Loading...
HomeMy WebLinkAboutHORIZON ESTATES LT 6Horizon Estates Lot 6 #051-324-26 Municipality of Anchorage On-Site Water and Wastewater Program • (907) 343-7904 Page of ON-SITE WASTEWATER INSPECTION REPORT Permit Number: OSP141336 PID Number: 051-324-26 Dwelling: N Single Family (SF) ❑ Duplex (D) ❑ Multiple (SF and/or D) Project: 0 New ❑ Upgrade Name: Troy Davis Homes ABSORPTION FIELD X Deep Trench ❑ Shallow Trench ❑ Bed ❑ Mound Address 165 E. Parks Hwy #200 Wasilla, AK 99654 ❑ Other Phone Number of Bedrooms Soil Rating Total depth from original grade 357-9394 4 .g GPDfSF 11.5 Ft. LEGAL DESCRIPTION Depth to pipe invert from original grade 3.5 Ft.8 Gravel depth beneath pipe Subdivision Block Lot Horizon Estates 6 Ft. Fill added above original grade . 0-1 Ft Gravel length Ft. Township Range Section Gravel width 3 Ft. Beds: Number of Lines Distance between lines I Ft SEPARATION DISTANCES To Septic Absorption Lift Station Holding Sewer Total absorption area Number of trenches Dist. between trenches From Tank Field Tank Line 7552 Ftp 1 Ft. Well >100' >100' >100' NA >25' TANK IN Septic ❑ S.T.E.P. ❑ Holding ❑ Other Manufacturer Anchorage Tank Capacity 1,250 Gal. Surface Water >100' >100' >100' NA Material Number of compartments Lot Line >5' >10' >5' NA Steel TWO NA Foundation >5' >10' >5' NA LIFT STATION Manufacturer Capacity Curtain Drain None Noted Gal. Remarks Pump on level at in. Pump off level at in. High water alarm at in. Pump make and model Electrical Inspections performed by Installer PIPE MATERIAL House to tank D3034 dra nfield D3034 Northern Excavation Drainfiele 63034 CO/MT 171,3034 Inspector A. Harala BENCH MARK (Assumed elevation) 102.45 1t Inspection ection f9' 9/21/14 9/21/14 Location and description Zm 3'a 10/5/14 4�^ Garage Slab. COMMUNITY DEVELOPMENT DEPARTMENT APPROVAL .OF ..... t Conditional Approval: Date_7A 49LHH b s................. .........., ;MICHAEL E. ANDERSON �•� R� ��.•• CE-4381 ; \�`�s ApprovedJj4L4/Date �111S s''�.• Municipality of Anchorage DEVEOPMENT SERVICES DEPARTMENT 4700 South Bragaw Street Anchorage, AK. 99519-6655 - 343-7904 Permit Number: OSP14336 \ \eeMT1S° HORIZON ESTATES LOT 6 40,028 SF Page 2 of 3 PID No. 051-324-26 Z Alternate LEGEND A=' P' '• :� '' Site Ml — — Monitor Tube o ♦ r ♦ ; w - 146.75 FCO —Foundation Clean Out LOT 5 w M' c5 Test Hole LOT 7 C3 C1 — TH6A o � � £ C -ly S2 Wo S2 19.6' 27.0' �D 00 St p C4 25.8' 28.4' C5 55.9' 39.3' UI ° rT M7 55.9' 39.5' /. no FCO � v / FOUR BEDROOM HOME fU Q' Well OF �O :> ' : 15' T & E ESMT. "'`' °' LEGEND A=' P' '• :� '' Ml — — Monitor Tube S89054'25"W ♦ r ♦ ; w - 146.75 FCO —Foundation Clean Out {=.r♦j ••°: TH — Test Hole 49th ♦ o :.......................... ✓.I...:...so ATTTT TlAOW CTl?Ti VT o C1 — Clean Out ............ _ IC MHAEL E. AN➢ERSON � '•y., No, CE -4381 z-75,... ' 1 Municipality of Anchorage Page 3 of 3 DEVEOPMENT SERVICES DEPARTMENT 4700 Elmore Road Anchorage, AK. 99519-6655 - 343-7904 On -Site Wastewater Disposal System or Well Inspection Report Permit Number: OSP141336 yo.i N Finished Ground 1,250 Gallon Septic Tank 93.65 PID No. 051-324-26 9-22-14 47' (Trench Length) PROFILE AS -BUILT - No Scale MUNICIPALITY OF ANCHORAGE DEVELOPMENT SERVICES DEPARTMENT 4700 BRAGAW STREET ANCHORAGE, AK 99519-6650 DEPTH (fee[) I- 2- 3 - 4- 5- 6- 7- 8- 9- 10- 11 SOILS LOG - PERCOLATION TEST LEGAL DESCRIPTION: LOT 6, HORIZON SUBDIVISION PERFORMED FOR: TROY DAMS HoMEs DATE: 9/15/14 PROJECT No.: PARCEL ID#: TECHNICIAN: A. HARALA v a d m TEST HOLE 6A OB/OG SILTY GRAVEL WITH SAND a GM fir• 49th ••`:'� MICHAEL E. ANDERSON No. CE -4381 SI I E FLAN SEE SITE PLAN WAS GROUND WATER ENCOUNTERED? NO IF YES @ WHAT DEPTH? DEPTH OF WATER AFTER MONITORING: NONE 2% DATE OF MONITORING: /22/14 p a 9 C 12-1 13 a DENSE 14 . 15 a 16 17 a 18 DATE READING GROSS TIME (MINUTES) NET TIME (MINUTES) DEPTH TO WATER (INCHES) NET DROP (INCHES) TEST HOLE PRESOAKED PRIOR TO TESTING: 9/15 1 2:12 1.25" 2 2:42 30 4.50" 3.25" 3 2:43 1.3811 4 3:13 30 4.63" 3.25" 5 3:14 1.25" 6 3:44 30 4.50" 3.25' PERCOLATION RATE: 9.2 (MIN/INCH) PERC. HOLE DIA.—6, , (INCHES) TEST RUN BETWEEN: 4.5 FT. and 5.5 FT. COMMENTS: TEST HOLE PRE SOAKED PRIOR TO TEST. TEST PERFORMED BY ANDERSON ENGINEERING. I, MICHAEL E. ANDERSON CERTIFY THAT THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPLE GUIDELINES IN EFFECT ON THIS DATE: 2/1/15 ACE WATER WELL DRILLING NG A subsidiary of ACE Ventures, Inc. P.O. Box 520090 1167 N. Knapp Dr Big Lake, Ak. 99652 (907) 357-7987 fax (907) 376-7987 (907) 354-1398 cell Well Owner Trop Davis Homes Use of Well: Domestic Location: Lot. 6 Horizon Estates - Eagle River Date of Completions 08/28/2014 Job # 14- 08 Drilling Method: Air Rotary SizeofCasing: 6" Depth.of hole: 145 feet Cased to: -344 Feet Static Water Level: 34 feet below top of casing. Finish of Well( X ) Open End ( ) Grout/Seal O Screen2iner { ) Perforated Describe screen, seal, or perforation: None Well Pumping Test at 40 Gallons per ( ) hour ( Y ) minute. Suggested Pump setting depth: 130 feet from top of casing. Method of disinfection: Chlorine tablets Depth in feet from casing to Details of Forniations/size/color/ etc 0 to 2 feet Stick u 2 to 133 feet Silty, clayey ayel 133 to 140 feet Water gravel 140 to 145 feet Bedrock Driller Signatures � '_ 7 — _.._ Date: r� / Ace dilater Mels P O Box 520090 Big Lake, Ak. 98632 (907)375-7987 aqeh2oj2rntaonNne. net Pump Installation Well owner: Troy Davis Homes Job# P14-08-1 Installation Date: 11/19/2014 Legal Description: Lot 6 Horizon Pump Intake Depth: 113' feet below top of casing (TOC). Pump Manufacturer: Goulds Well Depth: 145' Model: Bruiser Size: % Horse Static: 113' SIV: F1459386 GPM: 10 Pitless adapter buried depth: 12' Disinfection method: Chlorine tablets Additional comments: Water Sample Taken, Control Box leaning against the pressure tank. Installer signature: �_J m Date 1 ('-2-6 On -Site Water & Wastewater System Permit MUNICIPALITY OF ANCHORAGE Development Services Department On -Site Water & Wastewater Program 4700 Elmore Road, PO Box 196650 Anchorage, AK 99519-6650 Telephone: (907) 343-7904 Permit Number: OSP141336 Tax Code Number: 05132426000 Work Type: WellSeptic Initial Permit Effective Dates: August 19, 2014 to August 19, 2015 Design Engineer: ANDERSON ENGINEER Subdivision: HORIZON ESTATES Site Legal Address: HORIZON ESTATES LT 6 G:0553 Owner/Address: TROY DAVIS HOMES INC 165 E PARKS HIGHWAY STE 200 WASILLAAK 996540000 Site Mailing Address: 18273 MULDROW ST, Eagle River This permit is for the construction of: Y Disposal Field Y Septic Tank N Holding Tank All construction must be in accordance with: Lot Size in Sq Ft: 40049 Total Bedrooms: 3 N Privy Y Private Well N Water Storage 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80). 3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either: A. Open and Close on the same day. B. Covered, sealed, and heated to prevent freezing. The Engineer needs to do an additional test hole prior to the construction of the septic field. Construction may proceed at your own risk before the 7 day water monitoring is complete. Please submit stamped and signed results with the As -built Inspection Report. If the results require a design change, construction of the system will stop pending On -Site review and approval. Received Issued By, MUNICIPALITY OF ANCHORAGE Community Development Department / Phone: 907-343-7904 Development Services Division Fax: 907-343-7997 On -Site Water & Wastewater Program V . Parcell.D. ON-SITE SEWER/WELL PERMIT APPLICATION 051-324-26 Property owner(s) Troy Davis Homes Day phone 310-2501 Mailing address 165 E. Parks Highway #200 Wasilla, AK 99654 Site address Fish Hatchery Road Eagle River, AK 99577 Legal description (Sub'd., Block & Lot) Horizon Estates, Lot 6 Legal description (Township, Range & Section) Lot Size 40,049 Sq. Ft. Number of Bedrooms9 APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: I® all that apply) Absorption Field ❑X Initial ❑X Single Family (SF) ❑X Septic Tank ❑X Upgrade (w/wo ADU) pg ❑ Duplex (D) ❑ Holding Tank ElRenewal ElMultiple Dwellings ❑ Privy❑ �,/ ■ �� ®s and/or D) R Private Well 0 SH(rJ HL Water Storage El 18 2014 THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR: :.,,Distance' I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. 4a'--7 (Signature of property owner or authorized agent) 129=F,uo Permit/Rush Fees: 5(61,+ 2-11,5 f `lm,40 Date of Payment: $1 1 tf 614 Receipt Number: t�5t-2G�- Permit No. UD'PlLi 1-$:X, Permit App_-'.:. :-'.,:c; Waiver Fees: Date of Payment: Receipt Number: Waiver No. August 16, 2014 Municipality of Anchorage Development Services Department On -Site Water and Wastewater Program 4700 South Bragaw Street Anchorage, AK 99519-6650 Subject: Lot 6, Horizon Estates Subdivision Septic System Design and Permit Application Impacts to Adjacent Properties Dear Onsite Services Engineer: The owner of Lot 6, Horizon Estates Subdivision intends to construct a new four- bedroom home on the lot. We are requesting a permit be issued for the construction of a new well and septic system to accommodate the home. The attached Site Plan and backup documentation identify the location and configuration of the proposed well and septic system along with the alternate site. Also identified on the plans are the proposed and existing wells in the area and septic systems on surrounding lots. No conflicts exist between the proposed septic system and the well or septic systems and wells on adjacent lots. Drainage arrows and ground contours are shown on the site plan showing the grade and direction of flow on the lot. The drainage pattern will not be changed as a result of this project. The test holes placed on the lot indicated silty gravel with sand (GM). The percolation rate of the soil was determined to be 6 to 15 minutes per inch. No groundwater was found during the placement of the test holes and none was noted during the monitoring period. An application rate of .8 gallons per day per square foot was used in the design of the absorption system. We are proposing to place a new 1,250 -gallon septic tank and a 47' long by 3' wide by 8' effective depth absorption trench to treat and dispose of the effluent generated in the house. The elevation of the distribution line in the absorption trench will be 2.5' below the surface and the total depth will be 10.5'. A minimum of 3' of fill or 2" of insulation and 2' of fill will be placed over the absorption trench and 4' over the septic tank. The ground surface on the lot in the area of the septic system slopes to the north and northwest at a shallow grade with some cross sloping from the east. The new trenches will be constructed parallel with the contours of the slope as much as possible in conformance with Municipal requirements. The new septic system will be constructed a minimum of 100' from all wells and any surface water and 10' the proposed and existing water services in the area. Lot 6, Horizon Estates August 16, 2014 Page Two If the system is constructed in accordance with our design the following statements apply: 1. The system, if constructed as designed, will have no adverse impact on the wells in the area or those to be constructed in the future. 2. The system, if constructed as designed, will have no adverse impact on existing septic systems in the area or those to be constructed in the future. 3. The system, if constructed as designed, will have no adverse impact on reserve space, either surface or subsurface, on any lots located in the area. 4. The system, if constructed as designed, will have no adverse impact on drainage patterns in the area. The current drainage pattern will be maintained. Sincerely, Michael E. Anderson, P.E. Attachments t;K.' ._.. l?K .* MICHAEL E. ANDERSON No. CE -4381 o� Z I 0 J z a o> 0 0 J ioa z i Ilk r is • 'WNIgQwMAI (n o I N H / II1- \ 3- I\�L' L_LJ NIl W I alp P / ItT / ILi ns D � LC I 0 J z a o> 0 0 J ioa z i Ilk r is • 'WNIgQwMAI (n o I N H � : L'1"I N — O `n V/ m 3- I\�L' L_LJ II — � l alp °^ 1 / L'1"I N — O `n V/ m 3- I\�L' L_LJ II — � alp ns D � mJ� m I W c_ A y o� I J roe � 9 49 33 \ ro. \ HO ON ATES \ L 6 4 ,028 SF CDAlternate ` CD Sit. \\ CONTOU INTERVAL — CD proposed Co p 47' Long x 3' Wide O x 8' Effective Depth Absorption Trench O 5 MT Co C Sv 1,250 W D Ilan Septi CD Saptic ank SV � fufl '- FCO ® m FOUR B ROOM E N ZE .,-o, . • ` PropWeosed 15' & E ES T. S89° '25"W 1 .75 % O .• ""' •••.� •••0 ULDR W ST EET Ar e 49th !�V •`; LEGEND ,....:........................ SITE PLAN MT -Monitor Tube 10.. ................. FCO -foundation Clean Out t ' MICHAEL E. ANDERSON % TFI -Teat Hole ��t ,I CO - Clean Out SCALE 1" = 40' �.rf-ND. CE-4381 ti2C0 -Double Clean Out •� 4 p� ,...... • 30.00 30.00 LOT 6, HORIZON ESTATES SUBDIVISION DESIGN FACTORS: SYSTEM REQUIREMENTS: Four Bedroom Home Deep Trench System Perc. Rate: 6-15 Min./Inch 1,250 Gallon Septic Tank Application Rate: .8 GPD/SF 8' Drainfield Rock 4 Bedrooms X 150 GPD/.8 GPD/SF (Application Rate) = 750 SF Absorption Area 750 SF/16 SF/LF = 46.875 LF Trench Length THEREFORE: Construct a 47' Long x 3' Wide x 8' Effective Depth Absorption Trench at the Location Shown. Flow Line Elevation in the Trench to be 2.5' Below Original Ground. Total Depth to Be 10.5' Below Existing Ground. Provide 4' of Cover Over Septic Tank and a Minimum of 3' Cover Over Absorpiton Trenches. Maintain 100' Separation from Wells in the Area. Natural Backfill 2'0" Geotextile Fabric 6., O 4" Perforated PVC (Holes Down) 8'0" 1 1�— Drainfield Rock 3' TYPICAL DEEP TRENCH SECTION �.�w a zmio (NO SCALE) �.�p ................... NOTE: Grade Area Over Trench to Drain Away. ?a;' Minimum 6' Separation From Bedrock. : :: 49th Minimum 4' Separation From Groundwater. i �....................... Minimum 100' Separation From Wells in the Area. m, MICHAEL E. ANDERSON Minimum 100' Separation From Surface Water or Streams. No. CE49a, MUNICIPALITY OF ANCHORAGE DEVELOPMENT SERVICES DEPARTMENT 4700 BRAGAW STREET ANCHORAGE, AK 99519-6650 DEPTH (feet) 1- 2- 3- 4- 5- 6- 7- 8- 9 - SOILS LOG - PERCOLATION TEST LEGAL DESCRIPTION: LOT 6, HORIZON SUBDIVISION PERFORMED FOR: TRoy DAVIs HoMEs DATE: 10/9/13 PROJECT No.: PARCEL ID#: TECHNICIAN: A. HARALA OB/OG a d d TEST HOLE 5 SILTY GRAVEL WITH SAND d GM 11 0 12- 13-. 14- 15- 4 4 15d 16- 17- 18- SLOPE 61718 SLOPE wc,: - 1. V .`- 49th _2 SEL E. ANDER NO. CE -4391 SITE PLAN SEE SITE PLAN i a WAS GROUND WATER ENCOUNTERED? No IF YES QR MONITORING 2% DEPTH OF WATER AFTER MONITORING: NONE 0 DATE OF MONITORING' 10/16/13 P E DENSE BOH @ 19.5' DATE READING GROSS TIME (MINUTES) NET TIME (MINUTES) DEPTH To WATER (INCHES) NET DROP (INCHES) TEST HOLE PRESOAKED PRIOR TO TESTING: 10/9 1 10:58 6.50" 2 11:28 30 7.44" 0.94" 3 11:30 6.31" 4 12:00 30 7.19" 0.88°' 5 12:03 6.44" 6 12:33 30 1 8.381, .94" PERCOLATION RATE:32 (MIN/INCH) PERC. HOLE DIA. 6" (INCHES) TEST RUN BETWEEN: 4.5 FT. and 5.5 FT. COMMENTS: TEST HOLE PRE SOAKED PRIOR TO TEST. TEST PERFORMED BY ANDERSON ENGINEERING. I, MICHAEL E. ANDERSON CERTIFY THAT THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPLE GUIDELINES IN EFFECT ON THIS DATE: 10/20/13 DEPTH (feet) I- 2 3 4 5 6 7- 9- 10 - II 14 15 16 17 18 19 MUNICIPALITY OF ANCHORAGE DEVELOPMENT SERVICES DEPARTMENT 4700 BRAGAW STREET ANCHORAGE, AK 99519-6650 SOILS LOG - PERCOLATION TEST LEGAL DESCRIPTION: LOT 6, HORIZON SUBDIVISION PERFORMED FOR: TROY DAMS HOMES DATE: 10/9/13 PROJECT No.: PARCEL ID#: TECHNICIAN: A. HARALA OB/OG m TEST HOLE 6 SILTY GRAVEL WITH SAND d GM a a . Q DENSE a Q e BOH @ 19' WAS GROUNDWATER ENCOUNTERED? No IF YES C WH DATE DEPTH OF WATER AFTER MO GROSS TIME (MINUTES) DATE OF MO DEPTH TO WATER HES) (INC 4F 49th AEL E. ANDER No. CE -4381 SITE PLAN SEE Sl FE PLAN M I DEPTH? J N[TORINO NONE NITORING: 10/16/13 P NI E 2% DATE READING GROSS TIME (MINUTES) NET TIME (MINUTES) DEPTH TO WATER HES) (INC NET DROP (INCHES) TEST HOLE PRESOAKED PRIOR TO TESTING: 10/9 1 11:10 7.63" 2 11:40 30 10.88" 3.25" 3 11:41 7.50" 4 12:11 30 10.94" 3.44" 5 12:12 7.56" 6 12:42 30 11.06" 3.50" PERCOLATION RATE:9 (MIN/INCH) PERC. HOLE DIA. 6 (INCHES) TEST RUN BETWEEN: 4.5 FT. and 5.5 FT. COMMENTS: TEST HOLE PRE SOAKED PRIOR TO TEST. TEST PERFORMED BY ANDERSON ENGINEERING. 1, MICHAEL E. ANDERSON CERTIFY THAT THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPLE GUIDELINES IN EFFECT ON THIS DATE: 10/20/13 Y Parcel I.D. 051-324-26 e. Municipality of Anchorage On -Site Water and Wastewater Prograrfi (907) 343-7904,! , • r T Certificate of On -Site Systems Approval 1. GENERAL INFORMATION Complete legal description 18273 Muldrow Street Eagle River, AK 99577 Location (site address) Expiration Date: E' 1Z - Horizon Estates, Lot 6 Current Property owner(s) Troy Davis Homes, Inc. Day phone 357-9394 Mailing address 165 E. Parks Highway, No. 200 Wasilla, AK 99654 Real Estate Agent Day phone 2. TYPE OF DWELLING: Fx7l Single Family (w/wo ADU) ❑ Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) 3. NUMBER OF BEDROOMS: Four 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well 7 Individual El Individual Water Storage ❑ Holding Tank ❑ Community Class Well ❑ Community ❑ Public Water System ❑ Public Sever ❑ WaiverNariance request engineer, unless otherwise requested by the engineer. COSA Fee $ III -0 Date of Payment Receipt Number COSA# Waiver Fee $ Date of Payment Receipt Number Waiver # 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below. I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the -on-site water, supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm Anderson Engineering Phone Address P.O. Box 240773 Anchorage, AK 99524 Engineer's Printed Name Michael E. Anderson, P.E. 6. DSD SIGNATURE t/ System #1 Approved for bedrooms System #2 Approved for Disapproved Conditional approval for bedrooms 522-7773 Date 2/1/15 d ��b L � _j %j 9 � °EY bedrooms, with the following stipulations: // gy. Original Certificate Date: ` 3 The M ' a' of orage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the represen ations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. ATTACHMENTS: COSA Checklist X Nitrate Advisory Septic System Advisory Arsenic Advisory Well Flow Advisory Other COSA bale sheet_r , If more than 1 septic system is on the lot: COSA Checklist # of _ Structure served by this system Certificate of On -Site Systems Approval Checklist Legal Description: Horizon Estates, Lot 6 A. WELL DATA Well type Private If A, B, or C provide PWSID # _ Date completed 8/28/14 Sanitary seal (Y/N) Y Total depth 145 ft. Cased to 140 ft FROM WELL LOG Date of test 8/28/14 Static water level 34 ft. Well production 40 g.p.m. WATER SAMPLE RESULTS: Coliform 0 colonies/100 mL Nitrate •148 mg/L Arsenic ND ug/L Date of sample: 1/22/15 Parcel ID: 051-324-26 Well Lag (Y/N) Y Wires properly protected (Y/N) Y Casing height (above ground) >18 in. AT INSPECTION ft. Collected by: Anderson Engrg. B. SEPTICIHOLDING TANK DATA Tank Type/Material Septic/Steel Date installed 9/21/14 Tank size 1,250 gal. Number of Compartments 2 Cleanouts (Y/N) Y Foundation cleanout (Y/N) Y Depression over tank (Y/N) N High water alarm (Y/N) Date of pumping New Const. Pumper C. ABSORPTION FIELD DATA R Date installed 9/21/14 Soil rating (g.p.d./ftZ or ftZ/bdrm) •8 GPD/SF System type Deep Trench Length 47 ft. Width 3 ft. Gravel below pipe 8.0 ft. Total depth 11-12 ft. Eff. absorption area 752 ft2 Monitoring tube Y Depression over field N Date of adequacy test New Const, Results (Pass/Fail) For _ bedrooms Fluid depth in absorption field before test in. Water added gal. New depth in. Elapsed Time: min. Final fluid depth in. Absorption rate >= g.p.d. Any rejuvenation treatment (past 12 mo.) (Y/N & type) N If yes, give date D. LIFT STATION Date installed "Pump on" level at Datum Size in gallons in. "Pump off" level at _ Cycles tested E. SEPARATION DISTANCES WELL ON LOT TO: _ . Manhole/Access (Y/N) in. High water alarm level at Meets alar & circuit requirements? Septic tank/lift station on lot >100 On adjacent lots > 100' >1 00' On adjacent lots >1 00' Absorption field on lot 1 Public sewer main NIA Public sewer manhole/cleanout NSA Sewer /septic service line >25' Holding tank N/A Animal containment areas >50' Manure/animal excrete storage areas >100' SEPTIC/HOLDING TANK ON LOT TO: Building foundation >51 Property line >5r Water main > 10' Water service line >10' Wells on adjacent lots >100' ABSORPTION FIELD ON LOT TO: Property line >10' Building foundation >10' Water Service line >10' Surfacewater >100' Curtain drain None Noted Wells on adjacent lots >100' F. COMMENTS G. ENGINEER'S CERTIFICATION l certify that i have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this date. Engineer's Printed Name Michael E. Anderson, P. E. Date 211.115 COSA brown sheet_10-10-12.doc Absorption field >51 Surface water >100' Water main N/A Driveway, parking/vehicle storage > 10' OF,A .,- 49 TH k- MICHAEL E. ANDERSON J CE -4381 ' I® �E Fd z ...... in. 5 Lot 6 has 3 3 40,049.47 SQ.FT. OF AREA a ey I 0493 �rrs"*X5542 S� g mew Melva wf1G 15' T & E ESMT. 8 MULDROW STREET 8 RES� 9 V p "g Aa 1V/ \ \�•4g33• �e \� 7 Assumed Datum. FOR: TROY DAVIS HOMES Date Scale Legal Description 10-22-14 1" = 60' FORRES& ASSOCIATES. INC. Grid As -Built Survey Lot 6 Block F.O. Box 232293 NW 453 2140207 HORIZON ESTATES - Anchorage, Alaska 99523 Drawn by Field Book SUBDIVISION (907) 227-5881 cef 244 - I hereby certify that the property described hereon has been surveyed +►��OF t116# - by me, or at my direction, and that the improvements situated thereon ��r,C�+„a.•Rj _ are within the property lines and do not overlap or encroach on the.♦•.' lying adjacent thereto unless otherwise shown. That no • /�- .property Improvements lying -encroachon on the property adjacent theretothe 49TH premises in question and that there are no roadways, transmission 'lines 00*: or other -easements on said property except as shown. - ••• a+« ..,•., a.,,.. �. It is 0.4,44, the responsibility of the owner or builder, prior to construction, ..........% to verify proposed building grade relative to finish grade and utility CHARLES E. FORBES pAw connections and to determine the existence of any easements, covenants, j I •,• LS -7326 ; yd s & or restrictions which do not appear on the recorded subdivision plat. �# a�g ,•� 2_15-14.,. ###0`of0 Listed distances prevail over scaling. - ••+•*' L9@a Reproduction may cause distortion. Wit ysssiooN!+