HomeMy WebLinkAboutT15N R1W SEC 4 LT 4 N2 NW4T15N RIW
ec. 4
Lot 4 N2 NW4
#051-043-57
Municipality of Anchorage
On -Site Water and Wastewater Program • (907) 343-7904
ON-SITE WASTEWATER INSPECTION REPORT 'J
Permit Number: Q S PZ 512 83. PID Number: C) Q4Z3 57
Dwelling: [Single Family (SF) ❑ Duplex (D) ❑ Multiple (SF and/or D) Project:New ❑ Upgrade
Name:
EAff f iC
ABSORPTION FIELD
❑ Deep Trench ,Shallow Trench El Bed ❑ Mound
Address
�� (� 7 I %
❑ Other
Phone c / p
Number of Bedrooms
Soil Rating
Total depth from original grade
GPD/SF
„S Ft.
LEGAL DESCRIPTION
Depth to pipe invert from original grade
3, Ft.
Gravel depth beneath pipe
14 Ft.
Subdivision Block Lot
Fill added above original grade
Gravel length
Township
Range Section
/\. Ft,
Ft.
Gravel width
S
Beds: Number of Lines
Distance between lines
SEPARATION DISTANCES (IV Z/Vw
Ft.
--
— Ft.
To
Septic Absorption
Lift Station
Holding
Sewer.
Total absorption area
Number of trenches
Dist. between tFenches
From
Tank Field
Tank
Line
430 Fe
— Ft.
Well
— .-
TANK 5Septic ❑ S.T.E.P. ❑ Holding ❑ Other
Manufacturer
1.
Capacity
Gal.
Surface Water/
%�0 f
_-
Material
Number of compartments
Lot Line
NA.
Foundation
2-0 ZLO ��
_
_
LIFT STATION
Manufacturer
Capacity
Gal.
Curtain Drain
SU r So ,
Remarks n ��
Pump on level at
in.
Pump off level at
in.
High water alarm at
in.
d �► D
Pump make and model
Electrical Inspections performed by
Installer
PIPE MATERIAL House to tankTank to
bJa3cf drainfield D30
rY, C
Drainfield a CO/MT��ji�
Inspector ^ y/ c`(w q
BENCH MARK (Assumed elevation) Q Q ft
�,
Inspection 1Q (5 2"d 4G , S
dates:
3rd 4m
Location and description
4�) rK
COMMUNITY DEVELOPMENT DEPARTMENT APPROVAL
Engineer's Stamp
I G
0
Conditional Approval: Date
_ F� -a��� °:
0`.Q CSS
°°,',���adti���,�. �.
Approved `�.C�R.
l �1U Date 1/��L,9_,�
�T�;r��n�: s
In on4inn Der,nrF n1 d0 A....
NOR THRIM
ENGINEERING
PO Box 770724
Eagle River, Alaska 99577
907.694. 7028
KNIK VISTA ST
Water
STl
A
26
B
54
ST2
32
58
DCO
35
60
C❑1
39
62
MT/CO
81
94
NOR THRIM
ENGINEERING
PO Box 770724
Eagle River, Alaska 99577
907.694. 7028
KNIK VISTA ST
Water
Valve
Key Box
1
I
-P
1 C
voe
£
Alternate Trench\ MT/CO
01
1 Ln
f"
W
Y/ TH
1
New 1000 Gallon
DC ❑❑11
c
Septic Tank
Sit
J
I
m
c
0
House Sits On A
�i
1 U
u
Raised Knoll
8dr�
1 )
M
Barn
I
1
1
d
/
1 3
sy
N
i
A
1
T15N R1W SEC 4
LOT 4 N2 NW4
WASTEWATER RECORD
PUBLIC WATER
1" = 100'
RECORD
LAYOUT
12/27/1812 of 3
C
u
c
F-
06
y
c
C5
I --
-U
-P
n
LA
4->
:5
0
c
C5
-a,
�Lj U
00 0)
co Ul
0
Cdl QL
0 (1
-P m
0 C5
;p >
C5 -2�
> Ljj
Qj
1-d
In
:3
0
C- oj
w
C3 73
ad
u
y
LL
-C
u
c
0i
C4-
0
0
CL
I
75
c-
LLI
0
I--
0
-P
IW
-Q
Z:f d
00
W
z
0
L3
d
c
0
06
C5
c
LL -
flu!
CD
00
0
:p
A
A
M
I
Lr?
Ln
o Ln
:p
d
>
LLJ
d
0
L
LD
0
z
CD
CJ
0
-P
d
oi
L.1
k
cv Y
0
F—
Ln
>
co
c
0
LLJ
I
U
@i
u
III
ry
n
0
c-
0 CT0
Li
L0 L- W
-
-P
C:) u
C:) C
u
d
c) <
0
>
--4
n
0i
LLL
0
-P
IW
-Q
Z:f d
00
W
z
0
L3
d
c
0
06
C5
c
LL -
flu!
CD
00
0
:p
A
A
M
I
Lr?
Ln
o Ln
:p
d
>
LLJ
d
0
L
LD
0
z
CD
CJ
0
-P
d
oi
3 W
L.1
0
Ln
LLJ
I
Cy
1--1
W
u
3 W
L.1
Ln
LLJ
I
Cy
1--1
W
u
III
ry
n
\Y/
W
Li
u
W
W
ry
n
r)
LLL
Oj
00)
C�
CL
Lu
Z
On -Site Wastewater Disposal System Permit
MUNICIPALITY OF ANCHORAGE
Development Services Department
On -Site Water & Wastewater Program
4700 Elmore Road, PO Box 196650
Anchorage, AK 99519-6650
Telephone: (907) 343-7904
Permit Number: OSP151283
Tax Code Number: 05104357000
Work Type: Septic Renewal
Permit Effective Dates: October 08, 2015 to October 07, 2016
Design Engineer: NORTH RIM ENGINEERING
Subdivision: T1 5N R1W SEC 4
Site Legal Address: T15N R1 W SEC 4 LT 4 N2 NW4 G:1558
Owner/Address: BARKER JOEL & YVETTE
PO BOX 672167 CHUGIAK AK 995672167
Site Mailing Address: 21720 RANKIN RD, Chugiak
This permit is for the construction of:
Y Disposal Field Y Septic Tank N Holding Tank N Privy
/�5�i� 1><,
Lot Size in Sq Ft: 217800
Total Bedrooms: 3
N Private Well N Water Storage
All construction must be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater
Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80).
3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services
Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either:
A. Open and Close on the same day.
B. Covered, sealed, and heated to prevent freezing.
451
Received By:
Issued By:/'(� ��t/ /C/ Date: O S
i
1->
(e
Community Development Department t.� Phone: 907-343-7904
Development Services Division Fax: 907-343-7997
On -Site Water & Wastewater Program
ON-SITE SEWERANELL PERMIT APPLICATION
R JSH!
Parcel I.D. 0 S/ U 3 5- 7
Property owner(s) 6A& 111%E(p. Day phone
Mailing address opo CX 6'72/6' 7
Site address C ar /24
Legal description (Sub'd., Block & Lot)
Legal description (Township, Range & Section) T/,5A/ &/ V/ "_'7— SL NZ GVW c f
Lot Size 2J 7 Sf Qd Sq. Ft.
APPLICATION IS FOR:
(® all that apply)
Absorption Field
Septic Tank
Holding Tank
❑
Privy
❑
Private Well
❑
Water Storage
❑
Number of Bedrooms 3
APPLICATION IS AN: TYPE OF DWELLING:
Initial Single Family (SF)
�❑ (w/woADU)
Upgrade
Duplex (D)
❑
Renewal
Multiple Dwellings
❑
(SF and/or D)
THIS APPLICATION INCLUDES A VARIANCE i WAIVER REQUEST FOR:
Distance:
I certify that the above information is correct. I further certify that this is in accordance with
applicable Municipal Codes.
No
Permit/Rush Fees: IG •.Bina/ Waiver Fees:
Date of Payment: Q Date of Payment:
Receipt Number:Receipt Number:
Permit No. _ Waiver No.
05P 15 /z93
Permit App_9-1-12.doc
On -Site Wastewater Disposal System Permit
MUNICIPALITY OF ANCHORAGE
Development Services Department
On -Site Water & Wastewater Program
4700 Elmore Road, PO Box 196650
Anchorage, AK 99519-6650
Telephone: (907) 343-7904
Permit Number: OSP141227
Tax Code Number: 05104357000
Work Type: Septic Initial
Permit Effective Dates: July 09, 2014 to July 09, 2015
Design Engineer: NORTH RIM ENG
Subdivision: T1 5N R1W SEC 4
Site Legal Address: T15N R1W SEC 4 LT 4 N2 NW4 G:1558
Owner/Address: BARKER JOEL & YVETTE
PO BOX 672167 CHUGIAKAK 995672167
Site Mailing Address: Lot Size in Sq Ft: 217800
Total Bedrooms: 3
This permit is for the construction of:
Y Disposal Field Y Septic Tank N Holding Tank N Privy N Private Well N Water Storage
All construction must be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater
Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80).
3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services
Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either:
A. Open and Close on the same day.
B. Covered, sealed, and heated to prevent freezing.
Received
Issued By:
By: Date:
Date: ! y
MUNICIPALITY OF
Community Development Department
Development Services Division 00*_�
On -Site Water & Wastewater Program
ANCHORAGE
Phone: 907-343-7904
Fax: 907-343-7997
ON-SITE SEWER/WELL PERMIT APPLICATION
Parcel I.D. O 5 7
Property owner(s) TO L Aft Its 2 Day phone 4< 00 6��6
Mailing address.. P Q 6010 6 r(21 6 7 { e H t)6 1A K. 9 9 5 6 7
Site address 44H
Legal description (Sub'd., Block & Lot) T/ S N' R / in/ S Ee L,/ L O!
Legal description (Township, Range & Section)
Lot Size 217 J00 Sq. Ft. Number of Bedrooms
APPLICATION IS FOR:
(0 all that apply)
APPLICATION IS AN:
TYPE OF DWELLING:
Absorption Field
Initial
Single Family (SF)
;R1
Septic Tank
Qt
Upgrade ❑
(w/wo ADU)
Duplex (D)
❑
Holding Tank
Li
Renewal
Privy❑
SLF8MiTiWt
DwellingsEland/or D)
Private Well
❑
Water Storage
❑
JUN 2 5
2014
THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR:
Distance:
I certify that the above information is correct. I further certify that this is in accordance with
applicable Municipal Codes.
i
ur autrlorizea
Permit/Rush Fees: cJ Waiver Fees:
Date of Payment: / Date of Payment:
Receipt Number: [54YrA_ Receipt Number:
Permit No. 05 191 Ll II&I Waiver No.
Permit App_9-1-12.doe
Nwy
TH 12 M
ENGINEERING MEMO
Steve Eng, PE, PH
P.O. Box 770724, Eagle River AK 99577
(907) 694-7028 tel
northrimeng@aol.com
Date: 7/8/14 Number of Pages:
To: MOA On -Site Services
Subject: T15N R1W Section 4 Lot 4 N2 NW4
New Septic System
A new house is planned for the subject lot. A new soil test was completed, sandy soil and no
groundwater. The design calls for a 5' wide trench with new septic tank. The entire subdivision is
on public water and septic systems. The terrain slope is near flat, except for the house site which
sits on a raised knoll. This is a large lot at 5 acres.
Please review the wastewater system design for the new single family home. I have included
design plans & specs, design guidelines, & soil tests. If there is need for additional information or
clarification please give me a call.
Thanks -Steve
,Yy mape =a m..a pmt vQ
aA �sRq
.�6 a•W mm ma Saab m 'i
N i
Gt mipiCi6E1e'•5
TH, IZJ ` e Steven V!. 9
ENGINEERING "�a ' cae� 4�-��"� 15N Rl W, Section 4, Lot 4 ND N W'/V
SPECIFICATIOI iCr L1�;SIGN GUIDELINES —
Wastewater System Sizing:
This is a new 3 -bedroom, single family home. This is a very large lot in a developed
neighborhood. This is a 5 acre lot with no conflicts due to the large size. No adverse
impacts are expected from development. No conflicts to the other lots will take place by
this septic system construction. Public water serves the area lots and this lot. The
easements are located on the drawing and are not encroached upon. Soil tests revealed
sandy soil with low silt. An application rate of 1.2 GPD/FTz with 0.5 reduction factor for
utilizing a 5' wide trench. Trench Length = 375 FT2/5'x .5 reduction factor = 37.5'; 1 line
@ 40'. No bedrock was encountered or groundwater was encountered.
Specification Requirements: All components and work must comply with the
Municipality of Anchorage Specifications (AMC) & State of Alaska Drinking Water
Regulations and Wastewater Regulations.
• Two compartment, 1000 gallon septic tank. Watertight couplings on inlet & outlet.
• 5' minimum between the tank and bed. 10' to property lines.
• 3' of cover or insulation is required for trench; an equivalent of 1" insulation for 1'
soil cover may be used. 2" Minimum thickness for insulation.
• Backfill over drain rock must not be less than 24", with the 2" insulation.
• Tank & solid pipe must be set on well compacted, stable soil.
• 4 inch diameter cleanouts with airtight caps are required 1' to 4' from foundation
wall, prior to any 90 degree bend in 4 inch line, in each tank compartment, and two
adjacent opposing cleanouts between the tank and the absorption field, not more than
10' from the tank positioned to provide cleanout access towards the tank and towards
the absorption field.
• All cleanouts must extend to at least ground level.
• In solid pipe runs, ASTM D-3034 may be used in lieu of cast iron.
• Trench to be placed level, minimum of 4' to groundwater, 6' to bedrock from drain -
rock.
• Drain rock to be 1/2" to 2 %z" screened. Drain rock to be distributed uniformly
throughout the trench.
• Perforated pipe to be installed level with perforations down.
• Silt barrier (filter fabric) to be installed above the drain rock.
• Smeared trench sides must be raked or scarified before drain rock placement.
• The finish grade must be mounded to promote drainage away from trench.
• Insulation must be placed over any pipe installed under driveways or parking areas.
• Approved pipe materials include cast iron, PVC ASTM D3034, PVC ASTM F789,
ABS ASTM D2661,
• Sewer Service Line is minimum 2% slope.
• Septic Tank to be pumped every two years or when required.
• Insulation board to be extruded direct burial polystyrene (Dow Styrofoam HI/equal)
DESIGN NOTES:
1. Total Depth of Trench is 7.5'.
Terrain Slopes Northwest.
2. Sewer Service Line minimum 2% slope.
3. Public Water.
NOR THRIM
ENGINEERING
PO Box 770,724
Eagle River, Alaska 99577
907.694.7028
KNIK VISTA ST
-k.`.q' T15N R1W SEC 4
asm LUT 4 N2 NW4
� .7�.........
aq t
®..fCry
�� WASTEWATER DESIGN
PUBLIC WATER
1" = 100'
PLAN
LAYOUT
tee: � ______
7/8/14 2 of 3
Key Box Water
Valve/
/
4�
/
I+
v
e
Alternate Trench
N
C
W
�4
or
New Trench
c
MT/CD
TH
C
D
0
Double CD's
u
New 1000 Gallon
v
I N
Septic Tank
3 Bdrm House
ro
Barn
House
Sits On A
Raised
Knoll
a
3
d
i
A
-k.`.q' T15N R1W SEC 4
asm LUT 4 N2 NW4
� .7�.........
aq t
®..fCry
�� WASTEWATER DESIGN
PUBLIC WATER
1" = 100'
PLAN
LAYOUT
tee: � ______
7/8/14 2 of 3
S
u
c
QjL
F-
06 06
Y
i
C5
H
U_
a
v
N
v
3
w
N
pq
LA
5
O
d
d
N
U
O)
O
a
a
0
�-E
i'
3
O
i
C5
a,
U
i
O
v
C5
75
c
O
L,
t
N O
N
�Z
it U
M
d
F
!o
aj 4
oa
O
H
LO
d
�L
LO
� W
O
a
CO
CO
z
v
O
o
R
0
H
N
E
uu
1 cm)
z
W
3 -i
I
N
�Z
it U
W
�
o
!o
aj 4
oa
rn
��
W
(no
�I
d
�L
LO
� W
a
CO
CO
v
R
N
uu
N
W
d
M
O
0
F
�
N
+' i Ol
U W Cl)
C5 > d
CL O i
O U
U U
i
O
N O
u 0 T
a
d U t
aia
-P d
V F a
Lcu a
v
�~
s� �c
O
EO m
0 3 £ -iO-`
d
a L
Pq E
O
(T
S
U
U7 a E
LL
Waj
o uf
o IriO
UL
UO) E
v
o
o¢
nay-�L a
a
aL4�
a a, L
u v J O O i d5
O
W N U U Ul
aj U d
--
Vl
F- i 0 i s H
W
d0 ai �u E
~
EO
Z
a,0)1 ai 0)
S U:6 L LM O-5
ao-p3aa,3aa,
�
n3v�a�
W
p
-4 (U (`'l 4 In �6
W
3 -i
I
N
�Z
Ua
3
W
�
o
!o
��I
?
oa
rn
��
W
(no
�I
V
LO
� W
o
CO
CO
W
3 -i
O n
� h
�Z
Ua
3
W
o
N
��I
?
oa
rn
��
W
(no
�I
m
Z
� W
S❑ILS LOG — PERC❑LATI❑N TEST
prrTH IR MINEERING
Performed For: Joel Bar
Legal Descriptions
DEPTH
(FEET)
1 -
Date
Gross Time
2
Depth
lNet Drop
3
-
0
4
-
--
5
-
10
10 min.
10,5"
5,0"
3
8/21
12
--
5,5"
--
9
-
22
10
10.5"
5,0"
11 -
8/21
25
12 -
5.5"
--
13
8/21
35
14 -
10,5"
5,0"
7
8/21
15 -
--
5,5"
16 -
8
8/21
17 -
10 min,
10.5"
18 -
9
8/21
19 -
--
5.5"
20 -
10
8/21
Organic
Date Performed: 8/16/12
TISN RIW See.'{
SP
Sand w/ Gravel
4 Na NW4 tgrs.e.
T.H, Location: Directed By
Joel Barker- End Of Knik Vista
Groundwater? No
Depth --
Water Depth
After Monitorino None Date: 8/25/12
#
Date
Gross Time
Net Time
Depth
lNet Drop
1
8/21
0
--
5.5"
--
2
8/21
10
10 min.
10,5"
5,0"
3
8/21
12
--
5,5"
--
4
8/21
22
10 min,
10.5"
5,0"
5
8/21
25
--
5.5"
--
6
8/21
35
10 min,
10,5"
5,0"
7
8/21
37
--
5,5"
--
8
8/21
47
10 min,
10.5"
5.0"
9
8/21
50
--
5.5"
--
10
8/21
60
10 min.
10,5"
5.0"
21 - Percolation Rate 2 min./inch Perc Hole Diameter 6"
Test Run Between 3' and 4'
Comments "
Performed By NorthRim Fng. I CERTIFY THAT THIS TEST WAS
Performed in Accordance with All State/Municipal Guidelines in Effect
ON THIS DATE. DATE1 8/21/12
OF
NORTHRIM
ENGINEERING *:asm' TESTH❑LE LOG T, H. 1
....
Po Box .7028 /� " GE❑TECHNICAL
E*9le Rlva4 Alaska 99577 a
907.894.7028 E.t 1�
8/21/12 11