HomeMy WebLinkAboutCROSS VIEW ESTATES BLK 1 LT 21Cross View
Estates
Block 1
Lot 21
#015-221-52
Permit Number:
Tax Code Number:
Work Type:
On-Site Water & Wastewater System Permit
OSP151068
01522152000
WelISeptic
MUNICIPALITY OF ANCHORAGE
Development Services Department
On-Site Water & Wastewater Program
4700 Elmore Road, PO Box 196650
Anchorage, AK 99519-6650
Telephone: (907) 343-7904
Initial
Permit Effective Dates: April 07, 2015 to April 06, 2016
Design Engineer: ANDERSON ENGINEERING
Subdivision: CROSS VIEW ESTATES
Site Legal Address: CROSS VIEW ESTATES BLK 1 LT 21 G:2737
Owner/Address: COLONY BUILDERS INC
9420 VANGUARD DR #A ANCHORAGE AK 995070000
· Department
Site Mailing Address:
Lot Size in Sq Ft: 50119
Total Bedrooms: 5
This permit is for the construction of:
Y Disposal Field Y SepticTank N Holding Tank ' N Privy Y Private Well N Water Storage
All construction must be in accordance with: 1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Aia~ka Wastewater
Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80).
3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services
Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours).
4. From October 15 to April 15, a subsurface soil aSsorption system under construction during freezing weather must either:
A. Open and Close on the same day.
B. Covered, sealed, and heated to prevent freezing.
IsSued By~--~l~ ~
!
MUNICIPALITY OF ANCHORAGE
Community Development Department
Development Services Division
On-Site Water & Wastewater Program
ON-SITE SEWER/VVELL PERMIT APPLICATION
Phone: 9~-343-7904
Fax: 907;~3-7997
Parcel I.D. 015-221-52
Property owner(s) Colony Builders Day phone
Mailing address 9420 Vanguard Drive #A Anchorage, AK 99507
Site address NHN Heritage Heights Drive Anchorage, AK 99516
Legal description (Sub'd., Block & Lot) Cross View Estates, Block 1, Lot 21
Legal description (Township, Range & Section)
Lot Size 50,119 Sq. Ft. Number of Bedrooms Five (5)
APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING:
([~ all that apply)
Absorption Field [] Initial [] Single Family (SF) []
(w/wo ADD)
Septic Tank [] Upgrade []
Duplex (D) []
Holding Tank [] Renewal []
Multiple Dwellings []
Privy [] (SF and/or D)
Private Well []
Water Storage []
THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR:
Distance:
I certify that the above information is correct. I further certify that this is in accordance with
applicable Municipal Codes.
(Signature of property owner or authorized agent)
Permit/Rush Fees: ~,~-~./~'
Date of Payment:
Receipt Number:
Permit No.
Waiver Fees:
Date of Payment:
Receipt Number:
Waiver No.
Permit App_9-1-12.doc
April 6, 2015
Municipality of Anchorage
Development Services Department
On-Site Water and Wastewater program
4700 South Bragaw Street
Anchorage, AK 99519-6650
Su~e~:
Lot 21, Block 1, Cross View Estates Subdivision
Septic System Design and Permit Application
Impacts to Adjacent Properties
Dear Onsite Services Engineer:
The owner of Lot 21, Block 1, Cross View Estates Subdivision intends to construct a
new five-bedroom home on the lot. We are therefore requesting a permit be issued for
the construction of a new well and septic system to accommodate the home. The
attached Site Plan and backup documentation identify the location and configuration of
the proposed well and septic system along with the alternate site. Also identified on the
plans are the existing wells in the area and septic systems on surrounding lots. No
conflicts exist between the proposed septic system and well or septic systems and wells
on adjacent lots. Drainage arrows are shown on the site plan showing the grade and
direction of flow on the lot. The drainage pattern will not be changed as a result of this
project.
The test hole placed on the lot in the area of the absorption trenches and alternate site
indicate silty sand with gravel (SM/GM). The percolation rate of the soil was
determined to be 48 minutes per inch. No groundwater was found during the
placement of the test holes and none was noted during the monitoring period. An
application rate of .45 gallons per day per square foot was used in the design of the
absorption system. We are proposing to place a new 1,500-gallon septic tank and 2-
54' long by 3' wide by 8' effective depth absorption trenches to treat and dispose of the
effluent generated in the house. The elevation of the distribution line in the absorption
trench will be'4' below the surface and the total depth will be 12'. A flow splitter valve
will be placed to insure even flow to each trench. A minimum of 3' of fill or 2" of
insulation and 2' of fill will be placed over the absorption trench and 4' over the septic
tank.
Lot 21, Block 1, Cross pOint Estates Subdivision
April 6, 2015
Page Two
The ground surface on the lot in the area of the septic system slopes to the nodhwest
at a shallow grade with some cross sloping from the east. The new trenches will be
constructed parallel with the contours of the slope as much as possible in conformance
with Municipal requirements. The new septic system will be constructed a minimum of
100' from all wells and any surface water and 10' the proposed and existing water
services in the area.
If the system is constructed in accordance with our design the following statements
apply:
The system, if constructed as designed, will have no adverse impact on the wells
in the area or those to be constructed in the future.
The system, if constructed as designed, will have no adverse impact on existing
septic systems in the area or those to be constructed in the future.
The system, if constructed as designed, will have no adverse impact on reserve
space, either surface or subsurface, on any lots located in the area.
The system, if constructed as designed, will have no adverse impact on drainage
patterns in the area. The current drainage pattern will be maintained.
SincerelY,
Michael E. Anderson, P.E.
Attachments
~ ~;'"
- ~ 49th
LOT 21, BLOCK 5
SKY RANCH NO. 1
LOT '18, BLOCK 1 /r___"_'_~_~__7____
I Vacant
' ] --~-'"
LOT 16, BLOC~~ LOT 14, BLOCK 2/ ~LOT 13, BLOCK~
===================================== .............................................................. (5_~_~2~_~_( ....
[~~:~' "~" "'~ AREA HAP
PLAT NO. 2006-171
CROSS VIEW
ESTATES SUB.
LOT 21, BLOCK
50,119 S.F.
20' X 40' GAS ESMT.
'1
Proposed
Well ®
N 89'47'40"E 163.06'
10' T. & E. ESMT.
5' WALKWAY ESMT.
ALTERNATE SITE
Advontex Treotment System
with 40' Long x .3' Wide x
Effective Depth Absorption
Trench, (1 GPD/SF)
2-54' Long x 3' Wde M~F~V
x 8' Effective Depth CO'~
Absorption Trenches
SV 1,500 Gollon
Z
N 89'27'47"E
20' STORM DRA~ ESMT.
165.~7'
HERITAGE HEIGHTS DRIVE
SITE PLAN
SCALE i' = 40'
LOT 21, BLOCK 1, CROSS VIEW ESTATES SUBDIVISION
DESIGN FACTORS: SYSTEM REQUIREMENTS:
Five Bedroom Home Deep Trench System
Parc. Rate: 30-60 Min./inch 1,500 Gallon Septic Tank
Application Rate: .45 GPD/SF 8' Drainfield Rock
5 Bedrooms X 150 GPD/.45 GPD/SF (Application Rate) = 1,666.7 SF Absorption Area
1,666.7 SF/16 SF/LF = 104.17 LF Trench Length
THEREFORE: Construct 2-54' Long x 3' Wide x 8' Effective Depth Absorption Trenches at the
Location Shown. Flow Line Elevation in the Trenches to be 4' Betow Original Ground. Total Depth
to Be 12' Below Existing Ground. Provide 4' of Cover Over Septic Tank and a Minimum of 3'
Cover Over Absorpiton Trenches. Maintain 100' Separatibn from Wells in the Area. Place Flow
Splitter Valve to Insure Even Flow to Each Trench.
Natural
Backf Geotextile
-- Fabric
~ O 4" Perforated
I~VC (Holes Down)
Drainfield .Rock
TYPICAL DEEp TRENCH SECTION
(NO SCALE) Awe ~' ......... '"?"~'~-
NOTE: Grade Area Over Trench to Drain y. ·
Minimum 6: Separation From Bedrock. ~'~-"4"~'n'"'y/'"~.":'~.¢"'";~'l
Minimum 4 S,eparation From Groundwater. ~.~
Minimum 100 Separation From Wells in the Area. &.~\ M~C~ELE.^NDERSO"
Minimum 100' Separation From Surface Water or Streams. ",~o...
MUNICIPALITY OF ANCHORAGE
DEVELOPMENT SERVICES DEPARTMENT
Z+700 BRAGAW STREET ANCHORAGE, AK @9519-6650
SOILS LOG - PERCOLATION TEST
DEPTH
1
2
3
4--
5--
6
7
8
9
11
19
20.
PERFORMED FOR:
DATE: 5/24/15
PARCEL ID#:
LEGAL DESCRIPTION: LOT 21, BLOCK I, CROSS VIEW ESTATES SUBDIVISION
L. BETTS
C..OLONY BUILDERS
PROIECT No.:
TECHNICIAN:
I TEST HOLE
OB/OG
SILTY SAND
WITH GRAVEL
SM/GM
WAS GROUND WATER ENCOUNTERED?
IF YES ~ WHAT DEl'THo
DEPTH OF WATER AFTER MONITORING: NONE
DATE OF MONITORING:
;LOPE
No
BOH @ 18'
SITE PLAN
SEE SITE PLAN
DEPTH TO
DATE READINO GROSS TIHE NET TildE WATER NET DROP
(MINUTES) (MINUTES) (INCHES) (INCHES)
TEST HOLE PRESOAKED PRIOR TO TESTING:
3/26 1 2:14 1.25"
2 2:34 30 2.00" .75"
3 2:35 1.375"
4 3:05 30 2.00" .625"
5 3:06 1.25"
6 3:36 30 1.875" .625"
PERCOLATION RATE:48 (MIN/INCH) PERC. HOLE DIA. 6" _(INCHES)
TEST RUN BETWEEN[ 4.5 FT. and. 5.5 FT.
COMMENTS: TEST HOLE PRE SOAKED PRIOR TO TEST.
TEST PERFORMED BY ANDERSON ENGINEERING. I, MICHAEL E, ANDERSON CERTIFY THAT
THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPLE GUIDELINES IN EFFECT ON THIS
DATE: 4/6115
4700
DEPTH
1
2
3
4
5
6
7
8
9
11
20
MUNICIPALITY OF ANCHORAGE
DEVELOPMENT SERVICES DEPARTMENT
BRAGAW STREET ANCHORAGE, AK 99519-6650
SOILS LOG - PERCOLATION TEST
LEGAL DESCRIPTION: LOT 21, BLOCK I, CROSS VIEW ESTATES SUBDIVISION
PERFORMED FOR:
DATE: 5/24/15
PARCEL ID#:
COLONY BtJILDERS
?ROJECT No.:
TECHNICIAN:
OB/OG
WAS GROUND WATER ENCOUNTERED?
IF YES @ WHAT DEPTHV
DEPTH OF WATER AFTER MONITORING:
SILTY SAND
WITH GRAVEL
SM/GM
L. BETTS
i~% HICHC, CL E. ANDERSD
,,,o. cc-,,,,, ....:¢,,"
Professional Engineers Stamp:
BOH @ 16'
SLOPE
No
SITE PLAN
SEE SITE PLAN
DATE OF MONITORING: 4/6/15 ~ ~
DEPTH TO
DATE READING ;ROSS TIME NET TIME WATER ',lET DROP
(idlNUTES) (MINUTES) (INCHES) (INCHES)
TEST HOLE PRESOAKED PRIOR TO TESTING:
3/26 1 2:25 2.375"
2 2:55 30 3.375" 1.00"
3 2:56 2.50"
4 3:26 30 3.50" 1.00"
5 3:27 2.25"
6 3:57 30 3.25" 1.00"
PERCOLATION RATE: 30 .(NIH/INCH) PERC. HOLE DIA. 6" .(INCHES)
TEST RUN BETWEENi 4.5 FT. and 5.5 FT.
COMMENTS: TEST HOLE PRE SOAKED PRIOR TO TEST.
TEST PERFORMED BY ANDERSON ENGINEERING. I, MICHAEL E. ANDERSON CERTIFY THAT
THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPLE GUIDELINES IN EFFECT ON THIS
DATE: 416115