HomeMy WebLinkAboutRAVEN WOODS BLK 1 LT 9Raven Woods
Block 1
Lot 9
#015-232-07
I% O MUNICIPALITY OF ANCHORAGE ~
DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION
ENVIRONMENTAL ENGINEERING DIVISION
825 L Street- Anchorage, Alaska 99501 Telephone 264-4720
ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT
[~'GRADE
MAILING ADDRESS
LOCATION / NO. OF BEDROOMS
DISTAN
~ ~ Liq. capacity in galJons IF HOME'DE: Inside length ~idth L~quid depth
O Z ~ Manufacturer Material Liquid capacity in gallons
Nearest lot line ~ PERMIT NO.
Q Wail i Foundatior~O t~ ~ ~
~ ~ DISTANCE TO: ~ O~
Length Width Depth PERMIT NO.
~ ~ Type of crib Crib diameter Crib depth Total effective absorption area
~ Well Building foundation Nearest lot line
~ DISTANCE TO:
Building foundation Sewer line Septic tank Absorption area(s~
~ DISTANCE TO:
OTHER
SOl L TEST RATING
72-~13 (Rev, 3/78)
PER[~ I T
~PPL ICRNT PAUL KOPPLIN
.OCATION TRAPPERS TRAIL
LEGAL
TYPE OF SOIL ABSORPTION SYSTEM
MLIF~IC:ZPRLIT~' OF R~CHORRGE
DEPARTMENT F~HERLTH RND ENVIRONMENTAL tTECTION
o~._ L~_TREET., ANCHORAGE,
264-4720
Of4--SITE SEXIER PERMIT
BO,-, ST RT R
LOT SIZE
IS: TRENCH
~44-7291
54000 SQUARE FEET
MAXIMUM NUMBER OF BEDROOMS
SOIL RATING (SQ FT,-'BR)= 178
THE REQUIRED SIZE OF THE SoIL ABSORPTION SYSTEM IS:
C, EPTH= 8 LE~-IGTH= 64 GRR%¢EL C, EPTH= 4
THE LENGTH DIMENSION IS THE LENGTH (IN FEET) OF THE TRENCH OR DRRINFIELD.
THE DEPTH OF R TRENCH OR PIT IS THE DISTANCE BETWEEN THE SURFACE OF THE
GROUND AND THE BOTTOM OF THE EXCAVATION (IN FEET).
THERE IS NO SET WIDTH FOR TRENCHES.
THE GRRVEL DEPTH IS THE MINIMUM DEPTH OF GRAVEL BETWEEN THE OUTFRLL PIPE
AND THE BOTTOM OF THE EXCAVBTION (IN FEET).
REQLI I RED SEPT I C TFt[,tK S I ZE= 1OOO GFtLLO[,tS
PERMIT 8PPLICRNT HAS THE RESPONSIBILITY TO INFORM THIS DEPARTMENT DURING THE
INSTALLATION INSPECTIONS OF ANY WELLS ADJACENT TO THIS PROPERTY AND THE
NUMBER OF RESIDENCES THAT THE WELL WILL SERVE.
TWO < 2 :-" INSPECT I OI'-~S FIRE REQ~J I F.'ED
BREmKFILLINu OF ANY _,~_,TEM WITHOLIT FINAL INSPECTION AND APPROVAL BY THIS
DEPARTMENT WILL BE SUBJECT TO PROSECUTION
MINIMUM DISTANCE BETWEEN A WELL AND ANY ON-SITE SEWRGE DISPOSAL SYSTEM IS
100 FEET FOR A PRIVATE WELL OR 150 TO 200 FEET FROM R PUBLIC WELL DEPENDING
UPON THE TYPE OF PUBLIC WELL.
MINIMUM DISTANCE FROM A PRIVATE WELL TO R PRIVATE SEWER LINE IS 25 FEET END
TO R COMMUNITY SEWER LINE IS 75 FEET.
OTHER REQUIREMENTS MAY APPLY. SPECIFICATIONS AND CONSTRUCTION DIAGRAMS ARE
AMRILABLE TO INSURE PROPER INSTALLATION.
PERfd I T E~2P I RES DECEf~BER ~1.. 1988
I CERTIFY THAT
i: I AM FAMILIAR WITH THE REQUIREMENTS FOR ON-SITE SEWERS AND WELLS RS SET
FORTH BY THE MUNICIPALITY OF ANCHORAGE.
2: I WILL INSTRLL THE SVSTEM IN ACCORDANCE NITH THE CODES,
~: I UNDERSTAND THAT THE ON-SITE SEWER SYSTEM MRV REQUIRE ENLARGEMENT IF THE
RESIDENCE IS REMODELED TO INCLUDE MORE THAN ~ BEDROOMS,
...........
PAUL PLIN
ISSUED BY_7'''/. __DATE___ 0 Y4.0
MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH AN.D ENV~ RONMEI~ITAL PROTECTION
SOILS LOG - PERCO LATIOIJ TEST
SOILS LOG
PERCOLATION
TEST
LEGAL DESCRIPTION:
DATE PFRFORMED:~
2
3
4
SLOPE SITE PLAN
5
7
10
11
12
13
14
15
16
17
18
19
20-
WAS GROUND WATER
IF YES. AT WHAT
DEPTH?
Reading Date G~oss Net Depth to Net
PERCOLATION RATE
PERFORMED i ~ERTI FI ED BY: DATE: ...?"