Loading...
HomeMy WebLinkAboutPANORAMA TERRACE BLK 2 LT 4Panorama Terrace Block 2 Lot 4 #015-092-64 Municipality of Anchorage On -Site Water and Wastewater Program • (907) 343-7904 OCI togage - 1 of9 ON-SITE WASTEWATER INSPECTION REPORT Permit Number: OSP141080 PID Number: 015-092-64 Dwelling: 0 Single Family (SF) ❑ Duplex (D) ❑ Multiple (SF and/or D) Project: N New ❑ Upgrade Name: JONATHAN SCHICK ABSORPTION FIELD H Deep Trench ❑ Shallow Trench ❑ Bed ❑ Mound Address 9200 PANORAMA DR ANCHORAGE AK ❑ Other Phone Number of Bedrooms Soil Rating Total depth from original grade 4 0.8 GPD/SF 7.1 Ft. LEGAL DESCRIPTION IDepth to pipe invert from original grade 1.5 pt Gravel depth beneath pipe 5.5 Ft Subdivision Block Lot PANORAMA TERRACE 2 4 Fill added above original grade 1.5-2.5 Ft. Gravel length 2X40 = 80 Ft. Township Range Section Gravel width 3.0 Ft. Beds: Number of Lines Distance between lines Ft. SEPARATION DISTANCES To Septic Absorption Lift Station Holding Sewer Total absorption area Number of trenches Dist. between trenches From Tank Field Tank Line 880 Fe 2 11 Ft. Well >100' >100' NA NA >25, TANK ■ Septic ❑ S.T.E.P. ❑ Holding ❑ Other Manufacturer GREER Capacity 1250 Gal. Surface Water >10()' >100' NA NA Material Number of compartments Lot Line >5' >10' NA NA STEEL 2 NA Foundation >5' >10' NA NA LIFT STATION Manufacturer Capacity Curtain Drain >50' >50' NA NA Gal. Remarks Pump on level at in. Pump off level at -- in. High water alarm at -- in. Pump make and model Electrical Inspections performed by Installer AA,, 6dacter AaSonc!N PIPE MATERIAL Housetotank 3034 Tankto drainfield 3034 Drainfield3034 CO/MT F810 Inspector LARS SPURKLAND/ANSON MOXNESS BENCH MARK (Assumed elevation) 100 ft Inspeection 1s' 8/13/14 8/13/14 Location and description ction 2nd 3'" 8/14/14 41" 8/14/14 TOP FOUNDATION SW CORNER COMMUNITY DEVELOPMENT DEPARTMENT APPROVAL Engineer's Stamp Conditional Approval: til Date......... stgt+l i�,� 4 H �•, SPURKLAND 1 Approved Date /� Top (� Insnection Reno -1-12 dor. Cat Y AWWTS Alternate silo IO 40' x 5' wide trench 4 feet of sewer rock 400 sf absorption area Max excavation depth 8.5' LO 4 S T. C.O. C 33' 12.5'9:z S T. C.O. D 36' 50' DBL CO. £ 38' 24.5' o DF. C.O. F 57.5' 64.5' a DF. MT. G 55.5' 63' D/: MT H OF. C.O. 1 48' 47' 77' 78' SPUTTER J 64' 71' I DF. C.O. K 66' 78.5' L DF. MT. L 64' 78' SLOW" 2eX m DF. MT. M 65' 94.5' sE eaX DF. C.O. N 64.5' 95' ..,....,,�.. �..,�,. �,,,,,, ISLOPE " 20X "m 4 BL 0 SFR E J A LWE' ZOX T INSTALLED 4 -BEDROOM SEPTIC SYSTEM 1 INSTALLED 1250 GALLON SEPTIC TANK TRENCH LENGTH 2 X 40 FEET TRENCH WIDTH 3 FEET AUX EXCAVATION DEPTH 8.5 FEET ROCK DEPTH 5.5 FEET COVER 3 FEET NOTE' SLOPES EXCEEDING 25% W£R£ NOT OBSERVED WITHIN 50 FEET DOWN GRADIENT OF THE PROPOSED ABSORPTION FIELD LOCATION. NOTE: THIS 1S NOT A SURVEYED PLAT. WELL & SEPTIC LOCATIONS TAKEN FROM ON-SITE WATER AND WASTE WATER DEPARTMENT DOCUMENTATION. ALL LOCATIONS SHOWN ARE APPROXIAMTE. 25 0 25 50 75 100 125 150 SCALE 1' = 50 FT, 03 V l5TH. AVENANU tN(iINEC.KlIVLi 203 W 1 I 1ANOR"A TERRACE BM 2 LT 4 I I SEPTIC SYSTEM ASBUILT I UE ANCH. AK. 99501 JONATHAN SCHICK RA TE.- AUG 15 2014 (907) 279-3916 PANORANA DRIVE SNEEP 2/3 6R1Dt 2440 PERMIT # 17SPI41090 P13 # 015-092-64 P4NVRAMATERR2?2L4.SC50-4SB.DV6 *%fe- Trench- 11' rain 3' Wide 2 x 40' Long 8.5' Max. Depth 5.5' Sewer Rock 3' Cover Mln. TH LG dLY.�S3' NY P.il QlY-8E8' KYI QlY-J83' wo amzm' Double Clean outs Foundation Clean out Installed 50/50 Flow Splitter /I \ NO SCALE Trench Elevation (TyP) Cleanouts Monitors Silt Barrier Installed 1250 Gallon Septic Tank Double Clean outs R a 5.5 Ft of Septic Rock 1250 GALLON SEPTIC TANK BENCH HARK TOP FOUND47/ON SW CORNER ASSUMED DIVAAON 100 FEET ISPURKLAND ENGINEERINGI I PANORAMA TERRACE BLK 2 LT 4 I I SEPTIC SYSTEM ASBUILT 203 W 15TH. .4 VENUE ANCH. AK. 99501 JONATHAN SCHICK BA TE, APR 23 2014 (907) 279-3916 PANORAMA BRIVE SHEEP 3/3 GRID, 2440 PERMIT # OSP141080 P1B # 015-092-64 PANOR4MA7£RRB2L4.B3-ASB.BWG Job No. 14-137 0M -W Drilling, Inc. *P.O. Box 110389# Anchorage, AK 99511♦ •907-345-4000 ♦ 907-345-3287 Fax* GROUNDWATER WELL LOG Well Owner: Dittrich Company Use of Well: Domestic Legal Description: Panorama Terrace Lot 4 Block 2 Anchorage AK Drill Method: Air rotary Hole Size: 6" Hole Depth: 161' Casing Size: 6" Cased to: 161' Material: A53B Wall: .250 Well Completion: Open end x Screen Perforated Method. Screen/Perforation description: Grout Notes: ( 2 ) Sack(s) of Bentonite Well Development: Air rotary Well Disinfected: Y Method: Bleach Yield test at 10 GPM for 3 hour(s) with r Method: Submersible pump Sta W r Lev Start Date: Completion Dat : a Iy Test Pump Date: Final Pump Install Dat 9/17/14 WELL LOG (DD) from stati 3WL): 126.4' Depth in feet from top of casing Details of formations penetrated, size of material, color and miscellaneous details. 0 TO 3 Casing Stick Up 3 TO 20 _ __._- -.-.-.- Gravel: silty, large rocks, dry 20 To 30 ............----.--. . .......... .- Boulders large 30 TO 40 - Boulders. lar a with sand g 40 TO 55 _ 55 TO 66 Gravel small mixed with boulders, clay strin gers 60 0- 62 - ........ ...... ---- Sand 62 TO 63 - _ --. -_-----.-.-_-_ -----_ -.-.- Clay 63 ---- To --- 100 --- Sand: Interbedded with sand WATER Qt)ALBTi' TESTiPiG 100 TD 122 ------------ Sand f;oidorrrt Gol/1 - 122 TO 124 - ... Boulder large 1 s. _.... fngA - -.__ Arsenic ug - 124 TO 140 Sandy mixed with medium gravel, dry 140 - TO 143 Clay: wet, silty 143 TO 151 -.-.-. -- silty,-----sandy _ -. -- -.-.- -.-.- ---.-.-... Clay: moist � , 151 TO 161 Gravel. large, water bearing ........... . TO President, M -W Drilling, Inc. NGWA Certified Master Groundwater Contractor Ak Gen Contr Lie No 1000 Pump Installation Date: 9/17114 Pump Intake Depth Below Top of Well Casing: 132.7 feet Pump Manufacturer's Name: Orundfos Pump Model: 10SQE07-240 Pump Size .75 hp Pitless Adapter Burial Depth: 12.7 feet Pitless Adapter Manufacturer's Name: Campbell Pitless Adapter Installer: Mw Drilling, Inc. Well Disinfected Upon Completion? 0 Yes ❑ No Method of Disinfection: Bleach Comments: Pump Installer Name: Mw Drilling, Inc. Attention: The pump installer shall provide a pump installation log to the DSD within 30 days of pump installation. Development Services Department Building Safety Division On -Site Water & Wastewater ProgramBF 4700 Elmore Rood k P.O. Box 196650 a Mark Begich Anchorage, AK 99507 s ^ E r Mayor www.muni.org/onsite (907) 343-7904 Pump Installation Log Well Drilling Permit Number: SW OSP141080 Date of Issue: 4/24/14 Parcel Identification Number: 015 092 64 Legal Description Property Owner Name & Address: Lot 4 Block 2 Panorama Terrace Jonathan Schick & Shawna Rider 5500 Rabbit Creek Rd Anchorage AK 99516 Pump Installation Date: 9/17114 Pump Intake Depth Below Top of Well Casing: 132.7 feet Pump Manufacturer's Name: Orundfos Pump Model: 10SQE07-240 Pump Size .75 hp Pitless Adapter Burial Depth: 12.7 feet Pitless Adapter Manufacturer's Name: Campbell Pitless Adapter Installer: Mw Drilling, Inc. Well Disinfected Upon Completion? 0 Yes ❑ No Method of Disinfection: Bleach Comments: Pump Installer Name: Mw Drilling, Inc. Attention: The pump installer shall provide a pump installation log to the DSD within 30 days of pump installation. On -Site Water & Wastewater System Permit MUNICIPALITY OF ANCHORAGE Development Services Department On -Site Water & Wastewater Program 4700 Elmore Road, PO Box 196650 Anchorage, AK 99519-6650 Telephone: (907) 343-7904 Permit Number: OSP141080 Tax Code Number: 01509264000 Work Type: WellSeptic Initial Permit Effective Dates: April 24, 2014 to April 24, 2015 Design Engineer: SPURKLAND ENGINEERING Subdivision: PANORAMA TERRACE Site Legal Address: PANORAMA TERRACE BILK 2 LT 4 G:2440 Owner/Address: SCHICK JONATHAN S & RIDER SHAWNA M 5500 RABBIT CREEK ROAD ANCHORAGE AK 995164941 Site Mailing Address: 9200 Panorama DR, Anchorage This permit is for the construction of: Y Disposal Field Y Septic Tank N Holding Tank Lot Size in Sq Ft: 51401 Total Bedrooms: 4 N Privy Y Private Well N Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80). 3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either: A. Open and Close on the same day. B. Covered, sealed, and heated to prevent freezing. Received By: Issued By: MUNICIPALITY OF ANCHORAGE Community Development Department Phone: 907-343-7904 Development Services Division Fax: 907-343-7997 On -Site Water & Wastewater Program®■ ■BMITT aA L ON-SITE SEWER/WELL PERMIT APPLICATIO APR 2120144 Gretchen Stuller Parcel I.D. 015-092-64 Property owner(s) JOHNATHAN SCHICK Day phone 317-7505 Mailing address 5500 RABBIT CREEK ROAD, ANCHORAGE, AK 99516 Site address PANORAMA DR. Legal description (Sub'd., Block & Lot) PANORAMA TERRACE BLOCK 2 LOT 4 Legal description (Township, Range & Section) Lot Size Sq. Ft. Number of Bedrooms 4 APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (® all that apply) Absorption Field Fx] Initial R Single Family (SF) 0 (w/wo ADU) Septic Tank Q Upgrade ❑ Duplex (D) ElHolding Tank ElRenewal ❑ Multiple Dwellings ❑ Privy ❑ (SF and/or D) Private Well Water Storage ❑ THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicpble Municipal Codes. kn owner or Permit/Rush Fees: I WL Waiver Fees: Date of Payment: t4f2i'114 Date of Payment: Receipt Number: 6661f14 Receipt Number: Permit No. 0Sp/41026 Waiver No. Permit App_9-1-12.doc SpuMaimd Engonee ong Environmental Consulting and Design SEPTIC SYSTEM DESIGN Municipality of Anchorage April 23, 2014 Development Services Department On Site Water and Wastewater Program 4700 Elmore Road Anchorage, Alaska 99519 Subject: Septic System & Well Installation Permit Panorama. Terrace Block 2 Lot 4 Ladies and Gentlemen: I am writing to request a well & septic system installation permit for the above referenced property. The new installation will serve a proposed 4 -bedroom single-family residence. Soil logs, design calculations, a site plan, design drawings and construction specifications are enclosed for your review. Design Cates: Groundwater observed to a depth of 12.5 feet below ground surface in TH #2 (5/9/12)*. Soil Rating. From Testhole #2 10/18/13 9.3 min/in = 0.8 gal per sq.ft/day No. of Bedrooms 4 Required Area per Bedroom: 150/ 0.8=187.5sq.ft. Total area required: 187.5 x 4 = 750 sgft System: We are proposing a 1250 gallon steel septic tank followed by a deep trench absorption field. The absorption field will consist of two 3 foot wide trenches which will be 40 feet long and contain 5.5 feet (880 sq.ft. effective) of sewer rock. They will be connected by a 50/50 flow splitter. Soils: Test holes were initially excavated by Gamess Engineering on April 0, 2012 See the attached soil logs. Spurkland Engineering performed our own percolation test near test hole 42 on October 18th, 2013 to confirm the data gathered by Garness. Ground water monitoring will continue through construction of the septic system. Groundwater was not observed in either test hole on October 18th, 2013. *Garness Engineering observed ground water at 9.5 feet in test hole 91, but ground water was observed at 12.5 feet in test hole #2. The proposed system is designed outside of the 30 foot radius of test hole #1. 203 West 15th Avenue Suite 203, Anchorage, AK 99501, Phone: (907) 279-3916 Fax: (866) 354-1597, Lspurkland@gci,net Ad& SPUMand EnVnewomp Environmental Consulting and Design Surface Water: There are no surface waters within one hundred feet of the proposed septic system upgrade. Topography: The ground level slopes down towards the west at a consistent 20% grade. Waivers: None Well: The well will be located on the northern edge of the property in such a place to not impede future septic system installation at Conifer Heights Block 1 Lot 21 across the street. The installation of this septic system will not prevent wells and septic systems from being installed on the adjacent lots. The proposed septic system will not change the general slope of the area. Ponding and/or concentration of surface runoff will not result from this installation. If you have any questions or concerns, please contact me at 279-3916. Sincerely, A7 Lars parkland, P.E. Civil Engineer 203 West 15th Avenue Suite 203, Anchorage, AK 99501, Phone: (907) 279-3916 Fax: (866) 354-1597, Lspurkland@gci.net LODGE POLE CT FT/2N R3W SEC 13 PARCEL 1fA \ ego On (\�d LOT 4` BfXILT 2FER lGHTS \ I I $ \ \ 1 I c \\ ` A I � CONIFER HEIGHTS RLK f LT 22 s ® I \ Q LO 3 ® i RRp E W ti LOT 5 \ 2 LOT 2p VACANT \ I RpM 1 O N PI I ." LOT 1A NOTE. THIS IS NOT A SURVEV£D PGT. WELL & SEPTIC LOCATIONS TAKEN FROM ON-SITE WATER AND WASTE WATER DEPARTMENT DOCUMENTATION. ALL LOCATIONS SHOWN ARE APPROXIMATE. 50 0 50 100 150 200 250 300 SCALE I' = 100 FT, SPURKLAND ENGINEERING PANORAMA TERRACE BU 2 LT 4 SEPTIC SYSTEM DESIGN 203 V 15771 AVENUE JONATHAN SCHICK BA TE.- MAR 13 2014 ANCH. AK. 99501 (907) 279-3916 1 PANORAMA DRIVE AND LODGE POLE CT SHEEP 1/3 GRID: 2440 PERMIT R 17SPIIIOXX PID # 015-092-64 PANORAMATERB2L4.SC100.DVG Calx 5' wid Alternate site P \ 40' x 5' wide trench \ 4 feel of sewer rock ` 400 sf absorption area ` Max excavation depth 8.5' LOT 4 PROPOSED C>\ `I H j supe - Eor. of OPE - 2ox I a �� tLoPE - 2ax "I s IFE - Eax , scop£ - Ear. SLW - oz xX \ 4 BDRM SLOPE - 20x INSTALL 4 -BEDROOM SEPTIC SYSTEM 1� INSTALL 1250 GALLON SEPTIC TANK TRENCH LENGTH 2 X 40 FEET TRENCH MIN 3 FEET MAX EXCAVATION DEPTH 8.5 FEET ROCK DEPTH 5.5 FEET COVER 3 FEET ♦..,".,,,' NOTE., SLOPES EXCEEDING 25X WERE NOT OBSERVED .� .��. OF. WITHIN 50 FEET DOWN GRADIENT OF THE PFIELROPOSED ♦ P �♦ ABSORPTION D LOCA770AL • : Gj..••- 4L 4 t ?si NOTE. THIS IS NOT A SURVEYED PUT. WELL @ SEPTIC - .. ..... ...................... LOCATIONS TAKEN FROM ON-S17E WATER AND WAST£ WATER"..x. DEPARTMENT DOCUMENTATION. ALL LOCATIONS SHOWN ARE Oh0 1APPROXIAMTE.�• •• ••• •• ••••••••••••••••... ' ARS SPURKLAND f �� �, :• •• No. CE 11500PINES 25 - 0 25 50 75 100 125 150•�i ''' . , w:L•••� k.:♦ice SCALE' 1' = 50 FT ��p:::�♦♦ L JYUV 157h.0 L:AVN(i1NL:EKlN(i 203 W 15TH. I ( PANORAMA TERRACE BLK 2 LT 4 I I SEPTIC SYSTEM DESIGN ENUE ANCH. AK. 99501 JONATHAN SCHICK DATE+ APR 23 2014 (907) 279-3916 PANURAMA DRIVE SHEET, 2/3 GRID, 2440 PERMIT # USP141080 PlD It 015-092-64 PANORAMATER02L4.SC500W6 Wide Trench+ 11' rain 3' Wide 2 x 40' Long 85' Max, Depth 5,5' Sewer Rock 3' Cover Min, Double Clean outs Foundation Clean out /I I Install 50/50 Flow Splitter \ Install 1250 Gallon Septic Tank NO SCALE Trench Elevation (TyP) Double Clean outs Cleanouts 5.5 Ft of Septic Rock 1250 GALLON SEPTIC TANK ISPURKLAND ENGINEERINGI I PANORAMA TERRACE BLIC 2 LT 4 I I SEPTIC SYSTEM ASBU2T 203 W 15TH, AVENUE ANCH. AK. 99501 JONATHAN SCHICK DATE.: APR 23 2014 (907) 279-3916 PANORAMA DRIVE SHEET. 3/3 GRID, 2940 PERMIT N OSP141080 PID H 015-092-64 PANORAMATERRML4,MM Spurkland Engineering 203 W. 15th Ave. Ste. 202A Anchorage, AK99501 TEST HOLE / ---2— DEPTH 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 SOIL LOC AND PERCOLATION TEST SOIL DESCRIPTION DATE._11 J61----- WAS GROUNDWATER OBSERVED: No IF YES, AT WHAT DEPTH.• AFTER MONITORING PERIOD: DATE OBSERVED: —_ 13 PERCOLATION TEST.• FILL DATE I GROSS TIME NET TIME DISTANCE I DROP 7.000" 10118113 1:07 PM 0 min. 6.875 1:37 PM 30 min. 3.6250 3.375 6.938 2.07 PM 30 min. 3.688 3188 2:37 PM 30 m1n. 3.688 3250 PERCOLATION RATE: 9.3 minutes/ Inch PERC HOLE DIAMETER. • 6 inches TEST RUN BETWEEN --3 FT AND FT SITE PLAN: I N a � TH1 A 11 v 11 $ TH LOT 4 I I NOTES- GW MONTIORING DONE IN GEG TEST HOLE. PERC TEST PERFORMED IN EXISTING PERC BENCH ------ -------------------- Presoaked /or 4 hours PERFORMED BY: Anson Moxness. I, Lars Sourkland P.E. CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. SPURKLAND ENGINEERING PANORAMA TERRACE B2 L4 SOIL LOG PERCOLATION TEST 203 V 15TH, AVENUE ANCH. AK. 99501 JONATHAN SCHICK B4 TD MARCH 13 2014 (907) 279-3916 1 PAN17RAMA DR I I GRID #: 2440 PERMIT # PID # 015-92-64 GARNESS ENGINEERING GROUP, Ltd. CONSULTANTS & GENERAL CONTRACTORS SOIL LOG — PERCOLATION TEST LEGAL DESCRIPTION: PANORAMA TERRACE SUBDIVISION; BLOCK 2, LOT 4 PERFORMED FOR: JONATHAN SCHICK DATE: DEPTH �___ ORGANICS (feet) TEST HOLE #1 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 GM TO SM WITH LENSES OF OF ML THROUGHOUT DENSER WITH DEPTH SOIL CLASSIFICATIONS DEPTH TO GROUNDWATER DATE ummummam 4/4/2012 DRY Im�nilii 9.5' 5/9/2012 6" - 2 m mil 30 .� ow I 1:15 111011v", — 4 4 30 WKS 5" 5 DEPTH TO GROUNDWATER DATE DRY 4/4/2012 DRY 4/13/2012 9.5' 5/9/2012 6" - 2 INITIAL PERCOLATION RESULTS ON 4/5/12 WERE RUN BETWEEN 5.5' & 6.5' AT A RATE OF 120 MIN./INCH. PERCOLATION TEST WAS PREFORMED AGAIN ON 5/9/12 BECAUSE INITIAL RESULTS WERE SUSPECT TO HAVE BEEN INFLUENCED BY SURFACE RUN OFF/INFILTRATION SEE ATTACHED SITE PLAN DATE READING CLOCK TIME NET TIME (MINUTES) WATER LEVEL READING NET DROP (INCHES) 5/9/2012 1 12:45 - 6" - 2 1:15 30 0" 6" 3 1:15 — 6" — 4 1:45 30 1 " 5" 5 1:45 — 6" — 6 2:15 30 1-1/2" 4-1/2" 7 2:15 — 6" — 8 2:45 30 1-1/2" 4-1/2" PERCOLATION RATE *6.7 (MIN./INCH) PERC. HOLE DIA. 6 (INCHES) TEST RUN BETWEEN 4.0 FT. AND 5.0 FT. A FOUR HOUR PRESOAK WAS PERFORMED: ® YES ❑ NO SOILS LOGGED BY: JODY MAUS/ROB CAMPBELL PERCOLATION TEST PERFORMED BY: JODY MAUS COMMENTS: *READINGS ARE WITHIN 1/16". DUE TO OVERALL APPEARANCE OF SOILS, RECOMMEND USING A 0.6 APPLICATION RATE. PERFORMED BY GEG, Ltd. I, JEFFREY A. GARNESS, CERTIFY THAT THIS WASP RF f2MED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE: ( IZ GARNESS ENGINEERING GROUP, Ltd. CONSULTANTS & GENERAL CONTRACTORS SOIL LOG - PERCOLATION TEST LEGAL DESCRIPTION: PANORAMA TERRACE SUBDIVISION; BLOCK 2, LC PERFORMED FOR: JONATHAN SCHICK D DEPTH ���� ORGANICS (feet) TEST HOLE 2 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 GM TO SM WITH LENSES OF OF ML THROUGHOUT DENSER WITH DEPTH SOIL CLASSIFICATIONS DEPTH TO GROUNDWATER DATE DRY 4/4/2012 DRY 4/13/2012 DRY TO 12.5' 5/9/2012 6" — 2 nurmi 30 0" 6- 3 1:16 — 6" — 4 /y�/�y/�pM 30 F+ 5-1/2" 5 DEPTH TO GROUNDWATER DATE DRY 4/4/2012 DRY 4/13/2012 DRY TO 12.5' 5/9/2012 6" — ,� ICE -7973 • S/,l g l.y',,� Prof a ssio�6 INITIAL PERCOLATION RESULTS ON 4/5/12 WERE RUN BETWEEN 5.5' & 6.5' AT A RATE OF 120 MIN./INCH. PERCOLATION TEST WAS PREFORMED AGAIN ON 5/9/12 BECAUSE INITIAL RESULTS WERE SUSPECT TO HAVE BEEN INFLUENCED BY SURFACE RUN OFF/INFILTRATION. THERE WAS AN OBSTRUCTION AT 12.5' IN THE MONITORING TUBE THAT DID NOT ALLOW US TO VERIFY TOTAL DEPTH TO GROUNDWATER ON 5/9/12. SEE ATTACHED SITE PLAN DATE READING CLOCK TIME NET TIME (MINUTES) WATER LEVEL READING NET DROP (INCHES) 5/9/2012 1 12:46 — 6" — 2 1:16 30 0" 6- 3 1:16 — 6" — 4 1:46 30 1/2" 5-1/2" 5 1:46 — 6" — _ 6 2:16 30 1" 5" 7 2:16 — 6" — 8 2:46 30 1" 5" 19� PERCOLATION RATE *6.0 (MIN./INCH) PERC. HOLE DIA. 6 (INCHES) TEST RUN BETWEEN 4.0 FT. AND 5.0 FT. 20 A FOUR HOUR PRESOAK WAS PERFORMED: ® YES SOILS LOGGED BY: JODY MAUS/ROB CAMPBELL PERCOLATION TEST PERFORMED BY: ❑ NO JODY MAUS COMMENTS: *READINGS ARE WITHIN 1/16". DUE TO OVERALL APPEARANCE OF SOILS, RECOMMEND USING A 0.6 APPLICATION RATE. PERFORMED BY GEG, Ltd. I, JEFFREY A. GARNESS, CERTIFY THAT THIS WAS PE ORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE: