MUNICIPALITY OF ANCHORAGE
On -Site Water & Wastewater Program
PO Box 196650 4700 Elmore Road
Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997
http://www.muhi.org/onsite
On -Site Water System Permit
Permit Number: OSP201250
Work Type: Well Renewal
Tax Code Number: 01516421000
Site Legal Address: MOOSE RUN LT 1 G:2641
Site Mailing Address: 11050 BOULDER CIR, Anchorage
Owner: SPENCER DAVID WILLIAM &
Design Engineer:
This permit is for the construction of:
❑ Disposal Field ❑ Septic Tank ❑ Holding Tank ❑ Privy
Effective Date
Expiration Date:
Lot Size in Sq Ft:
Total Bedrooms:
Dell itvtIne11t
7/17/2020
7/17/2021
101180
Q Private Well ❑ Water Storage
All construction shall be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80)
3. The wastewater code requires inspections during the installation. The engineer shall notify the Development
Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
shall be either:
a. Opened and Closed on the same day, or
b. Covered, sealed, and heated to prevent freezing
Special Provisions: To close this permit please submit:
1. Well Log
2. Pump Install Log
3. Water sample results
4. Well Decommissioning Log for the existing well
8�6 w C.O Gael( �t«>2 wto�� fio a'�e, 5►��y-l' corner.
Received By:
Issued By: A� 00-r1k
Date:
Date:
1
MUNICIPALITY OF A
Development Services Department c > ' Phone- 907-343-7904
On -Site Water & Wastewater Section - Fax: 907-343-7997
ON-SITE SEPTIC/WELL PERMIT APPLICATION
Parcel I. D. 015-164-21
Property owner(s) Ann Reeves , David William Spencer
Mailing address 11000 Vosikof PI
Site address 11050 Boulder Circle
Legal description (Sub'd., Block & Lot) Moose Run , Lot 1
Legal description (Township, Range & Section) NA
Lot Size 10 1, 180 Sq. Ft. Number of Bedrooms
Day phone 907-346-3582M
APPLICATION IS FOR:
APPLICATION IS AN: TYPE OF DWELLING:
(® all that apply)
Absorption Field
❑
Initial E] Single Family (SF) Q
(w/wo AD U)
Septic Tank
❑
Upgrade ❑ Duplex (D) ❑
Holding Tank
❑
Renewal Q
Multiple Dwellings ❑
Privy
❑
(SF and/or D)
Private Well
Water Storage
❑
THIS APPLICATION INCLUDES A WAIVER REQUEST FOR:
Original application contained a slope waiver for the septic systb Distance:
I certify that the above information is correct. I further certify that this is in accordance with
applicable Municipal Codes.
7/13/2020
(Signature of property owner or authorized agent)
Permit/Rush Fees: oV,7!15� 00111 D'la \/\�aivr�r FACC'
Date of Payment:7�l % D
Receipt Number: 06173 1)
Permit No. 06PZ-012 50
Date of Payment:
Receipt Number:
Waiver No.
GADevelopment Services\Building Safety\On Site Water and Wastewater\Forms\Client Forms\Permit Application.doc
3V
/a
nc
D
B ulder "pringn,
Lot
1 O'S k--(DTP-
e�
L4j
PR&OsEp
Pr ou-s Proposed Well
. I .
- -! '
IJI
j: L iy n 491E .
10
L t
INSTALLED f-SEDROOM SEPTIC SYSTEM
INSTALLED f000 GALLON SEP77C TANK
cz,
TRENCH LENGTH 50 FEET
TRENCH WIDTH 5 FEET
O
MAX EXCAVATION DEPTH 1.5 FEET
ROCK DEPTH 0.5 FEET
1 Moos & n:.. ;'Septi; 2" INSULATION
an b' set
ing TiesV'no longer
I n '
T 1, each . OSE,�p
d, shed has been M0 ul
't
ved sliyotly Field, 100' ffset
III I BDIRM
SWING 77ES A, B
SFR
Co- C 24'
CO. 0
CE 29 15.5
17F CO.0 F 38. 25.5' F
Reserve ar a for ain DF M. T. G 24. 34' e
H 3f.0 43.0'
Dr CO.
field will ve north and
west to Avoid new well's
U,
100, of
I/ Bduilde.r"Sprincjs Lot,.-�32 e
Well offset,:mown on i 1
original draWing for Moose §Lw ;; /_
®R
Run Lt 1 seoic lobation;'
14 i I0'! UTIL
/EASE1 !s,
N6 rolp6sed Well
Locate n. Closest
4 ONTOUR LINES
Septic ank is on the
permitee lot 1,
Timberline LT 16, 100' oose Ru
Septic Offset
NOTF- THIS HOF A SURVMD PLA r WELL & SEPTIC
LOCATIONS TA FROM ON-S17F WATD? AND WASTE WA
DEPARTMENT ENTATION ALL LOCAMNS'SHOWN A
APPROXIMATE.
25 0 25 50 eft 100 I25 150
Boulder Spring
3, Lot
SCALE I' = 50
100' Septic 0 ff
3et
ND ENGINEERINGlffvo
RUN LOT I
SEPTIC SYSTEM ASBUILT
03 STIP AVENUE
ANCH. A . 9501
BILL SPENCER
DATO NDV It? 2014
(907) R79-
1-1009 IKL1F PLACE ANCORACE AK 99507
SHEEP R13 GRID 2641
PERMIT #
MooseRunLISC50OW6
On -Site Water System Permit
MUNICIPALITY OF ANCHORAGE
Development Services Department
On -Site Water & Wastewater Program
4700 Elmore Road, PO Box 196650
Anchorage, AK 99519-6650
Telephone: (907) 343-7904
Permit Number: OSP151355
Tax Code Number: 01516421000
Work Type: Well Renewal
Permit Effective Dates: October 23, 2015 to October 22, 2016
Design Engineer:
Subdivision: MOOSE RUN
Site Legal Address: MOOSE RUN LT 1 G:2641
Owner/Address: SPENCER DAVID WILLIAM &
ANN REEVES 11000 VOSIKOF PLACE ANCHORAGE AK 995076463
Site Mailing Address: 11050 BOULDER CIR, Anchorage
This permit is for the construction of:
N Disposal Field N Septic Tank N Holding Tank
Lot Size in Sq Ft: 101180
Total Bedrooms: 1
N Privy Y Private Well N Water Storage
All construction must be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater
Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80).
3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services
Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either:
A. Open and Close on the same day.
B. Covered, sealed, and heated to prevent freezing.
Received
Issued By
MUNICIPALITY OF ANCHORAGE
Community Development Department Phone: 907-343-7904
Development Services Division Fax: 907-343-7997
On -Site Water & Wastewater Program
ON-SITE SEWER/WELL PERMIT APPLICATION
Parcel I.D. #015-164-21
Property owner(s) David Spencer and Ann Reeves
Mailing address 11000 Vosikof Place
Site address 11050 Boulder Cir
Day phone 306-0077
Legal description (Sub'd., Block & Lot) Moose Run Lot 1 (no block number)
Legal description (Township, Range & Section)
Lot Size 101,180 Sq. Ft. Number of Bedrooms
APPLICATION IS FOR:
(® all that apply)
Absorption Field ❑
Septic Tank
❑
Holding Tank
❑
Privy
❑
Private Well
❑x
Water Storage
❑
APPLICATION IS AN:
TYPE OF DWELLING:
Initial ❑
Single Family (SF) x❑
ADU)
Upgrade El(w/wo
Duplex (D) EJ�
Renewal
Multiple Dwellings ❑
(SF and/or D)
49TH* ..
.........................
THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR: G�-_
The original application contained a slope waiver for the septic system
I certify that the above information is correct. I further certify that this is in accordance with
applicable Municipal Codes. I further certify that the location of the well will not change appreciably from
that shown on the original permit OSPI41289, and that I am signing this
certification in lieu of Lars Spurkland who has passed away.
owner or duthorized agent)
Permit/Rush Fees: Waiver Fees:
Date of Payment:
Receipt Number:
Permit No. OS /P/9 rS1
Original Permit # OSP141289
Permit App_.: :L�t,
Date of Payment:
Receipt Number:
Waiver No.
6v —
bot I
INSTALLED FOOO CALLON SEPTIC TANK
)VEWH LENOrH 50 FW
TRENCH WIDTH 5 FEET
MAX EYCAVAMN DEIprm 1.5 FEET
fi= DEPTH 0.5 FEET
2" INSULATM
25 0 25 50 75 100 125 150
SCALE., V = 50 FT
4' CONTOUR UNES
F"m
ISPURKLANO LNGINLEXIN6;SEP77C SYSTEM ASHUXT
W V 15r/i AVL7Vr1E MOOSE RUN LOT I
ANCH. OK 99501 BILL SPENCER BATE' NOV It? 2014
(907) 279-3916 I I iimg vasmar PLACE NCWRA6E AK 99507 11 ShEE r, B13 GPIB+ 2691
I PERMIT # flSP141889 PIB # 015-164-0 Mbo-swRunL1.SC5aBW6 I
SWING w A B
Sr. ca c
28.r it'
ST. as o
om ca E
28.5' 12.7'
29' 15.5'
I
OF ca F
38.5: 215'
DF. Af.T. G
24.5 34'
Dr. can
31.0' 43.0'
UTIL EASED
SEX,
f
NOTE-- INIS IS NOT A SURVEYED PLAT
WaL & SIMC
LOCA17ONS TAKEN FROM ON-SITE WATER AND WASIr WATER
DEPARTMENT DOCUMENrAWN. ALL LOCAnOff SHOWN ARE
APPROXIMATE.
25 0 25 50 75 100 125 150
SCALE., V = 50 FT
4' CONTOUR UNES
F"m
ISPURKLANO LNGINLEXIN6;SEP77C SYSTEM ASHUXT
W V 15r/i AVL7Vr1E MOOSE RUN LOT I
ANCH. OK 99501 BILL SPENCER BATE' NOV It? 2014
(907) 279-3916 I I iimg vasmar PLACE NCWRA6E AK 99507 11 ShEE r, B13 GPIB+ 2691
I PERMIT # flSP141889 PIB # 015-164-0 Mbo-swRunL1.SC5aBW6 I
Municipality of Anchorage
On -Site Water and Wastewater Program • (907) 343-7904 Page 1 of 3
ON-SITE WASTEWATER INSPECTION REPORT
Permit Number: OSP141289 PID Number: 015-164-21
Dwelling: M Single Family (SF) ❑ Duplex (D) ❑ Multiple (SF and/or D) Project: X New ❑ Upgrade
Name:
BILL SPENCER
ABSORPTION FIELD
❑ Deep Trench N Shallow Trench E] Bed E] Mound
Address
11000 VOSIKOF PL ANCHORAGE AK 99507
M Other
Phone
Number of Bedrooms
Soil Rating
Total depth from original grade
1
0.6 GPD/SF
1.1 Ft.
LEGAL DESCRIPTION
Depth to pipe invert from original grade
0.6 Ft.
Gravel depth beneath pipe
0.5 Ft.
Subdivision Block Lot
MOOSE RUN 1
Fill added above original grade
2-3 Ft.
Gravel length
50 Ft.
Township Range Section
Gravel width
5 Ft.
Beds: Number of Lines
NA
Distance between lines
NA Ft.
SEPARATION DISTANCES
To
Septic
Absorption
Holding
Sewer
Total absorption area
Number of trenches
Dist. between trenches
From
Tank
Field
Lift Station
Tank
Line
250 Ftp
1
1 NA Ft.
Well
>100'
>100'
NA
NA
>251
TANK ■ Septic [IS.T.E.P. ❑ Holding ❑ Other
Manufacturer
GREER
Capacity
1000 Gal.
Surface Water
>100'
>100'
NA
NA
Material
STEEL
Number of compartments
2
Lot Line
>5'
>10'
NA
NA
NA
Foundation
>5'
>10'
NA
NA
LIFT STATION
Manufacturer
Capacity
Curtain Drain
>50'
>50'
NA
NA
Gal.
Pump on level at
Pump off level at
High water alarm at
Remarks
in.
in.
in.
Pump make and model
Electrical Inspections performed by
PIPE MATERIAL House to tank 3034 Tank to 3034
drainfield
Installer
DEAN CONSTRUCTION
Drainfield 3034 CO/MT3034
Inspector LARS SPURKLAND, ANSON MOXNESS
BENCHMARK (Assumed elevation)100 8
Inspection 1u 9/18/14 9/18/14 -
Location and description
2nd
da
3" 9/18/14 4'"
BOTTOM SIDING NW CORNER
COMMUNITY DEVELOPMENT DEPARTMENT APPROVAL
Engir>&x'sStamp
Conditional Approval: Date
s
i 4, li ,
41
i'e A 14
AKAe r1
s',tio
l�I<Fp Ij�11y,.•���
Approved Date
IL� F S IONP�
Inspection Report3=1-12.doc
PROPOSE
M�
bot I n,pE
INSTALLED I -BEDROOM SEPTIC SYSTEM
INSTALLED 1000 GALLON SEPTC TANK
� TRENCH LENGTH 50 FEEL
TRENCH WIDTH 5 fEET
MAX EXCAVATION DEPTH 1.5 FEET
/ ROCK DEPTH 0.5 FEET �y
j 2' INSULATION
SWING TIES A B
S T. C.O. C
2&7'
11'
S.T. C. 0. D
2&5'
127'
DBL. C.O. £
29'
15.5'
DF. C.O. F
38.5'
25.5'
J Of. M. T. G
24.5'
34'
DF. C.O. H
31.0'
43.0'
I
�i
r �
H
SL0'L
1011 UT1L EASE/
- - T
/N
NOTE.• THIS IS NOT A SURVEYED PLAT. WELL & SEPTIC
LOCATIONS TAKEN FROM ON-SlT£ WATER AND WASTE WATER
DEPARTMENT DOCUMENTATION. ALL LOCAAONS SHOWN ARE
APPROXIMATE.
25 0 25 50 75 100 125 150
SCALE 1' = 50 FT
BDRM
SFR
4' CONTOUR LINES
SPURKLAND ENGINEERINGSEPTIC SYSTEM ASBUXT
203 V 15TH AVENUE MDOSE RUN LOT 1
ANCH. AK 99501 BILL SPENCER DATE, NOV 10 2014
(907) 279-3916 11 11000 VBSIK17F PLACE ANCHORAGE AK 99507 SHEET, 2/3 GRID: 2691
PERMIT # OSP141289 PID # 015-164-21 MooseRunLLSC5ABV6
TH
Wide Trench.,
5' Wide
50' Long
1.5' Max. Depth
0.5' Sewer Rock
2' Insulatlon
EV
EV=92.1
OH £LEV
TN £LEV
NO SCALE
Trench Elevation (TyP)
Cleanouts
Monitor
Silt Barrier
2' Insulation
0.5 ft of Septic Rock
DOUBLE
CLEANOUTS
BENCH MARK BOTTOM SMNO NW cORNER
ASSUMED ELEVATION 100 FEET
ELEV.=98.6'
1000 GALLON SEPTIC
FOUNDATION
CLEANOUT
94.6'
SPURKLAND
SPURKLAND ENGINEERING MOOSE RUN LOT I SEPTIC SYSTEM ASBUILT I
203 W 15TH. AVENUE
(NCH. AK. BILL SPENCER BATE, NOV 10 20)4 (907) 279-39163916
11 I1000 VOSIKTIF PLACE ANCHORAGE AK SHEET.• 3/3 GRID 2641
PERMIT # OSP 141289 PID #015-164-21 MOOSERUNLLB3-ASB.BW6
On -Site Water & Wastewater System Permit
MUNICIPALITY OF ANCHORAGE
Development Services Department
On -Site Water & Wastewater Program
4700 Elmore Road, PO Box 196650
Anchorage, AK 99519-6650
Telephone: (907) 343-7904
Permit Number: OSP141289
Tax Code Number: 01516421000
Work Type: WellSeptic Initial
Permit Effective Dates: August 28, 2014 to August 28, 2015
Design Engineer: SPURKLAND ENGINEERING
Subdivision: MOOSE RUN
Site Legal Address: MOOSE RUN LT 1 G:2641
OwnerlAddress: SPENCER DAVID WILLIAM &
ANN REEVES 11000 VOSIKOF PLACE ANCHORAGE AK 995076463
Site Mailing Address: 11046 Boulder CIR, Anchorage
This permit is for the construction of:
Y Disposal Field Y Septic Tank N Holding Tank
All construction must be in accordance with:
Lot Size in Sq Ft: 101180
Total Bedrooms: 1
N Privy Y Private Well N Water Storage
1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater
Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80).
3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services
Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either:
A. Open and Close on the same day.
B. Covered, sealed, and heated to prevent freezing.
Received B}
Issued By:
Municipality of Anchorage
P.O. Box 196650 • 4700 Elmore Road
Anchorage Alaska 99519-6650 • (907) 343-7904 • Fax (907) 343-7997
http://www.muni.org/Onsite
Development Services Division
On -Site Water and Wastewater Program
gent i
� r
a
Y �
Department
**** VARIANCE/WAIVER REVIEW ****
Waiver#: OSP141365 COSA#:
PID#: 015-164-21
Legal Description: Moose Run Lot 1
Engineer: Spurkland Engineering
Applicant: Bill Spencer
Permit#: OSP141289
Your request for a waiver of the required 50 feet horizontal separation from the absorption field
to the excessive slope has been approved. The approved separation distance is 35 feet for the
reserve field and 41 feet for the primary field.
This waiver approval applies to the proposed absorption field only. Any future upgrade to the
on-site wastewater disposal system will require all separation distances be met or another
approval from this department.
❑ The affected adjacent property owner(s) have been given a 7 day notice regarding this
waiver.
❑ Notarized letter(s) of nonobjection have been received from the owner(s) of the affected
adjacent property.
® Adjacent properties are not affected by this waiver.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . I
Waiver is Granted: X Waiver is not Granted:
Date: S Z,S O Approved by: ka, t/
Name of Reviewer
...........................................................� .................
**** VARIANCEMAIVER REVIEW ****
MUNICIPALITY OF
Community Development Department
Development Services Division C6)
On -Site Water & Wastewater Program
ANCHORAGE
Phone: 907-343-7904
Fax: 907-343-7997
ON-SITE SEWER/WELL PERMIT APPLICATION
Parcell.D. 015-164-21
Property owner(s) BILL SPENCER Day phone
Mailing address 11000 VOSIKOF PL, ANCHORAGE AK 99507
Site address BOULDER CIRCLE
Legal description (Sub'd., Block & Lot) MOOSE RUN LOT 1
Legal description (Township, Range & Section)
Lot Size Sq. Ft. Number of Bedrooms
APPLICATION IS FOR:
APPLICATION IS AN: TYPE OF DWELLING:
(® all that apply)
Absorption Field
0
Initial Fx1 Single Family (SF)
0
(w/wo ADU)
Septic Tank
ElUpgrade
F-1Duplex
(D)
71Holding
Tank
F-1Renewal
F]Multiple
Dwellings
❑
Privy
❑
(SF and/or D)
Private Well
Q
m1h 91TU
Water Storage
❑
JUL 3t [ A
THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR:
Distance:
I certify that the above information is correct. I further certify that this is in accordance with
Permit/Rush Fees: 51,A — fi Z-1 -(�
Date of Payment: _713111q
Receipt Number: 655 -ft
Permit No. Q`Je1417-d 1
Permit App_9-1 -1 2.doc
iA1a
Iver Fees: 2,15
Date of Payment: 8,1a-jKr(1
Receipt Number: b15
Waiver No. r),'p 13 b5
Environmental Consulting and Design
SEPTIC SYSTEM DESIGN
MOOSE RUN LOT 1
Municipality of Anchorage July 29, 2014
Development Services Department
On Site Water and Wastewater Program
4700 Elmore Road
Anchorage, Alaska 99519
Subject: Well & Septic System Installation Permit
11000 Vosikof Place
Ladies and Gentlemen:
I am writing to request a well and septic system installation permit for the above referenced
property. The proposed system will serve a I -bedroom single-family residence. Soil logs,
design calculations, a site plan, design drawings and construction specifications are enclosed for
your review.
Design Cates: Groundwater observed at a depth of 9 feet below ground surface
(7/29/2014).
Soil Ratings: From TH #1 7/24/14
2.5 min/in = 1.2 gal per sq.£t/day
From TH #2 7/24/14
28 min/in = 0.6 gal per sq.ft./day
From TH #2 7/24/14
23 min/in = 0.6 gal per sq.ft./day
No. of Bedrooms
Required Area per Bedroom: 15010.6 =250.ft.
Total area required: 250 x 1 = 250 sq.ft.
System: We are proposing a 1000 gallon septic tank followed by a wide trench absorption field.
The absorption field will be 50 feet long and 5 feet wide and contain 0.5 feet (250 sq.ft.
effective) of sewer rock.
Soils: Test holes were excavated on July 22"d,2014. See the attached soil logs. Ground water
Monitoring will continue through construction of the septic system. Groundwater was observed
203 West 15th Avenue Suite 203, Anchorage, AK 99501, Phone: (907) 279-3916
Fax: (866) 354-1597, Lspurkland@gci.net
Environmental Consulting and Design
at a depth of 9feet below ground surface in Test hole 41. Test Hole #2 was dry. Test hole #3 was
excavated so that an additional percolation test could be conducted. It had a total depth of 5 feet,
ground water was not observed.
Surface Water: There are no surface waters within one hundred feet of the proposed septic
system upgrade.
Topography: The ground level slopes down towards the west at 40% above the proposed septic
location, 10-15% at the area where the proposed septic system location, and drops off at 45%
approximately 40 feet from the location of the reserve field and 65 feet from the proposed drain
field.
Waivers: We are requesting slope waivers for the primary and reserve sites. See attached
documentation.
Well: The proposed well location is in the southeast corner of the lot and will not impact the
usable area of the lots to the east or south.
The installation of this well and septic system will not prevent wells and septic systems from
being installed on the adjacent lots. The proposed septic system will not change the general
slope of the area. Ponding and/or concentration of surface runoff will not result from this
installation.
If you have any questions or concerns, please contact me at 279-3916.
Sincerely,
(ItaS
Lars Spurkland, P.E.
Civil Engineer
203 West 151h Avenue Suite 203, Anchorage, AK 99501, Phone: (907) 279-3916
Fax: (866) 354-1597, Lspurkland@gci.net
i
It
I � �
GAmv-t Lot 2
'II
I I S. D
12 *I i E R U:"N
' Loi 1
I I
1'
DI I
I l �
POND
IIS' I O
OS —
I' al
I W
S I
I Y6
I lT
I I
1
I1
f
— — 10.' UTLL EASE
14
Septk�
(;Aren
/i 15 T+CLINE �; Lot 16
7�/7�/% I 4' CONTOUR LINES
NOTE. THIS IS NOT A SURVEYED PLAT. WELL k SEPTIC
LOCATIONS TAKEN FROM ON—Siff WATER AND WASTE WATER
DEPARTMENT DOCUMENTATION. ALL LOCATIONS SHOWN ARE
APPROXIMATE.
50 0 50 100 150 200 250 300
SCALE; 1' = 100 FT.
J
III
I Lot 32 pR]
I gpULDER �
I I
II
SLott 31
SPURKLAND ENGINEERING MUUbP,' JYUN LUT' I SEPTIC SYSTEM DESIGN
203 V 15TH AVENUE BILL SPENCER DA TE.- MAY 28, 2014
ANCH AK. 99501
(907) 279-3916 11 11000 V17SIKOF PLACE SHEET, 1/3 GRID, 2641
PERMIT If OSP141XXX PID # 015-164-21 MOOSPRUnLISCIDODV6
U N S
E �
Lot 1
INSTALL 1 -BEDROOM SEPTIC SYSTEM
INSTALL 1000 GALLON SEPTIC TANK
TRENCH LENGTH 50 FEET
TRENCH WIDTH 5 FEET
MAX EXCAVATION DEPTH 1.5 FEET
ROCK DEPTH 0.5 FEET
2" INSULATION
COVER 1 FEET (MIN.)
10' UTIL EASE
N
s, �;f
NOTE. THIS IS NOT A SURVEYED PLAT. WELL & SEPTIC
LOCATIONS TAKEN FROM ON-SITE WATER AND WASTE WATER
DEPARTMENT DOCUMENTATION. ALL LOCATIONS SHOWN ARE
APPROXIMATE.
25 0 25 50 75 100 125 150
SCALE; 1' = 50 FT
PROPOSED l�
4' CONTOUR LINES
SPURKLAND ENGINEERING I I MOOSE RUN LOT 1 I I SEPTIC SYSTEM DESIGN
203 V 157H. AVENUE BILL SPENCER DATE.., JULY 24 2014
ANCH. AK. 99501
(907) 279-3916 11000 VOSIKOF PLACE ANCHORAGE AK 99516 SHEET., 213 GRID+ 2641
PERMIT H L7SP141XXX PID If 015-164-21 MooseRunLLSC50.DVG
Wide Trench-
5' V/de
50' Long
IS' Max. Depth
0.5' Sewer Rock
2' Cover
2' Insulation
NO SCALE
Trench Elevation (TyP)
CI E L nO",-,-s
t5
Monitors
Silt Barrier
2` Insul a on
0.5 Ft of Septic Rock
DOUBLE
CLEANOUTS
FOUNDATION
CLEANOUT
1000 GALLON SEPTIC
SPURKUIVD ENGINEERINGI I MOOSE RUN LOT 1 I I SEPTIC SYSTEM DESIGN
203 V 15TH AVENUE BILL SPENCER DATE,- JULY 24 2014
ANCH, AK, 99501
(907) 279-3916 11000 VOSIKOF PLACE ANCHORAGE AK SHEER 3/3 6RID,- 2641
PERMIT # OSP 141XXX PID #015-164-21 MOOSERUNLLD3DV6
CD
0
N
Toy--.. to d
♦AV
FU
m�
z
z
3 V= cz
Wo
D o e D o o m
� Na
�04>, 2
p
c"
n
r
rfi
Cl) 0
cn
CD
c0 _ _...
o ti/
\/ 2
l CR
o, I
03
n
A
tF
c
O
Z
N
Spurkland Engineering
203 W. ISth Ave. Ste. 202A
Anchorage, AK99501
TEST HOLE j __I
DEPTH
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
SOIL LOG AND PERCOLATION TEST
SOIL DESCRIPTION DA 7E._I/2Z,LLt_____
ORGANICS WAS GROUNDWATER OBSERVED: __Yes
IF YES, AT WHAT DEPTH.• 9
AFTER MONITORING PERIOD.
Silly Gravel DATE OBSERVED: __—71a1jj-
(GM) PERCOLATION TEST.•
Sill
NO
FILL
DATE I GROSS TIME
NET TIME
DISTANCE
DROP
9.625
7 24 14 1:27
pm
0 min.
9.125"
1:37
pm
10 min
14.500'
4.875"
9.000
1.47
pm
10 min
13.438
4.313
6.438"
1:57
pm
10 min
13.625
4.625
6.438
1:07
pm
10 min
13.063
4.625
9.313
2.17
pm
10 min
13.188
4.750
2:27
pm
10 min
14.000
4.688
Gravelly Silt PERCOLATION RATE. • 2.5 minutes/ inch
(ML, GO PERC HOLE DIAMETER: 6 inches
TEST RUN BETWEEN 1.5 FT AND ? __ FT
SITE PLAN:
N
SEE ATTACHED SITE PLAN
NOTES PR£=SOAKED. ML LAYER PRE SOAKED FOR 4 HOURS. IT DRAINED AT A RATE OF____
APPROXIMATELY 90 MIN. INCH INDICATING THAT IT IS NOT IMPREMEABLE.
PERFORMED BY. Anson Moxness. 1, Lars Sourkland P.E. CERTIFY THAT THIS TEST WAS PERFORMED IN
ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE.
SPURKLAND ENGINEERING A100SE RUN LOT 1 SOIL LOG PERCOLATION TEST
203 V 15TH, AVENUE
ANCH. AK. 99501 BILL SPENCER DATE, JULY 24 2014
FY07`I 271;0-jyl& 11000 VU.Y1Ktr PLACE' ANL`HaNAGt AK GXID X 21541
PERMIT # PID # 015-164-21
Spurkland Engineering
203 W. 15th Ave. Ste. 202A
Anchorage, AK99501
TEST HOLE j --2—
DEPTH
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
SOIL A
LOG AND PERCOLATION TEST
rou o
WAS GROUNDWATER OBSERVED. _No_—
IF YES, AT WHAT DEPTH:
AFTER MONITORING PERIOD: _DRY__
DATE OBSERVED: -----712911A-
PERCOLATION TEST.•
FILL
DATE I GROSS TIME
NET TIME
DISTANCE
DROP
4.750'
7124114 1:24 PM
0 min.
4.313'
1:54 pm
30 min
6.250
1.500
4.438
2.•24 pm
30 min
5.313
1.000
1:54 pm
30 min
5.500
1.063
PERCOLATION RATE. 28 minutes/ inch
PERC HOLE DIAMETER: 6 inches
TEST RUN BETWEEN —L- FT AND __ 2_5 FT
SITE PIAN.•
N
SEE ATTACHED SITE PLAN
VOTES: PRE-SOAKED ___�________
PERFORMED BY: Anson Moxness. 1, Lars Spurkland P.E. CERTIFY THAT THIS TEST WAS PERFORMED IN
ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE.
SPURKLAND ENGINEERING MOOSE RUN LOT I SOIL LOG PERCOLATION TEST
203 W 15TH AVENUE
ANCH. AK. 99501 BILL SPENCER DATE JULY 24 2014
(907) 279-3916 11000 V17SIK17F PLACE ANCHORAGE AK GRID #.- 2641
PERMIT # PID # 015-164-21
Spurkland Engineering
203 W. 156 Ave. Ste. 202A
Anchorage, AK99501
TEST HOLE # _ 3
DEPTH
1
2
3
4
5
6
7
8
9
f0
11
11
13
14
15
16
17
18
19
20
SOIL LOG AND PERCOLATION TEST
SOIL DESCRIPTION DATE._1122,L14-__—
ORGANICS WAS GROUNDWATER OBSERVED: _
IF YES, AT WHAT DEPTH. _
AFTER MONITORING PERIOD:
DATE OBSERVED:
Gravelly Slit PERCOLATION TEST.-
(ML,GM)
No
FILL
DATE I GROSS TIME
NET TIME
DISTANCE
DROP
6.563"
7 24 14 1:24 pm
0 min.
7.000'
1:54 pm
30 min
7.875
1.500"
7.500
1:14 pm
30 min
8.125
1.125
2:54 pm
30 min
8.688
1.188
PERCOLATION RATE. 25 minutes/ inch
PERC HOLE DIAMETER: 6 inches
TEST RUN BETWEEN ? FT AND 2.5 FT
SITE PLAN:
N
SEE ATTACHED SITE PLAN
NOTES. • PRE—SOAKED
PERFORMED BY. Anson Moxness. I, Lars Spurkland P.E. CERTIFY THAT THIS TEST WAS PERFORMED IN
ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE.
SPURKLAND ENGINEERING HOOSE RUN LOT 1 SOIL LOG PERCOLATION TEST
203 W 15TH, AVENUE
ANCH. AK. 99501 BILL SPENCER BATE,
JULY 24 2014
(907) 279-3916 11000 VVSIKOF PLACE ANCHORAGE AK GRID N+ 2641
PERMIT # PID # 015-164-21
Page 1 of 1
Wockenfuss, Deborah M.
From:
Jones -Vogel, Nicole K.
Sent:
Tuesday, August 19, 2014 3:47 PM
To:
'Lars Spurkland'
Cc:
Wockenfuss, Deborah M.
Subject: RE: Septic Permit- Wetlands Delineation- Moose Run Lot 1
Hi Lars,
Thanks for the call today and discussing the septic plans/development plans for Moose Run Lot 1. Based on a
site visit in the area earlier this summer, the wetlands appear to be located at the base of the slope and continue
west to the western property line. Since your proposed development is on the slope, it is unlikely that you will
need a wetland delineation. You may wish to consider contacting the Corps and requesting a Pre -Jurisdictional
Determination (PJD); a PJD can be done via desktop analysis. The Corps can be reached at 907-753-2712.
Deb, I do not foresee any wetland impacts with this proposed development. If the site plan is modified and the
development moves down slope, then it may be necessary to coordinate with the Corps for a PJD (or a JD).
If there are any questions, please let me know
Thanks,
Nicole
Nicole K. Jones -Vogel, Associate Planner
Planning Division -Community Development Department
Long -Range Planning Section
P.O. Box 196650
Anchorage, AK 99519-6650
907.343.7922
907.249.7726 FAX
Jones-VogeINK@a muni -or
Web: www.muni.org/Planning-
From: Lars Spurkland [mailto:lspurkland@gci.net]
Sent: Tuesday, August 19, 2014 3:05 PM
To: Jones -Vogel, Nicole K.
Subject: Septic Permit- Wetlands Delineation- Moose Run Lot 1
Nicole,
I have attached a site plan and area map for the proposed septic system at Moose Run Lot 1. If you have any
questions. Please give me a call at 279-3916.
Thank you,
Lars Spurkland
Spurkland Engineering
8/27/2014