HomeMy WebLinkAboutT12N R3W SEC 23 PARCEL 18A & 19ATI 1 3W
Po.r'cel !SA &
#015-234-60
Permit Number:
Tax Code Number:
Work Type:
On-Site Wastewater Disposal System Permit
OSP131343
01523460000
Septic
MUNICIPALITY OF ANCHORAGE
Development Services Department
On-Site Water & Wastewater Program
4700 Elmore Road, PO Box 196650
Anchorage, AK 99519-6850
Telephone: (907) 343-7904
Permit Effective Dates: October 04, 2013 to October 04, 2014
Design Engineer: PANNONE ENGINEERING SERVICE
Subdivision: T12N R3W SEC 23
Site Legal Address: T12N R3W SEC 23 PARCEL 18A & 19A G:2738
Owner/Address: WOOLIVER JOAN
6201 E HUFFMAN ROAD ANCHORAGE AK 995162442
Site Mailing Address: 6201 HUFFMAN RD, Anchorage
Lot Size in Sq Ft: 108900
Total Bedrooms: 4
)artment
This permit is for the construction of:
Y Disposal Field Y Septic Tank N Holding Tank N Privy N Private Well N Water Storage
All construction must be in accordance with: 1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater
Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80).
3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services
Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either:
A. Open and Close on the same day.
B. Covered, sealed, and heated to prevent freezing.
Date:/~)/-f/~'~
Date:
MUNICIPALITY OF ANCHORAGE
Community Development Department
Development Services Division
On-Site Water & Wastewater Program
~" Phone: 907-343-7904
Fax: 907-343-7997
ON-SITE SEWER/VVELL PERMIT APPLICATION
Parcel I.D. 015-234-60
Property owner(s) Joan Wooliver Day phone
Mailing address 6201 E. Huffrnan Road, Anchorage, AK 99516
Site address 6201 Huffman Road
Legal description (Sub'd., Block & Lot) Parcel 18A & 19A
Legal description (Township, Range & Section) T12N, R3W, Sec 23
Lot Size 108,900 .Sq. Ft. Number of Bedrooms 4
APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING:
(D;~ all that apply)
Absorption Field [] initial [] Single Family (SF) []
(w/wo ADU)
Septic Tank [] Upgrade []
Duplex (D) []
Holding Tank [] Renewal []
Multiple Dwellings []
Privy [] (SF and/or D)
Private Well []
Water Storage []
THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR:
Distance:
I certify that the above information is correct. I further certify that this is in accordance with
applicable Municipal Codes.
(Signature of property owner or authorized agent)
Permit/Rush Fees:
Date of Payment:
Receipt Number:
Permit No.
Waiver Fees:
Date of Payment:
Receipt Number:
Waiver No.
Permit App_L'- :- :£.,~c;
Pannone Engineering Services LLC
Steven R. Pannone, Principal
Registered Professional Engineer
E-mail: steve(~Danen~ak.com
September 18, 2013
Municipality of Anchorage
Development Services Department
On-Site Water & Wastewater Program
4700 Elmore Road
P. O. Box :[96650
Anchorage, Alaska 99519
Subject:
T:[2N, R3W, Sec 23, Parcel 18A & 19A
Septic System Upgrade Permit Request
Ladies and Gentlemen:
I am writing to request a permit to install an upgrade septic system be issued for this property. The
proposed systems will serve an existing four (4) bedroom house. The system will consist of a drain field
and will utilize a 1500g S.T.E.P. tank, with AX20 pod. Currently the lot is developed. The septic system will
be located over 100 feet from the well. The surrounding developed lots are also served by a class 'A'
water system. There are no surrounding wells within 200 feet of this system.
1. Soils. One test hole was excavated by Pannone Engineering Services in September of 2013, and the
ground water monitored for seven days. The test hole was dry after the seven day monitoring period.
Bedrock was not encountered in the test hole. It is my opinion, based on the results of the percolation
tests and overall soils appearance; an application rate of 4.0 gallon/day/square feet should be used for
the conventional system.
Soil Absorption System Design.
a. See Sheet 2 of the design package.
3. Surface Water: There is no surface water within 100 feet of the proposed septic tank and drain
field. The proposed drain field upgrade will maintain at least 100 feet from all surface water and drainage
ditches.
4. Topography: The topography slopes from west to east at approximately 20% in the area of the
proposed drain field. There are no steep slopes in the area.
S. Drawing Markings: The Drawings are marked "For MoA Review Only". When written notification
that the review is complete and that there are no further comments is received from MoA On-Site
Department, the note will be removed and "Issued for Construction" drawings will be issued.
Mailing: P,O~ 13ox t002~t7, Anchorage, Al( 995:[0-02:[7
Physical: 332 East Manor~ Anchorage~ AK 9950:[
Telephone: (907) 272-82:[8 FAX: (907) 272-82:[:[
Page 2 of 2
The proposed installation will not affect the future development of the surrounding or existing lots. There
are no wells or septic systems within :100 feet of the proposed septic location.
If you have any questions or concerns, please contact me at 272-82:18.
Sincerely,
Steven R. Pannone, P.E.
Owner/Civil Engineer
Attachments
-Soils Log
-Septic System Design
Mailing: P.O. Box :1002:].7, Anchorage, AK 995:10-02:[7
Physical: 332 East Manor Ave, Anchorage, AK 9950:1
Telephone: (907) 272-82:[8 FAX: {907) 272-g2z:1
Municipality of Anchorage
P.O Box 196550 4700 Elmore Road
Anchorage, Alaska 99519-6650 (907) 343-7904 Fax (907) 343-7997
htto:l/www, mu ni.oralo nsite
Planning and Development Services Department
On-Site Water and Wastewater Program
On-Site Sewer/Well Submittal Comment Sheet
Engineer: PANNONE ENGINEERING SERVICE
Legal Description: T'I2N R3W SEC 23 PARCEL 18A & 'I9A
9/25/2013
Permit: OSP131343 Septic Completed By:
Report Type: On-Site Review
D.Wockenfuss
The attached paperwork has been reviewed and is being returned for the following reasons:
1. Show the foundation clean out on the site plan.
2. Show the existing tank location and state that it will be decommissioned./~/~- A)O/~'~l.~'Tt ~v/[''- ~-~g.A//~',
3. Pemolation test must be taken in each soil strata that will be used as absorption area. AMC 15.65.060.B.2. Since
the field is oversized and if the upper strata are not impermiable, can the design be justified in the lower part of the
field but keep the proposed effective depth? Call to discuss. ~:~IF~.t2
4. The proposed reserve fieldJs higher in elevation than an excessive slope that is less than 50' to the west. Waiver
request and fee required, t--J~',A ~3c4 0-v~'~/~ ~
5. After the "Review Only' drawings have been reviewed and you are notified that there are no additional comments,
the "For Construction" drawing must be submitted before the permit is issued. The permit won't be issued until the
two sets of drawings have been compared.
6. Sheet 2 says the field is a 5' wide. Is this correct? ~g2.
7. Missing the AVWVI'S Maintenance Agreement. AMC 15.65.360.B
8. The point of access for the pump truck must be no more than 100 feet from the septic tank. The ground surface at
the point of access for the pump truck must not be more than 11 feet higher than the bottom of the septic tank. AMC
15.65.050.G. Is there access that is closer? If not, A-plus needs to submit a statement saying that they can service
the system. /~,'~::::,~.(:~,J,A"'/-iJ, t[~ ~O L,L~J-~ *'-~---~¥~-'~:~*~'~ ---*~l"2,J a ~,,
........ ~' / ,, ~ .... ~", '~ ~,X ,, Fl
.~. ~ . : ~... . , ~ U,x '.~..~ ~..
~ '~ ~., .. / / ~ ~~'~ -~.
...... ~ , ' ~ / ,, ~ ,~ TOcR~EK ~.
'-.. . ' , ~ '~ , ' . ~ -. . .. -~.
, ' '~ ~ t ' '~ /'/ ;/~ ~ 100 SETBACK
I ..... , ,. ,. ., ~ ,, ~t . ~ ., ,,
~ SEPTIC AREA (E) ~ ~ ' ' ~ I / ~' .. ~e.,
--CESSPOOL (E)
, 15009 S.T.E.P. TANK (F)~ ..I ...... ABANDON PER CODE
~ WITH AX20 POD AND DCO .¢¢. --~ "::"' ~
"x ' - x ~ / -' ' ~ ~l "',
'.B .. . ~... / ~ x~ · . ..
~, x, ~ X x xk /, x ., 4 BR ~ ~ '
FOR CONSTRUCTION P,O, BOX 100217 ANCNORA~E, AK 99510 ~.~ ......
....
~ .......... ~,I,D. NO
~~ 915 2~-60
T12N, RSW, SEC 23, PARCEL 18A & I9A ~.~
GEORGE AND JOAN WOOLIVER ~,~... CE 8149 .~ 'PERMIT NO.
6201 E. HUFFMAN ROAD ~A.. ..~ OSPlS~S4~
PLAN ANCHORAGE, AK 99516 ~~v~ Sheet
SPECIAL PROVISIONS TO SPECIFICATIONS
1. ALL CONSTRUCTION SHALL BE INSTALLED AS SPECIFIED IN THE MOST CURRENT EDITION OF THE MUNICIPALITY OF
ANCHORAGE STANDARD SPECIFICATIONS (MASS) FOR COMPONENT PARTS AND MATERIALS USED IN CONSTRUCTION OF
ON-SITE WASTEWATER DISPOSAL SYSTEMS.
5, SCOPE OF WORK: INSTALL NEW 15009 S.T.E.P. TANK WITH AX20 POD AND SOIL ADSORPTION SYSTEM.
4. GROUNDWATER WAS NOT ENCOUNTERED AS EVIDENCED BY THE SOIL TEST HOLE. IF AN APPARENT WATER TABLE IS
OBSERVED IN ANY OF THE EXCAVATIONS LESS THAN 19.0 FEET BELOW EXISTING GRADE NOTIFY THE ENGINEER
IMMEDIATELY.
FILTER FABRIC
sw . -- O.B
GM/ ~_ ~J~-DRAIN ROCK
o _~ ~- ~ filteR FABriC
o ~ ~o
A~REVIATIONS
CU COPPER
DESIO~ PARAMETER~ DiP DUCTILE IRON PiPE
PRIMARY/RESERVE sePtiC SYSTEM Th TeSt HOLE
LEGEND NO. BEDROOM: 4 (600 gpd) FC FOUNDATION CLEAN OUT
W- WATER LINE/ TANK SIZE: 15009 S.T.E.P. T~ TANK CLEAN OUT NO.
W/AX20 POD C~ CLEAN OUT NO.
WELL RADIUS PERC RATE = 13.5 MPI
SOIL RATING: 4 GPD/SF MC MONITOR TUBE NO.
R.I. RIGID INSU~TtON
~ SS ~ NEW SEPTIC AR~ RQD: 150 SF
SYS. ~PE: DEEP TRENCH 6.5'ED DCO DOUBLE CLEAN OUT
MIN LENGTH: 11.5 LF DV DIVERTER VALVE
FS FLOW SPLICER
USE: BFG BELOW FINISH GRADE
15LF x 5'W x 6.5'ED x 13.O'TD OG ORIGINAL GRADE
TOTAL AREA: 195 SF FO FINISH GRADE
TSAV TOPSOIL A VEO~ATE
OT S: Dote
FOR CONSTRUCTION P.O. BOX 100217 ANgHORAGE, AK 99510 ~ ..... .~ 10/~/201~
PHO~ (~07) ~7~-a~ FAX (~07) ~7~-~ ~Z..' ~:~', S~o,~
NTS
P.I.D. ~0
T12N, R3W, SEC 23, PARCEL 18A & 19~ ~'P~h~6~: ~4-~0
GEORGE AND JOAN WOOLIVER ~ ~. CE ~149 ..;~ :ERMl~ NO.
~20~ E. HUFFMAN ~OAD ~e~. ~....
DESIGN DETAILS ANCHORAGE, AK 99516 l~0E~ ~
SOILS LOG - PERCOLATION TEST
TEST HOLE 1
/: ,f ' ? 81TE RLAN ~ ~ i ' ,
OR/ I ORGANICS/ SLOPE ~
1 -- GL ORGANIC SILT ,/ , / / ' 20 'UTILI~ EASEMENT., \ ",,
,-" ,-. '.=--'.,'""
SILTY GRAVEL
4 -- SW SANDY VAIN " i ,' -', ~- · ~, , ' ' ~ ',... ~ ' \
7-- 't ,: ? .! i TH
WAS GROUND WATER SLOPE
14 -- ENCOUNTERED? N
15 -- IF YES, AT WHAT TH
DEPTH? -DRY' X
17 -- DEPTH TO WATER AFTER
MONITORING? -DRY'
18 -- DATE: 9/18/2013
I 9/03/13 12:20 .- 4.39 --
2 12:30 10 MIN 5.11 0.72
3 12:30 ~-- 4.39 --
4 12:40 10 MIN 5.10 9.71
5 12:40 -- 4.39 -'
I
s 12:50 10 MIN 5.13 0.74
PEROLATION RATE 13.5 (rain/inch) PERC HOLE DIAMETER 6 inches
TEST RUN BETWEEN 6.5 FTAND 7.5 FT
COMMENTS: Test hole excavated by A+ HOME SERVICES. Perc hole was presoaked. Last 3 readings recorded.
PERFORMED BY: Steven R. Pannone~ P.E. I CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE
WITH ALL STATE AND MUNICIPAL GUIDLINES IN EFFECT ON THE DATE OF THIS TEST.
NOTES: PANNONE ENG SVC, LLC ~'~h oo~
· 9/26/2013
FOR CONSTRUCTION P.0. B0× 100217 ANCHORAGE, AK 99510 ~"~..~. .....
~o~ (90?) 272-a2~s [~x (907) 272-s2~ ~o%.' ~::.'.~r'~ soo,o
.':.t!
T12N, R3W, SEC 23, PARCEL 18A & 19A.~....._n.n.6r~e ~~X.~o~ u%5:-254-6o
GEORGE AND JOAN WOOLIVER'~:"~"~'" CE 8149 .Z-~. PERmiT NO.
620t E. HUFFMAN ROAD ~ '~t~ '"
SOILS LOG ANCHORAGE, AK 99516 ~ Sheet
WATER
CLOCK
READING DATE NET TIME LEVEL NET DROP
TIME
READING
I 9/03113 12:20 .- 4.39 -.
2 12:30 10 MIN 5.11 0.72
3 12:30 ... 4.39 --
4 12:40 10 MIN 5.10 9.71
~ 12:40 -. 4.39 -.
s 12:50 10 MIN 5.13 0.74
ADVANTEX DESIGN
ADVANTEX 24" PASSIVE
4" dim CAP AX20 POD~ INSULATED AUXILIARY AIR
~ i ~ a RISER, PUMP ~ VENT~
4" PUMP-OUT/. I111 J
SLIDE SECTION ¢ffiBq k /
OF 6" PIPE ~ I
OVER THIS CONNECTION - i ~
TO PROVIDE
SHEER PROTECTION- , ~
EXTEND TO = 12
BRIDGE EXCAVATION
NOTES: P~O~ ~O ~C, L~
~ 9/26/2015
FOR CONSTRUCTION P.O, BOX 100217 ANCHORAGE, AK 99510
~:. ~21~ s~,~
............--~~- P.l.D. NO
T12N, RSW, SEC 25, PARCEL 18A & 19A.
$(even R. Ponno~e
GEORGE AND dOAN WOOLIVER[:¢~¢~" CE 8149 ';%~ PERMIT NO.
620] E. HUFFMAN ROAD ~'II;' ~0~9~ Sheet
SITE SECTION ANCHORAGE, AK 99516 ..~_~ ......
ADVANCED WASTEWATER TREATMENT SYSTEM
MAINTENANCE AND REPAIR AGREEMENT
BETWEEN MUNICIPALITY OF ANCHORAGE
AND
THIS MAINTENANCE AND REPAIR AGREEMENT made and entered into as of this
.~ ~Dayof .~-~ 7t. of20/'~byandbetween ~t;~t~
herein the "OWNER," and the Municipality of Anchorage, herein the
"MUNICIPALITY." In consideration of the mutual covenants contained herein, the
parties to this Maintenance and Repair Agreement agree as follows:
1. Advanced Wastewater Treatment Systems. Municipality grants permission to
Owner to utilize and operate an Advanced Wastewater Treatment System
(AWWTS), described as
located at (legal description).
2. Definitions.
IgA
Alteration. Any change to the design or function of an AWWTS that
includes the installation or removal of any parts, components or pieces not
included in the original construction permit and design.
Certificate of On-Site Systems Approval (COSA). An approval by the
Municipality of existing water and wastewater disposal systems given at
the time of property sale and title transfer in accordance with Anchorage
Municipal Code (hereinafter, "AMC") 15.65. These approvals certify that
H. Owner agrees that the AWWTS installation and maintenance requirements as
provided by the AWWTS vendor/installer and approved by the Municipality are
the governing guidelines for the construction, maintenance and repair of the
Owner's AWWTS.
6. Nonwaiver. The failure of either party at any time to enforce aprovision of this
Maintenance and Repair Agreement shall in no way constitute a waiver of the
provisions, nor in any way affect the validity of the Maintenance and Repair
Agreement or any part hereof, or the right of such party thereafter to enforce each and
every provision hereof.
7. Amendment.
A. This Maintenance and Repair Agreement shall only be amended, modified or
changed by a writing, executed by authorized representatives of the parties, with
the same formality that this Maintenance and Repair Agreement was executed
with, and such writing shall be attached to this Maintenance and Repair
Agreement as an amendment.
B. For the purposes of any amendment modification or change to the terms and
conditions of this agreement, the only authorized representatives of the parties
are:
a. Owner:
b. Municipality: Director, Community Development or designated authorit~
C. Any attempt to amend, modify, or change this contract by either an unauthorized
representative or unauthorized means shall be void.
the systems are adequate for the homes that they support and meet the
codes that were in place at the time of system construction.
Damage. Any man-made or natural change in a system that would inhibit
the system from performing as designed.
Maintenance and Repair. The scheduled and as needed replacement of
existing parts, components and pieces of an AWWTS that were included
in the original design which would allow the AWWTS to continue to
perform as designed.
Permit. An On-Site Wastewater Disposal Permit as required by AMC
15.65 to construct and operate an AWWTS.
3. Term. The term of this Maintenance and Repair Agreement shall begin on the
date of approval by the Municipality to operate the installed system or issuance of a
COSA, and shall continue while the AWWTS is in use or is operational or until the
property is sold or title is transferred by the owner and a uew COSA is issued to the
new owner or transferee of the property.
4. Alterations~ Installation and Removal of Additional Equipment. Prior to
performing any alterations to an AWWTS, the owner agrees to obtain an On-site
Wastewater Disposal Permit from the Municipality in accordance with AMC 15.65.
5. Maintenance and Repairs.
A. Throughout the term of this Maintenance and Repair Agreement, the Owner shall
maintain their AWWTS in a satisfactory condition capable of producing treated
septic effluent in accordance with the equipment's approval for operation in the
Municipality. The owner shall enter into a service agreement with an AWWTS
service and maintenance provider approved by the municipalit3, and the
manufacturer of the AWWTS for the entire term of the AWWTS. In addition, it
shall be the responsibility of the Owner during the term of this Maintenance and
Repair Agreement, and any renewals thereof, at the owner's sole expense, to pay
for any and all: (1) repair(s), (2) maintenance, (3) adjustment(s), (4) replacement
costs, and (5) inspection costs.
B. Owner agrees to comply with all applicable ordinance, laws, regulations, rules
and orders for the AWWTS.
C. Upon request by the Municipality, the owner agrees to provide the Municipality a
written schedule of routine maintenance and repairs which have been performed
on the system. When a record of maintenance is documented and maintained by
the system vendor, the owner agrees to allow the Municipality access to this
information.
D. Owner acknowledges that the fine for failing to maintain and repair an AWWTS
may be assessed in accordance with AMC 14.60 for improper discharge.
E. Owner agrees that only maintenance and repair personnel approved by the
Municipality will inspect and make any necessary maintenance, repairs or
permitted alterations to the system.
F. Owner agrees to grant the Municipality reasonable access to test and inspect the
AWWTS upon 24 hours written notice.
G. Owner agrees that any sale or transfer of title of the property will not occur
without a new Certificate of On-Site Systems Approval.
8. Jurisdiction: Choice of Law. Any civil action arising from this Maintenance
and Repair Agreement shall be brought in the Superior Court for the Third Judicial
District of the State of Alaska at Anchorage. The laws of the State of Alaska shall
govern the rights and obligations of the parties under this Maintenance and Repair
Agreement.
9. SeverabiHtv. Any provisions of this Maintenance and Repair Agreement decreed
invalid by a court of competent jurisdiction shall not invalidate the remaining
provisions of the Maintenance and Repair Agreement.
OWNER:
w,.j o3,/o / ~o~,~/~cf~ (print name)
STATE OF ALASKA
THIRD JUDICIAL DISTRICT
The foregoing instrument was acknowledged before me this~ day of ~)0~
2013 , by ~{3c~ ~3C~\W°.ff
NOTARY PUBLIC FOR A,~ASKA
My Commission expires: /v[C~ch ~ t )f)l~
MUNICIPALITY:
(signature) Date:
.(print name) Title: