Loading...
HomeMy WebLinkAboutRABBIT CREEK VIEW & HEIGHTS BLK 8H LT 8ARabbit Creek View & Heights Block 8H Lot 8A #020-561-50 MUNICIPALITY OF ANCHORAGE On -Site Water & Wastewater Program PO Box 196650 4700 Elmore Road Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997 http://www.muni.org/onsite On -Site Water & Wastewater System Permit Permit Number: OSP221238 Work Type: WellSeptic Initial Effective slate: Expiration Date: Tax Code Number: 02056150000 Site Legal Address: RABBIT CREEK VIEW & HEIGHTS BLK 8H LT8A G:3341 Site Mailing Address: 8300 Byron DR, Anchorage Owner: EDWARDS JACQUELINE ELIZABETH Design Engineer: FIRST WATER CONSULTING This permit is for the construction of: 2 Disposal Field Q Septic Tank ❑ Holding Tank ❑ Privy �ri,ent S U D epartInell t 8/17/2022 8/17/2023 Lot Size in Sq Ft: 32943 Total Bedrooms: 3 Q Private Well ❑ Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (2417). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing Received By: Issued By: Date: 8/17/2022 Date: -L ��I�UMUPAUTY OF '� HC HO ,AGE Development Services Department Phone: 907-343-7904 On -Site Water & Wastewater Section Fax: 907-343-7997 ON-SITE SEPTIC/WELL PERMIT APPLICATION Parcel I.D. 020- 561-50 Property owner(s) JACQUELINE EDWARDS Day phone Mailing address 8300 BYRON DRIVE, ANCHORAGE, AK 99516 Site address 8300 BYRON DRIVE, ANCHORAGE, AK 99516 Legal description (Sub'd., Block & Lot) RABBIT CREEK VIEW & HEIGHTS BLK 8H LT 8A Legal description (Township, Range & Section) Lot Size 32,943 Sq. Ft. Number of Bedrooms 3 APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (® all that apply) Absorption Field 0 Initial 0 Single Family (SF) El ADU) Septic Tank E Upgrade El(w/wo (D) El Holding Tank ❑ RenewalDuplex ❑ Multiple Dwellings ❑ Privy ❑ (SF and/or D) Private Well 0 Water Storage ❑ THIS APPLICATION INCLUDES A WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit/Rush Fees: 11� 8 2 b Date of Payment: 71617 -7 - Receipt Number: :9 Permit No. 1 Q31S Waiver Fees: Date of Payment: Receipt Number: Waiver No. GADevelopment Services\Building Safety\On Site Water and Wastewater\Forms\Client Forms\Permit Application.doc 13021 Montego Circle, Anchorage, AK 99516 907-350-9566 / FirstWaterAK@gmail.com July 8, 2022 Municipalities of Anchorage On-Site Water & Wastewater Program 4700 Elmore Road Anchorage, AK 99507 RE: SEPTIC SYSTEM UPGRADE PERMIT - ADVANTEX LEGAL: RABBIT CREEK VIEW & HEIGHTS BLOCK 8H & LOT 8A PHYSICAL: 8300 BYRON DRIVE, ANCHORAGE, AK 99516 The owner has requested a new septic field has and well to serve the 3BR residence. A sieve anlyis hasb been take due to the area and encroaching groundwater. The area has various CAT III systems (Advantex & Quanic) and we respectfully request an on-site well and septic permit to service the above referenced lot. We propose to install a shallow trench to be mounded with an Advantex system to serve the 3 -bedroom residence. The design is based on the recent test hole and sieve analysis conducted on this past month in June, 2022. The slopes are moderate at 5% at the proposed septic location. The lot and area are served by private water and septic as noted previously and on design. The design will not impact any of the neighboring properties. Please contact us if you have any questions. Sincerely, Curtis Huffman, P.E. Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP221238, Deb Wockenfuss, 08/17/22 FIRST WATER CONSULTING DESIGN CALCS: SUBJECT & ADJ PROPERTIES ARE SERVED OR PERMITTED W/ CAT/AX SEPTIC SYSTEMS & WELLS ARE 50'+ TO AX SEPTIC SYSTEM. NO SLOPES >25% WITHIN 50' OF PROPOSED FIELD. RABBIT VIEW & ESTATES BLK 8H LT 8A PES-AX SYSTEM 50'+ TO PROPOSED SUBJECT WELL AX SEPTIC MOUND WELL APPROX WELLS ALONG BYRON DRIVE NORTH OF PROPERTY ON OTHER SIDE OF STREET & SURFACE WATER FLOW IN THE EXISTING DITCH AS NOTED. Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP221238, Deb Wockenfuss, 08/17/22 FIRST WATER CONSULTING RABBIT VIEW & ESTATES BLK 8H LT 8A DESIGN DETAILS: Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP221238, Deb Wockenfuss, 08/17/22 13030 Sues Way - Anchorage, Alaska 99516 Tel. 907-350-9566 firstwaterAK@gmail.com SOILS LOG - PERCOLATION TEST LEGAL : RABBIT CREEK VW. & HTS B8H, L8A PERFORMED BY: FWC - I CURTIS HUFFMAN CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE & MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: 8/15/2022 DEPTH FEET OG SOILS 1 2 ORG/OL/FILL 3 4 5 6 GM/gp – 150 SOILS 7 8 SIEVE SAMPLE 9 GP-GM SOILS PER 10 SAMPLE 11 BOH 12 13 14 FYI: WETTEST AUGUST TD. 15 16 17 USE SLOWER PERC RATE. 18 19 20 Reading Date Gross Time Net Time Depth to Water Net Drop 8/4/22 10 min 6” 2 2/16” “ 6” 2 3/16” “ 6” 2 2/16” “ 6” 2 1/16” “ 6” 2 2/16” “ 6” 2 1/16” PERCOLATION RATE 4.8 (MIN / INCH) TEST RUN BEWTWEEN 3 & 4 FT PERC HOLE DIAMETER 6” PRE-SOAKED PRIOR TO TEST & ALL READINGS TO THE 1/16TH. GROUND WATER ENCOUNTERED: YES IF YES, AT WHAT DEPTH: 8’ W/ SEEPS DEPTH TO WATER AT MONITORING: 4.7’ DATE: 6/18/22 – FOUND AT 4’ 8/11/2022 – USE 4’ OR < TESTHOLE # 22-1 DATE PERFORMED: 6/8/22 SEE SITE PLAN FOR SLOPE & LOCATION COMMENTS: MOIST PERC – SEE BELOW. SIEVE SAMPLE AT 7’ INSTALL AX MOUND AT GRADE WITH SOIL & VEGETATION. MUST VERIFY GROUNDWATER / MT AT TIME OF CONSTRUCTION – ADD 2.5’+ OF MOA SAND RECOMMEND INSTALLING BOTH TRENCHES. PERFORMED FOR: JACQUELINE EDWARDS 8/15/22 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP221238, Deb Wockenfuss, 08/17/22 % GRAVEL 50.9 USCS GP-GM % SAND 38.2 USACOE FC N/A % SILT/CLAY 10.9 % PASS. 0.02 mm N/A % MOIST. CONTENT 7.7 % PASS. 0.002 mm N/A N/A N/A N/A SIEVE SIEVE TOTAL % SPECIFICATION SIZE (mm) SIZE (U.S.) PASSING (% PASSING) 152.40 6" 76.20 3"100 38.10 1.5"77 19.00 3/4"71 12.70 1/2"64 9.50 3/8"60 4.75 #4 49 2.00 #10 38 0.85 #20 29 0.43 #40 23 0.25 #60 18 0.15 #100 15 0.075 #200 10.9 ELAPSED DIAMETER TIME (MIN)(mm) 0 1 2 5 8 15 30 60 250 1440 SOUNDNESS OF AGG. (ASTM C88) DEGRADATION (ATM T-313) LA ABRASION (ASTM C131/C535) SP. GRAV. COARSE AGG. (ASTM C127) 11301 Olive Lane ∙ Anchorage, Alaska 99515 ∙ Phone: 907-344-5934 ∙ Fax: 907-344-5993 ∙ www.nge-tft.com N/A N/A The testing services reported herein have been performed to recognized industry standards, unless otherwise noted. No other warranty is made. Should engineering interpretation or opinion be required, NGE-TFT will provide upon written request. N/A HYDROMETER RESULT N/A SIEVE ANALYSIS RESULT Byron Street 6390-22 Grab @ 7' 22-S-1 Poorly-graded gravel w/ silt and sand 6/10/2022 Erik Boatwright Andrew Fortt TOTAL % PASSING UNKNOWN UNKNOWN First Water Consulting ServicesPROJECT CLIENT: PROJECT NAME: PROJECT NO.: SAMPLE DESC.: NGE-TFT ID #: CLASSIFICATION: DATE RECEIVED: TESTED BY: REVIEWED BY: UNIFORMITY COEFFICIENT (Cu) COEFFICIENT OF GRADATION (Cc) ASTM D1557 (uncorrected) ASTM D4718 (corrected) OPTIMUM MOIST. CONTENT. (corrected) 115 120 125 130 135 140 145 0 2 4 6 8 10 12 14 16DRY DENSITY (pcf)MOISTURE CONTENT (%) MOISTURE-DENSITY RELATIONSHIP ASTM D1557 SILT or CLAYCOBBLES GRAVEL Coarse Fine SAND Coarse Medium Fine 0 10 20 30 40 50 60 70 80 90 100 0.0010.01 0.11 10 100 FINER BY MASS (%)GRAIN SIZE (mm) PARTICLE SIZE ANALYSIS ASTM D6913 / C136 / D422 #200#40 #10 1.5 1/2 3 6 3/4 #4 #20 #60 #100 3/8 U.S. SIEVE OPENING IN INCHES U.S. SIEVE NUMBERS HYDROMETER Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP221238, Deb Wockenfuss, 08/17/22 � ANCHORAGE RECORDING DISTRICT,, ALASKA AS -BUILT OF: RABBIT CREEK VIEW & HGTS REPLAT LOT 8A BLOCK 8H PLAT 2004-91 SURVEY CERTIFICATE: 1, John L. Schuller, Have conducted a physical survey of this property as shown on this drawing and that the improvements situated hereon are within the property lines and no enchroachments exist other than noted. Under no circumstance shouli any information on this drawing be used for construction of fences, structures, improvements, or for establishing boundary lines. EXCLUSION NOTES: It is the owners responsibility to cletermine the existence of any easements, covenants, or restrictions which do not appear on the recorded subdivision plat. WORK ORDER NUMBER: DA' _E* SCAI-E. E-MAIL JUNE 16, 2022 1 "=40' schuller0ok.net 2 2 —059 DRAWN BY: CHECKED BY. GRID NUMBER: Boo#c Ate JLS SW3341 220228 LOT 9B BLK 8H 1-1 — 39 9p .1 (015" 2 = FND 5/8" REBAR 'M�XxxV�� Sup W O.Fl ..,4 LANZV) 0 �► OP 4L, /,•� 49TH-� �.......... ......... 7 Cn ........ ..-.. ............... C -.j N L. SCHULLER: 0 V LS -10408 1831 Talkeetna Street 1 p,. 6 Anchorage, Alaska 99508 f �\'MAWW essionc\ (907) 227-1455 office (907) 274-4992 f ax MUNICIPALITY OF ANCHORAGE Development Services Department Phone: 907-343-7904 On-Site Water & Wastewater Section Fax: 907-343-7997 Mailing Address: P. O. Box 196650 * Anchorage, Alaska 99519-6650 * www.muni.org Septic System Owner-installer Agreement The On-site Water and Wastewater Section (On-site) may issue an approval for a homeowner to perform work on an on-site wastewater disposal system to serve that individual's owner- occupied, single-family or duplex home if the homeowner meets and agrees to the following requirements: 1. The property owner and excavation equipment operator may perform work on no more than one owner-installation project in a 12-month period. 2. Owner’s projected active involvement with the installation: _______________________________________________________________________ _______________________________________________________________________ 3. The name of the excavation equipment operator: ________________________________ 4. I agree that there will be no monetary compensation for installation services rendered. 5. The name of the inspecting engineer: _________________________________________ 6. I agree to discuss the following items with the inspecting engineer: a. Permit design criteria and specifications. b. Inspection requirements set forth in AMC 15.65.070. c. Advance notice given to the On-site Water & Wastewater Section for all required municipal inspections (AMC 15.65.070A). 7. I agree to have the project-specific On-site Wastewater Disposal System Permit available at the construction site for the duration of all related work. 8. I agree that if the system is an advanced wastewater treatment system (AWWTS), I will obtain additional installation instructions and approval from the equipment distributor. As owner of (legal description) ________________________________________________ I agree that the information above is true and accurate. Owner’s printed name: _________________________ Owner’s signature: _________________________ Date: ________________ MUNICIPALITY OF ANCHORAGE ADVANCED WASTEWATER TREATMENT SYSTEM MAINTENANCE AND REPAIR AGREEMENT THIS MAINTENANCE AND REPAIR. AGREEMENT, herein the "AGREEMENT" made and entered into as of this Day of AQ C-iQ sT of 20 22 , by and between dc" E-LiN EDwAcj��S , herein the "OWNER," and the Municipality of Anchorage, herein the "MUNICIPALITY", in accordance with Anchorage Municipal Code (AMC) 15.65.365. In consideration of the mutual covenants contained herein, the parties to this Agreement agree as follows: L Advanced Wastewater Treatment 4zv,.tems. The Municipality grants permission to the Owner to utilize and operate an Advanced Wastewater Treatment System (AWWTS), described as AN ADVANTEX SYSTEM located at (legal description) RABBIT CREEK VIEW & HEIGHTS B8H, L8A 2. Maintenance, Repairs and Alterations. (Owner is required to read, understand and initial each section) Throughout the term of this Agreement, the Owner shall enter into a service agreement with an AWWTS service and maintenance provider approved by the Municipality or the manufacturer's representative. The AWWTS shall be maintained in a satisfactory condition capable of performing as designed and producing treated septic effluent in accordance with the equipment's approval for operation in the Municipality. It shall be the responsibility of the Owner during the term of this Agreement to pay for all repair(s), maintenance, adjustment(s), replacement costs, and inspection costs. This includes an annual maintenance fee (typically $400 to $600). Owner agrees that only maintenance and repair personnel approved by the Municipality or the manufacturer's representative will inspect and make any necessary maintenance, repairs or permitted alterations to the system. L Owner acknowledges that regular maintenance of an AWWTS reduces the potential failure of the system, which could include sewage backup and costly repairs or drainfield replacement. (rev. 05/18/2018) Page 1 of 3 WA::- Owner acknowledges that the Municipality may request records of maintenance and repairs from the manufacturer's representative or maintenance provider. Owner acknowledges that the fine for failing to maintain and repair an AWWTS may be assessed in accordance with AMC 14.60.030. ��Owner agrees to grant the Municipality reasonable access to test and inspect the AWWTS. The Municipality will give at least 24-hour notice. 4L__Owner agrees that any sale or transfer of title of the property will not occur without a new Certificate of On -Site Systems Approval. '_ t .-Owner agrees that the AWWTS installation and maintenance requirements as provided by the AWWTS vendor/installer and approved by the Municipality are the governing guidelines for the construction, maintenance and repair of the Owner's AWWTS. wner agrees to maintain remote monitoring of the AWWTS as required by the AWWTS approval. 3. Term. The term of this Agreement shall begin on the date of approval by the Municipality to operate the installed system, or upon transfer of title, and shall continue while the AWWTS is operational or until title is transferred. 4. Nonwaiver. The failure of the Municipality at any time to enforce a provision of this Agreement shall in no way constitute a waiver of the provisions, nor in any way affect the validity of the Agreement or any part hereof, or the right of the Municipality thereafter to enforce every provision hereof. 5. Amendment. This Agreement shall only be amended by authorized representatives of the Owner and Municipality. Any attempt to amend this agreement by either an unauthorized representative or unauthorized means shall be void. 6. Jurisdiction: Choice of Law. Any civil action arising from this Agreement shall be brought in the Superior Court for the Third Judicial District of the State of Alaska at Anchorage. The laws of the State of Alaska shall govern the rights and obligations of the parties under this Agreement. 7. Severability. Any provisions of this Agreement decreed invalid by a court of competent jurisdiction shall not invalidate the remaining provisions of the Agreement. (rev. 05/18/2018) Page 2 of 3 4R: (signature) Date: B: z2 '`►A;; Lr "'�1����irt-ps (print name) STATE OF ALASKA ) ) ss. TBIRD JUDICIAL DISTRICT ) The foregoing instrument was acknow edged before me this day of 204'Q,by �.�ss3.�J%n,e— (� &We ofAkuka NOTARY PUBLIC_ FOR ALA KA _ NOTARY PUBLIC My Commission expires: _p3hq l abQL, Jeremiah D. Rid away My Commla m ores 03 I} MUNICIPALITY• By: (signature) (print name) Date: Title: (rev. 05/18/2018) Page 3 of 3 Permit Number: Tax Code Number: Work Type: On-Site Wastewater Disposal System Permit OSP131413 02056150000 Septic MUNICIPALITY OF ANCHORAGE Development Services Department On-Site Water & Wastewater Program 4700 Elmore Road, PO Box 196650 Anchorage, AK 99519-6650 Telephone: (907) 343-7904 Permit Effective Dates: November 01, 2013 to November 01,2014 Design Engineer: Subdivision: RABBIT CREEK VIEW & HEIGHTS Site LegalAddress: RABBIT CREEKVIEW & HEIGHTS BLK 8H LT 8A G:3341 Owner/Address: EDWARDS JACQUELINE ELIZABETH 900 W 5TH AVE ¢f-403 ANCHORAGE AK 995010000 Site Mailing Address: 8300 Byron DR, Anchorage Lot Size in Sq Ft: 32943 Total Bedrooms: 1 This permit is for the construction of: N Disposal Field N Septic Tank N Holding Tank Y Privy N'PrivateWell N Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80). 3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either: A. Open and Close on the same day. B. Covered, sealed, and heated to prevent freezing. Special Provisions: Final inspection report and asbuilt drawings shall be submitted prior to operational approval. Special Provisions: The tank (vault) installation is required to be inspected after the tank is placed, but prior to backfilling. The Department shall be notified at least two hours prior to any inspection. Received By: MUNICIPALITY OF ANCHORAGE Community Development Department Development Services Division On-Site Water & Wastewater Program Phone: 907-343-7904 Fax: 907-343-7997 ON-SITE SEWER/WELL PERMIT APPLICATION Parcel I.D. 0205615000001 Property owner(s) Jacqueline Edwards Mailing address P.O. Box 200032 Anchorage, AK, 99520 Day phone (208) 553-9112 Site address 8300 Byron Drive Legal description (Sub'd., Block & Lot) Rabbit Creek View and Heights. B8H L8A Legal description (Township, Range & Section) Lot Size 32,943 Sq. Ft. Number of Bedrooms O APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: ([~ all that apply) Absorption Field [] Initial [] Single Family (SF) [] (w/wo ADU) Septic Tank [] Upgrade [] Duplex (D) [] Holding Tank [] Renewal [] Multiple Dwellings [] Privy [] (SF and/or D) Private Well [] Water Storage [] THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with a~ble Municipal Codes. (SignatUre ~f ~-r~pen~owner or authorized agent) Permit/Rush Fees: Date of Payment: Receipt Number: Permit NO. Waiver Fees: Date of payment: Receipt Number: Waiver No. Permit App_9-1-12.doc To: James A. Crewdson Re: Vault privy Mr. Crewdson. It has been a pleasure working with you towards finding a resolution in our home building goals. We have spoken over the phone a few times, and we have decided that a vault privy will work the best for us now. We plan for now to build a cabin on our land, and as the vault privy, we intend to use the steel ~.2 gauge tank from Anchorage Tank model number AT:[500S. This tank has been approved by the municipality, and will suit our vault privy requirements, as well as providing the properly sized tank to support our future plans of building a five bedroom home on the property. We do realize that the tank we buy now and which will be used as the vault priw chamber will need to be moved eventually, according to engineered plans, based upon future septic design. This will be no problem, and it is what we desire to do. For now we will have a simple cabin, and will only be turning in that part of the home design, as it is what we are seeking approval for, and it is likewise what will be built. There are no wells within 200' of the vault privy that we have located on the design. Thank you again for working with us. We look forward to completing this process, and thank you for your time. Sincerely, ~u~& Jacqu,,eline Edwards