On-Site Water & Wastewater System Permit
OSP131056
05106285000
WellSeptic
MUNICIPALITY OF ANCHORAGE
Development Services Department
On-Site Water & Wastewater Program
4700 Elmore Road, PO Box 196650
Anchorage, AK 99519-6650
Telephone: (907) 343-7904
Permit Effective Dates: August 29, 2013 to August 29, 2014
Design Engineer: GARNESS ENGINEERING GROUP LTD
Subdivision: EKLUTNA HEIGHTS
Site Legal Address: EKLUTNA HEIGHTS BLK 1 LT 10A ~;,,, ~,~,w~,?j G:1461
Owner/Address: EMMI JOHN E
PO BOX 672049 CHUGIAK AK 995672049
Site Mailing Address: 21636 SETTLERS DR, Chugiak
Lot Size in Sq Ft: 24873
Total Bedrooms: 4
~artment
This permit is for the construction of:
Y Disposal Field Y Septic Tank N Holding Tank N Privy Y Private Well N Water Storage
All construction must be in accordance with: 1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater
Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80).
3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services
Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either:
A. Open and Close on the same day.
B. Covered, sealed, and heated to prevent freezing.
Date:
Date:
MUNICIPALITY OF ANCHORAGE
Community Development Department
Development Services
On-Site Water & Wastewater Program
Phone: 907-343-7904
Fax: 907- 343-7997
Mayor Dan Sullivan
On-Site Sewer/Well Permit Application
For A Single Family Dwelling
Pamel I.D.051 "OG -
Property owner(s) JOHN EMMI Day phone 229-7135
Mailing address 21650 GRAYBILL STREET *CHUGIAK, AK 99567
Site address NHN SONGBIRD DRIVE *CHUGIAK, AK 99567
Legaldescription (Sub'd, Block& Lot) EKLUTNA HEIGHTS; BLOCK 1, LOT I OA
Legal description (Township, Section & Range)
Lot Size Sq. Ft. Number of Bedrooms
APPLICATION IS FOR:
( [~1 that apply)
Absorption Field []
Septic Tank []
Holding Tank []
Privy []
Private Well []
Water Storage []
APPLICATION IS AN:
Initial []
Upgrade []
Renewal []
TYPE OF DEWELLING:
Single Family (SF) []
(w/wo ADU)
Duplex (D) []
Multiple Dwellings []
(SF and/or D)
THIS APPLICATION INCLUDES A VARIANCE/WAIVER REQUEST FOR:
N/A Distance: -
I certify that the above information is correct. I further certify that this is in accordance with
applicable Municipal codes.
GARNESS ENGINEERING GROUP~ Ll.d.
(Signature of property owner or authorized agent)
Permit/Rush Fees:
Date of Payment:
Receipt Number:
Permit No.
Waiver Fees:
Date of Payment:
Receipt Number:
Waiver No.
(Rev. 0~/11)
GARNESS ENGINEERING GROUP, Ltd.
CONSULTANTS & GENERAL CONTRACTORS
March 6, 2013
Municipality of Anchorage
Development Service Department
On-Site Water & Wastewater Program
4700 Elmore Rd.
P.O. Box 196650,
Anchorage, Ak 99519-6650
(907) 343-7904
Ref: Proposed Initial Septic System & Private Well for Eklutna Heights Subdivision;
Block 1, Lot 10A (West Portion)
To whom it may concern:
The subject lot is currently vacant and has no water or sewer service. The owner is planning to
build a four (4) bedroom duplex on the property that will be served by a septic system and well.
We are proposing that a 1250 gallon septic tank and a deep trench type drainfield be installed.
A test hole was excavated on the property. The drainfield is designed around the 30 foot radius
of this test hole. We are also proposing to have a well drilled on-site to serve the proposed
duplex. Attached is a site plan showing neighboring lots and separation distances from the
proposed well. All necessary waivers have been approved by ADEC (see attached). Comments
regarding the design are summarized as follows: We are unaware of any adverse impacts that
the well and septic would have on any neighboring wells or septic systems.
'1. SOILS: See the attached logs which show the soil classifications, groundwater monitoring,
and the percolation test results.
2. DRAINFIELD DESIGN: See attached design drawing for drainfield specifications.
3. SURFACE WATERS: There are no surface waters within 100 feet of the proposed septic
system.
4. TOPOGRAPHY: The average topography in the vicinity of the drainfield is relatively flat.
We are unaware of any adverse impacts this installation would have on adjacent wells or septic
systems. If you ave any questions, please contact us at 337-6179. Thank you for your
assistance. //
Oeffre ~. ~arh~s.~ P.E., MS.
Presk ~ '~
3701 E. Tudor Road, Suite 10l * Anchorage, AK 99507-I259
Ph: (907) 337-6179 * Fax: (907) 338-3246 * Website: www.garnessengineering.com
THE STKFE
0 ALASKA
Feb~28,201B!
M~. Jeffe~y O'a~ess, P.E.
Gsmess F.~gineodng Group, Ltd.
3701 Tudoe Road, Suite 101
Anchorage, AK 99507
File: 2100.07 Elduma Heights S/D; Block 1, Lot 10A West
PWSID: 218804
EldumaHeights Subdivision;
Waiver Approval of 100 feet: Septic System Lot 10A, Block 1, ~Itluma Heights S/D to
Class C well onLot llA, Block 1, Eldutna Heights Subdivision.
Waiver Approval of 120 feet: Septic System Lot 10A, Block 1, Elduma Heights S/D to
Class C well on Lot 9A, Block 1, Ekluma Heights Subdivision.
Dea~ M~. Gsmess,
On December 19, 2012 this office received two separation distance waiver requests associated with the
proposed septic system located on Lot 10A West, Block 1, Eldutna Heights Subdivieion. The construction of
a new septic system on Lot 10A (serving a duplex) cannot be completed without encroaching on the t~quired
separation distances of two Class C well~ located on adjacent lots. Information was provided on the
adjoining eZlo~s C wells to allow the assessment of the potential risk posed by the septic system on Lot 10A.
Howevex, insufficient information on lot development on LOt 9A or Lot llA was provided to support the
approval of any other aspects, including any other needed Waivers, a~sociated with these wells. Nor was may
approval associated with these adjoining Class C wells requested.
Waiver Condition~ and Determination
Based on an evaluation of the available information, the potential for contamination due to the lesser
sepax'afion distance between the Class C wells and the septic system does not appeax to be significant.
Separation distance waivers between the wells and septic system on Lot 10A axe summarized below:
~l/aiverl:-Class C Well oa Lo~lock-l-Etduhi~ lleights
Septic system on LOt 10A, Block 1 Eklutoa Heights Subdivision to Class C well Lot 9A, Block 1 Ekluma
Heights Subdivision (serving a six bedroom mplex)
The separation distance reqmred by regulation is 150 feet. The sepaxafion distance t'equested and approved is
100 feet.
1. Although there was no indication of well grouting on the well log submitted for Lot 9A, the well
shows a depth of 155 feet and a confining layer of silt and clay that may mitigate potential
contamination.
2. Lab results on water taken from the well on Lot 9A show nitrates present, but below the MCL level
0.68 mg/L present, a maximum of 10 mg/L allowed).
1B0205EklutnaHeightsSOBlock1[0t10AWest218804FO.doc Page 1 of 2
blt. Jeffery 6amess, P.B.
Februszy 28, 201:5
3. Lab ~esults indicated an absence ofbactetia in the water sample taken on this lot.
4. The proposed septic system on Lot 10A ~h~!l be dedgncd and constructed withi~ State Standa~ls.
5. Due to development density with{n the subdivision, there a~e few options for the placement of this
septic system.
Waive! 2: Class C Well on Lot 1lA, Block 1 Eklutna Heiffhts Subdivision
Sep.~c system on I~t 10A, B!ock 1 !~luma Heigh~ Subdivision m Class C well located on Loc !lA, Block I
Bklutn~ Heights Subdivision (serving a five bedroom ~plex).
Thc sept!ion dis~,~uce ~equi~cd by ~egul~tion is 150 feet. The sedation distance requested and approved is
120 feet.
1. Although there was no indication of well ~oudug on the well log submkted for Lot 11A, the welt log
submitted shows a depth of 75 feet and a con ~.i,$ loye~ of silt md clay tl~t may mitigate potential
contamination.
2. Lab msutts on wate£ ~l~en ~'om the well on Lot llA show nitrates p~esent, but significantly below thc
MCL level (0.794 mg/L p~esent, a m~ximum of 10 mg/L allowed).
.~. Lab ~esultMndicst~senee of-b~cte~ i~the~ate~ s~mpte~mken~this lot.
Thc ~oposcd septic system on_Lgt 10A shall be designed and constructed wi~jn Sta___te Scandals.
5. Due to development density within the subdivision, thexe s~e few opdons for the placement of this
septic system.
Ap~ov~l
The pm'pose of this le~ is to ~*~nt the requested separation distanen wgive~s between the l~Oposed
septic system on Lot 10A and thc two existing Class '~C" wells on Lot 9A and 11A. This walvef
appmvalis for the sepa~a~on distances associated with proposed septic system on Lot 10A only, and
in no w~y constitutes approval ofeny other separation distances associated with these lots.
This approval does not imply the g~uting of additional authotizations, not obligate any federal, state, of local
regulsto~ body to g£ant rcqui~ed antho~izations. The w~e.~ for the lesse~ seps~a~on distance is not au
approve! of orni,sions o~ oversights by ~ office o~ noncompliance with any applicable regulation. The
Deps_,tment's approval does not gtmmntee ces~ccmess of tlae functional design o~ wa!vel the own~'s
responsib'tllty fo! continued comp!lance with State rcgu~fions.
Any person who clisag~ecs with this decision m~y ~ecluesc an adjudicatory hem:iug in sccort~,~e with 18 AAC
15.195- 18 AAC 15.540 or ~u infomul re'view by the Division I)kecto~ in sccoml~uce with 18 AAC 15. I85.
Informal ~eview ~equests muse be delivered to the acting Division Di~eetor, Wlsine Busse Yloyd, 555 Co~dov~
St, Anchorage, A~sl~ 99501, within, 15 days of receipt of ~ decision. Adjudic~co~ hesdng ~equests must
be delivered co thc Commissione~ of'the Depazl-,ent of Envit~nmental Conservation, ?~r0r H~ig, 410
wi~loughb~a~wn~ue~`S`u~tc.~*~J~teau~A]s~kaj~8`~j~-within~:~is-decisi~. If s he~,~gis~uot
~cluested within ~0 days~ the ~ight to appeal is waived. Mo~ce info~mation on the Depsxtmcnt's ~dmini~mdve
appeals process can be found at thc following website:
htt?. :/ /www.dec.state.ak.us/commish/ReviewC, uidmuce.htm.
If you have any questions fcgs~ting this plan review please do not hesitate to contact me at 269-762~.
Sincerely,
Bnvimnmental Program Technician, DEC
130205EklutnaHeightsSDBIocklLot10AWest218804FO. doc Pase 2 of 2
I , ,~00 I EKLUTNA HE GHTS; /
I ~O~ ] BLOCK 1, LOT 8A /
J ~ ~KLUT~A ~S~ / ~ ~ /
I ~ V) '~E~6"E / ~- / ~ '
~o~o,~ .,~ L ~-J- -~-'~, ~ / I
~ [ ~ , ~ PROPOSED
/
~ ~ ' I ? 15o' w~ ~D~u~ ~
I ~ I ~ .,~ c~ss c WELL . / / /
~ ~ ~N ~.~c~s "c'/ ~ / //
',¢1 '~ ~ / / / //
~ I '~7~==---- ,' / //
, o~. ~!/ .,' I I~ ......
DOLLY AVENUE / } ,'f~ /
/ / / /.-,oo ~ ,
CONSULTAN~ & GENE~L CONT~CTORS I ........
PREPARED FOR: PHONE NUMBB: PAGE NUMBER: ~ ~ ' "~ .............. :''"~'j
SITE P~N FOR PEOPOSD WELL AND SEPTIC SYSTEM 6/13/2012
-- /1, ~ A C J_ % /--/~m'ROPOSED DRAINI~ELD
RESE~E ~]ITE~/ m-- ,,THai I .~ ~10' ~ ~;PROPOS[D 12~ GALLON ~.
/ I / ;.-~;,'"-,." ~ ...... ~1 I . 'x
~ ~*~,o /x'~' ' ~ ~/ /
/
/ v/
DESIGN CRITERIA:
NUMBER OF BEDROOMS: ~ TOTAL (DUPLEX) ~ ~~EXISTING C~SS "C" WELL
~LLONS PER DAY (GPD): ~0 / ~ ~ / SERVING 5 BEDROOM TRIP~X
.~.co~o. ~/~: ~.~ ~ / /
DRAINFIELD DESIGN: k ~// ~ / /
~c~u~ s~.~.: ~o ', ~ / I / '~ /
TO OBTAIN A CO~ OF THE L~ER -J', '
WITH THIS INSTA~TION, ~E ENGINEER, ¢. ~ ~ % ~ ~ /
GARNESS ENGINEERING GROUP, Ltd. ~%::~,~) ~ '",%~,
JOHN EMMI 229-7135 2 OF 3 [~ ~ ~, ¢e~e~ rness.:
CE 7 53
DESIGN OF PROPOSED WELL AND SEPTIC SYSTEM 6/13/2012
(Rev. 01105)
~ WEST PROPER]Y UNE
10+ FEET
RESERVE s~e - lo+ PEET
~ F ............... 1 2.5 FEET
25 RET L_____ ] ----
TH~
PTIC TANK
FCO
DESIGN CRITERIA: , ~L~ F~.~c
NUMBER OF BEDROOMS: 4 TOTAL (DUPLEX)
GALLONS PER DAY (GPD): ~0
PERCO~ON RATE/S: 2,35
MINIMUM D~NFIELD SQ.~.: 500
DRAINFIELD DESIGN:
JOHN EMMI J 229-71~5 ~ OF ~ k~ '.pf~ '~ Akga'ness.'
DETAIL OF SEPTIC SYSTEM UPGRADE 6/13/2012
(P. ev. O~/OS)
ISOIL LO(;- PERCOLATIONTESTI -' -- L ~ ~J~J~
DEPTH ~ __ __ '~,'~',~ ....... c,\
Ge.t) ORGANICS HOLE
~,~1~3; SOIL C~SSIFICATIONS
;'~,:;'~:-%, GC OL
GP TO SP i sc SEE AUACHED SITE P~N
;~,.;;~:,.., W/ SOME
,~,.3:.'., SILT LENSES DEPTH TO
7--.??~?., t, THROUGHOUT DATE
~,.;,,:..., GROUNDWATER
8 -- .:~?~;?.. ~ DRY 6/~/2012
? ~?~ ,- ~ DRY 6/5/2012
9 1 :?~:.~,, ~ DRY 6/13/2012
?~J?"~ CLOCK NET TIME WATER LEVEL NET DROP
;~ '~' ' DATE READING
:~?~.- ~ TIME (MINUTES) READING (INCHES)
~",~ · · 6/5/2012 1 11 :~3 - -
12--~
,~ '.:,S~ 2 11:53 10 1-3/~" ~- 1/~"
, ,,,:~;.*; 3 11:53 6" -
13~
' "~'4¢; 4 12:03 10 1 -3/4" 4-1/4"
SP TO GP 6"
1~-- · ee k":~' 5 12:03 - -
· ,e:,?~ (HORE SAND
~;eFf~'~' THEN GRAVEL) 6 12:13 ~0 1-3/~" 4-1/~"
%"e:~;~;~:' SOHE SILT LENSES
15- ee.?..?E 6"
', 'e:~::?~ 7 12:13 - -
16 ~ ~ 8 12:23 10 1-3/4" 4-1/4"
B.O.H.
9 12:23 - 6,' _
17~ 10 12:33 10 1-3/~" ~- 1/~"
11 12:33 - 6" _
18 -- 12 12:43 10 1 --3/4"
PERCOLATION RATE 2.35 (H~N./INCH) PERC. HOLE DIA. 6 (INCHES)
19-
TEST RUN BETWEEN 4 FT. AND 5 FT,
20-- ~ A FOUR HOUR PRESOAK WAS PERFORNED: ~ YES ~ NO
BOILS LOGGED BY: JODY MAUS PERCOLATION TEST PERFORHED BY: JODY MAUS
COMMENTS: PERCO~TION RESULTS ARE WITHIN 1/16TH OF AN INCH.
WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE:
DEPTH TO
GROUNDWATER DATE
DRY 6/4/2012
DRY 6/5/2012
DRY 6/13/2012