HomeMy WebLinkAboutBEAR RIDGE LT 9Bear Ridge Lot 9 #067-621-15 Municipality of Anchorage On -Site Water and Wastewater Program • (907) 343-7904 Page of ON-SITE WASTEWATER INSPECTION REPORT Permit Number: OSP151119 PID Number: 067-621-15 Dwelling: ■ Single Family (SF) ❑ Duplex (D) ❑ Multiple (SF and/or D) Project: • New ❑ Upgrade Name: Troy Davis Homes ABSORPTION FIELD Address 165 E. Parks Hwy #200 Wasilla, AK 99654 El Deep Trench ■ ❑ Other Shallow Trench ❑ Bed ❑ Mound Phone 357-9394 Number of Bedrooms 3 Soil Rating .8 GPD/SF Total depth from original grade 9.6 Ft. LEGAL DESCRIPTION Depth to pipe invert from original grade Gravel depth beneath pipe Subdivision Block Lot 3.6 Ft. 6 Ft. Bear Ridge 9 Fill added above original grade Gravel length Township Range Section 1-2 Ft. 47 Ft. Gravel width Beds: Number of Lines Distance between lines SEPARATION DISTANCES 3 Ft. Ft. To From Septic Tank Absorption Field Lift Station Holding Tank Sewer Line Total absorption area 5564. Ft2 Number of trenches 1 Dist. between trenches Ft. Well >100' >100' >100' >75' >25' TANK ❑ Septic ■ S.T.E.P. • Holding ■ Other Manufacturer Capacity Surface Water >100' >100' >100' NA Anchorage Tank 1,000 Gal. Material Steel Number of compartments Two Lot Line >5' >10' >5' NANA Foundation >5' >10' >5' NA LIFT STATION Manufacturer Capacity Gal. Curtain Drain None Noted Remarks Pump on level at Pump off level at High water alarm at in. in. in. Pump make and model Electrical Inspections performed by Installer PIPE MATERIAL House to tank D3034Tank to 03034 drainfield Northern Excavation DrainfieldF810 CO/MTD3034 Inspector W. Roberts BENCH MARK (Assumed elevation) 100.0 ft Inspection1m 5/28/15 2"' 5/28/15 Location and description 3" 9/20/15 dt° Bottom of Siding. COMMUNITY DEVELOPMENT DEPARTMENT APPROVAL Conditional Approval: Date ':;" s tam �"�• OF''4$ 4 t a!dSP,: ' S�,O ,.*; 49TH•••'*o owt 1 Approve,. ✓ pp vl�� i-Dd % ' J #& Dated 2' 3-410400- i4 or e 0 .MICHAEL E. ANDERSON :,,,..1 �'. CE -4381 �`�® v1'-^y'•.,.-Zz-r3.•,,, , e� 444 /'ROFES510.°- o�� Inspection Rep6rt_9-1-12.doc i 0 3 0 0 W 0 C 0 d C N = O0 C F N J N 0 00 N 0> - 0 t Cn O2 - 3 C O V) 0 a d p 5 I -OO ui I I I I I I I— 0 T 000 > _ M u_i-ONU)5 I I ti Esz \N 2O`pS ®>. W 1- 0) W a z W J z N r�P••. o.-z4t.1111 • N00`07'00"W x.00 Municipality of Anchorage DEVEOPMENT SERVICES DEPARTMENT 4700 Elmore Road Anchorage, AK. 99519-6655 - 343-7904 On -Site Wastewater Disposal System or Well Inspection Report Permit Number: OSP151119 93.5 98.5 c'j Original / Finished Grade 93.9 1,000 Gallon Septic Tank 3.75 Page 3 of 3 PID No. 067-621-15 Original Ground r Geotextile Fabric Drainfield Rock 87.52 -744- No Groundwater 8-28-14 87.52 47 (T nch Length) PROFILE AS -BUILT No Scale O 4'1 4: 4f9tht• • ' * $ 93.5 MICHAEL E. ANDERSON . Na CE -4381 ' 1 hli, OFE�1�Se GO 4 - MUNICIPALITY OF ANCHORAGE DEVELOPMENT SERVICES DEPARTMENT 4700 BRAGAW STREET ANCHORAGE, AK 99519-6650 SOILS LOG - PERCOLATION TEST LEGAL DESCRIPTION: BEAR RIDGE SUBDIVISION, LOT 9 PERFORMED FOR: TROY DAVIS HOMES INC. DATE 5/28/15 PROJECT No.: PARCEL ID#: 067-621-15 TECHNICIAN: W. ROBERTS 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 TEST HOLE 2 OB/OG SILTY GRAVEL WITH SAND GM BOH @ 16' SLOPE SEE SITE PIAN WAS GROUND WATER ENCOUNTERED' NO IF YES @ WHAT DEPTH? DEPTH OF WATER AFTER MONITORING: NONE DATE OF MONITORING. 6/5/2015 0 P E ...E OF r O • ; ■ 49th GV ''[S�,�,.�) EatA4 (4 M7 CHA�E'L E. ANDERSONL��, tC f NO. CE -4381 ��.h min3„.i. Professional Engineers Stamp: SITE PLAN SEE SITE PLAN SEE SITE PLAN DATE READING GROSS TIME (MINUTES) NET TIME (MINUTES) DEPTH To WATER (INCHES) NET DROP (INCHES) 5/28/15 TEST HOLE PRESOAKED PRIOR TO TESTING: I 2:14 1.25" 2 2:44 30 4.00" 2.75" 3 2:45 1.13" 4 3:15 30 3.88" 2.75" 5 3:16 1.50" 6 3:46 30 3.25" 2.75" PERCOLATION RATE: 10.9(MIN/INCH) PERC. HOLE DIA. 6 (INCHES) TEST RUN BETWEEN: 4.5 FT. and 5.5 FT. COMMENTS' TEST HOLE PRESOAKED PRIOR TO TEST. TEST PERFORMED BY ANDERSON ENGINEERING. I, MICHAEL E. ANDERSON CERTIFY THAT THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPLE GUIDELINES IN EFFECT ON THIS DATE: 9/22/15 Ca._ MUNICIPALITY OF ANCHORAGE DEVELOPMENT SERVICES DEPARTMENT 4700 BRAGAW STREET ANCHORAGE, AK 99519-6650 DEPTH (feet) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 SOILS LOG - PERCOLATION TEST LEGAL DESCRIPTION: BEAR RIDGE SUBDIVISION, LOT 9 PERFORMED FOR: TROY DAVIS HOMES INC. DATE: 10/7/2 015 PROJECT No • PARCEL ID#: 067-621-15 TECHNICIAN: MEA TEST HOLE 3 OB/OG SILTY GRAVEL WITH SAND GM BOH @ 3' WAS GROUND WATER ENCOUNTERED' IF YES @ WHAT DEPTH? DEPTH OF WATER AFTER MONITORING: NONE DATE OF MONITORING- 6/5/2015 SLOPE SEE SITE PLAN Na Professional Engineers Stamp: SITE PLAN SEE SITE PLAN SEE SITE PLAN DATE READING GROSS TIME (MINUTES) NET TIME (MINUTES) DEPTH To WATER (INCHES) NET DROP (INCHES) 10/7/15 TEST HOLE PRESOAKED PRIOR TO TESTING: I 2:22 0.50" 2 2:52 30 3.50" 3.00" 3 2:53 0.38" 4 3:23 30 3.38" 3.00" 5 3:24 0.50" 6 3:54 30 3.50" 3.00" PERCOLATION RATE: 10 (MIN/INCH) PERC. HOLE DIA: 6 (INCHES) TEST RUN BETWEEN: 2.5 FT. and 3.5 FT. COMMENTS• TEST HOLE PRESOAKED PRIOR TO TEST. TEST HOLE TO VERIFY SOILS FOR ALTERNATE SITE. SOILS IDENTICAL TO TEST HOLE NO. 2. TEST PERFORMED BY ANDERSON ENGINEERING. I, MICHAEL E. ANDERSON CERTIFY THAT THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPLE GUIDELINES IN EFFECT ON THIS DATE: 10/8/2015 Certified DrillingLi_g DOC COON; IBM ULLIVhN WATER WELLS P.O. Box 670269, Chuglak, AK 99587 888-2758 OWNER OF LAND: Sarah & David Bellville ADDRESS: 8070 Pioneer Rd Unit A, Anchorage, Ai{ 99504 LEGAL DESCRIPTION Bear Ridge Lot 9 DATE: 5.30-15 PERMIT NUMBER: OSP1S1119 DATE OF ISSUE: TAX IDENTIFICATION NUMBER 06762115000 Is well located at approved permit location: yes N0 air rotary ❑cable tool 5-12-15: Method of Drilling: a Depth of Well; 285' Casing Type: Steel Diameter: Liner type 6 Wall thickness ,250 inches, depth 285 inches feet Static Water Level: Flowing Recovery Rate 12 gpm Method of Testing Air El Well Intake Opening Type: I�„y open end ❑ Screened Start feet ❑ Perforations Start Met Grout Type: Bentonite Depth: from 2 feet, Well Disinfected Upon Completion: Method of Disinfection: Chlorine feet gph open hole Stopped Stopped Volume: 50 Ibs to 42 yes LJ no 0 PPM Comments: Bore Hole Data Depth From To 0 2 2 4 4 20 48 20 48 171 171 185 185 279 279 285 Casing Sticku Overburden Sand and Gravel Hardpan Tight Silt and Gravel Silty Sand and Gravel with Clay Tight Silty Gravel with Clay Sand and Gravel Drillers Name: Cole Sullivan ATTENTION: It Is the responsibility of the property owner to submit a copy of the well log to the proper authority. Municipality of Anchorage: Department of Health & Human Services and/or Department of Environmental Conservation. MatSu Borough: Department of Environmental Conservation. Coliform N e4 . Col/1 OOmL Nitrates o • 9' a mg/1. Arsenic N D ug/U Bore Hole Data Depth From To 0 2 2 4 4 20 48 20 48 171 171 185 185 279 279 285 Casing Sticku Overburden Sand and Gravel Hardpan Tight Silt and Gravel Silty Sand and Gravel with Clay Tight Silty Gravel with Clay Sand and Gravel Drillers Name: Cole Sullivan ATTENTION: It Is the responsibility of the property owner to submit a copy of the well log to the proper authority. Municipality of Anchorage: Department of Health & Human Services and/or Department of Environmental Conservation. MatSu Borough: Department of Environmental Conservation. SOLif,itN WATER WELLS P.O. Box 670269, Chugiak, AK 99567 688-2759 www.sullivanwaterwells.com Pump Installation Log Well Drilling Permit Number: SW O5P151119 Date of Issue 5-12-15 Parcel Identification Number: 06762115000 Legal Description Bear Ridge Lot 9 Property Owner Name & Address David & Sarah Bellville 8070 Pioneer Dr. Unit A, Anchorage, AK 99504 Pump Installation Date: 6-18-15 Pump Intake Depth Below Top of Well Casing: 250' Pump manufacturer's Name: Goulds Pump Model: 75B07412CL Pump Size: 3/4 hp Pitless Adapter Burial Depth: 10' feet Pitless Adapter Installer: Northern Excavating Disinfected Upon Completion? I yes ❑ no feet Method of Disinfection: Chlorine 50 PPM Comments: Pitless Manufacturer: Martinson Pump Installers Name: Cole & Terry—Sullivan Water Wells Attention: The pump installer shall provide a pump installation log to the DSD within 30 days of pump installation. On -Site Water & Wastewater System Permit MUNICIPALITY OF ANCHORAGE Development Services Department On -Site Water & Wastewater Program 4700 Elmore Road, PO Box 196650 Anchorage, AK 99519-6650 Telephone: (907) 343-7904 Permit Number: OSP151119 Tax Code Number: 06762115000 Work Type: WellSeptic Initial Permit Effective Dates: May 12, 2015 to May 11, 2016 Design Engineer: ANDERSON ENGINEERING Subdivision: BEAR RIDGE Site Legal Address: BEAR RIDGE LT 9 G:0804 Owner/Address: BELLVILLE DAVID P & SARAH M 8070 PIONEER DR UNIT A ANCHORAGE AK 995040000 Site Mailing Address: 3322 BEAR RIDGE CIR, Eagle River Lot Size in Sq Ft: 40946 Total Bedrooms: 3 This permit is for the construction of: Y Disposal Field Y Septic Tank N Holding Tank N Privy Y Private Well N Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80). 3. The wastewater code requires inspections during the installation. The engineer must notify the -Development Services Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either: A. Open and Close on the same day. B. Covered, sealed, and heated to prevent freezing. Received By: j /V Date: Issued By: �'f V t! Date: S" CUBM!TTAI MAY 11 2015 MUNICIPALITY OF ANCF9CYRiNer N' JCommunity Development Department Development Services Division On -Site Water & Wastewater Program Phone: 907-343-7904 ON-SITE SEWER/WELL PERMIT APPLICATION Parcel I.D. 067-621-15 Property owner(s) David & Sarah Bellville Day phone Mailing address 8070 Pioneer Drive Unit A Anchorage, AK 99504 Site address 3322 Bear Ridge Circle Eagle River, AK 99577 Legal description (Sub'd., Block & Lot) Bear Ridge, Lot 9 Legal description (Township, Range & Section) Lot Size 40,496 Sq. Ft. Number of Bedrooms Three APPLICATION IS FOR: APPLICATION IS AN: (® all that apply) Absorption Field Septic Tank Holding Tank Privy Private Well Water Storage Initial Upgrade Renewal 0 TYPE OF DWELLING: Single Family (SF) (w/wo ADU) Duplex (D) Multiple Dwellings (SF and/or D) THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR: Distance: 0 I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit/Rush Fees: 41 a51-1•'JQ Date of Payment: Receipt Number: 001-0atli Permit No. Os P161119 5/11/15 Permit App_9-1-12.doc Waiver Fees: Date of Payment: Receipt Number: Waiver No. ANDERSON ENGINEERING P.O. BOX 240773 ANCHORAGE, AK 99524 522-7773 677-7766 (FAX) May 10, 2015 Municipality of Anchorage Development Services Department On -Site Water and Wastewater Program 4700 South Bragaw Street Anchorage, AK 99519-6650 Subject: Lot 9, Bear Ridge Subdivision Septic System Design and Permit Application Impacts to Adjacent Properties Dear Onsite Services Engineer: The owner of Lot 9, Bear Ridge Subdivision intends to construct a new three-bedroom home on the lot. We are therefore requesting a permit be issued for the construction of a new well and septic system to accommodate the home. The attached Site Plan and backup documentation identify the location and configuration of the proposed well and septic system along with the alternate site. Also identified on the plans are the existing wells and septic systems on surrounding lots. No conflicts exist between the proposed septic system and well or septic systems and wells on adjacent lots. Drainage arrows and surface contours are shown on the site plan showing the grade and direction of flow on the lot. The drainage pattern will not be changed as a result of this project. The test hole placed on the lot in the area of the absorption trench and alternate site indicate silty gravel (GM) with sand in the zone specified for the absorption trench. The percolation rate of the soil was determined to be 10 minutes per inch. No groundwater was found during the placement of the test hole and none developed during the monitoring period. An application rate of .8 gallons per day per square foot was used in the design of the absorption system. We are proposing to place a new 1,000 -gallon septic tank and a 47' long by 3' wide by 6' effective depth absorption trench to treat and dispose of the effluent generated in the house. The elevation of the distribution line in the absorption trench will be 3' below the surface and the total depth will be 9'. A minimum of 3' of fill or 2" of insulation and 2' of fill will be placed over the absorption trench and 4' over the septic tank. The ground surface on the lot in the area of the septic system slopes to the southwest. The new trench will be constructed parallel with the contours of the slope as much as possible in conformance with Municipal requirements. The new septic system will be Lot 9, Bear Ridge May 10, 2015 Page Two constructed a minimum of 100' from all wells and any surface water and 10' the proposed and existing water services in the area. If the system is constructed in accordance with our design the following statements apply: 1. The system, if constructed as designed, will have no adverse impact on the wells in the area or those to be constructed in the future. 2. The system, if constructed as designed, will have no adverse impact on existing septic systems in the area or those to be constructed in the future. 3. The system, if constructed as designed, will have no adverse impact on reserve space, either surface or subsurface, on any Tots located in the area. 4. The system, if constructed as designed, will have no adverse impact on drainage patterns in the area. The current drainage pattern will be maintained. Sincerely, Michael E. Anderson, P.E. Attachments • • 0 N -----CO- N I 0 c J y 6 Q > H O O c Ill L O 6 0 N O Z .+ c � 3a.)>0 O lei coo 0 a p j 0 M I-0 V)M OF Z I 1 1 1 ILIJ l 1 O w E- IL0HU t00 O mN fn1 >I z Q J LLJ F - v 11 7 F z I HAEL N00.07'00"W 50.00 LOT 9, BEAR RIDGE SUBDIVISION DESIGN FACTORS: Three Bedroom Home Perc. Rate: 10 Min./Inch Application Rate: .8 GPD/SF 3 Bedrooms X 150 GPD/.8 GPD/SF (Application Rate) = 562.5 SF Absorption Area 562.5 SF/12 SF/LF = 46.875 LF Trench Length THEREFORE: Construct a 47' Long x 3' Wide x 6' Effective Depth Absorption Trench at the Location Shown on the Site Plan. Flow Line Depth to be 3' Below Existing Ground. Total Depth of Trench to be 9' Below Existing Ground. Provide Minimum 4' Cover Over Septic Tank and 3' Cover Over Absorption Trench. Maintain 100' Separation From All Wells in the Area. SYSTEM REQUIREMENTS: Deep Trench System 1,000 Gallon Septic Tank 6' Drainfield Rock 2'6" 6'0" Natural Backfill Geotextile Fabric 4" Perforated 3' PVC (Holes Down) TYPICAL DEEP TRENCH (NO SCALE) NOTE: Grade Area Over Trench to Drain Away. Minimum 6' Separation From Bedrock. Minimum 4' Separation From Grouridwa Minimum 100' Separation From Wells in Minimum 100' Separation From Surface Drainfield Rock SECTION ....��-•444�� PI :. •49th TF 4 - L ter. }}yy the Area. •jjMICHAEL E. ANDERSON g: Water or Streams. ♦ . No. CE-4381 kir, MUNICIPALITY OF ANCHORAGE DEVELOPMENT SERVICES DEPARTMENT 4.700 BRAGAW STREET ANCHORAGE, AK 99519-6650 SOILS LOG - PERCOLATION TEST LEGAL DESCRIPTION: BEAR RIDGE SUBDIVISION, LOT 9 PERFORMED FOR: TROY DAVIS HOMES. INC. DATE: 4/18/15 PARCEL ID#: 067-621-15 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 OB/OG PROJECT No TECHNICIAN• W. WHALEY TEST HOLE 1 SILTY GRAVEL WITH SAND GM BOH @ 15' SLOPE SEE SITE PLAN WAS GROUND WATER ENCOUNTERED? NO IF YES @ WH DEPTH OF WATER AFTER MO1 DATE OF MO 114 49th Cts, 0 MICHAEL E. ANDERSON ••t ' No. CE -4381 ? ♦rT Professional Engineers Stamp: SITE PLAN SEE SITE PLAN T DEPTH" ITORING: NONE 0 SEE SITE PLAN ,IITORING. 5/10/2015 P E DATE READING GROSS TIME (MINUTES) NET TIME (MINUTES) DEPTH To WATER ( INCHES) NET DROP (INCHES) 4/18/15 TEST HOLE PRESOAKED PRIOR TO TESTING: I 1:31 0.75" 2 2:01 30 3.75" 3.00" 3 2:02 0.63" 4 2:32 30 3.6Y 3.00" 5 2:33 0.63" 6 3:03 30 3.63" 3.00" PERCOLATION RATE: 10 (MIN/INCH) PERC. HOLE DIA. 6 (INCHES) TEST RUN BETWEEN: 4.0 FT. and 5.0 FT. COMMENTS' TEST HOLE PRESOAKED PRIOR TO TEST. TEST PERFORMED BY ANDERSON ENGINEERING. 1, MICHAEL E. ANDERSON CERTIFY THAT THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPLE GUIDELINES IN EFFECT ON THIS DATE: 5/10/2015 rs Municipality of Anchorage On -Site Water and Wastewater Program (907) 343-7904 Certificate of On -Site Systems Approval Parcel I.D. 067-621-15 Expiration Date: 1. GENERAL INFORMATION r/g* Complete legal description Bear Ridge, Lot 9 Location (site address) 3322 Bear Ridge Circle Eagle River, AK 99577 Current Property owner(s) Troy Davis Homes, Inc. Day phone 357-9394 165 E. Parks Highway, No. 200 Wasilla, AK 99654 Mailing address Real Estate Agent Day phone 2. TYPE OF DWELLING: Q Single Family (w/wo ADU) ❑ Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) 3. NUMBER OF BEDROOMS: Three 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well E Individual Q Individual Water Storage ❑ Holding Tank ❑ Community Class Well ❑ Community ❑ Public Water System - ❑ Public Sewer ❑ WaiverNariance request for: Distance: Received by: Date: Af--f /! COSA to be relea d to the engineer, unless otherwise requested by the engineer. COSA Fee $ (0q 8° Waiver Fee $ Date of Payment 9/21-1/K c 0 Date of Payment Receipt Number 065714G Receipt Number COSA # 05C16 l5K( Waiver # 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm Anderson Engineering Address P.O. Box 240773 Anchorage, AK 99524 Engineer's Printed Name Michael E. Anderson, P.E. 6. DSD SIGNATURE System #1 Approved for System #2 Approved for Disapproved Conditional approval for By: bedrooms bedrooms Phone 522-7773 Date 9/2211Sve.t ®®aw® a �F OF AL tag p. S' � -•'° 49 l � _ .7%‘,0 AS roc •q°° i ,OBY•e lOq S9Y 99aq° q ate,• fuVCHAEI -ANDERSON ®�'rff'•,9 ZZ-/ S •� °mac, bedrooms, with the following stipulations: Original Certificate Date Th > unicipality of Anchorage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: COSA Checklist X Septic System Advisory Well Flow Advisory COSA blue sheetr - Nitrate Advisory Arsenic Advisory Other If more than 1 septic system is on the lot: COSA Checklist # of _ Structure served by this system Certificate of On -Site Systems Approval Checklist Legal Description: Bx10 r R1 cLG / Lo -t- q A. WELL DATA Well type A r i V If A, B, or C provide PWSID # Well Log (Y/N) y Date completed 5/12/15 Sanitary seal (Y/N) Y Wires properly protected (YIN) y Total depth AS5 ft. Cased to a85 ft. Casing height (above ground) > l8 in. FROM WELL LOG AT INSPECTION Date of test 5- !Z• 16 Static water level 1I0 ft. ft. Well production 12-- g.p.m. g.p.m. Parcel ID: 0(07— 1//2-1 WATER SAMPLE RESULTS: (, Coliform V colonies/100 mL Nitrate - fi() 2,/mg/L p �% Arsenic MD ug/L Date of sample: Q')0IP5 Collected by: Wean Gn(slyl-e-eriri B. SEPTIC/HOLDING TANK DATA C r- r ttt G �j J J Tank Type/Material ���(�f (�e1 Date installed v . Z -O . /5 Tank size 1 V 60 gal. Number of Compartments a Cleanouts (Y/N) y . 1 Foundation cleanout (YIN) y Depression over tank (Y/N) N High water alarm (Y/N) r 'v Date of pumping !Nevi enn Pumper C. ABSORPTION FIELD DATA pp� Date installed Soil rating (g.p.d./ft2 or ft2/bdrm) . O &PD/ SF System type�2f) Qk(ch Length 14. ft. Width 3 ft. Gravel below pipe IP ft. Total depth 1 i ft. Eff. absorption area 556+ tt2 Monitoring tube 7 Depression over field ki Date of adequacy test _14PJA) Cnl t4fQ llesults (Pass/Fail) For _ bedrooms Fluid depth in absorption field before test in. Water added gal. New depth in. Elapsed Time: min. Final fluid depth in.. Absorption rate >= Any rejuvenation treatment (past 12 mo.) (Y/N & type) N If yes, giva date g.p.d. ooptt-o -of laays umoiq VS00 9 FOZ/OZ/L a}ea '3•d 'uosiapuy '3 JOeyagAJ eweN pe}uud s,JeGulSu3 •euep situ uo page ur sewlaprn6 VS00 VOW gu/M ooueWJOJUon uu ode sweus fs anoge ow win spioocu ledplunpy Jo moped pun suogoadsw pay 115no qu pewwrouap emu 1 mil fppea l NOIIV014111130 S.1133NION3 'O 0 < e6eio}seplyan/6ulped'6eManuU V/N ulewas}eM 00 4< -a}eM eoellns plug uogdiosgy ,9< .001< SIN3WWO3 'd OO (< s}ol }ueoefpe uo suom pa}ON euoN Lipp wimp .001< 1G}eM aoepns 0 ix awl animas n}eM ,01< uol}epunoj6ulpung ,0i.< augAuedoJd :01101 NO 01314 NOIldUOSOV OO (< sup! }ueoefpa uo sum 0 4< awl ao!MJas Jae 0 J.< uiew JeleM Gull Rpedad 9< uol}epunol 6ulpung :01101 NO )INV! ONI01OH/o11d3S same e6eao}s a eioxe lewluafeJnuefy Nue} 6wploH .001< .9L< }noueelo/aloquew JOMOS ogled s}ou }ueoefpe up s}ol }ueoefpe up .001< .001< Esfuaws.nnbei flnono 9 uuele span ,9< 'ul 18 lana) WJele Ja}eM y61H 'u1 (N/A) sseooy/auoyueyy .09< ,9Z< OMB }uawule}uoo lewluy Gull GOIAIGs nudes/JOMOS ulew JOMOS wind ,006< .001< .001< }ol uo plug uondiosgy }quo uoue}s UII/Hue} nudes :01101 NO 113M S30NVISI0 NOIIVHVd3S '3 poise) sap p wn}ea 18 lana) ,Jun dwnd„ •ul 18 Wel „UO dwnd„ suoue6 ul 0zls pane}sul a}ea NOIIVIS 1411 '0 LOT 9 40,920 SQ.FT. OF AREA 10 BEAR RIDGE _ CIRCLE to o 00 9 i/A°°°0ti to 7 4 N N N w a" Ory 8 GRAPHIC SCALE: I Inch = 50 Feet 25 0 25 50 100 FOR: TROY DAVIS HOMES FORBES& ASSOCIATES, INC. F.O. BOX 232293 Anchorage, Alaska 90523 (007) 227-5881 Date 09-17-15 Seale 1" = 50' Grid SE 804 As—built Survey 2150159 Legal Description Lt9 Block Drawn by eef Field Book 246 BEAR RIDGE SUBDIVISION I hereby certify that the property described hereon has been surveyed by me, or at my direction, and that the improvements situated thereon are within the property lines and do not overlap or encroach on the property lying adjacent thereto unless otherwise shown. That no improvements on the property lying adjacent thereto encroach on the premises in question and that there are no roadways, transmission lines or other easements on said property except as shown. It is the responsibility of the owner or builder, prior to construction, to verify proposed building grade relative to finish grade and utility connections and to determine the existence of any easements, covenants, or restrictions which do not appear on the recorded subdivision plat. \ Listed distances prevail over scaling. \ Reproduction may cause distortion. %%%%lift 49TH 1 I1 ".,..0 :i '. CHARLES E. " . FORKS : of iffir ;riy. ", LS -7326 j'.: a'•, 091815 ae A f'�:er essieoe1gi14' '► 111%~ 1