Loading...
HomeMy WebLinkAboutSKY MANOR LT 3 SKY MANOR5 ky Manor Lot 3 #051-193-42 Inspection Report _ -12. oe Municipality of Anchorage Community Development Department Page 1 of 3 On-Site water & Wastewater Program sl V N 92014 4700 Elmore St. - P.O. Box 196650 Anchorage, AK 99519-6650 - http://www.muni.org/onsite - (907)343-7904 ON-SITE WASTEWATER INSPECTION REPORT Permit Number: OSP141025 PID Number: 051-193-42 ® New E] Upgrade Nome: JOHN THOMSON ABSORPTION FIELD ❑ Deep Trench ❑ Shallow Trench ® Bed ❑ Mound Address: 11404 JESSIE MAE CIRCLE, EAGLE RIVER, AK 99577 ❑ Other Phone: No. of Bedrooms: Soil Rating' Total Depth from original grade: (907) 240-2020 *6 0.7 GPD/Sa. Ft. **9 Ft. LEGAL DESCRIPTION Depth to pipe invert from original grade: SEE DWG. Ft. Gravel depth beneath pipe: 0.53 Ft. Subdivision: SKY MANOR Block: Lot: — 3 Fill added above original grade: Gravel length: SEE DWG. Ft. 65 Ft. Township: Range: — — Section: _ Grovel width: Beds Number of lines. Distance between lines: 20 Ft. 4 5 Ft. SEPARATION DISTANCES Total absorption area: 1300 Number of trenahee: — Dist. between trenches: — To Septic Absorption Lift Holding Public/Private From Tank Field Station Tank Sewer Lines So. Ft. FL Well 200'+ 200'+ — — 25'+ TANK ®Septic ❑S.T.E.P. CHolding ❑Other Manufacturer: capacity: Surface water 100'+ 100'+ — — ANCHORAGE TANK 2000 Got. Lot Line 5'+ 10'+ - - N/A Material: STEEL Number of compartments: 2 Foundation 5'+ 10'+ — — LIFT STATION Curtain Droin NONE KNOWN Manufacturer: c IY: Gal. Remarks: *THIS IS A DUPLEX. "Pump an" level at: rap off" I High water alorm at: *2 FEET OF MOA SAND FILTER BELOW TOTAL DEPTH. Pump Make & Electrical Inspections performed by: PIPE MATERIAL House to tank D3034 Tank to D3034 drainfield Installer GREEN GENERAL CONTRACTING Drainfield D3034 CO/MT D3034 Inspector GEG, Ltd. BENCHMARK (Assumed elevation) 100.00 Ft. Inspection Location and Description: Dates: 1st 4/1/14 2nd 4/3/14 3rd 4/7/14 4th 4/14/14 DOOR THRESHOLD NEAR POINT "B" Community Development Department Approval ENGINEER'S SEAL _Qob000p (DF A.�gS�O Conditional approval: Date: ��QO T oQpai�P• ..... .................. �.� fey.......rness:... QO " CE 753 ,•' mph ��4�e '•.bT6�lrf'•'�0000 Approved: -/3 Date: DIP no, �40000�� Inspection Report _ -12. oe Lot 2 PROPOSED SEPTIC SYSTEM NEW 2000 GALLON SEPTIC TANK FCO 14'+ NEW GRAINFIELD �— WATER LINE LOCATION PER CONTRACTOR. FOURTEEN- FOOT SEPARATION TO GRAINFIELD PER CONTRACTOR. KEY BOXES rEXISTING WATER MAIN PARCEL ID NUMBER: X051-19342 f -••. Lot 4 PROPOSED SEPTIC SYSTEM CONFIRMATION TEST HOLE DUG PRIOR TO CONSTRUCTION. GARNESS ENGINEERING GROUP, Ltd CIVIL & ENVIRONMENTAL ENGINEERS 3701 E.TUWRR D, SMITE 101•ANGg E,MM0)'PI3W(SM M6179-IM(9pn 33632<9•WEB51E: wxn'gertaewglweM1gmn 'REPAIRED FOR: PHONE NUMBER: PAGE NUMBER• •,•••' JOHN THOMSON (907) 240-2020 2 OF 3 .EGAL DESCRIPTION: - DRAWN BY: SKY MANOR SUBDIVISION; LOT 3 J.L.M. •�4 YPE OF WORK: DATE: . AS -BUILT OF NEW SEPTIC SYSTEM 6/5/2014 6BEDROOM DUPLEX (UNDER CONSTRUCTION ALTERNATE A. �7 b PERMIT PARCEL ID OSPI41025: AS -BUILT DRAWING 051193-428ER. OSP141025 TOP OF TANK AT INLET = 95.38 INVERT OF BUNG AT INLET = 94.76 FILTER FABRIC INVERT OF DISTRIBUTION LINES= 94.39 - TOP OF SAND = 93.86 BOTTOM OF BED = 91.83 - 2' INSULATION � FINAL GRADE = 98.0-98.1 NEW 2000 GALLON SEPTIC TANK 20 FEET WIDE - TOP OF TANK AT OUTLET = 95.39 INVERT OF BUNG AT OUTLET = 94.59 GRADE = 98.30 - 100.90 ORIGINAL GRADE 101.33-102.83 MAX. DINT RELATIVE BOTTOM OF TEST HOLE N3 =87.33 (TEST HOLE DRY) RELATIVE BOTTOM OF TEST HOLE #313 = 85.83 ( TEST HOLE DRY) GARNESS ENGINEERING GROUP, Ltd�` CIVIL & ENVIRONMENTAL ENGINEERS 3XI E.TNWRRDAD.SUIIE 101'ANWO E,A MOI'PH NE (907 3374178'FM(90n 33BJ349'WEB81TE:xwn.genwee�gYxeilg.am PREPARED FOR: PHONE NUMBER: PAGE NUMBER: • '� JOHN THOMSON (907) 240-2020 3 OF 3 LEGAL DESCRIPTION: DRAWN BY: SKY MANOR SUBDIVISION; LOT 3 J.L.M. TYPE OF WORK: DATE: AS -BUILT OF NEW SEPTIC SYSTEM 6/5/2014 THN3 AND TWK1B GARNESS ENGINEERING GROUP, Ltd CIVIL & ENVIRONMENTAL ENGINEERS 3701E. TUDOR MAR SUITE 101'AN(DiORUDRAN99M7'PFOM(9R MY 179'FM(90T 33Sa'NB•W£BSrtE: xxw.yemms,pFwrFpcwn LEGAL DESCRIPTION: SKY MANOR SUBDIVISION; LOT 3 PERFORMED FOR: JOHN THOMSON DATE: 3/28/2014 DEPTH ---- (teeU ORGANICS ITEST HOLE #36 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 OA . DRY •• •l 0 M GW GP SW P �I //�i 417/14 ;YYY7`Y`IIGC y�y//pp�i 'YN�SC GP W/ SOME SILT AND COBBLE/ BOULDERS DEPTH TO GROUNDWATER DATE DRY 3/28/14 DRY 411/14 DRY 417/14 DATE READING CLOCK NET TIME WATER LEVEL NET DROP TIME (MINUTES) READING (INCHES) OHO. O O�PS�PS, ,NPS BSO¢SEO d1�I1k 19 PERCOLATION RATE <1 (MIN./INCH) PERC. HOLE DIA. 6 (INCHES) TEST RUN BETWEEN 11 FT. AND 12 FT. 20 A FOUR HOUR PRESOAK WAS PERFORMED: ❑ YES NO SOILS LOGGED BY: JODYMAUS PERCOLATION TEST PERFORMED BY: JODYMAUS rnMMFNITc• PERCOLATION READINGS ARE WITHIN 1/16 OF INCH. PERFORMED BY GEG, Ltd. I, JEFFREY A. GARNESS, CERTIFY THAT THIS WASP FO MED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE: L Is / On -Site Wastewater Disposal System Permit Permit Number: OSP141025 Tax Code Number: 05119342000 MUNICIPALITY OF ANCHORAGE Development Services Department On -Site Water & Wastewater Program 4700 Elmore Road, PO Box 196650 Anchorage, AK 99519-6650 Telephone: (907) 343-7904 Work Type: Septic Initial Permit Effective Dates: February 27, 2014 to February 27, 2015 Design Engineer: GARNESS ENGINEERING GROUP LTD Subdivision: SKY MANOR Site Legal Address: SKY MANOR LT 3 G:1159 Owner/Address: THOMSON JOHN E 11404 JESSIE MAE CIR EAGLE RIVER AK 995770000 Site Mailing Address: This permit is for the construction of: Y Disposal Field Y Septic Tank y -/-I/O` 3:30 Lot Size in Sq Ft: 40000 Total Bedrooms: 6 N Holding Tank N Privy N Private Well N Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80). 3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either: A. Open and Close on the same day. B. Covered, sealed, and heated to prevent freezing. Special Provisions: The entire subsurface disposal field and/or alternate is not within a 30 foot radius of a percolation test. The Engineer needs to do an additional percolation test prior to the construction of the septic field. Please submit stamped and signed results with the As -built Inspection Report. If the results require a design change, construction of the system will stop pending On -Site review and approval. AMC 15.65.060.6.3 III 3111 /14 GDi ep v+ses 4 ha clro�i.� �: end • Received By: Issued By: !/� Date: Z7 MUNICIPALITY OF ANCHORAGE Community Development Department . Phone: 907-343-7904 Development Services Fax: 907- 343-7997 On -Site Water & Wastewater Program Mayor Dan Sullivan r On -Site Sewer/Well Permit Application s RUSH!! For A Single Family Dwelling Parcel I.D. CSI— 1q�J—�a Property owner(s) JOHN THOMSON W/ CT CONSTRUCTION Day phone 240-2020 Mailing address 11404 JESSIE MAE CIRCLE * EAGLE RIVER, AK 99577 Site address NEEDELS LOOP * CHUGIAK, AK 99567 Legal description (Sub'd, Block & Lot) SKY MANOR; LOT 3 Legal description (Township, Section & Range) Lot Size Sq.Ft. Number of Bedrooms 6 APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DEWELLING: (®all that apply) Initial ® Single Family (SF) ❑ Absorption Field ® Upgrade ❑ (w/wo ADU) Septic Tank ® Renewal Duplex (D) ❑ Holding Tank ❑y `� ^y�� Multiple Dwellings El Privy El U B M I 1 ,'� Private WellA115H (SF and/or D) ❑ FEB 2 5 201 Water Storage F-1! J THIS APPLICATION INCLUDES A VARIANCE/ WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal codes. GARNESS ENGINEERING GROUP, Ltd. (Signature of property owner or authorized agent) Permit/RushFees: 56�1 ' 1, ORuS�) Waiver Fees: Date of Payment: Date of Payment: Receipt Number: dal U 0 G Receipt Number. Permit No. Osvlq loa-T_ Waiver No. (Rev. 09/12) GARNESS ENGINEERING GROUP, Ltd. CONSULTANTS & GENERAL CONTRACTORS mm February 21, 2014 Municipality of Anchorage Development Service Department On -Site Water & Wastewater Program 4700 Elmore Road P.O. Box 196650, Anchorage, Ak 99519-6650 (907) 343-7904 Ref: Proposed Septic System for Sky Manor Subdivision; Lot 3 To whom it may concern: The proposed 6 bedroom duplex is to be served by a community water system (under construction) and a private septic system. We are proposing to install a new 2000 gallon septic tank and a bed type drainfield. Two test holes were excavated on the property. An additional confirmation test hole is to be excavated prior to construction. The primary drainfield and alternate site will be designed around the 30 foot radii of TH#3 and this new test holes. Comments regarding the design are summarized as follows: 1. SOILS: See the attached logs which shows the soil classifications, groundwater monitoring, and the percolation test results. 2. DRAINFIELD DESIGN: See attached design drawing for drainfield specifications. 3. SURFACE WATERS: There are no surface waters within 100 feet of the proposed septic system. 4. TOPOGRAPHY: As can be seen on the attached site plan and design drawing, the topography is shown. In short, there are no slope concerns with this installation and there are no cutbanks such as road ditch with 50 feet that will impact the installation of the septic system. We are unaware of any adverse impacts this installation would have on adjacent wells or septic systems. If you have any questions, please contact us at 337-6179. Thank you for your assistance. ., .E., M.S. N071=: Attached is a site plan drawing, a design drawing, two soil logs, which are all part of the design package for this septic system. (Contact G.E.G. Ltd. for 7 page construction specification letter.) 3701 E. Tudor Road, Suite 101 * Anchorage, AK 99507-1259 Ph: (907) 337-6179 * Fax: (907) 338-3246 * Website: www.garnessengineering.com Lot 5 PO$E-0._..._ DUPE JP 6 BEDRgpM...... % ., OUPXEz .... ._.. /. '` PROPOSE �.... ...�-.L_ _..�•' 1 SEPT1O PR OSE "SYSTEM. ''� T SEPTIC __- " .... I •-- --' ..... H♦/3 __'_: _ ....I SYSTEM _........._ PROP ED' .. _- �. Lot 1 -sE Ic _ -. _ iNYP-!. 1- -- = • ::Hn .. - ] Lot f ! /- ALTERNATEStTE ALTERNATE SITE SUBDIVISION 1 tUNORF JEWEL LOr I ) ) j 1 I I E%15TH. I I CHURCx Q I / I �• 1 I GARNESS ENGINEERING GROUP, Ltd. CONSULTANTS 8 GENERAL CONTRACTORS 370t E. TUDOR ROAD, SUITE 101 • ANCHORAGE, Ax 99507 • PHONE (RO7)337-6179 • FM (907)3N-3246 •WEBSITE: •.� PHOmaFFFn innr' can PREPARED FOR: NE NUMBER: PAGE NUMBER: JOHN THOMSON 907-240-2020 1 OF 3 LEGAL DESCRIPTION: DRAWN BY: SKY MANOR SUBDIVISION; LOT 3 J.L.M. TYPE OF WORK: DATE: SITE PLAN FOR PROPOSED SEPTIC SYSTEM 2/21/2014 FOOT OF Ly. .._T._.._.._.._I._..�..T 510 y GIA\v\ ``�♦ `} `\ \ j tf T\ �`� i //�' ! L�7T 30 LOT 31 ! ! \\ j LOT 33 LOT 32 LOT 6 1 , LOT 28 j LOT 29 I ��� Cuss T'wEu I tt _-- , d f SERJES LOT 31 R 1\ UIQ Zia , c�EP ,C�� ! _-- / --- --�!•�/ L,?�� ! ' I i ! 50• C 1S4 \. i& i i Ley i Lot 5 PO$E-0._..._ DUPE JP 6 BEDRgpM...... % ., OUPXEz .... ._.. /. '` PROPOSE �.... ...�-.L_ _..�•' 1 SEPT1O PR OSE "SYSTEM. ''� T SEPTIC __- " .... I •-- --' ..... H♦/3 __'_: _ ....I SYSTEM _........._ PROP ED' .. _- �. Lot 1 -sE Ic _ -. _ iNYP-!. 1- -- = • ::Hn .. - ] Lot f ! /- ALTERNATEStTE ALTERNATE SITE SUBDIVISION 1 tUNORF JEWEL LOr I ) ) j 1 I I E%15TH. I I CHURCx Q I / I �• 1 I GARNESS ENGINEERING GROUP, Ltd. CONSULTANTS 8 GENERAL CONTRACTORS 370t E. TUDOR ROAD, SUITE 101 • ANCHORAGE, Ax 99507 • PHONE (RO7)337-6179 • FM (907)3N-3246 •WEBSITE: •.� PHOmaFFFn innr' can PREPARED FOR: NE NUMBER: PAGE NUMBER: JOHN THOMSON 907-240-2020 1 OF 3 LEGAL DESCRIPTION: DRAWN BY: SKY MANOR SUBDIVISION; LOT 3 J.L.M. TYPE OF WORK: DATE: SITE PLAN FOR PROPOSED SEPTIC SYSTEM 2/21/2014 FOOT OF GARNESS ENGINEERING GROUP, Ltd. CONSULTANTS S GENERAL CONTRACTORS+ 01 E 11OOR ROiY, aI11E 101 N•']*RVF, W. OW) a fNeft T9b9j$')- In • i - ' DATE SOIL LOG — PERCOLATION TEST LEGAL DESCRIPTION: TUNDRA JEWEL RANCH; LOT 20 — PROPOSED SKY MANOR, LOT 3 PERFORMED FOR: JOHN THOMSON DATE: 6/5/2007 DEPTH (feet) ____ 39�� ====_ ORGANICS TEST HOLE #31 :•s ___ SP/LOAM SOIL CLASSIFICATIONS 3 a:e GP ML l GM CL 4 ? GC OL % SW MH 5 t.; i•.: SP CH '=:h SM ' OH ¢ T .... ......... a f y ess,: ° CE77J5, i eG sc SEE ATTACHED DRAWINGS 6 10rl<<::,': , DEPTH TO GROUNDWATER DATE DRY 6/5/2007 DRY 6/12/2007 DRY 2/6/13 19� PERCOLATION RATE <1 (MIN./INCH) PERC. HOLE DIA. 6 (INCHES) TEST RUN BETWEEN 4 FT. AND 5 FT. 20 A FOUR HOUR PRESOAK WAS PERFORMED: ❑ YES NO SOILS LOGGED BY: JODY MAUS PERCOLATION TEST PERFORMED BY: BENNY MAUS PERFORMED BY GEG, Ltd.1, JEFFREY A. GARNESS, CERTIFY THAT THISWA P RFORMED IN ACCORDANCE G l WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE: 3 • • • aaa��a ��aaa�a 19� PERCOLATION RATE <1 (MIN./INCH) PERC. HOLE DIA. 6 (INCHES) TEST RUN BETWEEN 4 FT. AND 5 FT. 20 A FOUR HOUR PRESOAK WAS PERFORMED: ❑ YES NO SOILS LOGGED BY: JODY MAUS PERCOLATION TEST PERFORMED BY: BENNY MAUS PERFORMED BY GEG, Ltd.1, JEFFREY A. GARNESS, CERTIFY THAT THISWA P RFORMED IN ACCORDANCE G l WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE: 3 6 BEDROOM DUPLEX (UNDER CONSTRUCTIONr _P / TH#2 , y / y r / A _ Lot 3 ' _ PROPOSED - - - 6 BEDROOM DUPLEX Lot 2 LMSTEM ALTERNATE SITE I TO OBTAIN A COPY OF THE LETTER CONTACT CEG. BY PROCEEDING FORWARD WITH THIS INSTALLATION, THE -ENGINEER, WELL DRILLER, CONTRACTOR AND PROPERTY OWNER AGREE THAT THEY HAVE READ THESE SPECIFICATIONS AND AGREE TO ACCEPT THE TERMS AND N, \ i— ( - 1 r INSTALL L DOUBLE CLEANOUTS .� CO 15 T,4 ESMT / NUMBER OF BEDROOMS: 6 GALLONS PER DAY (GPD): 900 PERCOLATION RATE/S: <1 MIN/INCH PROPOSED APPLICATION RATE: 0.7 MINIMUM DRAINFIELD SO.FT.: 1286 'l DRAINFIELD DESIGN: / MAXIMUM DEPTH: 1/ FEET WIDTH: 20 FEET / LENGTH: 65 FEET M.D.A. APPROVED SAND FILTER: 2 FEET _ EFFECTIVE: 0.5 FEET REDUCTION FACTOR: N/A / ACTUAL SO.FT.: 1300 / / \ PROPOSED 6 BEDROOM -N,I,�- \ DUPLEX T TH#q (\ \ / PROPOSED �n 2000 GALLON LOt 4 / SEPTIC TANK MZ rO �GO T 113 OSED (FIELD J / / / / -_J -CONFIRMATION TEST HOLE. DUG PRIOR TO CONSTRUCTION. NOTE THE CONTRACTOR _ ALTERNATE SITE SHALL HAVE THE EAST AND WEST PROPERTY /-� - LINES FLAGGED PRIOR TO / WATER LINE /�CONSTRUCTION. y LOCATION PER CONTRACTOR _ EXISTING KEY /6SXES - --// / EXISTING WATER MAIN 17 20' SMTP y,-•17 GARNESSIENGINEERING GROUP, Lt � CONSULTANTS & GENERAL CONTRACTORS G 5701 E. IUWR B . SUM 101 • oMCH'JR . M 99N7 • PHUNS (8(_)399-6!n - EP% (907)3]8-SN6 • W SRE ­ymnexcrvpmsn,p.csn Yn PREPARED FOR:I F i UNE `IIIMBER: PAGE NUMB' JOHN THOMSON 907-240-2020 2 OF 3 LEGAL DESCRIPTION: DRAWN BY: SKY MANOR SUBDIVISION; LOT 3 J.L.M. _ TYPE OF WORK: - o DATE: REVISED DESIGN OF PROPOSED SEPTIC SYSTEM 1 3/31/2014 .... ... ....... i A. ..ar essr P" 1 ` o� e I v ROM SEPTIC TANK' r - O ,2.5•. 4" PERFORATED PIPE SOLID PIPE 2 O - _-----___ O 1 25. I FEET 5 FEET LONG FILTER FA INVERT OF DISTRIBUTION LINES (TYP.)— TOP OF SAND BOTTOM OF GRADE AT ORIGINAL GRADE 11' DEEP MAX. AT ANY POINT FEET WIDE — TEST HOLE DEPTH IS 15.5 FEET (NO WATER) GARNESS ENGINEERING GROUP, Ltd. CONSULTANTS & GENERAL CONTRACTORS 3701 E. TUDOR ROM. SUITE. 101 • ANCIIOWGE. M 99507 • PRDWE (907)337-61X • ME (907}136-3106 • WE6511E:....9amuangnevrinp.com PREPARED FOR: PHONE NUMBER: PAGE NUMBER: JOHN THOMSON 907-240-2020 3 OF 3 LEGAL DESCRIPTION: DRAWN BY: SKY MANOR SUBDIVISION; LOT 3 J.L.M. TYPE OF WORK: DATE: REVIS DESIGN OF PROPOSED SEPTIC SYSTEM 3/31/i 14 • 11 awn 1 .��� ey -+r-c orness: CE -195 d� GARNESS ENGINEERING GROUP, Ltd. CONSULTANTS & GENERAL CONTRACTORS +.�+ SOIL LOG - PERCOLATION TEST LEGAL DESCRIPTION: TUNDRA JEWEL RANCH; LOT 20 — PROPOSED SKY MANOR. LOT PERFORMED FOR: JOHN THOMSON DA TEST HOLE 4 SOIL CLASSIFICATIONS GW zz= ORG GP ML GM CL GC OL ° • S SW MH ' •� SP CH sM OH sc DEPTH TO GROUNDWATER DATE DRY 6/5/2007 DRY 6/12/2007 DRY 2/6/13 Fd IN 10 SEE ATTACHED DRAWINGS PERCOLATION RATE <1 (MIN./INCH) PERC. HOLE DIA. 6 (INCHES) TEST RUN BETWEEN 4.5 FT. AND 5.5 FT. -- A FOUR HOUR PRESOAK WAS PERFORMED: ❑ YES NO SOILS LOGGED BY: JODY MAUS PERCOLATION TEST PERFORMED BY: BENNY MAUS PERFORMED BY GEG, Ltd. I, JEFFREY A. GARNESS, CERTIFY THAT THIS WAS E FORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE: READI • � � aaa��a PERCOLATION RATE <1 (MIN./INCH) PERC. HOLE DIA. 6 (INCHES) TEST RUN BETWEEN 4.5 FT. AND 5.5 FT. -- A FOUR HOUR PRESOAK WAS PERFORMED: ❑ YES NO SOILS LOGGED BY: JODY MAUS PERCOLATION TEST PERFORMED BY: BENNY MAUS PERFORMED BY GEG, Ltd. I, JEFFREY A. GARNESS, CERTIFY THAT THIS WAS E FORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE: MUNICIPALITY OF t• Development Services Department �' r On -Site Water & Wastewater Section Parcel I.D. 051-193-42 Certificate of On -Site Systems Approval 1. GENERAL INFORMATION Phone: 907-343-7904 Fax: 907-343-7997 Expiration Date: - 7_0? 2 - Complete Complete legal description Sky Manor, Lot 3 Location (site address) 22692 Needels Loop Chugiak, AK Current property owner(s) Michele Bennett Day phone (907) 831-1605 Mailing address P.O. Box 671996, Chugiak, AK 99567 Real estate agent 2. TYPE OF DWELLING: ❑ Single Family (w/wo ADU) 0 Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) Day phone 3. NUMBER OF BEDROOMS: 6 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Private Well ❑ Private Septic 0 Water Storage ❑ Holding Tank ❑ Community Well 0 Community ❑ Public Water System ❑ Public Sewer ❑ Waiver request for: Distance: Received by: COSA to be released to the engineer, unless otherwise requested by the engineer. COSA Fee $ I'i I2, ►50 C'6 10-1 Date of Payment I 5J0 0� U Receipt Number. OWE 2 b cosA# O5G201 >ZA Date: Waiver Fee $ Date of Payment Receipt Number Waiver # 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is (are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. I acknowledge that On -Site staff may visit the site to verify the information submitted. Name of Firm Forge Engineering Phone (907) 522-7773 Address 1399 W. 34th Ave Suite 101, Anchorage, AK 99503 Engineer's Printed Name Michael E. Anderson, P.E. Date 7/14/2020 6. DSD SIGNATURE System #1 Approved for C� bedrooms System #2 Approved for bedrooms Disapproved Conditional approval for 9400 V4 PIP, OFESS bedrooms, with the following stipulations: -Iit(tttfW/" Original Certificate Date: 7 3-Z� The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: COSA Checklist X Nitrate Advisory Septic System Advisory Arsenic Advisory Well Flow Advisory Other COSA Checklist blue sheet COSA Checklist Legal Description: Sky Manor, Lot 3 Parcel ID: 051-193-42 If more than 1 septic system on lot: COSA Checklist # 1 of 1 Structure served by this system 1 A. WELL DATA ❑ Well log is filed with Onsite (or attached) Date drilled Total depth ft Cased to ft ❑ Sanitary seal is functioning correctly ❑ Wires are properly protected Casing height (above ground) in. Date of flow test for COSA Static water level at beginning of test ft. Comments COMMUNITY WELL PWSID #218807 B. TANK DATA Age of tank(s) 6 years Tank type/material SEPTIC/STEEL Measured operating fluid level in septic tank 50 ❑ Standpipes/foundation cleanout per record drawing Date of pumping 7/15/20 - JRs Septic Pumping Well production at time of test gpm Water storage tank volume gallons Well disinfected for coliform test? ❑ Yes ❑ Nc ❑ Coliform bacteria is Negative Nitrate mg/L ❑ Nitrate less than MRL (ND) Arsenic ug/L ❑ Arsenic less than MRL (ND) Collected by Date of Sample C. LIFT STATION ❑ Required maintenance completed Age of lift station years Lift station material Comments: N/A D. ABSORPTION FIELD DATA Absorption Bed Which system tested (date installed) 4/1/14 Adequacy test date 6/09/20 ❑ ALL standpipes present per record drawing *** Results ❑✓ Pass For 6 bedrooms Total measured depth from grade 8 ft.(max) Fluid depth prior to test 0 in Measured depth to pipe invert from grade 7.5 ft (min) Water added 918 gal ❑ N/A — pressurized field 0 New depth in ❑ Monitor tubes go to bottom of effective. If not, state 0 depth into effective Elapsed time min All Code -required soil cover over field Final fluid depth 0 in ❑ System presoaked Absorption rate '900 gpd (Required if vacant for greater than 30 days prior to Any rejuvenation treatment (past 12 months) None date of test) Gallons introduced gallons If yes, enter date Comments/Deficiencies: ***One of the four monitor tubes cannot be located. Swing ties were used to attempt locating the missing tube to no avail. The septic vents and post tank cleanouts are at grade and were located. COSA Checklist yellow sheet E. SEPARATION DISTANCES - Property served by a Community Water System From Private Well on Lot to: (Please enter distances if less than required or if community well) Septic Tank/Lift Station on Lot > 100' ❑✓ Yes Community Sewer Manhole/Cleanout > 100' ❑ Yes if No ft ❑ Yes if No ft Neighboring Tank > 100' ❑ Yes if No ft Private Sewer/Septic Line > 25' ❑ Yes if No ft Absorption Field on Lot > 100' ❑ Yes if No ft Holding Tank > 100' ❑ Yes if No ft Neighboring Absorption Fields > 100' ❑✓ Yes if No ft Water Main > 10' Animal Containment? 50' ❑ Yes if No ft ❑ Yes if No ft ® Yes if No ft Water Service Line > 10' ❑✓ Yes if No Manure/Animal Excreta Storage > 100' If septic tank is under driveway Community Sewer Main > 75' ❑ Yes if No ft 0 Yes if No ft From Septic/Holding Tank on Lot to: (Please enter distances if less than required) Building Foundations > 10'✓❑ ❑✓ Yes if No ft Surface Water > 100' ❑✓ Yes if No ft Property Line > 5' ✓❑ Yes if No ft Wells on Adjacent Lots: ❑✓ Absorption Field > 5' ❑ Yes if No ft Private Wells > 100' ❑✓ Yes if No ft Water Main > 10' 71 Yes if No ft Community Wells > 200' ® Yes if No ft Water Service Line > 10' ❑✓ Yes if No ft If septic tank is under driveway comment below From Absorption Field on Lot to: (Please enter distances if less than required) Building Foundation > 10' El Yes if No ft If absorption field is under driveway comment below Property Line > 10' ❑✓ Yes if No ft Wells on Adjacent Lots: Water Main > 10'✓❑ Yes if No ft Private Wells > 100' Water Service Line > 10' ❑✓ Yes if No ft Community Wells > 200' Surface Water > 100' 0 Yes if No ft F. ENGINEER'S COMMENTS Property is served by PWSID No. 218807. G. ENGINEER'S CERTIFICATION I certify that 1 have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this date. COSA Checklist yellow sheet F Yes if No ft ❑✓ Yes if No ft OF �S•• 9th es........... at MICHAEL E. ANDERSON c j 9 tv ,a No. CE -4381 7/16/20 ,••' • ti�'�4' `E0 --,11c Municipality of Anchorage 0,1 9 10 777 f On-Site Water and Wastewater Program (Nvre- in 343-7904 (N, SAFETY 'm JUL 27 2017 Certificate of On-Site Systems Ap oval cv tt J Parcel I.D. 051-193-42 Expiration :01 C";) 1. GENERAL INFORMATION: Complete legal description SKY MANOR; LOT 3 Location (site address) 22692 Needles Loop*Chugiak 99567 Current Property owner(s) Greg Endom Day phone 925-550-8082 Mailing address Real Estate Agent Day phone 2. TYPE OF DWELLING: ❑ Single Family (w/wo ADU) ® Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) 3. NUMBER OF BEDROOMS: 6 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well ❑ Individual Individual Water Storage ❑ Holding Tank ❑ Community Class A Well ® Community ❑ Public Water System ❑ Public Sewer ❑ WaiverNariance request for: Distance: • ` f j ,� � Received by. �/� Date: COSA to be released to the engineer,unless otherwise requested by the engineer. COSA Fee $ Waiver Fee $ Date of Payment 1 IP-77)11 Date of Payment Receipt Number 1]afr Receipt Number COSA#, 0C-rt Waiver# • 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm: Garness Engineering Group, Ltd (GEG) Phone: 907-337-6179 Address: 3701 East Tudor Road, Suite 101-Anchorage,Alaska 99507 Engineer's Printed Name: Jeffrey A. Garness Date: q , 1 / . .- �oQ,ao44 In conducting this evaluation, GEG provided an engineering evaluation of the well and/or septic system OF ,� t in accordance with the guidelines and regulations established by the Municipality of Anchorage and �.. .. industry practices. The reported results describe the condition of the system/s on the date/s of the �p4 1,,• *T.I.S4_1P0n evaluation. Separation distances were measured to readily identifiable features. Hidden defects or 9- _, 0fn)encroachments may exist that were not identified during the evaluation. The operational life of all wells * ••.Je v and septic systems depend upon a variety of variables, including but not limited to, soil conditions, f�' V� groundwater levels (that may fluctuate during the year), quality of construction (materials and 0 I D workmanship), and the water usage of the family utilizing the system's. These conditions can vary,and 'r .. . are outside the control of GEG. Satisfactory test results do not guarantee future performance of the Pd Jf ,S A, Gar ess. system/s; therefore, GEG makes no warranty(express or implied) regarding the future performance of V0' %. _T� . �, the well or septic system. GEG makes no representation whether an alternative well or septic system �nn s • 1: �c4 can be installed on the property in the event either of the current systems fail to perform adequately in u� �, ) •'1 c°o the future. The content of this report is for the sole benefit of the person/party that retained GEG to ��Q'Pro fess�o,O\ • perform the evaluation. Reliance upon the information provided in this report by any other person or ���pO�o� party (including subsequent property purchasers) is not authorized, nor will it confer any legal right whatsoever. #AECC884 6. DSD SIGNATURE System #1 Approved for (C: , bedrooms System #2 Approved for bedrooms J���,'i OF H;,V�h Disapproved ''' U ON-SITE Conditional approval for bedrooms, with the followinl•stil i ffpAND m l T; WASTEWATER C. `n PROGRAM r� 'Trr-------T—k— --- - Original Certificate Date: r.-- - 17 The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On-Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: COSA Checklist Nitrate Advisory Septic System Advisory _ Arsenic Advisory Well Flow Advisory Other COSA blue sheet 10-10-12.doc If more than 1 septic system is on the lot: COSA Checklist# of_ Structure served by this system Certificate of On-Site Systems Approval Checklist Legal Description: SKY MANOR; LOT 3 Parcel ID: 051-193-42 A. WELL DATA Well type COMMUNITY If A, B, or C provide PWSID#218807 Well Log (Y/N) Date completed Sanitary seal (Y/N) Wires properly protected (YIN Total depth ft. Cased to ft. Casing height(abo - around) in. FROM WELL LOG AT I CTION Date of test Static water level ft. ft. Well production g.p.m. g.p.m. WATER SAMPLE RES : Coliform colonies/100 ml. Nitrate mg./L. Collected by: enic: ug./L. Date of sample: B. SEPTIC/HOLDING TANK DATA Tank Type/Material SEPTIC/STEEL Date installed 4/1-14/14 Tank size 2000 gal. Number of Compartments 2 Cleanouts (Y/N) YES Foundation cleanout(Y/N) YES Depression over tank (Y/N) NO High water alarm (YIN) N/A Date of pumping 02 6,/'i Pumper Spm ciwst-y PuM Ls C. ABSORPTION FIELD DATA *BELOW EXISTING GRADE AT MT Date installed 4/1-14/14 Soil rating •.p.d./''or ft2/bdrm) 0.7 System type BED Length 65 ft. Width 20 ft. Gravel below pipe 0.53 ft. Total depth *5.2+ ft. Eff. absorption area 1300 ft2 Monitoring tube YES Depression over field NO Date of adequacy test 4/26/17 Results (Pass/Fail) PASS For 6 bedrooms Fluid depth in absorption field before test 0 in. Water added 926 gal. New depth 0 in. Elapsed Time: 0 min. Final fluid depth 0 in. Absorption rate >= 900+ g.p.d. Any rejuvenation treatment (past 12 mo.) (Y/N &type) NONE KNOWN If yes, give date - D. LIFT STATION Date installed Size in gallons Manhole/Access (Y/N) "Pump on" level at in. "Pump off' level at • wa er alarm level at in. - . Cycles tested Meets alarm&circuit requirements? E. SEPARATION DISTANCES SEPARATION DISTANCES FROM WELL ON LOT TO: COMMUNITY WELL Septic tank/lift station on lot On adjacent lots Absorption field on lot On adjacent lots Public sewer main '.• ' sewer manhole/cleanout Sewer/septic service line Holding tank - - containment areas Manure/animal excrete storage areas SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundation 5'+ Property line 5'+ Absorption field 5'+ Water main 10'+ Water service line '10'+ Surface water 100'+ Wells on adjacent lots 100'+PRIVATE&200'+COMMUNITY SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line 10'+ Building foundation 10'+ Water main 10'+ Water service line *10'+ Surface water 100'+ Driveway, parking/vehicle storage 10'+ Curtain drain NONE KNOWN Wells on adjacent lots100'+PRIVATE&200'+COMMUNITY F. COMMENTS 'PER CONTRACTOR THAT INSTALLED BOTH THE SEPTIC SYSTEM AND THE WATER SERVICE LINE-SEE ATTACHED STATEMENT. •'� OF i G. ENGINEER'S CERTIFICATION 4 :• 49� !certify that I have determined through field inspections and • :• • ••• review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this _. •• • �I • ?' date. ♦r^: �.r , A. - s r Engineer's Printed Name JEFFREY A. GARNESS •1>: E 7795 4 rtic Date 5Z-(a-971O LICENSE,t II�DFESS\ 4 4 #AECC884 w,i (Rev.10112/12) John and Jackie Thomson 907-695-5072 p.5 ���—. G"i6.7 b . . • i 6 �� : . 1 1 j ;l M 1 \ 1 J I I 6 C P } 1 �,\, ,,1 to k s I � r ! ' a , ` 1 1 � ' ,1 In ��c ' i.d i i 3 ' k I 8o a -'''. ! 8 e v . q L' i.1. .______ _______ L ,...,6,-,,.. .....4..e.....,7_ ,.,___er.„,:s,...i...2. _T SEWARD & ASSOCIATES LAND SURVEYING 694-0829 BY CERTIFY THAT I HAVE SURVEYED THESCALE: YING DESCRIBED PROPERTY: /�wo .����4t� . �4�mar 3 _--- -:- OF A L 1 4 tt kT NO ENCROACHMENTS EXIST t"XCEPT AS DATE; ..- •_. -q e ED- IT 1S THE RESPONSIBIi1 TY OF THE 9' /'S� -.-. _r s`f 3 f0 DETERMINE THE E(/STEN CE OF ANY GRID ..(1)..., 4° ��r �., NTS, COVENANTS, OR RESTRICTIONS ,."1".- --•'./. -5,1. o b NOT APPEAR ON THE RECORDED SUBD1- PLAT. UNDER NO CIRCUMSTANCES SHOULD FaVuari Nark Sewer _• $ 11 WPWAA1 QC fr .. ........-.•-..-_. eel% .. T' .16 �� �. �. �S-. � •�v� / i�' • Contractors Statement for Water Main and Water Service Lines October 6, 2014 To whom it may concern: 1, Dan Green, Owner of Green General Contracting, hereby certify that all water mains and water service lines for Sky Manor Water System that were installed by Green General Contracting, are ten (10) feet away from all septic tanks and drainfields. (-4 /0 Signature of Owner Date Dan Green, Owner Green General Contracting 15939 Division Street Chugiak, AK 99567 Phone: (907) 696-1805 Municipality of Anchorage On -Site Water & Wastewater Program (907) 343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL Parcel I.D. 051-193-42 Expiration Date: 1. GENERAL INFORMATION Complete legal description SKY MANOR SUBDIVISION; LOT 3 Location (site address) 22690,NEEDELS LOOP, CHUGIAK, AK 99567 Current Property owner(s) JOHN THOMSON W/ CT CONSTRUCTION Day phone 240-2020 Mailing address Real Estate Agent 11404 JESSIE MAE CIRCLE, EAGLE RIVER, AK 99577 2. TYPE OF DWELLING: ❑ Single Family (w/wo ADU) ® Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) 3. NUMBER OF BEDROOMS: 6 4. TYPE OF WATER SUPPLY: Day phone ,,SUPPMITTAI OCT u') �, 014;, TYPE OF WASTEWATER DISPOSAL: Individual Well ❑ Individual On-site Indiviriiial lNater Sfnraga_ ❑ Individual Holding tank ❑ Community Class "A" Well ® Community On-site ❑ Public Water System ❑ Public Sewer ❑ WaiverNariance request For: N/A Distance_ Received by: /— ® J Date: COSA to be released t the engineer, unless otherwise requested by the engineer, COSA Fee $ t �� 1 �, (• �o Waiver Fee $ Date of Payment lob /w Date of Payment Receipt Numberd[ `�J�°�"y Receipt Number COSA# o`yllI, `2 l Waiver# 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm GARNESS ENGINEERING GROUP, Ltd. Phone 337-6179 Address 3701 E. TUDOR ROAD, SUITE 101 * ANCHORAGE, AK 99507 Engineer's Printed Name JEFFREY A. GARNESS, P.E. Date t 112,/i V Engineer's Comments: In conducting this evaluation, GEG, LtD. attempted to provide a thorough, conscientious engineering analysis of the system in accordance with ADEC and MOA DSD Guidelines & Regulations. The reported results described the performance of the system under the conditions encountered at the time of the test, and separation distances measured to readily identifiable features. The operational life of all wells and septic systems depend on the local soils condition, groundwater levels that may fluctuate during the year, and the water usage of the family being served by the system. These conditions are outside the control of the evaluator of the system. Satisfactory test results do not guarantee future performance of the system, nor do they guarantee that there are no hidden defects or encroachments. GEG, LTD. can therefore not provide any warranty or future estimate of how long the system will continue to meet the operational requirements of the ADEC or MOA DSD. The content of this report is for the sole benefit of the owner listed above. Any reliance upon or use of this report by any other person or party is not authorized, nor will it confer any legal right whatsoever. 6. DSD SIGNATURE System #1 Approved for f ' bedrooms. System #2 Approved for Disapproved. Conditional approval for bedrooms. bedrooms, with the following stipulations: k� T6 7. 6, rness:' CE -7953 � iG-1! ( �./fit- ON-SITE =� WATER AND oSTEWATER oz^ GWP--,mAtA j 3 Original Certificate Date: / t% '._.?` /l> The Municipality orAde(orage Develop,emt Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the represenatations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTCHMENTS: COSA Checklist �� Nitrate Advisory Septic System Advisory Arsenic Advisory Well Flow Advisory Other (R< wns If more than 1 septic system is on the lot: COSA Checklist # _of_ Structure served by this system Certificate of On -Site Systems Approval Checklist Legal Description: _ A. WELL DATA Well type COMMUNITY Date completed Total depth - SKY MANOR SUBDIVISION; LOT 3 Parcel ID: 051-193-42 COMMUNITY WATER SYSTEM If A, B, or C provide PWSID# A Well Log (YIN) _ Sanitary seal (Y/N) Wires properly protected Cased to ft. CasZl� eight (abo n FROM WELL LOG AT CTION in. Date of test Static water level ft. ft. Well production g.p.m. g.p.m. WATER SAMPLE RESUL Coliform colonies/100 ml. Nitrate mg./L. Collected by: A c: ug./L. Date of sample: B. SEPTIC/HOLDING TANK DATA Tank Type/Material STEEL Date installed 4/1-14/2014 Tank size 2000 gal. Number of Compartments 6 Cleanouts (YIN) YES Foundation cleanout (YIN) YES Depression over tank (YIN) NO High water alarm (YIN) N/A Date of pumping NEW Pumper C. ABSORPTION FIELD DATA -BELOW EXISTING GRADE Date installed 411-14/2014 Soil rating 4H/ft r 0bdrm) 0_7 System type BED Length 65 ft. Width 20 ft. Gravel below pipe 0.5 ft. Total depth '4.4-7 ft. Eff. absorption area 1300 ft2 Monitoring tube YES Depression over field NO Date of adequacy test NEW Results (Pass/Fail) - For 6 bedrooms Fluid depth in absorption field before test = in. Water added =gal. New depth in. Elapsed Time: = min. Final fluid depth in. Absorption rate >= 900 g.p.d. Any rejuvenation treatment (past 12 mo.) (YIN & type) If yes, give date D. LIFT STATION Date installed Size in gallons Manhole/Access "Pump on" level at in. "Pump off" level Cycles E. SEPARATION DISTANCES SEPARATION DISTANCES FROM WELL ON LOT TO: Septic tank/lift station on lot Absorption field on Public sewer main Sewer /septic service level at in. Meets alar & circuit requirements? COMMUNITY WATER SYSTEM On adjacent On sewer manhole/cleanout Holding tank Manure/animal excrete storage areas SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundation 5'+ Property line 5'+ Absorption field 5'+ Water main 10'+ Water service line 10'+ Surface water 1001+ Wells on adjacent lots 100'+ PRNATE/209+ TO COMMUNITY WELL SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line 10'+ Building foundation 10'+ Water main 101+ Water service line 101+ Surface water 1001+ Driveway, parking/vehicle storage 10'+ Curtain drain NONE KNOWN Wells on adjacent lots 100'+ PRIVATE/200'+TO COMMUNITY WELL F. COMMENTS G. ENGINEER'S CERTIFICATION I certify that I have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this date. Engineer's Printed Name JEFFREY A. GARNESS Date JC> Lz h y (Rev. 10112J12) John and Jackie Thomson a N \1 ASSUiLT r� 907-696-5072 p.5 e e e o i o I c, .iA 1 HEREBY CERTIFY THAT I HAVE SURVEYED THE ISCALE: FOLLOWING DESCRIBED PROPERTY: AND THAT NO EhfCROACHMENTS EXIST EXCEPT AS INDICATED_ 1T DATE - 9��y IS THE RESPONSIBILITY OF THE OWNER TO DETERMINE THE EXISTENCE OF ANY GRID= EASEMENTS, COVENANTS, OR RESTRICTIONS WHICH DO NOT APPEAR ON THE RECORDED SUBDI— /vuijZs{ VISION PLAT. UNDER NO CIRCUMSTANCES SHOULD F3: ANY DATA HEREON RE USED FOR CONSTRUCTION OF FENCE LINES, OR FOR ESTABLISHING SOUND- - ARY LINES. DRAWN; OF At ya ^, � •. Dvena Mvk Sawa, �