Loading...
HomeMy WebLinkAboutDUKE & DUCHESS BLK 2 LT 3Duke & Duchess Block 2 Lot 3 #051-221-56 Municipality of Anchorage On-Site Water and Wastewater Program • (907) 343-7904 Page of ON-SITE WASTEWATER INSPECTION REPORT Permit Number: OSP141417 PID Number: 051-221-56 Dwelling: N Single Family (SF) ❑ Duplex (D) ❑ Multiple (SF and/or D) Project: ❑E New ❑ Upgrade Name: J. A. Sartin ABSORPTION FIELD ❑ Deep Trench N Shallow Trench ❑ Bed ❑ Mound Address 1231 W. Northern Lights #842 Anch., AK 99503 ❑ Other Phone Number of Bedrooms Soil Rating Total depth from original grade 3 1.2 GPD/SF 5.5 Ft, LEGAL DESCRIPTION Depth to pipe invert from original grade 3.5 Ft. Gravel depth beneath pipe 2 Ft. Subdivision Block Lot Duke & Duchess 2 3 Fill added above original grade 0-.5 Ft. Gravel length 55 Ft. Township Range Section Gravel width 5 Ft. Beds: Number of Lines Distance between lines Ft. SEPARATION DISTANCES To Septic AbsorptionHolding Lift Station Sewer Total absorption area Number of trenches Dist. between trenches From Tank Field Tank Line 393 Ftp 1 Ft. Well >100, >100, >100, >75' >25' TANK ❑O Septic ❑ S.T.E.P. ❑ Holding ❑ Other Manufacturer Anchorage Tank Capacity 1,000 Gal. Surface Water >100' >100' >100' NA Material Steel Number of compartments Two Lot Line >5' >10' >5' NA NA Foundation >5' >10' >5' NA LIFT STATION Manufacturer Capacity Gal. Curtain Drain None Noted Pump on level at Pump off level at High water alarm at Remarks in. in. in. Pump make and model Electrical Inspections performed by PIPE MATERIAL House to tank D3034 Tankto drainfield D3034 Installer Northern Excavation Draintield D3034 caMT Inspector A. Harala BENCHMARK (Assumed elevation) 100.0 ft Inspectiones: �2/10/15 2/10/15 Location and description 2n° 6/8/15 4'h Front Deck. COMMUNITY DEVELOPMENT DEPARTMENT APPROVAL EWWW �E.F.;q(�S��1 Conditional Approval: Date ���PO r� so 4gT ' ... ... .... ., .... i................................ %*.MICHAEL E. ANDERSON I�"yl,•� CE-4381 •'fir AW Approved,,,& Date w ".2a-/ Inspection Report_9-1a2.d6c(/ Municipality of Anchorage DEVEOPMENTSERVICES DEPARTMENT 4700 Elmore Road Anchorage;`AK.-99519-6655 - 343-7904 Permit Number: OSP141417 DUKE Page 2 of 3 PID NO.: 051-221-56 8c DU I HESS SUBDIVISION LOT, 3, BLOCK 2 1 47,260 S.F. BEND NG BIRO =--_ -_ H DRI s�Oo 5 SNOW STORAG _ E EASEMENT W. Q: 19 O A p O 52 12.9' 29.1' Mt 39.1' 57_4' � C5 44.2' 63.5' (V O O O O LEGEND Z FCO — Foundation Clean Out TH - Test Hole S1 - Septic Vent MT - Monitor Tube CO - Clean Out 49th AEL E. ANDERSON No. CE -4361 6-23-15 [ i r 1 i i T. IpEE BEDROOM � Hp4iE i pgernA>,e.S�r I I ' I 1 S89°58'35"E 230.35 Existin Well LOT 2, BLOCK 2 PLAN AS QUILT SCALE 1" = 50' Municipality. of -Anchor DEVEOPMENT SERVICES—IDI 4700 Elmore Road Anchorage, AK 99 On -Site Wastewater Disposal System or Permit Number: OSP141417 FME+ T 655 - 343-7904 99.3 N UU �Erisi'n� fi she .cu�l� rcand L L 11500 Ga for .. 7 SepticTon!t: - jI x.95 _/ ! 95.1 07 M H Page 3 of 3 PID No. 051-221-56 CJ PROFILE AS -LB ..1ILi' No scala �...-------- — Municipality of Anchorage ONSITE WATER & WASTEWATER PROGRAM CHANGE ORDER PERMIT # OSP141417 PID No: 51-221-56 SUED Duke & Duchess TRACT. CONTACT PERSON Michael E. Anderson, P.E. PHONE 522-7773 FAX 677-7766 BLOCK 2 LOT 3 PLEASE GIVE A DESCRIPTION OF THE CHANGE: The clean gravel soils were found to extend only to a depth of 9' below grade. The effective depth of the trench was reduced to 2' from W to provide more area for percolation of effluent. The length was extended to a total Of 55'. A three bedroom home with an application rate of 1.2 GPD/SF and a .7 Reduction Factor for a 2' Effective Depth requires a length of 52.5' CUSTOMER On -Site Reviewer: APPROVED (date) Comments Review Issued Time (date) (hours) TOTAL HOURS HOURLY RATE 4;140 TOTAL TO BE PAID DATE PAID RECEIPT # LOT 3, BLOCK 2, DUKE AND DUCHESS SUBDIVISION DESIGN FACTORS: SYSTEMREQUIREMENTS: Three Bedroom Home 5'' Wide Trench System Perc. Rate: 1-5 Min./Inch 1,000 Gallon Septic Tank Application Rate: 1.2 GPD/SF 2' Drainfield Rock 3 Bedrooms * 150 GPD/Bedroom = 450 SF Absor tion Area 450 SF/1.2 GPD/SF/5 SF (Width) *.7 (Red. Factor= 52.5 LF Trench Length THEREFORE: Construct a 53' Long x 5' Wide x 2' Effective Depth Absorption Trench. Flow Line Elevation in Trench to be 3' Below Original Ground Surface. Total Depth to be 5' Below Existing Ground. Provide 3' Cover Over Absorption Trench and 4' Cover Over Septic Tank. 5' f� TYPICAL 5' WIDE TRENCH SECTIONOF •.., (NO SCALE)���p(E..........:�.q NOTE: Grade Area Over Trench to Drain Away. :;' 49m Minimum 6' Separation From Bedrock. :....` ........... Minimum 4' Separation From Groundwater. i • .............................`4l. Minimum 100' Separation From Private Wells in the Area. ��, micHnELe.,woeRsoN Minimum 100' Separation From Surface Water or Streams. No. CEA381 MUNICIPALITY OF ANCHORAGE DEVELOPMENT SERVICES DEPARTMENT 4700 BRAGAW STREET ANCHORAGE, AK 99519-6650 SOILS LOG - PERCOLATION TEST LEGAL DESCRIPTION: DUKES AND DUTCHESS BLOCK 2 LOT 3 PERFORMED FOR: SCOTT PEPPERS DATE: 2/10/15 PROJECT No.: PARCEL ID#: TECHNICIAN: AH DEPTH (feet) 1 — 2 — 3 — 4 — 5- 6- 7- 8- 9 10- 11- 12- 13- 15 0- 11- 12- 13- 15 16 17 18 19 TEST HOLE A OB/OG SILTY SAND WITH GRAVEL SM/GM BOH @ 16' WAS GROUND WATER ENCOUNTERED? No SITE PLAN SEE SITE PLAN i Y a IF YES @ WHAT DEPTH? S GROSS TIMEJ (MINUTES) DEPTH OF WATER AFTER MONITORING: LO NET DROP (INCHES) TEST HOLE PRESOAKED PRIOR TO TESTING: 7 DATE OF MONITORING: P 10 0.75"/6.75" 6.00" DATE READING GROSS TIMEJ (MINUTES) NET TIME (MINUTES) DWgTER (INCHES) NET DROP (INCHES) TEST HOLE PRESOAKED PRIOR TO TESTING: 2/10 1 10:12/10:22 10 0.75"/6.75" 6.00" 2 10:23/10:33 10 1.00"P7.00" 6.00" 3 10:34/10:44 10 0s0v6.50" 6.00" 4 10:45/10:55 10 1.00"/7.00" 6,00" 5 10:56/11:06 10 i m,r.00" 6.00" 6 11:07/11:17 10 0.75"/6.75" 6.00" PERCOLATION RATE: 1.7 (MIN/INCH) PERC. HOLE DIA.. 6n (INCHES) TEST RUN BETWEEN: 4 FT. and 5 FT. COMMENTS: TEST HOLE PRE SOAKED PRIOR TO TEST. PERCOLATION TEST TEST PERFORMED BY ANDERSON ENGINEERING. I, MICHAEL E. ANDERSON CERTIFY THAT THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPLE GUIDELINES IN EFFECT ON THIS DATE: 6/23/15 Certified Drilling Lae DOC CO dba 4BALL & COLE - ULLIVAN WATER WELLS P.O. Box 670269, Chuglak, AK 89567 688-2759 OWNER OF LAND: Peppers Construction ADDRESS: 10224 Eagle View Dr, Eagle River, AK 99577 LEGAL DESCRIPTION Duke & Duchess Blk 2 Lot 3 DATE. 10-27-14 PERMIT NUMBER: OSP141417 DATE OF ISSUE: 10.7-14 TAX IDENTIFICATION NUMBER 05122156000 Is well located at approved permit location: Eyes ONo Method of Drilling ®air rotary ❑cable tool Depth of Well: 500 feet Casing Type: steel Wall thickness .250 inches Diameter. 6 inches, depth 44 feet liner type None Static Water Level: 75 feet Recovery Rate 10 Lj gpm gph Method of Testing air Well Intake Opening Type: open end pen hole ❑ Screened Start feet Stopped ❑ Perforations Start feet Stopped Grout Type: Bentonite volume: 120 lbs Depth: from 2 Feet, to 42 feet Well Disinfected Upon Completion: M;;;Qno Method of Disinfection: Chlorine SO PPM Comments: Depth Fran To 0 2 Casing Stickup 2 4 Overburden 4 23 Silty sand & gravel 23 34 Bedrock brown 34 268 Bedrock green hard 268 271 Bedrock green w/ fractures 271 320 Bedrock green W/ quartz 320 462 Bedrock green hard 462 474 Bedrock brown 474 500 Bedrock green hard Drillers Name: Cole Sullivan A7TENTION. It is the responsibility of the property owner to submit a copy of the well log to the proper authority. Municipality of Anchorage: Department of Neaith & Human Services and/or Department of Environmental Conservation. MatSu Borough: Department of Environmental Conservation. TO/T0 39Vd Sb3dd3d 0896V69L06 90:VT 9TOZ/6T/90 ARCTIC PUMP & WELL INC. Jim Sullivan PO Box 770197 wam Eagle River, AK 99577 uirt a sm�c - (907) 688-2510 (907) 243-2282 Pump Installation Log `Well Drilling Permit Number: osp141417 Parcel Identification Number: 05122156000 Date Of Issue: 10/7/2014 Wednesday, December 03, 2014 Legal Description Duke and Duchess B2 L3 Property Owner Name Address: Peppers Construction Lot: 3 10224 West Frontage Block: 2 Eagle River AK 99577 Pump Installaion Date: 12/1/2014 Pump Intake Depth Below Top of Well Casing: 476 Feet Pump Manufacturer's Name Franklin Pump Model: 7JR1 S4 -2W230 Pump Size: 1 HP Pitless Adapter Burial Depth: 14 Feet Pitless Adapter Manufacturer's Name S-50 Pitless Adapter Installer: u/k Well Disinfected Upon Completion? Yes Method of Disinfection: Chlorine Comments: Pump Installer Name: Arctic Pump & Well, Inc. Wednesday, December 03, 2014 On -Site Water & Wastewater System Permit MUNICIPALITY OF ANCHORAGE Development Services Department On -Site Water & Wastewater Program 4700 Elmore Road, PO Box 196650 Anchorage, AK 99519-6650 Telephone: (907) 343-7904 Permit Number: OSP141417 Tax Code Number: 05122156000 Work Type: WellSeptic Initial Permit Effective Dates: October 07, 2014 to October 07, 2015 Design Engineer: ANDERSON ENGINEERING Subdivision: DUKE & DUCHESS Site Legal Address: DUKE & DUCHESS BLK 2 LT 3 G:1057 Owner/Address: SARTIN J A 1231 W NORTHERN LIGHTS BLVD #842 ANCHORAGE AK 995032337 Site Mailing Address: Lot Size in Sq Ft: 47260 Total Bedrooms: 3 This permit is for the construction of: Y Disposal Field Y Septic Tank N Holding Tank N Privy Y Private Well N Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80). 3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either: A. Open and Close on the same day. B. Covered, sealed, and heated to prevent freezing. Received Issued By: Date: to I�f Date: �o l Municipality of Anchorage P.O. Box 196650 • 4700 Elmore Road Development Services Division On -Site Water and Wastewater Proaram went llepartment **** VARIANCE/WAIVER REVIEW **** Waiver#: OSP141450 COSA#: Permit#:OSP141417 PID#: 051-221-56 Legal Description: Duke & Duchess Block 2 Lot 3 Engineer: Anderson Engineering Applicant: J. A Sartin Your request for a waiver of the required 50 feet horizontal separation from the absorption field to the excessive slope has been approved. The approved separation distance is 16.0 feet for the primary field and 31.0 feet for the alternate field. This waiver approval applies to the proposed absorption field only. Any future upgrade to the on-site wastewater disposal system will require all separation distances be met or another approval from this department. ❑ The affected adjacent property owner(s) have been given a 7 day notice regarding this waiver. ❑ Notarized letter(s) of nonobjection have been received from the owner(s) of the affected adjacent property. ® Adjacent properties are not affected by this waiver. ............................................................................... Waiver is Granted: X Waiver is not Granted: Date: %aq Approved by: /N Name of RevieweK ........................................................... ........... 0...... **** VARIANCEIWAIVER REVIEW **** MUNICIPALITY OF ANCHORAGE Community Development Department Phone: 907-343-7904 Development Services Division _ Fax: 907-343-7997 On -Site Water & Wastewater Program ON-SITE SEWERIWELL PERMIT APPLICATION 051-221-56 Parcel I.D. { Property owner(s) J_ A. Sartin Day phone Mailing address 1231 Northern Lights Blvd., Suite 842 Anchorage, AK 99503 Site address NHN Bending Birch Drive Chugiak, AK 99567 Legal description (Sub'd., Block & Lot) Duke & Duchess, Block 2, Lot 3 Legal description (Township, Range & Section) Lot Size 47,260 Sq. Ft. Number of Bedrooms Three (3) APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (® all that apply) Absorption Field 0 Initial 0 Single Family (SF) ❑ Septic Tank 0 Upgrade ❑ (w/wo ADU) (D) Holding Tank El Renewal❑ ElRenewal Multiple Dwellings Privy ❑ ❑ (SF and/or D) Private Well ❑ Water Storage ❑ THIS APPLICATION INCLUDES A VARIANCE ( WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit/Rush Fees: n/ jr 4 — Waiver Fees: Z I i Date of Payment: A! % / 1 U Date of Payment: Z�Z / Lf Receipt Number:o(o`5 7(c Receipt Number: Off I � % G Permit No. O5P1t I/Y1? Waiver No. 0.S e) `t ( 4 .50 Permit App_9-1-12.doc ANDERSON ENGINEERING P.O. BOX 240773 ANCHORAGE, AK 99524 522-7773 677-7766 FAX September 25, 2014 Municipality of Anchorage Development Services Department On -Site Water and Wastewater Program 4700 South Bragaw Street Anchorage, AK 99519-6650 Subject: Lot 3, Block 2, Duke and Duchess Subdivision Septic System Design and Permit Application Impacts to Adjacent Properties Dear Onsite Services Engineer: The owner of Lot 3, Block 2, Duke and Duchess Subdivision intends to construct a new three-bedroom home on the lot. We are therefore requesting a permit be issued for the construction of a new well and septic system to accommodate the home. The attached Site Plan and backup documentation identify the location and configuration of the proposed well and septic system along with the alternate site. Also identified on the plans are the existing wells and septic systems on surrounding lots. No conflicts exist between the proposed septic system and well or septic systems and wells on adjacent lots. Drainage contours are shown on the site plan showing the grade and direction of flow on the lot. The drainage pattern will not be changed as a result of this project. A test hole was placed on the lot in the area of the absorption trench and alternate site. The logs indicate silty sand with gravel (SM/GM) in the zone specified for the absorption trench. The percolation rate of the soil was determined to be 1.6 minutes per inch. No groundwater was found during the placement of the test hole and none developed during the monitoring period. An application rate of 1.2 gallons per day per square foot was used in the design of the absorption system. We are proposing to place a new 1,000 -gallon septic tank and a 38' long by 5' wide by 4' effective depth absorption trench to treat and dispose of the effluent generated in the house. The elevation of the distribution line in the absorption trench will be 6' below the surface as the trench will be located uphill from the tank and the total depth will be 10'. A minimum of 3' of fill or 2" of insulation and 2' of fill will be placed over the absorption trench and 4' over the septic tank. The ground surface on the lot in the area of the septic system slopes to the northwest. The new trenches will be constructed parallel with the contours of the slope as much as Lot 3, Block 2, Duke and Duchess Subdivision September 25, 2014 Page Two possible in conformance with Municipal requirements. The new septic system will be constructed a minimum of 100' from all wells and any surface water and 10' the proposed and existing water services in the area. If the system is constructed in accordance with our design the following statements apply: 1. The system, if constructed as designed, will have no adverse impact on the wells in the area or those to be constructed in the future. 2. The system, if constructed as designed, will have no adverse impact on existing septic systems in the area or those to be constructed in the future. 3. The system, if constructed as designed, will have no adverse impact on reserve space, either surface or subsurface, on any lots located in the area. 4. The system, if constructed as designed, will have no adverse impact on drainage patterns in the area. The current drainage pattern will be maintained. Sincerely, Michael E. Anderson, P.E. Attachments `. 49th `_ MICHAEL E. ANDERSON No. CE -4381 PROF_SS ANDERSON ENGINEERING P.O. BOX 240773 ANCHORAGE, AK 99524 522-7773 677-7766 FAX October 3, 2014 Municipality of Anchorage Development Services Department On -Site Water and Wastewater Program 4700 South Bragaw Street Anchorage, AK 99519-6650 Subject: Lot 3, Block 2, Duke and Duchess Subdivision Absorption Trench to Slope Waiver Alternate Site Dear Onsite Services Engineer: Lot 3, Block 2, Duke and Duchess Subdivision has limited area for construction of a septic system due to steep slopes and an aerial electrical easement crossing the middle of the lot. The west end of the primary absorption trench is situated slightly more than 16' from a break in grade greater than 25%. The alternate site is 31' from the break. The distribution line in the trenches will be constructed at 6' below grade to provide gravity flow. We are therefore applying for a waiver allowing placement of the absorption trenches at the location shown. Soils in the area are very good for the treatment and absorption of septic effluent. The majority of absorption will be down and migration will be minimal. The imaginary 25% slope from 2.5' above the distribution line does not daylight. We therefore recommend a waiver be issued allowing placement of the absorption trench at 16' and 31' from a slope greater than 25%. Sincerely, Michael E. Anderson, P.E. Attachment !I CONTOUR IN LEGEND FCO — Founc TH — Test H SV — Septic MT — Monitoi CO — Clean DUKE & DUCHESS SUBDIVISION LOT 3, BLOCK 2 47,260 S.F. r 49th ..................... 604... n MICHAEL E. ANDERSON ��up ?, N0. CE -4381 � LOT 2, BLOCK 2 SITE PLAN SCALE 1" = 50' , , , , No Conflicts with Wells or Septic Systems on Adjacent Lots. No Surface Water Within 100' of the Proposed Septic System. Breaks in Grade >25 % Are Shown. LOT 3, BLOCK 2, DUKE AND DUCHESS SUBDIVISION DESIGN FACTORS: SYSTEM REQUIREMENTS Three Bedroom Home 5' Wide Trench System Perc. Rate: 1-5 Min./Inch 1,000 Gallon Septic Tank Application Rate: 1.2 GPD/SF 4' Drainfield Rock 3 Bedrooms * 150 GPD/Bedroom = 450 SF Absor tion Area 450 SF/1.2 GPD/SF/5 SF (Width) *.5 (Red. Factor= 37.5 LF Trench Length THEREFORE: Construct a 38' Long x 5' Wide x 4' Effective Depth Absorption Trench. Flow Line Elevation in Trench to be 6' Below Original Ground Surface. Total Depth to be 10' Below Existing Ground. Provide 3' Cover Over Absorption Trench and 4' Cover Over Septic Tank. 5' TYPICAL 5' WIDE TRENCH SECTION (NO SCALE) NOTE: Grade Area Over Trench to Drain Away. Minimum 6' Separation From Bedrock. �.....: Minimum 4' Separation From Groundwater. s r Minimum 100' Separation From Private Wells in the Area. i""` Minimum 100' Separation From Surface Water or Streams: tic MICHAEL E. ANDERSON No. CE -4391 M MUNICIPALITY OF ANCHORAGE DEVELOPMENT SERVICES DEPARTMENT 4700 BRAGAW STREET ANCHORAGE, AK 99519-6650 SOILS LOG - PERCOLATION TEST LEGAL DESCRIPTION: DUKES AND DUTCHESS BLOCK 2 LOT 3 PERFORMED FOR: SCOTT PEPPERS _ DATE: 8/6/2014 PROJECT No.: PARCEL ID#: TECHNICIAN: JB DEPTH TEST HOLE 1 (feel) 14- 15- 16-- NO OB/OG 111111111111 DEPTH OF WA TER AFTER MO GROSS TIME (MINUTES) 2 DEPTH To (INCHES) ATER N(INCHROP 3 TEST HOLE PRESOAKED PRIOR TO TESTING: 8/6/14 4 3:20/3:30 10 5 6.2 5 " SILTY SAND 2 3:31/3:41 WITH GRAVEL 6 C.25" SM/GM 7 3:42/3:52 10 8 6,25" 9 3:53/4:03 10 10- 011- 6,25" 11- 4:04/4:14 10 141516 BOH @ 16' 17- 18- 19- SITE 71819 WAS GROUND WATER ENCOUNTERED? NO IF YES ¢ WH DAT F DEPTH OF WA TER AFTER MO GROSS TIME (MINUTES) DATE OF MO DEPTH To (INCHES) ATER 49th MICHAEL E. ANDERSON NO. CE -4381 SITE PLAN SEE SITE PEAN A"CDER IT19 J MTORING: NONE O NIT ORING: 9/Z�"�� P E - � DAT F READING GROSS TIME (MINUTES) NET TIME (MINUTES) DEPTH To (INCHES) ATER N(INCHROP TEST HOLE PRESOAKED PRIOR TO TESTING: 8/6/14 1 3:20/3:30 10 5.00"/11.25 6.2 5 " 2 3:31/3:41 10 4.75'/11.00" C.25" 3 3:42/3:52 10 5.00"/11.25" 6,25" 4 3:53/4:03 10 5.00"/11.25' 6,25" 5 4:04/4:14 10 4.75'711 .00" 6.25" 6 4:15/4:25 10 5:00"/] 1.25" 6.25" PERCOLATION RATE: 1.6 (MIN/INCH) PERC. HOLE DIA. 6H (INCHES) TEST RUN BETWEEN: 4 FT. and 5 FT. COMMENTS: TEST HOLE PRE SOAKED PRIOR TO TEST. TEST PERFORMED BY ANDERSON ENGINEERING. 1, MICHAEL E. ANDERSON CERTIFY THAT THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPLE GUIDELINES IN EFFECT ON THIS DATE: 9/26/2014 RUS` Parcel I.D. 051-221-56 ." RC1SHi a U4 . & i� 2Lt15 Municipality of Anchorage a , On -Site Water and Wastewater Program (907) 343-7904 Certificate of On -Site Systems Approval Expiration Date: 1. GENERAL INFORMATION Complete legal description Duke & Duchess, Block 2, Lot 3 Location (site address) 18220 Bending Birch Drive Chugiak, AK 99567 Current Property owner(s) J. A. Sartln Day phone Mailing address Real Estate Agent 1231 W. Northern Lights, Blvd. #842 Anch., AK 99503 2. TYPE OF DWELLING: E] Single Family (w/wo ADU) ❑ Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) 3. NUMBER OF BEDROOMS: Three Day phone, 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well 0 Individual Q Individual Water Storage ❑ Holding Tank ❑ Community Class Well ❑ Community ❑ Public Water System ❑ Public Sewer ❑ WaiverNariance request for: - Distance: Received b � Date: L — 2 3'f(�— COSA to be released to the_,4neer, unless otherwisP`requ4sted by the engineer, COSA Fee $ /I I. (A Waiver Fee $ Date of Payment %a�231f 5 Date of Payment Receipt Number 01 ba G'7 Receipt Number COSA # (3 50 51362 Waiver # 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of Oh -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the oh -site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm Anderson Engineering Address P.O. Box 240773 Anchorage, AK 99524 Engineer's Printed Name Michael E. Anderson, P.E. Phone 522-7773 6. DSD SIGNATURE , „ 4 , ..,t / N, r.........0 _1z System #1 Approved for bedrooms r^ MICHAE FNt)E250N System #2 Approved for Disapproved Conditional approval for bedrooms bedrooms, with the following stipulations: By:�: _ Original Certificate Date: �'oC3'� The ma f Anchor evelopment Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the representation rven in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage Is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: COSA Checklist X Nitrate Advisory Septic System Advisory Arsenic Advisory Well Flow Advisory Other COSA blue sheet ('- I• c If more than 1 septic system is on the lot: COSA Checklist # _of _ Structure served by this system Certificate of On -Site Systems Approval Checklist Legal Description: Duke & Duchess, Block 2, Lot 3 A. WELL DATA Well type Private If A, B, or C provide PWSID # Date completed 10/27/14 Sanitary seal (YIN) Y Total depth 500 ft. Cased to 44 ft FROM WELL LOG Date of test 10/27/14 Static water level IS LS ft. Well production 10 \S g.p.m. WATER SAMPLE RESULTS Parcel ID: 051-221-56 Well Log (YIN) Y Wires properly protected (YIN) Y Casing height (above ground) >18 in. AT INSPECTION Coliform 0 colonies/100 mL Nitrate '127 mg/L Arsenic ND ug/L Date of sample: 5/28/15 Collected by: B. SEPTIC/HOLDING TANK DATA Tank Type/Material Septic/Steel Tank size 11000 gal. Number of Compartments 2 Foundation cleanout (Y/N) Y Depression over tank (Y/N) N Date of pumping New Const. Pumper C. ABSORPTION FIELD DATA In g:p.m. J.S. Date installed 2/10/15 Cleanouts(Y/N) Y High water alarm (YIN) N Date installed 2/10/15 Soil rating (g.p.d.lft2 or ft2/bdrm) 1.2 GPD/SF System type 5' Wide Length 55' ft. Width 5' ft. Gravel below pipe 2' ft. Total depth 6 ft. Eff. absorption area 393 fe Monitoring tube Y Depression over field N Date of adequacy test New Const. Results (Pass/Fail) For—bedrooms i Fluid depth in absorption field before test in. Water added gal. New depth in. Elapsed Time: min. Final fluid depth in. Absorption rate >= g.p.d. Any rejuvenation treatment (past 12 mo.) (YIN & type) N If yes, give date _ D. LIFT STATION No Add On Manhole - Gravity Flow to Absorption Trench. Date installed Size in gallons Manhole/Access (Y/N) "Pump on" level at in. "Pump oft' level at in. High water alarm level at in. Datum Cycles tested Meets alarm & circuit requirements? E. SEPARATION DISTANCES WELL ON LOT TO: Septic tank/lift station on lot > 100' On adjacent lots >1 00' Absorption field on lot >1 00' On adjacent lots >1 00' Public sewer main >75' Public sewer manhole/cleanout >100' Sewer /septic service line >25 Holding tank >75 Animal containment areas >50' Manure/animal excrete storage areas >100' SEPTIC/HOLDING TANK ON LOT TO: Building foundation >5 Property line >5' 5' Absorption field > Water main > 10' Water service line >10' Surface water > 100' Wells on adjacent lots >100' ABSORPTION FIELD ON LOT TO: Property line >10' Building foundation >10' Water main N/A r r r Water Service line > Surface water >100' Driveway, parking/vehicle storage > 10 Curtain drain Norte Noted Wells on adjacent lots >100' F. COMMENTS G. ENGINEER'S CERTIFICATION I certify that 1 have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this date. Engineer's Printed Name Michael E. Anderson, P.E. Date 6/18/2415 COSA brown sheet 10-10-.12.doc lea.es::: a a 6�scai .+ny98 efo0 ct�/•' t 'c '01A01 -o9 'rle eAAe l �. ........... — .. _ _...... r [2] wowvi�+ JL+WAKL) & A5bUUlATEb UMP SUA{VM NG b94-IJUZ9 I HEREBY CERTIFY -THAT I HAVE SURVEYED THE .SCALE �� . , a�'��►°`gya FOLLOWING DESCRIBED PROPERTY: OF a 4'YOGl11r✓�.L3 �'� 2 DATE-, At y� AND THAT NO ENGR(NrCNMENT�S EXIS�f EXCEPT AS s�a��r- y . ' ' •'� INDICATED. 1T IS THE RESPONSIBILITY OF THE rn LV OWNER TO DETERMINE THE EXISTENCE OF ANY. '"" ...0 EASEMENTS, COVENANTS; OR RESTRICTIONS 1414�11�vs7 WHICH DO NOT APPEAR ON THE RECORDED SUBDI- VISION PLAT. UNDER NO CIRCUMSTANCES SHOULD F6` lsX •_ L5- a" g ANY DATA HEREON BE USED FOR CONSTRUCTION OF FENCE LINES, OR FOR ESTABLISHING BDUND-kixjal ��' WNs ARY LINES. Di?A���