ON-SITE WASTEWATER INSPECTION REPORT
Permit Number: OSP1.41214 PID Number: 051-333-09 ❑ New ❑✓ Upgrade
Sara Benson
18607 Fish Hatchery Road
of Bedrooms
3
I Fere Lake, Tract E 3
SEPARATION DISTANCES
To
From
Septic
Tank
Absorption
Field
Lift Station
Holding
Tank
Sewer
Line
Well
109.4
103.1
109.4
N/A
100+
Surface Water
75
57.7
75
N/A
Lot Line
75.4
74.0
75.4
N/A
NA
Foundation
5.0
12.7
5.0
N/A
Curtain Drain
N/A
NIA
N/A
N/A
3'" 41h
Remarks
3SORPTION FIELD
❑ Deep Trench ❑✓ Shallow Trench ❑ Bed ❑✓ Mound
❑ Other
iI Rating Total depth from original grade
1.2 GPD/SF 4.d Ft.
pth to pipe invert from original grade Gravel depth beneath pipe
1.0 Ft. 3.0 Ft.
added above original grade Gravel length
1.5 Ft. 45.0 Ft.
avel width Beds: Number of Lines Distance between lines
5.0 Ft N/A N/A Ft
i area Number of trenches
388 Fe 1
Septic E) S.T.E.P. ❑ Holding [
C
Tank/ Orenco
STEEL
'ATION
Orenco I 250
'ump on level at jPump off level at lHiqh water alarm at
2
itional Approval:
Approved
inspection raeport_1-1-1z.aoc
Date
Date `0
43 in,
40 in.
45 in.
Pump make and model
P2005
Electrical
Inspections performed
by
PIPE MATERIAL House to tank
3034d Tank
3034Tank to
3034
Installer
JR's Septic Pumping
Drainfleld
3034 CO/MT
3034
Inspector Pannone Engineering Services
BENCHMARK (Assumed elevation)
10011
Inspection is 7/31/2014 a 8/1 /2014
Location and description
dates: 2^
Top of slab, outside back door.
3'" 41h
COMMUNITY DEVELOPMENT DEPARTMENT APPROVAL
Engineer's Stamp
itional Approval:
Approved
inspection raeport_1-1-1z.aoc
Date
Date `0
G
CONSTRUCTED NEW LANDSCAPE BERM
TO CREATE MIN 100' PATH FROM ANY
PART OF THE DRAIN FIELD FOP, POTENTIAL
_ EFFLUENT SPILL TO SURFACE WATER
I i
57.7
I �
ITH-1 z
66 /# .
P/
v
P
� I
J -2A
f
NOTES.
RECORD DRAWING
PLAN
INSTALLED NEW DRAIN FIELD
45LF x 5.0'W x 3.0'ED x 4.0'TD
MAINTAINED 5' MIN SEPARATION TO TEST HOLE
\1 B 3BR
`T1 HOUSE
(E)
A AA
T2 ABANDON CESSPOOL (E) PER CODE
REMOVED ANY PORTION WITHIN 10' OF
PROPOSED FIELD AND REPLACED W/ CLEAN
NATIVE SOIL OR APPROVED EQUAL
� � h
1250g S.T.EP. TANK (P)
1�
WILLL (E) 5.
E
FISH HATCHERY ROAD
SEPTIC AREA (E)
�� WELL (E)
1
w-_IW—�/
11
11 \
3
SEPTIC AREA (E)
PANNONE ENG SVC, LLC
P.O. BOX 100217 ANCHORAGE, AK 99510
PHONE (907) 272-8218 FAX (907) 272-8211
FIRE LAKE, LOT 3, TRACT E
SARA BENSON
18607 FISH HATCHERY ROAD
EAGLE RIVER, AN 99577
WELL (E)
.C+kq,`Aj, 10/6/2014
*-"4 *.�) 1 —so'
P.LD- NO
-051-333-09
Steven R. none PERMIT NO.
PF. CE 8149 .'<�/� OSP141214
��s'. ,.•fir
I`t%ROEES"` � Sh2 eOF 3
A
6
FC
12.6
18.8
T1
14.5
21.1
-2
T2
18.1
27.3
LS
19.3
29.0
M2
16.2
33.7
57.7
I �
ITH-1 z
66 /# .
P/
v
P
� I
J -2A
f
NOTES.
RECORD DRAWING
PLAN
INSTALLED NEW DRAIN FIELD
45LF x 5.0'W x 3.0'ED x 4.0'TD
MAINTAINED 5' MIN SEPARATION TO TEST HOLE
\1 B 3BR
`T1 HOUSE
(E)
A AA
T2 ABANDON CESSPOOL (E) PER CODE
REMOVED ANY PORTION WITHIN 10' OF
PROPOSED FIELD AND REPLACED W/ CLEAN
NATIVE SOIL OR APPROVED EQUAL
� � h
1250g S.T.EP. TANK (P)
1�
WILLL (E) 5.
E
FISH HATCHERY ROAD
SEPTIC AREA (E)
�� WELL (E)
1
w-_IW—�/
11
11 \
3
SEPTIC AREA (E)
PANNONE ENG SVC, LLC
P.O. BOX 100217 ANCHORAGE, AK 99510
PHONE (907) 272-8218 FAX (907) 272-8211
FIRE LAKE, LOT 3, TRACT E
SARA BENSON
18607 FISH HATCHERY ROAD
EAGLE RIVER, AN 99577
WELL (E)
.C+kq,`Aj, 10/6/2014
*-"4 *.�) 1 —so'
P.LD- NO
-051-333-09
Steven R. none PERMIT NO.
PF. CE 8149 .'<�/� OSP141214
��s'. ,.•fir
I`t%ROEES"` � Sh2 eOF 3
SPECIAL PROVISIONS TO SPECIFICATIONS
1 . ALL CONSTRUCTION WAS INSTALLED AS SPECIFIED IN THE MOST CURRENT EDITION OF THE MUNICIPALITY OF ANCHORAGE
STANDARD SPECIFICATIONS (MASS) FOR COMPONENT PARTS AND MATERIALS
USED IN. CONSTRUCTION OF ON—SITE
WASTEWATER DISPOSAL SYSTEMS AND ATTACHED PES SPECIAL PROVISIONS.
2. SCOPE OF WORK: INSTALLED NEW 1250g S.T.E.P. TANK AND SOIL ABSORPTION SYSTEM, CONSTRUCTED LANDSCAPE
BERM
3. GROUNDWATER WAS OBSERVED AT A DEPTH OF 9.0 FEET BELOW EXISTING GRADE AS EVIDENCED BY THE SOIL TEST
HOLE. AN APPARENT WATER TABLE WAS NOT OBSERVED IN ANY OF THE EXCAVATIONS LESS THAN 9.0 FEET BELOW
EXISTING GRADE.
BERM
PROVIOa%INIMUM F4-6f'COdEia
-
IBR RIGID INSULATION
SWALE
1➢" 0 DRAIN PIPE W/BERM
HOLES 18"O.C.
C 5,
�1ILT
FILTER FABRIC
0.5 �
MIN S
DRAIN ROCK 6'
ABOVE PIPE INVERT
MIN
MIN
99.3 /
2.0 978
ALE SECTION
SWALE
D 1OR
96.8 -- -.3�� ' -19
10
93.8
I GM/
ORAr
DRAIN ROCK
5.0 SM -
93,9
PATy 33CF C
1
X98866
GM
98.3 O
SECTION
'A
FP
Z Z m RICK INSULATION
0, �r-FIVER FABRIC m
�4 X.
ZQ DRAIN ROCK o' ABOVE PIPE INV r
98,0
00W 1)4" 0 DRAIN PIPE W/
�'�1 /8" HOLES 18" O.C. In
002
I
SWALE PLAN
4-0 -
TRENCH SEE DESIGN
95.8 1250 g S.T.E.P.
TANK (P)
PROFILE
ABBREVIATIONS
COPPER
DESIGN PARAMETERS
DI N PIPE
D
IHOLE
UPGRADE SEPTIC SYSTEM LEGEND
TH TEST
NO. BEDROOM: 3 (450 gpd) WATER LINE/
FC FOUNDATION CLEAN OUT
TANK SIZE: 1250g S.T.E.P. - W_
WELL RADIUS
T# TANK CLEAN OUT NO.
PERC RATE = 3.1 MPI
SOIL RATING: 1.2 GPD/SF
C# CLEAN OUT NO.
SS NEW SEPTIC
AREA ROD: 375 SF
M, MONITOR TUBE NO.
�
SYS. TYPE: WIDE TRENCH 3.0" E.D.
R.I. RIGID INSULATION
RF: 0.58
DCO DOUBLE CLEAN OUT
MIN LENGTH: 43.5 LF
OV DIVERTER VALVE -
FS FLOW SPLITTER
USED:
BFG BELOW FINISH GRADE
45 LF X 5' WIDE, 3.0' E.D., 4.0' TD
OG ORIGINAL GRADE
TOTAL .AREA: 388 SF
FG FINISH GRADE
TS&V TOPSOIL & VEGETATE
NOTES:
PANNONE ENG SVC, LLC
P.O. BOX 100217 ANCHORAGE, AK 99510
PHONE (907) 272-8218 FAX (907) 272-8211
—�`o�F, a ���
:`(�,. .L.q l`�
r S
%g�P �9 t�1
j.. 4.. ... .. .*frl
Date
10/6/20141
RECORD DRAWING
Scale
NI TS
NO
FIRE LAKE, LOT 3, TRACT E
'e'ven '''n'
-a3a-o9
SARA BENSON
18607 FISH HATCHERY ROAD
St R. an e j
9�„, CE 8149 .j`r%
f c, � �
+�isT�Fa..•..NPV
PERMIT No. OSP141214
Sheet
DESIGN DETAILS
EAGLE RIVER, AK 99577
�� ROFESSIO
3 OF 3
On -Site Wastewater Disposal System Permit
MUNICIPALITY OF ANCHORAGE
Development Services Department
On -Site Water & Wastewater Program
4700 Elmore Road, PO Box 196650
Anchorage, AK 99519-6650
Telephone: (907) 343-7904
Permit Number: OSP141214
Tax Code Number: 05133309000
Work Type: Septic Upgrade
Permit Effective Dates: July 02, 2014 to July 02, 2015
Design Engineer: PANNONE ENGINEERING SERVICE
Subdivision: FIRE LAKE
Site Legal Address: FIRE LAKE LT 3 TR E G:0554
Owner/Address: BENSON SARA
402 GREDING ST BLUFFTON OH 458170000
Site Mailing Address: 18607 FISH HATCHERY RD, Eagle River Lot Size in Sq Ft: 20909
Total Bedrooms: 3
This permit is for the construction of:
Y Disposal Field Y Septic Tank N Holding Tank N Privy N Private Well N Water Storage
All construction must be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater
Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80).
3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services
Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either:
A. Open and Close on the same day.
B. Covered, sealed, and heated to prevent freezing.
Received
Issued By
By Date ' L
Date: ?� V
Municipality of iir
P.O. Box 196650 0 4700 Elmore Road
Anchorage, Alaska 99519-6650 ! (907) 343-7904 0 Fax (907) 343-7997
http:tlwww.muni.org/Onsite
Development Services Division
On -Site Water and Wastewater Program
Waiver#: OSP141215 COSA#: Permit#:OSPI41214
m.en t
a
Department
PID#: 051-333-09
Legal Description: Fire Lake, Lot 3, Tract E T h i S Q-
se.P-N
Engineer: PES CLAfl. OfFY-t�ve� p�joeN
X%s-�+n,eo`9".'7
io 5 )��ll Same
Applicant: Sara Benson us+ IRcAa"iof\S� � berm +0
rvy\. ,t h Zn, p la �� RM C
Your request for a waiver of the required 100 feet horizontal separation from the absorption field (�/3olLoLt
to the surface water has been approved. The approved separation distance is 50.0 feet.
This waiver approval applies to the proposed absorption field only. Any future upgrade to the
on-site wastewater disposal system will require all separation distances be met or another
approval from this department.
❑ The affected adjacent property owner(s) have been given a 7 day notice regarding this
waiver.
❑ Notarized letter(s) of non -objection have been received from the .o�vner(s) of the affected
adjacent property.
® Adjacent properties are not affected by this waiver.
■rvvarrrvvverrvvrsvrvarrmvrrervrmrrmevvravrvvrmrrrrrarrvrrrrvvvrrerrrrvrvravvr�
Waiver is Granted: X Waiver is not Granted:
Date:a� l Approved rb
—Reviewer
I-r—ame of Reviewer
.rrr.r.rrmrm.rr.mr...rr..rr.rr..rrr.rmrrr.rrrrrmmrrrrrmrmr.rrrr..rrrrrrrr..rr.r
MUNICIPALITY OF ANCHORAGE
Community Development Department - Phone: 907-343-7904
Development Services Division Fax: 907-343-7997
On -Site Water & Wastewater Program
ON-SITE SEWER/WELL PERMIT APPLICATION
Parcel I.D. 051-333-09
Property owner(s) Sara Benson
Day phone
Mailing address 18607 Fish Hatchery Road, Eagle River, AK 99577
Site address 1$607 Fish Hatchery Road
Legal description (Sub'd., Block & Lot) Fire Lake, Lot 3, Tract E
Legal description (Township, Range & Section)
Lot Size 20,909 Sq. Ft. Number of Bedrooms 3
APPLICATION IS FOR:
APPLICATION IS AN:
TYPE OF DWELLING:
(® all that apply)
Absorption Field
Q
Initial ❑
Single Family (SF)
(w/wo ADU)
Septic Tank
0
Upgrade 0
Duplex (D)
Holding Tank
❑
Renewal ❑
Multiple Dwellings
Privy
F-1(?F
and/or,Q)�
Private Well
❑
Water Storage
❑
JUN"
1 9 2014
THIS APPLICATION
INCLUDES A VARIANCE / WAIVER
REQUEST FOR:
Septic System to Surface Water Distance: 50
I certify that the above information is correct. I further certify that this is in accordance with
applicable Municipal Codes.
(Signature
property owner or authorized agent)
Permit/Rush Fees: 15
1:061 , Waiver Fees: Z
Date of Payment (a 6 M Date of Payment: (,I t
Receipt Number. 63101 I Receipt Number: C)�ybcl 1
Permit No. 05191 121`1 Waiver No. C�vP/q) 24 5
Permit App__-
❑X
Pannone Engineering Services LLC
Steven R. Pannone, Principal
Registered Professional Engineer
E-mail: steve@panengak.com
July 1, 2014
Municipality of Anchorage
Development Services Department
On -Site Water & Wastewater Program
4700 Elmore Road
P. O. Box 196650
Anchorage, Alaska 99519
Subject: Fire Lake, Lot 3, Tract E
Septic System Upgrade Permit Request
Ladies and Gentlemen:
I am writing to request a permit to construct an upgraded septic system be issued for this property. The
proposed systems will serve an existing three-bedroom house. Currently the lot is developed. The
previous septic system was an undocumented cesspool. The cesspool will be abandoned per code. If any
part of the existing cesspool is encountered within 10' of the new field it will be removed along with any
biomatted material and replaced with clean native soil or approved equal. The lot is served by a private
well, that is located over 100' from this system. There surrounding developed lots are also served by
private wells that are over 100' from this system.
1. Soils. A single test hole was excavated by Pannone Engineering Services and the ground water
monitored for seven days. Groundwater was monitored to a depth of 9 feet after the seven day
monitoring period. Bedrock was not encountered in the test hole. It is my opinion, based on the results of
the percolation tests and overall soils appearance; an application rate of 1.2 gallons/day/square feet
should be used for a conventional waste water system.
2. Soil Absorption System Design.
a. See Sheet 2 of the design package
3. Surface Water: Upper Fire Lake and the stream exiting the lake are located 50.2 and 52.4 feet from
the proposed drain field respectively. See waiver request.
4. Topography: The topography in the area generally slopes to the north at approximately 3%-5% in
the area of the proposed drain field.
5. Waiver Request: I request a drain field to surface water waiver of 50 feet from the septic system.
Mounds will be built to ensure a drainage path that flows a minimum of 100' before any chance of
Mailing: P.O. Box 100217, Anchorage, AK 99510-0217
Physical: 332 East I'Vianor Ave, Anchorage, AK 99501
Telephone: (907) 272-13218 FAX: (907) 272-8211
Page 2 of 2
encountering surface water. Granting this waiver will not impact current or future development on any of
the surrounding lots, nor will it impact the water quality of the nearby drainage.
6. Drawing Markings: The Drawings are marked "For MoA Review Only". When written notification
that the review is complete and that there are no further comments is received from MoA On -Site
Department, the note will be removed and `Issued for Construction" drawings will be issued.
The proposed installation will not affect the future development of the surrounding or existing lots. There
are no wells or septic systems within 100 feet of the proposed septic location.
If you have any questions or concerns, please contact me at 272-8218.
Sincerely,
Steven R. Pannone, P.E.
Owner/Civil Engineer
Attachments
-Soils Log
-Septic System Design
,sailing: P.O. Box 100217, Anchorage, AK 99510-0217
Physical: 932 Fast Manor Ave, Anchorage, AK 99501
Telephone: (907) 272-9218 FAX: (907) 272-8211
CONSTRUCT LANDSCAPE BERM (P)
TO CREATE MIN 100' PATH FROM ANY
PART OF THE DRAIN FIELD FOR POTENTIAL INSTALL DRAIN FIELD (P)
EFFLUENT SPILL TO SURFACE WATER 45LF x 5.0'W x 3.0'ED x 4.0'TD p .7
MAINTAIN 5' MIN SEPARATION TO TEST HOLE
50.2 ,
TH-1
ri
HOUSE
y5 (E) M
52.4 �` 1'` ABANDON CESSPOOL (E) PER CODE
REMOVE ANY PORTION WITHIN 10' OF
PROPOSED FIELD AND REPLACE W/ CLEAN
NATIVE SOIL OR APPROVED EQUAL
G� 1250g S T.E.P. TANK (P) \
101.4
105.1
����� �� WELL (E) 3
�� a E�`
J -2A
FISH HATCHERY ROAD
N\ �- SEPTIC AREA (E)
E WELL (E)
WELL (E)
/ 3 SEPTIC AREA (E)
NOTES: ����
p0 L1�T/1 CC7! TT! Date
FOR CONSTRUCTION P.O. BOI 1`21 INCH JYL' LLC .... .... Is � 7/1 /20t4
P.O. BOX 100217 ANCHORAGE, AK 99570 r�P�• ' S� + Scale
PHONE (907) 272-8218 FAX (907) 272-8211 * .49TH *�"=so'
� ......... e$ }. t . .... � P.I.D. NO
FIRE LAKE, LOT 3, TRACT E �'a `.- — oet-as3-oe
SARA BENSON Steven R. Pannone / PERMIT N0.
, �P� CE 8149 �� OSP141214
18607 FISH HATCHERY ROAD � c _
PLAN EAGLE RIVER, AK 99577 '�1��.........Sheet
��\9 S9 1 OF 3
SPECIAL PROVISIONS TO SPECIFICATIONS
1. ALL CONSTRUCTION SHALL BE INSTALLED AS SPECIFIED IN THE MOST CURRENT EDITION OF THE MUNICIPALITY OF
ANCHORAGE STANDARD SPECIFICATIONS (MASS) FOR COMPONENT PARTS AND MATERIALS USED IN CONSTRUCTION OF
ON—SITE WASTEWATER DISPOSAL SYSTEMS AND ATTACHED PES SPECIAL PROVISIONS.
2. SCOPE OF WORK: INSTALL NEW 1250g S.T.E.P. TANK AND SOIL ABSORPTION SYSTEM. CONSTRUCT LANDSCAPE BERM
3. GROUNDWATER WAS OBSERVED AT A DEPTH OF 9.0 FEET BELOW EXISTING GRADE AS EVIDENCED BY THE SOIL TEST
HOLE. IF AN APPARENT WATER TABLE IS OBSERVED IN ANY OF THE EXCAVATIONS LESS THAN 9.0 FEET BELOW EXISTING
GRADE NOTIFY THE ENGINEER IMMEDIATELY.
PROVIDE MINIMUM 3' OF COVER
OR RIGID INSULATION
il'>" 0 DRAIN PIPE W/
/-1/8` HOLES 18" O.C.
,- FILTER FABRIC
/'DRAIN ROCK 6"
/ ABOVE PIPE INVERT
LO
FIE
3 0<<
OR
_1.0
mRIGID
f
O�
FC
DRAIN ROCK
GM/
FILTER FABRIC P
5.0
SM
Q
—9.01 17
R. 1.
a
SECTION
DOUBLE CLEAN OUT
GM
BERM
SWALE
� BERM
MIN MIN 0.5'
MIN
SWALE SECTION
Z
COPPER
Z
mRIGID
INSOLATION w
O�
FC
O
F
FILTER FABRIC P
QO
O
Q
¢
R. 1.
a
ZQ
DOUBLE CLEAN OUT
DV
DRAIN ROCK 6" ABOVE PIPE INV a
FS
FLOW SPLITTER
CL
BELOW FINISH GRADE
z
1Ya" 0 DRAIN PIPE W/
TI/'1
ORIGINAL GRADE
FG
FINISH GRADE
n
/8" HOLES 18" O.C.
1250 g S.T.E.P.
TANK (P)
DESIGN PARAMETERS
UPGRADE SEPTIC SYSTEM
NO. BEDROOM: 3 (450 gpd)
TANK SIZE: 1250g S.T.E.P.
PERC RATE = 3.1 MPI
SOIL RATING: 1.2 GPD/SF
AREA RCD: 375 SF
SYS. TYPE: WIDE TRENCH 3.0' E.D
RF: 0.58
MIN LENGTH: 43.5 LF
USE:
45 LF X 5' WIDE, 3.0' E.D., 4.0' TD
TOTAL AREA: 388 SF
TRENCH SEE DESIGN
PROFILE
LEGEND
W WATER LINE/
WELL RADIUS
— SS NEW SEPTIC
NOTES: PANNONE ENG SVC, LLC
FOR CONSTRUCTION P.O. BOX 100217 ANCHORAGE, AK 99510
PHONE (907) 272-8218 FAX (907) 272-8211
FIRE LAKE, LOT 3, TRACT E
SARA BENSON
18607 FISH HATCHERY ROAD
DESIGN DETAILS EAGLE RIVER, AK 99577
ABBREVIATIONS
CU
COPPER
DIP
DUCTILE IRON PIPE
TH
TEST HOLE
FC
FOUNDATION CLEAN OUT
T#
TANK CLEAN OUT NO.
C#
CLEAN OUT NO.
M#
MONITOR TUBE NO.
R. 1.
RIGID INSULATION
DCO
DOUBLE CLEAN OUT
DV
DIVERTER VALVE
FS
FLOW SPLITTER
BEG
BELOW FINISH GRADE
OG
ORIGINAL GRADE
FG
FINISH GRADE
TS&V
TOPSOIL & VEGETATE
OF. AQ1111 L T;1/2014
/2014
4 TH �* r� NTS
P.I.D. NO
INC
Steven R. Pannone,, . /PERMIT NO
IPF.•, CE 8149 .'�/� OSP141214
cAsl • . 111,��1?OFESSIGNP�" Sheet
2 OF 3
TEST HOLE 1
OR ORGANICS
2
3
4
GM/ ROCKY BROWN
5 SM SILTY SAND
SOILS LOG - PERCOLATION TEST
SLOPE
X
TH
SITEPLAN P� I
i 1
TH-1 I
3BR
HOUSE
V I Sf
WAS GROUND WATER
ENCOUNTERED? N
IF YES, AT WHAT
DEPTH?
DEPTH TO WATER AFTER
MONITORING? -9.0'
DATE: 611312014
I
I'
SLOPE
TH
X
READING HATE
CLOCK
NET TIME
6
NET DROP
1 616/14
7
---
5.73
8
10:05
9
9.03
3.30
10
10:05
---
5.73
GM
VERY SILTY
11
10 MIN
BLUISH
3.22
BOH
GRAVEL
12
5.73
SIDEWALLS
10:25
COLLAPSING
13
3.20
14
15
16
17
18
DATE PERFORMED: 616114
SOILS LOG - PERCOLATION TEST
SLOPE
X
TH
SITEPLAN P� I
i 1
TH-1 I
3BR
HOUSE
V I Sf
WAS GROUND WATER
ENCOUNTERED? N
IF YES, AT WHAT
DEPTH?
DEPTH TO WATER AFTER
MONITORING? -9.0'
DATE: 611312014
I
I'
SLOPE
TH
X
READING HATE
CLOCK
NET TIME
WATERTIME
LEVEL
READING
NET DROP
1 616/14
9:55
---
5.73
---
10:05
10 MIN
9.03
3.30
s
10:05
---
5.73
--
10:15
10 MIN
8.95
3.22
s
10:15
---
5.73
---
10:25
1 10 MIN
8.93
3.20
PEROLATION RATE 3.1(min/inch) PERC HOLE DIAMETER 6 inches
TEST RUN BETWEEN 4.5 FT AND 5.5 FT
COMMENTS: Test hole excavated by JR'S SEPTIC PUMPING. Pere hole was presoaked. Pere test ran for
at least 1 hour. Last 3 readings recorded.
PERFORMED BY: Steven R. Pannone, P.E. I CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE
WITH ALL STATE AND MUNICIPAL GUIDLINES IN EFFECT ON THE DATE OF THIS TEST.
NOTES: PANNONE ENG SVC LLC — of A ��� Date
FOR CONSTRUCTION P.O. BOX 100217 ANCHORAGE, AK 99510 O C� ' ' Cgs�ll 7/1/2014
PHONE (907) 272-8218 FAX (907) 272-8211 #1 r y*t'� Scale
NTS
�..... .I)..:.. �
FIRE LAKE, LOT 3, TRACT P.I.D. NO
E '•<�
`a--.�. J051-333-09
Steven R. •R. Pannone
SARA BENSON / 1W PERMIT No.
PF•, CE 8149 liw OSP141214
18607 FISH HATCHERY ROAD c
SOILS LOG EAGLE RIVER, AK 99577 +��Ii�HOESSIONN�� Sheet
OF 3
UMMPAUTY OF ANCHORAGE
Development Services Department ° Phone: 907-343-7904
On -Site Water & Wastewater Section - Fax: 907-343-7997
Certificate of On -Site Systems Approval Jan 151
a oa 1
Parcel I.D. 051-333-09 Expiration Date:
1. GENERAL INFORMATION
Complete legal description Fire Lake, Lot 3, Tract E
Location (site address) 18607 Fish Hatchery Rd.
Current property owner(s) Dennis & Sharon Anderson
Mailing address
Real_ estate agent
2. TYPE OF DWELLING:
0 Single Family (w/wo ADU)
❑ Duplex
❑ Multiple Dwellings (Single Family and/or Duplex)
3. NUMBER OF BEDROOMS: 3
Day:phone
Day,phone
4. TYPE OF WATER SUPPLY:
TYPE OF WASTEWATER DISPOSAL:
Private Well
0
Private Septic
0
Water Storage
❑
Holding Tank
❑
Community Well
❑
Community
❑
Public Water System
❑
Public Sewer:,,,
❑
Waiver request for: Distance:
Received by: �j_— Date: oo r3 -J
COSA to be released to the engineer, unless otherwise requested by the engineer.
COSA Fee$ JJ� _ �a 5� Waiver Fee $
Date of Payment to (ate ja (J� C� Date of Payment
Receipt Number (50 Receipt Number
COSA # �2() l0-1 7� Waiver #
p�
COVID-19
25% DiC(-r)i it,,, n ►—.
5. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures
outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or
wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated
herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and
inspection, the on-site water supply and/or wastewater disposal system is (are) in compliance with all applicable Municipal and State
codes, ordinances, and regulations in effect at the time of installation.
In conducting an adequacy test, I attempt to provide a thorough, conscientious engineering analysis of the system in accordance with MoA
COSA guidelines and regulations. The reported results describe the performance of the system under the conditions encountered at the time
of the test, and separation distances measured to readily identifiable features. The operational life of all wells and septic systems depend on
the focal soil condition, ground water levels that may fluctuate during the year, and.the water usage of the.family being served by.the system.
These conditions are outside the control of the evaluator of this system. All systems eventually fail and satisfactory test results do not
guarantee future performance of the system, nor do they guarantee that there are no hidden defects or encroachments. Therefore we cannot
provide any warranty for future performance, nor can we estimate remaining life of the system. The content of this report is for the sole
benefit of the owner listed above. Reliance on this report by another person is at their own risk. Pannone Engineering Services LLC highly
recommends buyers hire their own engineer to evaluate this report.
Name of Firm Pannone Engineering Services Phone (907) 745-8200
Address P.O. Box 1807 Palmer, AK 99645
Engineer's Printed Name Steven R. Pannone P.E. Date
C� OF AL,4�
� 'sem
6. DSD SIGNATURE
System #1 Approved for bedrooms Steven R. Pannone
CE 8149 .E
System #2 Approved for bedrooms
Disapproved
Conditional approval for bedrooms, with the following stipulations:
IN(�OF trr�r�,
WATFR AND
LWASTL PATER Z
P ��
J
Jll�Jl� 77N%
SEM�
By: 6Original Certificate Date: 3D oC da��
q,h0 u-2
Iof i5]�O�
The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the
representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is
not responsible for errors or omissions in the professional engineer's work.
7. ATTACHMENTS:
COSA Checklist X Nitrate Advisory
Septic System Advisory Arsenic Advisory
Well Flow Advisory Other
COSA Checklist blue sheet
Legal Description: Fire Lake L3 Tr E
If more than 1 septic system on lot: COSA Checklist # 1 of 1
A. WELL DATA
❑ Well log is filed with Onsite (or attached)
Date drilled Unknown
Total depth Unknown ft
Cased to Unknown ft
❑ Sanitary seal is functioning correctly
❑ Wires are properly protected
Casing height (above ground) 18+ in.
Date of flow test for COSA 6/5/2020
Static water level at beginning of test 26.1 ft.
Comments
B. TANK DATA
Age of tank(s) 6 years
Tank type/material ITE 11St-1
Measured operating fluid level in septic tank
❑ Standpipes/foundation cleanout per record drawing
Date of pumping 6/8/20
D. ABSORPTION FIELD DATA Shallow Trench / Mound
Which system tested (date installed) 8/1/2014
❑ ALL standpipes present per record drawing
Total measured depth from grade 5.16 ft (max)
Measured depth to pipe invert from grade ft (min)
❑ N/A — pressurized field
❑ Monitor t b t b tt f ff
Parcel ID: 051-333-09
Structure served by this system 1
Well production at time of test 4.94 gpm
Water storage tank volume gallons
Well disinfected for coliform test? ❑ Yes No
❑ Coliform bacteria is Negative
Nitrate mg/L ❑ Nitrate less than MRL (ND)
Arsenic ug/L ❑ Arsenic less than MRL (ND)
Collected by Pannone Engineering
Date of Sample 107812020
C. LIFT STATION
F0 Required maintenance completed
Age of lift station 6 years
Lift station material Steel
Comments:
Adequacy test date 6/5/2020
Results D✓ Pass For 3 bedrooms
Fluid depth prior to test 11/9 in
Water added 457 gal
New depth 12/12 in
u es go 0 0 U111 e ective. If not, state E
depth into effective lapsed time 40 min
IN Code -required soil cover over field
Final fluid depth 11/9 in
❑ System presoaked Absorption rate '450 gpd
(Required if vacant for greater than 30 days prior to Any rejuvenation treatment (past 12 months) _
date of test) If yes, enter date
Gallons introduced gallons
Comments/Deficiencies:
COSA Checklist yellow sheet
E. SEPARATION DISTANCES
From Private Well on Lot to: (Please enter distances if less than required or if community well)
Septic Tank/Lift Station on Lot > 100'
Yes
if No 5+
Community Sewer Manhole/Cleanout > 100'
M✓ Yes
if No
ft
✓Cl' Yes
if No ft
Neighboring Tank > 100' Q✓ Yes
if No
ft
Private Sewer/Septic Line > 25' F71 Yes
if No ft
Absorption Field on Lot > 100' 0 Yes
if No
ft
Holding Tank > 100' P] Yes
if No ft
Neighboring Absorption Fields > 100'
Private Wells > 100'
0 Yes
Animal Containment > 50' F/I Yes
if No ft
M Yes
if No
ft
ft
Community Wells > 200'
0 Yes
if No ft
Water Service Line > 10'✓❑
Manure/Animal Excreta Storage > 100'
Yes
Community Sewer Main > 75' M/ Yes
if No
ft
R Yes
if No ft
From Septic/Holding Tank on Lot to: (Please enter distances if less than required)
Building Foundations > 10'
Yes
if No 5+
ft
Surface Water > 100'
❑ Yes
if No 75 ft
Property Line > 5'
Q
Yes
if No
ft
Wells on Adjacent Lots:
if No
ft
Absorption Field > 5'
Surface Water > 100' ❑ Yes
Yes
if No
ft
Private Wells > 100'
0 Yes
if No ft
Water Main > 10'✓Q
* Waiver on file - OSP141215
Yes
if No
ft
Community Wells > 200'
0 Yes
if No ft
Water Service Line > 10'✓❑
Yes
if No
ft
If septic tank is under driveway comment below
From Absorption Field on Lot to: (Please enter distances if less than required)
Building Foundation > 10' Yes
if No
ft
If absorption field is under driveway comment below
Property Line > 10' Q Yes
if No
ft
Wells on Adjacent Lots:
Water Main > 10' Q Yes
if No
ft
Private Wells > 100' Yes if No
Water Service Line > 10' 0 Yes
if No
ft
Community Wells > 200' Q✓ Yes if No
Surface Water > 100' ❑ Yes
if No 50*
ft
F. ENGINEER'S COMMENTS
* Waiver on file - OSP141215
2014 Landscape berm is still present
G. ENGINEER'S CERTIFICATION OF A, -Vlk
certify that i have determined through field inspections and review
of Municipal records that the above systems are in conformance with
MOA COSA guidelines in effect on this date.
62Z�- A, --
Steven R.Pannone
Cc 8149 \�
%POFESS��Aw
COSA Checklist yellow sheet
ft
ft
MUNICIPALI-11-Y
Development Services Department r` Phone: 007-33-7904
On -Site Water & Wastewater Section Fax; 907-343-7997
Lift Station/Pump Vault
K -
�.
Owner. � A-"- - :.�,��, .�.Street Address
Sec Tank:
Sludge level inches Pumping: required e - n -Pumping completed e no
Lift station:
-Pump basket cleane no Effluent filter cleanede -no
-Control floats cleaned �e no ¢Proper float settings confirmed o
Operation satisfactory es no
alarm §ystem:
}
Dedicated electrical alarm circ ' e�) no Audible 'nd_uL-ua. r i side dwelling yew no
_v
te—sto [y•Afar- system o eraon satisfactoryrct sanac0 lcl
•�c_ r c :
Manhole Riser
Ground water intrusion at riser to tank connection es nra
-Ground water intrusion around pipe penetrations
e n -Weep hole functional es) no
-Manhole lid: Functiona esj no Insulate es , o Properly Secured a no
Other
-All manufacturer required inspections and maintenance complet , e no
Comments:
Qualified Maintenance Provider:
Technician Date of maintenance
Company j
Signature Date
UBMITTA
• Municipality o Andforsge14
On -Site Water and Wastewater Program
(907)343-7904
Certificate of On -Site Systems Approval
Parcel I.D. 051-333-09
1. GENERAL INFORMATION
Expiration Date: / o >/S_'
Complete legal description Fire Lake, Lot 3, Tract E
Location (site address) 18607 Fish Hatchery Rd.
Current Property owner(s) Sara Benson Day phone
Mailing address
Real Estate Agent
18607 Fish Hatchery Rd.
2. TYPE OF DWELLING:
Fx1 Single Family (w/wo ADU)
❑ Duplex
❑ Multiple Dwellings (Single Family and/or Duplex)
3. NUMBER OF BEDROOMS: 3
Day phone
4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL:
Individual Well 17.1 Individual
Individual Water Storage ❑ Holding Tank ❑
Community Class Well ❑ Community ❑
Public Water System ❑ Public Sewer ❑
WaiverNariance request for. Distance:
Received by: Date: D 6t
COSA to be released to the engineer, unle otherwise requested by the engineer.
COSA Fee $
Date of Payment (0) $ lig( L1�`vv
Receipt Number D\ics �
COSA# bb(, 141535
Waiver Fee $
Date of Payment
Receipt Number
A0=_ .3
5. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation,
based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application,
shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate
for the number of bedrooms and type of structure indicated herein. I further verify that based on the information
obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water
supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes,
ordinances, and regulations in effect at the time of installation.
Name of Firm Pannone Engineering Services LLC
Address P.O. Box 100217, Anchorage Ak. 99510
Engineer's Printed Name Steven R Pannone
6. DSD SIGNATURE
Az System #1 Approved for bedrooms
System #2 Approved for bedrooms
Disapproved
Phone (907) 272-8218
Date 1/15/2014
Conditional approval for bedrooms, with the following stipulations:
By: Original Certificate Date: ® ! S 7
The Municipality of An age Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only
upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality
of Anchorage is not responsible for errors or omissions in the professional engineer's work.
7. ATTACHMENTS:
COSA Checklist X Nitrate Advisory
Septic System Advisory Arsenic Advisory
Well Flow Advisory Other
COSAbluesheM r'- .,
If more than 1 septic system is on the lot:
COSA Checklist # + of
Structure served by this system 1
Certificate of On -Site Systems Approval Checklist
Legal Description: Fire Lake, Lot 3, Tract E Parcel ID: 051-333-09
A. WELL DATA
Well type Private If A, B, or C provide PWSID #
Date completed Unknown Sanitary seal (Y/N) Y
Total depth Unk ft. Cased to Unk ft.
FROM WELL LOG
Date of test Unknown
Static water level Unknown ft.
Well production
Unknown
9 -
p.m -
Well Log (Y/N) N
Wires properly protected (Y/N) Y
Casing height (above ground) 18+ in.
AT INSPECTION
1/14/2014
28 ft.
4.2+ g.p.m.
WATER SAMPLE RESULTS:
Coliform Neg colonies/100 mL Nitrate ND mg/L
Arsenic ND ug/L Date of sample: 9/5/2014 Collected by: PES
B. SEPTIC/HOLDING TANK DATA
Tank Type/Material S.T.E.P/Steel
Tank size 1,250 gal. Number of Compartments 2
Foundation cleanout (YIN) Y
Date of pumping New
Depression over tank (Y/N) N
Pumper
Date installed 8/1/2014
Cleanouts(Y/N) Y
High water alarm (Y/N) Y
C. ABSORPTION FIELD DATA
Date installed $/1/2014 Soil rating (g.p.d./ft2 orft2/bdrm) 1.2 GPD/SF System type Wide Trench
Length 45 ft. Width 5 ft. Gravel below pipe 3 ft.
Total depth 5 ft. Eff. absorption area 388 ft2 Monitoring tube Y Depression over field N
Date of adequacy test New Results (Pass/Fail) PASS For 3 bedrooms
Fluid depth in absorption field before test New in. Water added New gal. New depth New in.
Elapsed Time: New min. Final fluid depth New in. Absorption rate >= 450+ g.p.d.
Any rejuvenation treatment (past 12 mo.) (Y/N & type) No If yes, give date
D. LIFT STATION
Date installed 8/1/2014
"Pump on" level at 43 in
Datum Bottom of Tank
E. SEPARATION DISTANCES
WELL ON LOT TO:
Size in gallons 250
"Pump off"level at 40
Cycles tested New
Septic tank/lift station on lot 100+
Absorption field on lot 100+
Public sewer main 75+
Sewer /septic service line 25+
Animal containment areas 50+
in.
Manhole/Access (Y/N) Y
High water alarm level at 45
Meets alarm & circuit requirements? Yes
On adjacent lots 100+
On adjacent lots 100+
Public sewer manhole/cleanout 100+
Holding tank 100+
Manure/animal excrete storage areas 100+
SEPTIC/HOLDING TANK ON LOT TO:
Building foundation 5+ Property line 5+
Water main 10+ Water service line 10+
Wells on adjacent lots 100+
ABSORPTION FIELD ON LOT TO:
Property line 10+ Building foundation 10+
Water Service line + Surface water 50
Curtain drain 50+ Wells on adjacent lots 100+
F. COMMENTS
* WR# OSP141215
G. ENGINEER'S CERTIFICATION
l certify that t have determined through field inspections and
review of Municipal records that the above systems are in
conformance with MOA COSA guidelines in effect on this date.
Engineer's Printed Name Steven R. Pannone
Date 10/6/2014
COSA brown sheet -1 0-10-1 2.doc
Absorption field 5+
Surface water 100+
Water main 10+
Driveway, parking/vehicle storage 100+
in.
o
n �•\ Ypy� S
1
ASBUILT
� u'zya.�ilLJ
Wh�"7
�Ycr� 0 oz's/B'z - Lo CJ
I HEREBY CERTIFY THAT I HAVE SURVEYED THE
FOLLOWING DESCRIBED PROPERTY:
AN; THAT NO ENCROACHMENTS EXIST EXCEPT AS
INDICATED. IT IS THE RESPONSIBILITY OF THE
OWNER TO DETERMINE THE EXISTENCE OF ANY
EASEMENTS, COVENANTS, OR RESTRICTIONS
WHICH DO NOT APPEAR ON THE RECORDED SUBDI-
VISION PLAT. UNDER NO CIRCUMSTANCES SHOULD
ANY DATA HEREON BE USED FOR CONSTRUCTION
OF FENCE LINES, OR FOR ESTABLISHING BOUND-
ARY LINES.
o
cccran
SCALE:
"yo
OATE-
9/�i
:9
GRI ��riS.s'S�
FS.
�3y-6z
DRAWN
0
,6o%'Qa vk
OF.AZ,4 °►
r ' Duane Mtrk Seward a