HomeMy WebLinkAboutKYLE AND ERICA LT 7Kyle And Erica
Lot 7
#050-321 -84
Permit Number: OSP151156
Tax Code Number: 05032184000
Work Type: WellSeptic
Permit Effective Dates: June 02, 2015
On-Site Water & Wastewater System Permit
MUNICIPALITY OF ANCHORAGE
Development Services Department
On-Site Water & Wastewater Program
4700 Elmore Road, PO Box 196650
Anchorage, AK 99519-6650
Telephone: (907) 343-7904
Initial
to June 01,2016
Design Engineer: ANDERSON ENGINEERING
Subdivision: KYLE AND ERICA
Site Legal Address: KYLE AND ERICA LT 7 G:0254
Owner/Address: PUTNAM SANDAL
705 BRIDGEPORT DR #1 BISMARCK ND 585040000
Departrnent
Site Mailing Address: 18700 UPPER MC CRARY RD, Eagle River
Lot Size in Sq Ft: 49320
Total Bedrooms: 3
This permit is for the construction of:
Y Disposal Field Y Septic Tank N Holding Tank N Privy Y Private Well N Water Storage
All construction must be in accordance with:
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater
Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80).
3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services
Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either:
A. Open and Close on the same day.
B. Covered, sealed, and heated to prevent freezing.
Received By:
Issued By:
MUNICIPALITY OF ANCHORAGEi
Community Development Department ~ Phone: 9(
Development Services Division ~
On-Site Water & Wastewater Program
JUNoI 2015
Fax: 907~
ON-SITE SEWER/WELL PERMIT APPLICATION
Parcel I.D. 050-321-84
Property owner(s) Troy Davis Homes Day phone 310-2501
Mailing address 165 E. Parks Highway #200 Wasilla, AK 99654
Site address 18700 Upper McCrary Road Eagle River, AK 99577
Legal description (Sub'd., Block & Lot) Kyle and Erica, Lot 7
Legal description (Township, Range & Section)
Lot Size 49,320 Sq. Ft. Number of Bedrooms Three
APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING:
([~ all that apply)
Abso~tion Field ~ !nit!a! [] Single Family (SF) r~
(w/wo ADU)
Septic Tank [] Upgrade []
Duplex (D) []
Holding Tank [] Renewal []
Multiple Dwellings []
Privy [] (SF and/or D)
Private Well []
Water Storage []
THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR:
Distance:
I certify that the above information is correct. I further certify that this is in accordance with
applicable Municipal Codes.
(Signature of property owner or authorized agent)
Permit/Rush Fees:
Date of Payment:
Receipt Number:
Permit No.
la
Waiver Fees:
Date of Payment:
Receipt Number:
Waiver No.
May 30, 2015
Municipality of Anchorage
Development Services Department
On-Site Water and Wastewater Program
4700 South Bragaw Street
Anchorage, AK 99519-6650
Subject:
Lot 7, Kyle and Erica Subdivision
Septic System Design and Permit Application
Impacts to Adjacent Properties
Dear Onsite Services Fngin~c.r'
The owner of Lot 7, Kyle and Erica Subdivision intends to construct a new three-
bedroom home on the lot. We are therefore requesting a permit be issued for the
construction of a new well and septic system to accommodate the home. The attached
Site Plan and backup documentation identify the location and configuration of the
proposed well and septic system along with the alternate site. Also identified on the
plans are the existing wells and septic systems on surrounding lots. No conflicts exist
between the proposed septic system and well or septic systems and wells on adjacent
lots. Drainage arrows and ground surface contours are shown on the site plan showing
the grade and direction of flow on the lot. The drainage pattern will net be changed as
a result of this project.
The test holes recently placed on the lot in the area of the absorption trench and
alternate site indicate sandy gravel with silt (GM/SM). The percolation rate of the soil
was determined to be 4.1-5 minutes per inch. No groundwater was found during the
placement of the test holes and none was noted during the monitoring period. An
application rate of .8 gallons per day per square foot was used in the design of the
absorption system. We are proposing to place a new 1,000-gallon septic tank and a 47'
long by 3' wide by 6' effective depth absorption trench to treat and dispose of the
effluent generated in the house. The elevation of the distribution line in the absorption
trench will be 3' below the surface and the total depth will be 9'. A minimum of 3' of fill
or 2" of insulation and 2' of fill will be placed over the absorption trench and 4' over the
septic tank.
The ground surface on the lot in the area of the septic system slopes to the southwest
at slopes approaching 25%. The new trench will be constructed parallel with the slope
Lot 7, Kyle and Erica Subdivision
May 30, 2015
Page Two
as much as possible in conformance with Municipal requirements. The new septic
system will be constructed a minimum of 100' from all wells and any surface water and
10' the proposed and existing water services in the area.
If the system is constructed in accordance with our design the following statements
apply:
The system, if constructed as designed, will have no adverse impact on the wells
in the area or those to be constructed in the future.
The system, if constructed as designed, will have no adverse impact on existing
septic systems in the area or those to be constructed in the future.
The system, if constructed as designed, will have no adverse impact on reserve
space, either surface or subsurface, on any lots located in the area.
The system, if constructed as designed, will have no adverse impact on drainage
patterns in the area. The current drainage pattern will be maintained.
Sincerely,
Michael E. Anderson, P.E.
Attachments
VACANT ~LOCK 1
I~ '"" ~..,. LOT 1
LOT 7
KYLE AND ERICA
AREA MAP
'**~ e,~ ............
SChLE 1' = 100'
~ ~ ~ ~ --_ ~ ~
~ -- Monitor Tube ~.~.~. ~ '~ ~ ~ ~ ~
TH - Test Home
~.~--~-..-~...~.~.-~.~
~:% No, CE-438~
',i~'....~...'~** o · . ~ m~ ~'~-~-~:~~
LOT 7, KYLE AND ERICA SUBDIVISION
DESIGN FACTORS: SYSTEM REQUIREMENTS:
Three Bedroom Home Deep Trench System
Perc. Rate: 4.1-5 Min./Inch 1.000 Gallon Septic Tank
Application Rate: .8 GPD/SF 6' Drainfield Rock
3 Bedrooms * 150 GPD/Bedroom = 450 SF Absorption Area
450 SF/.8 GPD/SF/12 SF/LF= 46.875 LF Trench Length
THEREFORE: Construct a 47' Long x 3' Wide x 6' Effective Depth Absorption Trench at the
Location Shown on the Site Plan. Flow Line Elevation in the Trench to be 3' Below Existing
Ground. Total Depth to be 9'.Provide 3' of Cover Over Trench and 4' Over Septic Tank.
Maintain 100' Separation from All Wells in the Area.
2'6" ~Geotextile Fabric
6" ~O~ ~ 4" Perforated
PVC (Holes Down)
6'
~ Drainfield Rock
3'
TYPICAL DEEP TRENCH SECTION
(.o SCA,E) .;~ ..........
NOTE: Grade Area Over Trench to Drain Away. f~.
Minimum 6 Separation From Bedrock. ,.....~................~...~....Z~....~/~
Minimum 4' Separation From Groundwater. ...~..~.~_~~
Minimum 100 Separation From Private Wells in the Area. , ~. ~,C~.~..^~D..SO~ ~..
Minimum 100' Separation From Surface Water or Streams. ~.~..'.... ~.
'o;~2.~,.,,z..~.~.."~"'
h-700
[
MUNICIPALITY OF ANCHORAGE
DEVELOPMENT SERVICES DEPARTMENT
BRAGAW STREET ANCHORAGE, AK 99519-6650
LEGAL DESCRIPTION:
PERFORMED FOR:
DATE: t+/18/15
PARCEL ID#:
DEPTH
(feet)
OL
1
2
3
4
5
6--
7--
11
1
SOILS LOG - PERCOLATION TEST ]
LOT 7, KYLE AND ERICA
20¸
SILTY 0RAVEL
GM/SM
BOH @ 15'
TROY DAVIS HOMES, [NC.
PROJECT No.:
TECHNICIAN:
DENALI NORTH
SLOPE
SITE PLAN
SEE SITE PLAN
WAS GROUND WATER ENCOUNl%RED? NO
F YES ~ WHAT DEPTH?__ ,S
DEPTH OF WATER AFTER MONITORING: NONE
DATE OF MONFFOR[NG: 5/15/201§
E
DEPTH TO,INET
WATER
DATE READING GROSS TIME NET TIME
DROP
(MINUTES) (MINUTES)
(INCHES) (INCHES)
TEST HOLE PRESOAKED PRIOR TO TESTING:
4/18 1 11:21 1.1Y'
2 11:51 30 8.50" 7.37"
3 11:52 1.25"
4 12:22 30 8.63" 7.38"
5 12:23 1.13"
6 12:53 30 8.50" 7.37"
PERCOLATION RATE: 4.1 .(MIN/1NCH) PERC. HOLE DIA. 6" _(INCHES)
TEST RUN BETWEEN: 4.0 FT. and 5.0 FT.
COMMENTS: TEST HOLE PRE SOAKED PRIOR TO TEST.
TEST PERFORMED BY ANDERSON ENGINEERING. I, MICHAEL E. ANDERSON CERTIFY THAT
THIS WAS PERFORMED 1N ACCORDANCE WITH ALL STATE AND MUNICIPLE GUIDELINES IN EFFECT ON THIS
DATE: 5/2/~/15
4700
[
DEPTH
1
2
3
4
5
6
7
8
9
11
I~IUNICIPALITY OF ANCHORAGE
DEVELOPMENT SERVICES DEPARTMENT
BRAGAW STREET ANCHORAGE, AK 99519-6650
1
SOILS LOG - PERCOLATION TEST J
LOT 7, KYLE AND ERICA
LEGAL DESCRIPTION:
PERFORMED FOR:
DATE: 4/[8/[~
PARCEL ID#:
TROY DAVIS HOHES. INC.
PROJECT No.:
TECHNICIAN:
0L
SILTY GRAVEL
GM/SM
WAS GROUND WATER ENCOUNTERED?
IF YES ~ WHAT DEPTH?
DEPTH OF WATER AFTER MON]TOPdNG:
DATE OF MONITORING: 5/[5/2015
BOH @
DENALI NORTH
SLOPE
No
SITE PLAN
SEE SITE PLAN
DEPTH TO
DATE READING GROSS TIHE NET TIME WATER NET DROP
(MINUTES) (MINUTES) (INCHES) (INCHES)
TEST HOLE PRESOAKED PRIOR TO TESTING:
4/18 ] 11:]5 2.25"
2 11:45 30 8.25"'! 6.00"
3 11:46 2.25"
4 12:16 30 8.25" 6.00"
5 12:17 2.13"
6 12:47 30 8.13" 6.00"
PERCOLATION RATE: 5.0.(M1N/1NCH) PERC. HOLE DIA. 6" (INCHES)
TEST RUN BETWEEN: 4.0 FT. and 5.0 FT.
COMMENTS: TEST HOLE PRE SOAKED PRIOR TO TEST.
TEST PERFORMED BY ANDERSON ENGINEERING. I, MICHAEL E. ANDERSON CERTIFY THAT
THIS WAS PERFORMED ln ACCORDANCE WITH ALL STATE AND MUNICIPLE GUIDELINES IN EFFECT ON THIS
DATE: 5124115