Inspection Report_t-1- .riot
Municipality of Anchorage
Community Development Department Page 1 of 3
On-Site Water and Wastewater Program
4700 Elmore St. • P.O. Box 196650 Anchorage, AK 99519-6650 • http://www.muni.org/onsite • (907) 343-7904
ON-SITE
WASTEWATER INSPECTION REPORT
Permit Number: OSPI31410
PID Number: 051-324-09 Z New ❑ Upgrade
Name:
Troy Davis Homes
ABSORPTION FIELD
❑ Deep Trench 0 Shallow Trench ❑ Bed ❑ Mound
Address
165 E. Parks Highway, Wasilla, AK 99654
❑ Other
Phone
Number of Bedrooms
Soil Rating
Total depth from original grade
357-9394
3
•BGPDISF
5 Ft.
LEGAL DESCRIPTION
Depth to pipe invert from original grade
2.5 Ft.
Gravel depth beneath pipe
2.5 Ft.
Subdivision
Block Lot
Recreation Center
Tr B1
Fill added above original grade
1-2 Ft,
Gravel length
72 Ft.
Township Range Section
Gravel width
5Ft.
Beds: Number of Lines
Distance between lines
I Ft.
SEPARATION DISTANCES
To
Septic
Absorption
Holding
Sewer
Total absorption area
Number of trenches
Dist. between trenches
From
Tank
Field
Lift Station
Tank
Line
562.5W
Two
I >10Ft.
Well
>100'
>100'
N/A
NIA
>25,
TANK p Septic ❑ S.T.E.P. ❑ Holding ❑ Other
Manufacturer
Anchorage Tank
Capacity
1,OOOGal.
Surface water
>100'
>100'
N/A
N/A
Material
Steel
Number of compartments
Two
Lot Line
>5'
>10'
N/A
N/A
NA
Foundation
>5'
>10'
N/A
NIA
LIFT STATION
Manufacturer
Capacity
Gal.
Curtain Drain
None
Noted
Pump on level at
Pump off level at
High water alar at
RemarksGinder Pump Lift Station is Located in the
in.
in.
in.
Crawl Space in the House.
Pump make and model
Electrical Inspections performed by
PIPE MATERIAL Housetotank D3034 Tank to D3034
drainfield
Installer
Northern Excavation
Drainfield HDPE CO/MT D3034
Inspector AH
BENCHMARK (Assumed elevation) 100.Oft
Inspectionr
I 11/15/13
d 11/16/13
Location and description
dates:
2
Garage Slab NE Corner.
3"
a'"
COMMUNITY DEVELOPMENT DEPARTMENT APPROVAL
Eq OF jqI '
q1�
�� P�E,.....:4.,<
V •�
Conditional Approval:
Date
're • *••:
M *: 49
0/•[y.• ' b o• •.. owou
.MICHAEL. E ANDERSON
CE-4381
t,��►
Approved
Date
E ���►�
Inspection Report_t-1- .riot
Municipality of Anchorage
Permit Number: OSP131410 DEVEOPMENT SERVICES DEPARTMENT
4700 South Bragaw Street Anchorage, AK. 99519-6655 - 343-7904
Page 2 of 3
PID No. 051-324-09
15' SCREENING EASEMENT
S89.57'15"E 551.12
TRACT B1CENT
,RECREATION
SUBDIVISION (85-82)
PROPOSED LOT 2
HORIZON ESTATES
40,026 sq.ft.
J
J
Well ®
J
N
N
0
O
0
0
1L
d
ALTERNATE SITE
Advontex Treatment System with 15'
Long x 5' Wide x 4' Effective Depth
Absorption Trench. 4 GPD/SF
Absorption Rate,
B C
Si 21.6' 24.8'
S2 20.9' 30.6'
C4 1 18.5' 41.1'
C5 37.8' 30.8'
M1 16.2 43.4
Lift
Station
8
M2 37.2' 31.2' -
Three Bedroom S1
FSV 20.7' 46.3'
Home S2
C6 34.1' 52.3'
C7 53.4' 48.9'
® C4 FSV
M3 31.9' 50.0'
Mi
M4 51.8' 50.0'
/
C6
/ ®M�
.:e... Alt.
Site 2 /
C5
/M4
07
15' SCREENING
EASEMENT
---------------
----------------- --N89'57'W''W..41-4.45-____
-_-_--- -
•���•'+OF •
�♦i
P
o
•O�P*""""A�
MULDROW STREET
••`•♦♦
s.....:: 49th
LEGEND
............
�
MT - Monitor Tube
4
............... �'/
' MICHAEL E. ANDERSDN•�,
SITE PLAN
FCO - Foundation Clean Out
CO -Test Hole
CO -Clean Out
•♦ f••.• No. CE-4381 !
FSV now Splitter Valve
ti,
..
♦�♦��
'•?;Z .......
�1�111YA
SCALE V = 40'
FES;= iO�
Municipality of Anchorage
DEVEOPMENT SERVICES DEPARTMENT
4700 Elmore Road Anchorage, AK. 99519-6655 - 343-7904
On -Site Wastewater Disposal System or Well Inspection Report
Permit Number: OSP131410
y 105.3
012 1,000 Gallon
Septic Tank J
7u1 1
10/3.4
Finished G.d.
Page 3 of 3
PID No. 051-324-09
�U
100.0
97.5—/ v Groundwater @ 92.9
10-16-13
88.5
101.2
987 QGroundwater@92.9
88.5 10-16-13
U g
N
2
H
7
97.5--/
�U
Drainfield Rock
100.0
97.5—/ v Groundwater @ 92.9
10-16-13
88.5
101.2
987 QGroundwater@92.9
88.5 10-16-13
U g
N
2
H
7
97.5--/
�U
PROFILE AS -BUILT -
No Scale
98.7--/
------101.2
8.7--
00.0
----101.2
Drainfield Rock
PROFILE AS -BUILT -
No Scale
98.7--/
------101.2
8.7--
00.0
----101.2
ACE WATER WELL DRILLING
A subsidiary ofACE Ventures, Inc.
P.O. Box 520090
1167 N. Knapp Dr
Big Lake, Ak. 99652
(907) 357-7987 fax (907) 376-7987 (907) 354-1398 cell
Well Owner: Troy Davis Homes
Location: Lot 2 Horizon —18105 Muldrow St, Eagle River
Date of Completion: 12-11-2013 Job # 13- 57
Use of Well: Domestic
05P�7/51410
/�ccrca,}tbn (en-te, Tr Bl
Drilling Method: Air Rotary
Size of Casing: 6" Depth of hole: 225 feet Cased to: 92 feet
Static Water Level: 15 feet below top of casing.
Finish of Well ( ) Open End { ) Grout/Sea] ( ) Screen/Liner ( X ) Perforated
Describe screen, seal, or perforation: Perforated 40 to 42 feet
Well Pumping Test at 4 Gallons per ( ) hour ( X ) minute.
Suggested Pump setting depth: 215 feet from top of casing.
Method of disinfection: Chlorine tablets
Depth in feet from casing
top
Details of Formations/size/color/ etc
0 to 2 feet
Stick up
2 to 38 feet
Silty sandy gravel
38 to 42 feet
Sandy gravel — dirty silty water
42 to 70 feet
Clayey gravel
70 to 225 feet
Bedrock
O
Driller Signatur Date: ' L —
Ace Water Wells
P 0 Box 520090
Big Lake, Ak. 99652
(907)376-7997
lane et
ME:=
Well Owner: Troy Davis Homes Job# PO4-29-14
Installation Date: 04/29/2014
Legal Description: Lot 2 Horizon Estates, Eagle River
Nlmamf �
Pump Manufacturer: Goulds
Model; Bruiser
Slze: I Horse
feet below top of casing (TOC).
Disinfection method: Chlorine tablets
Well Depth: 200'
Static: 17'Below T,O,C.
Additional comments, 4 gpin flow restrictor installed with purnp,
Installer signature ✓
Date
V i�f
On -Site Water & Wastewater System Permit
MUNICIPALITY OF ANCHORAGE
Development Services Department
On -Site Water & Wastewater Program
4700 Elmore Road, PO Box 196650
Anchorage, AK 99519-6650
Telephone: (907) 343-7904
Permit Number: OSP131410
Tax Code Number: 05132409000
Work Type: WellSeptic
Permit Effective Dates: November 08, 2013 to November 08, 2014
Design Engineer: ANDERSON ENGINEERING
Subdivision: RECREATION CENTER
Site Legal Address: RECREATION CENTER TR B1 G:0553
Owner/Address: TROY DAVIS HOMES INC
165 E PARKS HWY STE 200 WASILLA AK 996547059
Site Mailing Address: 18105 MULDROW ST, Eagle River
This permit is for the construction of:
Y Disposal Field Y Septic Tank N Holding Tank
Lot Size in Sq Ft: 161223
Total Bedrooms: 4
N Privy Y Private Well N Water Storage
/2, oa
All construction must be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater
Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80).
3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services
Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either:
A. Open and Close on the same day.
B. Covered, sealed, and heated to prevent freezing.
Received
Issued By
co i rt v'.SeS 4.tiQ &N1, 4 t IA
MUNICIPALITY OF ANCHORAGE
Community Development Department
Development Services Division
On -Site Water & Wastewater Program
Phone: 907-343-7904
Fax: 907-343-7997
ON-SITE SEWER/WELL PERMIT APPLICATION
Parcel I.D. 051-324-09
Property owner(s) Troy Davis Homes Day phone
Mailing address 165 E. Parks Highway #200 Wasilla, AK 99654
Site address 18311 Muldrow Street Eagle River, AK 99577
Legal description (Sub'd., Block & Lot) Recreation Center, Tract 131
Legal description (Township, Range & Section)
Number of Bedrooms Four
Lot Size 161,223 Sq. Ft.
APPLICATION IS FOR:
(0 all that apply)
Absorption Field
❑X
Septic Tank
❑X
Holding Tank
❑
Privy
❑
Private Well
❑X
Water Storage
❑
APPLICATION IS AN:
Initial
❑X
Upgrade
❑
Renewal
❑
310-2501
TYPE OF DWELLING:
Single Family (SF) ❑X
(w/wo ADU)
Duplex (D) ❑
Multiple Dwellings ❑
(SF and/or D)
THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR:
Distance:
I certify that the above information is correct. I further certify that this is in accordance with
applicable Municipal Codes.
(Signature of property owner or authorized agent)
Permit/Rush Fees: 5:30 O' Waiver Fees:
Date of Payment: (01a,015 Date of Payment:
Receipt Number: OCCR i C1 Receipt Number:
Permit No. 05fj�I%410 Waiver No.
Permit App_::. :L..k.
October 26, 2013
Municipality of Anchorage
Development Services Department
On -Site Water and Wastewater Program
4700 South Bragaw Street
Anchorage, AK 99519-6650
Subject: Tract B1, Recreation Center Subdivision
Septic System Design and Permit Application
Impacts to Adjacent Properties
Dear Onsite Services Engineer:
The owner of Tract 131, Recreation Center Subdivision intends to construct a new four-
bedroom home on the lot. The tract is currently proposed for subdivision into several
lots and the location shown will eventually be Lot 2 of Horizon Estates Subdivision. We
are requesting a permit be issued on the entire tract for the construction of a new well
and septic system to accommodate the home. The attached Site Plan and backup
documentation identify the location and configuration of the proposed well and septic
system along with the alternate site. Also identified on the plans are the proposed wells
in the area and septic systems on surrounding lots. No conflicts exist between the
proposed septic system and well or septic systems and wells on adjacent lots.
Drainage arrows are shown on the site plan showing the grade and direction of flow on
the lot. The drainage pattern will not be changed as a result of this project.
The test holes placed on the lot indicated silty sand with gravel (SM/GM). The
percolation rate of the soil was determined to be 9 to 10 minutes per inch.
Groundwater was found during the placement of the test holes and stabilized during the
monitoring period at 9.6' below the surface at Test Hole No. 14. An application rate of
.8 gallons per day per square foot was used in the design of the absorption system.
We are proposing to place a new 1,250 -gallon septic tank and 2-38' long by 5' wide by
4' effective depth absorption trenches to treat and dispose of the effluent generated in
the house. The elevation of the distribution line in the absorption trenches will be 1.5'
below the surface and the total depth will be 4.5'. A minimum of 3' of fill or 2" of
insulation and 2' of fill will be placed over the absorption trench and 4' over the septic
tank.
The ground surface on the lot in the area of the septic system slopes to the southeast
at a shallow grade with some cross sloping from the east. The new trencheswillbe
constructed parallel with the contours of the slope as much as possible in conformance
with Municipal requirements. The new septic system will be constructed a minimum of
100' from all wells and any surface water and 10' the proposed and existing water
Tract B1, Recreation Center
October 26, 2013
Page Two
services in the area.
If the system is constructed in accordance with our design the following statements
apply:
1. The system, if constructed as designed, will have no adverse impact on the wells
in the area or those to be constructed in the future.
2. The system, if constructed as designed, will have no adverse impact on existing
septic systems in the area or those to be constructed in the future.
3. The system, if constructed as designed, will have no adverse impact on reserve
space, either surface or subsurface, on any lots located in the area.
4. The system, if constructed as designed, will have no adverse impact on drainage
patterns in the area. The current drainage pattern will be maintained.
Sincerely,
L---7
Michael E. Anderson, P.E.
Attachments
w�
IV SyJbyl(9-60pZ� ~
.9 y07 dN D��e
I iavuz
,+t — --4 —S00'03-00" 6 300-11—
F
00.11—
I O'1N3,3Sd3 DNIN3380S .St - w�
o �
N W
U
Z
~ W
W V
N
N�
c
w h
E to
z
Cs7 02 I W Proposed Lot Line\
U co
z 1 \ Q
O
to N J
CID
p`
& 0
r
2`
WW
W
/ W
,-t Proposed Lot Line
Qa .�-
F I ice_/
U �
r6 w
yy U
w1N3N3SV3 ONIN33UDS X \
w ' N00'02'30"W 299.72
Nptsr an
nrp
o Z 8'l.7bgy NOfdb�ElOgt!
N
VNIdSVrIVW
15' SCREENING EASEMENT
NOTE:
No Areas of Excessive Slope or
Surface Water ore Within 100' of Any
Part of the New Septic System.
w
0
0
0
Cas
B1 RECREATION CENTER
SUBDIVISION (85-82)
PROPOSED LOT 2
HORIZON ESTATES
40,026 sq.ft.
Proposed
Well 40
a)
d
C
C
J
J
J
0
N
d
0
0
CL
0 -
ALTERNATE
ALTERNATE SIT
\ Advontex .Treatment System with 15
Long
Long z 5' Wide x 4' Effective Depth
Absorption Trench. 4 GPD/SF
\ Absorption Rote.
OTH13 I 1,250 Gallon `�_,._
FCO Septic Tank `\
Three Bedroom
Home I SV Alt. Site
_ I s�
SV ' 2CO 1t 60
—1: Sv w
® O 2-36' Long x 5' Wide
x 2.5' Effective Depth
�` Is Absorption Trenches
!'�I a, CO
R GO 46, 1'53
-Mm
15' SCREENING EASEMENT
N89'57'06"W 414.45
MULDROW STREET
SITE PLAN
SCALE V = 40'
LEGEN
MT - Monitor Tube
FCO - Foundation Clean Out
TH - Test Hole
CO - Clean Out
FSV - Flow Splitter Valve
TRACT B1 RECREATION CENTER
SUBDIVISION (85-82)
DESIGN FACTORS: SYSTEM REQUIREMENTS:
Three Bedroom Home
Perc. Rate: 9.6 Min./Inch
Application Rate: .8 GPD/SF
5' Wide Trench System
1,000 Gallon Septic Tank
2.5' Drainfield Rock
3 Bedrooms X 150 GPD/.8 GPD/SF (Application Rate) = 562.5 SF Absorption Area
562.5 SF/5SF/LF*.64 (Reduction Factor) = 72 LF Trench Length
THEREFORE: Construct 2-36' Long x 5' Wide x 2.5' Effective Depth Absorption Trenches at the
Location Shown. Flow Line Elevation in the Trenches to be 2.5' Below Original Ground. Total
Depth to Be 5.0' Below Existing Ground. Provide 4' of Cover Over Septic Tank and a Minimum of
3' Cover Over Absorpiton Trenches. Maintain 100' Separation from Wells in the Area.
Natural
Backfill
2'0" Geotextile
Fabric
6" O 4" Perforated
PVC (Holes Down)
2'6" 1 1 -------- -� Drainfield Rock
5'
5' WIDE TRENCH SECTION ....••_..�
(NO SCALE) 49th
NOTE: Grade Area Over Trench to Drain Away.
Minimum 6' Separation From Bedrock. i�
..y..•:.�.......,......� .........
Minimum 4' Separation From Groundwater. i
�.
Minimum 100' Separation From Wells in the Area. _................................ m ; MICHAEL E. ANDERSON
Minimum 100' Separation From Surface Water or Streams. �� s,:, No. CE.4381
E:
MUNICIPALITY OF ANCHORAGE
DEVELOPMENT SERVICES DEPARTMENT
4700 BRAGAW STREET ANCHORAGE, AK 99519-6650
DEPTH
(feet)
1-
2
3
4
5
6
7
9
10-
11
12-
13-
14-
15-
17
SOILS LOG - PERCOLATION TEST
LEGAL DESCRIPTION: LOT 2, HORIZON SUBDIVISION
PERFORMED FOR: TROY DAVIS HOMES
DATE: 10/11/13 PROJECT No.:
PARCEL ID#: TECHNICIAN: A. HARALA
TEST HOLE 14
0
OB/OG
SILTY GRAVEL
WITH SAND
a GM
BOH @ 14'
SLOPE
N
IR
49th •i
MICHAEL E. ANDERSON
No. CE -4381
Pmfemional
SITE PLAN
SEE SITE PLAN
1
WAS GROUND WATER ENCOUNTERED? YES
IF YES @ WHAT DEPTH? 9.6'
DEPTH OF WATER AFTER MONITORING: 9.6' 2%
DATE OF MONITORING: 10/16/13
DATE
READING
GROSS TIME
(MINUTES)
NET TIME
(MINUTES)
DEPTH TO
WATER
(INCHES)
NET DROP
(INCHES)
TEST HOLE PRESOAKED PRIOR TO TESTING:
10/11
1
10:25
2.6311
2
10:55
30
5.7511
3.12"
3
10:56
2.50"
4
11:26
30
5.6311
3.1311
5
11:27
2.6311
6
11:57
30
5.7511
3.1211
PERCOLATION RATE: 9.6 (MIN/INCH) PERC. HOLE DIA. 6" (INCHES)
TEST RUN BETWEEN: 3_5 FT. and 4_5 FT.
COMMENTS: TEST HOLE PRE SOAKED PRIOR TO TEST.
TEST PERFORMED BY ANDERSON ENGINEERING. I, MICHAEL E. ANDERSON CERTIFY THAT
THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPLE GUIDELINES IN EFFECT ON THIS
DATE: 10/20/13
MUNICIPALITY OF ANCHORAGE
DEVELOPMENT SERVICES DEPARTMENT
4700 BRAGAW STREET ANCHORAGE, AK 99519-6650
DEPTH
(feet)
1-
2
3
4
5
6
7
8
9
10-
11
12-
13-
14-
15-
16-
17 -
SOILS LOG - PERCOLATION TEST
LEGAL DESCRIPTION: LOT 2, HORIZON SUBDIVISION
PERFORMED FOR: TROY DAvIS HOMES
DATE: 10/11/13 PROJECT No.:
PARCEL ID#: TECHNICIAN: A. HARALA
TEST HOLE 13
OB/OG
a
SILTY GRAVEL
WITH SAND
d GM
SLOPE
N
0
.� 49th
MICHAEL E. ANDERSON
SITE PLAN
SEE SITE PLAN Y
4
a
WAS GROUND WATER ENCOUNTERED? YES
° IF YES @WHAT DEPTH? 6.5' S
DEPTH OF WATER AFTER MONITORING: 6.5' O 2%
DATE OF MONITORING: 10/16/13
a
a
BOH @ 14'
COMMENTS: TEST HOLE PRE SOAKED PRIOR TO
DATE
READING
GROSS TIME
(MINUTES)
NET TIME
(MINUTES)
To
DEPTH WATER
(INCHES)
NET DROP
(INCHES)
TEST HOLE PRESOAKED PRIOR TO TESTING:
10/11
1
10:07
3.2511
2
10:37
30
6.50"
3.0011
3
10:38
3.38"
4
11:08
30
6.3811
3.00"
5
11:09
3.25"
6
11:39
30
6.25"
3.00"
PERCOLATION RATE: 10 (MIN/INCH) PERC. HOLE DIA. 6�� (INCHES)
TEST RUN BETWEEN: 3_5 FT. and 4_5 FT.
TEST PERFORMED BY ANDERSON ENGINEERING. I, MICHAEL E. ANDERSON CERTIFY THAT
THIS WAS PERFORMED I_N ACCORDANCE WITH ALL STATE AND MUNICIPLE GUIDELINES IN EFFECT ON THIS
Ti ATF• 10/20/13
vc. U
• Municipality of Anchorage
On -Site Water and Wastewater Program.
40;- ' *64
(907)343-7904 ®
/# ; W
Certificate of On -Site Systems Approval
Parcel I.D. 051-324-09 Expiration Date:
1. GENERAL INFORMATION
Complete legal description Recreation Center, Tract 151
Location (site address) 18105 Muldrow Street Eagle River, AK 99577
Current Property owner(s) Troy Davis Homes, Inc. Day phone 357-9394
Mailing address 165 E. Parks Highway, No. 200 Wasilla, AK 99654
Real Estate Agent Day phone
2. TYPE OF DWELLING:
0 Single Family (w/wo ADU)
❑ Duplex
❑ Multiple Dwellings (Single Family and/or Duplex)
3. NUMBER OF BEDROOMS: Three
4. TYPE OF WATER SUPPLY:
TYPE OF WASTEWATER DISPOSAL:
Individual Well
I]
Individual
F]
Individual Water Storage
❑
Holding Tank
❑
Community Class Well
❑
Community
❑
Public Water System
❑
Public Sewer
❑
WaiverNariance request for:
Distance:
Received by:
Date:
';' �Y
COSA to be released to the engineer, unless otherwise
requested by the engineer.
COSA Fee $ Waiver Fee $
Date of Payment (,,''//��� Date of Payment
C/-�iii
Receipt Number "/ 16 Receipt Number
COSA# OSOgloggg Waiver#
5. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation,
based on pcoeedures outlined in the Certificate of On -Site Systems Approval Guidelines fol; this application,
shows that the on-site water supply and/or wastewater disposal system is (are) safe;,funetional and adequate
for the number of bedrooms and type of structure indicated herein. I further verify that based on the information
obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water
supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes,
ordinances, and regulations in effect at the time of installation.
Name of Firm Anderson Engineering Phone
Address P.O. Box 240773 Anchorage, AK 99524
Engineer's Printed Name Michael E. Anderson, P.E.
6. DSD SIGNATURE
System #1 Approved for bedrooms
System #2 Approved for bedrooms
Disapproved
Date
522-7773
Conditional approval for bedrooms, with the following stipulations:
By, � ��� �� Original Certificate Date: - - Z�
The IGiiiniciglt�AO�Worage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only
upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality
of Anchorage is not responsible for errors or omissions in the professional engineer's work.
7. ATTACHMENTS:
COSA Checklist X Nitrate Advisory
Septic System Advisory Arsenic Advisory
Well Flow Advisory Other
COSA blue sheet[ c
If more than 1 septic system is on the lot:
COSA Checklist # _of _
Structure served by this system
Certificate of On -Site Systems Approval Checklist
Legal Description: Recreation Center, Tract B1
A. WELL DATA
Well type Private If A, B, or C provide PWSID # _
Date completed 12/11 /13 Sanitary seal (Y/N) Y
Total depth 225 ft. Cased to 92 ft.
FROM WELL LOG
Date of test 12/11/13
Static water level 15 ft.
Well production 4 g.p.m.
WATER SAMPLE RESULTS:
Coliform 0 colonies/100 mL Nitrate .417 mg/L
Arsenic ND ug/L Date of sample: 5/5/14
B. SEPTIC/HOLDING TANK DATA
Tank Type/Material Septic/Steel
Tank size 1,000 gal. Number of Compartments 2
Foundation cleanout (YIN) Y Depression over tank (Y/N) N
Date of pumping New Const. Pumper
C. ABSORPTION FIELD DATA
Parcel ID: 051-324-09
Well Log (Y/N) Y
Wires properly protected (Y/N) Y
Casing height (above ground) >18 in.
AT INSPECTION
ft.
�Jffd
Collected by: Anderson Engrg.
Date installed 11/15/13
Cleanouts (Y/N)
High water alarm (Y/N)
Y
N
Date installed 11/16/13 Soil rating (g.p.d./ft2 or ftz/bdrm) .8 GPD/SF System type 5' Wide Trench
Length 2-36 ft. Width 5 ft. Gravel below pipe 2.5 ft.
Total depth 6-7 ft.- Eff. absorption area .562,5 ft2 Monitoring tube Y Depression over field N
Date of adequacy test New Const, Results (Pass/Fail) For _ bedrooms
Fluid depth in absorption field before test in. Water added gal. New depth in.
Elapsed Time: min. Final fluid depth in. Absorption rate >= g.p.d.
Any rejuvenation treatment (past 12 mo.) (Y/N & type) N If yes, give date
D. LIFT STATION
Date installed Size in gallons _
"Pump on" level at in. "Pump off' level at
Datum Cycles tested
Manhole/Access (Y/N)
in. High water alarm level at in.
Meets alarm & circuit requirements?
E. SEPARATION DISTANCES
WELL ON LOT TO:
Septic tank/lift station on lot > 100' On adjacent lots > 100'
Absorption field on lot >100' On adjacent lots >100'
Public sewer main N/A Public sewer manhole/cleanout _
Sewer /septic service line >25' Holding tank NIA
Animal containment areas >50' Manure/animal excrete storage areas >100'
SEPTIC/HOLDING TANK ON LOT TO:
Building foundation >5' Property line >5'
Water main >10' Water service line >10'
Wells on adjacent lots >100'
ABSORPTION FIELD ON LOTTO:
Property line >10 Building foundation >10'
Water Service line >10' Surfacewater >100'
Curtain drain None Noted Wells on adjacent lots >100'
N/A
F. COMMENTS
House has interior grinder pump and lift station.
G. ENGINEER'S CERTIFICATION
I certify that I have determined through field inspections and
review of Municipal records that the above systems are in
conformance with MOA COSA guidelines in effect on this date.
Engineer's Printed Name Michael E. Anderson, P.E.
Date 7/2/14
COSA brawn sheet 10-10-12.dac
Absorption field >5'
Surface water >100'
Water main N/A
Driveway, parkinglvehicle storage > 10'
20' UTILITY
EASEMENT
zjl
f
f
p
T
15' SCREENING E
0
ti
~
�
Q
Z
z
u
O
Ln
�?
o
w
o
z
w
U
O
O
C
O
W
�
N
00'�
X0.77 '
v
�\s
<\s 000 00,
7,
0
3
SEMENT 15.00 ---�
— T
LIJQ
TRACT B1 RECR ATION CENTft o
o
SUBDIVISIO�� (85-82) w �^!
O
$ o TRACT B1 HAS 161,223 SQ.FT. OF AREA 0
1.5% OF THE TRACT IS C VERED
O
54.3 313.3 O
Exanxc xass
m—ao.s
182 l I
excn a V
3
0.6.6 0 oEz3
a�
15SCREENING EASEMENT
a EAS-MENT VACATED WITH DILAT
j^
MULDROW STREET
7A
TROY_DAVIS_HONIES
P.O. BOX 232293
Anchorage, Alaska 99523
(907) 227-5881
05-03-14 1 1"=50'
NW453,553 2140042
^awn by Field Boc
CEF 243
I hereby certify that the property described hereon has been surveyed
by me, or at my direction, and that the improvements situated thereon
e5 are within the property lines and do not overlap or encroach on the
property lying adjacent thereto unless otherwise shown. That no
improvements on the property lying adjacent thereto encroach on the
premises in question and that there are no roadways, transmission
lines or other easements on said property except as shown.
It is the responsibility of the owner or builder, prior to construction,
to verify proposed building grade relative to finish grade and utility
connections and to determine the existence of any easements, covenants,
or restrictions which do not appear on the recorded subdivision plat.
Listed distances prevail over scaling.
Reproduction may cause distortion.
15' T &
E E
TRACT JB1 _
RECREATION_ CENTER
SUBDIVISION
W&PLES E. FORBES : o %
o .
,'.. LS -7326