HomeMy WebLinkAboutFIRE LAKE LT E-1#051-333-46 r��f'-1 �16•",�f.. Municipality of Anchorage , On -Site Water and Wastewater Program ° (907) 343-7904 ae t Jf 3 ON-SITE WASTEWATER INSPECTION REPORT L Permit Number: OSP151096 PID Number: 051-333-46 Dwelling: 0 Single Family (SF) ® Duplex (D) ❑ Multiple (SF and/or D) Project: ❑ New X Upgrade Name: Randall Liska Living Trust ABSORPTION FIELD ❑ Deep Trench El Shallow Trench El Bed EJ Mound Address 14645 Don Circle Eagle River, AK 99557 ❑■ Other Phone Number of Bedrooms Soil Rating depth from original grade 4 GPD/SF JTotal Ft. LEGAL DESCRIPTION Depth to pipe invert from original grade Ft. Gravel depth beneath pipe Ft. Subdivision Block Lot Fire Lake E-1 Fill added above original grade Ft. Gravel length Ft. Township Range Section Gravel width Ft. Beds: Number of Lines Distance between lines Ft. SEPARATION DISTANCES To Septic Absorption Lift Station Holding Sewer Total absorption area Number of trenches Dist. between trenches From Tank Field Tank Line FtZ Ft. Well >100' NA NA NA NA TANK ❑■ Septic ❑ S.T.E.P. ❑ Holding ❑ Other Manufacturer Anchorage Tank Capacity 1,250 Gal. Surface Water >100' NA NA NA Material Steel Number of compartments Two Lot Line >5' NA NA NA NA Foundation >5' NA NA NA LIFT STATION Manufacturer Capacity Curtain Drain None Noted Gal. RemarksOnly the Septic Tank Replaced Under Pump on level at in. Pump off level at in. High water alarm at in. This Permit. Exisiting Septic Tank Decommissioned in Accordance with Pump make and model Electrical Inspections performed by Municipal Code. PIPE MATERIAL House to tank D3034 Tank drainfield D3034 Installer Stuart Gilbert Drainfield CO/MT p 034 Inspector MEA BENCH MARK (Assumed elevation) 100.0 ft Inspection15' 5/22/15 5/22/15 Location and description es: 2nd Porch Slab. s'" 4'h COMMUNITY DEVELOPMENT DEPARTMENT APPROVAL ng�e4►r� EOF Conditional Approval: Date ��°'• . ......... 0� MICHAEL E. ANDERSON . A 0 % CE - 4381 .� a. AW Approved Date %% 3 v���'aFESS1 1'�Q���li�� lattr� ems' _20/ Inspection Report_9-1-12.doc cD rn O Lo co :,E 40.0 � la��� O 5 45 z'` .,.; � aL: \ ` Q E M ; Lj 4- E 0 \\`\ in iV c Q . 4-' M. ' w � Qi t0 m ID c .p U �O \ a N M g N J04 c r- 0) V) IO .g Ea; U rno rna� ~ N d o j v L0 ��� z0 w c o U) w tf? o G, p � CU O N _ UJ 0) •--i O -Op N x.1.1 aim. O N d CA U WQ I v mo O o CD U r U CT) ry 0 UJ p/ J C c 00a O T O / w0 Z W Z U // w ioo W C N N0 u 75;U <C //�- ¢ N Vi m 0-0 v UJ f $ 0 N D wow r' O i C i✓ O i W LLJN i' .W d' O 04 LL - 0 d- 00 z 0 n� c > 3z a°> > W .n c :3 o > L D o0p o c c OL) a�° °'o U- S 00°00'00"E 159.47' z M 90 W ' W -0=00 I c) L, O 0 310810 NOG z C) n Municipality of Anchorage DEVEOPMENT SERVICES DEPARTMENT 4700 Elmore Road Anchorage, AK. 99519-6655 - 343-7904 On -Site Wastewater Disposal System or Well Inspection Report Permit Number: OSP151096 4.9 2CO �101.2 � 2CO 1,250 Gallon Septic Tank 7 Tank Only Replaced Under This Permit. Existing Tank Decommissioned in Accordance with Municipal Code. FIRE LAKE SUBDIVISION LOT E-1 -PROPLE • No Scale Page 3 of 3 PID No. 051-333-46 49th ` e .......................................- ` MICHAEL E. ANDERSON �'. No, CE -4361 �% Permit Number: OSP151096 Tax Code Number: 05133346000 Work Type: SepticTank Permit Effective Dates: April 28, 2015 On-Site Water and/or Wastewater System Permit MUNICIPALITY OF ANCHORAGE Development Services Department On-Site Water & Wastewater Program 4700 Elmore Road, PO Box 196650 Anchorage, AK 99519-6650 Telephone: (907) 343-7904 Upgrade to April 27, 2016 Design Engineer: ANDERSON ENGINEERING Subdivision: FIRE LAKE Site LegalAddress: FIRE LAKE LT E-1 G:0554 Owner/Address: LISKA RANDALL J LIVING TRUST LISKA RANDALL J / TRUSTEE 14645 DON CIRCLE EAGLE RIVER AK 995779205 Site Mailing Address: 14645 DON CIR, Eagle River Lot Size in Sq Ft: 42979 Total Bedrooms: 4 Department This permit is for the construction of: N Disposal Field Y Septic Tank N Holding Tank N Privy N Private Well N Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80). 3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343~7904 (24 hours). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either: A. Open and Close on the same day. B. Covered, sealed, and heated to prevent freezing. Date: Date: MUNICIPALITY OF ANCHORAGE Community Development Depadment Phone: 907-343-7904 Development Services Division Fax: 9~ On-Site Water & Wastewater Program ON-SITE SEWER/VVELL PERMIT APPLICATION /,--7/~'~'~ Parcel I D 051-333-46 · .___ ___,_=_, _.. Property owner(s) Randall J. L~ska L~wng Trust Day phone Mailing address 14645 Don Circle Eagle River, AK 99577 Site address Same Legal description (Sub'd., Block & Lot) Fire Lake, Lot E-1 Legal description (Township, Range & Section) Lot Size 42,979 Sq. Ft. Number of Bedrooms Four APPLICATION IS FOR: (~;~ all that apply) Absorption Field [] Septic Tank [] Holding Tank [] Privy [] Private Well [] Water Storage [] APPLICATION IS AN: TYPE OF DWELLING: Initial [] Single Family (SF) [] (w/wo ADU) Upgrade [] Duplex (D) [] Renewal [] Multiple Dwellings [] (SF and/or D) THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR: Distance; I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit/Rush Fees: Date of Payment: Receipt Number: Permit No. Waiver Fees: Date of Payment: Receipt Number: Waiver No. Penmit App_;- ;. :£..;c ~ AN DE RSON ENGIN E ERING P~O, BOX 240773 ANCHORAGE, AK 99524 522-7773 522-6779 (FAX) April 28, 2015 Municipality of Anchorage Development Services Department On-Site Water and Wastewater Program 4700 South Bragaw Street Anchorage, AK 99519-6650 Su~e~: Lot E-l, Fire Lake Subdivision Septic System Design and Permit Application Impacts to Adjacent Properties Dear Onsite Services Engineer: The septic tank on Lot E-l, Fire Lake Subdivision has failed and must be replaced. We are proposing to replace the tank with a new 1,250 gallon septic tank to serve the four- bedroom duplex on the lot. We are therefore requesting a permit be issued for the construction of a new septic tank. The attached Site Plan and backup documentation identify the location and configuration of the existing septic system and the location of the new tank. Also identified on the plans is the existing well on the lot. The subdivision is served by a community water system. The existing tank and lift station on the lot will disposed in accordance with Municipal Code. The drainage patterns on the property will be maintained after construction. The ground surface on the lot slopes to the southeast at a 3% grade in the area of the new tank. The tank will be placed in the same location as the existing tank at nearly the same elevation. It will then be tied in to the existing service line. If the tank is constructed in accordance with our design the following statements apply: The tank, if constructed as designed, will have no adverse impact on the wells in the area or those to be constructed in the future. The tank, if constructed as designed, will have no adverse impact on existing septic systems in the area or those to be constructed in the future. The tank, if constructed as designed, will have no adverse impact on reserve space, either surface or subsurface, on any lots located in the area. Lot E-I, Fire Lake April 28, 2015 Page 2 of 2 4. The tank, if constructed as designed, will have no adverse impact on drainage patterns in the area. The current drainage pattern will be maintained. Sincerely, Michael E. Anderson, P.E. Attachments Z / / / E S O0'O0'O0"e 159.47' Z 390~10 NOO