench within 2' of the lot line. No easements exist along the property line where the new trench will be constructed. In addition, no development falls within 30' of the adjoining property to the south. The septic system can be constructed to maintain 100' separation from all wells in the area only if the lot line waiver is granted. Please let me know if you have additional questions. Sincerely, Michael E. Anderson, P.E. LOTS 1, 2, 3, FOREST VIEW HTS. 2,000 GALLON SEPTIC TANK 75' LONG X 5' WIDE X 4/ EFFECTIVE DEPTH TRENCH SITE PLAN SCALE 1" = 30' NOTE: EXISTING TANK AND CRIB TO BE PUMPED, CRUSHED, FILLED WITH SAND AND ABANDONED IN PLACE. June 19, 1997 Municipality of Anchorage Department of Heath & Human Services 825 "L" Street Anchorage, AK 99502-0650 Subject: Lots 1, 2, and 3, Forest View Heights Subdivision Septic System Design Impacts to Adjacent Properties Dear On Site Services Engineer: We hereby apply for a permit to construct a new septic system on Lots 1, 2, and 3, Forest View Heights Subdivision. The existing absorption crib is near failure and the tank is currently located within the protective radius of the well. Both the crib and the tank will be pumped, crushed and backfilled with sand prior to abandonment. The attached Site Plan shows the location of the new septic tank and trench. Due to the size of the lot and the placement of the well the only area available for the new absorption trench is within 2' of the lot line. A lot line separation distance waiver is therefore required and attached to this package. Testholes performed on the property revealed clean poorly graded sands which percolated at 3 minutes per inch. We have designed the absorption trenches for an absorption rate of 1.2 gallons per day per square foot. Total depth of the system will be 12'. No groundwater was encountered during excavation for the testholes nor was any noted during the monitoring period. The surface of the lot slopes from south to north at a very gently grade of approximately 1%. The surface of the ground in the area of the absorption trench is fairly flat. / If the system is constructed as designed the following statements can be made: The system, if constructed as designed, will have no adverse impact on the wells in the area or those to be constructed in the future. Lots 1, 2, and 3, Forest View Heights Subdivision June 19, 1997 Page Two o The system, if constructed as designed, will have no adverse impact on existing septic systems in the area or those to be constructed in the future. The system, if constructed as designed, will have no adverse impact- on reserved space, either surface or subsurface, on any lots located in the area. The system, if constructed as designed, will have no adverse impact on drainage patterns in the area. The current drainage pattern will be maintained. Sincerely, Michael E. Anderson, P.E. Attachments LOTS 1, 2, 3, FOREST VIEW HTS. 2,000 GALLON SEPTIC TANK e-, , · ' ,. 75' LONG X 5' WIDE X 4' ~.. , .,. , \ ~, ~ r.~,~,?,:;. ;: ,;, EFFECTIVE DEPTH TRENCH ,~,. ~::,~.-, .,~ 'E PLAN SCALE 1" = 30' NOTE: EXISTING TANK AND CRIB TO BE PUMPED, CRUSHED, FILLED WITH SAND AND ABANDONED IN PLACE, LOTS 1, 2, 3, FOREST VIEW HEIGHTS SUBDIVISION, DESIGN FACTORS: Six Bedroom Home Perc. Rate: ~3 Min./Inch Application Rate: 1.2 GPD/SF SYSTEM REQUIREMENTS: Wide Trench Systen~ 2,000 Gallon Septic Tank 4' Drainfleld Rock 6 Bedrooms X 150 GPD / 1.2 GPDISF = 750 SF of Absorption Area 750 SF/5 LF (Trench Bottom) X .5 (Red. Factor) = 75 LF Trench Length Therefore: Construct a 5' Wide Absorption Trench With One Lateral 75' in Length. Distribution Pipe in Trench Placed at 8.0' Below the Original Ground Surface. NOTE: TYPICAL WIDE TRENCH SECTION (NO SCALE) Grade Area Over Trench to Drain Away. ~~~' Maintain 4' Vertical Separation From Ground Water. Muni~,lpaiity of Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L" Street, Anchorage, Alaska 99502-0650 SOILS LOG -- PERCOLATION TEST PERFORMED FOR: LEGAL DESCRIPTION: Lots 1-3 t Mayo Wells 1 2, 3- 7 10 13- 14- 18- Forest,View Heights Subd. Township, Range, Section: SLOPE / WAS GROUND WATER ENCOUNTERED? IV SITE PI. AN F~.,, IF YES, AT WHAT ~ 0 Grins Net {~p[h to Net R#dln~ Da~e Time Time Water Omi= PERCOLATION RATE (mJnute~nch) PERC HOLE DIAMETER COMMENTS TEST RUN B~ETWEEN __, FT AND __. FT 72-008 (Rev, 4/85) PERFORMED FOR: LEGAL DESCRIPTION: Lots 10 11 12 13 ~ ~'""'~'~ '¢'- 16- 17- 18- 19- Munictl~iil~ ol Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 825 'L" Street, Anchorage, Alaska 99502-0650 SOILS LOG -- PERCOLATION TEST Mayo Wells Forest, View Township, Range, Section: Heights Subd. SLOPE WAS GROUND WATER ENCOUNTERED? $ DEPTH? P PERCOLATION RATE ~'~ (mmute~mcfl) PERC HOLE DIAMETER TF~T RUN BETWEEN ~7.~ FT AND ._~.~ FT ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE 72-008 {Rev. 4/~) GRr~TER ANCHORAGE AREA BOROUmH HEALTH DEPARTMENT 327 EAGLE ST. ANCHORAGE, ALASKA 99501 279-2511 INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM LOCATION SEPTIC TANK: MAILING ADDRESS LEGAL DESCRIPTION PHONE/d J:? DISTANCE FROM WELL J LIQUID CAPACITY Jo. z- ~:' GALLONS. ~ NUMBER OF MATERIAL c ',.-.- ',.-' ~-~'~'..~---'~:'~- COMPARTMENTS INSIDE LENGTH ~ INSIDE WIDTH '~- LIQUID DEPTH SEEPAGE SYSTEM: SEEPAGE PIT: NUMBER OF PITS LINING MATFRIAI,.~' ~'-~' NEAREST LOT LINE__ OdTSIDE DIAMETER ~ OR WIDTH ~' ']- (- ~ ~ /'""~ Y"-) DISTANCE FROM WELL // .,.~2~. '/ ~OTAL EFFECTIVE ABSORPTION AREA {WALL AREA) , LENGTH ~'...~2 , DEPTH , BUILDING FOUNDATION-",/~ ''~ /'7~ ~ ~ SQ. FT. TILE DRAIN FIELD: DISTANCE FROM WELL ~ NUMBER OF L1NES A BSORf)TIO N AREA E~['PTH: TOP OF TILE TO FINISH GRADE - "~, FOUNDATION ..-"/"'"~' NEARE S(~. FT. LENGIH.~ EACH LINE DEPIH OF FILTER MATERIAL BENEATH TILE TOTAL LENGTH OF L I ixJ.EB~- ---.,, .--" IN. TOTAL EFFECTIVE IN. ABOVE TILE DISTANCE FROM WELL: TYPE/--'..~',~'z~=~? , DEPi'H ./."z' .A'''z ,BUILDING FOUNDATION NEAREST ~ SEPTIC jr.,.~z~/ SEEPAGE LOT LINE .- ,z ' ~-' , SEWER LINE , lANK , SYSTEM ...~? ~ WATER ~.,~ SAMPLE · -/'"'~': , CESSPOOL DIAGRAM OF SYSTEM , NEAREST OTHER , SOURCES DISTANCES: r_ - ' '//> /~' APPROVED ~ ' ' ' ~ % HEALTH AUTHORIIY GAAB-HD-2 GREATEF 327 Eagle St. NCHORAGE AREA r )ROUGH HEALTH DEPARTMENT Anchorage, Alaska 99501 279-2511 Case No. ~ SEWAGE DISPOSAL SYSTEM - APPLICATION & PERMIT ; ~//"~ MAILING ADDRESS ,J'- '-, ' . ,, PHONE NO .... ,'. " ' - ,.~'~' LOCATION OF INSTALLATION NAME OF APPLICANT,,~;~'' RESIDENCE AOBRESS~" ' LEGAL DESCRIPTION ,: APPLICATION TO INSTALL: SEPTIC TANK, ,":,:- TO SERVE THE FOLLOWING FACILITY FINANCED THROUGH PERCOLATION TEST RESULTS , SEEPAGE PIT. , DRAIN FIELD TO BE INSTALLED BY i' ANTICIPATED DATE OF COMPLETION , OTHER BELOW TO BE FILLED OUT BY HEALTH DEPARTMENT THIS IS TO SERVE AS AS DESCRIBED BELOW. · SEPTIC TANK SIZE DISTANCES: , PERMIT TO INSTALL A SIZE OF UNIT TO BE SERVED TYPE SEEPAGE AREA DIAGRAM OF SYSTEM TYPE I certify that I am familiar with the requirements of Greater Anchorage Area Borough Ordinance No. 28-68 and that the above described system is in accordance with said code. DATE~ :,_ , - APPLICANTS SIGNATURE .~. ~"..).~ z , ... ~'~ /_ MUMUPAUTY OF ANCHORAGE Development Services Department ` Phone. 907-343-7904 On -Site Water & Wastewater Section Fax: 907-343-7997 Certificate of On -Site Systems Approval Parcel I.D. 014-141-86 1. GENERAL INFORMATION Expiration Date: J— I L - 26 2 :7 Complete legal description Forest View Heights Lot 1+2 Location (site address) 3338 E 72nd Avenue Current property owners) Terry Lammers Mailing address Real estate agent 2. TYPE OF DWELLING: El Single Family (w/wo ADU) ❑ Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) 3. NUMBER OF BEDROOMS: 6 Day phone Day phone 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Private Well Q Private Septic 0 Water Storage ❑ Holding Tank ❑ Community Well ❑ Community ❑ Public Water System ❑ Public Sewer ❑ Waiver request for: Distance: Received by: Date: COSA to be released to the engineer, unless otherwise requested by the engineer. COSA Fee $ 5 50 Date of Payment i b D-� Receipt Number 03 f 31 G COSA# 05G22J26 Waiver Fee $ Date of Payment Receipt Number Waiver # 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is (are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. In conducting an adequacy test, I attempt to provide a thorough, conscientious engineering analysis of the system in accordance with MoA COSA guidelines and regulations. The reported results describe the performance of the system under the conditions encountered at the time of the test, and separation distances measured to readily identifiable features. The operational life of all wells and septic systems depend on the local soil condition, ground water levels that may fluctuate during the year, and the water usage of the family being served by the system. These conditions are outside the control of the evaluator of this system. All systems eventually fail and satisfactory test results do not guarantee future performance of the system, nor do they guarantee that there are no hidden defects or encroachments. Therefore we cannot provide any warranty for future performance, nor can we estimate remaining life of the system. The content of this report is for the sole benefit of the owner listed above. Reliance on this report by another person is at their own risk. Pannone Engineering Services LLC highly recommends buyers hire their own engineer to evaluate this report. Name of Firm Pannone Engineering Services Phone (907) 745-8200 Address P.O. Box 1807 Palmer, AK 99645 Engineer's Printed Name Steven R. Pannone P.E. Date OF F A `` DSD SIGNATURE ' TH .... anno . System #1 Approved for � bedrooms � Steven R. • re• onno r, CE 8149 System #2 Approved for bedrooms�`�sl Disapproved Conditional approval for bedrooms, with the following stipulations: WQPOTY pF�r��ii 44, Ali nA, tion'. oAT ER c, m pATE;q 5. m - Ji�IiJTSERVICES,.��`�\ BOriginal Certificate Dater Z The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: COSA Checklist X Septic System Advisory Well Flow Advisory COSA Checklist blue sheet Nitrate Advisory Arsenic Advisory Other 110 V� Legal Description: Forest View Heights Lots 1+2 Parcel ID: 614-141-86 If more than 1 septic system on tot: COSA Checklist # 1 of 1 Structure served by this system 1 A. WELL DATA _1 Well log is filed with Onsite (or attached) Date drilled PNE 19i< Total depth 45+ ft Cased to 45+ ft ❑ Sanitary seal is functioning correctly ❑ Wires are properly protected Casing height (above ground) 16.5 in. Date of flow test for COSA 05/13122 Static water level at beginning of test 44.2 ft. Comments Unknown Well Depth B. TANK DATA Age of tank(s) 7"5`97 years Tank type/material SEPTIC.WEE Measured operating fluid level in septic tank $" ❑ Standpipes/foundation cleanout per record drawing Date of pumping D. ABSORPTION FIELD DATA Deep Trench Which system tested (date installed) 7116197 ❑ ALL standpipes present per record drawing Total measured depth from grade 11.9 ft (max) Measured depth to pipe invert from grade 8 ft (min) ❑ N/A — pressurized field ❑ Monitor tubes go to bottom of effective. If not, state depth into effective 3.7',4.25' ❑ Code -required soil cover over field ❑ System presoaked _- (Required if vacant f eater than�3l�d s prior to date of test) Gallons intro uced �+� �4:allons Comments/Defi iencies: COSA Checklist yellow sheet Well production at time of test 4.36 gpm Water storage tank volume NSA gallons Well disinfected for coliform test? ❑ Yes [QNo Coliform bacteria is Negative Nitrate � W % mg/L ❑ Nitrate less than MRL (ND) Arsenic ug/L pisisenic less than MRL (ND) Collected by FL S Date of Sample 05/13/22 , C. LIFT STATION' ❑ Required maintenance completed Age of lift station NSA years Lift station material Comments: Adequacy test date 05/13/22 Results Q Pass For 6 bedrooms Fluid depth 0 in Wat added O gal New depth in Elapsed time 43 min Final fluid depth 0 in Absorption rate 900 gpd Any rejuvenation treatment (past 12 months) If yes, enter date E. SEPARATION DISTANCES From Private Well on Lot to: (Please enter distances if less than required or if community well) Septic Tank/Lift Station on Lot > 100' 0 Yes Community Sewer Manhole/Cleanout > 100' Q Yes if No ft Q Yes if No ft Neighboring Tank > 100' [) Yes if No ft Private Sewer/Septic Line > 25' Fv-1 Yes if No ft Absorption Field on Lot > 100' [] Yes if No ft Holding Tank > 100' Q Yes if No ft Neighboring Absorption Fields > 100' M Yes if No ft Water Main > 10' Animal Containment > 50' 0✓ Yes if No ft 0 Yes if No ft M Yes if No ft Water Service Line > 10' [] Yes if No Manure/Animal Excreta Storage > 100' If septic tank is,under driveway Community Sewer Main > 75' Q Yes if No ft 0✓ Yes if No ft From Septic/Holding Tank on Lot to: (Please enter distances if less than required) Building Foundations > 10' 0 Yes if No ft Surface Water > 100' Yes if No ft Property Line > 5' El Yes if No ft Wells on Adjacent Lots: ft Absorption Field > 5' [✓ Yes if No ft Private Wells > 100' M Yes if No ft Water Main > 10' Q Yes if No ft Community Wells > 200' M Yes if No ft Water Service Line > 10' [] Yes if No ft If septic tank is,under driveway comment below From Absorption Field on Lot to: (Please enter distances if less than required) Building Foundation > 10' Il Yes if No ft If absorption field is under driveway comment below Property Line > 10' ❑ Yes if No 2* ft Wells on Adjacent Lots: Water Main > 10' 0 Yes if No ft Private Wells >100' _ ❑Yes if No ft Water Service Line > 10' Q Yes if No ft Community Wells > 200' ❑ Yes if No ft Surface Water > 100' 0 Yes if No ft F. ENGINEER'S COMMENTS * SEE EXISTING LOT WAIVERS ON FILE G. ENGINEER'S CERTIFICATION l certify that / have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this date. z, COSA Checklist yellow sheet OF AL;k k ��.• � — .via Steven .P,. •75aniionc- CE 8149 c�o Septic 'Tank Advisory Certificate of On -Site Systems Approval #OSC221264 Subdivision: Forest View Heights Lot 1 & 2 Starting at 20 years of age the MOA issues Advisory's for steel septic tanks. The septic tank for this COSA / property is 25 years old. A leaking septic tank may be a source of contamination to the aquifer. Typical replacement costs range from $10,000 to $15,000 This advisory must be attached to all copies of the subject Certificate of On -Site Systems Approval. This is an example of a 16 -year-old septic tank in failure and should be replaced. Ma�lmg Address P C1 Box 196650 *Anchorage, Alaska 99519 6650 *www muni org Municipality of Anchorage On-Site Water & Wastewater Program CERTIFICATE OF ON-SITE SYSTEHS APPROVAL Parcel l.D 014-141-86 1. GENERAL INFORMATION Expiration Date: Complete legal description Location (site address) Current Property owner(s) Mailing address Real Estate Agent FOREST VIEW HEIGHTS LOT 1 ~ ~ 3338 EAST 72ND *ANCHORAGE, AK 99507 GARY &: PAMELA DEPUE Day phone 3338 EAST 72ND *ANCHORAGE, AK 99507 JOHN COLLINGE W/ PRUDENTIAL Day phone 2. TYPE OF DWELLING: · Single Family (w/wo ADU) [] Duplex [] Multiple Dwellings (Single Family and/or Duplex) 3. NUMBER OF BEDROOMS: 6 4. TYPE OF WATER SUPPLY: Individual Well · Individual Water Storage [] Community Class Well [] Public Water System [] TYPE OF WASTEWATER DISPOSAL: Individual On-site · Individual Holding tank [] Community On-site [] Public Sewer [] Received by: /'~.¢' COSA to be released to the engineer, unless et hen,vise requested by the engiaeer, COSA Fee $ Date of Payment Receipt Number COSA ~ ~l Waiver Fee $ Date of Payment Receipt Number Waiver # 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedreoms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm GARNESS ENGINEERING GROUP, Ltd. Phone 537-6179 Address 3701 E. TUDOR ROAD, SUITE 101 * ANCHORAGE, AK 99507 Engineer's Printed Name JEFFREY A. GARNESS, P.E. Date Engineer's Comments: In conducting this evaluation, GEG, LtD. attempted to provide a thorough, conscientious engineering analysis of the system in accordance with ADEC and MOA DSD Guidelines & Regulations. The reported results described the performance of the system under the conditions encountered at the time of the test, and separation distances measured to readily identifiable features. The operational life of all wells and septic systems depend on the local soils condition, groundwater levels that may fluctuate during the year, and the water usage of the family being served by the system. These conditions are outside the control of the evaluator of the system. Satisfactory test results do not guarantee future perfonDance of the system, nor do they guarantee that there are no hidden defects or encroachments. GEG, LTD. can therefore not provide any warranty or future estimate of how long the system will continue to meet the operational requirements of the ADEC or MOA DSD. The content of this report is for the sole benefit of the owner listed above. Any reliance upon or use of this report by any other person or party is not authorized, nor will it confer any legal right whatsoever. 6. DSD SIGNATURE Y System #1 Approved for System #2 Approved for Disapproved. Conditional approval for __ bedrooms. bedrooms. bedrooms, with the following stipulations: ON-SiTE WATER AND The Municipality or Anchorage Develop,emt Services Division (DSD) issues Ceflificates of On-Site Systems Approval (COSA) based only upon the represenatations given in paragraph 5 by an independent professional civil engineer registered in the Slate of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineeFs work. 7. ATTCHMENTS: COSA Checklist Septic System Advisory Well Flow Advisory (Rev 1155) Nitrate Advisory Arsenic Advisory Other ?,,~ Original Certi~Jc~[e If more than 1 septic system is on the lot: COSA Checklist # of Structure served by this system __ Certificate of On-Site Systems Approval Checklist Legal Description: A. WELL DATA Well type PRIVATE FOREST VIEW HEIGHTS LOT 1 ~ ~-- Parcel ID: *INSPECTED BY APWS-SEE PRIOR COSA IfA, I~, or C provide PWSID# N/A Well Log (Y/N) 014-141-86 NO Date completed PRE 1974 Sanitary seal (Y/N) YES Total depth *45+ ft. Cased to *45+ ft. FROM WELL LOG Date of test NO WELL LOG Static water level J ft. Well production ,,,-/ g.p.m WATER SAMPLE RESULTS: Coliform ¢-~ colonies/100 mi. NitrateO"~O(ffmg.lL. Ar'senic:/kJ O ug./L. Date of sample: 1/9/1,3 B. SEPTIC/HOLDING TANK DATA Tank Type/Material SEPTIC/STEEL Tank size 2000 gal. Numberof Compartments 2 Foundation cleanout (Y/N) YES Depression over tank (Y/N) NO Date of pumping 7/20/12 Pumper C. ABSORPTION FIELD DATA [*BELOW EXISTING GRADE] Date installed 7/16-17/97 Soil rating (g.p,d./ft2or~ 1.2 Length 67 ft. Width 5 ff. Total depth '12,50 ff. Eft. absorption area 670 ft~ Monitoring tube YES Date of adequacy test 1/8/13 Results (Pass/Fail) PASS Fluid depth in absorption field before test 21 in. Water added 1970ga1. Elapsed Time: 980 min. Final fluid depth 20 in. Any rejuvenation treatment (past 12 mo.) (Y/N & type) NONE Wires properly protected (Y/N) Casing height (above ground) AT INSPECTION 1/8/13 44 ft. 9.73 g.p.m. Collected by: GEG. Ltd, Date installed 7/16-17/97 Cleanouts (Y/N) YES High water alarm (Y/N) N/A ONE STOP SERVICES Absorption rate >= YES 12+ .in. System type TRENCH Gravel below pipe 4.2 .ft. Depression over field NO For 6 bedrooms New depth 29 in. 900+ g.p.d. If yes, give date - D. LIFT STATION Date installed Size in gallons ~ ~ "Pump on" level at ~ High water a arm level at ~n. ~ ~ Cycles tested. Meets alarm & circuit requirements? E. SEPARATION DISTANCES SEPARATION DISTANCES FROM WELL ON LOT TO: 100'+ Septic tank/lift station on lot Absorption field on lot 100'+ Public sewer main 75'+ Sewer/septic service line 25% Animal containment areas 50% On adjacent lots. 100'+ On adjacent lots 100'+ Public sewer manhole/cleanout 100'+ Holding tank N/A Manure/animal excreta sforege areas 100'+ SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundation 5'+ Properbj line 5'+ Water main N/A Water service line. 10'+ Wells on adjacent lots 100% Absorption field 5'+ Surface water 100'+ SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Properly line *2' Building foundation 10% Water service line 10% Surface water 100% Curtain drain NONE KNOWN Wells on adjacent lots. 100'+ Water main N/A Driveway, parking/vehicle storage 10'+ F. COMMENTS WR#970028 G. ENGINEER'S CERTIFICATION I certify that I have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA CO,SA guidelines in effect on this date. Engineer's Printed Name JEFFREY A. GARNESS Date t (-Z i J l~) (Rev. 11/05) /~f ~-_~ ~' -'-- ~ ~ -'~'""'-cSPRUCE- _STREET "~ :'...'."' . ~/ , ..' ~ <' .. ~' ~ ~'~ '~ ~ 65. :4' . . I ~2. Parcel I.D. CERTIFICATE FOR A 014-141-2 1. GENERAL INFORMATION Municipality of AnchoraGe Development Services Depsrtment Building Safety Division On-Site Water & Wastewater Program 4700 E!more Read P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsite (907) 343-7904 OF ON-SITE SYSTEHS SINGLE FAHILY APPROVAL DWELLING Expiration Date: -? ~ //~ '-// Complete legal description Location (site address) Current Property owner(s) Mailing address Lending agency Mailing address Real Estate Agent Mailing address FOREST VIEW HEIGHTS LOT 1 .3538 EAST 72ND *ANCHORAGE, AK 99507 MAYO WELLS 5338 EAST 72ND Day phone *ANCHORAGE, AK 99507 Day phone c/o AGENT KIMBERLY ANDERSON W/ DYNAMIC Day phone 5111 "C" STREET *ANCHORAGE, AK 9950,3 529-1151 Unless otherWise requested, COSA will be held by DSD for pickup. 2. NUMBER OF BEDROOMS: 6 3. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well · Individual On-site · Individual Water Storage [] Individual Holding tank [] Community Class__Well [] Community On-site [] Public Water System [] Public Sewer [] The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of On-Site Systems Approval (COSA) based only upon the representations given in paragraph 4 by an independent professional civil engineer registered in the State of Alaska. Certificates of On-Site Systems Approval are required for the transfer of title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or water supply system. DSD also issues COSAs upon request to homeowners. Certificates of On-Site Systems Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued with new water samples. (Certificates may be reissued for a period of up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. STATEMENT OF ~NSPECT!ON BY ENG!NEER As certified by. my seal affixed hereto and as of the validation date shown below, I ........ v~,,y L,,a,~ ..... ,, ~, investigation, based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines for this application, ~" ..... ~,5~t' ~ '~he o,,-s,..e- ;' water SUDD!V and/or wastewater H¢o~o,l ovef,~m ie ./~ ) safe, ~,,nctinna/ an~ adequate for the number of bedrooms and type of structure,,,,~¢.~,¢"¢;~f~ herein. I fu,ffher vefi~/ that based on the u noil~uOt~ o~u~eo ~,,, ~ M~,,,cwa,,y o~ ~,,~ho,~se and ~m my,,;""o~*~°*~",, ~.,s~.,~,, and inspection, ..*~. ~ on-site water supply and/or wastewater disposal system is(are) in compfiance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installaSon. Name of Firm GARNESS ENGINEERING GROUP, Ltd. Address 5701 E. TUDOR ROAD, SUITE 101 * 'ANCHORAGE, AK 99507 Engineer's Printed Name JEFFREY A. GARNESS, P.E. Phone Date 557-6t79 Engineer's Comments: In conducting this evaluation, GEG, LtD. attempted to provide a thorough, conscientious engineering analysis of the system in accordance with ADEC and MOA DSD Guidelines & Regulations. The reported results described the performance of the system under the conditions encountered at the time of the test, and separation distances measured to readily identifiable features. The operational life of all wells and septic systems depend on the local soils condition, groundwater levels that may fluctuate during the year, and the water usage of the family being served by the system. These conditions are outside the control of the evaluator of the system. Satisfactory test results do not guarantee future performance of the system, nor do they guarantee that there are no hidden defects or encroachments. GEG, LTD. can therefore not provide any warranty or future estimate of how long the system will continue to meet the operational requirements of the ADEC or MOA DSD. The content of this report is for the sole benefit of the owner listed above. Any reliance upon or use of this report by any other person or party is not authorized, nor will it confer any legal right whatsoever. DSD SIGNATURE / '\,,,~ Approved for (~ Disapproved. Conditional approval for bedrooms. bedrooms, with the following stipulations: ~,JS,~, uhec~tu~ Septic System Advisory Well Flow Adviso~ Nitrate Advisor), (Rev. 11105) Arsenic Advisory Maintenance Agreements Supplemental Engineer's Report Other Original Certificate Date:.~_ - / ~ ~//~ Municipality of Anchorage Development Services Department Building Safety Division On-Site Water & Wastewater Program 4700 Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsite (907) 343-7904 CERTIFICATE OF ON-SITE SYSTEMS Legal Description: FOREST VIEW HEIGHTS LOT 1 APPROVAL CHEGKLIST Parcel ID: 01 4-1 41 -,245¢ ~ ¢o WELL DATA Well type PRIVATE Date completed PRE Total depth *45+ ft. *INSPECTED BY APWS-SEE ATTACHED RECEIPT. If A, B, or C provide PWSID# N/A 1974 Sanitary seal (Y/N). YES Cased to *45+ ft. FROM WELL LOG NO WELL LOG Well Log (Y/N) NO Date of test Static water level Well production WATER SAMPLE RESULTS: Coliform 0 colonies/100 mi. Arsenic: ND ug./L. SEPTIC/HOLDING TANK DATA Wires properly protected (Y/N) YES g.p.m. Casing height (above ground) 12+ in. Foundation cleanout (Y/N) YES Date of pumping 3/31/11 ABSORPTION FIELD DATA Date installed 7/'16-17/'97 Length 67 .ft. Nitrate 0.252 mg./L. Date of sample: 5/50/11 Tank Type/Material SEPTIC/STEEL Tank size 2000 gal. Number of Compartments 2 Depression over tank (Y/N) NO Pumper I'BELOW EXISTING GRADEI Soil rating (g.p.d./ft2o~ 1.2 Width 5 ft. AT INSPECTION 3/3o/11 45 Date installed 7/16-17/97 Cleanouts (Y/N) YES High water alarm (Y/N) YES MCDONALD'S PUMPING Total depth '11.96 ft. Eft. absorption area 670 ft2 Monitoring tube YES Date of adequacy test *'3/31/11 Results (Pass/Fail) PASS Fluid depth in absorption field before test DRY in. Water added 2560ga1. Elapsed Time: 418 min. Final fluid depth DRY in. Absorption rate >= Any rejuvenation treatment (past 12 mo.) (Y/N & type) NONE KNOWN **PRE-SOAK ON 3/30/11 WITH 2080 GALLONS OF Depression over field NO For 6 bedrooms New depth 14.5 in. 9OO+ g.p.d. If yes, give date - WATER. System type TRENCH Gravel below pipe 4.2 Collected by: GEG, Ltd. 8.73 g.p.m. D. LIFT STATION Date installed "Pump on" level at__ Size in gallons Manhole/Access ~ ~ in. "Pump off" levef_~t~. High water alarm level at in. E. SEPARATION DISTANCES Cycles tested. Meets alarm & circuit requirements~ SEPARATION DISTANCES FROM WELL ON LOT TO: Septic tank/lift station on lot Absorption field on lot 100'+ Public sewer main 75'+ Sewer/septic service line 25'+ Animal containment areas. 50% 100'+ On adjacent lots 100'+ On adjacent lots 100'+ Public sewer manhole/cleanout Holding tank N/A Manure/animal excrete storage areas 100'+ 100'+ SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundation 5'+ Property line. 5'+ Water main N/A Water service line 10'+ Wells on adjacent lots 100'+ Absorption field Surface water 5'+ 100'+ SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line *2'+ Bud ng foundat on. 10'+ Water service line 10'+ Surface water 100'+ Curtain drain NONE KNOWN Wells on adjacent lots 100'+ Water main N/A Driveway, parking/vehicle storage 10'+ F. COMMENTS WR#970028 G. ENGINEER'S CERTIFICATION ! certify that I have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this date, Engineer's Prinlted r~ame JEFFREY A. GARNESS Date COSA Fee $ Date of Payment Receipt Number (Rev. 11/05) Waiver Fee $ Date of Payment Receipt Number Aa ow Pump & Well S svice, LLC P.O. Box 110496 Anchorage, AK 99511 CUSTOMER JOB SiTE - - -- '-- t(_,)i"'j ~ V'~. QUANTITY DESCRIPTION PRICE AMOUNT .h-' ~* r-- / / . . --f ..... ,'- ' ,. -, ~ ., . l, .,n, ,~ C r LABOR HOURS RATE AMOUNT TOTAL MATERIAL TOTAL LABOR !WORK ORDERED BYI DATE COMP. ' ...... ; ! LABOR " I '~' T,,h~nk S G, MI-U, ,~_ (i Hereby Acknowledge the Satisfactory Completion of the Above Described Work and agree that if above work is not paid for in 90 days I agree to allow Aarow Pump~. We[! Se:n,iCe:. ..... , .........:: n the right to remove unpaid ~,.r .... ~t~'1~','~'~l~m4~ll''"l'~'' _~nd, charge for labor already pedormed _,~, labor to remove unpaid for equipment.) TERMS: ACCOUNTS PAYABLE AT 10TH OF MONTH FOLLOWING PURCHASE. SERVICE CHARGE AT RATE OF 1.5% PER MONTH WILL BE CHARGED ON OVERDUE ACCOUNTS. East 72nd AVENUE Lot 20 / Lot 1~ Lot 18 Lot 17 USE EASEMENT GRANTED .,~ORIL 30, 2008 USE EASEMENT J GRANTED OCTOBER 7, '-"::'~J' ':'/:::'~' "".' ~:.~:. :.-:-.'~' '-"':'~ ~:~ - ~ I ' . . .~. ': .~ --" .... ... - ~.. ~ ..-: .:'.. :; :.-,: :---,..: :Lot ~'-t.:'"'--.'-/-X ..... .' -.: --.-, ....~,7~s ,.f..~.-. ~'.'.'+..,1 m-:':'..~ ~:~-~-...-::-.-..: .--:.. '::~...X : ".~.. %. ~6 . -= . ' -~ ~'E' ';- ' :-+ 12.g '' '- .. ........ "--' ~w~ ~.-.. : ~*' ~3~.58' ,~ "'"~ .... ." '1 : ~ ~ '~.. -"" o ': '~V xL Lot 2 ~.. ~. r I s 89'58'30"E 133.58' / ~1 ~ 80'58'30~ 133.58' I J ~uw ~m~ Lot 4 J = 33.00' _ J I I -] I I I , / / / / / PLOT PLAN AS BUILT X SCALE 1" = 30' GRID SW 2134 Project No. 11-035 La n g (907) 522-6476 Registered Land Surveyors (907) 522-4625 ken~langsurvey.com / Jonafhan~langsurvey. com & Associates, inc. 115oo Oaryl Avenue, Anchorage, Alaska 99515-3049 Phone Fax I hereby certify that I have surveyed the fallowing described properly: LOTS 1, 2 & 3, FOREST VIEW HEIGHTS SUB, (Plat 63-44) Anchoroge Recording District, Alaska, and fhaf the Improvements slfuafed thereon are wlfhln the properly lines and do not encroach onto the properly adjacent thereto, fhaf no Improvements on the properly lylng adjacent thereto encroach on the surveyed premises and fhaf there are no roadways, fronsmlssion lines or other visible easements on said property except as indlcafed hereon. Datsd this the ~Z+h Day of ~,~., , '~t.\ , af Anchorage, Alaeka It Is the responelbillly of the owner fo determine the existence of any easements, covenants, or restrictions whlch do not appear on the recorded subdivision plat.