On-Site Water and Wastewater Section • (907) 343-7904 Page 1 of 3
ON-SITE WASTEWATER INSPECTION REPORT
Permit Number: OSP201418 PID Number: 018-322-24
Dwelling: ❑ Single Family (SF) ❑ with ADU ❑ Duplex (D) ❑ Two Single Family Project: ®❑ New ❑ Upgrade
Name
St. Tikhon Russian Orthodox Church
ABSORPTION FIELD
❑ Deep Trench FE1 Wide Trench ❑ Bed ❑ Mound
Site Address
NHN Old Seward Highway Anchorage, AK 99516
❑ Other
Phone
Number of Bedrooms
Soil Rating
Total depth from original grade
907-830-6211
4
1.2 GPD/SF
1.6 Ft.
LEGAL DESCRIPTION
Depth to pipe invert from original grade
+0.4 Ft.
Gravel depth beneath pipe
2.0 Ft.
Subdivision Block Lot
Gold Pan Estates 3
Fill added above original grade
4.3 Ft.
Gravel length
70 Ft.
Township Range Section
Gravel width
5 Ft.
Beds: Number of Lines
N/A
Distance between lines
N/A Ft.
SEPARATION DISTANCES
To
Septic
Absorption
Lift Station
Holding
Sewer
Total absorption area
Number of trenches
Dist. between trenches
From
Tank
Field
Tank
Line
500 Ftz
1
N/A Ft.
Well
>100'
>100'
N/A
N/A
>25'
TANK ❑ Septic Fm] S.T.E.P. ❑ Holding [:]Other
Manufacturer
Greer
Capacity
1500 Gal.
Surface Water
>100'
>100'
N/A
N/A
Material
Plastic
Number of compartments
2
Lot Line
>5'
>10'
N/A
NIA
NA
Foundation
> 10'
> 10' j
N/A
. N/A
LIFT STATION
Manufacturer
Greer
Capacity
250 Gal.
Remarks
Alarm location
Southern Exterior Wall / Inside Garage
Electrical installed by
Dependable Electrical Services
Installer
PIPE MATERIAL House to tank D3034 Tankto
D3034
John's Excavating
Drainfield D3034 CO/MTD3034
Inspector L.Tidwell
BENCH MARK (Assumed elevation) 100 ft
Inspdectio 15` 11/11/20 11/13/20
Location and description
2�d
Bottom of siding on SE corner of home
3b 11/13/26 411
ON-SITE WATER AND WASTEWATER SECTION APPROVAL
Engineer's Stamp
",�
-
Conditional Approval: Date
•'��
.tS'L
• Benjarrr =Schiller
�F��s,,.
Septic stem %J�
`%�
Approved'" �,X a 8 o2p.2
Date
CE 12592��
l* z/...
, ��, •
��� pROFESSIO.
Note: this approval does not include well permit requirements.
tRev uo/uu-i o/
1"=50'
70' LONG x 5' WIDE x 2'
EFFECTIVE DEPTH
ABSORPTION TRENCH
4-BDR
M
H
O
M
E
1,500-GALLON
S.T.E.P. TANK
w/2-20" MANWAYS
CO - CLEANOUT
2CO - DOUBLE CLEANOUT
FCO - FOUNDATION CLEANOUT
FS - FLOW SPLITTER VALVE
MH - MANHOLE
MT - MONITORING TUBE
SV - SEPTIC VENT
TH - TEST HOLE
LEGEND
TH#1
PERMIT # OSP201418 PID # 018-322-24
GOLD PAN ESTATES, LOT 3
A B
FCO 36.7
MH1 35.4
MH2 38.6
A
B
CO1 60.3
MT1 61.8
CO2 38.7
MT2 36.05
4.2
36.4
40.1
51.4
53.4
74.9
72.3
O
L
D
S
EW
A
R
D
H
I
G
HW
A
Y
FEET
0 50 100
75' ROW EASEMENT
(BK 1147, PG 611)
10' UTILITY EASEMENT
10' UTILITY EASEMENT
20' ACCESS EASEMENT
CLASS A WELL w/200' RADIUS
115110
MT1
M
H
2
M
H
1
MT2
FCO
ALTERNATE SITE: CATEGORY III
SYSTEM w/20' LONG x 5' WIDE x 2'
EFFECTIVE DEPTH ABSORPTION
TRENCH. 5.0 GPD/SF APP. RATE.
EXISTING WELL
C01
C02
PLAN AS-BUILT
4" TO 112 "
COUPLER
PERC.
1/26/22
³6'
70'
PROFILE AS-BUILT
(NO SCALE)
92.6
86.1
93.2
97.1FCOMH1 MH21500 GAL
STEP TANK
99.5 FINISH GRADEMT1
TH#187.7 GROUNDWATER 11/4/20
95.6 CO1CO277.2
95.6
95.2 ORIGINAL GRADE MT2PERMIT # OSP201418 PID # 018-322-24
GOLD PAN ESTATES, LOT 3
93.693.6
DRAINFIELD ROCK
12/23/21
LEGAL DESCRIPTION:
PERFORMED FOR:
DATE:
PARCEL ID#:
SOILS LOG AND PERCOLATION TEST
TECHNICIAN:
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
DEPTH
(feet)
PROJECT No.:
PERC. TEST
SLOPE
SLOPE
SITE PLAN
DATE READING GROSS TIME(minutes)NET TIME(minutes)
DEPTH toWATER NET DROP
PERC. HOLE DIA. (INCHES)PERCOLATION RATE: (MIN/INCH)
TEST RUN BETWEEN: FT. and FT.
COMMENTS:
(inches)(inches)
GOLD PAN ESTATES, LOT 3
11/12/2020
L.TIDWELL
DATE OF MONITORING:
WAS GROUND WATER ENCOUNTERED?
DEPTH TO WATER AFTER MONITORING:
IF YES @ WHAT DEPTH?
2.16 6"
3 4
018-322-24
ST. TIKHON RUSSIAN ORTHODOX CHURCH
Professional Engineers Stamp:
3
4
2
1
10
10
5
6 10
11/12/20
12:45
12:58
1:10
1:20
1:32
1:43
10
10
10
See Site Plan
0-58 16 58 16
57 16
413 16
41116
41116
410 16
0-57 16
0-413 16
0- 41116
0-41116
0-410 16
2/8/22
Z2
PO BOX 240773
ANCHORAGE, AK 99524
522-7773 677-7766 (FAX)
November 6, 2020
M.O.A. Development Services Department
On-Site Water & Wastewater Program
4700 Elmore Road
Anchorage, AK 99507
Subject: Gold Pan Estates, Lot 3 – NHN Old Seward Highway
Septic System Design
Dear On-Site Services Engineer:
The owner of Lot 3, Gold Pan Estates Subdivision intends to construct a new four-bedroom home
on the lot. We are therefore requesting a permit be issued for the construction of a new septic
system to accommodate the home. Water to the home will be provided from the Class A Well
and Water System on the adjacent lot. The attached Site Plan and backup documentation identify
the location and configuration of the proposed septic system along with the alternate site. Also
identified on the plans are the existing wells and septic systems on surrounding lots. No conflicts
exist between the proposed septic system and well or septic systems and wells on adjacent lots.
The ground surface on the lot in the area of the septic system slopes to the southwest. The new
trench will be constructed parallel with the contours of the slope as much as possible in
conformance with Municipal requirements. The new septic system will be constructed a minimum
of 200’ from the Class A well and 100’ from all private wells and any surface water and 10’ from
the proposed and existing water services in the area. Ground surface contours are shown on the
Site Plan. Storm water drainage will not affect the proposed septic system.
Groundwater was recently found at 7.5’ below the surface. No groundwater was found during
placement of the test hole in late June of 2013 to a depth of 18’. It is thought that much of the year
the area is free of groundwater to depths of at least 18’. The lot immediately to the south with a
test hole approximately 200’ away indicated no groundwater to 14’ on 10/22/19. Similarly, the
lot directly to the southwest and approximately 250’ away indicated no groundwater to 20’ on
8/13/2018. The ground surface approximately 500’ to the south ends in a steep slope which drops
rapidly toward Cook Inlet. We can logically assume the groundwater found recently on Lot 3 is
at or near its highest level of the year and should start to drop immediately as the fall rains have
now ceased. The absorption trench for the proposed septic system on this lot is designed for a
CO#1
groundwater elevation of 7’ which is .5’ higher than the elevation of the water recently encountered
on site. We are confident this is more than acceptable to meet current Municipal Code.
Please refer to the attached test hole log and plan and profile sheets for the septic design. If this
design is followed, there will be no adverse impacts to adjacent properties.
Sincerely,
Michael E. Anderson, PE
11/6/20
1"=50'
70' LONG x 5' WIDE x 2'
EFFECTIVE DEPTH
ABSORPTION TRENCH
4-BDRM
H
O
M
E
1,500-GALLON
S.T.E.P. TANK
w/2-20" MANWAYS
NOTE:
NO SLOPES >25% WITHIN 50' OR SURFACE WATER WITHIN 100' OF THE
PROPOSED SEPTIC SYSTEM
ALL WELLS ON SURROUNDING LOTS WITH IMPACTS TO THIS
PROPERTY ARE SHOWN. NO CONFLICTS WITH WELLS OR SEPTIC
SYSTEMS.
CO - CLEANOUT
2CO - DOUBLE CLEANOUT
FCO - FOUNDATION CLEANOUT
FS - FLOW SPLITTER VALVE
MH - MANHOLE
MT - MONITORING TUBE
SV - SEPTIC VENT
TH - TEST HOLE
LEGEND
GOLD PAN ESTATES, LOT 3
O
L
D
S
E
W
A
R
D
H
I
G
H
W
A
Y
11/6/20 FEET
0 50 100
75' ROW EASEMENT
(BK 1147, PG 611)
10' UTILITY EASEMENT
10' UTILITY EASEMENT
20' ACCESS EASEMENT
CLASS A WELL w/200' RADIUS
1
1
5
110 MT
MH
MH
MT
TH
FCO
ALTERNATE SITE: CATEGORY III
SYSTEM w/20' LONG x 5' WIDE x 2'
EFFECTIVE DEPTH ABSORPTION
TRENCH. 5.0 GPD/SF APP. RATE.
EXISTING WELL
CO#1
GOLD PAN ESTATES, LOT 3
DESIGN FACTORS:SYSTEM REQUIREMENTS:
600 GPD PEAK FLOW
PERK RATE: 1.4 MIN/IN
APPLICATION RATE: 1.2 GPD/SF
5' WIDE TRENCH SYSTEM
1,250-GALLON SEPTIC TANK
TYPICAL TRENCH SECTION
(NO SCALE)
2" INSULATION &
GEOTEXTILE FABRIC
DRAINFIELD ROCK
5'
6"
1.5'
2'
NOTES:
1.GRADE AREA OVER TRENCH TO DRAIN AWAY
2.PROVIDE 3' OF COVER OVER TRENCHES AND 4' OVER SEPTIC TANK, OR 2'
WITH 2" OF INSULATION
3.CHECK GROUNDWATER AT TIME OF CONSTRUCTION. IF LEVEL IS HIGHER
THAN PREVIOUSLY OBSERVED, CALL ENGINEER IMMEDIATELY
BOTTOM OF TRENCH: 3.0' BELOW GRADE
FLOW LINE ELEVATION: 1.0' BELOW GRADE
TOP OF TRENCH:1.5' ABOVE GRADE
600 GPD / 1.2 GPD/SF /5' WIDE * .7 (RED. FACTOR) = 70 LF TRENCH REQUIRED (70 LF SPECIFIED)
11/6/20
4" PERFORATED PVC
(HOLES DOWN)
6"OG OG
30 - 516" HOLES @ 2.33' SPACING
CO#1
LEGAL DESCRIPTION:
PERFORMED FOR:
DATE:
PARCEL ID#:
SOILS LOG AND PERCOLATION TEST
TECHNICIAN:
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
DEPTH (feet)
PROJECT No.:
TEST HOLE 1
5.12'
5.12'
5+6'2.#0
'4'#&+0))41556+/'
OKPWVGU0'66+/'
OKPWVGU
&'26*VQ9#6'4 0'6&412
PERC. HOLE DIA. (INCHES)PERCOLATION RATE: (MIN/INCH)
TEST RUN BETWEEN: FT. and FT.
COMMENTS:
KPEJGU
KPEJGU
)1.&2#0'56#6'5.16
,$
DATE OF MONITORING:
WAS GROUND WATER ENCOUNTERED?
DEPTH TO WATER AFTER MONITORING:
IF YES @ WHAT DEPTH?Ä
1.4 6"
4 5
RKF
566+-*104755+#0146*1&1:%*74%*
1' OB
Professional Engineers Stamp:
11/6/20
0Q
3
4
2
1
10
10
5
6 10
6/27/13
3:10
3:21
3:32
3:43
3:54
4:05
1.25"/8.50"
1.13"/8.38"
1.25"/8.38"
1.06"/8.19"
1.13"/8.25"
1.25"/8.38"
7.25"
7.13"
7.13"
10
10
10
7.25"
7.13"
7.13"
MEASUREMENTS TO THE 1/16".
GW/GM
5GG5KVG2NCP
B.O.H.
CO#1
On-Site Water & Wastewater System Permit
OSP131187
01832224000
WellSeptic
MUNICIPALITY OF ANCHORAGE
Development Services Department
On-Site Water & Wastewater Program
4700 Elmore Road, PO Box 196650
Anchorage, AK 99519-6650
Telephone: (907) 343-7904
Permit Number:
Tax Code Number:
Work Type:
Permit Effective Dates: August 13, 2013 to
Design Engineer: ANDERSON ENGINEERING
Subdivision: GOLD PAN ESTATES
August 13, 2014
Site Legal Address: GOLD PAN ESTATES LT 3 G:3134
Owner/Address: SAINT TIKHON RUSSIAN ORTHODOX
CHURCH 15396 OLD SEWARD HWY ANCHORAGE AK 995163954
Site Mailing Address: 15420 Old Seward HWY, Anchorage
Lot Size in Sq Ft:
Total Bedrooms:
39207
3
)artment
This permit is for the construction of:
Y Disposal Field Y Septic Tank N Holding Tank N Privy Y Private Well N Water Storage
All construction must be in accordance with: 1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and '15.65 and the State of Alaska Wastewater
Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80).
3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services
Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either:
A. Open and Close on the same day.
B. Covered, sealed, and heated to prevent freezing.
MUNICIPALITY OF ANCHORAGE
Community Development Department
Development Services Division
On-Site Water & Wastewater Program
Phone: 907-343-7904
Fax: 907-343-7997
ON-SITE SEWERANELL PERMIT APPLICATION
Parcel I.D. 018-322-24
Property owner(s) Saint Tikhon Russian Orthodox Church Day phone
Mailing address 15396 Old Seward Highway Anchorage, AK 99516
Site address
Old Seward Highway Anchorage, AK 99516
Legal description (Sub'd., Block & Lot) Gold Pan Estates, Lot 3
Legal description (Township, Range & Section)
Lot Size 39,207 _Sq. Ft. Number of Bedrooms Three (3)
APPLICATION IS FOR:
([~ all that apply)
Absorption Field []
Septic Tank []
Holding Tank []
Privy []
Private Well []
Water Storage []
APPLICATION IS AN:
TYPE OF DWELLING:
Initial [] Single Family (SF)
(w/wo ADU)
Upgrade []
Duplex (D)
Renewal []
Multiple Dwellings
(SF and/or D)
THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR:
Dis tance:
I certify that the above information is correct. I further certify that this is in accordance with
applicable Municipal Codes.
(Signature of property owner or authorized agent)
Permit/Rush Fees:
Date of Payment:
Receipt N umber:
Permit No.
Waiver Fees:
Date of Payment:
Receipt Number:
Waiver No.
July 7, 2013
Municipality of Anchorage
Development Services Department
On-Site Water and Wastewater Program
4700 South Bragaw Street
Anchorage, AK 99519-6650
Subject:
Lot 3, Gold Pan Estates Subdivision
Septic System Design and Permit Application
Impacts to Adjacent Properties
Dear Onsite Services Engineer:
The owner of Lot 3, Gold Pan Estates Subdivision intends to construct a new three-
bedroom home on the lot to serve as a parsonage for the Saint Tikhon Russian
Orthedox Church. We are therefore requesting a permit be issued for the construction
of a new well and septic system to accommodate the home. The attached Site Plan and
backup documentation identify the location and configuration of the proposed well and
septic system along with the alternate site. Also identified on the plans are the existing
wells and septic systems on surrounding lots. No conflicts exist between the proposed
septic system and well or septic systems and wells on adjacent lots. Drainage arrows
are shown on the site plan showing the grade and direction of flow on the lot. The
drainage pattern will not be changed as a result of this project.
A test hole was placed on the lot in the area of the absorption trench and alternate site.
The log indicates well graded to silty gravel (GW/GM) in the zone specified for the
absorption trench. The percolation rate of the soil was determined to be 1.4 minutes
per inch. No groundwater was found during the placement of the test hole and none
was noted during the monitoring period. An application rate of 1.2 gallons per day per
square foot was used in the design of the absorption system. We are proposing to
place a new 1,000-gallon septic tank and a 38' long by 5' wide by 4' effective depth
absorption trench to treat and dispose of the effluent generated in the house. The
elevation of the distribution line in the absorption trench will be 4' below the surface and
the total depth will be 8'. A minimum of 3' of fill or 2" of insulation and 2' of fill will be
placed over the absorption trench and 4' over the septic tank.
The ground surface on the lot in the area of the septic system slopes to the southwest.
The new trench will be constructed parallel with the contours of the slope as much as
Lot 3, Gold Pan Estates Subdivision
July 7, 2013
Page Two
possible in conformance with Municipal requirements. The new septic system will be
constructed a minimum of 100' from all wells and any surface water and 10' the
proposed and existing water services in the area.
If the system is constructed in accordance with our design the following statements
apply:
The system, if constructed as designed, will have no adverse impact on the wells
in the area or those to be constructed in the future.
The system, if constructed as designed, will have no adverse impact on existing
septic systems in the area or those to be constructed in the future.
The system, if constructed as designed, will have no adverse impact'on reserve
space, either surface or subsurface, on any lots located in the area.
The system, if constructed as designed, will have no adverse impact on drainage
patterns in the area. The current drainage pattern will be maintained.
Sincerely,
Michael E. Anderson, P.E.
Attachments
/// GOLD PAN ESTATES SUBDIVISION
,' LOT 5 ~
~ LOT IA
.... ..... ;::?///11 )
~--2--~ the Deve~men~'of
..----- / /--~--, ~_~._~-- ~ ,,,
... ~ 7~~--~IY ,,;
~ ~ E lJ2 LOT 241
I / 49th.
W 1/2 LOT 241 ~ .. ~* ............................. ~7;[.y?-~ '
'"'-- ''~-' "SITE PLhN '~,'~'"'~"~'~"'~"~"";'~i' -
,,,,, ~ ~, . ~o, ,,,,, ..,~~.,
LOT 3, GOLD PAN ESTATES SUBDIVISION
DESIGN FACTORS: SYSTEM REQUIREMENTS:
Three Bedroom Home 5' Wide Trench System
Perc. Rate: 1.4 Min./Inch 1,000 Gallon Septic Tank
Application Rate: 1.2 GPD/SF 4' Drainfield Rock
3 Bedrooms * 150 GPD/Bedroom ~ 450 SF Absorption Area
450 SF/1.2 GPD/SF/5 SF (Width) .5 (Red. Factor)= 37.5 LF Trench Length
THEREFORE: Construct a 38' Long x 5' Wide x 4' Effective Depth Absorption Trench.
Flow Line Elevation in Trench to be 4' Below Original Ground Surface. Total Depth to be
8' Below Existing Ground. Provide 3' Cover Over Absorption Trench and 4' Cover Over
Septic Tank.
4~
..........~eotextile Fabric
% 4" Perforated
PVC (Holes Down)
Drainfield Rock
TYPICAL 5' WIDE TRENCH SECTION
........(NO SCALE) ,~.~.-~ OF'~
NOTE: Grade Area Over Trench to Drain Away· 1 4, ? ~i
· · , · j -" 49th ~
Minimum 6 Separabon From Bedrock· ¢%-;..';¢....,.,,.....,, ........... .~.,,t-.',~
Minimum 4' S,eparation From Groundwater. ~ ~
Minimum 100 Separation From Private Wells in the Area· ~'~'~'~";,;;~'~'s"o'~'"7~'~ '
Minimum 200' Separation From Class A Well on Adjacent Lot. -~?..¢'~',... No. c~-,~
Minimum 100' Separation From Surface Water or Streams
· ,.~:~..,~. ~,,,-~ ~.'~ .,_~,.~
4700
MUNICIPALITY Of ANCHORAGE
DEVELOPMENT SERVICES DEPARtMENt
BRAGAW STREET ANCHORAGE, AK 99519-6650
DEPTH
(feet)
1
2--
3
4
5
6
7--
8--
9--
11
20-
SOILS LOG - PERCOLATION TEST ]
LEGAL DESCRIPTION: Gold Pan Estates, Lot 3
PERFORMED FOR: Saint Tikhon Russian Orthodox Church
DATE: 6/27/13 PROJECT No.:
PARCEL ID#: TECHNICIAN: JB
I TESTHOLE 1 I
OB/OG
WAS GROUND WATER ENCOUNTERED? __
IF YES ~ WHAT DEPTH9.__
DEPTH OF WATER AFTER MONITORING:
GW/GH
SLOPE
No
None
D^TEOFMOmrORING:7/6/2013
B.O.H,
SITE PLAN
SEE SITE PLAN
DEPTH TO
DATE READING GROSS TIME NET TIME WATER NET DROP
(MINUTES) (MINUTES) (INCHES) (INCHES)
~/27/13 TEST HOLE PRESOAKED PRIOR TO TESTING:
1 3:10 10 1.25"/8.s0" 7.25"
2 3:21 10 1.13"/8.38" 7.25"
3 3:32 10 1.25"/8.38" 7.13"
4 3:43 10 1.06"/8.19' 7.13"
5 3:54 10 1.1Y'/8.25' 7.13"
6 4:05 10 1.25"/8.38' 7.13"
PERCOLATION RATE: 1.4
TEST RUN BETWEEN: 4
__(MIN/INCH) PERC. HOLE DIA. 10 (INCHES)
FT. and 5 FT.
COMMENTS: TEST HOLE PRE SOAKED PRIOR TO TEST,
TEST PERFORMED BY ANDERSON ENGINEERING. 1, MICHAEL E. ANDERSON CERTIFY THAT
THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPLE GUIDELINES IN EFFECT ON THIS
DATE: 7/6/13