HomeMy WebLinkAboutRAVEN MOUNTAIN ESTATES #1 BLK 3 LT 4Raven Mountain
Estates #1
Block 3
Lot 4
#076 - 031 - 20
On-Site Water System Permit
MUNICIPALITY OF ANCHORAGE
Development Services Department
On-Site Water & Wastewater Program
4700 Elmore Road, PO Box 196650
Anchorage, AK 99519-6650
Telephone: (907) 343-7904
Permit Number: OSP131341
Tax Code Number: 07603120000
Work Type; Well
Permit Effective Dates: September 18, 2013 to September 18, 2014
Design Engineer: ANDERSON ENGINEERING
Subdivision: RAVEN MOUNTAIN ESTATES #1
Site LegalAddress; RAVEN MOUNTAIN ESTATES #1 BLK 3 LT 4 G:4018
Owner/Address: NORWOOD STEVE
PO BOX 993 GIRDWOOD AK 995870993
Site Mailing Address: 220 GOLD CLAIM DR, Girdwood
Lot Size in Sq Ft; 33680
Total Bedrooms: 2
This permit is for the construction of:
N Disposal Field N Septic Tank N Holding Tank N Privy Y Private Well N Water Storage
All construction must be in accordance with: 1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater
Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80).
3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services
Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either:
A. Open and Close on the same day.
B. Covered, sealed, and heated to prevent freezing.
Date:
MUNICIPALITY OF ANCHORAGE
Community Development Department
Development Services Division
On-Site Water & Wastewater Program
Phone: 907-343-7904
Fax: 907-343-7997
ON-SITE SEWER/WELL PERMIT APPLICATION
Property owner(s)
Mailing address
Site address r~o~O
Parcel I.D. 0¢~'- 03l - 20
Legal description (Sub'd., Block & Lot)
Legal description (Township, Range & Section)
LotSize ~, ~0 Sq. Ft. Number of Bedrooms
Day phone
APPLICATION IS FOR: APPLICATION IS AN:
((~ all that apply)
Absorption Field [] Initial [~
Septic Tank [] Upgrade []
Holding Tank [] Renewal ~
Privy []
Private Well 'E~
Water storage []
TYPE OF DWELLING:
Single Family (SF)
(w/wo ADU)
Duplex (D)
Multiple Dwellings (SF and/or D)
THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR:
Distance:
I certify that the above information is correct. I further certify that this is in accordance with
applicable Municipal Codes.
(Signature of property owner or adthorized agent)
Permit/Rush Fees:
Date of Payment:
Receipt Number:
Permit No.
Waiver Fees:
Date of Payment:
Receipt Number:
Waiver No.
Permit App_;* :, ', 2.dc =
Municipality of Anchorage 4 =°` "°
® Development Services Department ,;
Building Safety Division �� sT.
On -Site Water and Wastewater Program, 4700 Elmore Road
P.O. Box 196650 Anchorage, AK 99507 Page of
www,cl.anchorage.ak.us (907) 343-7904
ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT
Permit Number: OSP111159 PID Number. 076-031-20
Name:
Steve Norwood Wastewater System: ❑✓ New ❑ Upgrade:
Address:
P.O. Box 993 Girdwood, AK 99587 ABSORPTION FIELD
Phone: Number of Bedrooms:
2
❑ Deep Trench q Shallow Trench 14 Bed 13 Mound Q Other.
LEGAL DESCRIPTION
Soil Rating:
Total Depth from original grade:
Bfock: Lot: Subdivision:
3 4 Raven Mtn. Est. #1
7 GPD/F?
Da th to
p pipe 1 Ort m original grade:
13.1 Ft.
Graver depth beneath pipe:
Township: Range: Section:
Ft.
Fill added above original grade:
•$ FL
Gravel Length:
0 Ft.
35 Ft.
Well: ❑ New ❑ Upgrade
Gravalwidth
Numberoflines: Distance betweengres:
Classification (Private, A, B, C): Total Depth Cased to:
Propose
15 Ft.
Total absorption area:
3 5 Ft.
I Pipe Material:
FI FL
525 Fe
ASTM D3034 PVC
Driller.
Date Drilled:
Static Water Level:
Installer.
Date installed:
Ft
PCN, Inc.
8122-2512011
Yield:
Pump Set at
Casing Height Above Ground:
GPM
Ft.
FL
TANK
SEPARATION DISTANCES
® Septic © Holding ❑ S.T.E.P' ❑ Other:
To
Septic
Absorption
Lift
Holding
ubiiclPrivata
Manufacture,
Capacity:
From
Tank
Field
Station
Tank
Sewer tine
Anchorage Tank
1,000 Gal.
welt
N/A
N/A
N/A
N/A
>25'
Material:
Siee!
NumberofCom rtmerrLs:
Numb'two rof pa
-7
surtamWater
>100'
>100,
>100'
NIA
LIFT STATION
Lot Line
>6
>10'.
>5'
N/A
Sze:
Manufacturer.
Gal.
Foundation
>5'
>10'
>5'
N/A
/V1
Pump on° level at:
Pump cif" level at:
High water alarm at:
in.
im
in.
durtain Drain
(Mone
Noted
Pump Make & Model
Electrical inspections performed by:
Remarks:
Well Not in Place as of This Date.
BENCH MARK
Location and Descriptton:
Top of Retaining Wall. West End of House.
Assumed Elevation:
100.0 Ft.
,�luiine s5t�mp
Inspections performed by: MPS Dates: 1at 8/23/2011 0t
••e •••�5����
2nd 8/24, 2812011 m �Q:�•
Arfi�,
Development Services Department Approval •�=y ; ��
* �•
Conditional Approval pate: 60 *• •••• "•�`
sN 0 woo* •s•�
i�it t
Y,�/A�a)
®Cat
}�AM+y+�
fie \fir B 4381
e.`\�
a� ed and approved by: Date: �� �tJ� j + � *'tOrisslov;o'
LOT 5
VACANT
i
Municipality of Anchorage
DEVEOPMENT SERVICES DEPARTMENT
4700 Elmore Road Anchorage, AK. 99519-6655 - 343-7904
Permit Number: OSP 111159 Page 2 of 3
PID No, 076-031-20
A [ S Existing
m 57.0' 5s.4' Well
S2 72.7' 61.4'
C4 52.7' 73.3'
C5 111.5'99.3'
M184.8' 72.6'
,~,o,.s. co.~ Block 5
x, /
\/
A
/ \
/
!
LOT /4
\
LEGEND:
CO - Cleanout % /"
SV - SepUc Vent
FCO - Foundation Cleanout ~ .'
TH - Tes( Hole
'~MT - Monitor Tube
SCALE 1 ' : 40'
Pr&ced"'X
\
/
LOT 3
VACANT
I..~.~.~
~t MIC~L ~. ANDERSON
Municipality of Anchorage
DEVEOPMENT SERVICES DEPARTMENT
4700 Elmore Road Anchorage, AK. 99519-6655 - 343-7904
On-Site Wastewater Disposal System or Well Inspection Report
Permit Number: OSP111159
Page 3 of 3
PID No. 076-031-20
Finished
/~ 96.7
1 000 Gallon ~
Sept c Tank
98.0 97.1
Finished Grade /
Odginal Ground
Geotextile Fabdc
97.9 --' · ~-- 87.1 Drainfield Rock
87.1
2' Coarse Sand
~ 81.1
8/23n 1
87.9
35' (Bed Length)
PROFILE AS-BUILT
No ScaPe
Pipe Not
!
~._~~~~~qsNT~C ............ .................. ...................... ~.... "
~ Proposed Well
Su~eying · Engineering S'~ C~TW[CAT[ON: 9ENIAC has co~md
2525 Gambell Street, Suite 200, Anchorage, Alaska 99503 ~p~ysic~lsuwcyofthis pmp~as s~o~o~is O Test Hole
Tele: (907) 563-3835 Fax: (907) 563-3817 d~w[~ ~d that ~ ~pmwm~ situated thc~coa arc
" ' wit~thcp~op~[~ess~d~o~oac~c~tscxJst ~ Fnd, 1" Gel, Pipe
~ot 4~ ~[OCE ~ ~aVCD ~OUDt~JD ~StatCS U~t EXCLUS[O~ NO~: It is ~c' o';a~ rcspo~'~b~tJty ~ Fnd. Su~ey Mom
No. ], G~tdwood. Alaska to ~ ~. ~i,~.~ or~ ~.~, co~.t~,
.......................... or ms~cti~s which do not appear on ~e mco~ed
Jaly2Z 2011 1 ~t~6~ ,sent¢c~eeiteam~com subdivision plat. NOTE: Under no c~ms~nces
l 1-5762 ~'~'j~ '~:a~H a~aS~lS :~' ~x ........ forSn°uld any dam hgeon be useathe establishing ofpmp~ lin~.f°r ~e co=~cfionor
II IIIIIIIIIII IIIIIIIII I
Permit Number:
Tax Code Number:
Work Type:
Permit Effective Dates:
Design Engineer:
Subdivision:
Site Legal Address:
Owner/Address:
Site Mailing Address:
On-Site Water & Wastewater System Permit
MUNICIPALITY OF ANCHORAGE
Development Services Department
On-Site Water & Wastewater Program
4700 Elmore Road, PO Box 196650
Anchorage, AK 99519-6650
Telephone: (907) 343-7904
OSP111159
07603120000
WellSeptic Initial
July 27, 2011 to
ANDERSON ENGINEERING
RAVEN MOUNTAIN ESTATES #1
July 26, 2012
RAVEN MOUNTAIN ESTATES #1 BLK 3 LT 4 G:4018
NORWOOD STEVE
PO BOX 993 GIRDWOOD AK 995870993
220 GOLD CLAIM DR, Girdwood
Lot Size in Sq Ft:
Total Bedrooms:
33680
2
This permit is for the construction of:
Y Disposal Field Y Septic Tank
N Holding Tank N Privy Y Private Well
N Water Storage
Ali construction must be in accordance with: 1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater
Disposal Regulations (18AAC72) and Ddnking Water Regulations (18AAC80).
3. The wastewater code requires inspections dudng the installation. The engineer must notify the Development Services
Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either:
A. Open and Close on the same day.
B. Covered, sealed, and heated to prevent freezing.
Special Provisions: 25% or steeper slopes within 50 feet of the downhill side of the drainfield shall
be removed (flattened). A cross-section shall be submitted with the final inspection report verifying
the 50 foot separation.
Special Provisions: Prior to construction; a second test hole shall be completed to verify the soils
for the alternate drainfield site. If the test results do not support the proposed alternate drainfield
design, an approved change order shall be issued prior to construction. Test results shall be
submitted with the final inspection report.
Received By: ~'~-~ ' ·
[Date:
Date: '~,//~...~,/~//
!
MUNICIPALITY OF ANCHORAGE
Community Development Department
Development Services Division
On-Site Water & Wastewater Program
Mayor Dan Sullivan
Phone: 907-343-7904
Fax: 907-343-7997
ON-SITE SEWERRVELL PERMIT APPLICATION
FOR A SINGLE FAMILY DWELLING
Parcel i.D. DT~,--
Property owner(s)
Mailing address '~.O, ~.
Day phone
Site address ~-~O ~--~O ~7.~.,~4~,4
Legal description (Sub'd., Block & Lot) ~__A~E'I,,J
Legal description (Township, Range & Section)
Lot Size ~ ~ ~O Sq. Ft. Number of Bedrooms
THIS APPLICATION IS FOR:
([~ all that apply)
Absorption Field
Septic Tank
Holding Tank
Privy
Private Well
Water Storage
THIS APPLICATION IS AN:
Initial '~
Upgrade []
Renewal []
THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR:
I certify that the above information is correct. I further certify that this application is being made
for a Single Family Dwelling and is in accordance with applicable Municipal Codes.
(Signature of property owner or authorized agent)
Permit/Rush Fees:
Date of Payment:
Receipt Number:
Permit No. 0%~0
Waiver Fees:
Date of Payment:
Receipt Number:
Waiver No.
G:\Building\On Site\Forms\Client Forms\Permit App_010411,doc (Rev. 1/11 )
ANDERSON ENGINEERING: : I
I
I
$22-7773 677~776:6 (F~)I
July 11,2011
Municipality of Anchorage
Development Services Department
On-Site Water and Wastewater Program
4700 South Bragaw Street
Anchorage, AK 99519-6650
Su~e~:
Lot 4, Block 3, Raven Mountain Estates Unit No. 1
Well and Septic System Design and Permit Application
Impacts to Adjacent Properties
Dear Onsite Services Engineer:
The owner of the subject lot intends to construct a new well and septic system to serve
the existing two-bedroom home on the property. We are therefore requesting a permit
be issued for the construction of a new well and septic system to accommodate the
home. The attached Site Plan and backup documentation identify the location and
configuration of the proposed well and septic system along with the alternate site. No
existing wells or septic systems are closer than 100' from the proposed well or septic
system. The house location is at the end of an existing road with development only to
the northeast. Drainage arrows are shown on the site plan showing the grade and
direction of flow on the lot. The drainage pattern will not be changed as a result of this
project.
The test hole placed on the lot in the area of the absorption trench and alternate site
indicated fill material to nearly 3' underlain by clean gap graded gravel below (GP). The
percolation rate of the soil was determined to be less than 1 minute per inch. No
groundwater was found during the placement of the test hole and none was noted
during the monitoring period. A 2' sand filter will be required to slow the percolation rate
of the septic effluent. An application rate of .7 gallons per day per square foot was
used in the design of the absorption system. We are proposing to place a new 1,000-
gallon septic tank and a 30' long by 15' wide absorption bed to treat and dispose of the
effluent generated in the house. The elevation of the distribution line in the absorption
trench will be 4.0' below the surface and the total depth will be 6.5' which includes the
depth of the filter sand. A minimum of 3' of fill or 2" of insulation and 2' of fill will be
placed over the absorption trench and 4' over the septic tank.
The ground surface on the lot in the area of the absorption trench slopes to the west at
Lot 4, Block 3, Raven Mountain Estates No. 1
July 11, 2011
Page Two
a grade approximating 5%. The edge of the fill is nearly 40' from the edge of the new
bed. The slope at that point is approximately 25%, but increases at approximately 50'
from the edge of the bed. The new bed will be constructed parallel with the contours of
the slope as much as possible in conformance with Municipal requirements. The new
septic system will be constructed a minimum of 100' from all wells and any surface
water and 10' from the proposed and existing water services in the area.
If the system is constructed in accordance with our design the following statements
apply:
The system, if constructed as designed, will have no adverse impact on the wells
in the area or those to be constructed in the future.
The system, if constructed as designed, will have no adverse impact on existing
septic systems in the area or those to be constructed in the future.
The system, if constructed as designed, will have no adverse impact on reserve
space, either sur[ace or subsurface, on any lots located in the area.
The system, if constructed as designed, will have no adverse impact on drainage
patterns in the area. The current drainage pattern will be maintained.
Sincerely,
Michael E. Anderson, P.E.
AEachmen~
· 49th
~=' ~'"'"'~'"'""#'""~'F~'"'~
~ ~- MICHAEL E. ANDERSON
LOT 5
VACANT
Septic
Area
¥'~,
1,009 gallon~
SeptJc~Ta n k /
4
/
/
CO
Two Bedroom
House
LEGEND: \
CO - Cleanout
SV - Septic Vent
FCO - Foundation Cleanout
TH - Test Hole
i '/~MT - Monitor Tube
"~ SITE P~N
SCALE 1" = 40'
Existing
Well
VACANT
LOT 4, BLOCK 3, RAVEN MOUNTAIN
ESTATES UNIT NO. 1
DESIGN FACTORS: SYSTEM REQUIREMENTS:
2 Bedroom Home Shallow Bed System
Pero. Rate: <1 Min./Inch 1,000 Gallon Septic Tank
Application Rate: .7 GPD/SF 2' Sand Liner
2 Bedrooms X150 SF/Bedroom/.7 GPDlSF(Application Rate) = 428.6 SF Absorption Area
428.6 SFI15 LF (Width) = 28.57 LF Bed Length
THEREFORE: Construct a 30' Long x '15' Wide Shallow Bed as Shown Below.
Place Distribution Piping at 4.0' Below Original Ground Surface, Place 2' Sand Filter
Atop GP Layer. Provide 3' Cover Over Bed and 4' Cover Over Septic Tank.
Existing Ground
3,5'
Revegetate Top of Bed
~To ~ Grade to Drain Existing Ground
Prevent
Erosion
Geotextile Fabric
O O O
Drainfield Rock ~ 4" PVC
2' Sand Liner (See Specification)
Underlying GP
2.5' 5' 5' 2.5'
NOTE:
TYPICAL BED SECTION
(NO SCALE)
Grade Area Surrounding Bed to Drain Away.
Minimum 6' Separation From Bedrock.
Minimum 4' Separation From Groundwater,
Minimum100' Separation From Wells in the Area.
Minimum 100' Separation From Surface Water or Streams.
Minimum 10' Separation From Water Service Line.
Z
m k.--
m,,~z
Z ©
0
Z
4700
MUNICIPALITY OF ANCHORAGE
DEVELOPMENT SERVICES DEPARTMENT
BRAGAW STREET ANCHORAGE, AK 99519-6650
SOILS LOG - PERCOLATION TEST ]
LEGAL DESCRIPTION:
PERFORMED FOR:
DATE: 8/25/2011
PARCEL ID#:
LOT 4, BLOCK 3, RAVEN MOUNTAIN EST. NO. I
STEVE NORWOOD
PROJECT No.:
TECHNICIAN:
D:P~ I TEST HOLE 1 [
(f~t)
1 SLOPE
2I
3
5 PEAT, ROOTS, STUMPS
OTHER DEBRIS
6 0B/OG
?
8
9
WAS GROUND WATER ENCOUNTEKED? NO
IF YES ~ WItAT DEP'~Ht__
DEPTH OF WATER AFTER MONITORING: NONE
11 DATE OF MONITORING:. 8/28/2o,
2O
ANDERSON
GRAVEL WITH SILT
GM
SITE PLAN
SEE SITE PLAN
4%
DATE READING GR, OSS TIi'JE ,NET TIM,EI IN,ET DRO, P
TEST HOLE PRESOAKED PRIOR TO TESTING:
PERCOLATION RATE:
TEST RUN BETWEEN:
(MIN/rNCH) PERC. HOLE DIA.
FT. and FT.
i~c~S)
COIV~VIENTS: TEST HOLE TO VERIFY ABSENCE OF BEDROCK.
TEST PERFORMED BY ANDERSON ENGINEERING. I, MICHAEL E. ANDERSON CERTIFY THAT
THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPLE GUIDELINES IN EFFECT ON THIS
DATE: 11/~/2010
4700
DEPTH
1
2
3
4--
5
6--
7--
8--
9--
11
20
MUNICIPALITY OF ANCHORAGE
DEVELOPMENT SERVICES DEPARTMENT
BRAGAW STREET ANCHORAGE, AK
SOILS LOG - PERCOLATION TEST
LEGAL DESCRIPTION:
PERFORMED FOR:
DATE: 8/2Z./2011
PARCEL ID#:
LOT &, BLOCK 5, RAVEN ~IOUNTAIN EST. NO. [
STEVE NORWOOD
PROJECT No.:
TECHNICIAN:. ~1. ANDERSON
PEAT, ROOTS, STUMPS
OTHER DEBRIS
WAS GROUND WATER ENCOUNTERED? --
IF YES ~ W~IAT DEFI~%__
DEPTH OF WATER AFTER MONITORING:
DATE OF MONITORI/q~
OB/0G
DATE
8/24
SLOPE
NO
GRAVEL WITH SILT
GN
SITE PLAN
SEE SITE PLAN
GROSS TINE NET TIMEI DwE/~RT°
INET DROP
READING (MINUTES) (MINUTES) (INCHES) (INCHES)
TEST HOLE PRESOAKED PRIOR TO TESTING'.
4:45/4:55 10 6.5/DRY 6.5
4:56/5:06 10 6.5/DRY 6.5
5:07/5:17 10 6,5/DRY 6.5
5:18/5:28 IO 6.5/DRY 6.5
5:29/5:39 10 6.5/DRY 6.5
5:40/5:50 l0 6.5/DRY 6.5
PERCOLATION RATE: 1.5 (MIN/INCH) PERC. HOLE DIA. 6
TEST RUN BETWEEN: 10 FT. and II FT.
COlvI~NTS: TEST HOLE PRE SOAKED PRIOR TO TEST.
TEST PERFORMED BY ANDERSON ENGINEERING. I, MICHAEL E. ANDERSON CERTIFY THAT
THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MLrNICIPLE GUIDELINES IN EFFECT ON THIS
DATE: 8/25/2011
MUMCPA UTYOF-'-' HCHOR„GE
Development Services DepartmentPhone: 907-343-7904
On -Site Water & Wastewater Section --' Fax: 907-343-7997
Certificate of On -Site Systems Approval
Parcel I.D. 076 03 120
1. GENERAL INFORMATION
Expiration Date: p 1 15 1W � A
Complete legal description RAVEN MOUNTAIN ESTATES#1 BLOCK 3 LOT 4
Location (site address)
220 GOLD CLAIM DRIVE
Current property owner(s) NORWOOD
Mailing address
Real estate agent
2. TYPE OF DWELLING:
Single Family (w/ADU)
[� Duplex
❑ Multiple Dwellings (Single Family and/or Duplex)
Day phone
Day phone
3. NUMBER OF BEDROOMS:
4. TYPE OF WATER SUPPLY:
TYPE OF WASTEWATER DISPOSAL:
Private Well
0
Private Septic
0
Water Storage
❑
Holding Tank
❑
Community Well
❑
Community
❑
Public Water System
❑
Public Sewer
❑
Waiver request for: NONE Distance:
Received by: Date:
COSA to be released to the engineer, unless otherwise requested by the engineer.
COSA Fee $ .5 50
Date of Payment / �yA—, I
Receipt Number
COSA # Z) 16 q 9
Waiver Fee $
Date of Payment
Receipt Number
Waiver #
5. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based
on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the
on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of
bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the
Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater
disposal system is (are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in
effect at the time of installation.
Name of Firm C&M ENGINEERING Phone 8545558
Address 20182 TULWAR
Engineer's Printed Name CHARLES BALZARINI Date 11/2/21
�� A/ -,law
low
TH
Sll�
6. DSD SIGNATURE •• ..•• •�•••• r
System #1 Approved for bedrooms r� • • Z:HARLES G BA RN • j
System #2 Approved for bedrooms63'•. CE -13854 ••��
• ���
Disapproved �ll1FOPROFEss1oNP���=
Conditional approval for bedrooms, with the following stipulations:
See (neer' C�o rvirY1e/t f oh /aS� �
0E 0C'i��-.
yoAM srr-Fn
g
WATER AND rn
rr� WAST`=V"ATER z
J
O
JJJ0,
-�m �
By: Original Certificate Date: 5 1,20.1
The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the
representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is
not responsible for errors or omissions in the professional engineer's work.
7. ATTACHMENTS:
COSA Checklist X Nitrate Advisory
Septic System Advisory Arsenic Advisory
Well Flow Advisory Other
COSA Checklist blue sheet
COSA Checklist yellow sheet
COSA Checklist
Legal Description: Parcel ID:
If more than 1 septic system on lot: COSA Checklist # of Structure served by this system
A. WELL DATA
Well log is filed with Onsite (or attached)
Date drilled
Total depth ft
Cased to ft
Sanitary seal is functioning correctly
Wires are properly protected
Casing height (above ground) in.
Date of flow test for COSA
Static water level at beginning of test ft.
Well production at time of test gpm
Water storage tank volume gallons
Well disinfected for coliform test? Yes No
Coliform bacteria is Negative
Nitrate mg/L Nitrate less than MRL (ND)
Arsenic ug/L Arsenic less than MRL (ND)
Collected by
Date of Sample
Comments __________________________________________________________________________________
C. LIFT STATION
Required maintenance completed
Age of lift station years
Lift station material
Comments:
ALL standpipes present per record drawing
Total measured depth from grade ft (max)
Measured depth to pipe invert from grade ft (min)
N/A – pressurized field
Monitor tubes go to bottom of effective. If not, state
depth into effective
Code-required soil cover over field
System presoaked
(Required if vacant for greater than 30 days prior to
date of test)
Gallons introduced gallons
Adequacy test date
Results Pass For bedrooms
Fluid depth prior to test in
Water added gal
New depth in
Elapsed time min
Final fluid depth in
Absorption rate gpd
Any rejuvenation treatment (past 12 months)
If yes, enter date
Comments/Deficiencies:
B.TANK DATA
Age of tank(s) years
Tank type/material6WHHO
Measured operating fluid level in septic tank
Standpipes/foundation cleanout per record drawing
Date of pumping
D.ABSORPTION FIELD DATA ______________________
Which system tested (date installed)
RAVEN MOUNTAIN ESTATES#1 BLOCK 3 LOT 4 076 031 20
11 1
+3
09/23/2013 1200
97
90
1.26
+24 C.Balzarini
10/28/21
79**
11/10/2021
Pump log not available. ** From well log, it was not possible to measure the static water level.
10
Septic
50
10/19/21
bed
2011 10/28/21
2
9 0.25
8 300
1
15
0
300
NA
NA
North MT has some minor debris. Does not impact function of system.
✔
COSA Checklist yellow sheet
E. SEPARATION DISTANCES
From Private Well on Lot to: (Please enter distances if less than required or if community well)
Septic Tank/Lift Station on Lot > 100’
Yes if No ft
Neighboring Tank > 100’ Yes if No ft
Absorption Field on Lot > 100’ Yes if No ft
Neighboring Absorption Fields > 100’
Yes if No ft
Community Sewer Main > 75’ Yes if No ft
Community Sewer Manhole/Cleanout > 100’
Yes if No ft
Private Sewer/Septic Line > 25’ Yes if No ft
Holding Tank > 100’ Yes if No ft
Animal Containment > 50’ Yes if No ft
Manure/Animal Excreta Storage > 100’
Yes if No ft
From Septic/Holding Tank on Lot to:(Please enter distances if less than required)
Building Foundations > 10’ Yes if No ft
Property Line > 5’ Yes if No ft
Absorption Field > 5’ Yes if No ft
Water Main > 10’ Yes if No ft
Water Service Line > 10’ Yes if No ft
Surface Water > 100’ Yes if No ft
Wells on Adjacent Lots:
Private Wells > 100’ Yes if No ft
Community Wells > 200’ Yes if No ft
If septic tank is under driveway comment below
From Absorption Field on Lot to: (Please enter distances if less than required)
Building Foundation > 10’ Yes if No ft
Property Line > 10’ Yes if No ft
Water Main > 10’ Yes if No ft
Water Service Line > 10’ Yes if No ft
Surface Water > 100’ Yes if No ft
If absorption field is under driveway comment below
Wells on Adjacent Lots:
Private Wells > 100’ Yes if No ft
Community Wells > 200’ Yes if No ft
F. ENGINEER’S COMMENTS
G. ENGINEER’S CERTIFICATION
I certify that I have determined through field inspections and review
of Municipal records that the above systems are in conformance with
MOA COSA guidelines in effect on this date.11/06/21
✔✔
✔
✔
✔
✔
✔
✔
✔✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
This is an off the grid home. The well is powered by generator. The water storage tank,
waterline, and sewer lines may freeze if not properly drained or kept heated.
The buyer should familiarize themselves with the operation of the water/sewer system.
✔
AMW
OF.q\11l
�,•� •e
�,•, L-176
l
�f•SS11 .NI P
0 20 40
US SURVEY
V0.01, FEET
NOTES '
-All dimensions shown are grid bearings and ground distances, Record boundaries are per Plat No. 66-161.
-49th Star has conducted a physical survey of the property and all details shown on this Asbuilt Survey are correct. Under
no circumstances should any data hereon be used for construction or for establishment of property lines.
-It is the owners responsibility to determine the existence of any easements, covenants, or restrictions which do not appear
on the recorded subdivision plat.
AS BUILT SURVEY
Lot 4, Block 3,
Raven Mountain
Estates, Unit 1,
Girdwood, AK
LEGEND
® Septic Cleanout
O Well
49th Star Surveying U_%'
PO Box 738
Girdwood, AK 99587
(907)891-6111
Jeremy@49thStarSurveying.com
W.O. 2144 1 DATE: 11/11/21
SCALE: 1 "=40'