Loading...
HomeMy WebLinkAboutTALUS WEST #1 BLK 5 LT 19Talus West #1 Block 5 Lot 19 #015-202-39 Permit Number: Tax Code Number: Work Type: On-Site Wastewater Disposal System Permit OSP141161 01520239000 Septic MUNICIPALITY OF ANCHORAGE Development Services Department On-Site Water & Wastewater Program 4700 Elmore Road, PO Box 196650 Anchorage, AK 99519-6650 Telephone: (907) 343-7904 Upgrade Permit Effective DateS: October 02, 2014 to October 02, 2015 Design Engineer: PANNONE ENGINEERING SERVICE Subdivision: TALUS WEST #1 Site Legal Address: TALUS WEST #1 BLK 5 LT 19 G:2736 Owner/Address: CHALK KENNETH H & YOKO K 4311 SUNSTONE CIRCLE ANCHORAGE AK 995162221 )artment Site Mailing Address: 4311 SUNSTONE ClR, Anchorage Lot Size in Sq Ft: 18000 Total Bedrooms: 4 This permit is for the construction of: Y Disposal Field Y SepticTank N Holding Tank N Privy N Private Well N Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80). 3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either: A. Open and Close on the same day. B. Covered, sealed, and heated to prevent freezing. Special Provisions: A sieve gradation analysis shall be completed on the SW/GM soil layer found in Test Hole 1 between 13 feet and 17 feet. If the analysis results require changes to the design, the absorption field shall be completed in accordance with the approved required change order. Analysis results shall be submitted with the final inspection report. t '/ Municipality of Anchorage P.O. Box 196650 · 4700 Elmore Road Anchoraqe, Alaska 99519-6650 · (907) 343-7904 · Fax (907) 343-7997 http:l/www.muni.orq/Onsite Development Services Division On-Site Water and Wastewater Proqram **** VARIANCE/WAIVER REVIEW **** Waive~: OSP141445 COSA#:__ Permit#: OSP141161. PID#: 015-202-39 Legal Description: Talus West #1, Block 5, Lot 19 Engineer: PES Applicant: Kenneth &Yoko Chalk Your request to use the proposed wastewater code for designing the proposed absorption field has been approved. Additionally, your request to waive the proposed wastewater code requirement for additional test holes 20 and 40 feet down gradient from the absorption field has been approved. This waiver approval applies to the proposed absorption field only. [] The affected adjacent property owner(s) have been given a 7 day notice regarding this waiver. [] Notarized letter(s) of non-objection have been received from the owner(s) of the affected adjacent property. [] Adjacent properties are not affected by this waiver. Waiver is Granted: X Waiver is not Granted: ( { /t/,¢ Nhme of Reviewer MUNICIPALITY OF ANCHORAGE Community Development Department Development Services Division On-Site Water & Wastewater Program Phone: 907-343-7904 Fax: 907-343-7997 ON-SITE SEWER/WELL PERMIT APPLICATION Parcel I.D. 015-202-39 Property owner(s) KENNETH & YOKO CHALK Day phone Mailing address 4311 SUNSTONE ClR, ANCHORAGE, AK,99516 Site address 4311 SUNSTONE CIR, ANCHORAGE, AK, 99516 Legal description (Sub'd., Block & Lot) TALUS WEST #1 BLK 5 LT 19 Legal description (Township, Range & Section) Lot Size 18,000 Sq. Ft. Number of Bedrooms 4 APPLICATION IS FOR: ([i;~ all that apply) Absorption Field [] Septic Tank [] Holding Tank [] Privy [] Private Well [] Water Storage [] APPLICATION IS AN: TYPE OF DWELLING: Initial Upgrade Renewal [] Single Family (SF) (w/wo ADU) Duplex (D) JUN 0 ~ Z014 THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit/Rush Fees: '~'~ -- Date of Payment: Receipt Number: - ~"~ Permit No. 0~/~ I1~ Waiver Fees: $6:~/~ Date of Payment: Receipt Number: C)~ ~¢~-C_.~ Waiver No. (.~P[/'Ttt/q ~/,~'' Pannone Engineering Services LLC 5teven R. Pannone, Principal Registered Professional Engineer E-maih steve(~panengak.com September 30, 2014 Municipality of Anchorage Development Services Department On-Site Water & Wastewater Program 4700 Elmore Road P. O. Box 196650 Anchorage, Alaska 99519 Subject: Talus West Addition No.l, Block 5 Lot 19 Septic System Permit Request Ladies and Gentlemen: I am writing to request a permit to install an upgrade to the existing septic system be issued for this property. The proposed upgrade system will serve an existing four (4) bedroom house. Currently the existing field is in groundwater. The proposed system will utilize a 1500g S.T.E.P tank, an Orenco AX20 treatment pod and an auxiliary lift station. We propose using and engineered fill beneath the proposed drainfield to obtain separation to ground water and to convey the treated effluent to a soil layer that can accept the effluent. This and the surrounding developed lots are served by private wells. There are no wells on surrounding lots within 100 feet of this system. 1. Soils. We performed a single test hole on May 13, 2014. The soils from two to thirteen feet were blue till gravelly silt that has a percolation rate of 1500 mpi, which is considered an impermeable soil. The soil below thirteen feet (13') was silty sands and gravels with an apparent faster then i MPI percolation rate. Ground water seepage was observed at a depth of 12 feet during the excavation of this test pit. The groundwater was monitored on May 20, 2014 at a depth of six and a half feet {6.5') below the ground level. It is my opinion, based on the results of the soils investigation and percolation tests performed and overall soils appearance; an application rate of 6 gallons/day/square feet should be used for a category III wastewater system. 2. Soil Absorption System Design. a. See Sheet 2 of the design package. 3. Surface Water: There is no surface water within 100 feet of the proposed septic tank and drain field. The proposed drain field upgrade will maintain at least 100 feet from all surface water and drainage ditches. 4. Topography: The existing topography slopes from the north to south at varying slopes from east to Mailing: P.O. Box 100217, Anchorage, AK 99510-0217 Physical: 332 East Manor, Anchorage, AK 99501 Telephone: (907) 272-8218 FAX: (907) 272-8211 Page 2 of 3 west but at approximately 7-8% in the area of the proposed drain field. There are no steep slopes within 50' of the proposed drain field. 5. Waiver Request for use of Engineered Receiving Soil (ERS). I am requesting a waiver to the 1992 Code to use the proposed Code Update Section of Engineered Receiving Soils (ERS). Below I will detail my request justifying the use of ERS: a. One test hole was excavated by PES in 2014. The soils log is attached. Seepage was noted at a depth of 12 feet during the excavation of the test pit. Ground water was monitored for seven days. Ground water stabilized at a depth of 6.5 feet below ground surface. b. This design proposes to use MoA Type II classified fill. This interface will be approximately nine feet (9') in depth and will be compacted to approximately 80 percent to allow free flow of the effluent through it into the native soil using MoA Waste Water Code application rates. The infiltration area of the interface between the ERS and the in-situ soil was based on the I to 5 minute per inch percolation rate of the in-situ receiving soiI. Atwo foot thick filter sand layer will be placed over the MoA Type II material to act as an interface between the SAS and ERS. c. The SAS is sized assuming a percolation rate of the ERS soil, assumed 1-5 MPI, which gives an application rate of 6 GPDSF. d. The system will protrude above the ground surface. The cover of the system will produce a mound, which will have at a minimum, three to one side slopes and six inches of organically rich soil to promote the growth of vegetatiom e. Shallow Ground water was observed in the test hole. Steps need to be taken to protect this shallow ground water from contamination with sewage effluent. These steps include the use of advanced wastewater treatment system to ensure a high quality effluent and maintaining at least four feet of vertical separation from the highest ground water and the bottom of the drain field (our design is calling for 4.5 feet vertical separation.) Surrounding well logs show well depths in the 50 to 70 feet range. Static water levels are measured in the 30 foot depth below ground level range. This indicates that this shallow ground water is not the same aquifer that supplies water to the local wells (if they were the same aquifer, the static water levels would be similar and that there must be a confining layer between the depth of 30 feet and 50 feet below ground level.) So breaking through the blue clay layer at minus thirteen feet should not affect the drinking water aquifer. f. Waiver request to requirement for two additional test holes down gradient: PES researched existing soils information (record soil logs and well logs on file with the MoA) from three lots down gradient of the proposed ERS system. PES found detailed soils logs and well logs down gradient. The sand layer continues in varying thicknesses down gradient. See attached well and soils logs. g. PES requests that we perform a sieve analysis of the underlying material {the GM/SM material at -13 feet at the time of construction. 6. Drawing Markings: The Drawings are marked "For MoA Review Only". When written notification that the review is complete and that there are no further comments is received from MoA On-Site Department, the note will be removed and "Issued for Construction" drawings will be issued. Mailing: P.O. Box 100217, Anchorage, AK 99510-0217 Physical: 332 East Manor Ave, Anchorage, AK 99501 Telephone: (907) 272-8218 FAX: (907) 272-8211 Page 3 of 3 The proposed installation will not affect the future development of the surrounding or existing lots. If you have any questions or concerns, please contact me at 272-8218. Sincerely, Steven R. Pannone, P.E. Owner/Civil Engineer Mailing: P.O. Box 100217, Anchorage, AK 99510-0217 Physical: 332 East Manor Ave, Anchorage, AK 99501 Telephone: (907) 272-8218 FAX: (907) 272-821~. 21 11 AREA MAP SCALE 1" = 100' t..=..,,i 'MUNICIPALITY OF ANCHORAt..j DEpARTMENT'OF HEALTH AND ENVIRONMENTAL PROTECTION SOILS LOG -- PERCOLATION TEST PERCOLATION' TEST SLOPE .~ I'1" t~ PLAN WAS GROUND WATER 1 1 ?J~ 5 '~; ¢- ENCOUNTERED? ~..~-f: (D; t,~f~,,~) ~.s'~'~;/~~''~:~' DEPTH? ~3- ~. 4~ ~, - ~+ ~ ~ Depth to Net 14 Reading ~ater Drop 20 ' ~ Iml r,u ~ o'.tin chi ~- .~ ! PERCOLATION RATE .- TEST RUN "E"I~¥EEN ~"' FT AND 7 ,. FT P~r~ )~' J~ ~ J PERFORMEO BY:_. · CERTIFIED Ry; DATE: ,. Well Log ~oo~t~o~ ....... ~.?.~.....~....,....~......c.......?....~.~.:.~.... :~ ................... Size of casing .......... .~ .............................................................. .a.~.~-~ .................... Dist~ee to water while pumping ........... :_...~,.~ ........................... at rate of ................. : ...... ..'f}..~...O. ............ gallons per, hour. Formation from to 0 /1 DELTA DRILLING COMPANY SRA SOX $94 B ANCHORAGE. ALASKA 99507 DEPARTMENT OF HEALTH & HUMAN SERVICES '~,,~ ~-"R~/.,~,~ ,~. ~ SOILS LOG -- ~/ERCOLATION TEST I'i ~'~'"~" ......... '::'~-~ ~- / ~ / w sh~ ti n SLOPE SITE PLAN 5- 6- 7'-- 57 8- 9- 10- WAS GROUND WATER ENCOUNTERED? 11 -- IF YES. AT WHAT 14- 15- 16- 17- 18- 19- 20- PERCOLATION RATE , ~' I (mmuleshnch) PERCHOLEC~AMETER BETWEEN '~-- FTAND .~ FT COMMENTS · - CERTifY THAT THIS TEST WAS PERFORMED ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DAT~ MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION 925 L* Street, AnchoraBe. Alaska 99501 2644720 SOl LS LOG - PERCOLATION TEST SO~LS LOG PERCOLATION TEST 11 5' 6- 7 13- 14 15 16- 17 18 lg 2O COMMENTS'~ PERCOLATION RATE ~ J~/I t~r ,/~ (minutes/inch) TEST"U..ET~EE. . ~ FT A"D ~- , PT 12-008 (6,r79) CERTIFIED BY: DATE: MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVIRONIV]ENTAL PROTECTION 825 b Street, A~chora§e, Alaska 9950~ 264-4720 SOILS LOG - PERCOLATION TEST SOl LS LOG [~ PERCOLATION TEST PERFORMED FOR: LEGAL DESCRIPTION; 1 2 3 4 5- 6 · 7 8 9 10 13- 14- 15 16 17, 18- 20- SLOPE SITE PLAN WAS GROUND WATER ENCOUNTERED? I F YES, AT WHAT PERCOLATION RATE TEST RUN BETWEEN COMMENTS .,~J~-~,~ /' ~"¢~r 72-008 ( ~ ~ / ~ ~ J ~ EXlqTIN0 DRAIN FIELD (E) TO BE ~/ELL ~E, , ~ ~ / ~' ~~,,~ ABANDuNED AT TIME OF CONSTRUCTION ~ I ~ ~4~Y DE&N FELD (P) ',~ A~A~DO[ ED ~CONCR TE! % I T H ATTACHED ~ Xl I ~ ~Fu JNDATiON CLEAN OUT ~ / 'x , 'q ,,, : ~ / ~ EXISTING 4 BEDROOM /' I ,--i ,,, HOUSE (E) ~ % ' I~ LOT20 " / ¢ LOT,*, i ,¢ : i ~ SUNSTONE OI'R ~ WELL (E) / ~TE: ~EXCAVATEWlTH CAUTION, UTILI~IN AREA OF D'AINFIELO FOR CONSTRUCTION P.O. BOX 100217 ANOHORAOE, AK 99510~,~ .' ....,~ .:~,~'. Scde TALIJS WEST ~1 BLK 5 LT 19 x ~_~E~h.~oh¥6~.~ ~s-202-39 KENNETH ~ YOKO CHALK ~¢i~-. CE 8149 .'~ ~ERMIT NO 4511%UN%TONE ~ ........ PLAN ANCHORAGE, AK 99516 SPECIAL PROVISIONS TO SPECIFICATIONS 1 ALL CONSTRUCTION SHALL BE INSTALLED AS SPECIFIED IN THE blOST CURRENT EDITION OF THE MUNICIPALITY OF ANCHORAGE STANDARD SPECIFICATIONS (MASS) FOR COMPONENT PARTS AND MATERIALS USED IN CONSTRUCTION OF ON SITE WASTEWATER DISPOSAL SYSTEMS AND ATTACHED PES SPECIAL PROVISIONS. .3. SCOPE OF WORK: INSTALL NEW 1500 GAL S,T.E,P TANK AND SOIL ABSORPTION SYSTEM. 4. GROUNDWATER WAS ENCOUNTERED AT A DEPTH OF 6.5 FEET BELOW EXISTING GRADE AS EVIDENCED BY THE SOIL TEST HOLE. IF AN APPARENT WATER TABLE IS OBSERVED IN ANY OF THE EXCAVATIONS LESS THAN 6.5 FEET BELOW EXISTING GRADE NOTIFY THE ENGINEER IblbIEDIATELY. PRIMARY SYSTEM ~ z ~ ~ ~ , , / FLTERFABRC  1500 g S,T.E,P. ~ NO DESIGN PARAMETERS PRIMARY/ RESERME SEPTIC SYSTEM A~B~VhATIONS NO. BEDROOM: & (600 gpd) CU COPPER TANK SIZE: 1500g STEP LEGEND DIP DUCTILE IRON PIPE PERC RATE = 1 MPI TH TEST HOLE SOIL RATING: 6 GPD/SF (for eng fill) -W- WATER LINE/ FC FOUNDATION CLEAN OUT AREA RQD: I OOSF WELL RADIUS SOIL R~TINO: 5 GPD/SF (IN-SITU SOIL 6-15MPI) Tff TANK CLEAN OUT NO. AREA RQD: 120 SF -- SS -- NEW SEPTIC C~ CLEAN OUT NO SYS. TYPE: WIDE TRENCH 05' ED. Mff MONITOR TUBE NO. MIN LENGTH: 20LF R I RIGID INSULATION DCO DOUBLE CLEAN OUT USE: DV DIMERTER VALVE 20 -' ' -' LF X 3 Y¢IDE. 0 o ED. + 4.6' TD FS FLOW SPLITTER ON TOP OF BFG BELOW FINISH GRADE 2' SAND LAYER THEN GO ORIGINAL GRADE 21 LF X 6' WIDE 9' MOA TYPE Il. FO FINISH GRADE TOTAL AREA: 1OO SF (ENO FILL) ~ 126 SF (IN-SITU SOIL). TS~V TOPSOIL ~ VEGETATE OT S: ENG LLC ~6 oF AL~i 9/29/2014 JFOR CONSTRUCTION P.O. BOX 100217 ANCHORAGE, AK 99510~__~ %,, ........~ .,~,~.~ ~ PHONE (907)272-8218 FAX <907)272-8211 ~' ~..'~,,, TALUS WEST ~1 BLK 5 LT lg . ~_:R_.pSk.¢6F,&.~mm KENNETH A YOKO CHALK~% ~~.. CE 8149 .~ PERMIT NO 4311 SUNSTONE DESIGN DETAILS ANCHORAGE, AK gg516'I~ ~OFESS,,O~~ Sheet ADVANTEX DESIGN PRIMARY SYSTEM ADVANTEX 24'* PASSIVE 4* JIM CApCX20 POD~ INSULATED AUXILIARY ~ ~ RISER PUMP X VE N~T% / L El ~ ,o ~ 64. SLIDE SECTION ~ ~1 OVER THIS CONNECTION TO PROVOE SHEER PROTECTION 14' EXTEND TO BRIDGE EXCAVATION WEIGHT CALCULATIONS TALUS WEST Buoyon~ Eorce = Weight of Woter Disploced  .iANOUT ((Pix(5 3372/4)xlO)x62 4 PCF = 13,9¢0 # Up ~-8' ]~4 COUNTER WEIGHT O' NATIVE MATERIAL Assume water @ 6 5' oil soil unsaturated '~ , x ~;~ ~ / ' x ¥~ Assume tank has no weigh( t: :::::-~ ~¢ -:: SEWER ROCK E(4'x5 33'x10')-~(4'x P1(2.3 z)/4)+(3 x 2.5 x Tole[Weigh(on Tank = 18432 6 ~ OK~ SECTION 9/29/2014 PHONE (907) 272-8218 FAX (907) 272-8211 Scde PID. NO TALUS WEST ¢1 BLK 5 LT 19 KENNETH A YOKO CHALK ~'. 4311 SUNSTONE *l%'. '~ 0SP141161 SiTE SECTION ANCHORAGE, AK e95~6 ,!~<?~b~syE~ Sh~t SOILS LOG - PERCOLATION TEST TEST HOLE 1 SLOPE ] ~¢ ~ SITE PLAN MUGM GRAVELY SILT ~4 -~'-~%N~ ] ~ I ' I ~ 5/20/2014 ~ TH ~ ~NN,EL (E) SUNS*ONE~ LWELL (E) ~ . WAS GROUND WATER SLOPE 14 ~ ENCOUNTERED? Y 15 ~ GRAVELY SW/GM SAND WITH IF YES, AT WHAT TH 16 ~ SOME SILT DEPTH? 12.0'(Seepage) X 17 DEPTH TO WATER AFTER BOH MONITORING? -6.5'- 18 I DATE: 5/20/2014 WATER I 19 READING DATE CLOCK NET TiME LEVEL NET DROP TIME READING 20 I 5/13/14 11:43 --- 2.60 --- 2 12:13 30 MIN 2.65 0.05 DATE PERFORMED: 5/16/2014 3 12:07 --- 2.25 --. 4 12:17 30 MIN 2.27 0.02 PEROLATIO~ ~ATfi ~500 {min/inch) P~RC HO~E DIA~ETE~ g inches TEST ~U~ B[TW~fi~ 3 COMMENTS: Test hole excavated by A+ HOME SERVICES. PERFORMED BY: Steven R. P~none, P.E. I CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORD~CE WITH ALL STATE AND MUNICIPAL GUIDLINES IN EFFECT ON THE DATE OF THIS TEST. FOR CONSTRUCTION p.o. BOX 100217 ANCHORAGE, AK 99510 PHONE (907) 272-8218 FAX (~07) 272-8211 ~.,, ~..~ f~ Sco~e WATER I READING DATE CLOCK NET TIME LEVEL NET DROP TIME READING ~ 5/13114 11;43 ... 2.60 --- 2 12:13 30 MIN 2.65 0.05 3 12:07 -. 2.25 --. 4 12:17 30 MIN 2.27 0.02 6 TALUS WEST #1 8LK b LT 19 KENNETH & YOKO CHALK 4511SUNSTONE SOILS LOG ANCHORAGE, AK 99516 ~"~..~.~.MUNICIPALITY OF ANCHORAGE '-,:[, ~,,' ~J DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION ENVIRONMENTAL ENGINEERING DIVISION 825 L Street- Anchorage, Alaska 99501 Tdephone 264-4720 ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT ¢ PHONE NEW NAME MAI LING ADDRESS LEGAL DESCRIPTION NO. OEBEDROO. / DISTANCE TO: ]Well /0 (~ '~'- IAh'°rpt'°n Dw.,,,ng PER.,TNO . O mufacturer ~,~, ~[~f~ No. of compartments capacity in gallons IF HOMEMADE: 11~j~,~gth Width Liquid depth DISTANCE TO: Manufacturer DISTANCE TO: ~'~O '(~ PERMIT NO. Liquid capacity in gallons No. of lines of each line Total length of lines Top of tile to finish grade .~ Material beneath tile Length Width Depth Material Nearest lot line ~ ~ / Trench width ..1~ Distance betwee Ii es Total effective ab,~grption area PERMIT NO. DISTANCE TO: Well DISTANCE TO: Crib depth foundation let Total effective absorption area Nearest lot line Distance to lot line Septic tank /0~) PERMIT NO. ~C C~ ~' I Absorption area(~) [ 0~) ! OTHER PiPE MAT ER IA ,L.~. , $~ff- TEST RATING , N STA L~.~) REMARKS ~ ~ /J APPR ED , DATE 72-013 (Re¢fi/78J LEGAL ,.- .EF FIE.'] rlENT ~.. EHLTH RND EN%,'IR-NHENrFR/ ~~ ....... L "¢rREET.. FINCHuRR,SE, RK. s,S,5¢.,L~¢ PERMZ'T' NO. L 0 C R T Z 0 N 1.4 Z L E:~~ . -- o -- - LEGRL L$9 8.5 TRLIJ5 WEST ~(.IE: LOT %ZZE $,-,E~id~J '~ ....... , o ..... -,b.!OHRE FEE T T'¢F'E OF SOZL HB_,ORE,] ZuN c ..... , q, , l" '"~' I lh.',ZHJH NUMBER OF DEE:,RZOM'E; = ~ ~ '-~aZL R ~ .-~,~] FT, BR..= L~ ,~.-, THE REQUIRED SIZE OF THE SOI TIO~ S'~'~TEM t'q, I'"-'- ............. rl uh. hi/ ta THE r)T,z~;]r.~- =,~m,- .f' -'"--'. ','.-,,-,'~,-ZCLd~. ........ u'¢ ........ ~-W~EN I HE 5URFRCE OF' THE aRULIND RN[:, THE E,U~TUH OF THE E:qCR',,,'RTIOb/ ':lIN FEET). THERE IS NO -,ET WIDTH FOR TRENCHES. THE GRR',/EL DEPTH I~; THE MINIMUM ~EPTFI OF G '~,'~ R .... BETNEEN THE .6~LiTF~:L: F'tPE FINE:, ]"HE E:OT'FOM OF THE EXCRVRTION "IN FEET). .................... F'-- ....... R PH-.KHGE PLFINT MR'¢ BE INSTRLLED RT THE F'ERMiT~c~..~ F'OLLOklINQ CON[:,ITIONS: '~ ~ OPTION SI IB.TEDT EITHEr' R CLRqq *' -'~, · .... ,.- , RGREEF'ENT Iq''NFIT ~"~ .... :',.....,~]a~%b:Hbr.4~ IS, REI;¢IIF'ED" IF ¢~ r4~'~;~-~-.. _: .......... ;',:Fl I:11~ '~,JT g't-~ll ~a,-,~G ..-- :-- ' " ...... K_. ~'~ -"-'~'-'~'--~ ~L PRO5;ECUTION. E, HUF..FILLI'.,U OF RNa' ~z,.,,z ., -,r-,TEH WITHOUT FINRL IN-FECTION RND I~PF'ROVRL E:'EPRRTHENT klILL BE '= ' * P 9- ~ '- -,UBJEL. T TO RL ~EuUTI UN. F1]:NZHuH DIB'rRNCE BETWEEN R WELL RN[:, RN'¢ ON-SITE SEWRGE DIZ;F'OBF:~t ...... r__,TE~,] I~; ZEnD FEET FOR R PRIVRTE WELL OR 2RR FEET FOR R PUE:LIC ~'.IELL.. WELL L~Ua RRE REQUIRED RN[:, HLI'ST BE RETURNE[ TO THE DEF'FIRTMENT NITHIN ]~8 Cd-Irc, OF THE NELL COMPLETION.' ' _ ,,- OTHER - -, .... RE~UIREHEh b MFI'¢ FIPF'L~.'. ~- : -,FEL. IFIL. MFI~Nq FIN[:, 'F .,-" · -- - UJNz,]RLu[ IIJN D:[RGRRHs RRE RVR[LRBLE TO INSURE F'RZ~F'ER ZNSTRLL. RTZON. .. [- ~" ~ ~ % '~ ~ :=< P ~ ~: ~ '~; E> ~ ,2: ~ ~-"1 ~ ~ F~: ~: ~... . ,,_~ -~:. %.2: .... t CERTIF'N' 'FHRT Z: I FIM FRHILIRR WITH I"HE RE~!UIREMENT$ Fn~, ON-$ITE 5E[,.tERq 'RN[:, WELL:5; FORTH B'¢ THE HUNICIPRLIT,¢ OF RNE:4ORRGE. 2: I 14ILL INSTRLL THE ,=~,,-'-, - -,r=,TEH IN RCCORDRNCE ~4ITH THE ~1ODER $' I LINDERSTRND THRI' THE oN-$ITE %EWER '-'"- - -' -' "- m~:,TEM fiR? RE:~I 'FRE EF,fLRRGEHENT IF THE ~ESIE:,ENC:E ].:, REMODELED ]'0 ~ ........... IN_.LUDE I"~ORE THRh¢~ 5 E:EDROOM$. ;I GNED: .................... RPF'[~ I L-:FINT ~4ILL IFIM S I EF'IENS ......... '~ '~ .... ~ ............ [:'R l" _ ......... M-W DR LLING IHC. DRILLING LOG S Well Owner- Location (address of: Township, Range, Section, if known; or distance main road Lot 19 Block 5 Talus West _Use of Well Dom, Size of casing__ 6'::...Depth of Hole_.__'53_ .- feet_ .... Cased... to- 52.3 fe~t Static water level 30 ft. (&h(/9~) (below) land surface. Finish of well (check one) Screen ( ); Perforated ( )- Describe screen or perforation-- N/A Well pumping test at 20 .gallons per (hiibr) -of drawdown from static level. 6/21/78 Date of completion (minute) for ] hours with- 1 007, open end ( x~c ); Depth in feet from ground surface WELl. LOG Give details of formations penetrated, size of materiai;'color and hardness _ ~') ._TO 2 · _TO 5 TO. TO~7 47 4! TO_ 47 TO. 53 TO _TO. _TO . .TO Cas'inz .s tic..kt;o _Or ~antc.s_ i~ou!c!er _ ._ Silty ,-,-_%¢~y .. ~!d~r silty sand: gravelly -- -- S~ tv water ~raval ~.~,-~,,~ gravel 3--CONTRACTOR ,.,. 4649 BUSINESS PARK gI..VD, P.O. BOX 4-1276 ANCHORAGE, ALASKA ~,o09 TELEPHONE (g37) 2794014 B=inMn§ Wa~er Analysis Report for Total Co~form gacte6,a TO BE CO~¢,PLEi'ED BY WATER SUPPLIER I.D. NO. Mo. Day Year Code SAMPLE TYPE: [] Routine [] Check Sample (for routine sample with lab'ref, no. [] Speclal Purpose [] Treated Water [] Untreated Water SAMPLE NO, 1 2 3 4 5 LOCATION I L Time Collected Collected By TO BE COMPI.b~'ED BY I,~,~BOP~ ,TORY LABORATORY: CHEH & GEO LABS OF AK. , INC. NAME 4649 BUSINESS PARK BLVD. ADDRESS ~AGF .._ Al ASKA CITY Time Received ' Analytical Method: ~ Fermentatfon Tube ~Membrane Filter Lab Ref. No. Result* Analyst L J LII READ INSTRUCTIONS BEFORE COLLECTING SAMPLE Form No. 18-310(3-78) 06-1220 (b) Rev. 1978 BACTERIOLOGICAL WATER ANALYSIS RECORD 113=]-%--78 Time Received] *45 L,b.~o. 8837-38 Broth 48 hoursJ ~.Oml Tubes Positive/Total ~.Oml portlonl REQUEST FOR APPROVAL OF INDIVIDUAL WATER AND SEWER FACILITIES MUN C PALITY OF ANCHORAGE DEPT, OF DEPARTMENT OF HEALTH & ENVl RONMENTAL PROTEC'Fc~CJ~,ONMEN'~AL pROTECTIO 825 L Street - Anchorage, Alaska 99501 0OT~) 1978 ENVIRONMENTAL ENGINEERING DIVISION Te,epho.e 2..-.720 RECEIVED DIRECTIONS; Complete air parts on page 1. Incomplete requests will not be processed. Please allow ten (10) days for processing. 1, PROPERTY OWNER ~-/~ PHONE MAILING ADDRESS PROPERTY RESIDENT (If-~i~fe~en't from above) MAI ~zl N G ADDRESS -- 3. LENDING INSTITUTION MAILING ADDRESS PHONE ~PHONE PHONE 4. REALTOR/AGENT TYPE OF RESIDENCE NUMBER OF BEDROOMS '~' SINGLE FAMILY [] One ~ Four [] Other [] Two [] Five [] MULTIPLE FAMILY [] Three [] Six 7. WATER SUPPLY ~ INDIVIDUAL* * ATTACH WELL LOG. A well log is required for all wells drilled El COMMUNITY since June 1975, For wells drilled prior to that date, give well [] PUBLIC UTI LITY depth (attach log if available.) 8, SEWAGE DISPOSAL SYSTEM ~ INDIVIDUAL/ON-SITE** ~*lf individual/on-site, give installation date ~'/~' , [] PUBLIC UTI LITY If system is over two (2) years old an adequa~y--test is required by this Department. NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH REQUEST BEFORE PROCESSING CAN BE INITIATED. 72-010(3/78) THIS SIDE FOR OFFICIAL USE ONLY )ATE RECEIVED INSPECTION APPOINTMENTS TIME TIME TIME --DATE ]ATE )ATE INSPECTOR INSPECTOR ,NSPECTOR DiRECTiONS: 1, TYPE OF RESIDENCE NUMBER OF BEDROOMS [~ SINGLE FAMILY [] ONE [] THREE [] FIVE E~] OTHER L~ MUI.TIPLE FAMILY [] TWO [] FOUR [] SIX -- PERMIT NUMBER 2. WATER SUPPLY [] . INDIVIDUAL DEPTR OF WELL [] COMMUNITY DATE DRILLED [] PUBLIC UTi LITY Connection Verified__ LOG RECEIVED PERMIT NUMBER 3. SEWAGE DISPOSAL SYSTEM []INDIVIDUAL/ON -SITE DATE INSTALLED ~ ~,~.~ (~ ~PUBLIC UTI LITY Connection Verified _ INSTALLER []Septic Tank or [~] Holding Tank Size:_ If Tank is homemade SOIL8 RATING give dimensions: ~OTAL AESORPTION AREA MATERIAL 4. DISTANCES Septic/Holding Tank Abso~rptlon Area Sewer Line I Nearest Lot Line WELl-TO: - Absorptio~ Area to nearest Lot Line 5, COMMENTS VED FOR z~ BEDROOMS [] CONDITIONAL APPROVAL (~etter must accompany certificate) ~]~ D~SAPPROVED LEGAL DESCRIPTIO~ 72-010 (Rev. 3/78)