Loading...
HomeMy WebLinkAboutSKY MANOR LT 6 SKY MANOR5 ky Manor Lot 6 #051-193-45 Municipality of Anchorage Community Development Department Page 1 of 4 On-Site Water&Wastewater Program 4700 Elmore St. •P.O. Box 196650 Anchorage,AK 99519-6650 •http://www.muni.org/onsite•(907)343-7904 ON-SITE WASTEWATER INSPECTION REPORT Permit Number: OSP141207 PID Number: 051-193-45 El New ['Upgrade Name: ABSORPTION FIELD JOHN THOMSON W/CT CONSTRUCTION Address: O Deep Trench 0 Shallow Trench CO Bed 0 Mound 11404 JESSIE MAE CIR., EAGLE RIVER,AK 99577 0 Other Sod Rating: Total Depth from original grade: Phone: No.of Bedrooms: (907) 240-2020 6 0.7 GPO/Sq.Ft. 6.48-6.94 Ft. Depth to pipe invert from original grade: Gravel depth beneath pipe: LEGAL DESCRIPTION SEE DWG. Ft 0.56-0.59 Ft. Subdivision: Block: Lot: Fit added above original grade: Gravel length: SKY MANOR - 6 SEE DWG. Ft. 86'TOTAL(2 @ 43' EACH) Ft. I ownshlp: Range: Section: — Gravel width: Bede Number of toes: Distance between lines: 15F, 3 IN EACH 5 Ft. SEPARATIONDISTANCESTUaI absorption area: Number of trenches: Dist.between trenches: To Septic Absorption Lift Holding Public/Private 2 BEDS 10 Tank Field Station Tank Sewer Lines 1290 so.Ft. Ft. From 0 Well 100'+/ 100'+/ - - 25'+ TANK ® Septic D S.T.E.P. DHolding D Other •200'+ *200i+ Capacity:Manufacturer: Surface Water 100'+ 100'+ - - ANCHORAGE TANK 2000 Gal. Material: Number of compartments: STEEL Lot Line 5'+ 10'+ - - N/A 2 Foundation 5+ 10'+ LIFT STATION Curtain Drain _ Manufacturer: NONE KNOWN Gal. 'Pump on'level at: 'Pump off level at: High water alai at: Remarks: *TO PUBLIC WELL(NON-TRANSIENT,COMMUNITY) Pump Make&Moder Electrical Inspections performed by: PIPE MATERIAL House to tank D3034 Tank to D3034 drainfield Installer GREEN GENERAL Drainfield D3034 CO/MT D3034 Inspector GEG, Ltd. BENCH MARK (Assumed elevation) 105.08 Ft. Inspection Location and Description: Dates: 1st 10/29/2014 2nd 10/30/2014 3rd 10/30/2014 4th 11/10-11/2014 TOP OF GARAGE SLAB ENGINEER'S SEAL Community Development Department Approval 00600.,;‘p OF . Lova o • • Conditional approval: Date: p �pO * . 4 • * �a D / f ,-y A. Co ness: ' (IM ' - - 3 vp - . •c°O (k)15:fP� ..'•3J/ . Jr, <sAd Approved: i` (7------ Al /C� Date: 3--/6.- 4��p 0�`�o PP 1 ,O000�oo inspection Report_t-t- .. C PERMIT NUMBER: PARCEL ID NUMBER: OSP 141207 AS - BUILT DRAWING 051-193-45 i 0 • // • •• NEW DRAINFIELDS ,, • / 15'T& ESMT. / • _ -•_ T_/' 9 1= 3010 r • • • i / J ,° •/COCO o • �C011 I ALTERNATE SITE •• // L CO9 0 _ •----•JCO12 L - • • •.,. • ,IMM r -1 ' • I TH#11 1 _ MT2 r° y • i TH#12+ ' ;• •• ti COe °°�C05 II°o • • •• j ALTERNATE SITES - ` • !. ,CO °• "�CO6 PROPOSED //*, • •. 1;., SEPTIC SYSTEM ., •. • 1 r , IST2 ° / I •, INSTALLED FLOW • • I 1 • ••• a I SPLITTER(FS) ---- • •' L - • •LST1 DBL1&2• • • - '4. . TH#12A • , • �--62'BY -55' ---= T- 62'BY 55' / SEPTIC SEPTIC i ESMT. •;/ • ESMT. • t. NEW 2000 EXISTING L Q t 6 /' GALLON 6 BEDROOM �� • . SEPTIC TANK DUPLEX , • / _ A.. w O /L FCO \ x 7 i a mo / m / NEW / 6 BEDROOM /r---______r_____.. i DUPLEX • -_-------J / / I 7 / FCO 6.2 - C05 83.3 126.9 \ APPROX. L--- - 4/ \ OF WATER LINE - / ST2 63.7 95.4 MT2 88.4 129.7 DRAINFIELD / DBL1 66.0 97.4 C07 107.9 128.2 / DBL2 67.8 98.6 C08 103.0 123.6 ALTERNATE SITE // FS 70.8 105.1 CO9 98.2 119.3 / CO 1 83.5 106.8 MT3 112.3 148.5 1 I CO2 78.2 102.3 C010 112.0 148.6 N I CO3 73.1 98.0 C011 107.1 144.6 I ill MT1 72.3 98.4 C012 102.1 140.6 - - C04 88.3 130.6 MT4 97.8 119.2 NEW WELL SCALE: I KEY BOX I 7 . ' 1'=40' 1-• 200 FEET WELL RADIUS o EXISTING WATER MAIN 1 4 II ._ `WELL 20'E . .�. . .� •L. I HOUSE � �.� � � 1 I, .._..-.. AllegliM111644"allift-........0 14. ' ..a,... 4 i •. . GARNESS ENGINEERING GROUP, Ltd �`•'� 9 i" CIVIL&ENVIRONMENTAL ENGINEERS • . • 3701 E.TUDOR ROAD.SUITE 101•ANCHORAGE,Al)99507•PHONE(907)3376179•FAX(907)33&3246•WEBSITE:WWI.gWo0sen9lne•n°g.com •0110 . PREPARED FOR: PHONE NUMBER: PAGE NUMBER: • Johi -ss JOHN THOMSON (907)240-2020 2 OF 4 �♦C. 7-7953 _� LEGAL DESCRIPTION: DRAWN BY: ♦♦ /\,,,'•••,•• I A�0 SKY MANOR S/D; LOT 6 J.L.M ♦♦j FO� 61.1`,,�•,.P�, 4�. TYPE OF WORK: DATE: ��4,;�`S":�*** AS- BUILT DRAWING 23/13/2015 PERMIT NUMBER: AS_BUILT DRAWING PARCEL ID NUMBER: OSP 141207 051-19345 NORTH BED FINAL GRADE =97.93-98.71 FILTER FABRIC C7 CO CO 7 C ORIGINAL GRADE AT HIGHEST POINT =97.67 MOA 2'SAND FILTER INVERT OF DISTRIBUTION LINE=91.75(AVG.) TOP OF SAND=91.19 15'WIDE BOTTOM OF BED =89.17(AVG.) SOUTH BED FINAL GRADE =99.65-100.53 FILTER FABRIC 7 MoT • CO o — ORIGINAL GRADE AT HIGHEST POINT =101.00 A10A 2'SAND FILTER INVERT OF DISTRIBUTION LINES=94.65(AVG.) TOP OF SAND=94.08 I 15'WIDE BOTTOM OF BED =92.00(AVG.) .00\\\\\111 .'4�E4 OF 4.4 GARNESS ....::q6,4. • ENGINEERING GROUP, Ltd r• �')itir • - '.. ::.* •• • ;; 1. CIVIL&ENVIRONMENTAL ENGINEERS •'�� • 3701 E.TUDOR ROAD.SUITE 101'ANCHORAGE.AK 99507'PHONE(9071337-6179'FAX(907)330-3246'WEBSITE.ww«.ganasaargnxmg.can , • • PREPARED FOR: PHONE NUMBER: PAGE NUMBER: 0 e • ness : LI IffJOHN THOMPSON (907) 240-2020 3 OF 4 •j�'�J,.. 7993 _• ��LEGAL DESCRIPTION: DRAWN BY: �..���..•• b .•••�k74SKY MANOR S/D; LOT 6 D.J.G./J.L.M. 4a e0 pR� . e'. \ • TYPE OF WORK DATE: ,,N\ \\\\��• PROFILE AS BUILT 3/13/2015 J PERMIT NUMBER: AS-BUILT D RAW I N G PARCEL ID NUMBER: OSP'141207051-193-45 2"OF INSULATION (PER CONTRACTOR) FINAL GRADE= 101.25-102.21 TOP OF TANK ST 1 ST2 AT INLET=97.60 TOP OF TANK _- __AT OUTLET=97.60 INVERT OF BUNG NEW 2000 GALLON AT INLET=97.05 SEPTIC TANK INVERT OF BUNG AT OUTLET=96.81 •4..`� OF. i1441 a • , ..•........ . .S ♦♦1 GA,RNESS ENGINEERING GROUP, Ltdil"�' 9 '� 0. • `.'� • • CIVIL&ENVIRONMENTAL ENGINEERS •• + •go 3701 E.TUDOR ROAD.SUITE 101'ANCHORAGE.AK 99507'PHONE(907)3376179'FAX(907)338-3248'WEBSITE',w.7w.gamoaamgneem9.Fom .•• CC PREPARED FOR: PHONE NUMBER: PAGE NUMBER: ••• ♦ �^ : J ••ey A. :• - JOHN THOMPSON (907) 240-2020 4 OF 4 ♦�J,f; C -795 :. LEGAL DESCRIPTION: DRAWN BY: • ♦♦��'•..• (� I f.• <•*a SKY MANOR S/D; LOT 6 D.J.G./J.L.M. ♦ F6 '•• .... •'�0., •• TYPE OF WORK: DATE: •444 ROFES`;:,n,..- PROFILE AS BUILT 2/2/2015 II II �P��••�F �:9S..ii ,or t° dig.. , :;?s( 1 .• .# .. .. OP tt °. • , .. CIVIL&ENVIRONMENTAL ENGINEERS i 4 A E5S ENGINEERING GROUP Ltd 37n.F.TUDOR ROAD.SUTE 101•ANCHORAGE,Al(99507'PHONE(907)3374179'FAX(907)3383246•WEBSITE'%H..gnmes5°RRIReervp. rn �co ..'....-.tin...• 'f !SOIL LOG - PERCOLATION TESTI %c)•-. a *• A.Gar ess A= ♦ % � -793 : �ci LEGAL DESCRIPTION: SKY MANOR SUBDIVISION;LOT 6 V: 7 -S-..***** • V PERFORMED FOR: JOHN THOMSON W/C&T CONSTRUCTION DATE: 2/3/2015 if 4 PROF ESSSSS1()NP.4- DEPTH' -- _ ,IIllItlilis*��4 (feet) _-= ORGANICS TEST HOLE #12A 1 - 2 — r£ LOAM SOIL CLASSIFICATIONS SITE PLAN • ° o GW '-== ORG • GP-GM • • . GP 1Jyyr^ ML 3 — • • . • • 1� GM ,i0' CL 4 -- /Y GC � OL �P •• ° o°p cSW 1� � MH �Q • oo°o o 5 -- • :le � •%. SP /� CH O '� • }t),,,i). sm ,/ � ,� OH 6 — • " SC N' • PG • -• 'S , DEPTH 7 - • • GP-GM GROUNDWATOER DATE l<,P N • WITH SOME 8 -- , ' LARGE DRY 2/3/2015 • COBBLES/ • , BOULDERS SCALE 9 -- • • 1-=ur • • 10 -- • • • . CLOCK NET TIME WATER LEVEL NET DROP 11 -- • . DATE READING TIME (MINUTES) READING (INCHES) 12 -- • •' . • � :•, SSN 14 -' • : . .• �P-- .\NSE 15 • Oe • \,\" N • •• yGP 16 - B.O.H. PgS-09 17 - 213j20y 18 - 19 — PERCOLATION RATE <1 (MIN./INCH) PERC. HOLE DIA. 6 (INCHES) TEST RUN BETWEEN 4 FT. AND 5 FT. 20 A FOUR HOUR PRESOAK WAS PERFORMED: ❑ YES •NO SOILS LOGGED BY: JODY MAUS PERCOLATION TEST PERFORMED BY: JODY MAUS COMMENTS: PERCOLATION READINGS ARE WITHIN 1/16 OF INCH. PERFORMED BY GEG, Ltd. I,JEFFREY A. GARNESS, CERTIFY THAT THIS WAS PFO MED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE: ,fib �o— Contractors Statement for Water Main and Water Service Lines October 6, 2014 To whom it may concern: I, Dan Green, Owner of Green General Contracting, hereby certify that all water mains and water service lines for Sky Manor Water System that were installed by Green General Contracting, are ten (10) feet away from all septic tanks and drainfields. /10 Signature of Owner Date Dan Green, Owner Green General Contracting 15939 Division Street Chugiak, AK 99567 Phone: (907) 696-1805 On -Site Wastewater Disposal System Permit MUNICIPALITY OF ANCHORAGE Development Services Department On -Site Water & Wastewater Program 4700 Elmore Road, PO Box 196650 Anchorage, AK 99519-6650 Telephone: (907) 343-7904 Permit Number: OSP141207 Tax Code Number: 05119345000 Work Type: Septic Initial Permit Effective Dates: August 25, 2014 to August 25, 2015 Design Engineer: GARNESS ENGINEERING GROUP LTD Subdivision: SKY MANOR Site Legal Address: SKY MANOR LT 6 G:1159 Owner/Address: THOMSON JOHN E 11404 JESSIE MAE CIR EAGLE RIVER AK 995770000 Site Mailing Address: Lot Size in Sq Ft: 40000 Total Bedrooms: 6 This permit is for the construction of: Y Disposal Field Y Septic Tank N Holding Tank N Privy N Private Well N Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80). 3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either: A. Open and Close on the same day. B. Covered, sealed, and heated to Drevent freezing Special Provisions: The entire subsurface disposal field and/or alternate is not within a 30 foot radius of a percolatior test. The Engineer needs to do an additional percolation test(s) prior to the construction of the septic field. Please submit stamped and signed results with the As -built Inspection Report. If thr �esults require a design change, construction of the system will stop pending On -Site review and pproval. AMC 15.65.060.6.3 Received Issued By MUNICIPALITY OF ANCHORAGE Community Development Department Phone: 907-343-7904 Development Services Fax: 907- 343-7997 On -Site Water & Wastewater Program Mayor Dan Sufflvan On -Site Sewer/Well Permit Application For A Single Family Dwelling Parcel I.D. 0151 ^ lot's, — qIs Property owner(s) JOHN THOMSON W/ CT CONSTRUCTION Day phone 240-2020 Mailing address 11404 JESSIE MAE CIRCLE * EAGLE RIVER, AK 99577 Site address NEEDELS LOOP * CHUGIAK, AK 99567 Legal description (Sub'd, Block & Lot) SKY MANOR; LOT 6 Legal description (Township, Section & Range) Lot Size Sq.Ft. Number of Bedrooms 6 APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DEWELLING: (®all that apply) Initial ® Single Family (SF) ❑ Absorption Field ® ❑ (w/wo ADU) Septic Tank ® Upgrade Renewal ❑ Duplex (D) Holding Tank ❑ Multiple Dwellings ❑ Privy ❑ (SF and/or D) Private Well ❑� U B 1I T TAL Water Storage El�Vi THIS APPLICATION INCLUDES A VARIANCE/ WAIVUR jtgQW$T FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal codes. GARNESS ENGINEERING GROUP, Ltd. (Signature of property owner or authorized agent) Permit/Rush Fees: 5(A - Waiver Fees: Date of Payment: (o I IC0 W J±�, Date of Payment: Receipt Number: cqc q-1 Receipt Number: Permit No. 05-914 12,01 Waiver No. (Rev. 09/12) GARNESS ENGINEERING GROUP, Ltd CIVIL & ENVIRONMENTAL ENGINEERS June 12, 2014 Municipality of Anchorage Development Service Department On -Site Water & Wastewater Program 4700 Elmore Road P.O. Box 196650, Anchorage, Ak 99519-6650 (907)343-7904 Ref: Proposed Septic System for Sky Manor Subdivision; Lot 6 To whom it may concern: The proposed 6 bedroom duplex is to be served by a community water system (under construction) and a private septic system. Lot 6 has a platted septic drainfield easement on the property. S4 Group is in the process of revising this easement with the MOA Planning Department to allow the driveway to be centered on the property and divided the drainfield easement on each side of the driveway. As soon as this item is addressed and authorization (which may include replatting) is completed, we will provide you with a copy of the appropriate documentation. We are proposing that a new 2000 gallon septic tank and a bed type drainfield be installed. Two test holes were excavated on the property. The primary drainfield and alternate site will be designed around the 30 foot radii of TH#11 & TH#12. Comments regarding the design are summarized as follows: 1. SOILS: See the attached logs which shows the soil classifications, groundwater monitoring, and the percolation test results. 2. DRAINFIELD DESIGN: See attached design drawing for drainfield specifications. 3. SURFACE WATERS: There are no surface waters within 100 feet of the proposed septic system. 4. TOPOGRAPHY: As can be seen on the attached site plan and design drawing, the topography is shown. In short, there are no slope concerns with this installation and there are no cutbanks such as road ditch with 50 feet that will impact the installation of the septic system. We are unaware of any adverse impacts this installation would have on adjacent wells or septic systems. If you have anyAquestions, please contact us at 337-6179. Thank you for your assistance. P.E., M.S. NOTE: Attached is a site plan drawing, a design drawing, two soil logs, which are all partof the design package for this septic system. (Contact G.E.G. Ltd. for 8 page construction specification letter.) 3701 E. Tudor Road, Suite 101 * Anchorage, AK 99507-1259 Ph: (907) 337-6179 * Fax: (907) 338-3246 * Website: www.gamessengineering.com T&Eyy ESMT. . GEG, Ltd. HAS A 8 PAGE SPECIFICATION LETTER THAT PERTAINS TO THIS DESIGN. TO OBTAIN A COPY OF THE LETTER CONTACT< DEG. BY PROCEEDING FORWARD WITH THIS +`+ INSTALLATION, THE ENGINEER, WELL ALTERNATE DRILLER, CONTRACTOR AND PROPERTY SITE#3 OWNER AGREE THAT THEY HAVE READ THESE SPECIFICATIONS AND AGREE TO ACCEPT THE TERMS AND CONDITIONS ALTERNATE SITE #2 PROPOSED 6BEDROOM DUPLEX PROPOSED..-. Lot 5 SEPTIC SYSTEM TH ALTERNATE SITE NUMBER OF BEDROOMS:6 GALLONS PER DAY (GPD) :9DO PERCOLATION RATEIS: Q MIN/INCH PROPOSED APPLICATION RATE: 0.7 MINIMUM DRAINFIELD SQ.FT.: 1286 MAXIMUM DEPTH: 11 FEET WIDTH: 15 FEET LENGTH: 86 FEET (2 @ 43 FEET EACH) M.O.A. APPROVED SAND FILTER:2 FEET EFFECTIVE: 0.5 FEET REDUCTION FACTOR: N/A ACTUAL SQ.FT.: 1290 PLATTED 62' X 55' DRAINFIELD EASEMENTS (UNDER 3EVISION BY S4 GROUP) 2000 GALLON PROPOSED / 6 BEDROOM DUPLEX , 200 FOOT .,....... �. ... 1 /dam y ` /WELL RADIUS , J NOTE: THE CONTRACTOR SHALL HAVE THE EAST AND WEST J PROPERTY LINES, THE PLATTED GRAINFIELD EASEMENTS, AND THE / 200 FOOT WELL RADIUS FLAGGED BY REGISTERED LAND J SURVEYOR PRIOR TO CONSTRUCTION. ( . ALTERNATE SITE NOTE: ALT. SITE #2 HAS THE SAME DESIGN CRITERIA AS THE PRIMARY SITE. ALT. SITE#3 REQUIRES MOA CAT. I III ADVANCED WASTEWATER SYSTEM PER PLAT NOTE #10. ALT. SITE 1 #3 IS 10' WIDE BY 30 FOOT LONG. MAX. DEPTH, SAND FILTER, & I EFFECTIVE DEPTH THE SAME. I I I PROPOSED WATER LINE LOCATION+ - 9..% y ; .,.. EXISTING WATER MAIN �I EXISTING KEY BOX T i I }20'ESMT. .�.�.�.41J�. ...........I.-_ i.�.�.�.� i IJ i 1 GARNESS ENGINEERING GROUP, Ltd CIVIL & ENVIRONMENTAL ENGINEERS 3]111E.TUDORROAD, SUITE 101-ANOHOAE. AK 99M7 -PHONE (90P 397b179• PAN (2M MW243• MBSIIE: gartnurgMell aREPARED FOR: PHONE NUMBER: PAGE NUMBER: JOHN THOMSON (907) 240-2020 2 OF 3 .EGAL DESCRIPTION: DRAWN BY: SKY MANOR SUBDIVISION; LOT 6 J.L.M. 'YPE OF WORK: DATE: DESIGN OF PROPOSED SEPTIC SYSTEM 6/12/2014 z9v ALTERNATE SITE PROPOSED SEPTI INSTALL FLOW SPLITTER INSTALL DOUBLE CLEANOUTS FOOT NEW WELL WELL HOUSE 4H#12� (I .. I1pCt) I Fk II I • 1 V: •:i •r. �' Vii.. ✓i �Y 2000 GALLON PROPOSED / 6 BEDROOM DUPLEX , 200 FOOT .,....... �. ... 1 /dam y ` /WELL RADIUS , J NOTE: THE CONTRACTOR SHALL HAVE THE EAST AND WEST J PROPERTY LINES, THE PLATTED GRAINFIELD EASEMENTS, AND THE / 200 FOOT WELL RADIUS FLAGGED BY REGISTERED LAND J SURVEYOR PRIOR TO CONSTRUCTION. ( . ALTERNATE SITE NOTE: ALT. SITE #2 HAS THE SAME DESIGN CRITERIA AS THE PRIMARY SITE. ALT. SITE#3 REQUIRES MOA CAT. I III ADVANCED WASTEWATER SYSTEM PER PLAT NOTE #10. ALT. SITE 1 #3 IS 10' WIDE BY 30 FOOT LONG. MAX. DEPTH, SAND FILTER, & I EFFECTIVE DEPTH THE SAME. I I I PROPOSED WATER LINE LOCATION+ - 9..% y ; .,.. EXISTING WATER MAIN �I EXISTING KEY BOX T i I }20'ESMT. .�.�.�.41J�. ...........I.-_ i.�.�.�.� i IJ i 1 GARNESS ENGINEERING GROUP, Ltd CIVIL & ENVIRONMENTAL ENGINEERS 3]111E.TUDORROAD, SUITE 101-ANOHOAE. AK 99M7 -PHONE (90P 397b179• PAN (2M MW243• MBSIIE: gartnurgMell aREPARED FOR: PHONE NUMBER: PAGE NUMBER: JOHN THOMSON (907) 240-2020 2 OF 3 .EGAL DESCRIPTION: DRAWN BY: SKY MANOR SUBDIVISION; LOT 6 J.L.M. 'YPE OF WORK: DATE: DESIGN OF PROPOSED SEPTIC SYSTEM 6/12/2014 z9v ALTERNATE SITE PROPOSED SEPTI INSTALL FLOW SPLITTER INSTALL DOUBLE CLEANOUTS FOOT NEW WELL WELL HOUSE INSTALL FLOW 4" 2' 4" SOLID FILTER FABRIC INVERT OF DISTRIBUTION LINES (TVP.) — TOP OF SAND — BOTTOM OF BED — 4" PERFORATED PIPE 43 FEET LONG 4" PERFORATED PIPE O 26 =o iS p 1 2.5' 12" 10 2.5' 25- 39 FEET T 43 FEET LONG 0 0 0 �MT FINALGRADE o 0 FEET WIDE I MAX. OINT TEST HOLE DEPTH IS 16 FEET (NO WATERT GARNESS ENGINEERING GROUP, Ltd CIVIL & ENVIRONMENTAL Et Rol ... 3701 E. WC RMD, SUDS IM-ANCHOP E,PK007- PHME(01 MM1]9•FM(On 33MM6' MB3DE:wnw.pmwwrylnedhp.am PREPARED FOR: PHONE NUMBER: PAGE NUMBER:SVA' JOHN THOMSON (907) 240-2020 3 OF 3 LEGAL DESCRIPTION: DRAWN SKY MANOR SUBDIVISION; LOT 6 J.L.1 i TYPE OF WORK: DATE: DETAIL DRAWING OF PROPOSED DRAINFIELD 6/1212014 TH#11 TH#12 ..1....- OFESS\Ct'.i GARNESS ENGINEERING GROUP, Ltd. CONSULTANTS & GENERAL CONTRACTORS SOIL LOG - PERCOLATION TEST LEGAL DESCRIPTION: SKY MANOR S/D, LOT 6 PERFORMED FOR: JOHN THOMSON W DEPTH (feet ORGANICS TEST HOLE # 1 1 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 SOIL CLASSIFICATIONS DEPTH TO GROUNDWATER DATE IIIII1111 1/30/13 DRY 1/31/13 DRY 2/6/13 DRY 5/29/2013 <1:40 MIN. 0" IIIIIIII �//Zi 3 NMI �y� !HYYSi I�lllltll 4 �i�� • 6" 5 — — 6" DEPTH TO GROUNDWATER DATE DRY 1/30/13 DRY 1/31/13 DRY 2/6/13 DRY 5/29/2013 SEE ATTACHED DRAWINGS DATE READING CLOCK TIME NET TIME WATER LEVEL (MINUTES) READING NET DROP (INCHES) 1/31/13 1 — — 6" — 2 — <1:40 MIN. 0" 6" 3 — — 6- 4 — <1:40 MIN. 0" 6" 5 — — 6" — 6 — <1:40 MIN. 0" 6" 19 PERCOLATION RATE <1 (MIN./INCH) PERC. HOLE DIA. 6 (INCHES) TEST RUN BETWEEN 4.0 FT. AND 5.0 FT. 20 A FOUR HOUR PRESOAK WAS PERFORMED: ❑ YES NO SOILS LOGGED BY: JODY MAUS PERCOLATION TEST PERFORMED BY: JODY MAUS COMMENTS: PERFORMED BY GEG, Ltd. I, JEFFREY A. GARNESS, CERTIFY THAT THIS WAS PE ORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE: GARNESS ENGINEERING GROUP, Ltd. . CONSULTANTS & GENERAL CONTRACTORS 01 E. TWOR RND. WITE 101 • MCROR.WE, W. 99507 • WONE: (907)337-6199 Inv: 907)3.16-S46 • WE69RE: gorwa ngine ru SOIL LOG - PERCOLATION TEST LEGAL DESCRIPTION: SKY MANOR S/D, LOT 6 PERFORMED FOR: JOHN THOMSON DATE: 1/30/2013 DEPTH (feet) ORGANICS TEST HOLE #12 1 7 8 9 10 11 12 13 14 15 16 17 18 DEPTH TO GROUNDWATER DATE LOAM SOIL CLASSIFICATIONS DRY f 1. DRY 2/6/13 DRY illi — <30 SEC. 0'• 6" 3 — L 'ML 4 — <30 SEC. 0" 6" P �III11111 — 6•' — 6 — <30 SEC. 01' 6" Ilrlll'll CIL /.%G CNNH • IIIIIIIII IIIIIIIIISMD'.�8. • �sft�si!SC 7 8 9 10 11 12 13 14 15 16 17 18 DEPTH TO GROUNDWATER DATE DRY 1/30/13 DRY 1/31/13 DRY 2/6/13 DRY 5/29/2013 ........... A. r .......ness........ .- CE 79 3 SEE ATTACHED DRAWINGS DATE READING CLOCK TIME NET TIME WATER LEVEL NET DROP (MINUTES) READING (INCHES) 1/31/13 1 — — 6" — 2 — <30 SEC. 0'• 6" 3 — — 6" — 4 — <30 SEC. 0" 6" 5 — — 6•' — 6 — <30 SEC. 01' 6" 19� PERCOLATION RATE <1 (MIN./INCH) PERC. HOLE DIA. 6 (INCHES) TEST RUN BETWEEN 4.0 FT. AND 5.0 FT. 20 A FOUR HOUR PRESOAK WAS PERFORMED: ❑ YES ONO SOILS LOGGED BY: JODY MAUS PERCOLATION TEST PERFORMED BY: JODY MAUS COMMENTS: PERFORMED BY GEG, Ltd. I, JEFFREY A. GARNESS, CERTIFY THAT THIS WAP RFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE: Municipality of Anchorage �Y On -Site Water & Wastewater Program *e� (907) 343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL Parcel I.D. 051-193-45 Expiration Date: (✓? �� (� 1. GENERAL INFORMATION Complete legal description SKY MANOR S/D; LOT 6 Location (site address) Current Property owner(s) Mailing address Real Estate Agent 2. TYPE OF DWELLING: NHN NEEDELS LOOP, CHUGIAK, AK, 99567 JOHN THOMSON (C&T CONSTRUCTIOM Day phone 240-2020 11404 JESSIE MAE CIRCLE *EAGLE RIVER, AK ❑ Single Family (w/wo ADU) ® Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) 3. NUMBER OF BEDROOMS: Day phone 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well ❑ Individual On-site Individual Water Storage ❑ Individual Holding tank Community Class "A" Well Community On-site ❑ Public Water System ❑ Public Sewer ❑ WaiverAhariance request for: IWA Distance: Received by: ��/I Date: COSA to be released to the engineer, unless otherwise requested by the engineer. COSA Fee $ 1,::.Ol Waiver Fee $ _ Date of Payment 3 i(o ($ ( Date of Paymen Receipt Number 0-72-1 0& Receipt Number COSA # CKDC 1 J 1 ()?5- Waiver # 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. 1 further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm GARNESS ENGINEERING GROUP, Ltd. Address 3701 E. TUDOR ROAD, SUITE 101 * ANCHORAGE, AK 99507 Engineer's Printed Name - JEFFREY A. GARNESS, P.E. Engineer's Comments: In conducting this evaluation, GEG, UD. attempted to provide a thorough, conscientious engineering analysis of the system in accordance with ADEC and MOA DSD Guidelines & Regulations. The repo. -ted results described the performance of the system under the conditions encountered at the time of the test and separation distances measured to readily identifiable features. The operational life of all wells and septic systems depend on the local soils condition, groundwater levels that may fluctuate during the year, and the water usage of the family being served by the system. These conditions are outside the control of the evaluator of the system. Satisfactory test results do not guarantee future performance of the system, nor do they guarantee that there are no hidden defects or encroachments. GEG, LTD. can therefore not provide any warranty or future estimate of how long the system will continue to meet the operational requirements of the ADEC or MOA DSD. The content of this report is for the sole benefit of the owner listed above. Any reliance upon or use of this report by any other person or party is not authorized, nor will it confer any legal right whatsoever 6. DSD SIGNATURE System #1 Approved for bedrooms. System #2 Approved for Disapproved. Conditional approval for bedrooms. Phone 337-6179 Date bedrooms, with the following stipulations: 4 yyTp 7 a frre' y A. Gornessr CE -79 34� »— ON-SITE WATER AND o WASTEWATER >� PROGRAM By: ;i Original Certificate Date: The unlcipalr y ornchorage Develop,emt Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the represenatations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTCHMENTS: / COSA Checklist t/ Nitrate Advisory Septic System Advisory Arsenic Advisory Well Flow Advisory Other (R— iimsl If more than 1 septic system is on the lot: COSA Checklist # _of_ Structure served by this system Certificate of On -Site Systems Approval Checklist Legal Description: A. WELL DATA Well type COMMUNITY Date completed Total depth ft. Date of test Static water level Well production WATER SAMPLE SKY MANOR S/D; LOT 6 Parcel ID: 051-193.45 IOMMUNITY WELL 1Q B, or C provide PWSID# 216807 Well Log (Y/N) _ Sanitary seal (Y/N) _ Wires properly protected Cased to ft. Casing height (above -In FROM WELL LOG Coliform _--� colonies/100 ml. Nitrate AT ft. g.p.m. g.p.m. mg./L. Collected by: in. Ars—enic: ug./L. Date of sample: B. SEPTIC/HOLDING TANK DATA Tank Type/Material SEPTIC/STEEL Date installed 10/29/2014-11/10/2014 Tank size 2000 gal. Number of Compartments E Cleanouts (Y/N) YES Foundation cleanout (Y/N) YES Depression over tank (Y/N) NO High water alarm (Y/N) NIA Date of pumping NEW TANK Pumper C. ABSORPTION FIELD DATA e�ow FiNu owwe NORTH/SOUTH 10/28/2014 - Date installed 11/10/2014 Soil rating.p.d./ r ftz/bdrm) 0_7 System type DUAL BEDS 2 6 43 FT Length 89 TOTAL ft. Width 15/15 ft. Gravel below pipe 0.56/0.59 fl. •6.7-T& Total depth me -6.5 ft. Eff. absorption area 1290 ft2 Monitoring tube YES Depression over field NO Date of adequacy test NEW SYSTEM Results (Pass/Fall) For=bedrooms Fluid depth in absorption field before test = in. Water added =gal. New depth =in. Elapsed Time: = min. Final fluid depth = in. Absorption rate >= g.p.d. Any rejuvenation treatment (past 12 mo.) (Y/N & type) If yes, give date - D. LIFT STATION Date installed Size in gallons Manhole/Access "Pump on" level at in. "Pump off' level at a er alarm level at in. Cycles tested Meets alarm & circuit requirements? E. SEPARATION DISTANCES SEPARATION DISTANCES FROM WELL ON LOT TO: COMMUNITY WELL Septic tank/lift station on lot On adjacent Absorption field on lot On adjacent lots Public sewer main Sewer /septic service manhole/cleanout Holding tank Manure/animal excrete storage areas SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundation 5'+ Property line 5'+ Absorption Feld 5'+ Water main 101+ Water service line *10'+ Surface water 1001+ Wells on adjacent lots 209+ TO PUBLIC / 100'+ TO PVT. SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line 104 Building foundation 101+ Water main 101+ Water service line *101+ Surface water 1001+ Driveway, parking/vehicle storage 10'+ Curtain drain NONE KNOWN Wells on adjacent lots 200'+ TO PUBLJC / 100'+ TO PVT F. COMMENTS *SEE ATTACHED LETTER FROM GREEN GENERAL CONTRACTING. G. ENGINEER'S CERTIFICATION 1 certify that I have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA COSH guidelines in effect on this date. Engineers Printed Name JEFFREY A. GARNESS Date 3 )/b I/S (Rev. 10/12/12) h, I ASBUILT SEWARD & ASSOCIATES LAND SURVEYING 694-0829 1 HEREBY CERTIFY THAT I HAVE SURVEYED THE SCALE' FOLLOWING DESCRIBED PROPERTY' _ �� �� OF A ash /af'eo�r; DATE v ( ......,���� AND THAT NO F.4GCROACHMENTS EXIST EXCEPT AS z��S m /t� •' Is, INDICATED. IT IS THE RESPONSIBILITY OF THE 41. Y, g OWNER TO DETERMINE THE EXISTENCE OF ANY GRID: r EASEMENTS, COVENANTS, OR RESTRICTIONS m'lsiizs�' i WHICH DO NOT APPEAR ON THE RECORDED SUBDI- VISION PLAT. UNDER NO CIRCUMSTANCES SHOULD FB` LS - 59 ANY DATA HEREON BE USED FOR CONSTRUCTION����� OFFENCE LINES, OR FOR ESTABLISHING BOUND- I� % t4� ARY LINES. DRAWN' k ° skFr• �" �'