HomeMy WebLinkAboutDENALY BLK 1 LT 15bencxly
Block 1
Lot 15
#067 - 041-21
Municipality of Anchorage Uhl: 4 2014
On-Site Water and Wastewater Program • (907) 343-7904 Page of
ON-SITE WASTEWATER INSPECTION REPORT
Permit Number OSP131391 PID Number: 067-041-21
Dwelling:
■
Single Family (SF) ❑ Duplex (D) ❑ Multiple (SF and/or D) Project:
•
New ❑ Upgrade
Na
T
Tro
Troy Davis Homes
ABSORPTION
❑ Deep Trench
FIELD
•
❑
other
Shallow Trench 0 Bed ❑ Mound
Address
165 E. Parks Hwy #200 Wasilla, AK 99654
Phone
357-9394
Number of Bedrooms
4
Soil Rating
.8 GPD/SF
Total depth from original grade
5.8 Ft.
LEGAL DESCRIPTION
Depth to pipe invert from original grade
Gravel depth beneath pipe
Subdivision Block Lot
Denaly 1 15
1.8 Ft.
4 Ft
Fill added above original grade
1-2 Ft.
Gravel length
58 Ft.
Township Range Section
Gravel width
5 Ft.
Beds: Number of Lines
Distance between lines
Ft
SEPARATION DISTANCES
To
From
Septic
Tank
Absorption
Field
Lift Station
Holding
Tank
Sewer
Line
Total absorption area -
580 Ft2
Number of trenches
2
Dist. between trenches
>10 Ft.
Well
>100'
>100'
>100'
NA
>25'
TANK ❑Septic NIS.T.E.P. • Holding El Other
Manufacturer
Anchorage Tank/Orenco
Capacity
1,250 Gal.
Surface Water
>100'
>100'
>100'
NA
Material
Steel
Number of compartments
Three
Lot Line
>5'
>10'
>5'
NANA
Foundation
>5'
>10'
>5'
NA
LIFT STATION
Manufacturer
Anchorage Tank/Orenco
Capacity
250 Gal.
Curtain Drain
None
Noted
Remarks
Pump on level at
42 in.
Pump off level at
38 in.
High water alarm at
44 in.
Pump make and model
OSH P2005-11
Electrical In pections performed by
Commercial Electric, Inc
Installer
Northern Excavation
PIPE MATERIAL House to tank D3034Tankto D3034
drainfield
Drainfield D3034 CO/MTD3034
Inspector A. Harala
BENCH MARK (Assumed elevation) 100.0 R
Inspdeii Sn 1n 3/27/14 2�d 3/27/14
Location and description
Garage Slab.
3" 3/28/14 4m
COMMUNITY DEVELOPMENT DEPARTMENT APPROVAL
Conditional Approval: Date
'':ntOF �'ly'''
e. eb
:As,. ..;s`A,,
lk; 49I • to
N HY •••• • ••c.
OH Inter see
#11 re MICHAEL E. ANDERSON • 4 Al
0r^• d'
. ff� fie .' L 4381Ng
, ... ��a —
? • t41a�'dD7;5'0�a et
.R.,.ay
Approved _/j tV Date la'S-l`i
Inspection Report_9-f-17do
Page 2 of 3
PID No.:067-041-21
Permit Number: OSP131391
/
Munpipality of Anchorage
DEVEOPMENT SERVICES DEPARTMENT
4700 Elmore Road Anchorage, AK. 99519-6655 - 343-7904
S1
S2
MH
M1
M2
A
22.1'
28.3'
29.5'
B
47.3'
45.5'
45.4'
10.6'
C
16.3'
27.5' 30,2'
Nt. Site
patTB
Nay
,esaagi
s,,(�, .9:...:4C.
49th - -
•
•
4
0
sr
MICHAEL E. ANDERSON
••• No. CE -4381
;D
-I -04****
•..„�•�
(3a
ALTERNATE SITE:
Advantex Treatment System with
15' Long x 5' Wide x 4'
Effective Depth Absorption
Trench. Application Rate 3
GPD/SF.
DENALY SUBDIVISION
LOT 15, BLOCK 1
PLAN AS BUILT
SCALE 1" = 50'
Permit Number OSP131391
Municipality of Anchorage
DEVEOPMENT SERVICES DEPARTMENT
4700 Elmore Road Anchorage, AK. 99519-6655 - 343-7904
On -Site Wastewater Disposal System or Well Inspection Report
Page 3 of 3
PID No. 067-041-21
Finished Grade
x
1-
98,0
f
99.8
2
/
Existing Grade
Geotextile Fabric
f
96.2-'
Drainfield Rock
92.2 --'
86.0 29' (Trench Length)
Groundwater @ 88'
10-9-13
Finished Grade
SOUTH TRENCH
x
r-
102.4
/ / 100.6
2
Existing Grade
Existing Grade
Geotextile Fabric
Existing Grade
f
98.9_\
Drainfield Rock
94.9—if
86.0
Groundwater @ 88'
10-9-13
29' (Trench Length)
NORTH TRENCH
PROFILE AS -BUILT
No Scale
F.
p 4_'
i 4`• 49th • ��J
afi
MICHAEL E ANDER 1sri�
�1 No. CE -4381 ' 1 4I
COMMERCIAL ELECTRIC, INCm
MMIERCIA( RESIDEN i,ALIINDUSTRfAL OFFICE, 907-841-1009
FAX: 907-631-4999
Troy Davis Homes,
12-2-14
The lift station @ 15-1 Denali Home in Eagle River Alaska was installed by Commercial Electric Inc. to
NEC code and 100% workmanship.
Thanks,
William Regallo
President/ Owner
907-841-1007
Admin. #1904
3
8
9
10
I I
12
13
14
15
16
17
18
MUNICIPALITY OF ANCHORAGE
DEVELOPMENT SERVICES DEPARTMENT/ON-SITE WATER AND WASTEWATER PROGRAM
4700 ELMORE ROAD, ANCHORAGE, AK 99519-6650
SOILS LOG - PERCOLATION TEST
PROJECT #:
PERFORMED FOR' Troy Davis Homes DATE PERFORMED: 9/25/2013
LEGAL DESCRIPTION'
4
OG/0L
4
o 4
Loh 15, Block 1, Denaly Subdivision
TEST HOLE # 1 SLOPE
Silty Gravel
aGW/GM
•
•
COMMENTS'
BOH
WAS GROUNDWATER
ENCOUNTERED?
Yes
IF YES, WHAT DEPTHS 10'
DEPTH OF WATER
AFTER MONITORING.
��• (E OF qC qyiii,
49th
_ D
yo MICHAEL E. ANDERSON j w
rn ; ., �
O Sr . ND. CE -4381 .•'
•/'..ROF SS0114•
.........
10'
DATE 10/9/13
S
L
0
P
E
SITE PLAN
See Site Plan
READING
DATE
GROSS
TIME
NET
TIME
DEPTH To
WATER
NET
DROP
1
9/25
1:32
3.75"
2
2=02
30
6.00"
2.25"
3
2:04
3.75"
4
2:34
30
6.00"
2.25"
5
2:35
3.75"
6
3:05
30
6.00"
2.25"
PERC RATE: 13 MIN./INCH PERC. HOLE DIAMETER: 6"
TEST RUN BETWEEN 4.0 FT AND 5.0 FT
Test Hole Pre Soaked Prior To Percolahion Test.
TEST PERFORMED BY: WADE I, MICHAEL E. ANDERSON CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE
WITH ALL STATE AND MUNICIPAL GUIDELINES ON THIS DATE: 10/16/13
Certified Drilling Log
BILI. & COLE
C
CO dba
ULLIVAN9WATER WELLS
�P.O. Box 670269,
, AK 99567 6811-2759
OWNER OF LAND: Troy Davis Homes
ADDRESS:
LEGAL DESCRIPTION
DATE: 4/1/14
Denaly Lot 15 Blk 1
PERMIT NUMBER: OSP131391 DATE OF ISSUE:
3/25/14
TAX IDENTIFICATION NUMBER 06704121000
Is well located at approved permit location: Yes UNo
Method of Drilling: Mair rotary ❑cable tool
Depth of Well: 211 ft
Casing Type: steel
Diameter: 6
Liner type none
Wall thickness 0.25 inches
inches, depth 207
feet
Static Water Level: Flowing feet
Recovery Rate 20 gpm U gph
Method of Testing air
Well Intake Opening Type: IA open end
❑ Screened Start
❑ Perforations Start
feet
feet Stopped
open hole
Stopped
Grout Type: bentonite Volume: 100 lbs
Depth: from 0 feet,
Well Disinfected Upon Completion:
o 20+ feet
yes U no
Method of Disinfection: Chlorine 50 ppm
Comments:
Bore Hole Data
Depth
From To
0
2
2
4
4
24
24
32
32
46
46
55
55
70
70
71
71
149
149
204
204
211
Casing Stickup
Overburden
Sand and Gravel
Silt, Sand, and Gravel with Clay
Hardpan
Clay, Silt, and Gravel
Hardpan
Silt and Water
Clay
Clay and Gravel
Gravel and Sand
Drillers Name: Cole Sullivan
ATTENTION: It is the responsibility of the property owner to submit a copy of the well log to the proper authority.
Municipality of Anchorage: Department of Health & Human Services and/or Department of Environmental Conservation.
MatSu Borough: Department of Environmental Conservation.
Municipality of Anchorage
Community Development Department
On -Site Water & Wastewater Program
4700 Elmore St. P.O. Box 196650 Anchorage, AK 99507-6650 www,muni.org/onsite
(907) 343-7904
Pump Installation Log
Well Drilling Permit Number: SW OSP131391
Date of issue 3/25/14
Parcel Identification Number: 06704121000
Legal Description
Denaly Lot 15 Mk 1
Property Owner Name & Address
Troy Davis Homes
Pump Installation Date: 6/11/14
Pump Intake Depth Below Top of Well Casing: 130 feet
Pump manufacturer's Name: Gould
Pump Model: 75B05412CL
Pump Size: 1/2 hp
Pitless Adapter Burial Depth: 10 feet
Pitless Adapter Installer: Northern Excavating
Disinfected Upon Completion?
yes ❑ no
Method of Disinfection: Chlorine 50 PPM
Comments: Pitless Adapter Manufacturer's Name: Harvard
Pump Installers Name: Cole & Chad Sullivan Water Wells
Attention: The pump installer shall provide a pump installation log to the 050 within 30 days of pump installation. Well
Disinfected Upon Completion?
On -Site Water & Wastewater System Permit
MUNICIPALITY OF ANCHORAGE
Development Services Department
On -Site Water & Wastewater Program
4700 Elmore Road, PO Box 196650
Anchorage, AK 99519-6650
Telephone: (907) 343-7904
Permit Number: OSP131391
Tax Code Number: 06704121000
Work Type: WellSeptic
Permit Effective Dates: March 25, 2014 to March 25, 2015
Design Engineer: ANDERSON ENGINEERING
Subdivision: DENALY
Site Legal Address: DENALY BLK 1 LT 15 G:0363
Owner/Address•
TROY DAVIS HOMES INC
165 E PARKS HWY #200 WASILLA AK 996547059
Site Mailing Address: 7000 KULCHAY CIR, Eagle River
4111 -fry
Lot Size in Sq Ft: 59924
Total Bedrooms: 3
This permit is for the construction of:
Y Disposal Field Y Septic Tank N Holding Tank N Privy Y Private Well N Water Storage
Yid
All construction must be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater
Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80).
3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services
Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either:
A. Open and Close on the same day.
B. Covered, sealed, and heated to prevent freezing.
L'oi lid di iOc& 101" v`e 'Led. 4/1/14
Received By: P( ®/ Date:
Issued By: ��1'j1 �� �� �I �jl�% Date: S
MUNICIPALITY OF ANCHORAGE
Community Development Department
Development Services Division
On -Site Water & Wastewater Program
Parcel I.D.
Property owner(s) Troy Davis Homes Day phone 310-2501
Mailing address 165 E. Parks Highway #200 Wasilla, AK 99654
Site address 7000 Kulchay Circle Eagle River, AK 99577
Phone: 907-343-7904
Fax: 907-343-7997
ON-SITE SEWER/WELL PERMIT APPLICATION
067-041-21
Legal description (Sub'd., Block & Lot) Denaly, Block 1, Lot 15
Legal description (Township, Range & Section)
Lot Size 59,924 Sq. Ft. Number of Bedrooms Three
APPLICATION IS FOR:
(® all that apply)
Absorption Field
Septic Tank
Holding Tank
Privy
Private Well
Water Storage
APPLICATION 1S AN:
Initial
Upgrade
Renewal
TYPE OF DWELLING:
Single Family (SF) 0
(w/wo ADU)
Duplex (D) 0
Multiple Dwellings ❑
(SF and/or D)
THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR:
Dis tance:
I certify that the above information is correct. I further certify that this is in accordance with
applicable Municipal Codes.
(Signature of property owner or authorized agent)
Permit/Rush Fees:
Date of Payment:
Receipt Number:
Permit No.
Permit App.: 'La.;
4330
1010 113
3
053434
OSP 13'.59/
Waiver Fees:
Date of Payment:
Receipt Number:
Waiver No.
ANDERSON ENGINEERING'
P.O.' BOX 240773
ANCHORAGE, AK 99524
677-7766 (FAX)
October 16, 2013
Municipality of Anchorage
Development Services Department
On -Site Water and Wastewater Program
4700 South Bragaw Street
Anchorage, AK 99519-6650
Subject: Lot 15, Block 1, Denaly Subdivision
Septic System Design and Permit Application
Impacts to Adjacent Properties
Dear Onsite Services Engineer
The owner of the subject lot intends to construct a new three-bedroom home on the lot.
We are therefore requesting a permit be issued for the construction of a new well and
septic system to accommodate the home. The attached Site Plan and backup
documentation identify the location and configuration of the proposed well and septic
system along with the altemate site. Also identified on the plans are the existing wells
and septic systems on surrounding lots. No conflicts exist between the proposed well
and septic system and wells or septic systems on adjacent lots. Drainage arrows are
shown on the site plan showing the grade and direction of flow on the lot. The drainage
pattern will not be changed as a result of this project.
The test hole placed on the lot in the area of the absorption trench and alternate site
indicate the presence of sandy silt sand with gravel. The percolation rate of the
material was determined to be 13 minutes per inch. Groundwater was found during
the placement of the test hole at 10' below the surface and remains at that location
today. An application rate of .8 gallons per day per square foot was used in the
design of the absorption system. We are proposing to place a new 1,250 -gallon STEP
tank and 2 new 28' long by 5' wide by 4' effective depth absorption trenches to treat
and dispose of the effluent generated in the house. The elevation of the distribution
line in the absorption trench will be 1' below the existing ground surface and the total
depth will be 5' below ground. A minimum of 3' of fill or 2" of insulation and 2' of fill will
be placed over the absorption trench and 4' over the septic tank.
The ground surface on the lot in the area of the septic system slopes to the south at a
grade approximating 15%. The new trench will be constructed parallel with the slope as
much as possible in conformance with Municipal requirements. The new septic system
will be constructed a minimum of 100' from all wells and any surface water and 10' the
proposed and existing water services in the area.
Lot 15, Block 1, Denaly Subdivision
October 16, 2013
Page Two
If the system is constructed in accordance with our design the following statements
apply:
1. The system, if constructed as designed, will have no adverse impact on the wells
in the area or those to be constructed in the future.
2. The system, if constructed as designed, will have no adverse impact on existing
septic systems in the area or those to be constructed in the future.
3. The system, if constructed as designed, will have no adverse impact on reserve
space, either surface or subsurface, on any lots located in the area.
4. The system, if constructed as designed, will have no adverse impact on drainage
patterns in the area. The current drainage pattern will be maintained.
Sincerely, a/ -1 --,
Michael E. Anderson, P.E.
Attachments
COI
1
IULORAY
CIR.
2-ge' Long x 5' wide
x 4 Effective Depth
Absorption Trenches
eV:
11
7/
11
f,
I
e
Existing
Well
14
Septic Area
�Cs9
•TRA/CT B
/ALTERNATE SITE:
• Advantex Treatment Systen' with
15' Long x 5' Wide x $�
Effective Depth Absorption
Trench. Applicatiga Rote 3
GPD/SF. / 1
e:
0)$,
`+s
.4
NOTE:
No Conflicts with Wells or
Septic Systems on Adjacent
Lots. No Slopes >25% are
Within 50' of the Proposed
Absorption Site.
DENALY SUBDIVISION
LOT 15, BLOCK 1
SITE PLAN
SCALE 1" = 50'
LOT 15, BLOCK 1, DENALY SUBDIVISION
DESIGN FACTORS:
Three Bedroom System
Perc. Rate: 13 Min./Inch
Application Rate: .8 GPD/SF
SYSTEM REQUIREMENTS:
5' Wide Trench System
1,250 Gallon STEP Tank
4' Drainfield Rock
Pressure Distribution System
3 Bedrooms X 150 GPD/.8 GPD/SF (Application Rate) = 562.5 SF Absorption Area
562.5 SF/5 SF/ LF* .5 (Red. Factor) = 56.2 LF Trench Length
THEREFORE: Construct 2 New 28' Long x 5' Wide x 4' Effective Depth Absorption Trenches.
Flow Line Elevation in Trenches to be at 1' Below Original Ground Surface. Total Depth to be
5.0' Below Existing Ground. Provide 4' Cover Over STEP Tank and 3' Cover Over
Absorption Trench.
Place 6" Topsoil and
Revegetate Mound
4'0"
1.25" Perforated
PVC (Holes Down)
15 - 3/16" Diameter Holes
Per Lateral @ 1.9' Spacing
Drainfield Rock
5'
Existin. Ground
TYPICAL 5' WIDE TRENCH SECTION
�.�P�E.. ..: OF q< •ip.
� 49thyt° * 3
ter. •'�l°
the Area. I A MICHAEL E. ANDERSON W •
Water or Streams. O.`'?- Na CE -0381 :411
NOTE:
(NO SCALE)
Grade Area Over Trench to Drain Away.
Minimum 6' Separation From Bedrock.
Minimum 4' Separation From Groundwa
Minimum 100' Separation From Wells in
Minimum 100' Separation From Surface
MUNICIPALITY OF ANCHORAGE
DEVELOPMENT SERVICES DEPARTMENT/ON-SITE WATER AND WASTEWATER PROGRAM
4700 ELMORE ROAD, ANCHORAGE, AK 99519-6650
SOILS LOG - PERCOLATION TEST
PROJECT #:
PERFORMED FOR: Troy Davis Homes DATE PERFORMED' 9/25/2013
LEGAL DESCRIPTION'
2-
3
4-
7-
8-
9-
10-
II -
12
13
14
15
16
17
18
n
4 4
n
4 .
COMMENTS'
0G/OL
Lot 15, Block 1, Denalv Subdivision
TEST HOLE # 1 SLOPE
Silty Gravel
GW/GM
BOH
WAS GROUNDWATER
ENCOUNTERED?
Yes
IF YES, WHAT DEPTH? 10
DEPTH OF WATER
AFTER MONITORING:
.amil24q
ts‘
49th
0 p, ? oEasoN ^w
•W
#r'rJ :, No. EE -1381 �C2I
10'
DATE' 10/9/13
S
L
0
P
E
SITE PLAN
See Site Plan
READING
DATE
GROSS
TIME
NET
TIME
DEPTH To
WATER
NET
DROP
1
9/25
1:32
375"
2
2:02
30
6.00"
2.25"
3
2:04
3.75"
4
2:34
30
6.00"
2.25"
5
2:35
3.75"
6
3:05
30
6.00"
2.25-
PERC RATE: 13 MIN./INCH PERC. HOLE DIAMETER' 6"
TEST RUN BETWEEN 4.0 FT. AND 5.0 FT
Test Hole Pre Soaked Prior To Percolation Test.
TEST PERFORMED BY: WADE _ I, MICHAEL E. ANDERSON CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE
WITH ALL STATE AND MUNICIPAL GUIDELINES ON THIS DATE: 10/16/13
MUNICIPALITY OF ANCHORAGE
tDevelopment Services Department Phone: 907-343-7904
On -Site Water & Wastewater Section Fax: 907-343-7997
Parcel I.D. 067-041-21
Certificate of On -Site Systems Approval
Expiration Date: 8-19-22
Legal description Denaly Block 1 Lot 15
Site address 7000 Kulchay Circle Eagle River Ak 99577
Current property owner(s) John Krajzynski
X The On-site system(s) is/are approved for 4 bedrooms
Conditional approval for bedrooms, with the following stipulations:
Comments or advisories:
Original Certificate Date:
This Certificate of On -Site Systems Approval (COSA) is intended to demonstrate the subject
system(s) is/are in substantial compliance with municipal code. The Municipality of
Anchorage, Development Services Department (DSD) issues COSAs based upon
representations provided by an independent professional engineer. The Municipality of
Anchorage is not responsible for errors or omissions in the professional engineer's work.
ATTACHMENTS:
COSA Checklist X Well Flow Advisory
Absorption Field Advisory Nitrate Advisory
Tank Age Advisory Arsenic Advisory
Other
COSA ApprovMjune 2022
MUNICIPALITY OF ANCHORAGE
Development Services Department y Phone: 907-343-7904
On -Site Water & Wastewater Section Fax: 907-343-7997
Certificate of On -Site Systems Approval Application
1. GENERAL INFORMATION
Parcel I.D. 067-041-21
Complete legal description DENALY BLOCK 1 LOT 15
Location (site address) 7000 KULCHAY CIRCLE EAGLE RIVER, AK 99577
Current property owner(s) JOHN & KATHERINE KRAJZYNSKI Day phone
2. ON-SITE SYSTEMS SIZED FOR 4 BEDROOMS
3. TYPE OF WATER SUPPLY: ® Private Well ❑ Private Well serving 2 dwelling units
❑ Private Well serving 3+ dwelling units ❑ Community Well or Public
❑ Water Storage
4. TYPE OF WASTEWATER DISPOSAL: ® Private Septic ❑ Private Septic serving 2 dwelling units
❑ Holding Tank ❑ Community Septic or Public Sewer
5. SEPTIC TANK: ® Steel ❑ Plastic ❑ Concrete ❑ Fiberglass
Age 8 - See advisory if steel older than 20 years
6. ABSORPTION FIELD: ❑ AWWTS ❑ Bed ❑ Deep Trench ® Wide Trench ❑ Seepage Pit
Waiver request for:
Expedited review requested: ❑
Distance:
By applying for this entitlement, this property is subject to inspection by municipal On-site staff
to verify the accuracy of the information provided.
COSA Fee $ 5 5 Waiver Fee $
Date of Payment T o� Date of Payment
COSA # SCS 1 3 I Waiver #
COSA Application—July 2022 copy.doc
COSA Checklist
Legal Description: DENALY BLOCK 1 LOT 15 Parcel ID: 067-041-21
If more than 1 well and/or septic system on lot, provide separate checklist. Structure served by this system
A. WELL DATA
® Well log is filed with Onsite (or attached)
Date drilled 4/1/14 Total depth 211 ft
Cased to 207 ft
® Sanitary seal is functioning correctly
® Wires are properly protected
Casing height (above ground) 24+ in.
Date of flow test for COSA 8/3/22
Static water level at beginning of test 0 ft.
Comments: APPARENT ARTESIAN WELL.
Well production at time of test 4.5 gpm
Water storage tank volume NA gallons
Well disinfected for coliform test? ❑ Yes ® No
® Coliform bacteria is Negative
Nitrate _mg/L ® Nitrate less than MRL (ND)
Arsenic ug/L ® Arsenic less than MRL (ND)
Collected by FWN z
Date 8/3/22
B. TANK DATA C. LIFT STATION
Measured operating fluid level in septic tank 50" ® Required maintenance completed
Date of pumping 8/3/22 Age of lift station 8 years
❑ Required maintenance completed, if AWWTS Lift station material STEEL
Comments: Comments:
D. ABSORPTION FIELD DATA
Which system tested (date installed) 3/27/14
® ALL standpipes present per record drawing
Total measured depth from grade 6_9 ft (max)
Measured depth to pipe invert from grade _ft (min)
® N/A — pressurized field.
❑ Per record drawings, field is insulated.
® Monitor tubes go to bottom of effective.
If not, state depth into effective
❑ Presoaked required if
(Required if house vacant or field not used for more
than 30 days prior to date of test)
Gallons introduced gallons date
Any rejuvenation treatment (past 12 months) N
If yes, enter date
Adequacy test date 8/3/22
Results E Pass
Fluid depth prior to test 0 DRY in
Water added 600 gal
New fluid depth 7 in
Elapsed time <1440 min
Final fluid depth 0 DRY in
Absorption rate 600 gpd
FIELD STATUS — POST RECOVERY
Effective depth (per record drawings) 48 in
Effective depth used 48 in
Effective depth remaining 0 DRY in
Comments/Deficiencies: MT WAS FOUND BY DIGGING NEAR DRIVEWAY & WAS DRY. TESTED LOWER
TRENCH.
COSA Checklist—July 2022 copy.docx
E. SEPARATION DISTANCES
From Private Well on Lot to: (Please enter distances if less than required or if community well on lot)
Septic Tank/Lift Station on Lot > 100'
Community Sewer Manhole/Cleanout > 100'
® Yes
if No
ft
® Yes
if No ft
Neighboring Tank > 100' ® Yes
if No
ft
Private Sewer/Septic Line > 25' ® Yes
if No ft
Absorption Field on Lot > 100' ® Yes
if No
ft
Holding Tank > 100' ® Yes
if No ft
Neighboring Absorption Fields > 100'
Animal Containment > 50' ® Yes
if No ft
® Yes
if No
ft
Manure/Animal Excreta Storage > 100'
Community Sewer Main > 75' ®Yes
if No
ft
® Yes
if No ft
❑ N/A — Served by Community Well (not on lot) or Public Water
From Septic/Holding Tank and Absorption Field(s) on Lot to: (Please enter distances if less than required)
Building Foundations > 10' ® Yes if No ft Surface Water > 100' ® Yes if No ft
Tank to Property Line > 5' ® Yes if No ft Wells on Adjacent Lots:
Field to Property Line > 10' ® Yes if No ft Private Wells > 100' ® Yes if No ft
Water Main > 10' ® Yes if No ft Community Wells > 200' ® Yes if No ft
Water Service Line > 10' ® Yes if No ft If tank or field is under driveway comment below
F. ENGINEER'S COMMENTS
G. CERTIFICATION & STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based
on procedures outlined in the Certificate of On -Site Systems Approval Guidelines, indicates that the on-site water
supply and/or wastewater disposal system appears to comply with applicable Municipal and State codes,
ordinances, and regulations in effect at the time of installation, unless noted otherwise.
Name of Firm FIRST WATER CONSULTING Phone 907-350-9566
Engineer's Printed Name CURTIS HUFFMAN, PE Date 8110/22
Comments: This investigation was completed in compliance with MOA guidelines, regulations, "\
and best industry practices / methods. The assessment of the condition of the well and septic �� k``
applies only to the conditions as of the day tested. The flow and absorption rates may change � A �``,
due to subsurface conditions that may not be observed from the surface, changes in land use, A A�i, • • ' • • • : ry� 11
local soil characteristics, groundwater levels that may fluctuate during the year, quality of `'•' ;,`
construction (workmanship & materials), the water usage of the family being served by the �g�•• •.'9 ��j
system and maintenance. The operational life of all well and septic systems are subject to *� TM • * (�
these various and dynamic characteristics and are outside the control of the evaluator of the , • .. .... ......... .
well and septic system. Therefore, any estimate of how long a system will function satisfactory
for current or future occupants or guarantee that no unseen encroachments, deficiencies or F .... ... .
discrepancies exist can be given by First Water Consulting & fWGS
4 '• Curtis Huffman
�'c�`G, •. CE 128991
Ldp • 8/10/22 v�
FqF�••...••'\:C.*�
COSA Checklist—July 2022 copy.docx
MUNICIPALITY OF ANCHORAGE
Development Services Department Phone: 907-343-7904
On -Site Water & Wastewater Section Fax: 907-343-7997
Lift Station/Pump Vault
Maintenance Log
Owner Street Address 7L6?) ,LK
Septic Tank: Ili
-Sludge level B, inches -Pumping: required ygs-Q -Pumping completed ( �Rno
Lift station: zso�y
-Pump basket cleaned es no -Effluent filter cleaned Ce
)s no
.Control floats cleaned ,e no.- -Proper float settings confirmed (S)no-
-Operation satisfactory Fen o
Alarm System:
-Dedicated electrical alarm circuit (yej no -Audible and visual alarm inside dwelling /Ves no
-Alarm system operation satisfacto , not satisfactory
Manhole Riser
-Ground water intrusion at riser to tank connection yes no
-Ground water intrusion around pipe penetrations es o -Weep hole functional es no
-Manhole lid: Functional Insulated Properly Secured
es
Other
-All manufacturer required inspections and maintenance completed"lye-k, no
Comments:
Qualified Maintenance Provider:
Technician Loscq 1z,
Company
Signature
Date of maintenancekq+ll
Date L3U%__A1
Parcel I.D. 067-041-21
Municipality of Anchorage
On -Site Water and Wastewater Program
(907) 343-7904
Certificate of On -Site Systems Approval
1. GENERAL INFORMATION
Complete legal description Denaly, Block 1, Lot 15
Expiration Date: 3- S / S
Location (site address) 7000 Kulchay Circle Eagle River, AK 99577
Current Property owner(s) Troy Davis Homes, Inc. Day phone 357-9394
Mailing address
165 E. Parks Highway, No. 200 Wasilla, AK 99654
Real Estate Agent Day phone
2. - TYPE OF DWELLING:
❑ Single Family (w/wo ADU)
❑ Duplex \VI
\-----S-1
9 Multiple Dwellings (Single Family and/or Duplex)
3. NUMBER OF BEDROOMS:
Three
4. TYPE OF WATER SUPPLY:
Individual Well
Individual Water Storage ❑
Community Class Well ❑
Public water System ❑
TYPE OF WASTEWATER DISPOSAL:
Individual
Holding Tank
Community
Public Sewer
0
WaiverNariance request for: Distance:
Received by:
COSA to be releaser' e engineer, unless otherwise requested by the engineer.
Date: IQ.5
COSAFee $ cg.%t
tiIPo -7- t"l�6 Waiver Fee $
Date of Payment I2!/t / j )y (J> Date of Payment
Receipt Number t52to?�a1�1 dd Receipt Number
COSA # O i I 141- I Waiver #
5. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation,
based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application,
shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate
for the number of bedrooms and type of structure indicated herein. 1 further verify that based on the information
obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water
supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes,
ordinances, and regulations in effect at the time of installation.
Name of Firm Anderson Engineering Phone 522-7773
Address P.O. Box 240773 Anchorage, AK 99524
Engineer's Printed Name Michael E. Anderson, P.E.
6. DSD SIGNATURE
System #1 Approved for 3 bedrooms
System #2 Approved for bedrooms
Disapproved
Conditional approval for
By:
:gate 12/1/14
f. -,r tri\\\
O� OF A(\I11
�� ''••••...;45111
P•''
*al `�49� I.
t.`r r�c`•f:4.7
I A„ .II a *a E ANDBtSON .:,..t, ::
1044.7A CE -4381 .'�a�
+ ilik, 0 ES I ��=
bedrooms, with the following stipulations:
`PJ�Y tOF '`1Nf.
S.,�-
�Z WATFR AND `�
v WASTEWATER
1
3% �C) .'
JPAITSFION
Original Certificate Date: (.2 — ST' / 'L
The 114 nchorage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only
upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality
of Anchorage is not responsible for errors or omissions in the professional engineer's work.
7. ATTACHMENTS:
COSA Checklist X
Septic System Advisory
Well Flow Advisory
COSA blue sheet f "- 33
Nitrate Advisory
Arsenic Advisory
Other
If more than 1 septic system Is on the lot:
COSA Checklist # of _
Structure served by this system
Certificate of On -Site Systems Approval Checklist
Legal Description: Denaly, Block 1, Lot 15 Parcel ID: 067-041-21
A. WELL DATA
Well type Private If A, B, or C provide PWSID # Well Log (Y/N) Y
Date completed 4/1/14Sanitary seal (Y/N) Y Wires properly protected (YIN) Y
Total depth
211 ft. Cased to 207 ft. Casing height (above ground) >18 18 in.
FROM WELL LOG AT INSPECTION
Date of test 4/1/14
Static water level 0 ft. ft.
Well production 20 g.p.m. g.p.m.
WATER SAMPLE RESULTS:
Coliform 0 colonies/100 mL Nitrate 4.00 mg/L
Arsenic ND ug/L Date of sample: 10/7/14 Collected by: Anderson Engrg.
B. SEPTIC/HOLDING TANK DATA
Tank Type/Material STEP/Steel Date installed 3/27/14
Tank size 1,250 gal. Number of Compartments 3 Cleanouts (YIN) Y
Foundation cleanout (Y/N) Y Depression over tank (Y/N) N High water alarm (Y/N) Y
Date of pumping New Const. Pumper
C. ABSORPTION FIELD DATA
Date installed 3/27/14 Soil rating (g.p.d./ft2 or ft2/bdrm) .8 GPD/SF System type 5' Wide
Length 2 @ 29 ft. Width 5 ft. Gravel below pipe 4 ft.
Total depth 8.5 ft. Eff. absorption area 580 ft2 Monitoring tube Y Depression over field N
Date of adequacy test New Const. Results (Pass/Fail) For bedrooms
Fluid depth in absorption field before test in. Water added gal. New depth in.
Elapsed Time: min. Final fluid depth in. Absorption rate >= g.p.d.
N
Any rejuvenation treatment (past 12 mo.) (YIN & type) If yes, give date
D. LIFT STATION No Add On Manhole - Gravity Flow to Absorption Trench.
Date installed 3127/14
"Pump on" level at 42 in.
Datum Bottom of Tank
E. SEPARATION DISTANCES
WELL ON LOT TO:
Septic tank/lift station on lot
Absorption field on lot
Public sewer main
Sewer /septic service line
Animal containment areas
Size in gallons 250
"Pump off' level at
38
in.
Manhole/Access (Y/N)
High water alarm level at
Y
44
in.
Cycles tested New Const. Meets alarm & circuit requirements?
>100' >100'
>100' >100'
N/A N/A
>25'
>50'Manure/animal excrete storage areas >100'
On adjacent lots
On adjacent lots
Public sewer manhole/cleanout
N/A
Holding tank
Y
SEPTIC/HOLDING TANK ON LOT TO:
Building foundation >5' Property line >5'
Water main >10' ' Water service line >10'
Wells on adjacent lots >100'
ABSORPTION FIELD ON LOT TO:
Property line 4' Building foundation >10'
.10
Water Service line >10Surface water >
Curtain drain None Noted
F. COMMENTS
Wells on adjacent lots >100'
Absorption field >5'
Surface water >100'
Water main N/A
Driveway, parking/vehicle storage >10'
G. ENGINEER'S CERTIFICATION
I certify that I have determined through field inspections and
review of Municipal records that the above systems are in
conformance with MOA COSA guidelines in effect on this date.
Engineer's Printed Name Michael E. Anderson, P.E.
Date 12/1/14
COSA brown sheet 10-10-12.doo
..ail,OF•gL tt
i*' 49 •*e
d "I : NOVA E. ANDERSON: W N
'. CEE-4381 •'2`"s
♦ttttlt (5 -4r
LOT 15 BLOCK 1 HAS 59,924 SQ.FT. OF AREA
KULCHAY
CIR.
/
/
/
16
14
S_
9
<4
(,)op TRACT B
fG0
7
8,
9
GRAPHIC SCALE: 1 /nch = 40 Feet
80
Recert 11-13-14
FOR: Troy Davis Homes
FORBES & ASSOCIATES, INC
P.O. BOX 232293
Anchorage, Alaska 99523
(907) 227-5881
Date
8-27-14
Scale
1" = 40'
Grid
SW 363
As -Built Survey
2130194
Lot
Drawn by
CEF
Field Book
244
I hereby certify that the property described hereon has been surveyed
by me, or at my direction, and that the improvements situated thereon
are within the property lines and do not overlap or encroach on the
property lying adjacent thereto unless otherwise shown. That no
improvements on the property lying adjacenttheretoencroach on the
premises in question and that there are no roadways, transmission
lines or other easements on said property except as shown.
It is the responsibility of the owner or builder, prior to construction,
to verify proposed building grade relative to finish grade and utility
connections and to determine the existence of any easements, covenants,
or restrictions which do not appear on the recorded subdivision plat.
Listed distances prevail over scaling.
Reproduction may cause distortion.
M
Legal Description
15 Block 1
DENALY
SUBDIVISION
•N OF 441
_
(.2,„• . r v pIO
S* 4918 /\. t
x/.....4.....1'' * !.
CHARLES•
FORBES :6' r
E.
t* 7r�•. LS -7326 ��
I•
:
I�e�. 11-26-14 • ,Dt_
i