HomeMy WebLinkAboutEKLUTNA HEIGHTS BLK 1 LT 10A W PTN REMEklutne Heights Block ! Lot I OA W of Hwy #020-491-08 Permit Number: Tax Code Number: Work Type: On-Site Water & Wastewater System Permit OSP131056 05106285000 WellSeptic MUNICIPALITY OF ANCHORAGE Development Services Department On-Site Water & Wastewater Program 4700 Elmore Road, PO Box 196650 Anchorage, AK 99519-6650 Telephone: (907) 343-7904 Permit Effective Dates: August 29, 2013 to August 29, 2014 Design Engineer: GARNESS ENGINEERING GROUP LTD Subdivision: EKLUTNA HEIGHTS Site Legal Address: EKLUTNA HEIGHTS BLK 1 LT 10A ~;,,, ~,~,w~,?j G:1461 Owner/Address: EMMI JOHN E PO BOX 672049 CHUGIAK AK 995672049 Site Mailing Address: 21636 SETTLERS DR, Chugiak Lot Size in Sq Ft: 24873 Total Bedrooms: 4 ~artment This permit is for the construction of: Y Disposal Field Y Septic Tank N Holding Tank N Privy Y Private Well N Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80). 3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either: A. Open and Close on the same day. B. Covered, sealed, and heated to prevent freezing. Date: Date: MUNICIPALITY OF ANCHORAGE Community Development Department Development Services On-Site Water & Wastewater Program Phone: 907-343-7904 Fax: 907- 343-7997 Mayor Dan Sullivan On-Site Sewer/Well Permit Application For A Single Family Dwelling Pamel I.D.051 "OG - Property owner(s) JOHN EMMI Day phone 229-7135 Mailing address 21650 GRAYBILL STREET *CHUGIAK, AK 99567 Site address NHN SONGBIRD DRIVE *CHUGIAK, AK 99567 Legaldescription (Sub'd, Block& Lot) EKLUTNA HEIGHTS; BLOCK 1, LOT I OA Legal description (Township, Section & Range) Lot Size Sq. Ft. Number of Bedrooms APPLICATION IS FOR: ( [~1 that apply) Absorption Field [] Septic Tank [] Holding Tank [] Privy [] Private Well [] Water Storage [] APPLICATION IS AN: Initial [] Upgrade [] Renewal [] TYPE OF DEWELLING: Single Family (SF) [] (w/wo ADU) Duplex (D) [] Multiple Dwellings [] (SF and/or D) THIS APPLICATION INCLUDES A VARIANCE/WAIVER REQUEST FOR: N/A Distance: - I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal codes. GARNESS ENGINEERING GROUP~ Ll.d. (Signature of property owner or authorized agent) Permit/Rush Fees: Date of Payment: Receipt Number: Permit No. Waiver Fees: Date of Payment: Receipt Number: Waiver No. (Rev. 0~/11) GARNESS ENGINEERING GROUP, Ltd. CONSULTANTS & GENERAL CONTRACTORS March 6, 2013 Municipality of Anchorage Development Service Department On-Site Water & Wastewater Program 4700 Elmore Rd. P.O. Box 196650, Anchorage, Ak 99519-6650 (907) 343-7904 Ref: Proposed Initial Septic System & Private Well for Eklutna Heights Subdivision; Block 1, Lot 10A (West Portion) To whom it may concern: The subject lot is currently vacant and has no water or sewer service. The owner is planning to build a four (4) bedroom duplex on the property that will be served by a septic system and well. We are proposing that a 1250 gallon septic tank and a deep trench type drainfield be installed. A test hole was excavated on the property. The drainfield is designed around the 30 foot radius of this test hole. We are also proposing to have a well drilled on-site to serve the proposed duplex. Attached is a site plan showing neighboring lots and separation distances from the proposed well. All necessary waivers have been approved by ADEC (see attached). Comments regarding the design are summarized as follows: We are unaware of any adverse impacts that the well and septic would have on any neighboring wells or septic systems. '1. SOILS: See the attached logs which show the soil classifications, groundwater monitoring, and the percolation test results. 2. DRAINFIELD DESIGN: See attached design drawing for drainfield specifications. 3. SURFACE WATERS: There are no surface waters within 100 feet of the proposed septic system. 4. TOPOGRAPHY: The average topography in the vicinity of the drainfield is relatively flat. We are unaware of any adverse impacts this installation would have on adjacent wells or septic systems. If you ave any questions, please contact us at 337-6179. Thank you for your assistance. // Oeffre ~. ~arh~s.~ P.E., MS. Presk ~ '~ 3701 E. Tudor Road, Suite 10l * Anchorage, AK 99507-I259 Ph: (907) 337-6179 * Fax: (907) 338-3246 * Website: www.garnessengineering.com THE STKFE 0 ALASKA Feb~28,201B! M~. Jeffe~y O'a~ess, P.E. Gsmess F.~gineodng Group, Ltd. 3701 Tudoe Road, Suite 101 Anchorage, AK 99507 File: 2100.07 Elduma Heights S/D; Block 1, Lot 10A West PWSID: 218804 EldumaHeights Subdivision; Waiver Approval of 100 feet: Septic System Lot 10A, Block 1, ~Itluma Heights S/D to Class C well onLot llA, Block 1, Eldutna Heights Subdivision. Waiver Approval of 120 feet: Septic System Lot 10A, Block 1, Elduma Heights S/D to Class C well on Lot 9A, Block 1, Ekluma Heights Subdivision. Dea~ M~. Gsmess, On December 19, 2012 this office received two separation distance waiver requests associated with the proposed septic system located on Lot 10A West, Block 1, Eldutna Heights Subdivieion. The construction of a new septic system on Lot 10A (serving a duplex) cannot be completed without encroaching on the t~quired separation distances of two Class C well~ located on adjacent lots. Information was provided on the adjoining eZlo~s C wells to allow the assessment of the potential risk posed by the septic system on Lot 10A. Howevex, insufficient information on lot development on LOt 9A or Lot llA was provided to support the approval of any other aspects, including any other needed Waivers, a~sociated with these wells. Nor was may approval associated with these adjoining Class C wells requested. Waiver Condition~ and Determination Based on an evaluation of the available information, the potential for contamination due to the lesser sepax'afion distance between the Class C wells and the septic system does not appeax to be significant. Separation distance waivers between the wells and septic system on Lot 10A axe summarized below: ~l/aiverl:-Class C Well oa Lo~lock-l-Etduhi~ lleights Septic system on LOt 10A, Block 1 Eklutoa Heights Subdivision to Class C well Lot 9A, Block 1 Ekluma Heights Subdivision (serving a six bedroom mplex) The separation distance reqmred by regulation is 150 feet. The sepaxafion distance t'equested and approved is 100 feet. 1. Although there was no indication of well grouting on the well log submitted for Lot 9A, the well shows a depth of 155 feet and a confining layer of silt and clay that may mitigate potential contamination. 2. Lab results on water taken from the well on Lot 9A show nitrates present, but below the MCL level 0.68 mg/L present, a maximum of 10 mg/L allowed). 1B0205EklutnaHeightsSOBlock1[0t10AWest218804FO.doc Page 1 of 2 blt. Jeffery 6amess, P.B. Februszy 28, 201:5 3. Lab ~esults indicated an absence ofbactetia in the water sample taken on this lot. 4. The proposed septic system on Lot 10A ~h~!l be dedgncd and constructed withi~ State Standa~ls. 5. Due to development density with{n the subdivision, there a~e few options for the placement of this septic system. Waive! 2: Class C Well on Lot 1lA, Block 1 Eklutna Heiffhts Subdivision Sep.~c system on I~t 10A, B!ock 1 !~luma Heigh~ Subdivision m Class C well located on Loc !lA, Block I Bklutn~ Heights Subdivision (serving a five bedroom ~plex). Thc sept!ion dis~,~uce ~equi~cd by ~egul~tion is 150 feet. The sedation distance requested and approved is 120 feet. 1. Although there was no indication of well ~oudug on the well log submkted for Lot 11A, the welt log submitted shows a depth of 75 feet and a con ~.i,$ loye~ of silt md clay tl~t may mitigate potential contamination. 2. Lab msutts on wate£ ~l~en ~'om the well on Lot llA show nitrates p~esent, but significantly below thc MCL level (0.794 mg/L p~esent, a m~ximum of 10 mg/L allowed). .~. Lab ~esultMndicst~senee of-b~cte~ i~the~ate~ s~mpte~mken~this lot. Thc ~oposcd septic system on_Lgt 10A shall be designed and constructed wi~jn Sta___te Scandals. 5. Due to development density within the subdivision, thexe s~e few opdons for the placement of this septic system. Ap~ov~l The pm'pose of this le~ is to ~*~nt the requested separation distanen wgive~s between the l~Oposed septic system on Lot 10A and thc two existing Class '~C" wells on Lot 9A and 11A. This walvef appmvalis for the sepa~a~on distances associated with proposed septic system on Lot 10A only, and in no w~y constitutes approval ofeny other separation distances associated with these lots. This approval does not imply the g~uting of additional authotizations, not obligate any federal, state, of local regulsto~ body to g£ant rcqui~ed antho~izations. The w~e.~ for the lesse~ seps~a~on distance is not au approve! of orni,sions o~ oversights by ~ office o~ noncompliance with any applicable regulation. The Deps_,tment's approval does not gtmmntee ces~ccmess of tlae functional design o~ wa!vel the own~'s responsib'tllty fo! continued comp!lance with State rcgu~fions. Any person who clisag~ecs with this decision m~y ~ecluesc an adjudicatory hem:iug in sccort~,~e with 18 AAC 15.195- 18 AAC 15.540 or ~u infomul re'view by the Division I)kecto~ in sccoml~uce with 18 AAC 15. I85. Informal ~eview ~equests muse be delivered to the acting Division Di~eetor, Wlsine Busse Yloyd, 555 Co~dov~ St, Anchorage, A~sl~ 99501, within, 15 days of receipt of ~ decision. Adjudic~co~ hesdng ~equests must be delivered co thc Commissione~ of'the Depazl-,ent of Envit~nmental Conservation, ?~r0r H~ig, 410 wi~loughb~a~wn~ue~`S`u~tc.~*~J~teau~A]s~kaj~8`~j~-within~:~is-decisi~. If s he~,~gis~uot ~cluested within ~0 days~ the ~ight to appeal is waived. Mo~ce info~mation on the Depsxtmcnt's ~dmini~mdve appeals process can be found at thc following website: htt?. :/ /www.dec.state.ak.us/commish/ReviewC, uidmuce.htm. If you have any questions fcgs~ting this plan review please do not hesitate to contact me at 269-762~. Sincerely, Bnvimnmental Program Technician, DEC 130205EklutnaHeightsSDBIocklLot10AWest218804FO. doc Pase 2 of 2 I , ,~00 I EKLUTNA HE GHTS; / I ~O~ ] BLOCK 1, LOT 8A / J ~ ~KLUT~A ~S~ / ~ ~ / I ~ V) '~E~6"E / ~- / ~ ' ~o~o,~ .,~ L ~-J- -~-'~, ~ / I ~ [ ~ , ~ PROPOSED / ~ ~ ' I ? 15o' w~ ~D~u~ ~ I ~ I ~ .,~ c~ss c WELL . / / / ~ ~ ~N ~.~c~s "c'/ ~ / // ',¢1 '~ ~ / / / // ~ I '~7~==---- ,' / // , o~. ~!/ .,' I I~ ...... DOLLY AVENUE / } ,'f~ / / / / /.-,oo ~ , CONSULTAN~ & GENE~L CONT~CTORS I ........ PREPARED FOR: PHONE NUMBB: PAGE NUMBER: ~ ~ ' "~ .............. :''"~'j SITE P~N FOR PEOPOSD WELL AND SEPTIC SYSTEM 6/13/2012 -- /1, ~ A C J_ % /--/~m'ROPOSED DRAINI~ELD RESE~E ~]ITE~/ m-- ,,THai I .~ ~10' ~ ~;PROPOS[D 12~ GALLON ~. / I / ;.-~;,'"-,." ~ ...... ~1 I . 'x ~ ~*~,o /x'~' ' ~ ~/ / / / v/ DESIGN CRITERIA: NUMBER OF BEDROOMS: ~ TOTAL (DUPLEX) ~ ~~EXISTING C~SS "C" WELL ~LLONS PER DAY (GPD): ~0 / ~ ~ / SERVING 5 BEDROOM TRIP~X .~.co~o. ~/~: ~.~ ~ / / DRAINFIELD DESIGN: k ~// ~ / / ~c~u~ s~.~.: ~o ', ~ / I / '~ / TO OBTAIN A CO~ OF THE L~ER -J', ' WITH THIS INSTA~TION, ~E ENGINEER, ¢. ~ ~ % ~ ~ / GARNESS ENGINEERING GROUP, Ltd. ~%::~,~) ~ '",%~, JOHN EMMI 229-7135 2 OF 3 [~ ~ ~, ¢e~e~ rness.: CE 7 53 DESIGN OF PROPOSED WELL AND SEPTIC SYSTEM 6/13/2012 (Rev. 01105) ~ WEST PROPER]Y UNE 10+ FEET RESERVE s~e - lo+ PEET ~ F ............... 1 2.5 FEET 25 RET L_____ ] ---- TH~ PTIC TANK FCO DESIGN CRITERIA: , ~L~ F~.~c NUMBER OF BEDROOMS: 4 TOTAL (DUPLEX) GALLONS PER DAY (GPD): ~0 PERCO~ON RATE/S: 2,35 MINIMUM D~NFIELD SQ.~.: 500 DRAINFIELD DESIGN: JOHN EMMI J 229-71~5 ~ OF ~ k~ '.pf~ '~ Akga'ness.' DETAIL OF SEPTIC SYSTEM UPGRADE 6/13/2012 (P. ev. O~/OS) ISOIL LO(;- PERCOLATIONTESTI -' -- L ~ ~J~J~ DEPTH ~ __ __ '~,'~',~ ....... c,\ Ge.t) ORGANICS HOLE ~,~1~3; SOIL C~SSIFICATIONS ;'~,:;'~:-%, GC OL GP TO SP i sc SEE AUACHED SITE P~N ;~,.;;~:,.., W/ SOME ,~,.3:.'., SILT LENSES DEPTH TO 7--.??~?., t, THROUGHOUT DATE ~,.;,,:..., GROUNDWATER 8 -- .:~?~;?.. ~ DRY 6/~/2012 ? ~?~ ,- ~ DRY 6/5/2012 9 1 :?~:.~,, ~ DRY 6/13/2012 ?~J?"~ CLOCK NET TIME WATER LEVEL NET DROP ;~ '~' ' DATE READING :~?~.- ~ TIME (MINUTES) READING (INCHES) ~",~ · · 6/5/2012 1 11 :~3 - - 12--~ ,~ '.:,S~ 2 11:53 10 1-3/~" ~- 1/~" , ,,,:~;.*; 3 11:53 6" - 13~ ' "~'4¢; 4 12:03 10 1 -3/4" 4-1/4" SP TO GP 6" 1~-- · ee k":~' 5 12:03 - - · ,e:,?~ (HORE SAND ~;eFf~'~' THEN GRAVEL) 6 12:13 ~0 1-3/~" 4-1/~" %"e:~;~;~:' SOHE SILT LENSES 15- ee.?..?E 6" ', 'e:~::?~ 7 12:13 - - 16 ~ ~ 8 12:23 10 1-3/4" 4-1/4" B.O.H. 9 12:23 - 6,' _ 17~ 10 12:33 10 1-3/~" ~- 1/~" 11 12:33 - 6" _ 18 -- 12 12:43 10 1 --3/4" PERCOLATION RATE 2.35 (H~N./INCH) PERC. HOLE DIA. 6 (INCHES) 19- TEST RUN BETWEEN 4 FT. AND 5 FT, 20-- ~ A FOUR HOUR PRESOAK WAS PERFORNED: ~ YES ~ NO BOILS LOGGED BY: JODY MAUS PERCOLATION TEST PERFORHED BY: JODY MAUS COMMENTS: PERCO~TION RESULTS ARE WITHIN 1/16TH OF AN INCH. WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE: DEPTH TO GROUNDWATER DATE DRY 6/4/2012 DRY 6/5/2012 DRY 6/13/2012