ON-SITE SEPTIC/WELL PERMIT APPLICATION
FOR A SINGLE FAMILY DWELLING
Parcel I.D.
Properly owner(s)
Legal description (Sub'd, Block & Lot) _ ~,(
Legal description (Township, Section & Range)
Day phone
Zip Code
Zip Code
Lot Size ~,'~ ~¢~ ~ Sq. Ft. Number of Bedrooms
THIS APPLICATION IS FOR ([~all that apply): THIS APPLICATION IS AN:
Absorption Field ~'~ Initial []
Septic Tank F~'~ Upgrade []
Holding Tank [] Renewal []
Privy []
Private Well []
Water Storage []
certify th(at/~/,e ~tb/o'/ve inCd~ion is correct. I further certify that this application is being made fora
Single]la Fa~}~Fa ti~ D et'ii ~/~sin accordance with applicable Municipal Codes.
(Signature of property owner or authorized agent)
PermitJRush Fees:
Date of Payment:
Receipt Number:
(Rev. 11/05}
Waiver Fees:
Date of Payment:
Receipt Number:
Phone (907) 745-0222
Fax (907) 746-0222
akrim@ rogershsa,com
RO. Box 2749
Palmer, Alaska 99645
February 1, 2006
Mr. Greg Wilkins
Criterion General
2820 Commercial Dr.
Anchorage, AK 99501
RE:
Lot 15, Block 3, Wynter Park #1 Subdivision
Proposed Wastewater Disposal Plan
AK. Rim Engineering Ref. No. 0400712
Dear Mr. Wilkins:
This letter is to provide you with a proposed wastewater disposal plan for the above referenced
property, located within the Municipality of Anchorage (MOA). Our site work to date has shown
that in order to install an onsite septic system on this lot it is required that you maintain a 100 feet
setback to the drainage easement that passes through the lot. And it does not appear possible
to achieve that goal with the existing available area of the lot in relation to the drainage
easement.
It is proposed that in order to install an onsite septic system a culvert be installed within the
drainage easement, the length of which will be completely encompassed within the 100 feet
setback to the proposed location of the onsite septic system bed (including replacement bed).
This would mean that there will be no open flow of water inside of the 100 feet setbacks to all
parts of the septic system.
The attached drawing shows the proposed 18-inch CPP (corregated plastic pipe) culvert to be
installed in the drainage easement. The drawing also shows the proposed layout of the house
and the septic system, including the septic tank and drainfield beds (see attached). The 100-feet
setbacks from all portions of the septic system are shown on the drawing, and the culvert is
shown to extend beyond those setbacks. The house and the septic system are also shown to be
outside of the 30 feet drainage easement setback, as well as the 10 feet property line setbacks.
All the MOA-required setbacks for onsite septic systems have also been taken into consideration.
It should be noted that this design must be approved by MOA prior to construction. The
dimensions listed on the drawing are based on dimensions taken from the plat and from field
measurements using hand-held instruments. It is recommended that prior to construction all
locations and setbacks be staked by surveyors.
Engineers · Planners · Surveyors
Mr. Greg Wilkins
Page 2
February 1, 2006
If you have any questions regarding this proposal, please feel free to contact me at the above
numbers, or at marys@alaskarim.com.
Sincerely,
ALASKA RIM ENGINEERING, INC.
Mary L. Shreves
Professional Engineer
CC: AK Rim Engineering File No. 04-00712
Attachments:
· Revised Site Plan
1" 50' ° ~
260 ~ ~ OF SEPTIC T,AhJK
.0~' ~ 60
NOTES:
1, DRAINAGE ESMT LOCATED BY HAND MEASUREMENTS AND NOT ESTABLISHED BY SURVEY.
2. SOIL ABSORPTION BED SIZED ACCORDING TO MOA CH, 15.65.060 C AND AKTH1 PERC,
5, THIS SUBDIVISION IS SERVED BY A COMMUNITY WATER SYSTEM.
4. CPP = CORREGATED PLASTIC PIPE,
EXCLUSION NOTE: IT IS THE RESPONSIBILITY OF THE OWNER OR BUILDER, PRIOR TO CONSTRUCTION, TO VERIFY PROPOSED
BUILDING GRADE RELATIVE TO FINISHED GRADE AND UTILITIES CONNECTIONS, AND TO DETERMINE THE EXISTENCE OF ANY
EASEMENTS, COVENANTS, OR RESTRICTIONS WHICH DO NOT APPEAR ON THE RECORDED SUBDIVISION PLAT.
~>~__%_~_ ~,,~ ,~ SiTE P~N .~,,
I ao~, P.O. BOX 2749
~}~.' ~ -' '.~ ~ F~X: (907)746-0222
..~*/49TH.~ ~ X*~, W.O. 0400712IDATE: 3/21/00 ISCALE: 1"=
~""~' ............ ~ ..... ~.~.~ 50' ~ FLEE: 0400712_~
~-'. CE 9351 .':~ P~T No. 73-149, ANCHO~GE RECORDING DISTRICT, ANCHO~GE, A~
~". ......... " ~ ~SEMENTS OF RECORD OTHER THAN THOSE SHOWN ON THE
~ E~ RECORDED P~T ARE NOT SHOWN HEREON.
NO0 O, 2,5
NO0~O 3 25":W
8/0,24
F[RNDALE
Municipality of Anchorage
Development Services Department
Building Safety Division
On-Site Water and Wastewater Program
4700 Bragaw Street
P.O. Box 196650
Anchorage, Alaska 99519-6650
www. muni.org/onsite
(907) 343-7904
ON-SITE SEWER/VVELL PERMIT APPLICATION
FOR A SINGLE FAMILY DWELLING
Parcel I.D. 05149234-000
Property owner(si Greg Wilkins
Mailing address ~28"'2(~ci~[r~)~ve~A~cherage /
Site address 20918 Femdale Street, Chugiak
Day phone ~88~2~
Z,.co.e z
Zlp Godo
Legal description (Sub'd., Block & Lot) Lot 15, Block 3, Wynter Park #1 Subd.
Legal description (Township, Range & Section)
Lot Size 22,397 .Sq. Ft.
Number of Bedrooms 3
THIS APPLICATION IS FOR ([~ all that apply): THIS APPLICATION IS AN:
Absorption Field [] Initial
Septic Tank [] Upgrade
Holding Tank [] Renewal
Privy []
Private Well []
Water Storage []
I certify that the above information is correct. I further certify that this application is being made for a
Single Family Dwelling and is in accordance with applicable Municipal Codes.
(Signature of property owner or authorized agent)
Permit/Rush Fees:
Date of Payment:
Receipt Number:
(Rev. 11/05)
Waiver Fees:
Date of Payment:
Receipt Number:
Phone (907) 745-0222
Fax (907) 746-0222
akrim @ rogershsa.com
RO, Box 2749
Palmer, Alaska 99645
March 23, 2006
Mr. Jeff Poet
Municipality of Anchorage
Development Service Department
Building Safety Division
On-Site Water and Wastewater Program
PO Box 196650
Anchorage, AK 99519-6650
RE:
Lot 15, Block 3, Wynter Park #1 Subdivision
On-Site Sewer Permit Application
AK. Rim Engineering Ref. No. 0400712
Dear Mt. Poet:
The owner of the above referenced lot is proposing to construct a 3-bedroom single
family dwelling (see attached Site Plan). The proposed dwelling is to be served by a
community water system and a private septic system. With this letter we are requesting
plan review and a permit to install an onsite septic system to serve the proposed
development.
DESIGN SUMMARY
Soils
A test hole was excavated on 9/13/04, and a monitor tube installed. A percolation test
was conducted in the same location. The attached Soirs Log - Percolation Test form
shows the approximate location of the test hole, labeled TH #1. The soils were rated in
the field as SP, sand with gravel. The percolation test indicates a soil percolation rate of
13.3 minutes per inch which translates to a wastewater application rate of 0.5 gpd/sqft for
an absorption bed system.
Groundwater seeps were encountered at 8.5 feet below ground surface during the initial
excavation of the test hole. On 10/15/04, the monitor tube was probed and groundwater
was detected at 5.99 feet below ground surface. A setback of 4 feet is applied between
the elevation of the bottom of the proposed bed and the high groundwater elevation.
Equivalent cover of 4 feet will be achieved over all portions of the SAS, including the
septic tank and bed.
The owner of the property has excavated numerous areas of this lot and stated the soil
conditions are consistent throughout the lot. We are proposing that at the time of
installation of the drainfield, a test hole will be dug in the area of the replacement field,
and at that time a percolation test be conducted and a groundwater monitor tube be
installed for verification of groundwater levels.
Engineers · Planners · Surveyors
Mr. ~leffPoet, MOA
Page 2
March 23, 2006
Trench Design
The following is a summary of the proposed design of the bed SAS:
Pemolation rate: 13.3 minutes/inch
Soil application rate: 0.5 gpd/sqft
Number of bedrooms: 3
Daily wastewater flow: 450 gpd
Drainfield: absorption bed
Septic tank: 1,000 gallons
Minimum absorption area: 900 sqft
Total depth (max): 1.99 ft
Length: 60 ft
Width: 15 ft
Effective absorption area: 900 sqfl
Topography
The subject lot slopes evenly frem northeast to southwest, with the west portion of the lot
rising sharply. There are no downslopes 25% or greater within 50 feet of the proposed
SAS.
Surface Water
There is a 30 feet drainage easement that passes through the lot following the slope
contours (see attached Site Plan). This easement flows with surface water drainage frem
offsite. The owner is proposing to install an 18-inch CPP (Corregated Plastic Pipe)
culvert within the easement, to take up all flow that is potentially within 100 feet of the
proposed SAS. The attached Site Plan shows 100 feet setback radii frem all corners of
the original and replacement SAS. The culvert will extend beyond all 100 feet setbacks,
therefore there will be no surface water within 100 feet of the SAS.
Surrounding Properties
This property will be served by a community water system that serves the parent
subdivision. We are unaware of any adverse impacts this installation would have on
adjacent wells or septic systems. If you have any questions regarding this report or its
recommendations, please feel free to contact me.
Sincerely,
ALASKA RIM ENGINEERING~ INC.
Mary L. Shreves
Professional Engineer
CC:
Greg Wilkins
AK Rim Engineering File No. 0400712
Mr. JeffPoet, MOA
Page 3
March 23, 2006
Attachments:
· MOA On-Site Sewer ! Well Permit Application Form
MOA Soils Log - Percolation Test Form
· Site Plan
· Septic Design
NOTES:
1. DRAINAGE ESMT LOCATED BY HAND MEASUREMENTS AND NOT ESTABLISHED BY SURVEY.
2. SOIL ABSORPTION BED SIZED ACCORDING TO MOA CH. 15.65.060 C AND AKTH1 PERC.
5. THIS SUBDIVISION IS SERVED BY A COMMUNITY WATER SYSTEM.
4. CPP - CORREGATED PLASTIC PIPE.
EXCLUSION NOTE: IT IS THE RESPONSIBILITY OF THE OWNER OR BUILDER, PRIOR TO CONSTRUCTION, TO VERIFY PROPOSED
BUILDING GRADE RELATIVE TO FINISHED GRADE AND UTILITIES CONNECTIONS, AND TO DETERMINE THE EXISTENCE OF ANY
EASEMENTS, COVENANTS, OR RESTRICTIONS WHICH DO NOT APPEAR ON THE RECORDED SUBDIVISION PLAT.
SITE PLAN
~..~,,%%'%%'~'~,, ...... .,~ P.O. BOX 2749
~ QF ~;~ K~w~u ~ ~ PALMER, A~SKA 99645
~&~-" A '"-~h ~C~Z~C. PHONE: (907)745-0222
~¢. ~ ..,.¢ v~ ~ ~% FAX: (907)746-0222
~¢*/49TH~,,. ~,A. ~ W.O. 04007121DATE: 3/22/06 ISCALE: 1"= 50' IFILE: 0400712_~4
%~'.. CE 9551 ..:~ P~T No. 75-149, ~CHO~GE RECORBIN~ Dl~l~,
~.¢~... ...-~
.~:t~ ........ .. ~ EASEMENTS OF RECORD OTHER THAN THOSE SHOWN ON THE
~b.~.~rb~'"'~ RECORDED P~T ARE NOT SHOWN HEREON.
IT IS THE RESPONSIBILITY OF THE OWNER OR BUILDER
PRIOR TO CONSTRUCTION TO VERIFY PROPOSED BUILDING
GRADE }~EI,ATIVE TO FINISHED GRADE AND UTILITY
CONNECTIONS. AND TO D.~,~I'~INE THE EXISTENCE OF ANY
EASEMENTS, 'coVENANTS OR RESTRICTIONS WHICH DO NOT
APPEAR ON THE REDOEDED SUBDIVISION PLAT.
NOTE:ELEVATIONS ARE ASSUMED DATUM.
PROPOSED CONSTRUCTION PLAN
I HEREBY CERTIFY .THAT I HAVE SURVEYED THE
FOLLOWING DESCRIBED PROPERTY,
AND THAT NO ENCROACHMENTS EXIST E3(CEPT AS
INDICATED. tT IS THE RESPONSIBILITY OF THE
OWNER TO DETERMINE THE EXISTENCE OF ANY
EASEMENTS~ COVENANTS, OR RESTRICTIONS
'HICH DO NOT APPEAR ON THE RECORDED SUBDI-
PLAT. UNDER NO CIRCUMSTANCES SHOULD
~,NY DATA HEREON BE USED FOR OONSTRUCTION
OF FENCE LINES, OR FOR ESTABLISHING BOUND-
'~RY LINES.
S~?ARD &
SCALE~
DATE~ / /
GRID"
ASSOCIATES LANiD SURVEYING 694-0829
ABSORPTION BED W/ CENTER HEADER
PLAN VIEW (~.1~
SECTION X-X
Conven[ional Single Family Residen[ial
SEPTIC SYSTEM DESIGN
~' ~t 15, Block 3, W~ter Park ~1
T~S ~cord the ~-eonst~oted condition of the improvemen~ doe~en~d
da~ appears ,~,sonabl~ ~d represen~, that the p~]ect was cons~u~ted
Municipality of Anchorage
Development Services Department
Building Safety Division
On-Site V~ter and Wastewater Program
4700 South Bragaw St.
P.O. Box 196650 Anchorage, AK 99519~650
www.ci.a nchoraae.alcus
(907) 343-7904
Soils Log - Percolation Test
Performed For:. Greg Wilkins
Legal Description: Lot 15, Block 3, Wynter Park #1
5-
6-
7-
-- 9-
10-
Township, Range, Section:
11-
12-
13-
14-
15-
16-
17-
18-
19-
20-
WAS GROUND WATER
ENCOUNTERED? Yes
8
L
IF YES, AT V~HAT DEPTH? 8,5* O
Del~fl to Water Aft~r p
D~: 10/15/04
COMMENTS Presoak 6 hours
Site plan
Re. ding DMe Gross Time Net Time Depth to ~at er Ne{ Drop
1 9/13/04 1456 30 min 2-1/4"
2 - 1527 30 rain 2-1/4"
3 - 1558 30 rain 2-I/4' 2-1/4"
PERCOLATION PJ~.TE 13.3 (,"rUral PERC HOLE DU~METER 6-in.
TEST RtJN BE~IWEEN 3.5 ET AND 4.0 FT
PERFORMED BY: Kent Sheets I Mary L. Shmves, P.E. CERTIFYTHATTHIS TESTW~
PERFORMED IN ACCORDANCE VVITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DA'rE. DATE: 11/4/04
Page 1 of 1
Crewdson, James A.
From: Crewdson, James A.
Sent: Wednesday, April 04, 2012 4:29 PM
To: 'Mary S.'
Cc: ron@alaskarim.com
Subject: RE: Lot 15 Block 3 Wynter Park 1
Thanks for the update. This should be enough for me to do my part in the puzzle.
,lames ",Toy" Crewdson, P.E.
Civil Engineer
Municipality of Anchorage - Development Services Division
On-Site Water and Wastewater Program
Location: 4700 Elmore Read
Mail: P.O. Box 196650, Anchorage, AK 99519
v. 907.343.7908 f. 907.249.7601
From: Mary S. [mailto:marys@alaskarim.com]
Sent: Wednesday, April 04, 2012 4:17 PM
To: Crewdson, .~ames A.
Cc: ron@alaskarim.com
Subject: Lot 15 Block 3 Wynter Park 1
This project is on hold (and the file closed) in our office. We have had no contact from our client, Mr. Greg
Wilkins, since 2009. As far as we can tell this issue is not progressing on his part. Unless we hear from
him we will not be performing any additional work on this project. If you want to discuss the details of the
project to date, I can give you a call.
Thank you,
Mary L. Shreves, P.E.
AK Rim Engineering, Inc.
Palmer, AK
907-745-0222
907-746-0222 fax
CONFIDENTIALITY NOTICE: This email message including any attachments is for the sole use of the
intended recipient(s) and may contain confidential and privileged information. Any unauthorized review,
use, or disclosure is prohibited. Sender is to be held harmless for any liability resulting from information
sent unintentionally.
4/4/2 012
ipality of Anchorage
aent Services Dapartment
Building Safety Division
Water and Wastewater Program
4700 South Bragaw St.
3650 Anchorage, AK 99519-6650
www. ci.anchorage.ak.us
(907) 343-7904
~VELL SUBMITTAL COMMENT SHEET
[~;~]Permit [--IC.O.S.A. r-Ilnspection Report
The attached paperwork has been reviewed and is being returned for the following reasons:
1.-SURFACE WATER IN PIPE?
2.-PIPE WORK ON OTHER PROPERTIES?
3. -WELL?
4. -TESTHOLE?
Name of reviewer: JOE
Date: January 7, 2008
Please supply the necessary information and re-submit your request.
LEAVE THIS FORM ATTACHED TO THE PAPERWORK