Loading...
HomeMy WebLinkAboutSHANGRI-LA ESTATES EAST BLK 4 LT 8Block 4 Lot 8 #020-043-78 Permit Number: Tax Code Number: Work Type: On-Site Water & Wastewater System Permit OSP151056 02004378000 WellSeptic MUNICIPALITY OF ANCHORAGE Development Services Department On-Site Water & Wastewater Program 4700 Elmore Road, PO Box 196650 Anchorage, AK 99519-6650 Telephone: (907) 343-7904 Initial Permit Effective Dates: April 28, 2015 to April 27, 2016 Design Engineer: ANDERSON ENGINEERING Subdivision: SHANGRI-LA ESTATES EAST Site LegalAddress: SHANGRI-LA ESTATES EAST BLK 4 LT 8 G:3239 Owner/Address: ANCHORAGE DEVELOPMENT & CONSTRUCTION LLC 9441 ABBOTT LOOP ROAD ANCHORAGE AK 995074221 Site Mailing Address: 16357 MOUNTAIN BREEZE DR, Anchorage Lot Size in Sq Ft: 40000 Total Bedrooms: 4 This permit is for the construction of: Y Disposal Field Y SepticTank N Holding Tank N Privy Y Private Well N Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80). 3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either: A. Open and Close on the same day. B. Covered, sealed, and heated to prevent freezing MUNICIPALITY OF ANCHORAGE Community Development Department Development Services Division On-Site Water & Wastewater Program Phone: 907-343-7904 Fax: 907-343-7997 ON-SITE SEWERNVELL PERMIT APPLICATION Parcel I.D. 020-043-78 Property owner(s) Anchorage Development & Construction LLC Day phone Mailing address 9441 Abbot Loop Road Anchorage, AK 99507 Site address Mountain Breeze Drive Anchorage, AK 99516 Legal description (Sub'd., Block & Lot) Shangri-La East, Block 4, Lot 8 Legal description (Township, Range & Section) '~¢N'4'"'* Lot Size 40,000 Sq. Ft. Number of Bedrooms Four (4) APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: ([] all that apply) Absorption Field [] Initial [] Single Family (SF) [] (w/wo ADU) Septic Tank [] Upgrade [] Duplex (D) [] Holding Tank [] Renewal [] Multiple Dwellings [] Privy [] (SF and/or D) Pdvate Well [] Water Storage [] THIS APPLICATION INCLUDES A VARIANCE I WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I fudher certify that this is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit/Rush Fees: ~c~ )¢ ~'~'- ~'~g~//-- Waiver Fees: Date of Payment: -~/,;~///~"' C~ Date of Payment: Receipt Number: (~Q'~-'~ Receipt Number: Permit No. CY-D~/~"',/O~--~ Waiver No. ANDERSON ENGINEERING P,O: BOX 240773 522'77731 677-7766 (FAX) March 23, 2015 Municipality of Anchorage Development Services Department On-Site Water and Wastewater Program 4700 South Bragaw Street Anchorage, AK 99519-6650 Su~ect: Lot 8, Block 4, Shangri La Estates East Subdivision Septic System Design and Permit Application Impacts to Adjacent Properties Dear Onsite Services Engineer: The owner of Lot 8, Block 4, Shangri La Estates East Subdivision intends to construct a new four-bedroom home on the lot. We are therefore requesting a permit be issued for the construction of a new well and septic system to accommodate the home. The attached Site Plan and backup documentation identify the location and configuration of the proposed well and septic system along with the alternate site. No conflicts exist between the proposed septic system and well or septic systems on adjacent lots. Drainage arrows are shown on the site plan showing the grade and direction of flow on the lot. The drainage pattern will not be changed as a result of this project. The test holes placed on the lot in the area of the absorption trench and alternate site indicate silty gravel with sand (GM) in the zone specified for the absorption trench. The pemolation rate of the soil was determined to be less than 1minute per inch. No groundwater was found during the placement of the test hole and none was noted during the monitoring period. Plat notes require the use of nitrate reducing septic systems on the lot. We have therefore specified an Advantex Treatment System to accommodate four bedrooms. An application rate of 5.0 gallons per day per square foot was used in the design of the absorption system. We are proposing to place a new 1,500 gallon Advantex Tank and AX-20 Pod and a 25' long by 5' wide by .5' effective depth absorption trench to treat and dispose of the effluent generated in the house. A minimum of 2' of filter sand will be placed beneath the drainfield rock to slow the percolation of the septic effluent. The elevation of the distribution line in the absorption trench will be 3.5' below the surface and the total depth will be 4' plus 2' for the filter sand. A minimum of 3' of fill or 2" of insulation and 2' of fill will be placed over the absorption trench and 4' over the septic tank. The surface of the lot will allow gravity flow from the pod to the absorption trench so an add on lift station is not required. Lot 8, Block 4, Shangri La East Subdivision March 23, 2015 Page Two The ground surface on the lot in the area of the septic system slopes to the northwest. The new trench will be constructed parallel with the contours of the sloPe as mUCh as possible in conformance with Municipal requirements. The new septic system will be constructed a minimum of 100' from all wells and any surface water and 10' the proposed and existing water services in the area. If the system is constructed in accordance with our design the following statements apply: The system, if constructed as designed, will have no adverse impact on the wells in the area or those to be constructed in the future. The system, if constructed as designed, will have no adverse impact on existing septic systems in the area or those to be constructed in the future. The system, if constructed as designed, will have no adverse impact on reserve space, either surface or subsurface, on any lots located in the area. The system, if constructed as designed, will have no adverse impact on drainage patterns in the area. The current drainage pattern will be maintained. Sincerely, Michael E. Anderson, P.E. Attachments 7 LOT 8, BLOCK 4, SHANGRI-LA EST. EAST SUBDIVISION DESIGN FACTORS: Four Bedroom Home Perc. Rate: <1 Min./Inch Application Rate: 5 GPD/SF SYSTEM REQUIREMENTS: 5' Wide Trench System Four Bedroom Advantex Treatment System with AX-20 Pod - Gravity Flow .5' Dreinfield Rocld2' Filter Sand 4 Bedrooms * 150 GPD/Bedroom = 600 SF Absorption Area 600 SF/5 GPD/SF/5 SF (Width) = 24 LF Trench Length THEREFORE: Construct a 25' Long x 5' Wide x .5' Effective Depth Absorption Trench, Flow Line Elevation in Trench to be 4' Below Odginal Ground Surface. Total Depth to be 6' Below Existing Ground. Provide 3' Cover Over Absorption Trench and 4' Cover Over Septic Tank. Gravity Flow From Pod to Absorption Field. 2~ .........~eotextile Fabric % 4" Perforated PVC (Holes Down) Drainfield Rock rFilter Sand TYPICAL 5' WIDE TRENCH__ ..,--_,,, ,,-...SECTION NUH-: uraae ~rea uver/rencn [o uraln Away. . ~ / · · , · ~ F 49~ Minimum 6 Separabon From Bedrock. ..~ .......... . .......... ~.....~ Minimum 4' Separation From Groundwater. ~ ~ Minimum 100' Separation From Private Wells in the Area. ~ .,c~.~.~.;~"?~ Minimum 100 Separation From Su~ce Water or Streams: ~..b%~ N~. c~-~ · ~ ~...~ -'~ ~ESS~~ W.O,# 05716 DHI CONSULTING ENGINEERS 800 E. D~MOND BLVD. SUI3E 3-545 ANCHORAGE, ALASKA g9515 SOILS LOG-PERCOLATION TEST { ) TEST OLE LOG LGB, P~FORMEO FOR-ANCHORAGE DEVELOP. &: CONST. DAT~ PERFORaEO: 4-/14/11 '-,-9:'. ,~- LEGAL DESCRIP130N: LOT 8, BLOCK 4 SHANGRA-LA ESTATES EAST SUBD. .,'v, ~ 1' SLOPE SITE PLAN ..A,', ORGANrC MA'fL· I . 5 '~.": .- GREY-BROWN SLIGHILY SILT¢ "., SANDY GRAVEL.,~. ROCK TO 12". · ,' ~ NON-CLUMPING. 7 4-. 8 "' :' ":." .: ENCOUNTERED ? NO L 9 !, ,~ .' ~r YES, AT ~14AT 10 ~ B.O.H,, DEPTH ? E FRACTURED BEDROCK DEP"I3-I OF WATER 11 AFTER MONITORING ? NONE DATE: MAY 13, 2011 14 15 16 17 PEROOLA'nON RATE: 0,,¢ (blINU'TES/INCH.) PERCHOLE DIAMETER:_ TEST RUN BETWEEN: 5.0 FT. AND 5,5 FT, COMMENTS: THIS TEST HOLE INFORMATION IS PROVIDED TO COMPLY WITH THE SUBDIVISION APPROVAL PROCESS AS OUTLINED IN AMC 15,6.180.B.1, ANY USE OF THIS DATA FOR ANY OTHER PURPOSE, INCLUDING THE DESIGN OF AN INDIVIDUAL SEPTIC SYSTEM IS STRICTLY PROHIBrrED, WITHOUT THE WRITTEN CONSENT OF THE ENGINEER OF RECORD. l PRIOR TO STARTING THE PERCOLATION TEST. ALL SOILS WERE PRE-SOAKED PERFORMED BY: DHI CONSULTING ENGINEERS. I DEE HSGH CF-I~IIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES rN EFFECT ON THIS DATE. DATE: ,.2/07/06 7160SSCBD 345 6 789 'l, 70 � if:_ �,-.wz. > ' c� Municipality of Anchorage ' ' , On-Site Water and Wastewater Program a ���' (907) 343-7904 �' f e i k ! S A F E T Y l N 0! ', Certificate of On-Site Systems Approval 6 a g 5 n E 3 VM Parcel I.D. 020-043 Expiration Date: D I S- 1. GENERAL INFORMATION Complete legal description Shangri-La Estates East Block 4 Lot 8 Location (site address) 16357 Mountain Breeze Current Property owner(s) Richard S Harvey Day phone Mailing address P.O. Box 111816, Anchorage AK, 99511 Real Estate Agent Day phone 2. TYPE OF DWELLING: O Single Family (w/wo ADU) n Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) 3. NUMBER OF BEDROOMS: 4 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well x Individual E Individual Water Storage n Holding Tank ❑ Community Class Well n Community Public Water System ❑ Public Sewer ❑ WaiverNariance request for: Distance: Received by. 44=7 Date: S�ZS/jF COSA to be released to the engineer,unless otherwise requested by the engineer. COSA Fee $ 52L Waiver Fee $ Date of Payment 51 2J) Date of Payment Receipt Number ()0006 D Receipt Number COSA# d J6-i� 1 !?' Waiver# 5. . STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm Forge Engineering Phone (907) 522-7773 Address PO Box 240773 Anchorage, AK 99524 Engineer's Printed Name Michael E. Anderson, PE Date 5/21/18 6. DSD SIGNATURE ;,,*• 49 TH • � .� System#1 Approved for 14 bedrooms /�' •' Michael E.Anderson nderson : System#2 Approved for bedrooms l�Oh, Disapproved Conditional approval for bedrooms, with the following stipulations: OF ANC/7• •� ON_SC�E D . \NPRNP EK 0o o W pR°`-' r` By: .P t• En jv. oc� 11' (cle I u:'c Original Certificate Date: My 23 PO& The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On-Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: COSA Checklist X Nitrate Advisory Septic System Advisory Arsenic Advisory Well Flow Advisory Other COSA blue sheet f '• c If more than 1 septic system is on the lot: COSA Checklist# of Structure served by this system Certificate of On-Site Systems Approval Checklist Legal Description: Shangri-La Estates East B4 L8 Parcel ID: 020-043-78 A. WELL DATA Well type Private If A, B, or C provide PWSID# Well Log (Y/N) Y Date completed 6/13/15 Sanitary seal (Y/N) Y Wires properly protected (Y/N) Y Total depth 207 ft. Cased to 13* ft. Casing height(above ground) 24 in. FROM WELL LOG AT INSPECTION Date of test 6/13/15 5/18/18 Static water level 34 ft. 33 ft. Well production 6 g.p.m. 4 0 g.p.m. WATER SAMPLE RESULTS:( Coliform !�/e colonies/100 mL Nitrate MO O mg/L Arsenic !V D ug/L Date of sample: 5/7/18 Collected by: Forge Engineering B. SEPTIC/HOLDING TANK DATA Tank Type/Material Advantex FAP/Fiberglass Date installed 5/12/15 Tank size 1500 gal. Number of Compartments 2 Cleanouts (Y/N) Y Foundation cleanout(Y/N) Y Depression over tank (Y/N) N High water alarm (Y/N) Y Date of pumping Pumper Maintenance services provided by Anchorage Tank C. ABSORPTION FIELD DATA Date installed 5/11/15 Soil rating (g.p.d./ft2 or ft2/bdrm) 5 System type 5-Wide Length 25 ft. Width 5.0 ft. Gravel below pipe 0.5 ft. Total depth 3.8 ft. Eff. absorption area 125 ft2 Monitoring tube Y Depression over field N Date of adequacy test 5/18/18 Results (Pass/Fail) Pass For 4 bedrooms Fluid depth in absorption field before test 0 in. Water added 612 gal. New depth 0 in. Elapsed Time: 1440 min. Final fluid depth 0 in. Absorption rate >= 600 g p d None Any rejuvenation treatment (past 12 mo.) (Y/N &type) If yes, give date D. LIFT STATION Date installed Size in gallons Manhole/Access (Y/N) "Pump on" level at in. "Pump off' level at in. High water alarm level at in. Datum Cycles tested Meets alarm&circuit requirements? E. SEPARATION DISTANCES WELL ON LOT TO: Septic tank/lift station on lot >100' On adjacent lots >100' Absorption field on lot >100' On adjacent lots >100' Public sewer main >75' Public sewer manhole/cleanout >100' Sewer/septic service line >25' Holding tank >75' Animal containment areas >50' Manure/animal excrete storage areas >100' SEPTIC/HOLDING TANK ON LOT TO: >5' >5' Building foundation Property line >5' Absorption field Water main >10' Water service line >10' Surface water >100' Wells on adjacent lots >100' ABSORPTION FIELD ON LOT TO: >10' >10' >10' Property line Building foundation Water main Water Service line >10' Surface water >100' Driveway, parking/vehicle storage >10' Curtain drain None Noted Wells on adjacent lots >100' F. COMMENTS *4.5" PVC Liner from 12' to 52' Below the surface. G. ENGINEER'S CERTIFICATION I certify that I have determined through field inspections and ,���OF*k\ review of Municipal records that the above systems are in . , A�.gSiil conformance with MOA COSA guidelines in effect on this date. 40.4:...-.� `I,•.'f��# Engineer's Printed Name Michael E. Anderson, PE 0*: *:'49 TH /\ %.*00 Date 5/21/18 I % Michael E.Anderson e �ri V- 4381-E .**4-k40 COSA brown sheet 10-10-12.doc ADVANCED WASTEWATER TREATMENT SYSTEM MAINTENANCE AND REPAIR AGREEMENT BETWEEN MUNICIPALITY OF ANCHORAGE AND STERLING RIPLEY Y. THIS MAINTENANCE AND REPAIR AGREEMENT made and entered into as of this 21ST Day of MAY of 20 18,by and between STERLING RIPLEY J12., herein the"OWNER,"and the Municipality of Anchorage,herein the "MUNICIPALITY." In consideration of the mutual covenants contained herein,the parties to this Maintenance and Repair Agreement agree as follows: 1. Advanced Wastewater Treatment Systems. Municipality grants permission to Owner to utilize and operate an Advanced Wastewater Treatment System (AWWTS),described as ADVANTEX WASTE WATER TREATMENT SYSTEM located at(legal description). SHANGRI-LA ESTATES EAST L8 B4 2. Definitions. Alteration. Any change to the design or function of an AWWTS that includes the installation or removal of any parts,components or pieces not included in the original construction permit and design. Certificate of On-Site Systems Approval (COSA). An approval by the Municipality of existing water and wastewater disposal systems given at the time of property sale and title transfer in accordance with Anchorage Municipal Code (hereinafter, "AMC") 15.65. These approvals certify that the systems are adequate for the homes that they support and meet the codes that were in place at the time of system construction. Damage. Any man-made or natural change in a system that would inhibit the system from performing as designed. Maintenance and Repair. The scheduled and as needed replacement of existing parts, components and pieces of an AWWTS that were included in the original design which would allow the AWWTS to continue to perform as designed. Permit.An On-Site Wastewater Disposal Permit as required by AMC 15.65 to construct and operate an AWWTS. 3. Term. The term of this Maintenance and Repair Agreement shall begin on the date of approval by the Municipality to operate the installed system or issuance of a COSA, and shall continue while the AWWTS is in use or is operational or until the property is sold or title is transferred by the owner and a new COSA is issued to the new owner or transferee of the property. 4. Alterations,Installation and Removal of Additional Equipment. Prior to performing any alterations to an AWWTS,the owner agrees to obtain an On-site Wastewater Disposal Permit from the Municipality in accordance with AMC 15.65. 5. Maintenance and Repairs. A. Throughout the term of this Maintenance and Repair Agreement,the Owner shall maintain their AWWTS in a satisfactory condition capable of producing treated septic effluent in accordance with the equipment's approval for operation in the Municipality. The owner shall enter into a service agreement with an AWWTS service and maintenance provider approved by the municipality and the manufacturer of the AWWTS for the entire term of the AWWTS. In addition,it shall be the responsibility of the Owner during the term of this Maintenance and Repair Agreement, and any renewals thereof,at the owner's sole expense,to pay for any and all: (1)repair(s),(2)maintenance, (3)adjustment(s), (4)replacement costs, and(5) inspection costs. B. Owner agrees to comply with all applicable ordinance, laws,regulations,rules and orders for the AWWTS. C. Upon request by the Municipality,the owner agrees to provide the Municipality a written schedule of routine maintenance and repairs which have been performed on the system. When a record of maintenance is documented and maintained by the system vendor,the owner agrees to allow the Municipality access to this information. D. Owner acknowledges that the fine for failing to maintain and repair an AWWTS may be assessed in accordance with AMC 14.60 for improper discharge. E. Owner agrees that only maintenance and repair personnel approved by the Municipality will inspect and make any necessary maintenance,repairs or permitted alterations to the system. F. Owner agrees to grant the Municipality reasonable access to test and inspect the AWWTS upon 24 hours written notice. G. Owner agrees that any sale or transfer of title of the property will not occur without a new Certificate of On-Site Systems Approval. H. Owner agrees that the AWWTS installation and maintenance requirements as provided by the AWWTS vendor/installer and approved by the Municipality are the governing guidelines for the construction,maintenance and repair of the Owner's AWWTS. 6. Nonwaiver. The failure of either party at any time to enforce a provision of this Maintenance and Repair Agreement shall in no way constitute a waiver of the provisions,nor in any way affect the validity of the Maintenance and Repair Agreement or any part hereof, or the right of such party thereafter to enforce each and every provision hereof. 7. Amendment. A. This Maintenance and Repair Agreement shall only be amended,modified or changed by a writing,executed by authorized representatives of the parties, with the same formality that this Maintenance and Repair Agreement was executed with, and such writing shall be attached to this Maintenance and Repair Agreement as an amendment. B. For the purposes of any amendment modification or change to the terms and conditions of this agreement,the only authorized representatives of the parties are: a. Owner: STERLING RIPLEY Jj2. b. Municipality: Director,Community Development or designated authority C. Any attempt to amend,modify, or change this contract by either an unauthorized representative or unauthorized means shall be void. 8. Jurisdiction: Choice of Law. Any civil action arising from this Maintenance and Repair Agreement shall be brought in the Superior Court for the Third Judicial District of the State of Alaska at Anchorage. The laws of the State of Alaska shall govern the rights and obligations of the parties under this Maintenance and Repair Agreement. 9. Severability. Any provisions of this Maintenance and Repair Agreement decreed invalid by a court of competent jurisdiction shall not invalidate the remaining provisions of the Maintenance and Repair Agreement. OWNER: (signature) Date: 51/4/ i 8 l S 'l C . int name) STATE OF ALASKA ) ) ss. THIRD JUDICIAL DISTRICT ) The foregoing instrument was acknowledged before me thisZL day ofkCe - 20 ,by :>k-Y kk�n j State ofAlaska NOTARY PUBLIC NOTARY PUBIC•'OR ALASKA j Kara'lirviford My Commission expires: . 202.1 j My comn,tsston Was x.14,2021 MUNICIPALITY: By: (signature) Date: .�r Z 3 -/ (print name) Title: 05/31/2017 04:44 8686770 APLUS PAGE 06 288038 ■■Mi t+r s no ■■M■ MMR III MiIi. ill. ■Ai I 11 ii I M l ilii ■ M ■ i• ■■ iI ■ PU IS ■ I III IN i■i■ Milli I RIM Mill • 0 Advarirrexe Field Maintenance Report AnchorageTank Annual Inspection 907-272-3543 opornta Property 0w0 T na00 Larry BettsShane Harvey Conine see Add�ass (907)980-1676 16357 Mountain Breeze Drive, Anchorage AK 99516 ��� Date a�t � Co""�1D f Pod 11 RTU 12/15/2016 ion AX Site ID a RTU 131953 AX137605 1 OSP151056 422165 Retrieve O&M Info Measure Sludge/Scum own Daily flow Sludge S_ _ — 1St Compartment Currgnt Previous Current Previous Recirc ratio Ti _ /?J ,t mer settings 2nd Compartment Current Previous Current Previous Inspect/Clean Advantax Filter Inspect Clean Odor: .EirkiOm,ai ❑Pungent Laterals/Orifices-'-" ""t'' Perform Field Sampling/Observations 8lomat: Normal ❑Excessive Pod Bottom -- • NTU(16 e NTUs) pH(6-9) DO(2-6) Briddging/Ponding: None/Mlnor ❑Excessive Intake Vent /a-OC 9. 1 Inspect/Clean Discharge Pump System JJ VV 11 Inspect inspect Clean Odor of Sample Rlser/Lid CI no CI CITypical Zi Musty ❑Earthy ❑Moldy Splice Box El Pump ❑ ❑ Non-typical W$uHlde ❑Cabbage ❑Decay Float cords [-i� Oily tnm in pw ❑Yea eNo d5 Inspect/Service Other System Components inspect Clean Foam in tank ❑Yes /�No Inspect Clean Check Control Panel Disinfection Equipment C� .nt / '� Olsperaal t.aterals/OTt ice�� '�^ ReeirC Amps Discharge AmPa Observations t/v^ L Additional Services R `dared — — ❑Cleaned textile ahem? ❑Replaced UV items? Audible and visual alarms zoK ❑Replaced/Used other Items? Dial tone(telemetry only) C Yes,rel No Parts Used:W=Warranty,B e Billable(✓appropriate selection) inspect/Clean Pump System w 13 Item Number Description InClean Fliser/Ud "P:irr Splice Box Float Cords Floats rU Final/Safety Inspection -+ tSV reinstalled '[_I�Sda bolted on Pump vrrJ •n Control ,Z 0 �anlfakJ reconnected;flush valves closed Control panel reactivated Biotube Pump Vault ✓ ( Summary/Recommendations El XJ System performing;no further action needed ❑Tank needs pumping Recirculating Splitter Valle — El Call for service ❑Other? Comments Date �1/ttcf /7 Signature - Fax Completed form to 1-666-884-7404