On-Site Water & Wastewater System Permit
OSP141390
05128102000
WellSeptic
MUNICIPALITY OF ANCHORAGE
Development Services Department
On-Site Water & Wastewater Program
4700 Elmore Road, PO Box 196650
Anchorage, AK 99519-6650
Telephone: (907) 343-7904
Initial
Permit Effective Dates: September24, 2014 to September24, 2015
Design Engineer: MILLER MITCHEL R & SHANNON
Subdivision: T15N R2W SEC 25
Site Legal Address: T15N R2W SEC 25 LT 30 G:0753
Owner/Address: MILLER MITCHEL R & SHANNON
16234 CARLISLE ST EAGLE RIVER AK 995779303
Site Mailing Address: 16234 CARLISLE ST, Eagle River
Lot Size in Sq Ft: 96268
Total Bedrooms: 3
This permit is for the construction of:
Y Disposal Field Y Septic Tank N Holding Tank N Privy Y Private Well N Water Storage
All construction must be in accordance with: 1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater
Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80).
3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services
Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either:
A. Open and Close on the same day.
B. Covered, sealed, and heated to prevent freezing.
/
Received//~BY:
Issued By?,""~,//~,,~/I/
Date: ////~
Date: q/~//~
MUNICIPALITY OF ANCHORAGE
Community Development Department
Development Services Division
On-Site Water & Wastewater Program
Phone: 907-343-7904
Fax: 907-343-7997
ON-SITE SEWER/WELL PERMIT APPLICATION
Parcel I.D. 051 281 02 000
Property owner(s) Mitch and Shannon Miller
Mailing address 16234 Carlisle St., Eagle River 99577
Day phone 351-4572
Site address 16234 Cadise St.
Legal description (Sub'&, Block & Lot) N/A
Legal description (Township, Range & Section) T15N R2W SEC25 LT30
Lot Size 96,268 Sq. Ft. Number of Bedrooms 3
APPLICATION IS FOR:
([~ all that apply)
Absorption Field []
Septic Tank []
Holding Tank []
Privy []
Private Well []
Water Storage []
THIS APPLICATION
N/A
APPLICATION IS AN:
TYPE OF DWELLING:
Initial
Upgrade
Renewal
[] Single Family (SF)
(w/wo ADU)
Duplex (D)
Multiple Dwellings
INCLUDES A VARIANCE /
Distance:
I certify that the above information is correct. I further certify that this is in accordance with
applicable Municipal Codes.
(Signature of property owner or authorized agent)
Permit/Rush Fees: ~'t.~'"'
Date of Payment:
Receipt Number: (~ ( '5-(~ ~-I
Permit No.
Waiver Fees:
Date of Payment:
Receipt Number:
Waiver No.
Permit App_J- :- :2.Cc
Mitch Miller, PE
16234 Carlisle St
Eagle River, AK 99577
September 12, 2014
Municipality of Anchorage
Development Services Department
On-Site Water and Wastewater Program
4700 East Elmore Road, Anchorage AK 99519
Subject:
T15N R2WSEC25 Lot 30
Proposed Well and Septic System Replacement
To whom it may concern,
My wife and I are the owners of this property and we intend on installing a new septic system
to replace our current system that is undocumented with the municipality. I am a registered
civil engineer in Alaska and will be providing the design, inspection and documentation for the
new system.
Our intent is to subdivide this property in the near future. During the initial stages of
subdividing it came to our attention that the existing septic system is not documented with the
MOA. In order keep the subdivision process going and considering the age of the existing tank,
we have opted to install a replacement system. The new tank will be located in approximately
the same location as the existing tank, as shown on the attached site plan. In preparation to
subdividing we also intend on installing a new well for the existing house as the current well will
ultimately be located on the newly created lot. We are requesting a permit be issued for the
construction of a new well and septic system to serve the existing home. The attached area
map, site plan and back up documentation depict the locations of the proposed improvements
as well as the surrounding wells and septic systems.
The ground surface of our lot and the surrounding lots is generally flat. In the area of the
proposed septic there is a slight 0-1% slope to the southwest. The drainage pattern will not be
altered as a result of this work. The south and east ROW / utility easement will be located by a
registered land surveyor prior to the beginning of work on the proposed well and septic system.
The test holes advanced in the vicinity of the septic system showed organic silty sand down to
approximately 1 ft followed by silty sand and sandy gravel down to 4.5 feet bgs. Poorly graded
sandy gravels / gravelly sands were found between 4.5 feet and 17 feet (BOH). The percolation
rate of the soil was determined to be 1-5 minutes per inch. No groundwater was found during
the excavation of the test holes nor during the monitoring period. An application rate of 1.2
gallons per day per square foot was used in the design of the disposal field. We are proposing
to place new 1,250-gallon septic tank and a 40-ft by 2.5-ft wide by 6.5-ft effective depth
absorption trench to treat and dispose of the effluent generated in the house. The elevation of
the distribution line and the new tank will be approximately 4.5 feet below finished grade. The
trench will be excavated down to approximately :[1 feet, backfilled with washed sewer rock and
capped with a separation geotextile to prevent comingling of imported rock and fill.
The new septic system will be located more than 100 feet from all wells and surface water.
I am unaware of any adverse impacts this installation would have on adjacent well or septic
systems. If you have any questions, please contact me at 35:[-4527. Thank you for your
assistance.
Sincerely,
Mitch Miller, PE
EX,ST,~,C ~ 16324 ~i.~l~-St.' ' I,
'~74 Hillcres Dr. , : ' ~a'rl~s']~
' 16305 SE '
b
EXISTfNG 16234 Carlisle St. ,' ,,
~fiPIl~-'¢¢ LT30, SEC 25,~15N, R2W ,
~ ~XISTI~G ~00 F ,
ABANDONED ~ / ' ~' ,
I/
,SEPTIC ~ -
/ ,' ,LOCATED . ' ,.. , 16231 Carlisle St.
1622~?hi~*~.. St. p~TIC &..,., '..'~,~ ', , x~00FT pS~MEn*~D~;~MTILITY
EXISTING .... -~; . ,. 16203 Carlisle St.
,SepT~C~I, ..... ~ .', ¢
= "'1 " ................... ":--' ' "
O EXISTING
SEPTIC
16128 Carlisle St.
, 16177 Carlisle St.
Sh~ms St. / ,
/ 100 F x~ ,
' "
, WELL ,: *' 49 ~ ~ '.
,,,, ,, ,,',
', ', -' " %~-. c[-~oo~ ..~
, SCALE 1" = 100' ,,
I
AREA MAP FOR PROPOSED WELL AND SEPTIC
16234 CARLISLE ST.
EAGLE RIVER, AK 99577
T15N, R2W, SEC 25, LT 30
LU
N89° 57'W 287.56+/-
DESIGN CRITERIA: ·
4 BDRM = 600 GPD
SOILS = 1.2 GPD/SQFT
600/1.2 = 500 SQFT RE~
DRAINFIELD DESIGn/r
11.0 FT DEEP
6.5 FT EFFECTIV~
2.5 FT WIDE
268
TI~ WELL
100 FI TO REMAIN TO
t ~ SERVE FUTURE
',,. ' HOUSE
268 FT
268 FT
GARAGE t GR~4EL DRIVEWAY
D~
16234 CARLISLE ST.
96,268 S 21 FT
SEPTIC TANK
268 FT
TH1
.~.. W/MT
...'.. TH2 ,~
SEWEC~LINE
DECK
100 FT
SYSTEM
EDECOMISSIONED
RESERVE SITE
..................................................... -..- .-
SCALE 1" = 40' ~ ) FT ROW AND
CONTOUR INT. = 4'
,50 FT ROW AND
UTILITY EA.'
N89° 56'W 289.21+/-
SITE PLAN FOR PROPOSED WELL AND SEPTIC
16234 CARLISLE ST.
EAGLE RIVER, AK 99577
T15N R2W SEC 25 LT 30
T15N R2W SEC25 LT30
DESIGN FOR INITIAL AND RESERVE DISPOSAL FIELDS
DESIGN CRITERIA
4 BDRM = 600 GPD
SOILS APP. RATE = 1.2 GPD/SF
600/1.2 = 500 SF REQ'D
SYSTEM DESCRIPTION
DEEP TRENCH SYSTEM
1,250 GAL SEPTIC TANK
6.5 FT EFF. TRENCH DEPTH
Separation
Geotextile
4-inch
Perforated PVC --
(holes down)
RockDrainfield
DESIGN
600 GPD/1.2GPD/SF = 500 S~
Onsite
Backfill
2.5 FT WIDE
TRENCH
4FT
6IN
6.5 FT
500 SF/13 SF/LF = 38.5 LF TRENCH LENGTH (MIN)
CONSTRUCT A TRENCH 40' L x 2.5'W x 6.5'D (11' TOTAL)
PROVIDE 4' OF COVER OVER DISTRUBUTION L1NE AND TANK
LOCATE SYSTEM AS SHOWN ON SITE PLAN
PIPE MATERIALS SHALL BE:
PVC PIPE ASTM D3034, F789
ABS PI~E ASTM D2751', D2661
HDPE PIPE ASTM F810*
*DO NOT USE AS CLEAN OUTS NOR STAND PIPES
NOTES:
GRADE AREA OVER TRENCH TO DRAIN AWAY
MIN. 6 FT SEPARATION FROM BEDROCK
MIN. 100 FT SEPARATION FOM WELLS IN THE AREA