HomeMy WebLinkAboutSCHROEDER EAST BLK 1 LT 16hroed r
ast
Block
Lot 16
#050-063 -08
Permit Number: OSP151134
Tax Code Number: 05006308000
Work Type: Septic
Permit Effective Dates: May 27= 2015
On-Site Wastewater Disposal System Permit
MUNICIPALITY OF ANCHORAGE
Development Services Department
On-Site Water & Wastewater Program
4700 Elmore Road, PO Box 196650
Anchorage, AK 99519-6650
Telephone: (907) 343-7904
Initial
to May 26, 2016
Design Engineer: ANDERSON ENGINEERING
Subdivision: SCHROEDER EAST
Site LegalAddress: SCHROEDER EAST BLK 1 LT 16 G:0352
Owner/Address: HARTLEY JUDY L
PO BOX 672067 CHUGIAK AK 995672067
Depa r tmel~t
Site Mailing Address: 17515 SANTA MARIA DR, Eagle River
Lot Size in Sq Ft: 21505
Total Bedrooms: 3
This permit is for the construction of:
Y Disposal Field Y Septic Tank N Holding Tank N Privy N Private Well N Water Storage
All construction must be in accordance with: 1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater
Disposal Regulations (18AAC72) and Drinking Water Regulations (ISAACS0).
3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services
Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either:
A. Open and Close on the same day.
B. Covered, sealed, and heated to prevent freezing.
Received By:
Issued By:
Date:
Date:
RUSH!
Community Development Department
Development Services Division
On-Site Water & Wastewater Program
ON-SITE SEWER/WELL PERMIT APPLICATION
Parcel I.D. 050-063-08
Property owner(s) Troy Davis Homes Day phone 310-2501
Mailing address 165 E. Parks Highway #200 Wasilla, AK 99654
Site address 17515 Santa Maria Drive Eagle River, AK 99577
Legal description (Sub'd., Block & Lot) Schroeder East, Block 1, Lot 16
Legal description (Township, Range & Section)
Lot Size 21,505 .Sq. Ft. Number of Bedrooms Three
APPLICATION IS FOR:
([] all that apply)
Absorption Field []
Septic Tank []
Holding Tank []
Privy []
Private Well []
Water Storage []
APPLICATION IS AN:
TYPE OF DWELLING:
Initial [] Single Family (SF)
(w/wo ADU)
Upgrade []
Duplex (D)
Renewal []
Multiple Dwellings
(SF and/or D)
THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR:
Distance:
I certify that the above information is correct. I further certify that this is in accordance with
applicable Municipal Codes.
(Signature of property owner or authorized agent)
Permit/Rush Fees:
Date of Payment:
Receipt Number:
Permit No.
q lO, 4O
OSPl lt q
Waiver Fees:
Date of Payment:
Receipt Number:
Waiver No.
May 26, 2015
Municipality of Anchorage
Development Services Department
On-Site Water and Wastewater Program
4700 South Bragaw Street
Anchorage, AK 99519-6650
Subject:
Lot 16, Block 1, Schroeder Subdivision East Addition
Septic System Design and Permit Application
Impacts to Adjacent Properties
Dear Onsite Services Engineer:
The owner of the subject lot intends to construct a three bedroom home. We are
therefore requesting a permit be issued for the construction of a new septic system to
accommodate the home. The attached Site Plan and backup documentation identify
the location and configuration of the proposed septic system. The subdivision is served
by the AWWU water system and a service will be extended to this lot. No existing wells
or septic systems are closer than 100' from the proposed septic system Drainage
arrows are shown on the site plan showing the grade and direction of flow on the lot.
The drainage pattern will not be changed as a result of this project.
The test hole placed on the lot in the area of the proposed absorption trench indicated
silty sand with gravel (SP/SM) material. The percolation rate of the soil was determined
to be 10.9 minutes per inch. Groundwater was found at 10' during the placement of the
test hole and stabilized at 10.5' below the surface during the monitoring period. A
recent inspection on May 27 indicated the water was at 11' below the surface. An
application rate of .8 gallons per day per square foot was used in the design of the
absorption system. We are proposing to place a new 1,250-gallon STEP tank and a 72'
long by 5' wide by 2.5' effective depth absorption trench to treat and dispose of the
effluent generated in the house. The elevation of the distribution line in the absorption
trench will be 3.5' below the surface and the total depth will be 6'. A minimum of 3' of
fill or 2" of insulation and 2' of fill will be placed over the absorption trench and 4' over
the septic tank.
The ground surface on the lot in the area of the absorption trench slopes to the
southeast at approximately 10%. The new trenches will be constructed parallel with the
contours of the slope as much as possible in conformance with Municipal requirements.
Lot 16, Block 1, Schroeder Subdivision East Addn.
May 27, 2015
Page Two
The new septic system will be constructed a minimum of 100' from all wells and any
surface water and 10' from the proposed and existing water services in the area.
If the system is constructed in accordance with our design the following statements
apply:
The system, if constructed as designed, will have no adverse impact on the wells
in the area or those to be constructed in the future.
The system, if constructed as designed, will have no adverse impact on existing
septic systems in the area or those to be constructed in the future.
The system, if constructed as designed, will have no adverse impact on reserve
space, either surface or subsurface, on any lots located in the area.
The system, if constructed as designed, will have no adverse impact on drainage
patterns in the area. The current drainage pattern will be maintained.
Sincerely,
Michael E. Anderson, P.E.
Attachments
14
15
/
/
/
/
/
18
/
/
/
/
16
AREA MAP
SCALE ~.' = 60'
NOTE:
Subdivision is Served by
AWWU Woter System, No
Conflicts with A~ljocent
Wells or Septic Systems.
PUBLIC
WATER
PUBLIC WATER
LEGEND
SV - Septic Vent
CO Cleon Out
MT - Monitor Tube
TH - Test Hole
MH - Mort Hole
15
PUBLIC WATER
16
/
AIterhote
S;te
'2' Long x 5' Wide x 2,5'
Depth Absorpti
Trench.
1,250
Step To~
FCO
pROPOSe-0 HOUSE
G.F.F- ELEV. 365
TH2
®
17
Existing
Well Cosing
Not in Use
-~W~r Serwce ~'~--
~ 49th
PLAN
SCALE 1' = 30'
NOTE:
No ,~reos of Excessive
Slope or Surfo,ce Woter
ore Within 100 of Any
Port of the New Septic
System.
LOT 16, BLOCK1, SCHROEDER EAST SUBDIVISION
DESIGN FACTORS:
Three Bedroom Home
Perc. Rate: 6-15 Min./Inch
Application Rate: .8 GPD/SF
SYSTEM REQUIREMENTS:
5' Wide Trench System
1,250 Gallon STEP Tank
2.5' Drainfield Rock
Pressure Distribution System
3 Bedrooms * 150 GPDIBedroo,m, = 450 SF Abs. orptio_n_A, r._ea_ .
450 SF/.8 GPD/SF/5 SF (Width) .64 (Red. FacTor)= /z Ll-/rencn Length
THEREFORE: Construct a 72' Long x 5' Wide x 2.5' Effective Depth Absorption Trench at the
Location Shown. FIowline Elevation to be 3.5' Below the Existing Ground Elevation. Total Depth to
be 6' Below Existing Ground. Provide 4' of Cover Over Septic Tank and 3' of Cover Over Absorption
Trench. In lieu of Insulation Place 2" of Insulation and 2' of Cover.
_._-.--- Geotextile Fabric
6
~ 1" Perforated
.~ PVC (Holes Down)
30 - 3/16" Holes @ 2.4'
2'6" -- Drainfield Rock
TYPICAL 5' WIDE TRENCH SECTION
(NO SCALE) .,.~
'" :." .,./i-~ "~Y
NOTE: Grade Area Over Trench to Drain Away. ~'~...
Minimum 6' Separation From Bedrock. ~'"-'~'~1""'"'/'"'"'~""'~;'".~'"'~ ~
Minimum 4' Separation From Groundwater. ~..~.v..[~....~..~
Minimum 200' Separation From Class A Well in the Area. ~.~\.M,C,AEL~.^"DE"SON
Minimum 100' Separation From Surface Water or Streams. ~.... No. CE-,3S~
'*4~:...~..-z7-~.~'
A700
MUNICIPALITY OF ANCHORAGE
DEVELOPMENT SERVICES DEPARTMENT
BRAGAW STREET ANCHORAGE, AK ggSIg-6050
SOILS LOG - PERCOLATION TEST
LOT 16, BLOCK (:>, SCHROEDER EAST SUBDIVISION
LEGAL DESCRIPTION:
PERFORMED FOR:
DATE: 5/27/15
PARCEL ID#:
TROY DAVIS HOMES
PROIECT No.:
TECHNICIAN:
DEPTH [ TEST HOLE 1 ]
(feet)
OL/OG SLOPE
1
2
3
4
5
SILTY GRAVEL
6 WITH SAND
GM/SM
?
8
9
11
20¸
BOH @ 12.5'
W. ROBERTS
SITE PLAN
SEE SITE PLAN
WAS GROUND WATER ENCOUNTERED? YES
IFYES~WHATDEPTH? 10.5' ~ [
DEPTH OF WATER AFTER MONITORING: I1' 20/0
DATE OF MONITORING: 5/27/2015 ~
DEPTH TO
DATE ~EADING GROSS TIME NET TIME WATER NET DROF
(MINUTES) (MINUTES) (INCHES) (INCHES)
PERCOLATION RATE: (MIN/1NCH) PERC. HOLE DIA. (INCHES)
TEST RUN BETWEEN: FT. and FT.
COMMENTS: GROUND WATER MONITORING ONLY, TEST HOLE ORIGINALLY COMPLETED BY GARNESS ENGINEERING GROUP,
TEST PERFORMED BY ANDERSON ENGINEERING. I, MICHAEL E. ANDERSON CERTIFY THAT
THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPLE GUIDELINES IN EFFECT ON THIS
DATE: 5/27/15
/ ', \',.;'/ · .Z ' '-,
~ )'- x / --" ~ I( ~PROXIMATE LOCATIO~
~ ' : ': I
~ SERVED BY PUBLIC ,
~ WATER/SEWer J ~ ~ LQT lS BLOCK 1
~
/-- ,- .....
........... .... ........ -...
.
SCHROEDER ~ST, I
LOT 15, BLOCK 1
.......
GARNESS ENGINEERING GROUP, Ltd
'-~ ~': !::::?:' CIVIL & ENVIRONMENTAL ENGINEERS
JUDY HARTLEYI 688-5101 1 Of
SCHROEDER EAST S/D; BLOCK 1, LOT 16 J.1.M.
TYPE OF WORK: DATE: REVISED
SITE PLAN FOR PROPOSED WELL AND SEPTIC SYSTEM 11/3/2014
GARNESS ENGINEERING GROUP, Ltd
CIVIL & .ENVIRONME.NTAL ENGI.NEERS
LEGAL DESCRIPTION: SCHROEDER EAST S/D; BLOCK 1, LOT 16
PERFORMED FOR: JUDY HARTLEY DATE' 8/12/2014
ORGANICS
ITEST HOLE #1 I
SOIL CLASSIFICATIONS
LOAM (SM)
SP TO SH
W/ SOME
GRAVEL
,~ORG
ML
CL
OL
MH
CH
OH
SC
DEPTH TO
GROUNDWATER DATE
1 o' 8/I 212014
10.5' 8/14/2014
10.5' 8120/2014
SITE PLAN
SCALE:
GP TO SP
DATE READING CLOCK NET TIME WATER LEVEL' NET DROP
TIME (MINUTES) READING (INCHES)
8/14/2014 1 2:41 6"
2 3:11 30 3" 3"
3 3:11 6"
4 3:41 30 3.25" 2.75"
5 3:41 6"
6 4:11 30 3.25" 2,75"
I
SOILS LOGGED BY: JODY MAUS
COMMENTS:
.? PERCOLATION RATE 10.9 (HIN,/INCH) PERC. HOLE DIA.
TEST RUN BETWEEN 4.5 FT. AND 5.5 FT,
A FOUR HOUR PRESOAK WAS PERFORHED: · YES [] NO
PERCOLATION TEST PERFORMED BY: JODYMAUS
PERCOLATION READINGS ARE WITHIN 1/16 OF INCH.
6 (tNCHE~
PERFORMED BY GEG, Ltd. I, JEFFREY A. GARNESS, CERTIFY THAT THIS WAS PE~F/DRf,/1ED IN ACCORDANCE
WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE: c~ it..~/t ~
GARNESSENGINEERING GROUP, Lt4
CIVIL & ENVIRONMENTAL ENGINEERS.:.-:
[SOIL LOG - PERCOLATION TEST~
LEGAL DESCRIPTION: SCHROEDER EAST; BLOCK 1, LOT 16
PERFORMED FOR: JUDY HARTLE¥
ORGANICS
ITEST HOLE #2 1
DATE: 08/12/2014
LOAM (SM)
SP TO SM
W/SOME
GRAVEL
GP TO SP
SOIL CLASSIFICATION~S
..~;,>~':' GP ML
GC GL
o SW MH
· SP CH
SM OH
SC
DEPTH TO
GROUNDWATER DATE
8.5' 8/I2/2014
8' 8/14/2014
8' 8/20/2014
SITE PLAN
SCALE:
1"=100'
SOILS LOGGED BY: JODY MAUS
COMMENTS:
DATE READING CLOCK NET TiME WATER LEV
TIME (MINUTES) READING
8114/2014 1 6"
2
3
4
5
6 6 0"
7 6"
8 6 0"
9 6"
10 6 0"
11 6"
12 6 0"
PERCOLATION RATE '1 (MIN./INCH) PERC. HOLE DIA.
TEST RUN BETWEEN 3.5 FT. AND 4.5 FT.
A FOUR HOUR PRESOAK WAS PERFORMED: [] YES · NO
NET
(INCHES)
6"
6"
6 (INCHES)
PERCOLATION TEST PERFORMED BY: JODY MAUS
PERCOLATION READINGS ARE WITHIN 1/16 OF INCH. *PERK DONE IN SP LENSE. RECOMMEND USING TH#2 PERK.
PERFORMED BY GEG, Ltd. I, JEFFREY A. GARNESS, CERTIFY THAT THIS WAS PERFORMED N ACCORDANCE
WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE: