Loading...
HomeMy WebLinkAboutT12N R3W SEC 27 LT 59TI 27 Lot #018-092-43 Permit Number: Tax Code Number: Work Type: On-Site Wastewater Disposal System Permit OSP131335 01809243000 Septic MUNICIPALITY OF ANCHORAGE Development Services Department On-Site Water & Wastewater Program 4700 Elmore Road, PO Box 196650 Anchorage, AK 99519-6650 Telephone: (907) 343-7904 Permit Effective Dates: September24, 2013 to September24, 2014 Design Engineer: ANDERSON ENGINEERING Subdivision: T12N R3W SEC 27 Site Legal Address: T12N R3W SEC 27 LT 59 G:2936 Owner/Address: REINERT ROBERT W 13350 RIDGEWOOD ClR ANCHORAGE AK 995162940 Department Site Mailing Address: 4501 DE ARMOUN RD, Anchorage Lot Size in Sq Ft: 54450 Total Bedrooms: 3 This permit is for the construction of: Y Disposal Field Y Septic Tank N Holding Tank N Privy N Private Well N Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80). 3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either: A. Open and Close on the same day. B. Covered, sealed, and heated to prevent freezing. Date: MUNICIPALITY OF ANCHORAGE Community Development Department Development Services Division On-Site Water & Wastewater Program Phone: 907-343-7904 Fax: 907-343-7997 ON-SITE SEWEPJWELL PERMIT APPLICATION Parcel I.D. 018-092-43 Property owner(s) Robert W. Reinert Day phone Mailing address 13350 Ridgewood Circle Anchorage, AK 99516 Site address 4501 De Armoun Road Anchorage, AK 99516 Legal description (Sub'd., Block & Lot) T12N R3W SEC 27 LT 59 Legal description (Township, Range & Section) Lot Size 54,450 .Sq. Ft. Number of Bedrooms Four (4) APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (~;~ all that apply) Absorption Field [] Initial [] Single Family (SF) [] (w/wo ADU) Septic Tank [] Upgrade [] Duplex (D) [] Holding Tank [] Renewal [] Multiple Dwellings [] Privy [] (SF and/or D) Private Well [] Water Storage [] THIS APPLICATION INCLUDES A VARIANCE /WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit/Rush Fees: Date of Payment: Receipt Number: Permit No. Waiver Fees: Date of Payment: Receipt Number: Waiver No. Permit App_9-1-12,doc September 15, 2013 Municipality of Anchorage Development Services Department On-Site Water and Wastewater Program 4700 Elmore Road Anchorage, AK 99519-6650 Subject: Lot 59, Section 27, T12N, R3W Septic System Design and Permit Application Impacts to Adjacent Properties Dear Onsite Services Engineer: The existing absorption pit on the subject lot has failed and must be replaced. We are therefore requesting a permit be issued for the upgrade of the septic system to accommodate the three-bedroom home on the lot. The septic system will be constructed to serve a future four-bedroom home. The attached Site Plan and backup documentation identify the location and configuration of the existing and proposed septic system. The existing absorption pit will be decommissioned in accordance with Municipal Code. Also identified on the plans are the locations of the existing well on this and adjacent lots and adjacent septic systems. No conflicts exist between the proposed septic system and the wells on this or adjacent lots. Protective radii are shown to the adjacent wells. Drainage arrows are shown indicating the current drainage patterns. The drainage patterns will be maintained after construction. The test hole placed on the lot indicated Silty Gravel with Sand (GM) to a depth of 15'. No groundwater was encountered during placement of the test hole and none has developed during the monitoring period. The percolation rate in the GM soil lense was determined to be less than 5 minutes per inch. We have designed the new trench with an application rate of 1.2 gallons per day per square foot. We are proposing to place a 50' long by 5' wide absorption trench with a 4' effective depth. The total depth of the system will be 8' with the distribution line at 4' below the existing surface. The ground surface on the lot is virtually fiat in the area of the absorption trench with a slight bias to the south. The trench will be placed parallel to the contours of the ground as much as possible and in conformance with design criteria. A minimum of 100' will be maintained between all components of the septic system and the proposed well and Lot 59, Section 27, TI2N, R3W September t5, 2013 Page Two from any surface water in the area. If the system is constructed in accordance with our design the following statements apply: ]. The system, if constructed as designed, will have no adverse impact on the wells in the area or those to be constructed in the future. 2. The system, if constructed as designed, will have no adverse impact on existing septic systems in the area or those to be constructed in the future. 3. The system, if constructed as designed, will have no adverse impact on reserve space, either surface or subsurface, on any lots located in the area. 4. The system, if constructed as designed, will have no adverse impact on drainage patterns in the area. The current drainage pattern will be maintained. Sincerely, Michael E. Anderson, P.E. Attachments LOT 47 LOT 46 LOT 45 ~ / ~ T1 2N R3W , SECTION 27 LOT 59 /~ I ' ~~ , ~/ RESERVATION ' : ~q.~',. DEARMOUN ROAD LOT 59, SECTION 27, T12N, R3W DESIGN FACTORS: SYSTEM REQUIREMENTS: Four Bedroom Home 5' Wide Trench System Perc. Rate: 2.5 Min./Inch 1,500 Gallon STEP Tank Application Rate: 1.2 GPD/SF 2' Drainfield Rock 4 Bedrooms X 1.50 GPDI1.2 GPD/sF (Application Rate)= 500 SF Absorption Area 500 SF/5 SF/LF .7 (Red. Factor) = 70 LF Trench Length THEREFORE: Construct 2-35' Long x 5' Wide x 2' Effective Depth Aborption Trenches at the Location Shown. Flow Line Elevation in Trenches to be 1' Below Original Ground Surface. Total Depth to be 3' Below Existing Ground. Provide 3' of Cover Over Trench and 4' Over Tank or Provide 2" of Insulation and 2' of Cover. Maintain 10' Separation From Water Services in the Area. tural ckfill ~ 6" ,-, ~ 2'0" Geotextile "'"' Fabric '~ 1.25" Perforated PVC (Holes Down) 15 3/16" Holes per Lateral @ 2.67' Spacing % Drainfleld Rock 51 I - TYPICAL 5' WIDE TRENCH SECTION (NO SCALE) ,~.~-,,~: ................. NOTE: Grade Area Over Trench to Dra~n Away, E~: Minimum 6 Separatmn From Bedrock. ~=.~......~...,,~ ........... ~,,,,,.,~....,~ Minimum 4' Separation From Groundwater. . ~~ Minimum 100' Separation From Private Wells ~n the Area. ~[~'."~;~7~ Minimum 100' Separation From Sufiace Water or Streams. ~'~'~ Minimum 10' Separation From Water Se~ice Line. ' ~2'% 4700 DEPTH (feed l 2-- 3 4-- 5 6 7 8 9 11 20 MUNICIPALITY OF ANCHORAGE DEVELOPi'tENT SERVICES DEPARTMENT BRAGAW STREET ANCHORAGE, AK 99519-O650 SOILS LOG - PERCOLATION TEST LEGAL DESCRIPTION: lOT 59, SECTION 27, TI2N, RSW PERFORIViED FOR: ,,JERRY RICHIE DATE: 7/20/2015 PROJECT No.: PARCEL ID#: TECHNICIAN: NEA [ TEST HOLE ] PT/OL SILTY GRAVEL WITH SAND BOH @ 15' WAS GROUND WATER ENCOUNTERED? -- SLOPE SITE PLAN SEE SITE PLAN I DEPTH TO DATE READING GROSS TINEiNET TIHE WATER NET DROF (MINUTES) (MINUTES) (INCHES) (INCHES) TEST HOLE PRESOAKED PRIOR TO TESTING: 8/27 1 9:14 1.50" 2 9:44 30 9.00" 7.50" 3 9:45 1.25" 4 I0:15 30 8.75" 7.50" 5 i0:17 1.50" 6 10:47 30 9.00" 7.50" PERCOLATION RATE: 4.1 (MINm'4CH) PERC. HOLE DIA. 6" .(INCHES) TEST RUN BETWEEN: 4.0 FT, and 5.0 FT. COMMENTS: TEST HOLE PRE SOAKED PRIOR TO TEST. TEST PERFORMED BY ANDERSON ENGINEERING. I, MICHAEL E. ANDERSON CERTIFY THAT THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPLE GUIDELINES IN EFFECT ON THIS DATE: 9/15/13 X6789To • 9 ?G E • .� Municipality of Anchora• •On-Site Water and Wastewater Program Q < ILL11■ (907) 343-7904 OCT 2 6 2017 E T Y ti Certificate of On-Site Systems Appro“- ,1 6 8 L c'' Parcel I.D. 018-092-43 Expiration Date: / -30 - I 1. GENERAL INFORMATION: Complete legal description T12N R3W, SECTION 27; LOT 59 Location (site address) 4501 DeArmoun Road *Anchorage 99516 Current Property owner(s) Nick&Melissa Strautins Day phone Mailing address Real Estate Agent Day phone 2. TYPE OF DWELLING: ® Single Family (w/wo ADU) El Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) 3. NUMBER OF BEDROOMS: 3 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well ® Individual Individual Water Storage ❑ Holding Tank ❑ Community Class Well ❑ Community ❑ Public Water System ❑ Public Sewer ❑ WaiverNariance request for: Distance: Received Date: ID(31 /(`4 COSA to be released to the engineer, unless otherwise requested by the engineer. ` V COSA Fee $ Waiver Fee $ Date of Payment /QNfg' Date of Payment Receipt Number /b e) Receipt Number COSA# C6 /`3-16-0(-1 Waiver# 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm: Garness Engineering Group, Ltd (GEG) Phone: 907-337-6179 Address: 3701 East Tudor Road, Suite 101-Anchorage,Alaska 99507 Engineer's Printed Name: Jeffrey A. Garness Date: t o f Z 5/1 - �0000_000 In conducting this evaluation, GEG provided an engineering evaluation of the well and/or septic system oQ OF A 1, '% % in accordance with the guidelines and regulations established by the Municipality of Anchorage and � . '; industry practices. The reported results describe the condition of the system/s on the date/s of the QO P.•' evaluation. Separation distances were measured to readily identifiable features. Hidden defects or �1n1 encroachments may exist that were not identified during the evaluation. The operational life of all wells / * A 9 T 9 VD and septic systems depend upon a variety of variables, including but not limited to, soil conditions, Q groundwater levels (that may fluctuate during the year), quality of construction (materials and VA workmanship),and the water usage of the family utilizing the system/s. These conditions can vary,and % are outside the control of GEG. Satisfactory test results do not guarantee future performance of the a Jef - f:• ss;' system's; therefore, GEG makes no warranty (express or implied) regarding the future performance of A P • �' 7053 • the well or septic system. GEG makes no representation whether an alternative well or septic system ( `i • + .�c� can be installed on the property in the event either of the current systems fail to perform adequately in %4 P,-. •1.0.j. 5 !f <*go the future. The content of this report is for the sole benefit of the person/party that retained GEG to ��Pdprpfess'or°oma perform the evaluation. Reliance upon the information provided in this report by any other person or 4���4O�o� party (including subsequent property purchasers) is not authorized, nor will it confer any legal right whatsoever. #AECC884 6. DSD SIGNATURE System #1 Approved for 3 bedrooms System #2 Approved for bedrooms ; `,.` Qp,LIT1 /1/ Y Disapproved ;-. -) :; Conditional approval for bedrooms, with the followir Vipu,t0VsS�mJ-� 0�l; vv oWASr 'VD m pRDG TER _F RAM kRVIC • By: 4111 .1 ��� Original Certificate Date: / D= c The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On-Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: ` • COSA Checklist X Nitrate Advisory Septic System Advisory Arsenic Advisory Well Flow Advisory Other COSAblue sheet 10.10.12.doc If more than 1 septic system is on the lot: COSA Checklist # of Structure served by this system Certificate of On-Site Systems Approval Checklist Legal Description: T12N, R3W, SECTION 27 LOT 59 Parcel ID: 018-092-43 A. WELL DATA `PER GEG INSPECTION Well type PRIVATE If A, B, or C provide PWSID# N/A Well Log (Y/N) NO Date completed 19620! Sanitary seal (Y/N) YES Wires properly protected (Y/N) YES Total depth *83+ ft. Cased to UNK ft. Casing height (above ground) 18+ in. FROM WELL LOG AT INSPECTION Date of test 10/9/17 G Static water level .E��BOft. 78 5 ft. Well production • g.p.m. 3.6+ g.p.m. WATER SAMPLE RESULTS: Coliform 0 colonies/100 ml. Nitrate-3' Img./L. Collected by: GEG, Ltd Arsenic: NAIL. Date of sample: 10/6/17 B. SEPTIC/HOLDING NGG TTANK DATA DOUBLE CLEAN-OUTS Tank Type/Material STEP/STEEL Date installed 10/11-12/13 Tank size 1500 gal. Number of Compartments 2 Cleanouts (Y/N) YES Foundation cleanout (Y/N) 'NO Depression over tank (Y/N) NO High water alarm (YIN) YES Date of pumping 10/10/17 Pumper A+ HOME SERVICES C. ABSORPTION FIELD DATA 'BELOW EXISTING GRADE AT MT Date installed 10/11-12/13 Soil rating ..p.d./ 'or ft2/bdrm) 1.2 System type DUAL 5'WIDE Length 35/35 ft. Width 5/5 ft. Gravel below pipe 2.0/2.0 ft, Total depth '3.8+ ft. Eff. absorption area 500 ft2 Monitoring tube YES Depression over field NO Date of adequacy test 10/9/17 Results (Pass/Fail) PASS For 3 bedrooms Fluid depth in absorption field before test ''0 in. Water added •`610gal. New depth "0_in. Elapsed Time: '•0 min. Final fluid depth "0 in. Absorption rate >= 450+ g.p.d. Any rejuvenation treatment (past 12 mo ) (Y/N & type) NONE KNOWN If yes, give date - -1,059 GALLON PRE-SOAK PERFORMED ON SOUTH TRENCH 10/8/17 -1,022 GALLON PRE-SOAK PERFORMED ON NORTH TRENCH 10/8/17 '"WATER WAS INTRODUCED THROUGH LIFT STATION. MONITORING TUBES STAYED DRY THROUGHOUT TEST *SECOND COMPARTMENT OF OF 1500 GALLON STEP TANK "PER 2014 ELECTRICAL INSPECTION D. LIFT STATION Date installed 10/11-12/13 Size in gallons *500 Manhole/Access (YIN) YES "Pump on"level at 50 in. "Pump off' level at 46 in. High water alarm level at ss in. Datum BOTTOM OF LIFT STATION Cycles tested 3 Meets alarm & circuit requirements? "YES E. SEPARATION DISTANCES SEPARATION DISTANCES FROM WELL ON LOT TO: Septic tank/lift station on lot 100'+ On adjacent lots '100'+ (WITH CAVEAT) Absorption field on lot 100+ On adjacent lots '100'+(WITH CAVEAT) Public sewer main 75'+ Public sewer manholelcleanout 100'+ Sewer/septic service line 25'+ Holding tank 75'+ Animal containment areas 50'+ Manure/animal excrete storage areas 100'+ SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundation 5'+ Property line 5'+ Absorption field 5'+ Water main 10'+ Water service line 10'+ Surface water 100'+ Wells on adjacent lots 100'+ SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line 10'+ Building foundation 10'+ Water main 10'+ Water service line 10'+ Surface water 100'+ Driveway, parking/vehicle storage 10'+ Curtain drain NONE KNOWN Wells on adjacent lots 100'+ F. COMMENTS 'MEASURED 111'FEET TO ONLY SEPTIC SYSTEM PIPE THAT WE COULD FIND ON T12N R3W, SECTION 27: LOT 60A. PER OWNER OF LOT 60A THE DRAINFIELD EXTENDS TOWARDS THE NORTHWEST END OF THE PROPERTY. NO OTHER SEPTIC SYSTEM PIPES OBSERVED ♦•`G OF ` 1,4f G. ENGINEER'S CERTIFICATION I certify that I have determined through field inspections and 4' I• /` •- • review of Municipal records that the above systems are in • conformance with MOA COSA guidelines in effect on this :•••• •• ; date. •• J1 fl:I Garn.ss:: Engineer's Printed Name JEFFREY A. GARNESS O•• <<" • ,)a)'lc �•': Date / *h `7110_ 0\Alx 11 � / LICENSE• a11aIEsSt�444 $AECC884 (Rev. 10/12112)