Loading...
HomeMy WebLinkAboutTHOMAS L BOYLE BLK 2 LT 11BThomas L Boyl Block 2 Lot lIB #015- 283-17 Municipality of Anchorage On-Site Water and Wastewater Section - (907) 343-7904 Page 1 of 2 ON-SITE WASTEWATER INSPECTION REPORT Permit Number: OSP201477 PID Number: 015-283-17 Dwelling: M Single Family (SF) El with ADU E] Duplex (D) El Two Single Family Project: M New E] Upgrade Name MCAPLIN ABSORPTION FIELD n Deep Trench FMI Wide Trench 0 Bed M Mound Site Address 12241 GANDER ST, ANCH AK El Other Phone Number of Bedrooms Soil Rating I Total depth from original grade 77 4 7 0.8 GPD/SF J 5 Ft. LEGAL DESCRIPTION Depth to pipe invert from original grade 2 Ft. Gravel depth beneath pipe 3 Ft. Subdivision Block Lot THOMAS BOYLES BLK 2, LOT 11 B Fill added above original grade 1.0 Ft, Gravel length 87 Ft. Township Range Section Gravel width 5.0 Ft. Beds: Number of Lines Distance between lines Ft. SEPARATION DISTANCES To septic Absorption � Lift Station Holding Sewer Total absorption area Number of trenches Dist. between trenches From Tank Field Tank Line 750 Ft? 1 Ft. Well I 100+1 100,+ 50'+ TANK Septic E S.T.E.P. [I Holding [I Other El Manufacturer Capacity ANCH TANK 1500 Gal. Surface Water 1001+ 100'+ Material PLASTIC 12 Number of compartments Lot Line 10'+ 10'+ NA Foundation 10'+ 101+ LIFT STATION Manufacturer ANCH TANK Capacity 1500 Gal. Remarks Alarm location Electrical installed by EAST WALL/ CRAWLSPACE RISING SUN PIPE MATERIAL House to tank 3034 drainfield Tankto 3034 Installer MIKE N ANDERSON, P.E. Drainfield 3034 CO/MT 3034 inspector MIKE N ANDERSON, P.E. BENCH MARK (Assumed elevation) 101 ft Inspection 10 1/23/21 nd 1/24/21 2 Location and description dates: TOP OF TANK MH 3rd 4m ON-SITE WATER AND WASTEWATER SECTION APPROVAL Conditional Approval: Date A ........ ........ C E - 944,-) -Z Septic System Approved Date JrJ[202z_ io kk "DIESSiO Note: this approval does not include well permit requirements. (Rev 05/02/18) Permit No. OSP201477 Page 2 of 2 Municipality of Anchorage DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 Anchorage, Alaska 99519-6650 Telephone: 343-4744 On—Site Wastewater Disposal System and/or Well Inspection Report Legal Description: THOMAS L BOYLE BLK 2 LT 11B PID No.: 015-283-17 M RK A B / C01 45 28 TC01 46 30 \ TCO2 47 31 MT1 45 85 MT2 93 50 • I BENCH, Tb� OF MH DUE TO WIP TER CONDITIONS 100' WELL RADIUS MT INSTALLED OF TRENCH 3 FROM END— TYP. A / _ \ H2 MT i / \ HOUSE M C01 0 — I� I/ II CO�- I I I I \ \ I IIS I Lj I / ASBUILT / SCALE: 1"=50' C01 TC01 TCO2 / 0 ��•� �: MT1 MT2 1 OG 1 1 1 1 1 1 f (�•♦.. .�♦���.� �.�• ••� � . -2.0 FILL / 49 T" FILTER FABRIC & INSULA110N �•��� / ,GALLON 1'500 PLASTICTIC STEP TANK �� 'MICHAEL N. ANDERSON Aff 9 95 90 AV No. CE 9469 5-22-22 AV SEPTIC SECTION TH#2 WATER ® 88 OCT 2019 ♦♦,,/�jyT\.�♦ N.T.S. >3 L Lvi fl i — CZ M 2- 3- 4- 5- C? M 6- 7- 8 - 11 (' ofrig..^ 20 - COMMENTS WAS GROUND WATER ENCOUNTERED? IF YES, AT WHAT DEPTH? Depth to Water After Monftoring? Date: Site Plan Reading 1r4�.�.�. �w P•T � Municipality of Anchorage Net Time Development Services Departmentit Net Drop On -Site Water and Wastewater Section *; 49TH 4700 Elmore SL P.O. Box 196650 Anchorage, AK 99519-6650 •• • •••••••••• ;. www.muni.org/onsite (907) 343-7904 • MICHAEL N. AKDLkSCN .•. a i CE - 9469 Soils Log - Percolation Test \ a� Performed For: M C `pl n Date Performed: Legal Description: T-"Uyy At 04 t -r �i Township, Range, Section: >3 L Lvi fl i — CZ M 2- 3- 4- 5- C? M 6- 7- 8 - 11 (' ofrig..^ 20 - COMMENTS WAS GROUND WATER ENCOUNTERED? IF YES, AT WHAT DEPTH? Depth to Water After Monftoring? Date: Site Plan Reading Date Gross Time Net Time Depth to Water Net Drop ki L t 'rrr,,, • `f` Z, 5 A LIE n 2 PERCOLATION RATE _( 7—, (minutes .h) PERC HOLE DIAMETER 't TEST RUN BETWEEN _:1 FT AND FT PERFORMED BY: " t'qA' I CERTIFY THAT THIS TEST WA PERFORMED IN ACCORDANCE WITH ALLSTATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: Rlijq I gi "� Development Services Department 04 Ali Phone: • i On -Site i,Section;:907 t • • Permit Number: # osp201477 Date of Issue: 1/20/21 Parcel Identification Number: Date Started: 3/16/21 Date Completed: 3/16/21 Is well located at approved permit location? Yes ❑ No ❑ Legal Description: Thomas L Boyle b1k2 lot11 B G:2734 Property Owner Name & Address: McAlpin Shawn & Joell 12241 Gander St. Anchorage, AK Borehole Data: Depth (ft) Soil Type, Thickness & Water Strata From To Stick up 0 2 Overburden 2 4 Silt & gravel 4 10 Silty sand & gravel 10 15 Moist silty sand 15 25 Dry silt & gravel 25 60 Wet silt & gravel 60 74 Gravel w/ H2O 74 77 Water Sample Results: Arsenic: I'Q'D ug/L Nitrates: 6.5 mg/L Total Coliform Bacteria: �-- colonies/100mL q/jgj22 Method of Drilling ❑ air rotary ❑ cable tool Casing type: steel Wall Thickness: 250 inches Diameter:6 inches Depth: 77 feet Liner Type: Diameter: inches Depth: feet Casing stickup above ground: 2 feet Static water level (from ground level): 10 feet Pumping level: feet after hours pumping _gpm Recovery Rate: 11.5 gpm Method of Testing: airlift Well Intake Opening Type: (� Open End ❑ Open Hole ❑ Screened Start feet Stopped feet ❑ Perforations Start feet Stopped feet 20' Start 0 feet Stopped 20' O Well Disinfected Upon Completion? Yes No II Method of Disinfection: tabs Comments: M ❑ Well Driller: Johnny Kay Company: Hefty Drilling, Inc. Mailing Address: PO Box 112130 Anchorage, AK 99511 Attention: The well driller shall provide a well log to the On-site Water and Wastewater Section within 30 days of completion. Development Services Department Building Safety Division 5kvF On -Site Water & Wastewater Program ow' 4700 Elmore Road z z P.O. Box 196650 MarkBegieh Anchorage, AK 99507 Mayor www.muni.org/onsite (907) 343-7904 Pump Installation Log Well Drilling Permit Number: ? 0 / H % 7 Date of Issue: l' )U- ?1 Parcel Identification Number: Legal Description L l�,ylc Pump Installation Date: ' � 2 L+ OF 2-73 q Pump Intake Depth Below Top of Well Casing: 70 feet Pump Manufacturer's Name: (jr'VMd �j 5 Pump Model: 5 ! GSL'- v7 —.2 3o Pump Size �� hp Pitless Adapter Burial Depth: /0 feet Pitless Adapter Manufacturer's Name: Com. l Pitless Adapter Installer: �lnS�"� `ate. Well Disinfected Upon Completion? 0 Yes ❑ No Method of Disinfection: <T e, b5 I Comments: Pump Installer Name: Johnny Kay Hefty Drilling, Inc. Property Owner Name & Address: /" cAl ptin 4-- 3kl i Attention: The pump installer shall provide a pump installation log to the DSD within 30 days of pump installation. CO 49 R `9 h'Ae�— s SHANE A. HOLT �� G LS -6914 y��4� ,\,°fessiona� �-Qo 0 0 0 0 0 s EAST 300.00 NOTE. NO EASEMENTS APPEAR ON THERE CORD PLAT THESURVEYDATA AND MEASUREMENTS HEREONAREPREPARED FOR THE OWNER OFRECORD AS OF THEDATE OF THIS SURVEY. ANY USEOF THIS DRAWING BY THIRD PARTIES IS PROHIBITED UNLESS WRITTEN PERMISSION IS PROV/DED. THE INFORMATION HEREON IS FOR THE USE OF LENDING INSTITUTIONS SPECIFICALLY TO SHOD/ ANY CONFLICTS BETNEEN EXISTING STRUCTURES AND PLATTED LOT LINES ANDIOR EASEMENTS; AND IS NOT TO SE USED FOR POSITIONING ADDITIONAL STRUCTURES, IMPROVEMENTS, OR FENCELINES- EASEMENTS OF RECORD, OTHER THAN THOSE APPEARING ON THE RECORD PLAT , ARE NOT SHOUN HEREON ( UNLESS INDICATED) NOTE: FENCELINES THAT MAY APPEAR ON THIS PRAYING ARE NOT TO BE USED TO DETERMNE PROPERTY LINES OR POSITION ADDITIONAL IMPROVEMENTS. ANY PAVING SHONN HEREON MAY BE APPROXIMATE DUE TO EXCESSIVE SNON ANDAOR ICE. "FINAL S TRUC TURE A S BUIL T" AS-BUILTSURVEY i" =301 /HEREBY CERTIFY THA T / HA VE PERFORMED A SURVEY OF THE FOLLOWING DESCRIBED PROPERTY LOT11 3BLOCK2 THOMAS L. BOYLESUB. (PLATP-244B) ANCHORAGE RECORDING DISTRICT, ALASKA, AND THAT THE VISIBLEIMPROVEMENIS SITUATED THEREON ARE WITHIN THE PROPERTYLINES AND NO VISIBLE ENCROACHMENTS EXIST OTHER THAN NOTED. DATED ATANCHORAGE,ALASKA THIS 12TH DAYOF APRIL , 2022 15409 F3221-50 HOLT LAND SURVEYING 9309 GROVER DRIVE ANCHORAGE,AK 99507 223-8615 MUNICIPALITY OF ANCHORAGE On -Site Water & Wastewater Program PO Box 196650 4700 Elmore Road Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997 http://www.muni.org/onsite On -Site Water & Wastewater System Permit Permit Number: OSP201477 Work Type: WellSeptic Initial Tax Code Number: 01528317000 Site Legal Address: THOMAS L BOYLE BLK 2 LT 11 B G:2734 Site Mailing Address: 12241 GANDER ST, Anchorage Owner: MCALPIN SHAWN & JOELL Design Engineer: ANDERSON CONSTRUCTION & ENGINEERING This permit is for the construction of: Q Disposal Field Q Septic Tank ❑ Holding Tank ❑ Privy Effective Date Expiration Date Lot Size in Sq Ft: Total Bedrooms: i Department 1/20/2021 1/20/2022 49500 Q Private Well ❑ Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing 4 Special Provisions: 1. An additional test hole is required to be done prior to the construction of the septic field. Construction may proceed at your own risk before the 7 day water monitoring is complete. Please submit stamped and signed results with the As -built Inspection Report. If the results require a design change, construction of the system will stop pending On -Site review and approval. 2. Existing monitoring wells/groundwater monitoring tubes are to be removed. C0# 1 90 Cho'nc,eA -Fo Received By: Date: Issued By: Date: 120 MUNICIPALITY OF ANCHORAGE • �.� �.���,� as�,�..�r x .,,�„N..-„��: .., , s•.�,.�:� Development Services Department Phone: 907-343-7904 On -Site Water & Wastewater Section Fax: 907-343-7997 ON-SITE SEPTIC/WELL PERMIT APPLICATION Parcel I.D. 015-283-17 Property owner(s) SHAWN & JOELL MCALPIN Day phone 7 a 0 - fl Mailing address 7727 LUMBIS AVE, ANCH AK 99518 Site address 12241 GANDER ST, ANCH AK Legal description (Sub'd., Block & Lot) THOMAS L B4OYLE BLK 2 LT 11 B Legal description (Township, Range & Section) Lot Size 49500 Sq. Ft. Number of Bedrooms 4 APPLICATION IS FOR: (® all that apply) Absorption Field Fx� Septic Tank E Holding Tank ❑ Privy ❑ Private Well E Water Storage ❑ APPLICATION IS AN: TYPE OF DWELLING: Initial 0 Single Family (SF) El (w/wo ADU) Upgrade ❑ Duplex (D) ❑ Renewal ❑ Multiple Dwellings ❑ (SF and/or D) THIS APPLICATION INCLUDES A WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit/Rush Fees: 5 co Date of Payment: 17 C C Receipt Number: 3 `{ Permit No. 05 ea OILI 99 Waiver Fees: Date of Payment: Receipt Number: Waiver No. G:\Development Services\Building Safety\On Site Water and Wastewater\Forms\Client Forms\Permit Application.doc Jan. 16, 2021 Municipalities of Anchorage Departments of Health and Human Services P.O. Box 196650 Anchorage, Alaska 99519-6650 Fax 249-7847 Re: New septic & well permit Legal: THOMAS L BOYLE BLK 2 LT 11B To Whom it may concern: This is a request for a septic and well permit on the above referenced lot. A single test hole was excavated and found silty sand (SM) fill in the top two feet then it changed to the natural silty gravel (GM) below to the bottom of the hole. Water was found at 14 feet during the excavation and after the 7 day monitoring period. On Nov. 17, 2020 the water level was again checked and found it dry. Other monitoring tubes were found on the site (see site plan) and they were all dry as of Nov. 17, 2020. Due to environmental cleanup done on lot 10 monitoring wells were installed around the perimeter of the site for future testing. The lot slopes to east at 5:1 (20%) due to the added fill which was installed in the past 20 years. All of the leach field will be located in the natural material not the fill. The old permit done by Pannone Engineering was never built and will not be used for the new system. Also the Class C well shown on the Pannone drawing appears to be a monitoring well only. This permit will not impact any of the neighbors or encroach on any wells, septic or open water issues. Sincerely Michael N. Anderson, P.E. 4661 Natrona Anch, Ak 99516 Ph 727-8864 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP201477, Deb Wockenfuss, 01/20/21 DESIGN CRITERIA: 4 BDRM X 150 = 600 GPD SOILS = 600/0.8 = 750 SQ FT REQ'D 750/5 *(0.58) = 87', USE 87' (1) TRENCH 5' DEEP 3.0' EFFECTIVE 5.0' WIDE 87' LONG SEPTIC FIELD SECTION I MOUND OVER (TH#1) o � —GRADE WI FILL, SM FILTER FABRIC Z. -2.0) & INSULATION PROPERTY LINE PIPE _ 314"O 5.0' SEWER ROCK GM �f�r ' MO 5.0' SEPTIC FIELD SECTION Septic Design Prepared for SHAWN & JOELL MCALPIN THOMAS L BOYLE, BLOCK 2, LOT 11 B Anchorage, Alaska Michael N. Anderson, P.E. DATE: 4601 NATRONA AVE DRAWN: ANCHORAGE, ALASKA 99516 (907) 345-3377 / FAX: (907) 345-1391 SCALE: -HUFFMAN ROAD - • .... .......... 'ff,qs•••, AV • 49 TH i, ..... .° 11/4/2021 ��� MICHAEL N. ANDERSON; No. CE 946 DJR .9 •�� �j♦ ,11-5-21 1"=200' ••�SS�.. 44TAVA%������ I W WI PROPERTY LINE _ il'� PROPOSED �. DRAINAGE FIELD PROPOSED HOUSE PROPOSED WIELL 100' RADIUS Septic Design Prepared for SHAWN & JOELL MCALPIN THOMAS L BOYLE, BLOCK 2, LOT 11 B Anchorage, Alaska Michael N. Anderson, P.E. DATE: 4601 NATRONA AVE DRAWN: ANCHORAGE, ALASKA 99516 (907) 345-3377 / FAX: (907) 345-1391 SCALE: -HUFFMAN ROAD - • .... .......... 'ff,qs•••, AV • 49 TH i, ..... .° 11/4/2021 ��� MICHAEL N. ANDERSON; No. CE 946 DJR .9 •�� �j♦ ,11-5-21 1"=200' ••�SS�.. 44TAVA%������ I VACANT PREVIOUS TH BY THOMAS L \� OTHERS, DEPTH 8', i BLOCK 2, LOTYLE �--- --� �� DRY NOV. 18, 2020 �� ANEWPROPERTY LINE \ / TEST HOLE 1 iw i w PRIOR TO • I INSTALLATION \ Lu PROPOSED 1,250 Z GALLON PLASTIC WELL SEPTIC TANK W/ 20" ® RISER. MAINTAIN 10' 1 FROM DECK I I / 5:1 SLOPE TYP. —� ` � 1 CLASS FOR CHUCH AWAY A WELL > 200' � / r�CO rI I PROVOSED O (TCO 1 1 • I I I (SEPTIC 1 �\ HpUSE TO�— I DC II \)e ` \� j j I ``� i /H#1 5:1 SLOPE TYP. I i i• �\��`NP� ���/ i i I `__------"" /�PROPOSEDWELL ��� IMT,�i' THOMAS L BOYLE 100' RADIUS L i�0 L J BLOCK 2, LOT 11B per THOMAS L BOYLE BLOCK 2, LOT 12B_ I T THOMAS L BOYLE EXISTING BLOCK 2, LOT 10 MONITORING WELL INSTALL BY I PREVIOUS OWNER DUETO VACANT CONTAMINATED NO WATER WELL LOCATED ON THIS SOILS ON LOT 10, VACANT LOT. CONTAMINATED SOIL DEPTH 10' DRY NOV. MONITORING WELLS NOT SHOWN 18, 2020 I I �0T 10 Septic Design Prepared for SHAWN & JOELL MCALPIN ��.P��,OF q�late��� ..�''•?'♦♦♦ THOMAS L BOYLE, BLOCK 2 LOT 11B :•�••••••• `'• Anchorage, Alaska49 TH='♦♦♦ �.. .MI ' E!��;- ;MICHAEL N. ANDERSON; Michael N. Anderson P.E. / DATE: 11/4/2021♦ 4601 NATRONA AVE DRAWN: DJR••.11-5-21 , 'Iff ♦ No. CE 9469 • AV ♦♦1♦� ANCHORAGE, ALASKA 99516 ••.••AV �D'.'''...............�c:�i (907) 345-3377 / FAX: (907) 345-1391 SCALE: 1 "=50' �14.� Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP201477, Deb Wockenfuss, 01/20/21 On-Site Water & Wastewater System Permit  MUNICIPALITY OF ANCHORAGE Development Services Department On-Site Water & Wastewater Program 4700 Elmore Road, PO Box 196650 Anchorage, AK 99519-6650 Telephone: (907) 343-7904 Permit Number: OSP111334 Tax Code Number: 01528317000 Work Type: WellSeptic Initial Permit Effective Dates: March 28, 2013 to March 28, 2014 Design Engineer: PANNONE ENGINEERING SERVICE Subdivision: THOMAS L BOYLE Site Legal Address: THOMAS L BOYLE BLK 2 LT 11B G:2734 Owner/Address: MCCAULEY JAMES L 12241 GANDER ST ANCHORAGE AK 995160000 Site Mailing Address: 12241 Gander ST, Anchorage Lot Size in Sq Ft: 49500 Total Bedrooms: 4 This permit is for the construction of: Y Disposal Field Y Septic Tank N Holding Tank N Privy Y Private Well N Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80). 3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours). 4. From October 15 to April 15, a subsur[ace soil absorption system under construction during freezing weather must either: A. Open and Close on the same day. B. Covered, sealed, and heated to prevent freezing. Received B~ Date: MUNICIPALITY OF ANCHORAGE Community Development Department Development Services Division On-Site Water & Wastewater Program Phone: 907-343-7904 Fax: 907-343-7997 Mayor Dan Sullivan ON-SITE SEWER/WELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Parcel I.D. 01~"-- '?--~'.~- I'7 Property owner(s) "5'~,t¢,~ /.. /14~.~,~¢/.E'¥ Day phone Mailing address 1'7.-"¢~l O.-,~,,Vl¢~'.~ 6'r'~u-~-7-., ~/dcjr)o~/,.c~' l~J~' Site address Legal description (Sub'd., Block & Lot) "1"~1~0,~-~, Z.. ~:)'t~Z.~~- Legal description (Township, Range & Section) Lot Size 4../q., COO Sq. Ft. Number of Bedrooms THIS APPLICATION IS FOR: (F~] all that apply) Absorption Field Septic Tank Holding Tank Privy Private Well Water Storage THIS APPLICATION IS AN: Initial [~ Upgrade [] Renewal [] THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR: I certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal Codes. (Signatu~ of'~r'o~p'e~y oCner or authorized agent) Permit/Rush Fees: Date of Payment: Receipt Number: Permit No. Waiver Fees: Date of Payment: Receipt Number: Waiver No. G:\Building\On Site\Forms\Client Forms\Permit App_010411.doc (Rev. 1/11) Pannone Engineering Services LLC Steven R. Pannone, Principal Registered Professional Engineer E-mail: steve@panenRak.com November 3,2011 Municipality of Anchorage Development Services Department On-Site Water & Wastewater Program 4700 S. Bragaw Street P. O. Box 196650 Anchorage, Alaska 99519 Subject: Thomas L Boyle, Block 2, Lot llB Septic System Permit Upgrade Request Ladies and Gentlemen: I am writing to request a permit to construct a new septic system and well be issued for this property. The proposed system will serve a proposed four-bedroom house. Currently the lot is undeveloped. A new drain field will be installed in northeast portion of the lot and will be sized to handle a four-bedroom waste stream. The reserve area will be parallel and just south of the proposed field. The surrounding developed lots are served by private wells. The lot to the south is served by a class 'C' well and is located more than 150 feet from the proposed soil absorption system. The remaining wells are located over 100 feet from the proposed soil absorption system. 1. Soils. One test hole was excavated by Parmone Engineering Service in November of 2011. See the soil log attached. Ground water was monitored for seven days. No ground water was monitored to a depth of ten feet (10') below ground level after the monitoring period. Bedrock was not encountered in the test hole. It is my opinion, based on the results of the percolation tests and overall soils appearance; an application rate of 4 gallons/day/square feet should be used, using an advanced wastewater treatment system. Soil Absorption System Design. a. See Sheet 2 of the design package 3. Surface Water: There is no surface water within 100 feet of the proposed septic tank and the existing drain field. The proposed drain field upgrade will maintain at least 100 feet from all surface water mad drainage ditches. 4. Topography: The average topography in the area of the proposed septic system is approximately 5 percent. There are no steep slopes within the vicinity of the proposed drain field based on the survey hfformation. Mailing: P.O. Box 100217, Anchorage, AK 99510-0217 Physical: 615 East 82r'd Ave, Cuite B6, Anchorage, AK 99503 Telephone: (907) 272-8218 FAX: {907) 272-8211 Page 2 of 2 5. Drawing Markings: The Drawings are marked "For MoA Review Only". When written notification that the review is complete and that there are no further comments is received from MoA On-Site Department, the note will be removed and "Issued for Construction" drawings will be issued. The proposed installation will not affect the future development of the surrounding or existing lots. There are no wells within 100 feet of the proposed septic location. If you have any questions or concerns, please contact me at 272-8218. Sincerely, Ow~ffdivi] Attachments: Mailing: P.O. Box i002t7, Anchorage, AK 99510--0217 Physicah 615 East 82~* A~,e, Suite B6, Anchorage, AK 99503 Telephone: (907) 272-8218 FAX: (907) 272-8211 LOT UNDEVELOPED / -/ i NO WELLS OR SEPTICS / PRIMARY DRAIN FIELD (P) / 8,w x 80LF x 0.~' ED., W/ 11. S~O, ~' TO ~ ,,' RESERVE DR~,~iN FIELD (P) 5 " 5'W X 50LF X 0.5' ED., W/ 1' SAND, 5' TD '-~ ~ 3.~ z W 1500g S.T.E.P. TANK ~ ~w~ ~ ~ ~/~x~o ~o~ ; ........ / C~SS 'C' WELL FOR CONSTRUCTION P.O. BOX 100217 ANCHORAGE, AK 99510 ~ ..... ]~O~ja 11/16/11 P~O~[ (007) 272-8218 [~X (~07) 272-8211 ~~.'~i JAMES MCCAULEY ~- CE 8149 '~ 'ERMIT NO. 12241 GANDER STREET ,~,~.. ~ 0SPl11334 PLAN ANCHORAGE, AK 99516 ....... " 1 OF4 SPECIAL PROVISIONS TO SPECIFICATIONS 1. ALL CONSTRUCTION SHALL BE INSTALLED AS SPECIFIED IN THE MOST CURRENT EDITION OF THE MUNICIPALITY OF ANCHORAGE STANDARD SPECIFICATIONS (MASS) FOR COMPONENT PARTS AND MATERIALS USED IN CONSTRUCTION OF ON-SITE WASTEWATER DISPOSAL SYSTEMS. 2. ALL WORK SHALL BE IN ACCORDANCE WITH THE ATTAOHED SPECIFICATIONS. 3. SCOPE OF WORK: INSTALL NEW 150D GALLON S.T.E.P. TANK W/AX2D POD AND NEW SOIL ABSORPTION SYSTEM. 4. GROUNDWATER WAS NOT OBSERVED TO A DEPTH OF 1D FEET BELOW EXISTING GRADE DURING EXCAVATION OF THE SOIL TEST HOLE. IF AN APPARENT WATER TABLE IS OBSERVED IN ANY OF THE EXCAVATIONS LESS THAN 10 FEET BELOW EXISTING GRADE NOTIFY THE ENGINEER IMMEDIATELY. //~/_FILTER FABRIC 4" DRAIN PIPE TH-1 DRAIN ROCK ///1 -0.5 ~ -5.0 -- SM B.O -9.0 ~ MONITORED z o 0 /// ~ ~IN NEW 1500 g ~ S.T.E.P. TANK " ' LW/~2o POD SEE SECTION AND PA~METERS ~1' BARD PROFILE DESIGN PArAMETErS PRIMARY/RESERVE SEPTIC SYSTEM ABBREVIATIONS NO. BEDROOM: 4 (600 gpd) TANK SIZE: 1500g S.T.E.P. CU COPPER W/AX20 POD DIP DUCTILE IRON PIPE SOIL RATING: 4 GPD/SF TH TEST HOLE AR~ RQD: 150 SF FC FOUNDATION CLEAN OUT SYS. ~PE: 5' WIDE TRENCH 0.5' E.D. T~ TANK CLEAN OUT NO. LEGEND MIN LENGTH: ~0 LF C~ CLaN OUT NO. M~ MONITOR TUBE NO. --W- WATER LINE/ USE: R.I. RIGID INSU~TION WELL RADIUS 50 LF X 5' WIDE, 0.5' E.D., DCO DOUBLE CLEAN OUT WITH 1' SAND, 5' TD DV DIVERTER VALVE -- SS i NEW SEPTIC TOTAL AREA: 250 SF FS FLOW SPLICER NOTES: ~0~ FOR CONSTRUCTION P.O. BOX 100217 ANCHORAGE, AK 99510 ~ ...... ;~2~z So~Iell/16/H · :~.~ ~.~.~. JAMES MCCAULEY ~. CE ~1~9 .~ PERMIT NO. 12241 GANDER STREET ~ ~.. .;~ osPm}~ DESIGN DETAILS ANCHORAGE, AK 99516 ~ii~0E~O~:c~ '. ...... '~ sh~t SOILS LOG - PERCOLATION TEST TEST HOLE 1 OR ORGANICS/ SLOPE ~-' SITE PLAN I -- SM SANDY SILT / × 2 ML GRAY SILTS ]~!~ . ~-'-. 7 -- SM SAND W1TH SOME SILT X BOH ~ M HOUSE 13 WAS GROUND WATER SLOPE .14 ENCOUNTERED? N '15 IF YES, AT WHAT TH DEPTH? -0-' X ~----'-'~ DEPTH TO WATER AFTER MONITORING? -0'- 18 DATE: 10/21/11 i 10/14/11 12:12 -- 4,00 -- 2 12:22 10 MIN 8.21 4.21 3 12:22 -~ 4.10 --- 4 12:32 10 MIN 6.50 2.40 5 12:32 --- 4.00 -- 6 12:42 10 MIN 6.46 2.46 PEROLATiON RATE 4.1 (min/inch) PERC HOLE DIAMETER 6 inches TEST RUN BETWEEN 5 FTAND 6 FT COMMENTS: Test hole excavated by A+ HOME SERVICES. Prec hole was presoaked. Test run for one hour. Last 3 readings reported PERFORMED BY: Steven R. Pannone~ P.E. I CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDLINES IN EFFECT ON THE DATE OF THIS TEST. FO~ CONSTRUCTION P.O. B0X 102954 ANCHORAGE, AK 99510 PHONE (907) 272-8218 FAX (907)272-8211 ~.~,,.,~..'.."' ..~,~.'?.~ Sca,e ~' ~r ."49 ~". 1¥ I NTS !P.I.D. THOMAS L BOYLE, BLOCK 2, LOT 11B .., -015-283-17 I Steven R. PonnoRe ~'~ PERMIT NO. JAMESGANDERMCCAULEYsTREET I~ ,~,...~. CE 8149...~.~.~,..~ 0SPlll 5.34 1224-1 ~ " " Sheet SOILS LOG ANCHORAGE, AK 99516 ~~ 3or4 WATER READING DATE CLOCK NET TIME LEVEL NET DROP TIME READING I 10/14/11 12:12 -- 4,00 -- 2 12:22 10 MIN 8.21 4.21 3 12:22 -~ 4.10 ... 4 12:32 10 MIN 6.50 2.40 5 12:32 ... 4.00 -- 6 12:42 10 MIN 6.46 2.46 ADVANTEX SYSTEM DESIGN ADVANTEX 24" 4" JIM CAP..,~~X20 POD~ INSULATED AUXILIARY PASSIVEAiR · RISER, PUMP,, VENT...~ I ANCHORAGE OF 6" PIPE OVER THIS CONNECTION TO PROVIDE J SHEER PROTECTION- 14' EXTEND TO BRIDGE EXCAVATION NO*ES: PANNONE ENO 8VC, LLC POR OONSTRUCT, ON p.o. 80X ~002'7 A"C"O"*OE, *K 99S'0~:,... ~_,,_.~--""~'"'"'""'.~'~, PHONE (907) 272-8218 FAX (907) 272-8211 ,..~..' .~..,../ ~ ,stole P.I.D. NO THOMAS L BOYLE, BLOCK 2, LOT 119 % -015-285-17 ~teven R. Ponno~e ~ ¢ PERMIT NO. JAMES MCCAULEY ~¢~. CE 8149 .'.~-~.. 0SPl11334 DESIGN DETAILS ANCHORAGE, AK 99516 ~*~'~';-'"' Sheet MUNICIPALITY C -F ANCHORAGE �VSN Development Services Department j Phone: 907-343-7904 On -Site Water & Wastewater Section Fax: 907-343-7997 Parcel I.D. 015-283-17 Certificate of On -Site Systems Approval Expiration Date: QJJA�0a 1. GENERAL INFORMATION Complete legal description THOMAS L BOYLE BLK 2 LT 11 B Location (site address) 12241 GANDER ST, AN C H AK Current property owner(s) Mailing address Real estate agent SHAWN & JOELL MCALPiN Day phone SAME - Day phone 2. TYPE OF DWELLING: Fx� Single Family (w/wo ADU) ❑ Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) 3. NUMBER OF BEDROOMS: 4 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Private Well F1 Private Septic 0 Water Storage ❑ Holding Tank ❑ Community Well ❑ Community ❑ Public Water System ❑ Public Sewer ❑ Waiver request for: Distance: Received by: Date: COSA to be released to the engineer, unless otherwise requested by the engineer. COSA Fee $ d Date of Payment a o, 0a,2 Receipt Number h l� 57 g COSA# O SG 2?l:z 3 B Waiver Fee $ Date of Payment Receipt Number Waiver # 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is (are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. I acknowledge that On -Site staff may visit the site to verify the information submitted. Name of Firm MIKE N ANDERSON, P.E. Phone 727-8864 Address 4661 NATRONA AVE ANCH AK Engineer's Printed Name MIKE N ANDERSON, P.E. Date 6-25-22 1-4 9TH •� '. A 6. DSD SIGNATURE '. • e•e ".. ' e' • ' a VSystem #1 Approved for 4 bedrooms , :• MICHAEL N. ANDDLRSCtJ•:,�4 y' System #2 Approved for bedrooms ��`s,,•, CE 94/ Disapproved l�P f . ;�• r��, 010 a�:✓ err Conditional approval for bedrooms, with the following stipulatioA_K''� \klktttd((( , \SN( ,j� �- OJER AN" r o _ ER o �011 C)ROG� P+M By_ t)-u/U 0 - Original Certificate Date: 31 /-,? 0Q 2 The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: COSA Checklist X Nitrate Advisory Septic System Advisory Arsenic Advisory Well Flow Advisory Other COSA Checklist blue sheet COSA Checklist Legal Description: THOMAS BOYLE BLK 2 LOT 11B If more than 1 septic system on lot: COSA Checklist # _of A. WELL DATA 9 Well log is filed with Onsite (or attached) Date drilled 3111/21 Total depth 77 ft Cased to 77 ft H Sanitary seal is functioning correctly X Wires are properly protected Casing height (above ground) 27"+ in. Date of flow test for COSA NEW Static water level at beginning of test 65 ft. Comments B. TANK DATA Age of tank(s) 2021 years Tank type/material STE Measured operating fluid level in septic tank NEW X Standpipes/foundation cleanout per record drawing Date of pumping new plastic STEP tank installed D. ABSORPTION FIELD DATA Which system tested (date installed) 1125121 ❑i• ALL standpipes present per record drawing Total measured depth from grade 6 ft (max) Measured depth to pipe invert from grade ft (min) ❑ N/A – pressurized field F01 Monitor tubes go to bottom of effective. If not, state depth into effective Parcel ID: 015-283-17 Structure served by this system Well production at time of test 5+ gpm Water storage tank volume 0 gallons Well disinfected for coliform test? ❑ Yes N No H Coliform bacteria is Negative Nitrate 6.56 mg/L ❑ Nitrate less than MRL (ND) Arsenic ug/L 0 Arsenic less than MRL (ND) Collected by MNA Date of Sample 4/21/22 C. LIFT STATION ❑ Required maintenance completed Age of lift station NEW years Lift station material PusnC Comments: Adequacy test date NEW Results ❑� Pass For 4 bedrooms Fluid depth prior to test _ in Water added _ gal New depth _ in Elapsed time — min 0 Code -required soil cover over field Final fluid depth _ in ❑ System presoaked Absorption rate _ gpd (Required if vacant for greater than 30 days prior to Any rejuvenation treatment (past 12 months) _ date of test)If yes, enter date 0 Gallons introduced gallons Comments/Deficiencies: COSA Checklist yellow sheet E. SEPARATION DISTANCES From Private Well on Lot to: (Please enter distances if less than required or if community well) Septic Tank/Lift Station on Lot > 100' ❑✓ Yes Community Sewer Manhole/Cleanout > 100' ✓0 Yes if No _ ft ❑r Yes if No _ ft Neighboring Tank > 100' ❑� Yes if No _ ft Private Sewer/Septic Line > 25' ❑✓ Yes if No _ ft Absorption Field on Lot > 100' [D Yes if No _ ft Holding Tank > 100' Yes if No _ ft Neighboring Absorption Fields > 100' Yes if No _ It Water Main > 10' Animal Containment > 50' Yes if No _ ft ❑✓ Yes if No ft ❑✓ Yes if No _ ft Water Service Line > 10' Yes _ Manure/Animal Excreta Storage > 100' If septic tank is under driveway Community Sewer Main > 75' ✓l Yes if No _ ft 0 Yes if No _ ft From Septic/Holding Tank on Lot to: (Please enter distances if less than required) Building Foundations > 10' ❑✓ Yes if No _ ft Surface Water > 100' ❑✓ Yes if No _ ft Property Line > 5' Yes Yes if No _ ft Wells on Adjacent Lots: Absorption Field > 5' ❑v Yes if No _ ft Private Wells > 100' Yes if No _ It Water Main > 10' Q Yes if No _ ft Community Wells > 200' ❑✓ Yes if No _ ft Water Service Line > 10' Yes if No_ ft If septic tank is under driveway comment below From Absorption Field on Lot to: (Please enter distances if less than required) Building Foundation > 10' Yes if No _ ft If absorption field is under driveway comment below Property Line > 10'✓❑ Yes if No _ ft Wells on Adjacent Lots: Water Main > 10'✓❑ Yes if No _ ft Private Wells > 100' Yes if No _ ft Water Service Line > 10' Yes if No _ ft Community Wells > 200' ❑✓ Yes if No _ ft Surface Water > 100'❑ Yes if No _ ft F. ENGINEER'S COMMENTS G. ENGINEER'S CERTIFICATION 1 certify that / have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this date. COSA Checklist yellow sheet r ��•OF ti1,��,;>�ifn r ygP. .. f...... 4 ............ : ��♦' �• MICHAEL N. ANDERSCN f . CE f9 9 4 `.. . MUNICIPALITY OF ANCHORAGE    DEVELOPMENT SERVICES DEPARTMENT    907‐343‐7904  On‐Site Water and Wastewater Section                                                                                           Fax: 343‐7997  www.muni.org/onsite         Mailing Address: P. O. Box 196650 * Anchorage, Alaska 99519‐6650 * www.muni.org      Nitrate Advisory   Certificate of On‐Site Systems Approval # OSC221238  Subdivision: Thomas L Boyle, Block: 2, Lot: 11B  A water sample revealed a nitrate concentration of 6.56 milligrams per liter (mg/L).   The  Environmental  Protection  Agency  (EPA)  has  established  a  maximum  contaminant level (MCL) of 10.0 mg/L for public drinking water systems.  While  private wells are not subject to this regulation, EPA standards are based on existing  health information and can therefore be used to gauge the relative quality of water  from private wells.  Since nitrates are known to slowly increase, we recommend  you monitor the water quality.  Please see the attached “Nitrate Fact Sheet” for  important information regarding nitrate.  This advisory must be attached to all copies of the subject Certificate of On‐Site  Systems Approval.                                 Mailing Address: P. O. Box 196650 * Anchorage, Alaska 99519‐6650 * www.muni.org  Nitrate Fact Sheet  From Northern Testing Laboratories, Inc.  Nitrate is a negatively charged compound of nitrogen and oxygen, which is very soluble in water.  Nitrate  is not readily filtered or otherwise removed in the soil and can pass rapidly into ground water wells.  SOURCE:  Nitrate is a major component of fertilizer and wastewater.  Often the nitrate is in the form of  ammonia or protein first, which through contact with oxygen and certain bacteria, converts to the  oxidized form known as nitrate.  Sources of nitrate from wastewater include urea, ammonia cleaners,  food solids, and bacterial cells.  It may also result from the breakdown of organic matter buried in the soil.  TOXICITY:  Nitrate is generally not toxic to adults or children over the age of two or three years, but is  associated with a potentially fatal infant disease called methemoglobinemia.  In the digestive system of  young children, nitrate converts to nitrite, which can pass through the intestinal wall into the blood  stream.  There it combines with the hemoglobin and interferes with the ability of the blood to carry  oxygen.  For this reason, methemoglobinemia is referred to as “blue baby” disease.  The EPA limits the  concentration of nitrate in public drinking water supplies to 10 mg/L.  The standard has been lowered  from a previous level of 45 mg/L set by the US Public Health Service and the World Health Organization.  TREATMENT: due to its solubility in water and negative ionic charge, filtration and other common home  water treatment systems such as softening or iron filtration does not readily remove nitrate.  The best  method for limiting nitrate in well water is source control.  This can include avoiding overdosing of  fertilizer near the well and maintaining good separation distances between septic tank leach fields and  the well.  A special anion exchange filter that contains a medi a with a strong affinity for negatively charged  ions in water, or by a reverse osmosis treatment system or distillation can remove nitrate.  TESTING:  Nitrate analysis is usually done by one of the several  “wet  chemical”  methods  using  a  spectrophotometer to read the final color endpoint.  Specific ion electrodes also can be used to detect  the activity of nitrate in water.  This laboratory uses several different wet chemical methods approved  under the public water supply laboratory certification program.  They also have test kits available, which  the laboratory uses to perform an inexpensive “screening test”, and with which the homeowner can  monitor the change in nitrate levels from their well.  They recommend comparing the test kit results  against a certified analysis from the lab occasionally to verify the accuracy of the kit.  We recommend  using a specially prepared bottle that has been rinsed in hydrochloric acid for collecting samples.