Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
DEARMOUN #2 BLK 2 LT 5
I)eArmoun #2 Block 2 Lot 5 #018-401-34 Inspection Report _1-1-12.doc Municipality of Anchorage Community Development Department Page 1 of 3 On-Site Water & Wastewater Program 4700 Elmore St. • P.O. Box 196650 Anchorage, AK 99519-6650 • http://www.muni.org/onsite e (907)343-7904 ON-SITE WASTEWATER INSPECTION REPORT Permit Number: OSP151039 PID Number: 018-401-34 ❑ New N Upgrade Name: RUSSELL OAKELEY ABSORPTION FIELD ® Deep Trench ❑ Shallow Trench ❑ Bed ❑ Mound Address: 3700 MATTHEWS DRIVE, ANCHORAGE, AK, 99516 ❑ Other Phone: No. of Bedrooms: Soil Rating: Total Depth from or;g;not grade: (907) 903-6629 4 1.0 GPD/Sq. Ft. 8.5 MAX Ft. LEGAL DESCRIPTION Depth to pipe invert from original grade: Gravel depth beneolh pipe: SEE DWG. Ft. 6.0/6.0 n. Subdivision: Block: Lot: Pill added above original grade: Gravel length: DEARMOUN #2 2 5 SEE DWG. 25/25 Ft. Ft. Township: Range: Section: Gravel width: Beds Number of lines: Distance between lines: — — — 2.5/2.5 Ft. I — Ft. SEPARATIONDISTANCES Total absorption area: 600 Number of trenches: 2 Dist. between trenches: 1 2 TO Septic Absorption Lift Holding Public/Private From Tank Field Station Tank Sewer Lines So.Ft. R, Well — — — — 25'+ TANK ❑ Septic ® S.T.E.P. ElHolding ❑ Other Manufacturer: Copac;ty: Surface Water 100'+ 100'+ 100'+ — ANCHORAGE TANK 1500 cal. Lot Line 5'+ 10'+ , o'+ - N/A Material: Number of compartments: STEEL 2 LIFT STATION Foundation 5'+ 10'+ 10'+ — Curtain Drain NONE KNOWN Manufacturer. Capacity: ANCHORAGE TANK/ORENCO 1500 cal. 'Pump on- level at: "Pump off' level at: High water alarm at: Remarks: 42 42 46 OLD TANK WAS ABANDONED PER UPC Pump Make & Model: DRENCO PF-30 Electrical Inspections performed by: M.O.A. PIPE MATERIAL House to tank D3034 Tank to D2665 droinfield Installer Drainfield D3034 CO/MT D3034 WILCO CONTRACTORS Inspector GEG, Ltd. BENCH MARK (Assumed elevation) 1 DO. 00 Ft. Inspection Location and DescYption: Dates: 1st 3/2/2015 2nd 3/2/2015 BOTTOM OF VERTICAL TRIM, NW CORNER OF 3rd 3/2/2015 4th — FIREPLACE CHASE, WEST WALL. ENGINEER'S SEAL Community Development Department Approval 9a�oo of ®� ........... gS00 Conditional approval: Date: 9T......��QOO ...:.................� QOO� Je e A. Ga ness: Q E 95 / 3'J� -/ �&4_'-1 f�4d Approved: Date: protes slon`°oF°ad �OO000�6 Inspection Report _1-1-12.doc OSP151039 AS -BUILT DRAWING PARCEL ID NUMBER 018-401-34 T'= 20' NEW DRAINFIELDS C�;/ C01 MT1 MT:2 I I I I I I I I I I I I I I I FS I I I I I I I GEG I I TH#1 I I I C04 MT4 MT3 19 Cf B NEW 1500 GALLON S.T.E.P. TANK MATTHEWS DRIVE KEYBOX ° I DRIVEWAY I. 1 m. - ` I I. EXISTING 4 BEDROOM HOUSE - FCO VERIFIED DURING CONSTRUCTION OLD TANK WAS ABANDONED IN PLACE PER UPC __________________7 /r O NOTE: 1972 CRIB r I � O OLD / LOCATION BASED --------------------------------CRIB UPON 2001 K.N.D. EXISTING TRENCH WAS CONNECTED _ i ENGINEERING DESIGN AS RESERVE SITE GARNESS ENGINEERING A B C ST1 - 11.57 36.73 ST2 - 16.08 44.61 MH - 17.41 46.30 C01 14.27 36.81 - MTI 14.85 36.98 - 0O2 29.25 44.75 - MT2 30.18 43.28 - FS 21.95 30.51 - 0O3 23.99 15.13 - MT324.23 16.45 - C04 34.33 28.93 - MT4 35.49 30.58 - T'= 20' NEW DRAINFIELDS C�;/ C01 MT1 MT:2 I I I I I I I I I I I I I I I FS I I I I I I I GEG I I TH#1 I I I C04 MT4 MT3 19 Cf B NEW 1500 GALLON S.T.E.P. TANK MATTHEWS DRIVE KEYBOX ° I DRIVEWAY I. 1 m. - ` I I. EXISTING 4 BEDROOM HOUSE - FCO VERIFIED DURING CONSTRUCTION OLD TANK WAS ABANDONED IN PLACE PER UPC __________________7 /r O NOTE: 1972 CRIB r I � O OLD / LOCATION BASED --------------------------------CRIB UPON 2001 K.N.D. EXISTING TRENCH WAS CONNECTED _ i ENGINEERING DESIGN AS RESERVE SITE GARNESS ENGINEERING GROUP, Ltd CIVIL & ENVIRONMENTAL ENGINEERS V EY E.NOOR ROAD. SUITE 101'P OR E.M NSW -PHONE (NO 3N)8178' FAC (MY)3384NO- WE83RE:xwn'.gameasmgnexn, 'REPARED FOR: PHONENUMBER: PAGE NUMBER: RUSSELL OAKELEY (907) 903-6629 2 OF 3 .EGAL DESCRIPTION: DRAWN SY: DEARMOUN S/D #2; BLOCK 2, LOT 5 A.J.G. -YPE OF WORK: DATE: , AS -BUILT DRAWING OF SEPTIC UPGRADE 3/6/2015 A. i PERMIOSP 151039 T NUMBER AS -BUILT D RAW I N G /Ir FINAL GRADE - 99.21-99.65 ST1 ( ST2 MH TOP OF TANK j TOP OFT AT INLET=94.74 � /- AT OUTLET m 9494.65 INVERT OF BUNG AT INLET =94.55 WEST TRENCH NEW 1500 GALLON S.T.E.P. TANK FINAL GRADE GEG =99.01-99.16 TH#1 7CT' INSULATION , FILTER FABRIC INVERT OF PIPE = 96.67 121+ - BOTTOM OF TRENCH = 90.67 EAST TRENCH PARCEL ID NUMBER: 018-401-34 FINAL GRADE 99.56-99.62 2' INSULATION FILTER FABRIC INVERT OF PIPE _ 96.67 - BOTTOM OF TRENCH =90.67 RELATIVE ELEVATION OF BOTTOM OF TESTHOLE = 84.67 (DRY) GARNESS ENGINEERING GROUP, Ltd .....::..... ............. •.. CIVIL & ENVIRONMENTAL ENGINEERS66r - mm« mm • 3]01E.TUWR WAD. SUIM 101'AWHORM'E,AK985N'PIpNE IBQ1133]61]8'FP%19M133B324B'WEBSITE: xvrv•pame¢emgree�pp.com �• • • •• •• ••••• ••i •5 •• ,1 ff ey A. Gafness PREPARED FOR: PHONE NUMBER: PAGE NUMBER: RUSSEL OAKELEY ( 907) 903-6629 3 OF 3 ♦j�% CE -7953 ♦ ST •'', ♦♦ F� '., ID' ♦ Fp 'p(.......(•T� ♦'�,'' 1L7FESS\ lak was LEGAL DESCRIPTION: DEARMOUN S/D #2; BLOCK 2, LOT 5 DRAWN BY: A.J.G. TYPE OF WORK: PROFILE AS -BUILT OF SEPTIC UPGRADE DATE: 3/6/2015 2/ - � \ - On -Site Wastewater Disposal System Permit MUNICIPALITY OF ANCHORAGE Development Services Department On -Site Water & Wastewater Program 4700 Elmore Road, PO Box 196650 Anchorage, AK 99519-6650 Telephone: (907) 343-7904 Permit Number: OSP151039 Tax Code Number: 01840134000 Work Type: Septic Upgrade Permit Effective Dates: February 20, 2015 to February 20, 2016 Design Engineer: GARNESS ENGINEERING GROUP LTD Subdivision: DEARMOUN #2 Site Legal Address: DEARMOUN #2 BLK 2 LT 5 G:2935 Owner/Address: OAKELEY RUSSELL J & ROMERO-OAKELEY KAREN 3700 MATTHEWS DRIVE ANCHORAGE AK 995163525 Site Mailing Address: 3700 MATTHEWS DR, Anchorage Lot Size in Sq Ft: 13139 Total Bedrooms: 4 This permit is for the construction of: Y Disposal Field Y Septic Tank N Holding Tank N Privy N Private Well N Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80). 3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either: A. Open and Close on the same day. B. Covered, sealed, and heated to prevent freezing. Received Issued By rtv oPVet,'xA)t &'0aj�e Municipality of Anchorage Deveionment Services Division Onsite Water and Wastewater Program rnent,S, 1p 0 pa' G n y apartment **** VARIANCE/WAIVER REVIEW **** Waiver#: OSV151002 COSA#: _ Permit#: OSPI61039 PID#: 018-401-34 Legal Description: Dearmoun #2. Block 2.. Lot 5 Engineer: Garness Ennineerina Group Applicant: RusselOakel Your request for a waiver of the required 10 feet horizontal separation from the absorption field to the propertyline has been approved. The approved separation distance is 5.0 feet. This waiver approval applies to the proposed absorption field only. Any future upgrade to the on-site wastewater disposal' system will require all separation distances be met or another approval from this department. ❑ The affected adjacent property owner(s) have been given a 7 day notice regarding this waiver. Notarized letter(s) _ of non -objection have been received from the owner(s) of the affected adjacent property, ED Adjacent properties are not affected by this waiver. ..............: .............. men ...... :...................-....... WOMEN .... ..... Waiver is Granted: X Waiver is not Granted: Date: o? a Approved by: e of Reviewer .......::. ..................... ■......:....N...... ..........sO.................. MUNICIPALITY OF ANCHORAGE,r Community Development Department Phone: 907-343-7904 Development Services Fax: 907- 343-7997 On -Site Water & Wastewater Program Mayor Dan Sullivan On -Site Sewer/Well Permit Application For A Single Family Dwelling Parcel I.D. 018-401-34 Property owner(s) RUSSEL OAKELEY Mailing address 3700 MATTHEWS DRIVE, ANCHORAGE, AK 99516 Day phone Site address 3700 MATTHEWS DRIVE, ANCHORAGE, AK, 99516 Legal description (Sub'd, Block & Lot) DEARMOUN S/D #2: BLOCK 2 LOT 5 Legal description (Township, Section & Range) Lot Size Sq. Ft. Number of Bedrooms 4 APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DEWELLING: (Rall that apply) Initial ❑ Single Family (SF) Absorption Field ® Upgrade ® (w/wo ADU) Septic Tank ® Renewal Duplex (D) F-1❑ Holding Tank F-1 MultipleDwellings ❑ Privy ❑ (SF and/or D) Private Well ❑ Water Storage ❑ THIS APPLICATION INCLUDES A VARIANCE/ WAIVER REQUEST FOR: DRAINFIELD TO LOT LINE Distance: 5+ FEET I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal codes. GARNESS ENGINEERING GROUP, Ltd. (Signature of property owner or authorized agent) D"sh 4Ash Permit/Rush Fees: '50' 4-.y0 ---9-10.4' Waiver Fees: 2115 'l 1'-L'9 ' =3 yy - Date of Payment: 2.1 ZO/l5 Date of Payment: aI415- Receipt Number: 0S531 G Receipt Number: 6a31(p G Permit No. 05P /-5' /0 36 Waiver No.: 6SV l5/06i- (Rev. 01/11) GARNESS ENGINEERING GROUP, Ltd CIVIL & ENVIRONMENTAL ENGINEERS February 19, 2015 Municipality of Anchorage Development Service Department On -Site Water & Wastewater Program 4700 Elmore Road, Anchorage, Ak 99519-6650 (907)343-7904 Proposed Septic Upgrade for DeArmoun S/D #2; Block 2, Lot 5. To whom it may concern, The subject property is served by a community well and a private septic system consisting of a 1000 gallon septic system and a trench type drainfield. The septic system is in a state of failure and needs to be upgraded. Per the owner's request, we are proposing to install a 4 bedroom septic system consisting of a 1500 gallon STEP tank and a dual trench type drainfield. Design comments are summarized as follows: SOIL CONDITIONS: See the attached soil log and sieve analysis which shows the soil classification, groundwater monitoring, and the percolation test results. A sieve analysis was performed on the soil and was found to be an SM, Silty Sand w/ Gravel. Although the soil perked at a rate of less than 1 minute per inch, we believe the insitu SM soils will negate the need for a sand filter. SURFACE WATERS: There are no surface waters within 100 feet of the proposed septic upgrade. TOPOGRAPHY: The topography in the area of the proposed upgrade is relatively flat. In short, there are no slope concerns. LOT LINE WAIVER REQUEST: Due to site constraints, we are requesting that you waive the distance from drainfield to the west lot line to 5 feet. The lot line is adjacent to the roadway and therefore poses no encroachment concerns. I am unaware of any adverse impacts this installation would have on any surrounding wells or septic systems. If you ha�p any questions, please contact us at 337-6179. M.S. 3701 East Tudor Road, Suite 101 * Anchorage, Alaska 99507.1259 Phone: (907) 337-6179 * Fax: (907) 338-3246 * Website: www.garnessengineering.com I I I I II I 14 I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I --- --- -------- 41 --- I ---------- --- I ----- DEARMOUN #2; BLOCK 1. LOT . I I I I DEARMOUN #2; BLOCK 1, LOT 4 DEARMOUN #2; BLOCK 1, LOT 3 DEARMOUN #2; BLOCK 1, LOT 2 DEARMOUN #2; BLOCK 1, LOT 1 HOUSE DEARMOUN #2-/ BLOCK 2, LOT A r � r I I zoos DEARMOUNI #2; BLOCK 2, LIDT 3 I � I BLOCK 2U LOT�. o �I �I WI JL IU DEAR jAOGN #2; LOCK 2. LOT 6 ------ ------ ---- \DEARMOUN #2; #2; DEARMOUN #2; DEARMOUN #2;BLOCK 1 A LLII 1, LOT 6JDEARMOUN BLOCK 1, LOT 7 BLOCK 1, LDT B BLOCK 1, LOT 9 ' I I DEARMOUN #2; BLOCK 1. LOT . I I I I DEARMOUN #2; BLOCK 1, LOT 4 DEARMOUN #2; BLOCK 1, LOT 3 DEARMOUN #2; BLOCK 1, LOT 2 DEARMOUN #2; BLOCK 1, LOT 1 HOUSE DEARMOUN #2-/ BLOCK 2, LOT A r � r I I zoos DEARMOUNI #2; BLOCK 2, LIDT 3 I � I BLOCK 2U LOT�. o �I �I WI JL IU DEAR jAOGN #2; LOCK 2. LOT 6 I \ \ LLII DEARMOUN #2; BLOCK 2, LOT 7 m ' I I V' I "A" WELL EXISTING CLASS 'A' COMMUNITY WELL BLOCKM 2U LOT2 8 / V\ / SEPTIC \ / AREA DEARMOUN #2; i BLOCK 2, LOT i _ I I ------J L------ ------------ GARNESS ENGINEERING GROUP, Ltd CIVIL & ENVIRONMENTAL ENGINEERS 3701 E. TUDOR 6090, SUITE 101 " MCH E, 9W 995M • PNONE (907) 337-6179 • FAC (907) 336-3246 " WEBSITE: Mrvqu Wn ih An9.com 3REPARED FOR: PHONE NUMBER: PAGE NUMBER: RUSSELL OAKELEY 903-6629 1 OF 2 AL DESCRIPTION: DRAWN BY: DEARMOUN #2; BLOCK 2, LOT 5 PNB E OF WORK: DATE: SITE PLAN 2/18/2 5 >f NUMBER OF BEDROOMS: 4 GALLONS PER DAY (GPD): 600 PERCOLATION RATES: �l MINJINCH PROPOSED APPLICATION RATE: 1.0 GPD/FT' MINIMUM DRAINFIELD SO.FT.: 600 MAXIMUM DEPTH: 8.5 FEET WIDTH: 2.5 FEET LENGTH: 50 TOTAL (2 @ 25)FEET M.O.A. APPROVED SAND FILTER: N/A EFFECTIVE: 6 FEET REDUCTION FACTOR: N/A ACTUAL SQ.FT.: 600 PROPOSED DRAINFIELDS GEG, Ltd. HAS AN 8 PAGE SPECIFICATION LETTER THAT PERTAINS TO THIS DESIGN. TO OBTAIN A COPY OF THE LETTER CONTACT GEG. BY PROCEEDING FORWARD WITH THIS INSTALLATION, THE ENGINEER, WELL DRILLER, CONTRACTOR AND PROPERTY OWNER AGREE THAT THEY HAVE READ THESE SPECIFICATIONS AND AGREE TO ACCEPT THE TERMS AND CONDITIONS OUTLINED. ((�������� PROPOSED FLOW LITTEC�� �PRT TO 4"GR GRAVITY ED) < 4"GRAVITY FEED) -�- GEG TH#1 p, C NUMBER OF BEDROOMS: 4 GALLONS PER DAY (GPD): 600 PERCOLATION RATES: �l MINAINCH PROPOSED APPLICATION RATE: 4.0 GPD/FT' MINIMUM DRAINFIELD SQ.FT.: 125 CATEGORY It ADVANCED TREATMENT MINIMUM MAXIMUM DEPTH: 8.5 FEET WIDTH: 2.5 FEET LENGTH: 25 FEET M.O.A. APPROVED SAND FILTER: NIA EFFECTIVE: 6 FEET REDUCTION FACTOR: N/A ACTUAL SQ.FT.: 300 KEYBOX dZNa PREPARED FOR: d PAGE NUMBER: }a' d I 2 OF 2 LEGAL DESCRIPTION: DRIVEWAY JI A.J.G. 4'11 Iw � DESIGN DRAWING OF PROPOSED SEPTIC UPGRADE 13 . d I' a�I. EXISTING 4 BEDROOM HOUSE L----- ---------------- iVERIFYORINSTALL RESERVE SITEwil FOUNDATION CLEANOUT �. EXISTING SEPTIC TANK TO BE ABANDONED PER UPC PROPOSED 1500 GALLON STEP TANK O i _______ ------------------T ) NOTE: 1972 CRIB 1 (- o OLD LOCATION BASED '----------------- _ CRIB ______ - I -� / UPON 2001 K.N.D. EXISTING TRENCH TO BE CONNECTED - ENGINEERING DESIGN AS RESERVE SITE GARNESS ENGINEERING GROUP, Ltd CIVIL & ENVIRONMENTAL ENGINEERS 3]Ul E.TUWRROA0.3UNE 101`ANCHOP E.AK9 07'PHONE(N7)33 170'FMM7)33 M6'WE88ITE:x pemeeeen&ema6� PREPARED FOR: PHONE NUMBER: PAGE NUMBER: RUSSELL OAKELEY (907) 903-6629 2 OF 2 LEGAL DESCRIPTION: DRAWN BY: DEARMOUN S/D #2; BLOCK 2, LOT 5 A.J.G. TYPE OF WORK: DATE: � DESIGN DRAWING OF PROPOSED SEPTIC UPGRADE 2/18/2015 �OFESS�� i GARNESS ENGINEERING GROUP, Ltd 1 CIVIL & ENVIRONMENTAL ENGINEERS 3701 E •. TUWR ROAD, SUITE IDI' AWH0R40E. AN 00 -PHONE HGOO Wi 179 -FA OEM 3383246' WEBSITE wxw.gameacanOHean,q.wm SOIL LOG - PERCOLATION TEST LEGAL DESCRIPTION: DEARMOUN S/D #2; BLOCK 2, LOT 5 PERFORMED FOR: RUSSEL OAKELEY DATE. 2/12/2015 DEPTH ( feep ORGANICS E 7 E 9 10 11 12 13 14 15 16 17 18 SM SILTY SAND W/GRAVEL TEST HOLE #1 SOIL CLASSIFICATIONS DEPTH TO GROUNDWATER DATE DRY 2/12/2015 !m�jmjjjjmjjjj 2/19/2015 l!11 %//0 %% NNN • I IIIIIIIII � • %////. 111111 �'.z.� • F DEPTH TO GROUNDWATER DATE DRY 2/12/2015 DRY 2/19/2015 SI DATE READING CLOCK (MINUTI S) WATER READING EL N NET HRS) 2/12/2015 I IPERK HOLE ABSORBED 10 GALLONS OF WATER AS FAST AS ADDED I I 19 PERCOLATION RATE <1 (MIN./INCH) PERC. HOLE DIA. 6 (INCHES) TEST RUN BETWEEN 5.0 FT. AND 6.0 FT. 20 A FOUR HOUR PRESOAK WAS PERFORMED: ❑ YES ENO SOILS LOGGED BY: ANDREW GRAY PERCOLATION TEST PERFORMED BY: ANDREW GRAY COMMENTS: PERCOLATION READINGS ARE WITHIN 1/16 OF INCH. PERFORMED BY GEG, Ltd. I, JEFFREY A. GARNESS, CERTIFY THAT THIS WAS PERF RIME IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE: /�� L p LO Lo O O O N Y T `d V Z Q. CL L p Y A N m - 'g `o o L AM t � N: f+� N � a � � � � # #it ik i! •lC � OC oc c c c c N 0 0 > 8 CD 0 •Yj V 'J L C R M d V1 2 0 R d ,5 O W W U w W CO U) rn M M co O Of W LL O T O O N O N O � n 0 rn Cl) O m T O) O � O Y N Q E O O L 4) Q CA • N t T � m fi 0 v W a C C O Q T Y w O O m T m m O COO COO M N O d U T c .. o 4y619M Aq 6UISSOd ;UaaJad W LL Municipality of Anchorage Development Services Department Building Safety Division On-Site Water and Wastewater Program, 4700 S. Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 Page of www.ci.anchorage.ak.us (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT Permit Number: SWO10142 PID Number: 018.401-34 Name: Wastewater System: ❑ New ® Upgrade William E. Johnson Address: 3700 Mathews Drive Anchora a AK 99516 ABSORPTION FIELD Phone: Number of Bedrooms: 344-7922 3 O Deep Trench ® Shallow Trench ❑ Bed ❑ Mound 0 Other: LEGAL DESCRIPTION Soil Rating: 0.8 Total Depth from original grade: GPD/Fe 8.03 Ft. Block: Lot: Subdivision: Depth to pipe bottom from original grade: Gravel depth beneath pipe: 2 5 DeArmotin #2 3.94 Ft. 4.09 FL Township: Range: Section: Fill added above original grade: Gravel Length: 0.9 Ft. 41 Ft. Well: ❑ New ElUpgrade Gravel width: Number of lines: Distance between lines: 5 Ft. 1 NA FL Classification (Private, A. B, C): Total Depth:Cased to: Total absorption area: Pipe Materiel: A Ft. FL 410 FIT D3034 & F810 Driller. Date Drilled: Static Water Level: Installer. Date Installed: Ft. Book's Contractin 5131101 Yield: Pump Set at: Casing Height Above Gmund: TANK GPM FL Ft. SEPARATION DISTANCES ® Septic ❑ Holding ❑ S.T.E.P. ❑ Other: To Septic Absorption Lift Holding Public/Privat Manufacturer: Capacity: From Tank Field Station Tank Sewer Line Greer 1000 Gal. Well 200'+ 2U0'+ NA NA 25'+ Material: Steel Number of Compartments: 2 serf.a.Water 100'+ 100'+ NA NA LIFT STATION Lot Line 5'+ 3' NA NA Size: Manufacturer: Gal. 5'+ 10'+ NA NA 'Pump Or, level at: 'Pump off" level at: High water alarm at: Foundation in. In. In. Curtain Drain NA *50'+ NA NA Pump Make B Model Electrical Inspections performed by: Remarks: *none known BENCH MARK Location and Description: 1)+ut rev k e i ew. j$ Top of porch LASSUrned ItoT f-safntciG(. 'i'n S S 4G�,., alk Lievation: 100 Ft. Enginee Stamp �P�E OF gtq�li AW ~ �� Inspections performed by: KND Engineering Dates: tat 5/3112001•9.L•.••.• ........ 2nd 5/31/2001 ....,•,,, ., .,tc� Development Services Department Approvalm'• Kenneth M. Guff, W / Reviewed by: Date: "0 CE 7116 4�TFq'v,,,.�•••••,.••� 'AV and approved (9' Rev_ tsroo) � ��a OF EsS10�P�e� *trema_ ND ENGINEERING 20441 PTARMIGAN BLVD. EAGLE RIVER, AK 99577-8736 (907)696-5111 May 31, 2001 Municipality of Anchorage Development Services Department On -Site Water & Wastewater Program P.O. Box 196650 Anchorage, AK 99519-6650 RE: LOT LINE WAIVER — DeArmoun #2, B2, L5 Gentlemen: Due to the limited area for the septic system upgrade, we had to build the trench within 10 feet of property. The system is still located within the testhole radius and we do not expect there to be any adverse effect on adjacent lots by the location of this system. We are therefore requesting a waiver to 3.0 feet to lot line at this time. If you have any questions, please contact me at 696-6111/FAX 696-8111. Respectfully submitted, KND Engineering enneth M. Duffus, P.E. Attachments: As -built Inspection Report HAA AS -BUILT SYSTEM DETAILS/SITE PLAN Permit SWO10142 DEARMOUN #2, BLOCK 2, LOT 5 PID# 018-401-34 F ---------------------------------------------- i KND i i 5 I I I EXISTING 3 s FP GMT BORM HOUSE A M � I 1000 GAL C SEPTIC T JK EXISTING I O SEPTIC C.O. I C0 I MT E CO MT PRIMARY IELD FENCE, I I I.. I I SEPTI , I 1 _ L_L_I I i I I I 98.16 97.8 W A—C= 11.0' B—C= 27.0' N A—D=15.7' a a a dd d: ORIGINAL GRADE B—D= 28.2' 97.18 WNW A—E=33.2' E9FagIC — B—E= 45.7' 4 1000 GAL A—F=50.2' SEPTIC 925.7777 B—F= 77.6' TANK SEWER ROCK F A 4\ �� .......................`9S ,4 TH* _v - 7 * KENNETH DF E-7116 � '•w'E33IO'O Aw PREPARED FOR: BILL JOHNSON 3700 MATHEWS ANCHORAGE, AK (907) 344-7922 FIELD BOOKS COMPGTED: BWNDARY: LAN MARK OBAMH' VBG STAwNQ LANMARK a CXEm KMD ASBOaT' LANMARK DAX' 5/31 °MO "LE 01M 2935 ACAO FILE: 01027.DWG 'OB No.: 01027 41' 109 I I.... s SEPTIC ... SEPTIC I I ��_"qFPTI SCA E. 1' = 50' ff"a 97.4 nn °PM MIFF 92.59: T SCALE: NTS 822 M>x IL\�IV U) ENGINEERING 20441 PTARMIGAN BLVD EAGLE RIVER, AK 99577-8736 (907)696-6111/FAX (907)696-8111 Municipality of Anchorage George P. Wuerch, Mayor Building Safety Division P.O. Box 196650 • 4700 S. Bragaw Street Anchorage, Alaska 99519-6650 • (907) 343-8301 http://N ww.ei.anchoiuge.ak.us KND Engineering ATTN: Kenneth M. Duffus, PE 20441 Ptamigan Blvd. Eagle River, AK 99577 - June 04, 2001 Subject: Waiver Request forDEARMOUN 92 BLK 2 LT 5 Waiver # WRO10031 Lot Line Request for Parcel ID 018-401-34 Dear Engineer: Department of Public Works Your request for a waiver of the required 10 feet horizontal separation of the on-site wastewater disposal system to the lot line has been approved. The approved separation distance is 3 feet. This waiver approval applies to the current on-site wastewater disposal system and lot line separation only. Any future upgrade to the on-site wastewater disposal system and lot line will require all separation distances to be met or another waiver approval from this department. If there are any further concerns or questions regarding this waiver, please call our office at 343-4744. Sincerely, Jeff Poet Engineering Technician III On -Site Water Quality Program MUNICIPALITY OF ANCHORAGE Department of Health & Human Services On -Site Services Waiver Review Worksheet WR#: 010031 PID#: 01840134 HA#: 010260 Permit#: Date Received: 060101 Legal Description: DEARMOUN #2 BILK 2 LOT 5 Engineer: Kenneth Duffus 20441 Ptarmigan Blvd. Eagle River. Ak. 99577 Applicant: William E. iohnson Waiver Requested: Absorption field to lot line of 3 feet. Criteria: 1. Geology Points: A. Water Table B. Soil Sorption C. Permeability D. Water Table Gradient E. Horizontal Separation 2. Special Conditions: 3. Other: Waiver is Granted: List Conditions or Reasons for above: Date: - 7 ' 0 i By: Rec#: 060101 Amount: 115 Date Paid: 060101 Total: Waiver is not Granted: MUNICIPALITY OF ANCHORAGE Development Services Department On -Site Wafer & Wastewater Program 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT Upgrade Date Issued: May 30, 2001 Expiration Date: May 30, 2002 Permit Number: SWO10142 Parcel ID: 018-401-34 Legal Description: DEARMOUN #2 BLK 2 LT 5 Design Engineer: 0070 KND Engineering Site Address: 003700 MATTHEWS DR Owner Name: WILLIAM E. JOHNSON Lot Size: 13139 SQ. FT. Owner Address: 3700 MATTHEWS DRIVE Total Bedrooms: 3 Permit Bedrooms: 3 ANCHORAGE , AK 99516-3525 This permit is for the construction of: ✓I Disposal Field U Septic Tank ] Holding Tank _ Privy ❑ Private Well J Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ). 3, The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. Received By: Issued By: Date: S 30 6 Date: .- — 3O -O/ Municipality of Anchorage Development Services Department Building Safety Division On -Site Water and Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907) 343-7904 ON-SITE SEWER/WELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Parcell.D. 611,, -Llol -- _3Vf Permit NumberSWO/0/¢2 Property owner(s) Day phone Mailing address (1)7/-'C�%D� =3 Mailing address (2) / Zip Code 99S/4 -3SLs Legal description (Lot, Block & Sub'd. 61 15 / ' - fYL©�c yr Legal description (Section, Township & Range) Lot Size f— Acres/(!q.F Number of Bedrooms 13"/39 THIS APPLICATION IS FOR: Sewer Only ❑ Well Only ❑ Sewer and Well ❑ Water Storage ❑ Sewer Upgrade R THIS PROPERTY CONTAINS: Hot Tub ❑ Jacuzzi ❑ Swimming Pool ❑ Water Softening Unit ❑ Therapy Pool ❑ I certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal Codes. (Signature of property,d)k#r or authorized agent) Permit Fees: Z) -o Waiver Fees: Date of Payment: ll .�/ D / Date of Payment: Receipt Number: `r(p 5-Y- Receipt Number: (Rev. 12/00) KHD ENGINEERING 20441 PTARMIGAN BLVD. EAGLE RIVER, AK 99577-8736 (907)696-6111/FAX (907)696-8111 May 16, 2001 Municipality of Anchorage Development Services Department On -Site Water & Wastewater Program P.O. Box 196650 Anchorage, AK 99519-6650 Subject: Sewer Upgrade — DeArmoun Block 2, Lot 5 Gentlemen: The owner has requested we proceed forward to obtain a septic permit to upgrade and replace the existing septic system and tank for the subject lot. The existing septic tank will be abandoned in place and in accordance with municipal standards. On May 16, 2001 we dug one testhole for the proposed system. The results of this test are attached. The general slope of this lot is flat. We have designed our system utilizing the testhole we excavated for the 3 -bedroom house. The lot is served by an class A well, ADEC#211936. We propose to install a 5' wide deep trench. Water was not encountered during the excavation or monitoring. There are no public or private wells within 200' of our proposed system location except as noted. There is no surface water within 100' of the proposed system and there are no known curtain drains within 50'. We do not expect there to be any adverse effect on adjacent lots by the development of this system. If you have any questions, please contact me at 696-6111/FAX 696-8111. Respectfully submitted, 1KHD Engineering Kenneth M. Duffus, P.E. S attachments: On -Site Well and Sewer Application Wastewater Absorption System Details/Site Plan Soils Log/Percolation Test WELL & WASTEWATER DISP❑SAL SYSTEM DETAILS/SITE PLA DEARMDUN #2, BLOCK 2, LOT 5 9 0 E'3 181 51 NO PUBLIC WELLS WITHIN 200' OF PROPOSED SYSTEM. NO PRIVATE WELLS WITHIN 200' OF PROPOSED SYSTEM EXCEPT AS NOTED, NO SEPTIC SYSTEMS WITHIN 200' OF PROPOSED WELL EXCEPT AS NOTED, AW ��'F...A�gS *49'rH* F KENNETH M. DUFFf7S' `1•., CE -7116 W� Aff 1 \ �FESSIO�� ,v "L LSRt 7 8 1 9 10 111 DESIGN DETAILS 3 BDRM X 150 GPD = 450 GPD 450 GPD/0,13 GPD PER SQ. FT. (6.40 MIN/IN.)= 375 SQ. FT (375/5'(W)) X ,50(RF) (4.0' GRAVEL) = 37.5 FT. TRENCH USE 1 TRENCH - 38 (L) X 5' (W) X 4.0'(D) Total depth of system is B.0' from original grade. Total depth of gravel below dlstrlbutlon pipe Is 4.0' NOTES: 1, USE 1000 GAL. SEPTIC TANK, INSULATE IF C4' OF COVER. 2, INSULATE TRENCH WITH 2' HD BURIAL FOAM, 3. CONTRACTOR WILL ENSURE MINIMUM 2% SLOPE INTO SEPTIC TANK. 4, ADDITIONAL FILL WILL BE ADDED OVER SYSTEM TO ACHIEVE MIN, 3' COVER IF REQUIRED, 5, CONTRACTOR WILL ENSURE ALL SEPARATIONS TO ADJACENT WELLS & SEPTICS, PREPARED FOR; BILL JOHNSON 3700 MATHEWS ANCHORAGE, AK (907) 344-7922 FIELD BOOKS COMPUTED: I 3 89) VBG � �w KMD I DATE I DWG. MM- GRID: 2935 ACAD F E: 01027.DWG 'IOB NO: 01027 I u iy Q Ir I cz ,. 1 2 NO PUBLIC WELLS WITHIN 200' OF PROPOSED SYSTEM. NO PRIVATE WELLS WITHIN 200' OF PROPOSED SYSTEM EXCEPT AS NOTED, NO SEPTIC SYSTEMS WITHIN 200' OF PROPOSED WELL EXCEPT AS NOTED, AW ��'F...A�gS *49'rH* F KENNETH M. DUFFf7S' `1•., CE -7116 W� Aff 1 \ �FESSIO�� ,v "L LSRt 7 8 1 9 10 111 DESIGN DETAILS 3 BDRM X 150 GPD = 450 GPD 450 GPD/0,13 GPD PER SQ. FT. (6.40 MIN/IN.)= 375 SQ. FT (375/5'(W)) X ,50(RF) (4.0' GRAVEL) = 37.5 FT. TRENCH USE 1 TRENCH - 38 (L) X 5' (W) X 4.0'(D) Total depth of system is B.0' from original grade. Total depth of gravel below dlstrlbutlon pipe Is 4.0' NOTES: 1, USE 1000 GAL. SEPTIC TANK, INSULATE IF C4' OF COVER. 2, INSULATE TRENCH WITH 2' HD BURIAL FOAM, 3. CONTRACTOR WILL ENSURE MINIMUM 2% SLOPE INTO SEPTIC TANK. 4, ADDITIONAL FILL WILL BE ADDED OVER SYSTEM TO ACHIEVE MIN, 3' COVER IF REQUIRED, 5, CONTRACTOR WILL ENSURE ALL SEPARATIONS TO ADJACENT WELLS & SEPTICS, PREPARED FOR; BILL JOHNSON 3700 MATHEWS ANCHORAGE, AK (907) 344-7922 FIELD BOOKS COMPUTED: BOUNDARY. LANMARK DRAWN. VBG STAKING: LANMARK CHECKED. KMD Ase T LANMARK DATE 5/16 DWG. MM- GRID: 2935 ACAD F E: 01027.DWG 'IOB NO: 01027 Scale) 1'= 100' PAGE 1 OF 2 lL\�dV J U) ENGINEERING 20441 PTARMIGAN BLVD. EAGLE RIVER, AK 99577-8736 111 WASTEWATER DISPOSAL SYSTEM DETAILS Appw- DEARMOUN #2, BLOCK 2, LOT 5 ka.ff' llla 911111111 FD17) 0 F 1, P PUS G L SE PRO USED US� S Y S (EM c TH# c/ E xj 2x5 FP CANT �SED DIVER R --D 1000 )TIC TANK o o D R194RY C 11 MT 001-01 PORCH � BOUNDARY: LANMARK DRAM: < s m'NG: LANMARK WEC M: KMD AMUILT'- LANMARK— DAM 32.00 DW flM MID: 2935 ACRD NL`: C)1027.DWG "No.. 01027 20.33 EXISTING 3 BDRM HOUI-31-- DECK EXISTING T SEPTIC C.O. 11 SLOPE=FLAT FENCE ,a-ft"6'NkN Idw q.................... OF AZ *j;49 TH* CE—7116 ................... Agr PREPARED FOR: BILL JOHNSON 3700 MATHEWS ANCHORAGE, AK (907) 344-7922 FIELD BOOKS BOUNDARY: LANMARK DRAM: VBG s m'NG: LANMARK WEC M: KMD AMUILT'- LANMARK— DAM 5/16 DW flM MID: 2935 ACRD NL`: C)1027.DWG "No.. 01027 scatel 1'= 20' PAGE 2 OF 2 LtLll LU) ENGINEERING 20441 PTARMIGAN BLVD. EAGLE RIVER, AK 99577-8736 11 SOILS PERCOLATION TEST\�o Rpp sslo� Performed for: Bill Johnson Date Performed: 05/09/01 Project: DeArmoun #2, Block 2, Lot 5 TEST HOLE # 2001-01 Depth (Feet) SEE ATTACHED SITE PLAN 1- 2- 3- 4- 5- 6- 7- 8- 9- to- 11- 12- 13- 14- 15- 16- 17- 18- 19- 20- Org/SM/ fill black/red overburden, organics, w/ SM fill mixed to 4' SP/SM - gray, silty sand damp, w/ cobbles to 18" and gravel, firm density silt increasing w/ depth I uo" HOLE PRESOAKED PRIOR TO TEST FOR HOLE LOCATION Was Ground water encountered? NO What depth? NA Depth to water after monitoring? NA Date? 5/16/01 Reading Date Gross Time Net Time Depth to Water Net Drop IKIqD 5/9/01 ENGINEERING 20441 PTARMIGAN BLVD. ♦ Oit' . Strv4 OaiY EAGLE RIVER, AK 99577-8736''° .. y 1:30 30 min 35/16" 411/16- SOILS PERCOLATION TEST\�o Rpp sslo� Performed for: Bill Johnson Date Performed: 05/09/01 Project: DeArmoun #2, Block 2, Lot 5 TEST HOLE # 2001-01 Depth (Feet) SEE ATTACHED SITE PLAN 1- 2- 3- 4- 5- 6- 7- 8- 9- to- 11- 12- 13- 14- 15- 16- 17- 18- 19- 20- Org/SM/ fill black/red overburden, organics, w/ SM fill mixed to 4' SP/SM - gray, silty sand damp, w/ cobbles to 18" and gravel, firm density silt increasing w/ depth I uo" HOLE PRESOAKED PRIOR TO TEST FOR HOLE LOCATION Was Ground water encountered? NO What depth? NA Depth to water after monitoring? NA Date? 5/16/01 Reading Date Gross Time Net Time Depth to Water Net Drop 1 5/9/01 1:00 8" 2 1:30 30 min 35/16" 411/16- 3 1:31 8" - 4 2:01 30 min 35/16" 411/16" 5 2:02 8" - 6 2:32 30 min 35/16" 411/16" Water Added Percolation Rate 6.40 (min/ in) Pere Hole Diameter 6" Test Run Between 4 feet and 5 feet I, Kenneth M. Duffus, certify that this test was performed in accordance with all State and Municipal guidelines in effect on this date. GARB idDI GRR ANCHORAGE AREA BORO DE RTMENT OF ENVIRONMENTAL OUALI 3500 TUDOR ROAD ANCHORAGE, ALASKA 99507 279-8686 INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM z _: ADDRESS �;7Lt 17 __ !/ _____PHONE ocanoN / �: i /C/T1� �' Llf trEic!S'r�ir/'F�; ------ LEGAL DESCRIPTION/l! _ SEPTIC TANK .r E' NUMBER OF DISTANCE FROM WELL,//Z/;" -�' ���� MATERIAL ��f- _COMPARTMENTS LyLIQUID LIQUID CAPACITY 1 __ _.GALLONS. INSIDE LENGTH -----I N SIDE WIDTH DEPTH SEEPAGE SYSTEM: SEEPAGE PIT G�/'�'l'z`-Llz ' �f L/ NUMBER OF PITS_______ —OUTSIDE DIAMETER OR WIDTH_ /�_ LENGTH <-- DEPTH LINING MATERIAL �L't! lP /�''� —. DISTANCE FROM WELL-- BUILDING FOUNDATIONX� a4 i) NEAREST LOT LINE- ;i'(_ ` -- . TOTAL EFFECTIVE ABSORPTION AREA (WALL AREA) -'%/_ _ SQ. FT. FIELD: DISTANCE FROM NEARESTLOT TOTAL LENGTH OF LINES NUMBER OF LINES —_ _—DISTANCE BETWEEN LINES WIDTH IN. TOTAL EFFECTIVE ABSORPTION AREA _.__ SQ. FT. LENGTH OF EACH LINE----- DEPTH: INE _—._DEPTH: TOP OF TILE TO FINISH GRADE_ DEPTH OF FILTER MATERIAL BENEATH TILE_ IN. ABOVE TILE - WELL; TYPE (er�77 �1: /? DISTANCE FROM WATER DEPTH- BUILDING FOUNDATION.--- SAMPLE , NEAREST NEARE SEPTIC SEEPAGE OTHER LOT LINE —, SEWER LINE ,TANK , SYSTEM__ _ , CESSPOOL , SOURCES— DIAGRAM OF SYSTEM DISTANCES: ti l/T 0�1 z/Vjy I g7 c• S'v,� ,x DATE �_ G' _ / %� APPROVED "'L l- Bc �i-Y`/ L L!l Z. ?�E /, %`lz G.A.A.B. GREW ANCHORAGE AREA BOUGH DEPARTMENT OF ENVIRONMENTAL QUALITY „ 3500 TUDOR ROAD POUCH 6-650 1. ANCHORAGE, ALASKA 99502 %% TELEPHONE 279-8686 SEWAGE DISPOSAL SYSTEM - APPLICATION AND PERMIT NAME OF APPLICANT MAILING ADDRESS v/ � /%✓� . INSTALLATION LOCATION ��!�������✓/�/��'� - LEGAL DESCRIPTION- CL•l� PERMIT NO. PHONE INSTALLATION OF. SEPTIC TANK -r' / SEEPAGE PIT / DRAIN FIELD OTHER , TYPE AND SIZE OF FACILITY TO BE SERVED �%�--' � / //�/ �f /J�:�l�✓f���z� - FINANCED THROUGHy' TO BE INSTALLED BY �✓� J /�l SOIL TEST RESULTS --S NOTE: THIS PERMIT IS NOT VALID WITHOUT SOIL TEST COMPLETION DATE ANTICIPATED z / / z -- FINAL INSPECTION: 24 HOUR NOTICE REQUIRED. BACKFILLING OF ANY SYSTEM WITHOUT FINAL INSPECTION BY THE HEALTH DEPARTMENT AUTHORITY WILL BE SUBJECT TO PROSECUTION. SEPTIC TANK SIZE TYPE MINIMUM DISTANCES, REQUIREMENTS FOUNDATION TO SEPTIC TANK FOUNDATION TO SEEPAGE PIT =� �` C DRAIN FIELD SEPTIC TANK TO SEEPAGE PIT WALL SEPTIC TANK `!�- , SEEPAGE PIT -2 U DRAIN FIELD TO NEAREST LOT LINE. WELL TO SEPTIC TANK SEEPAGE PIT SEEPAGE AREA SIZE DRAIN FIELD _- / ALSO CONSIDER AREA WELLS. WATER MAIN TO SEPTIC TANK r �� SEEPAGE PIT DRAIN FIELD SEPTIC TANK, t `5 SEEPAGE PIT ��, DRAIN FIELD TO RIVER, LAKE, STREAM. CAST IRON INTO AND OUT OF SEPTIC TANK AND INTO CRIB CROSSING GAP OF EXCAVATION 5 FEET INTO UNDISTURBED SOIL. 4 INCH DIAMETER CAST IRON SIPHON PIPES ON SEPTIC TANK AND SEEPAGE PIT FITTED WITH AIRTIGHT REMOVABLE CAPS. GRAVEL BACKFILL CONFORM TO BOROUGH REGULATIONS REGARDING INSTALLATION. c'z.�/�� HEALTH AUTHORITY OR LICENSED DESIGNER DIAGRAM OF SYSTEM I CERTIFY THAT 1 AM FAMILIAR WITH THE REQUIREMENTS OF GREATER ANCHORAGE AREA BOROUGH ORDINANCE NO. 2868 AND THAT THE ABOVE DESCRIBED SYSTEM IS IN ACCORDANCE WITH SAID CODE. DATE / APPLICANT'S SIGNATURE Municipality of Anchorage On -Site Water & Wastewater Program (907) 343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL Parcel I.D. 018-401-34 r Expiration Date 3 1. GENERAL INFORMATION Complete legal description DEARMOUN SID #2; BLOCK 2, LOT 5 Location (site address) Current Property owner(s) Mailing address Real Estate Agent 3700 MATTHEWS DRIVE, ANCHORAGE, AK, 99516 RUSSELL OAKELEY Day phone 903-6629 3700 MATTHEWS DRIVE, ANCHORAGE, AK, 99516 _ HEATHER DAMASSIOTIS W/ KELLER WILLIAMS Day phone 2. TYPE OF DWELLING: 0 Single Family (w/wo ADU) ❑ Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) 3. NUMBER OF BEDROOMS: 4 4. TYPE OF WATER SUPPLY: 830-6540 TYPE OF WASTEWATER DISPOSAL: Individual Well ❑ Individual On-site 0 Individual Water Storage ❑ Individual Holding tank ❑ Community Class A Well 0 Community On-site ❑ Public Water System ❑ Public Sewer ❑ waiverNariance request for NIC Received by: 7-6&-4-i AEXeia 4A_,wy' COSA to be released to the engineer, unless otherwise requested by the engineer. Date: _f // zz f COSA Fee $ 14 2OI • 6G Waiver Fee $ Date of Payment ��3 / [ �( Receipt Number OL 3 3M5J ��1L� G COSA 4JG (S O J Date of Payment Receipt Number Waiver # Distance: 5.. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, t verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm GARNESS ENGINEERING GROUP, Ltd. Address 3701 E. TUDOR ROAD,SUITE 101 `ANCHORAGE, AK, 99507 Engineer's Printed Name JEFFREY A. GARNESS, P.E. Engineers Comments: In conducting this evaluation, GEG provided an engineering evaluation ofthe well andlm septic system in accordance with the guidelines and regulations established by the kfunio%palilyotAnchorage and iadusfrypradices. The reported results describe the condition of the systemes on the dailies of fhe evaluation. Separation distances were measurable madAyidenbTiable features. Hidden defects orencroachments may exist that were not identified during the evaluation. The operalionanife Ball wells and septic systems depend an a variety of variables including, but not limited to, soil conditions, groundwater levels (that mayNuctuate during the year), quality ofconsoucfion (materials and workmanship), and the wafer usage of the family utilizing the systemrs. These condilhons can vary, and are outside the control of GEG. Satisactory, test results do not guarantee future performance of the systeMs therefore, GEG makes no warranty (express or implied) regarding the future performance of the well or septic system. GEG makes no representation whether an alternative well or sepflc system can be installed on the prop any in the event either of the current systems (ail. The content of this report is far the sale benefit of the persoNparty, who retained GEG. Reliance upon the infatuation provided in this report by any other person or party, including hot not limited to subsequent property, purchasers, is not authorized. In short, GEG disavows any legal duty to anyone other than the person oady who paid for thisrepod. 6. DSD SIGNATURE System #1 Approved for --t— bedrooms. System #2 Approved for Disapproved. Conditional approval for bedrooms. bedrooms, with the following 337-6179 Date OF I:—``, *ZN 141t lfi a.\�P�\AY OFANCyo ,G =J= ON-SITE -� WATER AND m WASTEWATER o �. PROGRAM Original Certificate Date: 3 l �q - 1 The Mdrficipgfff y o✓ArL6hoirage Develop, emt Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the represar atations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTCHMENTS: COSA Checklist Septic System Advisory Well Flow Advisory (Rev. 10112112) ✓� Nitrate Advisory Arsenic Advisory Other If more than 1 septic system is on the lot: COSA Checklist # of Structure served by this system Certificate of On -Site Systems Approval Checklist Legal Description: A. WELL DATA Well type COMMUNin Date completed Total depth ft. DEARMOUN S/D #2; BLOCK 2, LOT 5 Parcel ID: 018-401-34 If A, B, or C provide PWSID# 211936 Well Log (Y/N)- Sanitary seal (Y/N)_ Wires properly protected Cased to ft. Casing height (abo n FROM WELL LOG AT Date of test Static water level ft. ft. Well production go -P.M. g.p.m. WATER SAMPLE RES Coliform colonies/100 ml. Nitrate mg./L. Collected by: Ars�emc. ug./L. Date of sample: B. SEPTIC/HOLDING TANK DATA Tank Type/Material S.T.E.P./STEEL Date installed 3/2/2015 Tank size 1500 gal. Number of Compartments 2 Cleanouts (Y/N) YES Foundation cleanout (Y/N) YES Depression over tank (Y/N) NO High water alarm (Y/N) YES Date of pumping NEW Pumper in. C. ABSORPTION FIELD DATA aeLOwFiNALCRnoe Date installed 3/2/2015 Soil rating .p.d./or ft2/bdrm) 10 System type DEEP TRENCH 2@25' Length 50 TOTAL ft. Width 2.5/2.5 ft. Gravel below pipe 6.0/6.0 ft. '8.9/ Total depth '8 3-89 ft. Eff. absorption area 600 ft2 Monitoring tube YES Depression over field NO Date of adequacy test NEW Results (Pass/Fail) For=bedrooms Fluid depth in absorption field before test in. Water added =gal. New depth =in. Elapsed Time: = min. Final fluid depth in. Absorption rate >= 600+ g.p.d. Any rejuvenation treatment (past 12 mo.) (Y/N & type) NONE KNOWN If yes, give date OLD TRENCH WAS CONNECTED AS ALTERNATE SITE. SEE MOA DOCUMENTATION FOR ALTERNATE SITE INFO. D. LIFT STATION 'TO FLOAT TETHER CLAMP. Date installed 3/2/2015 Size in gallons 1500 Manhole/Access (Y/N) YES "Pump on" level at ;42 in. "Pump off' level at `42 in. High water alarm level at '46 in. Datum BOTTOM OF BASKET Cycles tested NEW Meets alarm & circuit requirements? YES E. SEPARATION DISTANCES SEPARATION DISTANCES FROM WELL ON LOT TO: Septic tank/lift station on lot Absorption field on lot Public sewer main Sewer /septic service On adjacent On adjacent lots Holding tank COMMUNITY WELL manhole/cleanout Ap4nal -containment areas Manure/animal excrete storage areas — SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundation 5'+ Property line 51+ Absorption field 54 Water main 104 Water service line 10'+ Surface water 100'+ Wells on adjacent lots 200'+ PUBLIC/100'+ PRIVATE SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line 10'+ Building foundation 10'+ Water main 10'+ Water service line 10'+ Surface water 100'+ Driveway, parking/vehicle storage 10'+ Curtain drain NONE KNOWN Wells on adjacent lots 200'+ PUBLIC/100'+ PRIVATE F. COMMENTS G. ENGINEER'S CERTIFICATION I certify that I have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this date. Engineer's Printed IN me JEFFREY A. GARNESS Date J 7 (Rev. 10112112) 5' 1r�hj...•. p/ OFESSI��i Nam --- % eXtFNO mmo f100R Ntv. (ANLY•D) �asr an t wa,Lrt F- _ _ _ _ _ _ _ _ Zauxt OltartT MATTHEWS DRIVE M eeAR "`aH0 "m N890 56'00"W 99.96' 0 C.O.X2 ....... �F TI ! O.S.07 ° 20.aLu W06 N N EXISTING a 0 0 CD a HOUSE o •- `- 20.4' 23.6' Q z 32.0' .N C.O. 6 I w I CO..1C 3KID M.H:d IN . o W m a C.O S SHED I N89° 56' 00"W 120.00' 30' a I 7 UNDER NO CIRCUMSTANCES SHOULD AN AS -BUILT BE USED FOR CONSTRUCTION OR FOR ESTABLISHING BOUNDARY OR FENCE LINES. THE SURVEYOR TAKES RESPONSIBILITY FOR THE INITAL TRANSACTION ONLY AND ASSUMES FINANCIAL LIABILITY ONLY FOR THE COST OF THE SURVEY. LISTED DISTANCES PREVAIL OVER SCALING. MAY CAUSE ERRORS IN SCALE. _REPRODUCTION LOT SURVEY SURVEY TYPE SYMBOLS FWNDATON AS-91JILT ❑ Fll1AL smuCNRE A WILT ' SET � W DRAINAGE 0 ASPHALT ❑ PLOT PIAN ... AS-BWLT.. ,LOT s11IVEY ... TOPaDRAPNY DRE o FOUND REBAR g__6 a WOOD FENCE '"'` CONCRETE A — ! RECER nD11 As—BUILT .. m ms ser 00 s ASSUMED ELEV. Y„ —* 'METAL FENCE ® WOOD DECK PLOT PLANS & LOT SURVEYS NOTE: IT IS 'THE RESPONSIBILITY OF THE BUILDER OR OWNER, PRIOR TO ONLY THOSE IMPROVEMENTS ABOVE GROUND AND VISIBLE WILL BE CONSTRUCTION, TO VERIFY PROPOSED BUILDING GRADE RELATIVE SHOWN. FENCES, WELLS, SEPTIC CtEANOUTS, SIDEWALKS, DRIVEWAYS, TO FINISHED GRADE AND UTILITY CONNECTIONS AND TO DETERMINE ETC., ARE SHOWN IN THEIR APPROXIMATE LOCATION, ONLY. SNOW THE EXISTENCE OF ANY EASEMENTS, COVENANTS OR RESTRICTIONS MAY PREVENT SOME IMPROVEMENTS FROM BEING SEEN AND LOCATED. WHICH DO NOT APPEAR ON THE RECORDED SUBDIVISION PLAT. ALL DISTANCES ARE RECORD UNLESS OTHERWISE NOTED. SURVEY CERMFICATION ••����i� p� Prepared by PLOT PLAN OF % Robert E. Johns, Jr. & Assoc. „-eyWN."",aF..*`."'�,,.' •.•.�E WY\ .. . .••' �1� Professional Land Surveyors ne•. r,,. > wlsax.e au a sb be ..m•. a• °r "a - % .• . 1700 Bonk Drive. z = �.�arMear, iw•. ern I # t � � • ANCHORAGE, ALASKA 99504 Sea e: „ 1 = 30 Rea Lot S.F. Ree. Plat File No. FOUNDATION AS -BUILT 00 49th ..th .r. .... •_ ,'.•• •.` •...r eu,Lr... o n. 0 ,.. .. .. Dote Surveyed; '° 03/09/15 Drawn by: REJ CheekeA b d" Mab wW:'t': ROBERT E. JOHNS, JR. f ; 'Ar MK Date Drawn: `"Id 'o.. ai 2� _S ���� 03/10/15 2935 w'0' 15-77 FIN& STRUCTURE FlNAL STRUCTURE AS -BUILT I. NMt E A`Me1 x, Ii,rCY rrarr na, , �•.; �� A,'VI • �1 �. /e •••,,. Legal Description: •e per' • • ••,: ��t ,,06 'Lot W mG m w„wMinb ,Y1 uiA DEARMOUN#2 Municipality of Anchorage Development Services Department Building Safety Division g- On -Site Water and Wastewater Program ° 4700 South Bragaw St. r P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907) 343-7904 CERTIFICATE OF HEALTH AUTHORITY APPROVAL FOR A SINGLE FAMILY DWELLING Parcell.D. 018-401-54 HAA 1. GENERAL INFORMATION Expiration Date: 6- 11-02 ' Complete legal description DeArmOLn # , Block 20 Lot 5 Location (site address or directions) 3700 Mathews Drive, Ancti age AK S o Current Property owner(s) WilliamE-Jhnson Dayphone 344-7922 Mailing address dame as ahoy Lending agency Day phone Mailing address Real Estate Agent Ainslie Phillips Dayphone 274-7242 Mailing Address PrudentialVista BE, 4241 B Street Anchorage, AK 99503 Unless otherwise requested, HAA will be held by DSD for pickup. 2. NUMBER OF BEDROOMS: 3 3. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well ❑ Individual On-site Individual Water Storage ❑ Individual Holding tank Community Class Well ❑ Community On-site Public Water System ® Public Sewer The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of Health Authority Approval (HAA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. Certificates of Health Authority Approval are required for the transfer of title (except between spouses) for properties served by a single family on-site wastewater disposal and/or water supply system. DSD also issues HAAs upon request to homeowners. Certificates of Health Authority Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued with new water sample results less than 30 days old. (Certificates may be reissued for a period of up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 4. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Health Authority Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is(are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of FirrrL-K—N—D Enalneering . Phone 9 ,. Engineer's Printed Name Kenneth M. Duffus Date 05/31/01 OF AtQ%1j .e 4feresuo+a•�ooee•.�r�=•• Sl Af',IP 5. DSD SIGNATURE PA s^• C 7116 Approved for bedrooms. ��9FOP•,,,®„,e.�P�`'a Disapproved. Conditional approval for bedrooms, with the following stipulations: Additional Comments Attachments: HAA Checklist X Septic System Advisory Well Flow Advisory v ON-SITE, WATER Anfn WASTEWATER PROGR,Ai�i pp� lJ�/Ji�j4j7�s�- Maintenance Agreements Supplemental Engineer's Report Other Original Certificate Date: - ��� C) Municipality of Anchorage Development Services Department Building Safety Division On -Site Water & Wastewater Program :9 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.cl.anchorage.ak.us (907) 343-7904 HEALTH AUTHORITY APPROVAL CHECKLIST Legal Description: DeArmoun #2. Block 2 Lot 5 Parcel ID: 018-401-34 A. WELL DATA Well type A If A, B, or C provide PWSID # 211936 Well Log (YIN) Date completed Sanitary seal (Y/N) Wires properly protected (YIN) Total depth ft. Cased to ft. Casing height (above ground) FROM WELL LOG AT INSPECTION Date of test Static water level ft, ft. Well production g.p.m g.p.m. WATER SAMPLE RESULTS: Coliform colonies/100 ml. Nitrate mg./l. Other bacteria_colonies/100mi Date of sample: Collected by: B. SEPTIC/HOLDING TANK DATA Tank Type/Material Steel - Greer Date installed 05/31/01 Tank size 1000 gal. Number of Compartments Cleanouts Y Foundation cleanout Y Depression over tank N High water alarm NA Date of pumping New tank Pumper C. ABSORPTION FIELD DATA Date installed 05/31/2001 Soil rating (g.p.d./ft2 or ftz/bdrm) 0_8 System type Trench Length 41 ft. Width 5 ft. Gravel below pipe 4.0 9 ft. Total depth 8.93 ft. Eff. absorption area 410 ftz Monitoring tube Y Depression over field N Date of adequacy test New System Results (Pass/Fail) _ For 3 bedrooms Fluid depth in absorption field before test in. Water added_ gal. New depth in. Elapsed Time -.min. Final fluid depth in. Absorption rate >= g.p.d. Any rejuvenation treatment (past 12 mo.) (YIN & type) If yes, give date D. LIFT STATION Date installed NA Size in gallons Manhole/Access (Y/N) "Pump on" level at in. "Pump off' level at in.High water alarm level at in. Datum Cycles tested E. SEPARATION DISTANCES SEPARATION DISTANCES FROM WELL ON LOT TO: Septic tankilift station on lot NA Absorption field on lot NA Public sewer main NA Sewer /septic service line NA Meets alarm & circuit requirements? On adjacent lots NA On adjacent lots NA Public sewer manhole/cleanout NA Holding tank NA SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundation 51+ Property line 5 ' + Absorption field 5 ' + Water main 10'+ Water service line 1 0 ' + Surface water 10 0 ' + Wells on adjacent lots 200'+ SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line 3' Building foundation 1 0 ' + Water main 1 0 ' + Water Service line 101+ Surface water 10 0 ' + Driveway, parking/vehicle storage 2 5 ' + Curtain drain 50'+ Wells on adjacent lots 2 0 0 ' + F. COMMENTS G. ENGINEER'S CERTIFICATION I certify that I have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA NAA guidelines in effect on this date. Engineer's Printed Name Kenneth M. Duffus Date 05/31/01 HAA Fee $ 300 Date of Payment OfD,lOtrt2001 Receipt Number 7 3 (Rev. 12100) 4 EFTA* Waiver Fee $ //S Date of Payment0(p� I Receipt Number .5773 24