HomeMy WebLinkAboutVICKERY LT 1AVickery
Lot 1 A
#017-441-63
Inspection Report 1-1-12.doclrl
Municipality of Anchorage
Community Development Department Page 1 of 3
On -Site Water and Wastewater Program
4700 Elmore St. • P.O. Box 196650 Anchorage, AK 99519-6650 • http:/Iwww.muni.org/onsite • (907) 343-7904
ON-SITE WASTEWATER INSPECTION REPORT
Permit Number: OSP141132
PID Number: 017-441-83 New ❑ Upgrade
Name:
John Hagmeier
ABSORPTION FIELD
❑✓ Deep Trench ❑ Shallow Trench ❑ Bed ❑ Mound
Address
6040 Huffman Road
❑ Other
Phone
Number of Bedrooms
Soil Rating
Total depth from original grade
6
1 GPD/SF
8.0 Ft.
LEGAL DESCRIPTION
Depth to pipe invert from original grade
3.0 Ft.
Gravel depth beneath pipe
5.0Ft.
Subdivision
Block Lot
Vickery
1A
Fill added above original,grade
1.0 Ft.
Gravel length
90.0 Ft.
Township Range Section
Gravel width
3.OFt,
Beds: Number of Lines
NIA
Distance between lines
N/A Ft.
SEPARATION DISTANCES
To
Septic
Absorption
Lift Station
Holding
Sewer
Total absorption area
Number of trenches
Dist. between trenches
From
Tank
Field
Tank
Line
900 z
Ft
2
10.0 Ft
Well
118.5
126.5
NIA
N/A
gg,4
TANK ElSeptic ❑ S.T.E.P. ElHolding ❑ Other
Manufacturer -
Anchorage Tank
Capacity
I 2000Gal.
Surface Water
100+
100+
N/A
N/A
Material
Number of compartments
Lot Line
65.8
41.9
N/AN/A
STEEL
2
NA
Foundation
27.0
39.6
N/A
N/A
LIFT STATION
Manufacturer
Capacity
Curtain Drain
50+
50+
N/A
I N/A
Gal.
Remarks
Pump on level at
in.
Pump off level at
in.
High water alarm at
in.
-
Pump make and model
Electrical Inspections performed by
-
Installer
PIPE MATERIAL House to tank 3034 drainfield Tank to
3034
John Hagmeier Homes
Drainfield 3034 CO/MT 3034
Inspector Pannone Engineering Services
BENCH MARK (Assumed elevation) 100ft
InspectionLocation
1 11/12/14
11/13/14
and description
dates:
2d
Garage FF
Td
41h
COMMUNITY DEVELOPMENT DEPARTMENT APPROVAL
Engineer's Stamp
�titit\
0111.......
Conditional Approval:
Date
,;,
TH
t1e'veii A annorae'/T
CE 2149.,-
i
Approved
Date
Inspection Report 1-1-12.doclrl
HUFFMAN ROAD
M l
\� — — • �=1 • • — RESERVE DRAIN FIELD (P) /
s 10' T&E ESMT�� — 45LE xx 5'ED x 8'TD
BASED ON
CAT III �
;\ 47.9 42'7 PROPOSED SEPTIC r/
o.oC2 — _ AREA.
C4 I o
1i
NEW DRAIN FIELD M4 „ My = �
(2EA) 45LF x 3'W x 5'ED x 8'TD 10.0 I _
3 TH-4 1 NEW 2000g SEPTIC TANK F
195.0 \01 C1 W� DCO AND FS �. I
TO WELL ' C3
\w _ —
57.4 — T1
_ FS
LOT UNDEVELOPED _ • DCO T2
NO WELLS OR SEPTICS
ON THIS LOT FCO j
A
NEW
'v
� OR HOUSE '
\�
3 \\
iI NEW WELL
TH-1 _/� I TH
TH3
i
NOTES:
A
B C
T1
30.3
29.9 —
T2
38.9
31.0 —
DCO
41.7
32.4 —
C1
50.7
40.5 —
M 1
53.9
43.7 —
C2
88.9
83.4 —
M1
86.3
80.2 —
C3
62.0
48.0 —
M3
66.1
52.8 —
C4
95.6
87.5 —
M4
92.6
83.9
WELL
—
91.7 47.5
NOTES:
`
`��� \\
r �. �F. A�gsl�+
%g�p Fyo)
TH * 0.
%""•"
/ Steven R. •Pannope
f+PF. CE 8149
�ll� oFESSi
Date
1/6/2015
LOT UNDEVELOPED
/
Scale
1"=50'
P.I.D. NO
17-441-63
NO WELLS OR SEPTJSS
\
PERMIT NO.
OSP141132
ON THIS LOT -"
meet
�g
EA (E)7,1HCOUSE
✓
M �M
\M
M
NOTES:
P.00. BO 1j000022117 ANCHORAGE, 99 10
PHONE (907) 272-8218 FAX (907) 272-8211
`��� \\
r �. �F. A�gsl�+
%g�p Fyo)
TH * 0.
%""•"
/ Steven R. •Pannope
f+PF. CE 8149
�ll� oFESSi
Date
1/6/2015
RECORD DRAWING
Scale
1"=50'
P.I.D. NO
17-441-63
VICKERY, LOT 1A
6040 HUFFMAN ROAD
JOHN HAGMEIER
2204 CLEVELAND AVE #201'1c/j•�'
ANCHORAGE, AK 99517
PERMIT NO.
OSP141132
PLAN
meet
SPECIAL PROVISIONS TO SPECIFICATIONS
1. ALL CONSTRUCTION WAS INSTALLED AS SPECIFIED IN THE MOST CURRENT EDITION OF THE MUNICIPALITY OF ANCHORAGE
STANDARD SPECIFICATIONS (MASS) FOR COMPONENT PARTS AND MATERIALS USED IN CONSTRUCTION OF ON—SITE
WASTEWATER DISPOSAL SYSTEMS AND THE ATTACHED SPECIFICATION,
3. SCOPE OF WORK: INSTALLED NEW 2000g SEPTIC TANK AND SOIL ABSORPTION SYSTEM.
4. GROUNDWATER WAS NOT ENCOUNTERED AS EVIDENCED BY THE SOIL TEST HOLE. AN APPARENT WATER TABLE WAS NOT
OBSERVED IN ANY OF THE EXCAVATIONS LESS THAN 16.0 FEET BELOW EXISTING GRADE-.
NO GROUND WATER
MONITORED ON 10/1
0
SM
93.7
SW
5.0
88.7 L
SKI
SM
8.0
GM
0
0
z
w
U
IL 995
20009 SEPTIC
TANK
LEGEND
—w—w—w WATER LINE/
WELL RADIUS
—ss—w— NEW SEPTIC
ER FABRIC
0 DRAIN PIPE
)RAIN ROCK 6" ABOVE PIPE INV
— 93.7
ROCK
DESIGN PARAMETERS
PRIMARY SEPTIC SYSTEM
NO. BEDROOM: 6 (900 gpd)
TANK SIZE: 2000g SEPTIC
PERC RATE = 1 MPI
SOIL RATING: 1.0 GPD/SF
AREA ROD: 900SF
SYS. TYPE: DEEP TRENCH 5'ED
MIN LENGTH: 90 LF
USED:
2EA 45LFx3'Wx5'EDx8.0"TD
TOTAL AREA: 900 SF
NOTES: PANNONE ENG SVC, LLC
RECORD DRAWING P.O. BOX 100217 ANCHORAGE, AK 99510
PHONE (907) 272-8218 FAX (907) 272-8211
VICKERY, LOT 1A
6040 HUFFMAN ROAD
JOHN HAGMEIER
DESIGN DETAILS 2204 CLEVELAND AVE #201
ANCHORAGE, AK 99517
ABBREVIATIONS
CU
97.7
DIP
DUCTILE IRON PIPE
TH
96.7
T 93.7 NE/W)
s
FC
—10.0
RESERVE SYSTEM SIMILAR
ate.
ONE TRENCH ONLY.
CLEAN OUT NO.
w M
FILTER FABRIC r
wo
r4" 0 DRAIN PIPE z o
up O w
w a II ROCK O W
n RD
IDRAIN
w o 1 o ABOVE PIPE INV o w
DESIGN PARAMETERS
PRIMARY SEPTIC SYSTEM
NO. BEDROOM: 6 (900 gpd)
TANK SIZE: 2000g SEPTIC
PERC RATE = 1 MPI
SOIL RATING: 1.0 GPD/SF
AREA ROD: 900SF
SYS. TYPE: DEEP TRENCH 5'ED
MIN LENGTH: 90 LF
USED:
2EA 45LFx3'Wx5'EDx8.0"TD
TOTAL AREA: 900 SF
NOTES: PANNONE ENG SVC, LLC
RECORD DRAWING P.O. BOX 100217 ANCHORAGE, AK 99510
PHONE (907) 272-8218 FAX (907) 272-8211
VICKERY, LOT 1A
6040 HUFFMAN ROAD
JOHN HAGMEIER
DESIGN DETAILS 2204 CLEVELAND AVE #201
ANCHORAGE, AK 99517
ABBREVIATIONS
CU
97.7
DIP
DUCTILE IRON PIPE
TH
96.7
T 93.7 NE/W)
s
FC
WA,
T#
ate.
C#
CLEAN OUT NO.
M#
MONITOR TUBE NO.
R.I.
RIGID INSULATION
DCO
DOUBLE CLEAN OUT
DV
DIVERTER VALVE
DESIGN PARAMETERS
PRIMARY SEPTIC SYSTEM
NO. BEDROOM: 6 (900 gpd)
TANK SIZE: 2000g SEPTIC
PERC RATE = 1 MPI
SOIL RATING: 1.0 GPD/SF
AREA ROD: 900SF
SYS. TYPE: DEEP TRENCH 5'ED
MIN LENGTH: 90 LF
USED:
2EA 45LFx3'Wx5'EDx8.0"TD
TOTAL AREA: 900 SF
NOTES: PANNONE ENG SVC, LLC
RECORD DRAWING P.O. BOX 100217 ANCHORAGE, AK 99510
PHONE (907) 272-8218 FAX (907) 272-8211
VICKERY, LOT 1A
6040 HUFFMAN ROAD
JOHN HAGMEIER
DESIGN DETAILS 2204 CLEVELAND AVE #201
ANCHORAGE, AK 99517
ABBREVIATIONS
CU
COPPER
DIP
DUCTILE IRON PIPE
TH
TEST HOLE
FC
FOUNDATION CLEAN OUT
T#
TANK CLEAN OUT NO.
C#
CLEAN OUT NO.
M#
MONITOR TUBE NO.
R.I.
RIGID INSULATION
DCO
DOUBLE CLEAN OUT
DV
DIVERTER VALVE
FS
FLOW SPLITTER
BEG
BELOW FINISH GRADE
OG
ORIGINAL GRADE
FG
FINISH GRADE
TS&V
TOPSOIL & VEGETATE
OF ASA`kWI, 1/6/2015
TM NTS
... .. .. .... / P.I.D. No
017-441-63
Steve
CE 8149 Pannone PERMIT NO.
CE / OSP141132
Sheet1i�>4ryRO[{5 4
3 OF 3
69/19/2614 22:53 96/-34b-6262 ALPINE DKILL1NU PAUL UI/bl
Alpine Drilling & Enterprises
Well Log
Permit Number: #SW 141932 Date of Issue: 6-29-14 Parcel Identification Number: 01744163000
Date Started: 9-20-14 Date Completed: 9-23-14 is well located at approved permit location? x Yes ❑ No
Legal Description: Vickery Lot 1 A
Property Owner Name & Address: Hagmeier John & Judith A
DBA John Hagmeier Company 2204 Cleveland Avenue #201
n .,..h...-o.�o Alacka QQA17
Borehole Data:
Soil 'type, Thickness & Water Strata
v Depth (ft) M V
From To
Method of Drilling x air rotary ❑ cable tool
Casing type: steel
Stick-up
silt
0 2
2 7
Wall Thickness; .250 inches
Diameter: 6 inches Depth: 166 feet
Liner Type:
gravelly silt
7 46
Diameter: inches Depth: feet
sandy gravelly silt
46 71
Casing stickup above ground: 2 feet
gravelly silt
silt
71 122
122 136
Static water level (from ground level): 175 feet
Pumping level: 496 feet after
14 hours pumping 3_2 gpm
gravelly silt
136 161
Recovery Rate: 3_2 gpm
bedrock
161 496
Aletbod of Testing: air li
Well Intake Opening Type:
400- 420 F120
E] Open End x Open Hole
❑ screened Start feet Stopped — feet
❑ Perforations Start feet Stopped feet
Grout Type: Bentonite granules Volume: 2 bus
Depth: Start 0 feet Stopped ? feet
Pump: Intake Depth — feet
Pump size _hp Brand Name
Well Disinfected Upon Completion? x Yes ❑ No
Method of Disinfection: chlorine ralllets
Comments: Well produced .75 gpm after original
production. Well was hydrofaced which brought
production up to 3.2 gpm. This is aremake of the original
well log.
Well Driller: Alpine Drilling & Enterprises
PO Box 110496
Anchorage AK 99511
08/15/2014 21:30 907-345-0202 ALPINE MILLING PAGE 01/01
Development Services Department
Building Safety Division
On -Site Water & Wastewater Programs* d
4700 Elmore koad z ;:
P,O, Box 196650
Mark Begioh Anchorage, AK 99507 5 A c Y r
Mey9r www.muni.or@(onsite
(407) 343,7904
Pump Installation Log
Well Drilling Permit Number: SW 14 1132 Date of Issue: 5-29-14
Parcel Identification Number: 01744163000
Legal Description Property Owner Name & Address:
Vickery Loi iA John Hagmeier Company
2204 Cleveland Avenue #201
Anchorage, Alaska 99517
Pump Installation Date: 1Y73f2014
Pump Intake Depth Below Top of Well Casing: 493 feet
Pump Manufacturer's Name: Gowas
Pump Model: 6G515
Pump Sire 1.5 hp
Pitless Adapter Burial Depth: NIA feet
Pitless Adapter Manufacturer's Name: wA
Pitless Adapter Installer: NIA
Well Disinfected Upon Completion? L, 'iter O Ne
Method of Disinfection.
Comments:
Pump lustaller Name: Aaaow Pump & WeIiseeyiw, LLC
P.O. Box 110496
Anchorage, AK 995110496
Please save for your engineer.
'This is needed for your COSA.
Attention: The pump installer shall provide a pump installation log to the DSU within 30 days of pump installation.
On -Site Water & Wastewater System Permit
MUNICIPALITY OF ANCHORAGE
Development Services Department
On -Site Water & Wastewater Program
4700 Elmore Road, PO Box 196650
Anchorage, AK 99519-6650
Telephone: (907) 343-7904
Permit Number:
OSP141132
Tax Code Number:
01744163000
Work Type:
WellSeptic Initial
Permit Effective Dates: May 29, 2014 to May 29, 2015
Design Engineer:
PANNONE ENGINEERING SERVICE
Subdivision:
VICKERY
Site Legal Address: VICKERY LT 1A G:2838
Owner/Address: HAGMEIER JOHN C & JUDITH A
DBA JOHN HAGMEIER COMPANY 2204 CLEVELAND AVENUE #201 ANCHORAGE AK 995173011
Site Mailing Address: 6040 HUFFMAN RD, Anchorage
This permit is for the construction of:
Y Disposal Field Y Septic Tank N Holding Tank
Lot Size in Sq Ft: 49775
Total Bedrooms: 6
N Privy Y Private Well N Water Storage
All construction must be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater
Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80).
3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services
Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either:
A. Open and Close on the same day.
B. Covered, sealed, and heated to prevent freezing.
Received By:
/�-g/10l
Date: t2�
MUNICIPALITY OF ANCHORAGE
Community Development Department Phone: 907-343-7904
Development Services Division Fax: 907-343-7997
On -Site Water & Wastewater Program
ON-SITE SEWER/WELL PERMIT APPLICATION
Parcel I.D. 01-)- 4'Al- 'e 3
Property owner(s) John Hagmeier
Mailing address 2204 Cleveland Ave
Site address NHN Huffman Road
Suite
Legal description (Sub'd., Block & Lot) Vickery S/D Lot 1A
_ Day phone 248-6789
AK 99517
Legal description (Township, Range & Section)
Lot Size 48,775 Sq. Ft. Number of Bedrooms 6
APPLICATION IS FOR:
(M all that apply)
Absorption Field E]
APPLICATION IS AN:
Initial
Septic Tank
El Upgrade
Holding Tank
❑ Renewal
Privy
❑
Private Well
0
Water Storage
❑
0
TYPE OF DWELLING:
Single Family (SF)
(w/wo ADU)
Duplex (D)
Multiple Dwellings
S
AW1A!!
pB'T`f AI and/or D)
MAYIV2�3 2014
THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR:
Distance:
I certify that the above information is correct. I further certify that this is in accordance with
applicable Municipal Codes.
(Signature of property owner or authorized agent)
Permit/Rush Fees: (A - 2A5
Date of Payment: 571,Z -5/i
Receipt Number: 65-14 1
Permit No. 0$e JH ((3 2 -
Pe"it App_9-1-12.doc
Waiver Fees:
Date of Payment:
Receipt Number:
Waiver No.
x❑
1
Pannone Engineering Services LLC
Steven R. Pannone, Principal
Registered Professional Engineer
E-mail: steve(aDoaneneak.com
May 28, 2014
Municipality of Anchorage
Development Services Department
On -Site Water & Wastewater Program
4700 Elmore Road
P. O. Box 196650
Anchorage, Alaska 99519
Subject: Vickery S/D, Lot 1A
Well and Septic System Permit Request
Ladies and Gentlemen:
I am writing to request a permit to install a well and septic system be issued for this property. The
proposed systems will serve proposed six bedroom (6) bedroom house. Currently the lot is undeveloped.
The proposed system will utilize a 2000g Septic tank. The surrounding developed lots are served by
private wells. There are no wells on surrounding lots within 100 feet of this system.
1. Soils. One test hole was performed by Pannone Engineering Services in October of 2013, and
groundwater was monitored for seven days. Ground water was not observed in the test hole after the
seven day monitoring period. It is my opinion, based on the results of the percolation tests and overall
soils appearance; an application rate of 1.0 gallons/day/square feet should be used for a conventional
wastewater system.
2. Soil Absorption System Design.
a. See Sheet 2 of the design package.
3. Surface Water: There is no surface water within 100 feet of the proposed septic tank and drain field.
The proposed drain field upgrade will maintain at least 100 feet from all surface water and drainage
ditches.
4. Topography: The existing topography slopes from the north to the south at approximately 1% in the
area of the proposed drain field. There are no steep slopes in the vicinity of the drain field.
5. Drawing Markings: The Drawings are marked "For MoA Review Only". When written notification that
the review is complete and that there are no further comments is received from MoA On -Site
Department, the note will be removed and `Issued for Construction" drawings will be issued.
Mailing: P.Q. Box 100217, Anchorage, AK 99510-0217
Physical: 332 East Manor, Anchorage, AK 99501
Telephone: (907) 272-8218 FAX: (907) 272-8211
Page 2 of 2
The proposed installation will not affect the future development of the surrounding or existing lots. There
are no surrounding wells within 100 feet of the proposed septic location.
If you have any questions or concerns, please contact me at 272-8218.
Sincerely,
Steven R. Pannone, P.E.
Owner/Civil Engineer
Mailing: P.O. Box 100217, Anchorage, AK 99510-0217
Physical: 332 East Manor Ave, Anchorage, AK 99501
Telephone: (907) 272-8218 FAX: (907) 272-8211
_
.-'ESERVEDRAINFIELD
HUFFMAN ROAD
BASED ON CAT -111 AVVWTS
871)
45 1 )(5'EDx3'W,
,(P) DRAINFIELD
---- --
--
2 EA, 45LFx5'EDx3W, 87D
.....
28.1
.......
LOT UNDEVELOP$D
PROPOSED SEPTIC
W WELLS OR SEI�TICS
AREA.
ON THIS LOT
3;
I�Ni III III
-
TH-4
----------------197.9
61.
TO WELL
/INSTALL F.S.
TANK (PY
WELL P
,B00/9�kEPTIC
NSTALL,DC
I
Z-1 -
6BRHCit( 7-(P)-_::�
Ij
m
I,--,/-
-------
. .....
1A
X
I
/THS
1
TH-:E
,LOT UNDItELOPED
I
TH-3
NOOR SEPTICS
'
0 N.' T
WELL
LOT UNDEVELOPED
\. (P)
NO WELLS OR SEPTICS
i
ON THIS., LOT
�/
SEPTIC AREA
J
HOUSE (E),
NOTES:
PAMONE ENG SVC, LLCDate
Or-. A�...
5/28/2014
FOR
CONSTRUCTION
PHONE
P.O. BOX 100217 ANCHORAGE, AK 99510
(907) 272-8218 FAX (907) 272-8211Scale
• •
TH
.... . . .. .......
... ..
.teve R.. Pa*n'n'o*.n*e,,
p'•. CE 8149
3
VICKERY, LOTS 1A
E. HUFFMAN ROAD
JOHN HAGMEIER
2204 CLEVELAND AVE #201
ANCHORAGE, AK 99517
P.I.D. NO
017-441-51
PERMIT NO.
Ospxxxxxx
PLAN
sheet
1 OF 4
SPECIAL PROVISIONS TO SPECIFICATIONS
1. ALL CONSTRUCTION SHALL BE INSTALLED AS SPECIFIED IN THE MOST CURRENT EDITION OF THE MUNICIPALITY OF
ANCHORAGE STANDARD SPECIFICATIONS (MASS) FOR COMPONENT PARTS AND MATERIALS USED IN CONSTRUCTION OF
ON—SITE WASTEWATER DISPOSAL SYSTEMS AND THE ATTACHED SPECIFICATION.
3. SCOPE OF WORK: INSTALL NEW 2000g SEPTIC TANK AND SOIL ABSORPTION SYSTEM.
4. GROUNDWATER WAS NOT ENCOUNTERED AS EVIDENCED BY THE SOIL TEST HOLE. IF AN APPARENT WATER TABLE IS
OBSERVED IN ANY OF THE EXCAVATIONS LESS THAN 16.0 FEET BELOW EXISTING GRADE NOTIFY THE ENGINEER
IMMEDIATELY,
FILTER FABRIC
4' 0 DRAIN PIPE
TH_4 DRAIN ROCK 6;RHb0E-PIE INV
SW
ROCK
ML/
SM �-10.0 RESERVE SYSTEM SIMILAR
70 ONE TRENCH ONLY.
8.0
NO GROUND WATER
GM
MONITORED ON 10/17/13
16 w w
o _ F F m FILTER FABRIC m
Qo� z z wo 'oma 4"0 DRAIN PIPE �o
S6 � 61 z z z DRAIN ROCK z
0 u 0 o � � o V6" ABOVE PIPE INV o�
2000g SEPTIC
TANK
LEGEND
W WATERLINE/
WELL RADIUS
SS
NEW SEPTIC
DESIGN PARAMETERS
PRIMARY SEPTIC SYSTEM
NO. BEDROOM: 6 (900 gpd)
TANK SIZE: 2000g SEPTIC
PERC RATE = 1 MPI
SOIL RATING: 1.0 GPD/SF
AREA RQD: 900SF
SYS. TYPE: DEEP TRENCH 5'ED
MIN LENGTH: 90 LF
USE:
2EA 45LFx3'Wx5'EDx8.O'TD
TOTAL AREA: 900 SF
F.iT".T".TkoTayff.ivffo►Q
CU
COPPER
DIP
DUCTILE IRON PIPE
TH
TEST HOLE
FC
FOUNDATION CLEAN OUT
T#
TANK CLEAN OUT NO.
C#
CLEAN OUT NO.
M#
MONITOR TUBE NO.
R. 1.
RIGID INSULATION
DCO
DOUBLE CLEAN OUT
DV
DIVERTER VALVE
FS
FLOW SPLITTER
BFG
BELOW FINISH GRADE
OG
ORIGINAL GRADE
FG
FINISH GRADE
TS&V
TOPSOIL & VEGETATE
NOTES: .������\
PANNONE ENG SVC LLC Date
"�OF AG,q `l 5/28/2014
FOR CONSTRUCTION P.O. BOX 100217 ANCHORAGE, AK 99510
PHONE (907) 272-8218 FAX (907) 272-8211 ig�p �yf' Scale
jit:49T�� ,tl� NTS
VICKERY, LOT 1A ""' "' "' P.I.D. NO
E. HUFFMAN ROAD "S•te've'n 'R. anno017-441-51
ne PERMIT NO.
JOHN HAGMEIER I�' CE 8149 ... OSPI4XXXX
2204 CLEVELAND AVE #201 acs
DESIGN DETAILS ANCHORAGE, AK 99517 �'i` �``==`�' Sheet
eOF 4
4" JIM CAP
4" PUMP—OUT
SLIDE SECTION
OF 6" PIPE
OVER THIS CONNECTION
TO PROVIDE
SHEER PROTECTION—
EXTEND TO
BRIDGE EXCAVATION
ADVANTEX DESIGN
2 EACH.
ADVANTEX
AX20 POD\
24"
PASSIVE
INSULATED
AUXILIARY AIR
RISER,
PUMP VENT
BASIN
—GALLON
—GALLON 64'AN 3000
TAN 3000
DESIGN PARAMETERS
RESERVE SEPTIC SYSTEM
NO. BEDROOM: 6 (900 gpd)
TANK SIZE: 3000g SEPTIC
PERC RATE = 1 MPI
SOIL RATING: 5.0 GPD/SF
AREA ROD: 900SF
SYS. TYPE: DEEP TRENCH 5'ED
MIN LENGTH: 18 LF
USE:
45LFx3'Wx5'EDx8.0'TD
TOTAL AREA: 450 SF
NOTES: PAMONE ENG SVC, LLA.—�`pF At l Date
FOR CONSTRUCTION P.O. BOX 100217 ANCHORAGE, AK 99510 r (� • qs+<<� 5/za/zola
PHONE (907) 272-8218 FAX (907) 272-8211 TM �Y 00, ScaNTs
VICKERY, LOT 1A P.I.D. NO
E. HUFFMAN ROAD / on -441-51
JOHN HAGMEIER teveCE 894o�nnone% PERMIT NO.
' F"•• ,�- / OSP14XXXX
2204 CLEVELAND AVE #201 �) `r •. err
SITE SECTION ANCHORAGE, AK 99517 il`1Dy70S�p�p Sheet
3 OF 4
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
TEST HOLE
SOILS LOG - PERCOLATION TEST
SLOPE
ORGANICS
LOAMY SILTY
SAND
SAND
X
TI
SILT WITH
SOME SAND
SILTY GRAVEL
DATE PERFORMED: 1014/13
WAS GROUND WATER
ENCOUNTERED? N
IF YES. AT WHAT
DEPTH? -DRY'
DEPTH TO WATER AFTER
MONITORING? -DRY
DATE: 10/17/2013
I THi 1 F
TH-3
SLOPE
TH
X
READING DATE
CLOCK
WATERTIME NETTIME LEVEL NETDROP
READING
1 10/4/13
4:00
-- 5.50 —
2
4:02
2 MIN 11.50 -DRY 6.00
3
4
5
6
PEROLATION RATE <1 (min/inch) PERC HOLE DIAMETER 6 Inches
TEST RUN BETWEEN 5 FT AND 6 FT
COMMENTS: Test hole excavated by John Hagmeier Homes, LLC. Pere hole was presoaked.
Last 3 readings recorded.
PERFORMED BY: Steven R. Pannone. P.E. I CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE
WITH ALL STATE AND MUNICIPAL GUIDLINES IN EFFECT ON THE DATE OF THIS TEST.
NOTES:PANNONE ENG SVC, LLC r - of Vt Date
� ' o/,a/zo,s
P.O. BOX 100217 ANCHORAGE, AK 99510 ��P'' q.•�� j scale
PHONE (907) 272-8218 FAX (907) 272-8211 Gj.•' 9 ��
NTS
/ W:
VICKERY, LOT 1A '- P.I.D. NO
E. HUFFMAN ROAD "Ste'ven'R. Pannone' MIT 51
PERMIT N0.
JOHN HAGMEIER tjP . CE 5149 r OSPxxxxxX
2204 CLEVELAND AVE #201 ff��s sheet
SOILS LOG ANCHORAGE, AK 99517 (lo.ssto
4 OF 4
PLAT NO. 2014-23
VICKERY SUBDIVISION
LOT 1 A
49,775 S.F.
GASTALDI LAND
SURVEYING, LLC
JEFF A. GASTALDI, R.L.S.
2000 E. DOWLING RD., SUITE 8
ANCHORAGE, ALASKA 99507
PHONE 248-5454
I GRI SW2838 I D 12/30/20141
F.B.I JOB NO.
14-06 VS1A
BUILDING DETAIL
SCALE: 1"=20'
CCWC.
DECK
1 HEREBY CERTIFY THAT 1 HAVE SURVEYED THE
PROPERTY DEPICTED ABOVE AND THAT NO
ENCROACHMENTS EXIST EXCEPT AS INDICATED.
IT IS THE RESPONSIBILITY OF THE OWNER TO
DETERMINE THE EXISTENCE OF ANY EASEMENTS,
COVENANTS OR RESTRICTIONS WHICH DO NOT
APPEAR ON THE RECORDED SUBDIVISION PLAT.
UNDER NO CIRCUMSTANCES SHOULD ANY DATA
HEREON BE USED FOR CONSTRUCTION OR FOR
ESTABLISHING BOUNDARY OR FENCE LINES.
ANCHORAGE RECORDING DISTRICT, ALASKA
NOTE: NO CORNERS SET THIS DATE
1 11
=409
HUFFMAN
0
M
S 89°56'28"E
ROAD
164.84'
10' T. & E. ESMT.
i- -
I
I
- - - -
- - - - - - - - -
I
I
. ,
I
'
I
iV
I
SEPPC SYSTEM
M
I
I
FENCE (APX)
I
GRAWL DR.
c
'?
I
w
26.6•
M
W
W
Li
�ILpij
W
I
30.8'
n
,:I
o
�I
g
Z
I
I
z
I
I
KK
I
I
I
I
WELL
I
I
I
I
I- - -
- - - - - - -
- - - - - - - -
I
10' T. & E.
ESMT.
GASTALDI LAND
SURVEYING, LLC
JEFF A. GASTALDI, R.L.S.
2000 E. DOWLING RD., SUITE 8
ANCHORAGE, ALASKA 99507
PHONE 248-5454
I GRI SW2838 I D 12/30/20141
F.B.I JOB NO.
14-06 VS1A
BUILDING DETAIL
SCALE: 1"=20'
CCWC.
DECK
1 HEREBY CERTIFY THAT 1 HAVE SURVEYED THE
PROPERTY DEPICTED ABOVE AND THAT NO
ENCROACHMENTS EXIST EXCEPT AS INDICATED.
IT IS THE RESPONSIBILITY OF THE OWNER TO
DETERMINE THE EXISTENCE OF ANY EASEMENTS,
COVENANTS OR RESTRICTIONS WHICH DO NOT
APPEAR ON THE RECORDED SUBDIVISION PLAT.
UNDER NO CIRCUMSTANCES SHOULD ANY DATA
HEREON BE USED FOR CONSTRUCTION OR FOR
ESTABLISHING BOUNDARY OR FENCE LINES.
ANCHORAGE RECORDING DISTRICT, ALASKA
NOTE: NO CORNERS SET THIS DATE
1 11
=409
°f f i
• �� Municipality of Anchorages
On -Site Water and Wastewater Program
(907)343-7904
Certificate of On -Site Systems Approval
Parcel I.D. 017-441- 3 Expiration Date:
1. GENERAL INFORMATION
Complete legal description Vickery, Lot 1A
Location (site address) 6040 Huffman Rd.
Current Property owner(s) John Hagmeler
Mailing address
Real Estate Agent
Day phone
2204 Cleveland Ave. #201 Anchorage, AK 99517
2. TYPE OF DWELLING:
Fx1 Single Family (w/wo ADU)
❑ Duplex
❑ Multiple Dwellings (Single Family and/or Duplex)
3. NUMBER OF BEDROOMS: 6
Day phone
4. TYPE OF WATER SUPPLY:
TYPE OF WASTEWATER DISPOSAL:
Individual Well
0
Individual
El
Individual Water Storage
❑
Holding Tank
❑
Community Glass Well
❑
Community
❑
Public Water System
❑
Public Sewer
❑
WaiverNariance request for:
Received by: �«*/V w Date:
COSA to be released to the engineer, unless otherwise requested by the engineer.
COSA Fee $ 6" t 315 6b = BYI•�
Date of Payment
Receipt Number 6 (,n
COSA# D`�Ci� l bot
Waiver Fee $
Date of Payment
Receipt Number
Waiver #
5. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined
in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater
disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that
based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply
and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at
the time of installation.
In conducting an adequacy test, I attempt to provide a thorough, conscientious engineering analysis of the system in accordance with MoA COSA
guidelines and regulations. The reported results describe the performance of the system under the conditions encountered at the time of the test,
and separation distances measured to readily identifiable features. The operational life of all wells and septic systems depend on the local soil
condition, ground water levels that may fluctuate during the year, and the water usage of the family being served by the system. These conditions
are outside the control of the evaluator of this system. All systems eventually fail and satisfactory test results do not guarantee future
performance of the system, nor do they guarantee that there are no hidden defects or encroachments. Therefore we cannot provide any warranty
for future performance, nor can we estimate remaining life of the system. The content of this report is for the sole benefit of the owner listed
above.
Name of Firm Pannone Engineering Services LLC Phone (907) 272-8218
Address P.O. Box 100217, Anchorage Ak. 99510
Engineer's Printed Name Steven R Pannone
Date 1/7/2015
a
6. DSD SIGNATURE
System #1 Approved for bedrooms�Y" Siever V,*Pani
System #2 Approved for bedrooms �¢�c�' • CE -8149
Disapproved �$OFE551
Conditional approval for bedrooms, with the following stipulations:
T�-1�� r` RC_sU //c, 3 �f 3-
By: i G Original Certificate Date: I — a
VS—
The ni ipal ty of nchorage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only
,upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality
of Anchorage is not responsible for errors or omissions in the professional engineer's work. -
ATTACHMENTS:
COSA Checklist X Nitrate Advisory
Septic System Advisory Arsenic Advisory
Well Flow Advisory Other
COSA blue sheet f ., .
If more than 1 septic system is on the lot:
CASA Checklist.# iof
Structure served by this system 1
Certificate of On -Site Systems Approval Checklist
Legal Description
A. WELL DATA
Vickery, Lot 1A
Well type Private If A, B, or C provide PWSID #
Date completed 9/23/2014 Sanitary seal (Y/N) Y
Total depth 496 ft. Cased to 166 ft.
FROM WELL LOG
Date of test 9/23/2014
Static water level 175
Well production 3.2
ft.
9_13 M.
WATER SAMPLE RESULTS:
Coliform colonies/100 mL Nitrate R2fng/L
Arsenic ug/L Date of sample r C1 - /
B. SEPTICIHOLDING TANK DATA
Tank Type/Material Septic/Steel
Tank size 2,000 gal. Number of Compartments 2
Foundation cleanout (Y/N) Y
Date of pumping New
Depression over tank (Y/N) N
Pumper
Parcel ID: 017-441-83
Well Log (Y/N) Y
Wires properly protected (Y/N) Y
Casing height (above ground) 18+ in.
AT INSPECTION
New
New
New
ft.
Collected by: Cam avie_ F,
Date installed 11/12/2014
Cleanouts (Y/N) Y
High water alarm (Y/N) N
C. ABSORPTION FIELD DATA
Date installed 11113/2014 Soil rating (g.p.d./ftz or ftz/bdrm) 1 GPD/SF System type Deep Trench
Length 90 ft. Width 3 ft. Gravel below pipe 5 ft.
Total depth 8 ft. Eff. absorption area 900 ftz Monitoring tube Y Depression over field N
Date of adequacy test New Results (Pass/Fail) PASS For 6 bedrooms
Fluid depth in absorption field before test New in. Water added New gal. New depth New in.
Elapsed Time: New min. Final fluid depth New in. Absorption rate >= 900+ g.p.d.
Any rejuvenation treatment (past 12 mo.) (Y/N & type) No If yes, give date _
D. LIFT STATION
Date installed
"Pump on" level at in
Datum
E. SEPARATION DISTANCES
WELL ON LOT TO:
Size in gallons _
"Pump off" level at
Cycles tested
Septic tank/lift station on lot 100+
Absorption field on lot 100+
Public sewer main 75+
Sewer /septic service line 25+
Animal containment areas 50+
Manhole/Access (Y/N) _
in. High water alarm level at
Meets alarm & circuit requirements?
On adjacent lots 100+
On adjacent lots 100+
Public sewer manhole/cleanout 100+
Holding tank 100+
Manure/animal excrete storage areas 100+
SEPTIC/HOLDING TANK ON LOT TO:
Building foundation 5+ Property line 5+
Water main 10+ Water service line 10+
Wells on adjacent lots 100+
ABSORPTION FIELD ON LOT TO:
Property line 10+ Building foundation 10+
Water Service line 10+ Surface water 100+
Curtain drain 50+ Wells on adjacent lots 100+
F. COMMENTS
G. ENGINEER'S CERTIFICATION
l certify that l have determined through field inspections and
review of Municipal records that the above systems are in
conformance with MOA COSA guidelines in effect on this date.
Engineer's Printed Name Steven R. Pannone
Date 1/7/2015
COSA brown sheet 10-10-12.doc
Absorption field 5+
Surface water 100+
Water main 10+
Driveway, parking/vehicle storage 110+
in.
Municipality of Anchorage
Community Development Department
Development Services Division
On -Site Water and Wastewater Program
4700 Elmore Street
P.O. Box 196650 Anchorage, AK 99519-6650
www.muni.org/onsite
(907)343-7904
Nitrate Advisory
Certificate of On -Site Systems Approval # 151002
A Certificate of On -Site Systems Approval inspection and test of potable
water was recently conducted on the well water supply on Block , Lot
IA of Vickery subdivision. This inspection revealed a nitrate concentration
of 5.82 milligrams per liter (mg/L) was reported for the property's well
water sample. The Environmental Protection Agency (EPA) has established
a maximum contaminant level (MCL) of 10.0 mg/L for public drinking
water systems. While private wells are not subject to this regulation, EPA
standards are based on existing health information and can therefore be used
to gauge the relative quality of water from private wells. Please see the
attached "Nitrate Fact Sheet" for important information regarding nitrate.
This advisory must be attached to all copies of the subject Certificate of On -
Site Systems Approval.
SGS Ref.#
1150098001
Client Name
Pannone Eng. Stv.
Project Name/W
Vickery, Lot 1
Client Sample ID
Vickery, Lot 1
A4atrix
Drinking Water
Sample Remarks:
Nitrate was analyzed by Analytica of Anchorage, AK.
Printed Date/Time
Collected Date/Time
Received Daterrime
Technical Director
01/15/2015 14:08
01/09/2015 14:15
01/09/2015 14:32
Stephen C. Ede
Allowable Prep Analysis
Parameter Results LOQ Units Method Container ID Limits Date Date Init
Metals by ICP/MS
Arsenic
ND
5.00 UG/L
EP200.8
Microbiology Laboratory
E. Coti
Negative
1 100mL
SM21 9223B
Total Coliform
Negative
I 100mL
SM21 9223E
C (<10) 01/12/15 01/14/15 ACE
A 01/09/15 MEV
A 01/09/15 MEV