Inspection Report_1-1-12.doc -
Municipality of Anchorage
Community Development Department Page 1 of 3
On -Site Water and Wastewater Program
4700 Elmore St. • P.O. Box 196650 Anchorage, AK 99519-6650 • http://www.muni.org/onsite • (907) 343-7904
ON-SITE
WASTEWATER INSPECTION REPORT
Permit Number: OSP151055
PID Number: 051-312-14 ❑✓ New ❑ Upgrade
Name:
ABSORPTION FIELD
Troy Davis Homes
❑ Deep Trench ❑✓ Shallow Trench ❑ Bed ❑ Mound
Address
165 E. Parks Hwy, Suite 200 Wasilla, AK 99654
❑ Other
Phone
Number of Bedrooms
Soil Rating
Total depth from original grade
357-9394
4
.8 GPD/SF
4.6-4.8 Ft.
LEGAL DESCRIPTION
Depth to pipe invert from original grade
2.6-2.8 Ft.
I Gravel depth beneath pipe
2.OFt.
Subdivision
Block Lot
122
Fill added above original grade
1.5-3 FL
Gravel length
106 Ft.
Township Range Section
15N
2W 25
Gravel width
5Ft.
Beds: Number of Lines
Distance between lines
Ft.
SEPARATION DISTANCES
TO
Septic
Absorption
Holding
Sewer
Total absorption area
Number of trenches
Dist. between trenches
From
Tank
Field
Lift Station
Tank
Line
757 Fel
Two
>10FL
Well
>100'
>100'
>100'
>75'
>25'
TANK ❑ Septic ❑ S.T.E.P. ❑ Holding ❑ Other
Manufacturer
Anchorage Tank
Capacity
1,25OGal.
Surface water
>100'
>100'
N/A
NIA
Material
Steel
Number of compartments
Two
Lot Line
>5'
>10'
N/A
N/A
NA
Foundation
>5'
>10'
N/A
NIA
LIFT STATION
Manufacturer
Capacity
Gal.
Curtain Drain
NoneNoted
Pump on level at
Pump off level at
High water alarm at
Remarks
in.
in.
in.
Pump make and model
Electrical Inspections performed by
PIPE MATERIAL House to tank D3034 Tank to D3034
drainfield
Installer
Northern Excavation
Drainneld F810 CO/MT D3034
Inspector W Roberts
BENCH MARK (Assumed elevation) 100.Oft
Inspection
1' 4/20/15
4/21/15
Location and description
dates:
2m
Back Deck SE Corner.
3" 4/22/15
4'"
COMMUNITY DEVELOPMENT DEPARTMENT APPROVAL
E:gneirtilmp
OF A
Conditional Approval:
Date`P�
49-H*•:*�i
�.... .... ... .... ...0
j.....
............................. e
>! rte„• MICHAEL E. ANDERSON 00
AV
CE - 4381
/D is
`4v'
��It,
Approved
Date /S
is`
Inspection Report_1-1-12.doc -
On-Site Water & Wastewater System Permit
MUNICIPALITY OF ANCHORAGE
Development Services Department
On-Site Water & Wastewater Program
4700 Elmore Road, PO Box 196650
Anchorage, AK 99519-6650
Telephone: (907) 343-7904
Permit Number: OSP151055
Tax Code Number: 05131214000
Work Type: WelISeptic Initial
Permit Effective Dates: April 08, 2015 to April 07, 2016
Design Engineer: ANDERSON ENGINEERING
Subdivision: T15N R2W SEC 25
Site Legal Address: T15N R2W SEC 25 LT 122 G:0653
Owner/Address: DICKSON KELLY A 2008 TRUST
DICKSON KELLY A / TRUSTEE 40948 VISTA VALLE PALMDALE CA 935511195
Site Mailing Address: 18024 ALMDALE AVE, Eagle River Lot Size in Sq Ft: 108900
Total Bedrooms: 4
This permit is for the construction of:
Y Disposal Field Y Septic Tank N Holding Tank N Privy Y Private Well N Water Storage
All construction must be in accordance with: 1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater
Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80).
3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services
Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either:
A. Open and Close on the same day.
B. Covered, sealed, and heated to prevent freezing.
Received By:
Issued By:
MUNICIPALITY OF ANCHORAGE
Community Development Department
Development Services Division
On-Site Water & Wastewater Program
Phone: 907-343-7904
Fax: 907-343-7997
ON-SITE SEWERNVELL PERMIT APPLICATION
Pamel I.D. 051-312-14
Property owner(s) Troy Davis Homes Day phone 310-2501
Mailing address 165 E. Parks Highway #200 Wasilla, AK 99654
Site address 18024 Almdale Avenue Eagle River, AK 99577
Legal description (Sub'd., Block & Lot)
Legal description (TownshiP, Range & Section) T15N R2W Section 25 Lot 122
Lot Size 108,900 Sq. Ft. Number of Bedrooms Four
APPLICATION IS FOR:
(~:=1 all that apply)
Absorption Field []
Septic Tank []
Holding Tank []
Privy []
Private Well []
Water Storage []
APPLICATION IS AN:
TYPE OF DWELLING:
initial [] Single Family (SF)
(w/wo ADU)
Upgrade []
Duplex (D)
Renewal [] Multiple Dwellings
(SF and/or D)
THIS APPLICATION INCLUDES A VARIANCE I WAIVER REQUEST FOR:
Dis tance:
I certify that the above information is correct. I further certify that this is in accordance with
applicable Municipal Codes.
(Signature of property owner or authorized agent)
Permit/Rush Fees:
Date of Payment:
Receipt U umber:
Permit No.
Waiver Fees:
Date of Payment:
Receipt Number:
Waiver No.
Permit App_.'- :.
I ANDERSON ENG INEERI NG Ij
/ P;O: BOX 240773
/ ANCHORAGEi AK 99524
~ 522.7773 677:7766 (FAX)
March 23, 2015
Municipality of Anchorage
Development Services Department
On-Site Water and Wastewater Program
4700 South Bragaw Street
Anchorage, AK 99519-6650
Subject:
BLM Lot 122, Section 25, T15N, R2W
Septic System Design and Permit Application
Impacts to Adjacent Properties
Dear Onsite Services Engineer:
The owner of BLM Lot 122 intends to construct a new four-bedroom home on the lot.
We are therefore requesting a permit be issued for the construction of a new well and
septic system to accommodate the home. The attached Site Plan and backup
documentation identify the location and configuration of the proposed septic system
along with the alternate site. No existing wells are closer than 100' from the proposed
septic system. Drainage arrows and ground surface contours are shown on the site
plan showing the grade and direction of flow on the lot. The drainage pattern will not be
changed as a result of this project.
The test holes placed on the tract in the area of the absorption trench and alternate site
indicated silty sand with gravel (SM) material. The percolation rate of the soil was
determined to be 11-14 minutes per inch. Groundwater was found at 11' beneath the
surface during the placement of the test holes and was recently found at slightly more
than 10' during the monitoring period. An application rate of .8 gallons per day per
square foot was used in the design of the absorption system. We are proposing to
place a new 1,250-gallon septic tank and 2-53' long by 5' wide by 2' effective depth
absorption trench to treat and dispose of the effluent generated in the house. The
elevation of the distribution line in the absorption trench will be 3' below the surface and
the total depth will be 5'. A minimum of 3' of fill or 2" of insulation and 2' of fill will be
placed over the absorption trench and 4' over the septic tank.
The ground surface on the lot in the area of the absorption trench slopes from the east
to the west at shallow slopes. The new trench will be constructed parallel with the
contours of the slope as much as possible in conformance with Municipal requirements.
The new septic system will be constructed a minimum of 100' from all wells and any
BLM Lot 122, Section 25, TI5N, R2W
March 23, 2015
Page Two
surface water and 10' from the proposed and existing water services in the area.
If the system is constructed in accordance with our design the fOllOwing statements
apply:
[.
The system, if constructed as designed, will have no adverse impact on the wells
in the area or those to be constructed in the future.
The system, if constructed as designed, will have no adverse impact on existing
septic systems in the area or those to be constructed in the future.
The system, if constructed as designed, will have no adverse impact on reserve
space, either surface or subsurface, on any lots located in the area.
The system, if constructed as designed, will have no adverse impact on drainage
patterns in the area. The current drainage pattern will be maintained.
Sincerely,
Michael E. Anderson, P.E.
Attachments
N89'49'40"W 529.01
NOTE:
NO Areos of Excessive Slope ore
· · . 131
W,th,n 50 Oownslope or Su~oce LEGEND
Woter Within 100' of Any PO~ of the MT - Monier Tube
~. - T.~ .o,~ 132
co - cme*n Out
t:~:~~ S I T E P L A N 2C0- Double 6leon Out
-- - -
4700
DEPTH
(~et)
1
2
3
4--
5
6
7
8
9
11
20-
MUNICIPALITY OF ANCHORAGE
DEVELOPMENT SERVICES DEPARTMENT
BRAGAW STREET ANCHORAGE, AK 99519-6650
SOILS LOG - PERCOLATION TEST ]
LEGAL DESCRIPTION: BLM LOT 122, TI5N, R2W, SECTION 25
PERFORMED FOR:
DATE: 2/27/15
PARCEL ID#:
OB/OG
SILTY SAND
WITH GRAVEL
SH
TROY DAVIS HOMES. INC.
PROJECT No.:
TECHNICIAN:
[TEST HOLE1 ]
WAS GROUND WATER ENCOUNTERED? __
IF YES ~ WHAT DEPTH'~__
DEPTH OF WATER AFTER MONITORING:
BOH @ 16'
L. BETTS
SLOPE
YES
SITE PLAN
SEE SITE PLAN
DATE OF MONITORING: 5/21;r5 ~ ~
DEPTH TO
DATE READING GROSS TildE NET TINE WATER NET DROF
(MINUTES) (MINUTES) (INCHES) (INCHES)
TEST HOLE PRESOAKED PRIOR TO TESTING:
2/28 1 I0:08 1.50"
2 10:38 30 3.75" 2.25"
3 10:39 125"
4 11:09 30 3.50" 2.25"
5 11:10 1.38"
6 11:40 30 3.63" 2.25"
PERCOLATION RATE:13.3 (M1N/INCH) PERC. HOLE DIA. 6" J~INCHES)
TEST RUN BETWEEN: 4.0 FT. and 5.0 .FT.
COMMENTS: TEST HOLE PRE SOAKED PRIOR TO TEST,
TEST PERFORMED BY ANDERSON ENGINEERING. I, MICHAEL E. ANDERSON CERTIFY THAT
THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNIC1PLE GUIDELINES IN EFFECT ON THIS
DATE 5/22/15
&700
DEPTH
(feet)
1
2
3
4
5
6
7
8
9
11
MUNICIPALITY OF ANCHORAGE
DEVELOPMENT SERVICES DEPARTMENT
BRAGAW STREET ANCHORAGE, AK 99519-6650
SOILS LOG - PERCOLATION TEST
LEGAL DESCRIPTION:
PERFORMED FOR:
DATE: 2/£7/15
PARCEL ID#:
OB/OG
SILTY SAND
WITH GRAVEL
SH
BOH @ 16'
BLM LOT 122, TISN, R2W, SECTION 25
TROY DAVIS HONES, INC.
PROJECT No.:
TECHNICIAN:
WAS GROUND WATER ENCOUNTERED?
IF YES ~ WHAT DEPTH?
DEPTH OF WATER AFTER MONITORING:
L. BETTS
SLOPE
YES
SITE PLAN
SEE SITE PLAN
2% J
DEPTH TO
DATE READING 3ROSS TIME NET TIME WATER NET DROP
(MINUTES) (MINUTES) (INCHES) (INCHES)
TEST HOLE PRESOAKED PRIOR TO TESTING:
2/28 1 12:04 0.50"
2 12:34 30 3.25" 2.75"
3 12:35 0.87"
4 1:05 30 3.50" 2.63"
5 1:06 0.75"
6 1:36 30 3.38" 2.63"
PERCOLATION RATE:I 1.4 (MIN/INCH) PERC. HOLE DIA. 6" .(INOIES)
TEST RUN BETWEEN:. 4.0 FT. and 5.0 FT.
COMMENTS: TEST HOLE PRE SOAKED PRIOR TO TEST.
TEST PERFORMED BY ANDERSON ENGINEERING. I, MICHAEL E. ANDERSON CERTIFY THAT
THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPLE GUIDELINES IN EFFECT ON THIS
DATE: 5122/IS
T15N R2W SECTION 25 BLM LOT 122
DESIGN FACTORS:
Four Bedroom Home
Perc. Rate: 6-15 Min./Inch
Application Rate: .8 GPD/SF
SYSTEM REQUIREMENTS:
5' Wide Trench System
1.250 Gallon Septic Tank
2' Drainfield Rock
4 Bedrooms * 150 GPD/Bedroo.m. = 600SF Abso. rpti. o~n_A, r_ea_.. .
600 SF/.8 GPDISFt5 SF (Width) .7 (Red. Factor)= lub Lb/rencn Length
THEREFORE: Construct 2-53' Long x 5' Wide x 2' Effective Depth Absorption Trenches.
3' Below Existing Ground. Provide 3' Cover Over Absorption Trenches and 4' Cover Over
Septic Tank. Plabe Flow Splitter Valve to Insure Even Flow to Each Trench.
,1
/ Geotextile Fabric
~ 4" Per[orated
PVC (Holes Down)
Drainfield Rock
TYPICAL 5' WIDE TRENCH SECTION
(.OSCALE) . ...........
_--' %"'
NOTE' Grade Area Over Trench to Dra~n Away. ~ ~
Mimmum 6. Separation From Bedrock. ~...~-...~.......8......~..~.,.-..~
Minimum 4 Separation From Groundwater. ~ ~.
Minimum 100' Separation From Private Wells in the Area. ~'~'";;;~.~;~;;~;'"?'~
Minimum 100' Separation From Sudace Water or Streams. ~.. No.
'*;~*...,~. 7- ~....*'*~