Municipality of Anchorage
On -Site Water and Wastewater Section • (907) 343-7904 Page 1 of 3
ON -SITE WASTEWATER INSPECTION REPORT
Permit Number: OSP231402 PID Number: 020-281-58
Dwelling: 9 Single Family (SF) ❑ with ADU ❑ Duplex (D) ❑ Two Single Family Project: ❑ New 9 Upgrade
Name
KYUNGA ROSE ABSORPTION FIELD
Site Address ❑ Deep Trench 10 Wide Trench ❑ Bed ❑ Mound
6101 GREECE DRIVE *ANCHORAGE, AK ❑ Other
Phone Number of Bedrooms Soil Rating Total depth from original grade
907-830-9988 4 2.0 GPD/SF **9 Ft.
LEGAL DESCRIPTION Depth to pipe invert from original grade Gravel depth beneath pipe
Subdivision Block Lot SEE DWG. Ft. 4.07
POTTER HIGHLANDS PHASE 1; BLOCK 1, LOT 6 Fill added above original grade Gravel length Ft.
Township Range Section SEE DWG. Ft. 31 Ft.
N/A Gravel width Beds: Number of Lines Distance between lines
SEPARATION DISTANCES 5 Ft. - - Ft.
To Septic Absorption Holding Sewer Total absorption area Number of trenches Dist. between trenches
From
Tank Field Lift Station Tank Line 300+ Ftz 1 12'+
Ft.
Well — **50'+ *50'+ Septic S.T.E.P. Holding Other
- 25'+ Manufac[I❑ El
Capaci
Surface Water _ *50'+ *50'+ — Gal.
Material Number of compartments
Lot Line _ 1 0'+ 1 0'+ - NA
Foundation _ 1 0'+ 10'+ - LIFT STATION
Manufacturer Capacity
Remarks *ORENCO AWWTS ANCHORAGE TANK 115 Gal.
**OVER EXCAVATED - SEE ATTACHED EMAIL Alarm location Electrical installed by
REMOTE MONITORING DRS
PIPE MATERIAL House to tank EXISTM Tank to D 1785
Installer drainfield
JR'S SEPTIC Drainfield D3034 CO/MTD3034
Inspector GEG AND M.O.A. BENCH MARK (Assumed elevation) 100.00 ft
Inspection 1,' 3/13/2024 2�e 3/13/2024 Location and description
da:3'd 3/14/202 4'" - TOP OF M H 1
ON -SITE WATER AND WASTEWATER SECTION APPROVAL Engineer's Stamp
oQ6o�p
Conditional Approval: Date �oP��• .
9�,40oD
0
..: .4 , `� •.
Septic System ao /e re A. Ga Hess. O�
Approved Date 31i 2� 2 0
0 s cE-s 00
q, 1.2q-
Note: this approval does not include well permit requirements. ttaecc �0oos'%00
(Rev 05/02118)
PERMIT NUMBER:
OSP231402
A I B
PV
14.9
46.1
C01
44.5
32.6
MT1
46.0
32.0
CO2
65.6
62.5
MT2
63.7
61.4
NO+E: PIPE LOCATIONS ARE
SHOWN PER GEG SHOTS
TAKEN WITH LEICA DISTO
RECORD DRAWING PARCEL NUMBER:
DRAWING V 020-281-58
PARADISE VALLEY; BLOCK 2, LOT 20 1
POST CONSTRUCTION GRADE APPEARS TO PROVIDE
DRAINAGE IN TANK/POD AREA. HOWEVER, ADDITIONAL
GRADING MAY BE RQUIRED IN THE SPRING/SUMMER OF 2024
(UNDEVELOPED)
10' UTILITY EASEMENT —
S910 LASER DISTANCE 3T SECTION LINE EASEMENT
METER. SWING -TIES TO
HOUSE CORNERS WERE _
GEN RATED IN AUTOCAD�
2015 DRAINFIELD - CONTRACTOR
BURIED CLEANOUT
C(
"MT2�
1 �
PUMP VAULT\ PLUMBED WITH TWO SEPARATE
DROP CONNECTS; ONE TO THE 2015 DRAINFIELD
AND ONE TO THE NEW 2024 DRAINFIELD
\ I11
c
I
0 �tiF I
Rio/G h
441
S /
/ Q
r'
\\—APPR(
A
��-� '' •'� •~ r �.> EXISTING 4
DRIVEWAY .. BEDROOM HOUSE
i
PARKING
/ 1
I 50' WELL RADIUS
I I
1 �
NEW DRAINFIELD
LOCATION OF EXISTING TANK AND TREATMENT POD
GARNESS ENGINEERING GROUP, Ltd
ENGINEERING SALES CONSULTING -
3701 E. TUDOR ROAD, SUITE 101 'ANCHORAGE. AK 99507 • PHONE (907) 337E779 • FAX (907) 330-3246 • WEBSITE: —gam—engineering—m
PREPARED FOR: PHONE NUMBER: PAGE NUMBER:
KYUNGA ROSE 907-830-9988 2 OF 3
LEGAL DESCRIPTION: DRAWN BY:
POTTER HIGHLANDS PHASE 1; BLOCK 1, LOT 6 D.J.G.
TYPE OF WORK: DATE:
SITE PLAN RECORD DRAWING 3/27/2024
N
i * • 49 * ♦•♦i
..................,
0
0. t. ............ .0
orey arness : �� =
CE-795 ?:
LICENSE 44" :\\FE S\\'•� ••
#AECC884 /
PERMIT NUMBER: RECORD DRAWING PARCEL ID NUMBER:
GSP231402 020-281-58
TOP OF PUMP VAULT = 100.36 THERE ARE TWO PITILESS ADAPTERS IN THE
PUMP VAULT; ONE TO THE 2015 DRAINFIELD
AND ONE TO THE NEW 2023 FIELD
FROM AX POD
PIPE INVERT AT INLET = 97.23 TO DRAINFIELD/S
Qz
BOTTOM OF PUMP VAULT = 92.32
MT CO FINAL GRADE = 105.89-106.17
ORIGINAL GRADE AT HIGHEST POINT = 106.45
2" INSULATION PER CONTRACTOR
TH#1 BY STEVE
PANNONE,PE
FILTER FABRIC
ZOO
'e
e
e
4.07' "o
INVERT OF PIPE = 102.52
0
s
s
e
=.:,z MOA SAND r k. BOTTOM OF TRENCH/TOP OF SAND = 98.45
RELATIVE ELEVATION OF BOTTOM OF T.H. = 88.45 I� 5' �I BOTTOM OF EXCAVATION = 97.45
(TH#1 DRY ON 2/20/2015)
THE CONTRACTOR (JR'S SEPTIC) OVER EXCAVATED THE TRENCH DURING CONSTRUCTION. PER THE DESIGN, THE MAXIMUM DEPTH OF
EXCAVATION WAS 8 FEET. HOWEVER, THE CONTRACTOR EXCAVATED 9 FEET BELOW THE HIGHEST ORIGINAL GRADE. ATTACHED WITH
THIS RECORD DRAWING/S IS AN EMAIL REQUESTING APPROVAL FROM THE MOA TO ALLOW THE MAXIMUM DEPTH OF EXCAVATION TO BE
9' BELOW GRADE. THIS EMAIL WAS VERBALLY DISCUSSED WITH M.O.A. ONSITE EMPLOYEE CURTIS TOWNSEND, P.E. ON 3/13/2024 AND GEG
WAS GIVEN VERBAL APPROVAL BY THE MOA TO HAVE THE SYSTEM INSTALLED WITH A MAXIMUM DEPTH OF EXCAVATION OF 9 FEET.
•••`,�`c94♦
GARNESS ENGINEERING GROUP, Ltd ......::....... ........I����•������.
.. :..... ;
ENGINEERING SALES CONSULTING — 0`� 1��
3701 E. TUDOR ROAD, SUITE 701'ANCHORAGE, AK 99507 • PHONE (907) 337-6179 • FAX (907) 338-3246 - WEBSITE: wxvi.gamessengineering.com %. .. j. \ ..... ..y ....:. .
PREPARED FOR: PHONE NUMBER: PAGE NUMBER: JJi]
KYUNGA ROSE 907-830-9988 3 OF 3 ♦♦ '1� �ffrey A. G�rness
AV
LEGAL DESCRIPTION: DRAWN BY: ♦#♦;���•••• 3r.9(�. ��..
POTTER HEIGHTS PHASE 1; BLOCK 1, LOT 6 D.J.G.
TYPE OF WORK: DATE: LICENSE 0I;:;`S` \Cj\' �•
SEPTIC SYSTEM PUMP VAULT AND DRAINFIELD PROFILE 3/18/2024 #AECC884
20' WALKWAY EASEMENT
N 89 53'26" E297.90
PROPERTYLINE
MUNICIPALITY OF ANCHORAGE
On -Site Water & Wastewater Program
PO Box 196650 4700 Elmore Road
Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997
http://www.muni.org/onsite
On -Site Wastewater Disposal System Permit
Permit Number: OSP231402
Work Type: Septic Upgrade
Tax Code Number: 02028158000
Site Legal Address: POTTER HIGHLANDS PH 1 BLK 1 LT 6 G:3638
Site Mailing Address: 6101 GREECE DR, Anchorage
Owner: ROSE KYUNGA L
Design Engineer: GARNESS ENGINEERING GROUP LTD
This permit is for the construction of:
Effective Date:
Expiration Date
Lot Size in Sq Ft:
Total Bedrooms:
12/19/2023
12/18/2024
66559
Q Disposal Field ❑ Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage
All construction shall be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80)
3. The wastewater code requires inspections during the installation. The engineer shall notify the Development
Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
shall be either:
a. Opened and Closed on the same day, or
b. Covered, sealed, and heated to prevent freezing
Received By: Ins 5'j V C7 e-c)
Issued By:
Date:
Date: ( 1 3
S
Development Services Department Phone: 907-343-7904
On -Site Water & Wastewater Section - ` Fax: 907-343-7997
ON -SITE SEPTIC/WELL PERMIT APPLICATION
Parcel I.D. 020-281-58
Property owner(s) KYUNGA ROSE
Mailing address 6101 GREECE DRIVE *ANCHORAGE, AK
Site address 6101 GREECE DRIVE *ANCHORAGE, AK
Day phone 907-830-9988
Legal description (Sub'd., Block & Lot) POTTER HIGHLANDS PHASE 1; BLOCK 1, LOT 6
Legal description (Township, Range & Section)
Lot Size
Sq. Ft.
Number of Bedrooms 4
APPLICATION IS FOR: APPLICATION IS AN:
TYPE OF DWELLING:
(® all that apply)
Absorption Field ❑ Initial ❑
Single Family (SF) I -XI
Septic Tank ElUpgrade RX
(w/wo ADU)
Holding Tank ❑ Renewal ❑
Duplex (D) El
Privy ❑
Multiple Dwellings ❑
(SF and/or D)
Private Well ❑
Water Storage ❑
THIS APPLICATION INCLUDES A WAIVER REQUEST FOR:
Distance:
I certify that the above information is correct. I further certify that
this is in accordance with
applicable Municipal Codes.
(Signature of property owner or authorized agent)
Permit/Rush Fees: .5 Waiver Fees:
Date of Payment: Date of Payment:
Receipt Number: Receipt Number:
Permit No. D:3) P o Waiver No.
GADevelopment Services\Building Safety\On Site Water and WastewatefformsUient FormsTermit Application.doc
96
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP231402, Curtis Townsend, 12/19/23
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP231402, Curtis Townsend, 12/19/23
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP231402, Curtis Townsend, 12/19/23
-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
20' WALKWAY EASEMENT
N 89 53'26 " E297.90 FROPERTY'LINE
-Zzl
Municipality of Anchorage
Community Development Department Page 1 of 3
On -Site Water and Wastewater Program
4700 Elmore St. • P.O. Box 196650 Anchorage, AK 99519-6650 • http://www.muni.org/onsite • (907) 343-7904
ON-SITE WASTEWATER INSPECTION REPORT
Permit Number: OSPI51040 PID Number: 020-281-58 ❑✓ New ❑ Upgrade
Name:
Potter Creek Development LLC
ABSORPTION FIELD
R1 Deep Trench ❑ Shallow Trench ❑ Bed ❑ Mound
Address
3230 C Street, First Floor, Anchorage, AK 99503
❑ Other
Phone
Number of Bedrooms
Soil Rating
Total depth from original grade
4
4 GPD/SF
12.0 Ft.
LEGAL DESCRIPTION -
Depth to pipe invert from original grade
6.0 Ft.
Gravel depth beneath pipe
6.0 Ft.
Subdivision - Block Lot -
Potter Highlands Phase l 1 6
Fill added above original. grade "Gravel
0 Ft.
length -
-20.0 Ft.
Township -Range Section
Gravel width -
3.OFt.
Beds: Number of Lines
NIA
Distance between lines
N/A Ft.
SEPARATION DISTANCES
To
Septic
Absorption
Holding
Sewer
Total absorption area
Number of trenches
Dist. between trenches
From
Tank
Field
Lift Station
Tank
Line
240 Ftp
1
- NIA Ft.
Well
124.1
141.1
124.1
N/A
112:1
TANK [:]Septic p S.T.E.P. [:]Holding ❑ Other
Manufacturer
Anchorage Tank/ Orenco
Capacity
I 1,5000al.
Surface Water
100+
100+
100+
N/A
Material
Plastic
Number of compartments
2
-
Lot Line
60.4
66.2
60.4
N/A
NA
Foundation
15.9
33.7
15.9
N/A
LIFT STATION
Manufacturer
Orenco
Capacity
500 Gal.
Curtain Drain
N/A
NIA
N/A
N/A
Pump on level at -
Pump off level at
High water alarm at
Remarks
43 in.
40 in.
45 in.
-
Pump make and model
P2005
- Electrical Inspections performed by
PIPE MATERIAL House to tank 3034 Tank to
drairirield 3034
Installer -
John Hagmeier Homes
Drainfield 3034 CO/MT 3034
Inspector Pannone Engineering Services LLC
BENCH MARK (Assumed elevation) 100ft
Inspection1" 1018/2015 m 10/8/2015
Location and description
dates:2
Garage FF
V 10/9/2015 4'"
COMMUNITY DEVELOPMENT DEPARTMENT APPROVAL
Engineer's Stamp
Conditional Approval: Date
'gsp,�9
%.`P'
loco yk
Seven annoras
8149
Approved Date*/97
Inspection Report_-12.doc
SEPTIC AREA (E) �
10' T&E EASEMENT i
T T
'I 33' SECTION LINE EAS EMEK _
1 RESERVE DRAINFIELD (P) / W� '
20LF x 3'W x 6'ED x 12'TD i /
C2 .
A/0 Z.d R1VEWgy B
I {
NEW
413R
t
of sce7iC. HOUSE'!
NEW WELL
�I r
l
' ) r
51.2�"1
B
M2'
15.121.5
kDCO
NEW PRIMARY DRAINFISLD
29.8
41.8
12 0 m
; 2OLF x 3'W x 6'ED x 12'TD
38.2
TH
M 1
M1
37.6
45.6
C2
55.4
w !
T1 -
54.4
DCO
w
M, FC
i
- NEW 1500g ADVANTEX TANK WITH
/•
60.8
%
AX20 POD AND DCO
D A
A/0 Z.d R1VEWgy B
I {
NEW
413R
t
of sce7iC. HOUSE'!
NEW WELL
�I r
l
' ) r
NOTES: PANNONE ENG SVC, LLC of q'\�\ Dole
RECORD DRAWING .. . C•9s,�� 0/12/2015
P.O. BOX 100217 ANCHORAGE, AK 99510 J
PHONE (907) 272-8218 FAX (907) 272-8211 /%g�p �y11 Scale 50
/*:49 •*�
........ .. ... .. P.I.D. NO
POTTER HIGHLANDS PHASE I, BLOCK 1, LOT 6.... 020-281-58
JOHN HAGMEIER /HAGMEIER HOMES
Steven R_ Pannone PERMIT NO.
-p CE 8149
1 �/ OSP151040
GREECE CIR. f � •fir
PLAN ANCHORAGE, AK 99516 ���i °FOo Sso0` sheet
A
B
15.121.5
kDCO
34.4
29.8
41.8
33.7
38.2
36.9
43.5
M1
37.6
45.6
C2
55.4
63.3
M2
54.4
63.4
C
D
WELL
76.7
60.8
NOTES: PANNONE ENG SVC, LLC of q'\�\ Dole
RECORD DRAWING .. . C•9s,�� 0/12/2015
P.O. BOX 100217 ANCHORAGE, AK 99510 J
PHONE (907) 272-8218 FAX (907) 272-8211 /%g�p �y11 Scale 50
/*:49 •*�
........ .. ... .. P.I.D. NO
POTTER HIGHLANDS PHASE I, BLOCK 1, LOT 6.... 020-281-58
JOHN HAGMEIER /HAGMEIER HOMES
Steven R_ Pannone PERMIT NO.
-p CE 8149
1 �/ OSP151040
GREECE CIR. f � •fir
PLAN ANCHORAGE, AK 99516 ���i °FOo Sso0` sheet
SPECIAL PROVISIONS TO SPECIFICATIONS
1. ALL CONSTRUCTION WAS INSTALLED AS SPECIFIED IN THE MOST CURRENT EDITION OF THE MUNICIPALITY OF ANCHORAGE
STANDARD SPECIFICATIONS (MASS) FOR COMPONENT PARTS AND MATERIALS USED IN CONSTRUCTION OF ON—SITE
WASTEWATER DISPOSAL SYSTEMS AND ATTACHED SPECIAL PROVISIONS.
2. SCOPE OF WORK: INSTALLED NEW 1500g S.T.E.P. TANK WITH AX20 POD AND DOUBLE CLEAN OUT AND SOIL ABSORPTION
SYSTEM. INSTALLED NEW WELL
3. GROUNDWATER WAS NOT ENCOUNTERED TO A DEPTH OF 18 FEET BELOW EXISTING GRADE AS EVIDENCED BY THE SOIL
TEST HOLE-. AN APPARENT WATER TABLE WAS NIOT OBSERVED IN ANY OF THE EXCAVATION_ S LESS THAN 18 FEET BELOW
EXISTING GRADE.
TH-1
O 7
O O
2
�W W
O� U
U
102.2
FILTER FABRIC
4"
R:
DRAIN PE d-4
DRAIN ROCPI
K 6" ABOVE PIPE INV
6..0
96.2
6,0 DRAIN ROCK
R -90.2
6 G SECTION
84.2
(PRE ASSEMBLED)
1500a ADVANTEX
Z
O wo
m
h ti
r mZ
Q
O ¢
p
�=
MHOR
J O
AA
p �
96.2
NOTES:
PROFILEx
LLC
99510
272-8211
DRAWING
�=
MHOR
90.2 -
's
__
- 90.2
TRENCH SEE DESIGN
ABBREVIATIONS
CU
COPPER
DIP
DUCTILE IRON PIPE
DESIGN PARAMETERS
TH
TEST HOLE
PRIMARY SEPTIC SYSTEM
FC
FOUNDATION CLEAN OUT
NO. BEDROOM: 4 (600 gpd)
LEGEND
T#
TANK CLEAN OUT NO.
TANK SIZE: 1500 ADVANTEX
W
WATER LINE/
C#
CLEAN- OUT NO.
W/ AX20 POD AND DCO
WELL RADIUS
M#
MONITOR TUBE N0.
PERC RATE: 15.6 MPI
R. 1.
RIGID INSULATION
SOIL RATING: 4 GPD/SF
-
_
DCO
DOUBLE CLEAN OUT
AREA ROD: 150 SF
SS
-- NEW SEPTIC
DV
ER VALVE
SYS. TYPE: DEEP TRENCH 6.0'ED
-
- FS
F
FLOW SPLITTER
LOW
MIN LENGTH: 12.5 LF
-
BFG
BELOW FINISH GRADE
USED:
OG
ORIGINAL GRADE
-GRADE
20 LFx3.0'Wx6.0' E.D., 12.0' TD
FG
FINISH
TOTAL AREA: 240 SF
TS&V
TOPSOIL AND VEGETATE
NIC
NOT IN CONTRACT
NOTES:
PANNONE ENG SVC,
P.O. BOX 100217 ANCHORAGE, AK
PHONE (907) 272-8218 FAX (907)
LLC
99510
272-8211
DRAWING
POTTER HIGHLANDS PHASE I, BLOCK 1, LOT 6
JOHN HAGMEIER / HAGMEIER HOMES
GREECE CIR.
DESIGN DETAILS ANCHORAGE, AK 99516
2/20151
NTS
... .... .... ..:.. P.I.D. NO
020-281-58
Stev R. onnone PERMIT N0.
CE 8149 .'��� OSPI51040
F'••......''F Sheet
ll>\ DPROFESSIOdP`�: 3 OF 3
Alpine Drilling & Enterprises
Well Log
Permit Number: ffSW151040 Date of issue: 3-06-15 Parcel Identification Number: 02028153000
Date Started: 3-09-15 Date Completed: 3-10-15 Is well located at approved permit location? x Yes ❑ No
Legal Description: Potter Highlands Phase 1 Block 1 Lot 6
Property Owner Name & Address: Potter Creek Development LLC
3230 C Street First Floor
dnchnranA Atacka 99.503
Method of Drilling ❑ air rotary ❑ cable tool
Borehole Data: Depth (ft)
Soil Type, Thickness & Water Strata
From
To
Casing type: steel
Stick -asp
Organics & silt
0
2
2
3
Wall Thickness: .250 inches
Diameter: 6 i::ches Depth: III feet
Liner Type:
Gravelly silt
3
9
Diameter: inches Depth: feet
silty gravel
9
14
Casing stickup above ground: 2 feet
Static water level (from ground level): 121 feet
gravelly silt 14 47
silt
grme .y stt
r
47
49
49
o�
w
Pumping level: 220 feet after
rn
2 hos pumping b gpm „
Recovery Rate: 8 gpm I
san4v silty gravel
86
92
Method of Testing: air�li;r
gravelly silt
92
104
Well Intake Opening Type:
bedrock
194
226
❑ Open End x Open Hole
❑ Screened Start feet Stopped _ feet
❑ Perforations Start feet Stopped feet
H2O
181
,1J
Grout Type: bentonite granules Volume: 1 b
De the Start 0 feet Stopped ? feet
Pump: Intake Depth feet
Pump size hp Brand Name
Well Disinfected Upon [ ompietion? x Yes ❑ No
Method of Disinfection: chlorine tablets
WATER QUALITY TESTING
(_
Comments:
Comm l
CCU100ML
Well Driller: Alpine Drilling & Enterprises
Nitrates I , C9 A
111g/L
I�
On, Box 170496
Arsenic
ug/L
Anchorage, Alaska 99511 AK Zip
Pump Installation Date: 7!2112015
Pump Intake Depth Below Top of Well Casing: 212 feet
Pump Manufacturer's Name: Goulds
Pu nip Model: 10SB10
Pump Size 1 hp
Pitless Adapter Bttrial Depth; 12 feet
Pitless Adapter>Vlianufacturer's name: 6larinson
P;i fees Ada to S•t,tHe arnw PJl?p F Weli S.,,,j
Well Disinfected Upon Completion.? L� yes ❑ !io
Method of Disinfection: chlorine tablets
Comments:
Pump Installer Name: Aarow Pump & Well Service, LLC
P.O. Box 110496
Anchorage, AK 99511-0496
Please save for your engineer.
This is needed for your COSA.
Attention: The pump installer shalt provide a pump installation log to the DSD within 30 days of pump installation.
Development Services Department
Building Safety Division
I
On -Site Water &Wastewater Program
4700 Elmore Pond
'-
P.O. Box 196650
MarkBegich
Anchorage, AK 99507
Mayor
www-muni.org/onsite - -
(907) 343-7904
Pump Installation Log
Well Drilling Permit Number: SW 151040 Date of Issue: 3-06-15
Parcel Identification Number: 00281580002
Legal Description
Property OFvteer Name & Address:
Potter Highlands Phase 1 Block 1 Lot 6
Potter Creek Development LLCPHagmeier Homes
3236 C Street First f=loor
-
Anchorage, Alaska 99503
Pump Installation Date: 7!2112015
Pump Intake Depth Below Top of Well Casing: 212 feet
Pump Manufacturer's Name: Goulds
Pu nip Model: 10SB10
Pump Size 1 hp
Pitless Adapter Bttrial Depth; 12 feet
Pitless Adapter>Vlianufacturer's name: 6larinson
P;i fees Ada to S•t,tHe arnw PJl?p F Weli S.,,,j
Well Disinfected Upon Completion.? L� yes ❑ !io
Method of Disinfection: chlorine tablets
Comments:
Pump Installer Name: Aarow Pump & Well Service, LLC
P.O. Box 110496
Anchorage, AK 99511-0496
Please save for your engineer.
This is needed for your COSA.
Attention: The pump installer shalt provide a pump installation log to the DSD within 30 days of pump installation.
On -Site Water & Wastewater System Permit
MUNICIPALITY OF ANCHORAGE
Development Services Department
On -Site Water & Wastewater Program
4700 Elmore Road, PO Box 196650
Anchorage, AK 99519-6650
Telephone: (907) 343-7904
Permit Number: OSP151040
Tax Code Number: 02028158000
Work Type: WellSeptic Initial
Permit Effective Dates: March 06, 2015 to March 05, 2016
Design Engineer: PANNONE ENGINEERING SERVICE
Subdivision: POTTER HIGHLANDS PH 1
Site Legal Address: POTTER HIGHLANDS PH 1 BLK 1 LT 6 G:3638
Owner/Address: POTTER CREEK DEVELOPMENT LLC
3230 C ST FIRST FLOOR ANCHORAGE AK 995030000
Site Mailing Address: Lot Size in Sq Ft: 66559
Total Bedrooms: 4
This permit is for the construction of:
Y Disposal Field Y Septic Tank N Holding Tank N Privy Y Private Well N Water Storage
All construction must be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater
Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80).
3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services
Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either:
A. Open and Close on the same day.
B. Covered, sealed, and heated to prevent freezing.
Receive
Issued
d By: Date:
BY Date:3
MUNICIPALITY OF ANCHORAGE
6
Community Development Department Phone: 907-343-7904
Development Services Division Fax: 907-343-7997
On -Site Water & Wastewater Program
ON-SITE SEWER/WELL PERMIT APPLICATION
Parcel I.D. 020-281-58
Property owner(s) John Hagmeier Homes LLC
Mailing address 2204 Cleveland Avenue #201,
Site address Greece Cir
Day phone
Anchorage, AK 99517
Legal description (Sub'd., Block & Lot). Potter Highlands Phase I, Block 1, Lot 6
Legal description (Township, Range & Section)
Lot Size 66,559 Sq. Ft. Number of Bedrooms 4
APPLICATION IS FOR:
APPLICATION IS AN:
TYPE OF DWELLING:
(® all that apply)
Absorption Field
❑X
Initial ❑x
Single Family (SF)
❑X
Septic Tank
❑X
Upgrade ❑
(w/wo ADU)
Duplex (D)
❑
Holding Tank
❑
Renewal ❑
Multiple Dwellings
❑
Privy
❑
(SF and/or D)
Private Well
❑x
Water Storage
❑
THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR:
Distance:
I certify that the above information is correct. I further certify that this is in accordance with
applicable Municipal Codes.
Permit/Rush Fees: 661+-9/5- = 7e /� Waiver Fees:
Date of Payment: 9-IdD /5 Cjk- Date of Payment:
Receipt Number: 01-21-)c Receipt Number:
Permit No. Mris iloyo Waiver No.
Permit App_= :;
Pannone Engineering Services LLC
Steven R. Pannone, Principal
Registered Professional Engineer
E-mail: steveCtoanenaak.com
February 20, 2015
Municipality of Anchorage
Development Services Department
On -Site Water & Wastewater Program
4700 Elmore Road
P. O. Box 196650
Anchorage, Alaska 99519
Subject: Potter Highlands Phase I, Block 1, Lot 6
Septic System Permit Request
Ladies and Gentlemen:
I am writing to request a permit to install a new septic system be issued for this property. The proposed
systems will serve a proposed four (4) bedroom house. Currently the lot is undeveloped. The proposed
system will utilize a 1500g S.T.E.P. tank with AX20 Pod and auxiliary pump vault. The surrounding
developed lots are served by private wells. There are no wells on surrounding lots within 100 feet of this
system and there are no septic systems installed on the surrounding lots within 100 feet of the proposed
well.
Soils. One test holes was performed on this lot by Pannone Engineering Services in February of 2015, and
groundwater was monitored for seven days. Ground water was not observed below the surface in the test
hole monitor tube in February of 2015. Bedrock was not encountered in the test hole. It is my opinion,
based on the results of the percolation tests and overall soils appearance; an application rate of 4.0
gallons/day/square feet should be used for a CAT III wastewater system.
1. Soil Absorption System Design.
a. See Sheet 2 of the design package.
2. Surface Water: There is no surface water within 100 feet of the proposed septic tank and drain
field. The proposed drain field upgrade will maintain at least 100 feet from all surface water and drainage
ditches.
3. Topography: The existing topography slopes from the east to west at approximately 20%-25% in
the area of the proposed drain field. There are no steep slopes within 50' of the proposed drain field. The
proposed drain field will maintain 50' separation all steep slopes, including the road cut slope to the west.
Mailing: P.O. Box 100217, Anchorage, AK 99510-0217
Physical: 332 East Manor, Anchorage, AK 99501
Telephone: (907) 272-8218 FAX: (907) 272-8211
Page 2 of 2
4. Drawing Markings: The Drawings are marked "For MoA Review Only". When written notification
that the review is complete and that there are no further comments is received from MoA On -Site
Department, the note will be removed and 'Issued for Construction" drawings will be issued.
The proposed installation will not affect the future development of the surrounding or existing lots. There
are no surrounding wells within 100 feet of the proposed septic location.
If you have any questions or concerns, please contact me at 272-8218.
Sincerely,
Steven R. Pannone, P.E.
Owner/Civil Engineer
Mailing: P.O. Box 100217, Anchorage, AK 99510-0217
Physical: 332 East Manor Ave, Anchorage, AK 99501
Telephone: (907) 272-8218 FAX: (907) 272-8211
I
\ \ I\ t
{, SEP\TIC AREA (E)
`
00
2
W
r �— 10' T&E EASEMENT 7
47,7 33' SECTION LINE EASEME kk
!! i
-`
52.4f'
I - I
k2,
PRIMARY /RESERVE DRAINFIELD (P)
i 2,0 20LF x 3'W x 6'ED x 12'TD 1/
i w I TH-1
IM--` - 1500g ADVANTEX TANK WITH /
;�
yM M
AX20 POD AND DCO (P) I,
HOUSE�.�
(P)
LOVIS
DR1VEw
NO pY i
T 0 eNCR �C MON OCBY 0TH
S P ERg I
1l /
WELL (P)
\ ,M ,
NOTE
Dcte
FOR CONSTRUCTION - PANNOoNE7 ENGANCHORAGE,CK 99 LO ,,- (� QF• aCq�sl,i /s/zols
PHONE (907) 272-8218 FAX (907) 272-8211 %�P: �9�� stole
PLAN
POTTER HIGHLANDS PHASE I, BLOCK 1, LOT
JOHN HAGMEIER / HAGMEIER HOMES
GREECE CIR.
ANCHORAGE, AK 99516
*."�� P.LD NO
.....••� % 020-281-58
�teveCE 8149 an PERMIT -NO.
FESSIOS>P�'� ��/
Sheet 1040
SPECIAL PROVISIONS TO SPECIFICATIONS
1. ALL CONSTRUCTION SHALL BE INSTALLED PECIFIED IN THE MOST CURRENT EDITION OF THE MUNICIPALITY OF
ANCHORAGE STANDARD SPECIFICATION AS FO COMPONENT PARTS AND MATERIALS USED IN CONSTRUCTION OF
ON-SITE WASTEWATER DISPOSAL SY EM AN ATT ED SPECIAL PROVISIONS.
Ad�a�
2. SCOPE OF WORK: INSTALL NEW 15 AX20 POD AND DOUBLE CLEAN OUT AND SOIL ABSORPTION
SYSTEM. INSTALL NEW WELL Q�J'
3. GROUNDWATER WAS NOT ENCOUNTERED TO A DEPTH OF 18 FEET BELOW EXISTING GRADE AS EVIDENCED BY THE SOIL
TEST HOLE. IF AN APPARENT -WATER TABLE IS OBSERVED IN ANY OF THE EXCAVATIONS LESS THAN 18 FEET BELOW
EXISTING GRADE NOTIFY THE ENGINEER IMMEDIATELY.
NOTES: PANNONE ENG SVC, LLC
CONSTRUCTION P.O. BOX 100217 ANCHORAGE, AK 99510
PHONE (907) 272-8218 FAX (907) 272-8211
POTTER HIGHLANDS PHASE I, BLOCK 1, LOT 6
JOHN HAGMEIER / HAGMEIER HOMES
GREECE CIR.
DESIGN DETAILS ANCHORAGE, AK 99516
Vr H ^
3/4/2015
TH-1
..D. NO
020-281-58
FILTER FABRIC
PERMIT N0.
OSP151040
CU
-z.o
OR/
OL
4" 0 DRAIN PIPEI� . ti 7 7
r--�rc�,l,i
DUCTILE IRON PIPE
DESIGN PARAMETERS
TH
6.0
DRAIN RDCK 6" A9CVE PIPE INV f�
FC
FOUNDATION CLEAN OUT
NO. BEDROOM: 4 (600 gpd)
LEGEND
T#
TANK CLEAN OUT N0.
TANK SIZE: 1500 ADVANTEX
W WATER LINE/
C)/
CLEAN OUT NO.
W/ AX20 POD AND DCO
M#
MONITOR TUBE NO.
0
6 G
DRAIN ROCK _
RIGID INSULATION
SOIL RATING: 4 GPD/SF -
m/
DOUBLE CLEAN OUT
AREA ROD. 150 SF
SS NEW SEPTIC
DV
ER VALVE
SYS. TYPE: DEEP TRENCH 6.0'ED
SECTION
MIN LENGTH: 12.5 LF -
FS
60
-
BEG
BELOW FINISH GRADE
USE:
GG
ORIGINAL GRADE
20 LFx3.0'Wx6.0' E.D., 12.0' TD
-18.0
FG
FINISH GRADE
TOTAL AREA: 240 SF
z
10
Q o
s
a
-
z
o
w
m
oa
w
m
�w
ww z
z
?
W
NOTES: PANNONE ENG SVC, LLC
CONSTRUCTION P.O. BOX 100217 ANCHORAGE, AK 99510
PHONE (907) 272-8218 FAX (907) 272-8211
POTTER HIGHLANDS PHASE I, BLOCK 1, LOT 6
JOHN HAGMEIER / HAGMEIER HOMES
GREECE CIR.
DESIGN DETAILS ANCHORAGE, AK 99516
Vr H ^
3/4/2015
ALftiKtVIAIIUNJ
..D. NO
020-281-58
..... ... .. ..
Steven R. Pannone
�1PFc. CE 8149 ,.rte/
1
+tkkF' PROFES9�PT"��"
i\11 �'
PERMIT N0.
OSP151040
CU
COPPER
DIP
DUCTILE IRON PIPE
DESIGN PARAMETERS
TH
TEST HOLE
PRIMARY SEPTIC SYSTEM
FC
FOUNDATION CLEAN OUT
NO. BEDROOM: 4 (600 gpd)
LEGEND
T#
TANK CLEAN OUT N0.
TANK SIZE: 1500 ADVANTEX
W WATER LINE/
C)/
CLEAN OUT NO.
W/ AX20 POD AND DCO
M#
MONITOR TUBE NO.
PERC RATE: 15.6 MPI
WELL RADIUS
R.I.
RIGID INSULATION
SOIL RATING: 4 GPD/SF -
DCO
DOUBLE CLEAN OUT
AREA ROD. 150 SF
SS NEW SEPTIC
DV
ER VALVE
SYS. TYPE: DEEP TRENCH 6.0'ED
-
MIN LENGTH: 12.5 LF -
FS
FLOW SPLITTER
FLOW
-
BEG
BELOW FINISH GRADE
USE:
GG
ORIGINAL GRADE
20 LFx3.0'Wx6.0' E.D., 12.0' TD
-
FG
FINISH GRADE
TOTAL AREA: 240 SF
TS&V
TOPSOIL AND VEGETATE
-
-
NIC
NOT IN CONTRACT
NOTES: PANNONE ENG SVC, LLC
CONSTRUCTION P.O. BOX 100217 ANCHORAGE, AK 99510
PHONE (907) 272-8218 FAX (907) 272-8211
POTTER HIGHLANDS PHASE I, BLOCK 1, LOT 6
JOHN HAGMEIER / HAGMEIER HOMES
GREECE CIR.
DESIGN DETAILS ANCHORAGE, AK 99516
Vr H ^
3/4/2015
Scale
NITS
..D. NO
020-281-58
..... ... .. ..
Steven R. Pannone
�1PFc. CE 8149 ,.rte/
1
+tkkF' PROFES9�PT"��"
i\11 �'
PERMIT N0.
OSP151040
Sheet
2 OF 4
SOILS LOQ - PERCOLATION TEST
TIME
NET TIME
TEST HOLE 1
NET DROP
1
SLOPE
SITE PLAN I
,
1
ORGANICS/
OR/OL
---
2
ORGANIC SILTS
12:25
2
8.44
3.84
3
1 � _
TH-1�
---
4.60
/
5
LOT 2 \,
12:55
30 MIN
j
1.90
s
12:55
--
TH
'
---
s
' �
' 4BR
30 MIN
6.52
HOUSE
i
GM/ GRAY SILTY',I,i
SM GRAVEL WITH
'II
- SILTY SAND TH-2-/
10
12
4_
13
WAS GROUND WATER
SLOPE
14
ENCOUNTERED? N
15
IF YES, AT WHAT
TH
DEPT-? -DRY
X
16
r
17
DEPTH TO WATER AFTER
MONITORING? -DRY
18
DATE: 2/20/15
BOH
19
READING DATE CLOCK
WATER
DATE
PERFORMED: 2113115
PEROLATION RATE 15.6 (min/inch) PERC HOLE DIAMETER 6 inches
TEST RUN BETWEEN 4 FT AND
5 FT
COMMENTS: Test hole excavated by JOHN HAGMEIER HOMES LLC. Prec hole was presoaked.
Test run for at least one hour. Last 3 readings reported
PERFORMED BY: Steven R. Pannone, P.E. I CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE
WITH ALL STATE AND MUNICIPAL GUIDLINES IN EFFECT ON THE DATE
OF THIS TEST.
NOTES:
PANNONE ENG SVC, LLC
P.O. (OX 102954 ANCHORAGE, AK 99510
`` OF Atjh
qS ��
% �9++
03/4/2015
CONSTRUCTION
FOR
Scale
PHONE 907) 272-8218 FAX (907) 272-8211
g
*; .*. �/
�......... ..
NTS
POTTER HIGHLANDS PHASE I, BLOCK 1, LOT
/ " /
020-281-58
JOHN HAGMEIER / HAGMEIER HOMES
Steven R. Pannone
PS CE 8149
PERMIT NO.
GREECE CIR.
.. ��
+'�i�EOry?OSpNP
OSP151040
SOILS LOG
ANCHORAGE, AK 99516
meet
30F 4
TIME
NET TIME
LEVEL
READING
NET DROP
1
2!13/15
11:55
---
4.60
---
2
12:25
30 MIN
8.44
3.84
s
12:25
---
4.60
---
4
12:55
30 MIN
6.50
1.90
s
12:55
--
4.60
---
s
1:25
30 MIN
6.52
1.92
4" JIM CAP
4'• PUMP -OUT
SLIDE SECTION
OF 6•• PIPE
OVER THIS CONNECTION
TO PROVIDE
SHEER PROTECTION -
EXTEND TO
BRIDGE EXCAVATION
NOTES:
FOR CONSTRUCTION
ADVANTEX
AX20 POD
ADVANTEX DESIGN
24"
INSULATED
PASSIVE
AIR
VENT.
10 GAUGE
1500
GALLON
ANCHORAGE
TANK
ADVANTEX
TANK
PANNONE ENG SVC, LLC
P.O. BOX 100217 ANCHORAGE, AK 99510
PHONE (907) 272-8218 FAX (907) 272-8211
POTTER HIGHLANDS PHASE I, BLOCK 1, LOT
JOHN HAGMEIER / HAGMEIER HOMES
GREECE CIR.
SITE SECTION ANCHORAGE, AK 99516
w•��\\\� Date
OF. ACgsl�) 3/4/2015
/yam•...'.'1-.9 �, Scale
*. �TH .*II NTS
.... ... .. ..... P.I.D. NO
020-281-58
Steven R. Pannone PERMIT NO.
,P,,,•. CE 8149 .•,�e� nco, c, nnn
4 OF 4
MUNICIPALITY OF ANCHORAGE
Development Services Department Phone: 907-343-7904
On -Site Water & Wastewater Section Fax: 907-343-7997
Parcel I.D. 020-281-58
Certificate of On -Site Systems Approval
Expiration Date: 10/26/2024
Legal description POTTER HIGHLANDS PH 1 BLK 1 LT 6
Site address 6101 GREECE DR Anchorage AK
Current property owner(s) ROSE
X The On -site system(s) is/are approved for 4 bedrooms
Conditional approval for bedrooms, with the following stipulations:
Comments or advisories: The northern cleanout on the 2015 installed trench was
buried during installation of new trench. Advise that this be located and extended
above grade. Remote monitoring of AWWTS to be enabled once new owner
established communication service.
Original Certificate Date: 3/29/2024
This Certificate of On -Site Systems Approval (COSA) is intended to demonstrate the subject
system(s) is/are in substantial compliance with municipal code. The Municipality of
Anchorage, Development Services Department (DSD) issues COSAs based upon
representations provided by an independent professional engineer. The Municipality of
Anchorage is not responsible for errors or omissions in the professional engineer's work.
ATTACHMENTS:
COSA Checklist x Well Flow Advisory
Absorption Field Advisory Nitrate Advisory
Tank Age Advisory Arsenic Advisory
Other
COSA Approval_June 2022
RTAUNUPALITY OF
Development Services Department
On -Site Water & Wastewater Section
ANC1 0RAG
Phone. 907-343-7904
Fax: 907-343-7997
Certificate of On -Site Systems Approval Application E
e,,
1. GENERAL INFORMATION
Parcel I.D. 020-281-58
Complete legal description POTTER HIGHLANDS PHASE 1; BLOCK 1, LOT 6
Location (site address) 6101 GREECE DRIVE *ANCHORAGE, AK
Current property owner(s) KYUNGA ROSE
2. ON -SITE SYSTEMS SIZED FOR 4 BEDROOMS
Day phone 907-830-9988
3. TYPE OF WATER SUPPLY: 0 Private Well ❑ Private Well serving 2 dwelling units
❑ Private Well serving 3+ dwelling units ❑ Community Well or Public
❑ Water Storage
4. TYPE OF WASTEWATER DISPOSAL: 0 Private Septic ❑ Private Septic serving 2 dwelling units
❑ Holding Tank ❑ Community Septic or Public Sewer
5. SEPTIC TANK: ❑ Steel ❑ Plastic ❑ Concrete X Fiberglass
Age 8 - See advisory if steel older than 20 years
6. ABSORPTION FIELD: ❑ AWWTS ❑ Bed ❑ Deep Trench N Wide Trench ❑ Seepage Pit
Waiver request for:
Expedited review requested: ❑
Distance:
By applying for this entitlement, this property is subject to inspection by municipal On -site staff
to verify the accuracy of the information provided.
COSA Fee $ 2.W
Date of Payment 3 Z Z Z,c Z y
Waiver Fee $
Date of Payment
Waiver #
COSAAppIlcauon June2022
COSA Checklist
Legal Description: POTTER HIGHLANDS PHASE 1; BLOCK 1, LOT 6
Parcel ID: 020-281-58
If more than 1 well and/or septic system on lot, provide separate checklist. Structure served by this system _
A. WELL DATA
R Well log is filed with Onsite (or attached)
Date drilled 3/10/15 Total depth 226 ft
Cased to 111 ft
Sanitary seal is functioning correctly
Wires are properly protected
Casing height (above ground) in.
Date of flow test for COSA 10/26/23
Static water level at beginning of test 110.5 ft
Comments
B. TANK DATA
Measured operating fluid level in septic tank
Date of pumping *
X Required maintenance completed, if AWWTS
Comments: 'SEE ATTACHED MAINTENANCE AGREEMENT
D. ABSORPTION FIELD DATA NEW DRAINFIELD
Which system tested (date installed) NEW
❑ ALL standpipes present per record drawing
Total measured depth from grade 7.72 ft (max)
Measured depth to pipe invert from grade 3.37 ft (min)
❑ N/A — pressurized field.
X Per record drawings, field is insulated.
AN Monitor tubes go to bottom of effective.
If not, state depth into effective
❑ Presoaked required if
(Required if house vacant or field not used for more
than 30 days prior to date of test)
Gallons introduced NN/_gallons date
Any rejuvenation treatment (past 12 months) NO
If yes, enter date N/A
Well production at time of test 5.0+ gpm
Water storage tank volume N/A gallons
Well disinfected for coliform test? ❑ Yes ® No
M Coliform bacteria is Negative
Nitrate 1.79 mg/L ❑ Nitrate less than MRL (ND)
Arsenic ug/L 0 Arsenic less than MRL (ND)
Collected by GEG
Date 10/26/23
C. LIFT STATION NEW PUMP VAULT
❑ Required maintenance completed
Age of lift station years
Lift station material
Comments:
Adequacy test date NEW
Results Q Pass
Fluid depth prior to test in
Water added gal
New fluid depth - in
Elapsed time min
Final fluid depth in
Absorption rate and
FIELD STATUS — POST RECOVERY
Effective depth (per record drawings) 48 in
Effective depth used 0 in
Effective depth remaining 48 in
Comments/Deficiencies: THE CONTRACTOR BURIED THE NORTHERN CLEANOUT ON THE 2015 DRAINFIELD.
COSA Checklist June 2022
E. SEPARATION DISTANCES
From Private Well on Lot to: (Please enter distances if less than required or if community well on lot)
Septic Tank/Lift Station on Lot > 100'
*50'+
Community Sewer Manhole/Cleanout > 100'
❑Yes
if No
ft
FE-1 Yes
if No ft
Neighboring Tank > 100' Q Yes
if No
ft
Private Sewer/Septic Line > 25' Q Yes
if No ft
Absorption Field on Lot > 100' ❑ Yes
if No
*50'+ ft
Holding Tank > 100' 0 Yes
if No ft
Neighboring Absorption Fields > 100'
Animal Containment > 50' ❑O Yes
if No ft
❑i Yes
if No
ft
Manure/Animal Excreta Storage > 100'
Community Sewer Main > 75'❑ Yes
if No
ft
Q Yes
if No ft
❑ N/A — Served by Community Well (not on lot) or Public Water
From Septic/Holding Tank and Absorption Field(s) on Lot to: (Please enter distances if less than required)
Building Foundations > 10' ❑N Yes if No ft Surface Water > 100' [:]Yes if No *50'+ ft
Tank to Property Line > 5'
Field to Property Line > 10'
Water Main > 10'
Water Service Line > 10'
no Yes if No ft
Q Yes if No ft
❑i Yes if No ft
Yes if No ft
Wells on Adjacent Lots:
Private Wells > 100'
Community Wells > 200'
❑ Yes if No *50'+ ft
❑E Yes if No ft
If tank or field is under driveway comment below
F. ENGINEER'S COMMENTS
*AWWTS; SEE NOTE ON RECORD DRAWING (PAGE 2/3) REGARDING GRADING AROUND THE TREATMENT POD AND SEPTIC TANK
G. CERTIFICATION & STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based
on procedures outlined in the Certificate of On -Site Systems Approval Guidelines, indicates that the on -site water
supply and/or wastewater disposal system appears to comply with applicable Municipal and State codes,
ordinances, and regulations in effect at the time of installation, unless noted otherwise.
Name of Firm Gamess Engineering Group, LTD. (GEG) Phone 907-337-6179
Engineer's Printed Name Jeffrey A. Gamess Date
In conducting this evaluation, GEG provided an engineering evaluation of the well and/or septic system in
accordance with the guidelines and regulations established by the Municipality of Anchorage and industry
practices. The reported results describe the condition of the systems on the date/s of the evaluation.
Separation distances were measured to readily identifiable features. Hidden defects or encroachments may
exist that were not identified during the evaluation. The operational life of all wells and septic systems depend
upon a variety of variables, including (but not limited to) soil conditions, groundwater levels (that may fluctuate
during the year), quality of construction (materials and workmanship), and the water usage of the family utilizing
the system/s. These conditions can vary, and are outside the control of GEG. Satisfactory test results do not
guarantee future performance of the system/s; therefore, GEG makes no warranty (express or implied) regarding''
the future performance of the well or septic system. GEG makes no representation whether an alternative well
or septic system can be installed on the property in the event either of the current systems fail to perform
adequately in the future. The content of this report is for the sole benefit of the person/party that retained GEG
to perform the evaluation. Reliance upon the information provided in this report by any other person or party
(including subsequent property purchasers) is not authorized, nor will it confer any legal right whatsoever.
COSA Checklist June 2022
..:'. T ......y...
e1fff4V VG,Irness_
LICEMSE� V'�� pr o f e s Sion°®`�
MECC88d ���ia�i�00'��
�LNon
ANCHORAGE WELL & PUMP SERVICE, INC.
D
7640 KING STREET
ANCHORAGE, AK 99518
PH.907-243-0740
Bill To:
Kyunga Rose
6101 Greece Dr
Anchorage, AK 99516
Invoice
Invoice #: 20240605
Ship To:
Kyunga Rose
6101 Greece Dr
Anchorage, AK 99516
SALESPERSON
YOUR NO.
SHIP VIA
COL
PPD
SHIP DATE
TERMS
DATE
PG.
VanWingerden, Mark
38257
Net 30
3/21/2024
1
D.Ty.
ITEM NO.
DESCRIPTION
PRICE
DISC %
EXTENDED
TX.
PRICE
1
Service Call
SITE VISIT FOR WELL CASING
EXTENSION
1
Field Service
03/14/24 - Check system for access to well.
$258.00
100%
Customer to remove snow so that we can
proceed with work.
1
ST2-Mark
Service Tech
1
ST5-Tyler
Service Tech
Scope of Work:
EXTEND WELL CASING TO MOA
STANDARDS. FILL DEPRESSION AT WELL
HEAD. INSTALL NEW WELL CAP AND
CONDUIT. CLEAN UP WIRING. TEST ALL.
1
Field Service
03/20/24 - Upgrade well casing as bid.
$645.00
$645.00
1.5
ST2-Mark
Service Tech
1.5
ST5-Tyler
Service Tech
3
WELL CASING
6" ASTM SCHEDULE 40
$35.00
$105.00
1
WLC-ALM-952809/WTCC-E
6" ALUMINUM WELL CAP
$78.00
$78.00
4
FIT-ELC-CRL-PIP-1
PIPE-1" CARLON CONDUIT SCHEDULE 40
$3.00
$12.00
1
FIT-ELC-CRL-MAD-1
MALE ADAPTER-1" CARLON ELECTRICAL
$5.00
$5.00
1
FIT-ELC-CRL-CPL-1
COUPLER-1" CARLON
$2.00
$2.00
2
ESP-SPK-4-SP4C
4-Wire Plastic Splice/Repair Kit
$10.00
$20.00
3
CBL-FJC-12/3
CABLE-1 2/3 FLAT JACKET 31712500
$3.00
$9.00
3
CBL-UDG-OF-12/3
CABLE-12/3 UNDERGROUND OF
$3.00
$9.00
1
WELDER
WELDER RENTAL
$175.00
$175.00
6
PARTS:
BAGS FILL FOR DEPRESSION.
$12.00
$72.00
1
PARTS:
PAINT
$10.00
$10.00
SALE AMT.
$1,142.00FREIGHT
We appreciate your business. Thank you!
$0.00
SALES TAX
$0.00
TOTAL AMT.
$1,142.00
PAID TODAY
$0.00
BALANCE DUE
$1,142.00
March 21, 2024
RE: 6101 Greece Dr
To Whom it may concern,
The Advantex pump station at 6101 Greece Dr has been installed per NEC code.
If you have any further questions feel free to contact me at 907-351-5163
Thank you,
David R Stevenson
Owner
DRS Electric, LLC
18207 Stillwater Dr., Eagle River, AK 99577 907-351-5163
David Garness
From: David Garness
Sent: Wednesday, March 13, 2024 1:19 PM
To: 'Deborah Wockenfuss'; 'Townsend, Curtis L.; 'Cogger, Benjamin M.'
Cc: Jeff Garness
Subject: RE: Potter Highlands Phase 1; Block 1, Lot 6 - Inspections
Deb/Curtis,
The contractor (1R's Septic) over -excavated the trench for the subject lot by 1 foot. Per MOA records, the closest
test hole was dry to 18 feet and was performed by Steven Pannone, PE. Additionally, there is a test hole to the
north performed by Ted Moore, PE ( Lot 20) which shows no impermeable soil and/or groundwater to 14 feet. In
summary, although the drain field is over -excavated by 1 foot per the design (9 feet instead of 8 feet), it appears as
though it does not encroach upon impermeable soils and/or groundwater. It is important to note that the proposed
field is located outside of the 30' radius of both the previously mentioned test holes.
Given that the trench doesn't appear to violate MCA onsite code requirements, it seems reasonable to allow the
trench to be installed "as is" (despite being over -excavated). However, we could also have them add a foot of sand
(2 feet total) so that the bottom of the trench/top of the sand is 7 feet below grade (which is what was initially
proposed).
Please let me know how you would like them to proceed. Thank you
Sincerely,
David Garness, P.E., M.S.
Civil Engineer
Garness Engineering Group, Ltd.
3701 E. Tudor Road, Suite 101
Anchorage, Alaska 99507
Phone: (907) 337-6179
Mobile: (907) 632-4528
Website: wvvw.garnessengineering.com
MUNICIPALITY OF ANCHORAGE
ADVANCED WASTEWATER TREATMENT SYSTEM
MAINTENANCE AND REPAIR AGREEMENT
THIS MAINTENANCE AND REPAIR AGREEMENT, herein the “AGREEMENT" made and
entered into as of this 19th Day of of 20 24 , by and between
herein the “OWNER,” and the Municipality of
Anchorage, herein the “MUNICIPALITY”, in accordance with Anchorage Municipal Code
(AMC) 15.65.365. In consideration of the mutual covenants contained herein, the parties to this
Agreement agree as follows:
1. Advanced Wastewater Treatment Systems. The Municipality grants permission to the
Owner to utilize and operate an Advanced Wastewater Treatment System (AWWTS),
described as SePtic System ________ _________
March
Victoria Keams
located at (legal description)
Potter Highlands Ph 1 L 6 B 1
2. Maintenance, Repairs and Alterations.
(Owner is required to read, understand and initial each section)
Throughout the term of this Agreement, the Owner shall enter into a service agreement
with an AWWTS service and maintenance provider approved by the Municipality or the
manufacturer’s representative. The AWWTS shall be maintained in a satisfactory
condition capable of performing as designed and producing treated septic effluent in
accordance with the equipment’s approval for operation in the Municipality.
It shall be the responsibility of the Owner during the term of this Agreement to pay for all
repair(s), maintenance, adjustment(s), replacement costs, and inspection costs. This
includes an annual maintenance fee (typically $400 to $600).
Owner agrees that only maintenance and repair personnel approved by the Municipality
or the manufacturer’s representative will inspect and make any necessary maintenance,
repairs or permitted alterations to the system.
W Owner acknowledges that regular maintenance of an AWWTS reduces the potential
failure of the system, which could include sewage backup and costly repairs or drainfield
replacement.
\P
\)L
Page 1 of3(rev. 05/18/2018)
Owner acknowledges that the Municipality may request records of maintenance and
repairs from the manufacturer’s representative or maintenance provider.
Owner acknowledges that the fine for failing to maintain and repair an A WWTS may be
assessed in accordance with AMC 14.60.030.
\)^ Owner agrees to grant the Municipality reasonable access to test and inspect the
AWWTS. The Municipality will give at least 24-hour notice.
Owner agrees that any sale or transfer of title of the property will not occur without a new
Certificate of On-Site Systems Approval.
Owner agrees that the AWWTS installation and maintenance requirements as provided
by the AWWTS vendor/installer and approved by the Municipality are the governing
guidelines for the construction, maintenance and repair of the Owner’s AWWTS.
___ Owner agrees to maintain remote monitoring of the AWWTS as required by the
AWWTS approval.
3. Term. The term of this Agreement shall begin on the date of approval by the
Municipality to operate the installed system, or upon transfer of title, and shall continue
while the AWWTS is operational or until title is transferred.
4. Nonwaiver. The failure of the Municipality at any time to enforce a provision of this
Agreement shall in no way constitute a waiver of the provisions, nor in any way affect
the validity of the Agreement or any part hereof, or the right of the Municipality
thereafter to enforce every provision hereof.
5. Amendment. This Agreement shall only be amended by authorized representatives of
the Owner and Municipality. Any attempt to amend this agreement by either an
unauthorized representative or unauthorized means shall be void.
6. Jurisdiction: Choice of Law. Any civil action arising from this Agreement shall be
brought in the Superior Court for the Third Judicial District of the State of Alaska at
Anchorage. The laws of the State of Alaska shall govern the rights and obligations of the
parties under this Agreement.
7. Severability. Any provisions of this Agreement decreed invalid by a court of competent
jurisdiction shall not invalidate the remaining provisions of the Agreement.
\JC
Page 2 of3(rev. 05/18/2018)
aD
4-�
101
/ov.
-
CI
N
40,
w0
N
b
�
3
0
U
•'-
3
U �
O'D
0
zz
H
w�
Cc
r-
3
0
N .
00
0
To: Page: 6 of 9
2023.09-16 00:43:47 GMT
19073086608
From: Wes Anderson
am SSBN
4139 48
a US a mail We **IN
its as xx a
it
am so
am 115A
IN 5 *aS I a
go a 9 $**111110 a w
Sam 'a
no$$* visa
wan
[A * Tex-
Fwd maintmamw Rqwt
AnchorageTank
Unscheduled
907-272-3543
vrupe-q
Ian RoseA
hiQme $eres Tech
t5ne
$10 1 Gr"ce Drive, Anchorage AK 99518
(907) 575-6956
— — - - ---------------
Rk ,vto rE ;
I---
C'Ztv J�T'
Pod
Kt -41Q
137719
_151040
�
42216B
RTU132100-
0910712023
Diswchor Comments
Erato 0911212023 12:00 AM
Tiff" . ............................ .
Please pump the septic tank. The home is
for sale. Sooner the bsUr-
Notification of site condition
made by veelcA M"' MmitQjiN sysum
F*
made I)y Korneowner
00ter. ........ ....... ..... -.- ........... ..............
Site condition at time of *a#
F" Alarm 171'rany, oveillow
Odor alwk.p.
Cowr
Do f2A
Odor Of SaMPIO.
vicw L, C'j Eadl'v (71MO*
S'"CIP Cabbag, -I rx, My
-Corfdltlws at site
Abft On C ytz No
T nk Liquid Leval E; Noffnal CI High L] t*w
PWP, Operwitvlw? E" YOS No
Flacim .......... --'-TdPP6d On 00
On C Off
06ff
Dowm4wi tto Panel status by �v V1,6 apotop1*0
Inputs w)d oiftputs as)ndlcated by rite yellgw wtd red LEIS
input.
OQ00eO00
.
flastsfatft
(D (2) S @ —
L L� =L M
1" M ❑0 Cit C.1 f9wfifv
I
�w
-1 Cause of MAMmetion; r MW tianfoW C3 Otocemg-Re4ftd.
Smims RenderOW
sp
.. ........
Pails usetL- w WaMM(y 8 = 134we V awovAate SWOC#M)
w item Numbw
System WiOAPU4 no farther aatkm needed OAd Mionai mrwA needed
Lids totted on? ye: No
Affoa;U'ved, 4q*Mnwn
oonttO pimles
O"Cot iieaafe
Of Dt"fge,' L. Oaf Ott CMUOIS' 00
�"fravW Tmile- Tin%
�-otA
Med fon" t* 1-866-384-7404
To:
Page: 2 of 3 2023-09-07 22:46:43 GMT 19073086608 From: Wes Anderson
.... . .....
4451624
1111 1111 is Is If
on 11 Bill I oil 5 11-10 a IN 8 1 of 0.
'11-101
*varMeW Field MoMmm" Bowl
AnchorageTank
Annual Inspection 907 272-3543
propedyti(iolilpr
i . 1
Ian Rose
A+ Home Services Tech
SO
6 101 Greece Drive, Anchorage AK 99516
(907) 675-6956
AX Site ID N GMMV'Y to 11
AXA37709 OSP1SID40
Pcd
422168
ITu #/VL 4 Olde of Lw irspoew.
RTU132100 05/16/2023
Retrieve (WA Info
Timer setffnW
WU (1$:t MA PH 1 (6-9) 1 DO (2A 1
7 e
�-7
Odor *t 8=440
Typical 'N'1MVw Lj Euthy Lj Mo*
r4-'tYw"'w Oswrw C7, owtmv ED N—Y
O,VMMin-PVU [_Yea rsjN.
Foam in tank E, Yes Sj N,
C44"w control PWIM
lIscitc Amps ill Amps
Aw*ble and v1KW aWms jNOK
Dial tone (tolerristry OW N---' Yes Ot4o
10spectiCkhm Pump System
ftMPO&- Clean
FlIwAid ................... ..
SP40 Box—.
Wits................. .. ....
Funp ......
Biobbe" Filter .... .......... L N, N
61oluber PwV Vault ............ (�' IN
PwArmianna swMer VwM ...... &L NL
Comments; N
r�17 I
Measure Slufte/Scum
ist Compa"mmit
cvffant
Previotts
current
prevkw$
2nd Comparhywwt
current
prevkw
-Current
PrOWMIS
lnspftVCle&n-AdvanTsx, Filter
Odor: IQ Normal Opurlgent
Bl,,mat Excessive Pud%ttom
DoitelF�nor Excassava tMake Vent N
Inspeevel"" Dischatroo Pump System.
Inspect inspect clean
Fifsernk Floots
soos Box LEI P-V C-1 uw
%st Cot&
Inspeauser"Me O"wr system domponents
Inspect Clean Inspect Clean
Disinfodion Equipment Dispersal LatemWOMicos!&
Additional Se rVices Rendered
0 Owwwd textile gwu-? 17-1 Repwed uV item?
Replacedikhed 00w Remo?
Parts Utt ed! w warr"Oty, R = OW-bi. V VWopiata c0l-tk-)
w 5 MOVI WMAW DO-w4won
L.4.4
FinstlSetaty Inspection
N4,isv reinswed
75P.-Ifold reconnected; flush valves, closed JT—'VwWpanaI reactivated
NL- System persormog; Ta'* needs punimq:
i CM for servim j00
M M��
• Municipality of Anchorage
z �Q
On -Site Water and Wastewater Program
(907) 343-7904 5 FI E T Y
��'' RUSH
Certificate of On -Site Systems Approval
Parcel I.D. 020-281-58 Expiration Date: /
1. GENERAL INFORMATION
Complete legal description Potter Highlands Phase 1, Block 1, Lot 6
Location (site address) 6101 Greece Dr.
Current Property owner(s) John Hagmeler Homes LLC. Day phone
Mailing address 2204 Cleveland St. Ste 201 Anchorage, AK 99517
Real Estate Agent Day phone
2. TYPE OF DWELLING:
Fx1 Single Family (w/wo ADU)
❑ Duplex
❑ Multiple Dwellings (Single Family and/or Duplex)
3. NUMBER OF BEDROOMS: 4
4. TYPE OF WATER SUPPLY:
Individual Well
Individual Water Storage
Community Class Well
Public Water System
WaiverNariance request for:,
TYPE OF WASTEWATER DISPOSAL:
F�
Individual
0
❑
Holding Tank
❑
❑
Community
❑
❑
Public Sewer
❑
Received by: 4
COSA to be released
COSA Fee $ '� �! I b� Waiver Fee $
Date of Payment l 02311 Date of Payment
Receipt Number 1�8a 1ol_G1 Receipt Number
COSA# o5C-L5f9 Waiver#
5. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined
in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater
disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that
based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply
and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at
the time of installation.
In conducting an adequacy test, I attempt to provide a thorough, conscientious engineering analysis of the system in accordance with MCA COSA
guidelines and regulations. The reported results describe the performance of the system under the conditions encountered at the time of the test,
and separation distances measured to readily identifiable features. The operational life of all wells and septic systems depend on the local soil
Condition, ground water levels that may fluctuate during the year, and the water usage of the family being served by the system. These conditions
are outside the control of the evaluator of this system. All systems eventually fail and satisfactory test results do not guarantee future
performance of the system, nor do they guarantee that there are no hidden defects or encroachments. Therefore we cannot provideany warranty
for future performance, nor can we estimate remaining life of the system. The content of this report is for the sole benefit of the owner listed
above. - -
Name of Firm Pannone Engineering Services LLC Phone (907) 272-8218
Address P.O. Box 100217, Anchorage Ak. 99510
Engineer's Printed Name Steven R Pannone
Date 10/14/2015
sr:
6. DSD SIGNATURE •
System #1 Approved for bedrooms : Sieve h:'Pa r
System #2 Approved for bedrooms cam'•• CE -8149
Disapproved ��,}1 H?OFES51�.
P
�\\\��0
Conditional approval for bedrooms, with the following stipulations:
By:41 Original Certificate Date: J4 1
ir
Th Mu icipality, of Anchorage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only
upon he representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality
of Anchorage is not responsible for errors or omissions in the professional engineer's work.
7. ATTACHMENTS:
COSA Checklist X Nitrate Advisory
Septic System Advisory Arsenic Advisory
Well Flow Advisory Other
COSA blue sheet v ( -
If more than I septic system is-onthe lot:
COSA Checklist # + of
Structure served by this system
Certificate of On -Site Systems Approval Checklist
Legal Description: Potter Highlands Phase 1, Block 1, Lot 6
A. WELL DATA
Well type Private If A, B, or C provide PWSID #
Date completed 3/10/2015 Sanitary seal (Y/N) Y
Total depth 226 ft. Cased to 111 ft.
FROM WELL LOG
Date of test 3/10/2015
Static water level 121
ft.
Well production 8
9 -
p.m -WATER SAMPLE RESULTS:
Coliform colonies/100 mL Nitrate
1�6 2_mg/L
Arsenic /VD ug/L Date of sample:
10/12/2015
B. SEPTICIHOLDING TANK DATA
Tank Type/Material Orenco/Plastic
Tank size 1,500 gal. Number of Compartments 2
Foundation cleanout (YIN) Y Depression over tank (YIN) N
Date of pumping New Pumper N/A
C. ABSORPTION FIELD DATA
Parcel ID: 020-281-58
Well Log (YIN) Y
Wires properly protected (Y/N) Y
Casing height (above ground) 18+ in.
AT INSPECTION
New
New ft.
New _ g.p.m.
CaRected by:
PES
Date installed 10/8/2015
Cleanouts (Y/N) Y
High water alarm (YIN) Y
Date installed 10/912015 Soil rating (g.p.d./ft2 or fe/bdrm) 4 GPD/SF System type Deep Trench
Length 20 ft. _ Width 3 ft. Gravel below pipe 6 ft.
Total depth 12 ft. Eff. absorption area 240 if Monitoring tube Y Depression over field N
Date of adequacy test New Results (Pass/Fail) PASS For 4 bedrooms
Fluid depth in absorption field before test NeWin. Water added New gal. New depth New in.
Elapsed Time: New min. Final fluid depth New . in. Absorption rate >= 600+ g.p.d.
Any rejuvenation treatment (past 12 mo.) (Y/N &type) NO If yes, give date
D. LIFT STATION
Date installed 10/8/2015
"Pump on" level at -43 in.
Datum Bottom of Tank
E. SEPARATION DISTANCES
WELL ON LOTTO:
Size in gallons 250
"Pump off' level at 40 in.
Cycles tested None
Septic tank/lift station on lot 100+
Absorption field on lot 100+
Public sewer main 75+
Sewer /septic service line 25+
Animal containment areas 50+
SEPTIC/HOLDING TANK ON LOT TO:
Manhole/Access (Y/N) Y
High water alarm level at 45 in.
Meets alarm & circuit requirements? Yes
On adjacent lots 1.t)0+
On adjacent lots 100+
Public sewer manhole/cleanout 100+
Holding tank 100+
Manure/animal excrete storage areas 100+
Building foundation 5+ Property line 5+ Absorption field 5+
Water main 10+ Water service line 10+ Surface water 100+
Wells on adjacent lots 100+
ABSORPTION FIELD ON LOT TO:
Property line 10+ Building foundation 10+
Water Service line 10+
Curtain drain 50+
F. COMMENTS
Surface water 100+
Wells on adjacent lots 1Q0+
G. ENGINEER'S CERTIFICATION
1 certify that l have determined through field inspections and
review of Municipal records that the above systems are in
conformance with MOA COSA guidelines in effect on this date.
Engineers Printed Name Steven R. Pannone
Date
COSA canary sheet_2-6-15.doc
10/14/2015
Water main 10+
Driveway, parking/vehicle storage 110+
PLAT NO. 2013-113
POTTER HIGHLANDS SUBD.,
LOT 62 BLOCK 1
PHASE 1
BUILDING DETAIL
SCALE: 1 "=20'
A5 -13U L T
I HEREBY CERTIFY THAT I HAVE SURVEYED THE
GASTALDI LANA
PROPERTY DEPICTED ABOVE AND THAT NO
ENCROACHMENTS EXIST EXCEPT AS INDICATED.
SURVEYING, LLC
IT IS THE RESPONSIBILITY OF THE OWNER TO
JEFF A. GASTALDI, R.L.S.
DETERMINE THE EXISTENCE OF ANY EASEMENTS,
2000 E. DOWLING RD., SUITE 8
COVENANTS OR RESTRICTIONS WHICH DO NOT
ANCHORAGE, ALASKA 99507
APPEAR ON THE RECORDED SUBDIVISION PLAT.
PHONE 248-5454
UNDER NO CIRCUMSTANCES SHOULD ANY DATA
GRID
DATE
HEREON BE USED FOR CONSTRUCTION OR FOR
SW3638
10/15/2015
ESTABLISHING BOUNDARY OR FENCE LINES.
ANCHORAGE RECORDING DISTRICT, ALASKA
15-04 PHS.;151
F.B. JOB NOTE: NO CORNERS SET THIS DATE
1 "®50'
44
A' C : 49TH••'• *�!
�: ... .tea-,.` ...:.........�I
. Jeffery A. Gastaldi AW
'� •.�• LS -6091 m�°AV
s,
+aA .. a 4*
® JOfessianat"°c�+
e
•®r..+•