Loading...
HomeMy WebLinkAboutKYLE AND ERICA LT 7Kyle And Erica Lot 7 #050-321 -84 Permit Number: OSP151156 Tax Code Number: 05032184000 Work Type: WellSeptic Permit Effective Dates: June 02, 2015 On-Site Water & Wastewater System Permit MUNICIPALITY OF ANCHORAGE Development Services Department On-Site Water & Wastewater Program 4700 Elmore Road, PO Box 196650 Anchorage, AK 99519-6650 Telephone: (907) 343-7904 Initial to June 01,2016 Design Engineer: ANDERSON ENGINEERING Subdivision: KYLE AND ERICA Site Legal Address: KYLE AND ERICA LT 7 G:0254 Owner/Address: PUTNAM SANDAL 705 BRIDGEPORT DR #1 BISMARCK ND 585040000 Departrnent Site Mailing Address: 18700 UPPER MC CRARY RD, Eagle River Lot Size in Sq Ft: 49320 Total Bedrooms: 3 This permit is for the construction of: Y Disposal Field Y Septic Tank N Holding Tank N Privy Y Private Well N Water Storage All construction must be in accordance with: 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80). 3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either: A. Open and Close on the same day. B. Covered, sealed, and heated to prevent freezing. Received By: Issued By: MUNICIPALITY OF ANCHORAGEi Community Development Department ~ Phone: 9( Development Services Division ~ On-Site Water & Wastewater Program JUNoI 2015 Fax: 907~ ON-SITE SEWER/WELL PERMIT APPLICATION Parcel I.D. 050-321-84 Property owner(s) Troy Davis Homes Day phone 310-2501 Mailing address 165 E. Parks Highway #200 Wasilla, AK 99654 Site address 18700 Upper McCrary Road Eagle River, AK 99577 Legal description (Sub'd., Block & Lot) Kyle and Erica, Lot 7 Legal description (Township, Range & Section) Lot Size 49,320 Sq. Ft. Number of Bedrooms Three APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: ([~ all that apply) Abso~tion Field ~ !nit!a! [] Single Family (SF) r~ (w/wo ADU) Septic Tank [] Upgrade [] Duplex (D) [] Holding Tank [] Renewal [] Multiple Dwellings [] Privy [] (SF and/or D) Private Well [] Water Storage [] THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit/Rush Fees: Date of Payment: Receipt Number: Permit No. la Waiver Fees: Date of Payment: Receipt Number: Waiver No. May 30, 2015 Municipality of Anchorage Development Services Department On-Site Water and Wastewater Program 4700 South Bragaw Street Anchorage, AK 99519-6650 Subject: Lot 7, Kyle and Erica Subdivision Septic System Design and Permit Application Impacts to Adjacent Properties Dear Onsite Services Fngin~c.r' The owner of Lot 7, Kyle and Erica Subdivision intends to construct a new three- bedroom home on the lot. We are therefore requesting a permit be issued for the construction of a new well and septic system to accommodate the home. The attached Site Plan and backup documentation identify the location and configuration of the proposed well and septic system along with the alternate site. Also identified on the plans are the existing wells and septic systems on surrounding lots. No conflicts exist between the proposed septic system and well or septic systems and wells on adjacent lots. Drainage arrows and ground surface contours are shown on the site plan showing the grade and direction of flow on the lot. The drainage pattern will net be changed as a result of this project. The test holes recently placed on the lot in the area of the absorption trench and alternate site indicate sandy gravel with silt (GM/SM). The percolation rate of the soil was determined to be 4.1-5 minutes per inch. No groundwater was found during the placement of the test holes and none was noted during the monitoring period. An application rate of .8 gallons per day per square foot was used in the design of the absorption system. We are proposing to place a new 1,000-gallon septic tank and a 47' long by 3' wide by 6' effective depth absorption trench to treat and dispose of the effluent generated in the house. The elevation of the distribution line in the absorption trench will be 3' below the surface and the total depth will be 9'. A minimum of 3' of fill or 2" of insulation and 2' of fill will be placed over the absorption trench and 4' over the septic tank. The ground surface on the lot in the area of the septic system slopes to the southwest at slopes approaching 25%. The new trench will be constructed parallel with the slope Lot 7, Kyle and Erica Subdivision May 30, 2015 Page Two as much as possible in conformance with Municipal requirements. The new septic system will be constructed a minimum of 100' from all wells and any surface water and 10' the proposed and existing water services in the area. If the system is constructed in accordance with our design the following statements apply: The system, if constructed as designed, will have no adverse impact on the wells in the area or those to be constructed in the future. The system, if constructed as designed, will have no adverse impact on existing septic systems in the area or those to be constructed in the future. The system, if constructed as designed, will have no adverse impact on reserve space, either surface or subsurface, on any lots located in the area. The system, if constructed as designed, will have no adverse impact on drainage patterns in the area. The current drainage pattern will be maintained. Sincerely, Michael E. Anderson, P.E. Attachments VACANT ~LOCK 1 I~ '"" ~..,. LOT 1 LOT 7 KYLE AND ERICA AREA MAP '**~ e,~ ............ SChLE 1' = 100' ~ ~ ~ ~ --_ ~ ~ ~ -- Monitor Tube ~.~.~. ~ '~ ~ ~ ~ ~ TH - Test Home ~.~--~-..-~...~.~.-~.~ ~:% No, CE-438~ ',i~'....~...'~** o · . ~ m~ ~'~-~-~:~~ LOT 7, KYLE AND ERICA SUBDIVISION DESIGN FACTORS: SYSTEM REQUIREMENTS: Three Bedroom Home Deep Trench System Perc. Rate: 4.1-5 Min./Inch 1.000 Gallon Septic Tank Application Rate: .8 GPD/SF 6' Drainfield Rock 3 Bedrooms * 150 GPD/Bedroom = 450 SF Absorption Area 450 SF/.8 GPD/SF/12 SF/LF= 46.875 LF Trench Length THEREFORE: Construct a 47' Long x 3' Wide x 6' Effective Depth Absorption Trench at the Location Shown on the Site Plan. Flow Line Elevation in the Trench to be 3' Below Existing Ground. Total Depth to be 9'.Provide 3' of Cover Over Trench and 4' Over Septic Tank. Maintain 100' Separation from All Wells in the Area. 2'6" ~Geotextile Fabric 6" ~O~ ~ 4" Perforated PVC (Holes Down) 6' ~ Drainfield Rock 3' TYPICAL DEEP TRENCH SECTION (.o SCA,E) .;~ .......... NOTE: Grade Area Over Trench to Drain Away. f~. Minimum 6 Separation From Bedrock. ,.....~................~...~....Z~....~/~ Minimum 4' Separation From Groundwater. ...~..~.~_~~ Minimum 100 Separation From Private Wells in the Area. , ~. ~,C~.~..^~D..SO~ ~.. Minimum 100' Separation From Surface Water or Streams. ~.~..'.... ~. 'o;~2.~,.,,z..~.~.."~"' h-700 [ MUNICIPALITY OF ANCHORAGE DEVELOPMENT SERVICES DEPARTMENT BRAGAW STREET ANCHORAGE, AK 99519-6650 LEGAL DESCRIPTION: PERFORMED FOR: DATE: t+/18/15 PARCEL ID#: DEPTH (feet) OL 1 2 3 4 5 6-- 7-- 11 1 SOILS LOG - PERCOLATION TEST ] LOT 7, KYLE AND ERICA 20¸ SILTY 0RAVEL GM/SM BOH @ 15' TROY DAVIS HOMES, [NC. PROJECT No.: TECHNICIAN: DENALI NORTH SLOPE SITE PLAN SEE SITE PLAN WAS GROUND WATER ENCOUNl%RED? NO F YES ~ WHAT DEPTH?__ ,S DEPTH OF WATER AFTER MONITORING: NONE DATE OF MONFFOR[NG: 5/15/201§ E DEPTH TO,INET WATER DATE READING GROSS TIME NET TIME DROP (MINUTES) (MINUTES) (INCHES) (INCHES) TEST HOLE PRESOAKED PRIOR TO TESTING: 4/18 1 11:21 1.1Y' 2 11:51 30 8.50" 7.37" 3 11:52 1.25" 4 12:22 30 8.63" 7.38" 5 12:23 1.13" 6 12:53 30 8.50" 7.37" PERCOLATION RATE: 4.1 .(MIN/1NCH) PERC. HOLE DIA. 6" _(INCHES) TEST RUN BETWEEN: 4.0 FT. and 5.0 FT. COMMENTS: TEST HOLE PRE SOAKED PRIOR TO TEST. TEST PERFORMED BY ANDERSON ENGINEERING. I, MICHAEL E. ANDERSON CERTIFY THAT THIS WAS PERFORMED 1N ACCORDANCE WITH ALL STATE AND MUNICIPLE GUIDELINES IN EFFECT ON THIS DATE: 5/2/~/15 4700 [ DEPTH 1 2 3 4 5 6 7 8 9 11 I~IUNICIPALITY OF ANCHORAGE DEVELOPMENT SERVICES DEPARTMENT BRAGAW STREET ANCHORAGE, AK 99519-6650 1 SOILS LOG - PERCOLATION TEST J LOT 7, KYLE AND ERICA LEGAL DESCRIPTION: PERFORMED FOR: DATE: 4/[8/[~ PARCEL ID#: TROY DAVIS HOHES. INC. PROJECT No.: TECHNICIAN: 0L SILTY GRAVEL GM/SM WAS GROUND WATER ENCOUNTERED? IF YES ~ WHAT DEPTH? DEPTH OF WATER AFTER MON]TOPdNG: DATE OF MONITORING: 5/[5/2015 BOH @ DENALI NORTH SLOPE No SITE PLAN SEE SITE PLAN DEPTH TO DATE READING GROSS TIHE NET TIME WATER NET DROP (MINUTES) (MINUTES) (INCHES) (INCHES) TEST HOLE PRESOAKED PRIOR TO TESTING: 4/18 ] 11:]5 2.25" 2 11:45 30 8.25"'! 6.00" 3 11:46 2.25" 4 12:16 30 8.25" 6.00" 5 12:17 2.13" 6 12:47 30 8.13" 6.00" PERCOLATION RATE: 5.0.(M1N/1NCH) PERC. HOLE DIA. 6" (INCHES) TEST RUN BETWEEN: 4.0 FT. and 5.0 FT. COMMENTS: TEST HOLE PRE SOAKED PRIOR TO TEST. TEST PERFORMED BY ANDERSON ENGINEERING. I, MICHAEL E. ANDERSON CERTIFY THAT THIS WAS PERFORMED ln ACCORDANCE WITH ALL STATE AND MUNICIPLE GUIDELINES IN EFFECT ON THIS DATE: 5124115