MUNICIPALITY OF ANCHORAGE
Development Services Department
On-Site Water & Wastewater Program
4700 Elmore Road, PO Box 196650
Anchorage, AK 99519-6650
Telephone: (907) 343-7904
Permit Effective Dates: May 08, 2013 to May 08, 2014
Design Engineer: NORTH RIM ENGINEERING
Subdivision: UPPER EAGLE RIVER ESTATES
Site Legal Address: UPPER EAGLE RIVER ESTATES BLK 2 LT 7B G:0056
Owner/Address: ROFIDAL CHAD V
20137 PTARMIGAN BLVD EAGLE RIVER AK 995770000
Site Mailing Address:
Lot Size in Sq Ft: 46722
Total Bedrooms: 4
,artment
This permit is for the construction of:
Y Disposal Field Y Septic Tank N Holding Tank N Privy Y Private Well N Water Storage
All construction must be in accordance with: 1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater
Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80).
3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services
Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either:
A. Open and Close on the same day.
B. Covered, sealed, and heated to prevent freezing.
Special Provisions: PRIOR TO CONSTRUCTION: A new testhole shall be completed to verify the
soils classification, perform a percolation test, and monitor the groundwater elevation for seven (7)
days. The findings shall substantiate the permitted design or an approved change order shall be
acquired. The contractor may proceed prior to the seven day water monitoring at his own risk.
Soils and percolation test results shall be submitted with the final inspection report.
Date:
MUNICIPALITY OF ANCHORAGE
Community Development Department
Development Services Division
On-Site Water & Wastewater Program
~ Phone:907-343-7904
Fax:907-343-7997
ON-SITE SEWER/WELL PERMIT APPLICATION
Parcel I.D. ~O""~'
Property owner(s)/~t/'(.l>.-
Mailing address /~-(~,' '~ 7
Site address ~/~ ~
Lega~ description (Sub'd., Block & Lot) ~./
Legal description (Township, Range & Section)
Lot Size ~ ( A~ .Sq. Ft. Number of Bedrooms
Day phone
APPLICATION IS FOR: APPLICATION IS AN:
([~ all that apply)
^bserption Field
Septic Tank Upgrade
Holding Tank ' Renewal []
Privy []
Private Well
Water Storage
TYPE OF DWELLING:
Single Family (SF)
(w/wo ADU)
Duplex (D).
Multiple Dwellings (SF and/or D)
THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR:
Distance:
applicable Municipal Codes.
(Signature o~dy~owner or autho gent) /
Permit/Rush Fees: ~ '~-'..~"
Date of Payment: ,,,~, :~, _/~
Receipt Number:
Permit No. ~]
I certify that the above information is correct. I further certify that this is in accordance with
Waiver Fees:
Date of Payment:
Receipt Number:
Waiver No.
MEMO
Steve Eng, PE, PH
(907) 694-7028 tel
NorthRimEng@aol.com
Date: 5/1/13
To: Jay Crewdson, PE
MOA On-Site Services
Number of Pages: 5
Subject: Upper Eagle River Estates, Block 2, Lot 7B
Jay,
! followed your direction for septic system design. This system is designed to previous soils
information. Soils will be verified prior to construction. Good soils exist in the area. A proposed
well is sited.
If there is need for additional information or clarification please give mc a call.
Thanks-Steve
iX THRIM , ,:
I ~<~[?EERING PE.: o2,s-: ' "' 7B, Block 2
,_ '..'Upper Eagle River Estates, Lot
Wastewater System Sizing: This is a proposed 4-bedroom, single family home. Most of
the neighboring lots are developed. A test hole was completed in 1984 that is the basis for
design. New test holes will be completed during construction to verify the soils. These
lots are large and are served by private wells. No adverse impacts are expected from
development. No conflicts to the other lots will take place by this septic system
construction. The lot easement is located on the dxawing and is not encroached upon.
Previous soil tests reveal poorly graded gravel. An application rate of 125 FTZ/Bedroom
is being used. 125 FT2/Bedroom x 4 Bedrooms = 500 FT2, Trench Length = 500 FTV 5~
x 0.5 reduction = 50'; 1 line ~ 50'. Soil and groundwater will be verified prior to
construction. Groundwater monitoring may take place during construction.
Specification Requirements: All components and work must comply with the
Municipality of Anchorage Specifications (AMC) & State of Alaska Drinking Water
Regulations and Wastewater Regulations.
· Two compartment, 1250 gallon septic tm~k. Watertight couplings on inlet & outlet.
· 5' minimum between the tank and bed. 10' to property lines.
· 3' of cover or insulation is required for trench; an equivalent of 1" insulation for
1' foot soil cover.
· Tank & solid pipe must be set on well compacted, stable soil.
· 4 inch diameter cleanouts with airtight caps are required 1' to 4' from foundation
wall, prior to any 90 degree bend in 4 inch line, in each tank compartment, and two
adjacent opposing cleanouts between the tank and the absorption field, not more than
10' from the tank positioned to provide cleanout access towards the tank and towards
the absorption field.
· All cleanonts must extend to at least ground level.
· In solid pipe runs, ASTM D-3034 may be used in lieu of cast iron.
· Trench to be placed level, minimum of 4' to groundwater, 6' to bedrock from drain-
rock.
· Drain rock to be ½ inch to 2 ½ inch screened. Drain rock to be distributed uniformly
throughout the trench.
· Perforated pipe to be installed level with perforations down.
· Silt barrier (filter fabric) to be installed above the drain rock.
· Smeared trench sides must be raked or scarified before drain rock placement.
· The finish grade must be mounded to promote drainage over the trench.
· Insulation must be placed over any pipe installed under driveways or parking areas.
· Approved pipe materials include cast iron, PVC ASTM D3034, PVC ASTM F789,
ABS ASTM D2661,
· Sewer Service Line is minimum 2% slope.
· Septic Tank to be pumped every two years or when required.
· Insulation board to be extruded direct burial polystyrene (Dow Styrofoam HI/equal)
Z
U
0
[3_
tx)
W
W
E°
Z (~
W W
U
C
v
C
u
c-
0
c
r~
>
O O O
(,9 ~-~-
~ c
0 O)
c~ Ub-I
O_ O ~-
E (D O
O .I2
O ~
~ ~ O
~ ~ ---cU
O ~ ~ ~--~
~ O E
~
MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION
SOILS LOG -- PERCOLATION TEST
SOILS LOG
PERCOLATION
TEST
LEGAL DESCRIPTION; ~. ~ 7~,
1
2
3
4
6-
7-
8-
9-
10
12
13
. 14-
15.
16-
17-
19-
20
'' SLOPE Sl['~ PLAN
ENCOUNTERED? , ',
IF yr,$, AT WHAT
PERCOLATION RATE
TEST RUN ~E'CWEEN . - - ET AND . - FT
OATE;~