No preview available
HomeMy WebLinkAboutRAVEN WOODS #1 BLK 4 LT 9I aven Woods Block 4 Lot 9 #015-232-24 BOR~GH Department of Environmental Quality 3330 C Street Anchorage, Alaska 99503 INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM NAME ADDRESS '0 P,ONE SEPTIC TANK: DISTANCE (~ NUMBER OF FROM WELL MANUFACTURER .-'/'~'""'~4'~ MATERIAL COMPARTMENTS INSIOE WIDTH LIQUID DEPTH INSIDE LENGTH LIQUID CAPACIT~'~'''D GALLONS. TILE DRAIN FIELD: ~~ DISTANCE FROM WELL FOUNDATION NEAREST LOT LINE TOTAL LENGTH OF LINES NUMBER OF LINES DISTANCE BETWEEN LINES TRENCH WIDTH IN. TOTAL EFFECTIVE ABSORPTION AREA ~'~' SQ. FT, LENGTH OF EACH LINE DEPTH OF FILTER f DEPTH: TOP OF TILE TO FINISH GRADE MATERIAL BENEATH TILE ~ IN. ABOVE TILE IN. WELL: BUILDING FOUNDATION __ CESSPOOL APPROVED CONSTRUCTION DEPTH NEAREST NEAREST SEPTIC SEEPAGE LOT LINE SEWER LINE TANK , SYSTEM · OTHER SOURCES DISAPPROVED REMARKS DISTANCE FROM: DISTANCES: INSTALLED BY: SEWER LINE DEPTH: PiPE MATERIAL' LOT SLOPE: REMARKS: DIAGRAM OF SYSTEM DATE ~. I~ ~)~'"~ APPROVED G.A.A.B. Form EQ-032 · '~ 'NLIN I C: I PRL I T~¢ OF i:t~C HORF~GE DEPBRTMENT OF HERLTH RND ENV!RONMENTRL PROTECTION ~JELL RNC. ON--SITE SEI4ER F'ERr.1Z T ~ ~RR~NF ~ELDMFTF~ 8618 ERST tRTH LOCRTION ~ILLETTE DR ~ TRRPPERS TRL RD LEGRL L9 B4 RRVEN WOODS SUBD LOT SIZE 78525 SQFT TYPE OF SOIL 8BSORPTION S~STEM... PIT NUMBER OF BEDROOMS 4 SOIL RRTING, SQFT/BR THE REQUIRED SIZE OF THE SOIL RBSORPTION SYSTEM IS:DEPTH= i2 ~ENGTH= THE MINIMUM DEPTH OF GRRVEL BETWEEN THE OUTFRLL PIPE 8ND THE EXCRVRTION BOTTOM IS 6 FT THERE IS NO SET WIDTH FOR TRENCHES. FOR DRAINFIELDS, THE WIDTH IS ~FT. THE DEPTH OF TRENCH OR PIT IS THE DISTBNCE BETWEEN THE GROUND SURFRCE RND THE BOTTOM OF THE EXCAVRTION. THE LENGTH DIMENSION IS THE LENGT~ OF EACH SIDE FOR R SEEPAGE PIT OR THE LENGTH OF THE TRENCH, OR DRRINFIELD. THE REQUIRED SEPTIC TRNK SIZE IS i250 GRLLONS BACKFILLING OF ANY SYSTEM WITHOUT FINBL INSPECTION BY THIS DEPRRTMENT WILL BE SUBJECT TO PROSECUTION. MINIMUM DISTANCE FROM WELL TO ANY SEPTIC TANK?PRCKRGE PLRNT OR SOIL 8BSORPTION SYSTEM IS i00 FT FOR R PRIVRTEWELL 8ND 200 FT FOR 8 PUBLIC WELL. WELL LOGS MUST BE RETURNED TO THE DEPRRTMENT WITHIN 30 DRYS OF THE WELL COMPLETION. SPECIFICRTIONS RND CONSTRUCTION DIRGRAMS ARE AVRILRBLE TO INSURE PROPER INSTRLLRTION. I CERTIFY THRT IRM FRMILIAR WITH THEREQUIREMENTS- FOR ON-SITE SEWERS RND WELLS AS SETFORTH BY THE MUNICIPALITY OF RNCHORRGE 8WD WILL INSTALL IN RCCORDRNCE WITH THE CODE. 'JAMEB B, ROBER ~:ONSULTING ENGINEER AND SURVEYOR 344-8270 PHONE: (907) ~/~ TELEX: NORTRADE ANCHORAGE, ALASKA 99503 1200 W, Dimond - 614 CERTIFICATION OF PERCOLATION RATE I, the undersigned registered civil engineer, do hereby certify that I have made a standard percolation test in accordance with U. S. Public Health Service Publication No. 526 on Lot 9 Block 4 of Raven Woods Subdivision, Addition No. 1 at the location of the proposed drain field shown on the proposed plot plan of said lot, a copy of which is attached hereto, and that the percolation rate has been determined by me to be 3.3 minutes per inch. Gradat±on of soil remains constant sandy gravel to a depth of at least 33 feet with no ground water. Date James B. Roberts, P. E. Registered Civil Engineer Alaska Reg. No. 1516-E American Society of Civil Engineers $ American Congress on Surveying and Mapping $ Alaska Society of Professional Land surveyors WATER WELL LOG MUNICIPALITY Ot= ANCHORAGE DEPT. OF H.A.Tt-. ~ ENV;RONMENTN. PROTEClJOI~ POSS DRILLING JUN 2 13~6 Ingra Street - ,~or.~e. ,~.~ ~0~ ~ ~RECEI~ED f ~/~.~ r uss o~ SIZE O~ CA~I.~ STATIC .ATER L~EL /~ O ~. YIE~G~.PER.MIN. WITH. FE~ OP D~OWN. DATE COMPLET~ o.,J5 PUMP TO BE SET AT ,tO .__to .___to .__to tO~ .___to to to to GREATER ANCHORAGE AREA BOROUGH Department of Environmental Quality 3330 "C" Street, Anchorage, Alaska 99503 274-4561 Date Received Septe~er 23, 1976 Time of Inspection Date of Inspection REQUEST FOR APPROVAL OF INDIVIDUAL SEWER & WATER FACILITIES FOR Conv. Appr0va] requested by: First National BAnk of Anchorage Mailing Address: Property Owner: Mailing Address: Post Office Box 720 Edward & Marlene Feldmeier 3. Legal Description: 4. Location: Trap~)ers Way 5. Type of facility to be inspected '6. Well Data: Individual A. Type Phone: 279-4481 x 482 Star Route Lot 9 Block 4 Ravenwood Subdivision No. of bedrooms C. Construction Sewage Disposal System: A. Installed 1976 C. Septic Tank: 1. Size D. Seepage Pit: E. Disposal Field: Single Family B. Depth D. Bacterial Analysis On-site system B. Installer 2. Manufacturer 2. Material 1. Absorption Area Total length of lines , Sewer Lines , e e Distances: A. Well to: Septic tank Nearest lot line B. Foundation to septic tank , Absorption area , Other contamination , Absorption area C. Absorption area to nearest lot line EQ-034 (1774) Page 1 of two pages Page 2 of two pages ~ st for Approval of Individual & Water Facilities # 'Lega~ Description Lot 9 Block 4 Ravenwood Subdivision Comments Approved Approval~Valid for one year from date signed Greater Anchorage Area Borough, Department of Environmental Quality DIAGRAM OF SYSTEM I certify that the information contained in this request for approval to be a true and accurate representation of the subject sewer and water facilities and these facilities are operating satisfactorily. SIGNED Date EQ-034 (1/74) MUNICIPALITY OF ANCHORAGE DEPARTMENT OF ENVIRONMENTAL QUALITY 3330 "C" Street, Anchorage, Alaska 99503 274-4561 REQUEST FOR APPROVAL OF INDIVIDUAL SEWER and WATER FACILITIES 1. Type of Inspection: CMRO . VA 2. Property Owner: Edward and Marlene Feldmeier FHA CONV X Mailing Address: Star Route Trappers Way 3. Name of Buyer: same as above Day Phone 349-1951 Mailing Address: Day Phone Name of Lending Institution: First National Bank of Anchorage Mailing Address: 5. Name of Realtor or Agent: none Mailing Address: P.O. Box 720 Phone 279-4481 Ext 482 Phone Legal Description: Location: Lot 9 Blk ~ Raven Woods Sub #1 Star Route Trappers Way 7. Type of Facility to be inspected: 8. Water Supply Type of Supply: Single Family Public Utility No. Bdrms. 4 Individual y If Individual, number of dwellings presently served If Individual, depth of well Sewage Disposal System Type of System: Public Utility If Individual, date of installation 1976 Individual (on-site) EQ-037 (1/74)