Loading...
HomeMy WebLinkAboutALYESKA BASIN #7B Lots 2A & 2B S-11729Alyeska Bcisin7B Lots 2A & 2B 5-11729 FLATTOP TECHNICAL SERVICES TED MOORE, P.E. PH./FAX: (907)345-1355 E-Mail: tgmoore~ci.net CML & ENVIRONMENTAL ENGINEERING * ENERGY CONSERVATION & ANALYSIS 14530 ECHO CANYON ROAD ANCHORAGE, AK 995'16 November 4, 2009 Deb Wockenfuss M.O.A. DSD On-Site Water and Wastewater Program P.O. Box 196650 Anchorage, AK 99519-6650 Dear Ms. Wockenfuss: This is in response to your 10/20/09 comment sheet to Anthony Hoffinan regarding a proposed subdivision of Lot 2, Alyeska Basin, Unit 7B. The proposed Lot 2B will be served by public water and sewer and the suitability of the residual Lot 2A for on-site water and wastewater is unchanged from its suitability at the time of original approval of Lot 2 back in 2004. Nevertheless, my responses to your comments (in blue) are as follows: 1. Ground water monitoring must be conducted during high ground water season in either the fall (October) or spring(May). See attached soils logs for results of additional groundwater monitoring conducted in October. 2. Areas designated for the original and replacement wastewater disposal system sites must be identified and must meet all criteria specified in AMC 15.65 including slope and slope setback requirements for each lot. See site plan for designated 10,000 sq. ft. wastewater disposal area on Lot 2A. Lot 2B will be served by AWWU 3. It appeurs that the wastewater disposal sites may be within 50' of excessive slopes. My field measurements indicated that the designated disposal si~tes are not within 50 feet of excessive slopes. 4. Show all easements. See revised site plan. 5. Provide documentation for water availability to serve water wells. See attached copies of previously submitted well logs documenting water availability in the subdivision area. Please call me at 345-1355 if you have further questions. Sincerely, Ted Moore, P.E. cc: Ralph Brodin 17 LOT 2B LOT 1 LOT 3 ' / / 10,OOO8Q. FT. ,,~ AREA ,, LOT 2, ALYESKA BASIN S/D, UNIT 7B SEPTIC SYSTEM FEASIBILITY ~ITF: PLAN FLATTOP TECHNICAL SERVICES 1 INCH = 100 FEET 14530 ECHO CANYON ROAD DRAWN BY TFM ANCHORAGE, AK 99516 REV. NOV., 2009 NOTE: THIS IS NOT A SURVEYED PLAT. ALL LOCATIONS SHOWN ARE APPROXIMATE. ITEST HOLE FLATTOP TECHNICAL SERVICES 14530 ECHO ST. ANCHORAGE, ALASKA 99516 SOILS LOG -- PERCOLATION TEST LEGAL DESCRIPTION: ' DATE PERFORMED: A.ndl .cl. 2003 PERFORMED FOR: Tom Skillir!g c/o Ra ph Brodin EE/CC DEPTH (f~t) SM Reddish sandy loam SP/GP Clean, black gravelly sand Increasing sand fraction w. depth SLOPE Depth to Groundwater Date NO groundwater 4/9/03 Monitor tube dry 4/16/03 Monitor tube dfi/ _ 10/27/09 ¸LO SiTE PLAN SEE SEPARATE SITE PLAN Date Reading Clock Net Time Percometer Net Drop Time (minutes) Reading (inches) 4/9 5d:latlon presoak 1:28:00 24 #1 1:29:00 I 19 3/8 4 5/8 __ ~- 1:29:45 0.75 17 112 Drv COMMENTS: material should avoid the necessity_ to install an imported sand fleer. PERFORMED BY FLAYFOP TECHN,CAL SERV, CES. I .~..~ ~'~..~.-~ ACCORDANCE WITH ALL STATE AND MUNIO,PAL GUIDELINES iN EFFECT ON THIS DATE. PERCOLATION RATE <<1 (minutes/inch) PERC HOLE DIAMETER TEST RUN BETWEEN 4.0 FT AND 4.5 FT Excellent material for construcSon of on-site wastewatar disposal system. Despite_rapid perc rate, sand contant of native CERTIFY THAT THIS TEST WAS PERFORMED iN DATE: /J /~.,~/~',~ ITEST HOLE# LEGAL DESCRIPTION: DATE PERFORMED: PERFORMED FOR:~ DEPTH (feet) 4-__ B.H, COMMENTS: FLATTOP TECHNICAL SERVICES 14530 ECHO ST. ANCHORAGE, ALASKA 99516 SOILS LOG -- PERCOLATION TEST L~n S/D #8 ApdLg: 2003 Tom Skilling c/o Ralph Brodin EEJCC Pt. SM Reddish sandy loam SP/GP Clean, black gravelly sand Sand similar to test hole #1 Fewer cobbles and beuldem SLOPE 25% SITE PLAN SEE SEPARATE SITE PLAN Depth to Groundwater Date -No groundwater J 4/9/03 Monitor tube dry 4/16/03 tonitor tube dry 10/27/09 Date Reading Clock Net Time Percometer Net Drop __ Time (minutes) Reading (inches) PERCOLATION RATE (minutes/inch) PERC HOLE DIAMETER TEST RUN BETWEEN _ FT AND FT Excellent material for construction of on-site wastewater disposal system, See log of TH~I for perc test. PERFORMED BY FLATI'OP TECHNICAL SERVICES. I ~"-~-~ ~ CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: /l/.,~ ,/~' ~ TEST HOLE FLATTOP TECHNICAL SERVICES 14530 ECHO ST. ANCHORAGE, ALASKA 99516 SOILS LOG -- PERCOLATION TEST LEGAL DESCRIPTION: Lot 3. Alyeska~3_sin S/D #8 DATE PERFORMED: PERFORMED FOR:_ Tom Skilling c/o Ralph Brodin EE/CC _ DEPTH (feet) Pt. 1- GMBrown silty gravel Some boulders Water seep ML Brown Silt Many boulders ML Blueish silt Many boulders Very hard digging SLOPE SiTE PLAN SEE SEPARATE SITE PLAN 11 13- 14 I 17- 18- 19 201 COMMENTS: tLOI ~E Depth to Groundwater Date Seeps ¢,, 3' 4/9/03 Clock ! NetTime / Pemometer ! NetDrop Date Reading Time (minutes) Reading (inches) PERCOLATION RATE~ (minutes/inch) PERC HOLE DIAMETER TEST RUN BETWEEN __ FT AND __ FT Soil unsuitable for construction of on-site wastewater disposal system. Mo monitor tube installed in test hole. PERFORMED BY FLATTOP TECHNICAL SERVICES. I~.z~~ "~,"~-,,~__ CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: ~//! f ~-.~