TIMBERLANE PARK #1 BLK 4 LT 7A
Timb rlone Park Block 4 Lot 7A #019-152-47 Permit Number: Tax Code Number: Work Type: On-Site Wastewater DisposaJ System Permit OSP151143 01915247000 Septic MUNICIPALITY OF ANCHORAGE Development Services Department On-Site Water & Wastewater Program 4700 Elmore Road, PO Box 196650 Anchorage, AK 99519-6650 Telephone: (907) 343~7904 Upgrade Permit Effective Dates: June 16, 2015 to June 15, 2016 Design Engineer: ANDERSON ENGINEERING Subdivision: TIMBERLANE PARK #1 Site LegalAddress: TIMBERLANE PARK#1 BLK 4 LT 7A G:2729 Owner/Address: FERNANDEZ FEDERICO 12140 HILLTOP DRIVE ANCHORAGE AK 995150000 Department Site Mailing Address: 12140 HILLTOP DR, Anchorage Lot Size in Sq Ft: 40223 Total Bedrooms: 4 This permit is for the construction of: Y Disposal Field Y SepticTank N Holding Tank N Privy N Private Well N Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80). 3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either: A. Qpen and Close on the same day. B. Covered, sealed, and heated to prevent freezing. Municipality of Anchorage P.O. Box 196650 · 4700 Elmore Road Anchoraae. A~aska 99519-6650 · (907) 343-7904 · Fax {907) 343-7997 httr):llwww.muni.o~lOnsite Development Services Division On-Site Water and Wastewater Proqram **** VARIANCE/WAIVER REVIEW **** WaiverS: OSV151062 COSA#: Permit~: OSP151143 PID~: 019-152-47 Legal Description: Timberlane Park #1 Block 4 Lot 7A Engineer: Anderson Enclineerina Applicant: Feder/co,Furnandez Your request for a waiver of the required 50 feet horizontal separation from the absorption field to the excessive slope has been approved. The approved separation distance is 15'.0 feet. This waiver approval applies to the proposed absorption field only. Any future upgrade to the on-site wastewater disposal system will require all separation distances be met or another approval from this department. [] The affected adjacent property owner(s) have been given a 7 day notice regarding this waiver. [] Notarized letter(s) of nonobjection have been received from the owner(s) of the affected adjacent property. [] Adjaeenl properties are not affected by this waiver. Waiver is Granted: X Waiver is not Granted: , ! ' Name of Re-vie. w~r; **** VARIANCE/WAIVER REVIEW **** MUNICIPALITY OF ANCHORAGE Community Development Department Development Services Division On-Site Water & Wastewater Program Phone: 907-343-7904 Fax: 907-343-7997 ON-SITE SEWEPJVVELL PERMIT APPLICATION Parcel I.D. 019-152-47 Property owner(s) Federico Fernandez Mailing address 12140 Hilltop Drive Anchorage, AK 99515 Day phone Site address Same Legal description (Sub'd., Block & Lot) Timberlane Park #1, Block 4, Lot 7A Legal description (Township, Range & Section) Lot Size 40,223 Sq. Ft. Number of Bedrooms Four (4) APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: ([~ all that apply) Absorption Field [] Initial [] Single Family (SF) [] (w~vo ADU) Septic Tank [] Upgrade [] Duplex (D) [] Holding Tank [] Renewal [] Multiple Dwellings [] Privy [] (SF and/or D) Private Well [] Water Storage [] THIS APPLICATION INCLUDES A VARIANCE I WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit/Rush Fees: Date of Payment: Receipt Number: Permit No. O~2~1 Waiver Fees: -~ ~-/.~ Date of Payment: Receipt Number: Permit App_9-1-12.doc ANDERSON ENGINEERING P.O. BOX 240773 ANCHORAGE, AK 99524 522-7773 677-7766 (FAX) May 24, 2015 Municipality of Anchorage Development Services Department On-Site Water and Wastewater Program 4700 Elmore Road Anchorage, AK 99519-6650 Subject: Lot 7A, Block 4, Timberlane Park Subdivision No. 1 Septic System Design and Permit Application Impacts to Adjacent Properties Dear Onsite Services Engineer: The absorption system on the subject lot has failed and must be replaced prior to the issuance of a COSA. We are therefore requesting a permit be issued for the upgrade of the septic system to accommodate the four-bedroom home on the lot. The attached Site Plan and backup documentation identify the location and configuration of the existing and proposed septic system. The existing Septic Tank will be uncovered, inspected and verified suitable for continued use. A new tank will be placed if required and the existing tank decommissioned in accordance with Municipal Code. The existing absorption pit and trench will be decommissioned in accordance with Municipal Code. Also identified on the plans are the locations of the existing water service on this lot and adjacent septic systems. The subdivision is served by the AWWU water system. No conflicts exist between the proposed septic system and the wells or water services on this or adjacent lots. Drainage arrows are shown indicating the current drainage patterns. The ground surface in the area of the proposed trench is virtually flat. The drainage patterns will be maintained after construction. The test hole placed on the lot indicated Silty Gravel with Sand (GM/SM) in the absorption zone of the trench. The percolation rate was determined to be between 6 and 15 minutes per inch. No groundwater was encountered during the placement of the test hole and none has developed to date. We have designed the new trench with an application rate of .8 gallons per day per square foot. We are proposing to place a 50' long trench by 3' wide with an 8' effective depth. The total depth of the system will be 11.5' with the distribution line at 3.5' below the existing surface, change order will be drafted and submitted for approval. Lot 7A, Block 4, Timberlane Park #1 May 24, 2015 Page Two The ground surface on.the lot in the area of the new trench is flat. The trench will be placed parallel to the contours of the ground as much as possible and in conformance with design criteria. A minimum of 100' will be maintained between all components of the septic system and the proposed well and from any surface water in the area. If the system is constructed in accordance with our design the following statements apply: The system, if constructed as designed, will have no adverse impact on the wells in the area or those to be constructed in the future. The system, if constructed as designed, will have no adverse impact on existing septic systems in the area or those to be constructed in the future. The system, if constructed as designed, will have no adverse impact on reserve space, either surface or subsurface, on any lots located in the area. The system, if constructed as designed, will have no adverse impact on drainage patterns in the area. The current drainage pattern will be maintained. Sincerely, Michael E. Anderson, P.E. Attachments TIMBERLANE PARK SUBDIVISION # 1 l' 40,223 S.F. PUBLIC WATER Area NOTE~ Decommission Existing Absorption LEGEND ~ ~~/~//~~ PUBLIC FOO- Foundation Clean Out TH - Test Hole ~~~ CO - Clean Out MH - Man Hole ~ ~ CONTOUR INTERVAL - 2' ~ ~ NO, C[-430I ~ Area , . LOT 7A, BLOCK 4, TIMBERLANE PARK SUBDIVISION #1 DESIGN FACTORS: SYSTEM REQUIREMENTS: Four Bedroom Home Deep Trench System Perc. Rate: 12 Min./Inch Vedfy Existing 1,250 Gallon Septic Tank Application Rate: .8 GPD/SF 8' Drainfield Rock 4 Bedrooms X 150 GPD/.8 GPD/SF (Application Rate) = 750 SF Absorption Area 750 SF/16 SF/LF = 46.875 LF Trench Length THEREFORE: Construct a 50' Long x 3' Wide x 8' Effective Depth Absorption Trench at the Location Shown. Flow Line Elevation in Trench to be 3.5' Below the Original Ground Surface. Total Depth to be 11.5' Below Exisitng Ground. Veri~ the Integrity of the Existing 1,250 Gallon Concrete Septic Tank. Replace Baffle if Necessary. Decommission Existing Tank in Accordance with Municipal Code if Required. Place 4' of Cover Over Tank and 3' of Cover Over Trench. Maintain 100' Separation From All Private Wells in the Area and 10' from All Water Service Connections. Natural Backfill Geotextile Fabric 4" Perforated PVC (Holes Down) Drainfield Rock TYPICAL DEEP TRENCH SECTION Nosc^,E ........... NOTE: Grade Are.a, Over Trench to Drain Away. f.~.-..c?' 49th Minimum 6 Separation From Bedrock ,,'.....~.,.......,.,.,.., ........... ,,~.....~ Minimum 4' Separation From Groundwater. ~~ Minimum 100 Separation From Wells in the Area. ~.~ .............. ~,c~^~",~'~",'~;~"?~ ' Minimum 100' Separation From Surface Water or Streams- ~:~ ". No 4700 DEPTH (~e0 1 2 3 4 5 6 7 8 9 11 20- MUNICIPALITY OF ANCHORAGE DEVELOPHENT SERVICES DEPARTHENT BRAGAW STREET ANCHORAGE, AK 99519-6650 SOILS LOG - PERCOLATION TEST LEGAL DESCRIPTION: PERFORMED FOR: DATE: 4/1&/2015 PARCEL ID#: LOT 7A, BLOCK L~, TIMBERLANE PARK SUB. CPI FEDERICO FERNANDEZ PROJECT No.: TECHNICIAN: OS/OG SILTY GRAVEL WITH SAND GM/SM WAS GROUND WATER ENCOUNTERED? __ IF YES ~ WHAT DEPTH? DEPTH OF WATER AFTER MONITORING: BOH @ 18' HEA SLOPE NO SITE PLAN SEE SITE PLAN DATE OF MON]TORING' 5/15/15 E O% DEPTH 70 DATE READING GROSS TIME NET TIME WATER NET DROP (MINUTES) (MINUTES) (INCHES) (INCHES) TEST HOLE PRESOAKED PRIOR TO TESTING: 4/16 1 1:13 1.25" 2 1:43 30 3.75" 2.50" 3 1:45 1.38" 4 2:15 30 3.63" 2.50" 5 2:16 1.25" 6 2:46 30 3.75" 2.50" PERCOLATION RATE: 12 (NlM/INCH) PERC. HOLE DIA. 6" (INCHES) TEST RUN BETWEEN.'. 3.0 FT. and 4.0 FT. COMMENTS: TEST HOLE PRE SOAKED PRIOR TO TEST. TEST PERFORMED BY ANDERSON ENGINEERING. I, MICHAEL E. ANDERSON CERTIFY THAT THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPLE GUIDELINES IN EFFECT ON THIS DATE: 5/24/2015 June 14, 2015 Municipality of Anchorage Development Services Department On-Site Water and Wastewater Program 4700 South Bragaw Street Anchorage, AK 99519-6650 Subject: Timberlane Park No. 1, Block 4, Lot 7A Proposed Lot 1, Star Route A Subdivision Absorption Trench to Slope Waiver Dear Onsite Services Engineer: The location for the new absorption trench on the subject lot is relatively flat. The slope steepens to slightly more than 25% approximately 15' from the northeast end. We are therefore applying for a waiver allowing placement of the absorption trench at the location shown. The existing absorption trench on the lot has failed. It is much closer to the slope greater than 25% and no evidence of bleeding out of the slope is evident. The attached drawing shows the absorption trench in relation to the slope. The imaginary 25% slope when extended downward from 2.5' above the flow line invert does not daylight. We therefore recommend a waiver be issued allowing placement of the new absorption trench within 15' of a slope greater than 25%. Sincerely, Michael E. Anderson, P.E. ~ · 49[h ~'~, ~'.~ '. No. CE 4~8~ O~ (~ z r'nO 0 0 0 )n Trench Municipality of Anchorage V PGE On -Site Water and Wastewater Program (907),343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL Parcel I.D. 019-152-47 _ Expiration Date: 1. GENERAL INFORMATION Complete legal description Timberlane Park #1 Block 4 Lot 7A Location (site address) 12140 Hilltop Dr. Anchorage, AK 99515__..__ Current Property owner(s) Michael Niebur Day phone ______________ Mailing address Real Estate Agent 12140 Hilltop Dr. Anchorage, AK 99515 2. TYPE OF DWELLING: ® Single Family (w/wo ADU) ❑ Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) Day phone 3. NUMBER OF BEDROOMS: 4 TYPE OF WASTEWATER DISPOSAL: 4. TYPE OF WATER SUPPLY: Individual Individual Well ❑ Holding Tank ❑ Individual Water Storage ❑ Community ❑ Community Class _Well ❑ Public Sewer ❑ Public Water System Waiver/Variance request for: Distance: Received by: Date: COSA to be released to the engineer, unless otherwise requested by the engineer. COSA Fee $ 55 0 Date of Payment _ i�.0• j _ Receipt Number 0 5 9 G COSA # O S C;211 5 6 6. Waiver Fee $ Date of Payment Receipt Number Waiver # 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm ARCTERRA CONSULTING, INC. Phone 696-6111 Address 20441 PTARMIGAN BLVD EAGLE RIVER AK. _99577 Engineer's Printed Name _KENNETH M. DUFFUS Date g <7�L Engineer's Comments: This investigation was completed in compliance with ADEC and MOA regulations. The assessment of the condition of the well and septic applies only to the conditions as of the day tested. The flow and absorption rates may change due to subsurface conditions that may not be observed from the surface, changes inland use, local soil characteristics, groundwater levels that may fluctuate during the year and the water usage of the family being served by the system. The operational life of all well and septic systems are subject to these various and dynamic characteristics and are outside the control of the evaluator of the well and septic system. Therefore, ArcTerra can not give any estimate of how long a system will function satisfactory for current or future +��\ occupants or can ArcTerra guarantee that no unseen•^ OF - 1 \ encroachments, deficiencies or discrepancies exist. /�t�N. 1 6. DSD SIGNATURE System #1 Approved for. bedrooms. System #2 Approved for Disapproved. Conditional approval for bedrooms. bedrooms, with the J� �� ON-SITE_ - ------ --- -` INATFR AND---- =rT,1 WAcrr: , fAT-- PROGf,AM 1 Original Certificate Date:. - 10_- The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: COSA Checklist Septic System Advisory Well Flow Advisory COSA blue sheet -10-10-12 doc X Nitrate Advisory Arsenic Advisory Other Legal Description: Timberlane Park #1 Block 4 Lot 7A If more than 1 septic system on lot: COSA Checklist # of WELL DATA ❑ Well iled with Onsite (or attached) Date drilled Total depth ft Cased to ft ❑ Sanitary seal is functioning correctly ❑ Wires are properly protected Casing height (above ground) in. Date of flow test for COSA Static water level at beginning of test ft. Comments B. TANK DATA Age of tank(s) 6 years Tank type/materialSep tic/Steel Measured operating fluid level in septic tank 49" Standpipes/foundation cleanout per record drawing Date of pumping 9/23/21 D. ABSORPTION FIELD DATA Which system tested (date installed) 6/22/15 ALL standpipes present per record drawing Total measured depth from grade 12 ft (max) Measured depth to pipe invert from grade 4 ft (min) ❑ N/A — pressurized field IN Monitor tubes go to bottom of effective. If not, state depth into effective Code -required soil cover over field ❑ System presoaked (Required if vacant for greater than 30 days prior to date of test) Gallons introduced gallons Comments/Deficiencies: COSA Checklist yellow sheet Parcel ID: 019-152-47 Structure served by this system Well production at time of test gpm Water storage tank volume gallons Well disinfected for coliform test? ❑ Yes ❑ No ❑ Coliform bacteria is Negative Nitrate mg/L ❑ Nitrate less than MRL (ND) ug/L ❑ Arsenic less than MRL (ND) Collected Date of Sample STATION ❑ Requl aintenance completed Age of lift station years Lift station material Comments: Adequacy test date 9/15/21 Results Q Pass For 4 bedrooms Fluid depth prior to test 40 in Water added 600 gal New depth 45 in Elapsed time 1440 min Final fluid depth 40 in Absorption rate 600+ gpd Any rejuvenation treatment (past 12 months) If yes, enter date E. SEPARATION DISTANCES FtsQkFr Well on Lot to: (Please enter distances if less than required or if community well) Septic Tank/Lift n Lot > 100' if No 5+* ft Community Sewer Manhole/Cleanout > 100' Yes if No ft ❑ Yes if No ft Neighboring Tank > 100' ❑ Yes if _ ft Private Sewer/Septic Line > 25' ❑ Yes if No ft Absorption Field on Lot > 100' ❑ Yes if No ft Tank >100' ❑ Yes if No ft Neighboring Absorption Fields > 100' Water Main > 10' ® Yes Animal Contain 50' ❑ Yes if No ft ❑ Yes if No ft Water Service Line > 10' ® Yes if No ft Manure/Animal Excreta Storage > Community Sewer Main > 75' ❑ Yes if No ft ❑ Yes i ft From Septic/Holding Tank on Lot to: (Please enter distances if less than required) Building Foundations > 10' ❑ Yes if No 5+* ft Surface Water > 100' ® Yes if No ft Property Line > 5' ® Yes if No ft Wells on Adjacent Lots: ft Community Wells > 200' Absorption Field > 5' ® Yes if No ft Private Wells > 100' ® Yes if No ft Water Main > 10' ® Yes if No ft Community Wells > 200' ® Yes if No ft Water Service Line > 10' ® Yes if No ft If septic tank is under driveway comment below From Absorption Field on Lot to: (Please enter distances if less than required) Building Foundation > 10' 0 Yes if No ft If absorption field is under driveway comment below Property Line > 10' ® Yes if No ft Wells on Adjacent Lots: Water Main > 10' ® Yes if No ft Private Wells > 100' Water Service Line > 10' ® Yes if No ft Community Wells > 200' Surface Water > 100' ® Yes if No ft F. ENGINEER'S COMMENTS *Meet code at time of construction. G. ENGINEER'S CERTIFICATION l certify that I have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this date. COSA Checklist yellow sheet ® Yes if No ft ® Yes if No ft CE "S MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION ENVIRONMENTAL ENGINEERING DIVISION 825 L Street- Anchorage, Alaska 99501 Telephone 264-4720 ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT PHONE [] NEW .. J~ UPGRADE MAILING ADBRESS ~ Z Manufscturer ~ /Z~Sr ~ X ~ Mater~r~ NO. of compartmenj~, ~'~ Liq. ce~t~allons IF HOME,DE: Inside length Width Liquid depth ~ ~ Well Dwelling PER~IT 0 Z ~ ~anufacturer Material Liquid capscJty in gallons Q Well -- N°'°flines ~ inches Totai effecti~e~u~area Length ~idth Depth PERMIT NO. ~ N Type of crib Crib diameter Crib depth Total effective absorption area ~ Well Building foundation Nearest lot line ~ DISTANCE TO: ~ Class Depth Driller Distance to lot llne PERMIT NO. ~ Building foundatlo~ Sewer lin~ Septic tank Absorption area(s) ~ DISTANCE TO: OTHER PIPE M~ERIAL8 [ ¢ 0 APPROVED '~ DATE LEGAL PERMIT NO. APPLICANT LOCATION LEGAL LLOYD E. FLADOARD 1010 HILLTOP DR L? B4 TIMBERLANE 1' C I PAL_ ! TY OF ~:t~413:HLI~RI~I-]E DEPRRTMEN~ OF HEALTH ~N~ ENYIRONMENTBL PROTECTION 825 ~L~ STREET.. ANCHORAGE., AK. 9~501 2~4-~72B · ~1 ~/~- 1 / i~4 SPRUCE ST (WA. > ~'~ 2~ i541 LOT SIZE 80000 SQUARE FEET TYPE OF SOIL RBSORBTION SYSTEM IS: TRENCH MAXIMUM/NUMBER OF BEDROOMS = 4 SOIL RATING _,Y~TEM THE REQUIRED SIZE OF THE SOIL ABSORPTION ~ ~ IS: <m~. FT/BR): ~ [~EPTH=: [:,EPTH: ::LB LE~GTH= THE LENGTH DIMENSION IS THE LENGTH (IN FEET) OF THE TRENCH OR DRAINFIELD. THE DEPTH OF A TRENCH OR PIT IS THE DISTANCE BETWEEN THE SURFACE OF THE GROUND AND THE BOTTOM OF THE EXCAVATION (IN FEET). THERE IS NO SET WIDTH FOR TRENCHES. THE GRAVEL DEPTH IS THE MINIMUM DEPTH OF ORAVEL 8ETWEEN THE OUTF~LL PIPE AND THE BOTTOM OF THE EXCAVATION (IN FEET). PERMIT APPLICANT HAS THE RESPONSIBILITY TO INFORM THIS DEPARTMENT DURING THE INSTALLATION INSPECTIONS OF ANY WELLS ADJACENT TO THIS PROPERTY AND THE NUMBER OF RESIDENCES THAT THE WELL WILL SERVE. T~,IO (2) I NSPEC:TIO~$ ARE BACKFILLING OF ANY SYSTEM WITHOUT FINAL INSPECTION AND APPROVAL BY THIS DEPARTMENT WILL BE SUBJECT TO PROSECUTION. MINIMUM DISTANCE BETWEEN A WELL AND ANY ON-SITE SEWRGE DISPOSAL SYSTEM IS 100 FEET FOR R PRIVATE WELL~ OR 150 TO 200 FEET FROM A PUBLIC WELL DEPENDING UPON THE TYPE OF PUBLIC WELL. OTHER REQUIREMENTS MAY APPLY. SPECIFICATIONS AND CONSTRUCTION DIAGRAMS ARE AVAILABLE TO INSURE PROPER INSTALLATION. I CERTIFY THAT 1: I AM FAMILIAR WITH THE REQUIREMENTS FOR ON-SITE -~EWER_ AND WELLS A--. SET FORTH BY THE MUNICIPALITY OF ANCHORAGE. 2' I WILL INSTALL THE SYSTEM IN 8[.GORDBN..E WITH THE CODES. .~: I UNDERSTAND THAT THE ON-SITE SEWER SYSTEM MAY REQUIRE ENLARGEMENT IF TH~ RESIDENCE IS REMODELED TO INCLUDE MORE THAN 4 BEDROOMS. ........ ......... APPLICANT ~OYD E. FLRDGRR[~ ISSUE~ BY ..... DBTE_ - V~. 2 December 27, 1978 H&MNo. 851159 ~oyd Fladgard c/o Polar Realty International Airport Rd. Anchorage, Alaska Subject: Soil Investigation for Sanitary Sewer System, Lot 7, Block Timberlane Subdivision, Anchorage, Alaska Dear Mr. Fladgard: At your request of December 26, 1978, we conducted a subsurface soils inves- tigation at the proposed location of the sanitary sewer system on the subject lot. The investigation complied with those procedures required by the Municipality of Anchorage Department of Health and Enviromnental Protection. This investigation, which was accomplished on December 27, 1978, consisted of a test hole drilled to a depth of 20 feet below the existing ground surface. The test hole was sited according to your instructions and its location is shown in attached Drawing A-O]. Drilling was accomplished with a rotary drill rig using continuous flight solid-stem with an outside diameter of 5 inches. A sample was taken taken at the depths shown on the soils log in Drawing A-01. The sample will be held in storage at our lab for approxi- mately six months. In addition, all material brought to the surface by the angers was continuously monitored by an experienced engineering geologist. The topography at the drilling site is generally horizontal. At the time of the investigation the site had been stripped. The top of the test hole was located at original ground surface. The soils encountered in the bore hole are shown in the test hole log in Drawing A-01. This log displays specific conditions encountered at the test location. However, subsurface conditions may vary in other parts of the lot without any apparent surficiat evidence of the change. Groundwater was not encountered and bedrock was not encountered. At the time the hole was drilled seasonal frost was present from the surface to a depth of 3 inches and permafrost was not encountered. A percolation test was performed within the bore hole at the depth shown in the attached Table 1. All depths were measured from the top of the hole. The data in Table 1 show average infiltration from the depths indicated to the bottom of the hole. The measured percolation rate was 3.3 minutes per inch. December 27, 1978 Loyd Fladgard c/o Polar Realty Page -2- We appreciated this opporto~nity to be of service to you. Please contact us if you have any questions concerning this letter or if we can be of addi- tional service. Very truly yours, R&M CONSULTANTS, INC. Ernest R. Rahaim Staff Geologist GS/ERR/djb/12-M Manager 'B, ORING NUMBER Date Completed:. SOil DESCRIPTION SILTY GRAVEL W/SOME SAND scattered cobbles, gray, dry SILTY SAND rc/~.~, drv 8.0' SILTY GRAVEL W/SOME SAND gray, dry 11.0' GRAVEL W/SOME SILT AND SAND interbedded with sandy silt gray, dry . 16.0' SANDY SILT W/SOME GRAVEL gray, dry 20.0' T.D. LOCATION SKETCH No Scale HOUSE ] Existing ~35' System NOTE: DISTANCES SHOWN ARE APPROXIMATE AND HAVE NOT BEEN MEASURED BY SURVEYING METHODS. EXPLANATION ORGANIC (~Ss, 72, 5~ I°/o, 85.9 pcf BEDROCK SAMPLER SOil SYMBOLS Lot 7, Block 4, Timberlane Subdivision Anchorage, Alaska GRID. PROJ. NO. 85115 LDwG'NO' n-01 ~ December 27, 1978 Loyd Fladgard c/o Polar Realty Page -3- ELAPSED TIME PERCOLATION TEST Table 1 R&M No. 851159 FEET INCHES DROP IN INCHES 0 0 0 0 1 .3' 3.6 3.6 3 .5' 6 2.4 5 .7' 8°4 2.4 10 1.0' 12 3.6 20 1.5' 18 6 30 1.9' 22.8 4.8 40 2.2' 26.4 3.6 50 2.45' 29.4 3.0 60 2.65' 31.8 2.4 .75 inches 3.3 minutes per inch GRE' TER ANCHORAGE AREA BOROUGH · Depart men[ ;~3~n~ir~er~;ntal quality' Anchorage, Alaska 99503 INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM LOCATION MAILING ADDRESS ~Ol/m/,f"'~ ,/c//]7T.F~, PHONE LEGAL DESCRIPTION ,/~ SEPTIC TANK: DISTANCE r_~ ! FROM WE LL/(~ INSIDE LENGTH NUMBER OF MANUFACTURER ~'~//YO 2~'~L MATERIAL ~-g~/~C/;~ ~ ~'~, COMPARTMENTS ~-~ ~' INSIDE WIDTH ~ LIQUID DEPTH ~--LIQUID CAPACITY/~2~-~.~ GALLONS. SEEPAGE PIT: /~///z~ NUMBER OF PITS __ LINING MATERIAL BUILDING FOUNDATION__ ADDITIONAL ABSORPTION DIAMETER __ OR WIDTH . CRIB SIZE: DIAMETER NEAREST LOT LINE LENGTH DEPTH DEPTH DISTANCE FROM: WELL TOTAL EFFECTIVE ABSORPTION AREA (WALL AREA) .SQ. FT. WELL: TYPE ~/~///~ CONSTRUCTION ~ BUILDING / /~) .~. NEAREST/ z..L NEAREST LOT LINE --~)-- SEWER LINE FOUNDATION OTHER SOURCES . DISAPPROVED CESSPOOL APPROVED DISTANCE FROM: SEPTIC ? SEEPAGE //_..gd2 /7z- TA~NK ./~<:~2 SYSTEM REMARKS DISTANCES: INSTALLED BY: PIPE MATERIAL:/~//~,~.~.-T/~o 4~ LOT SLOPE: Form NO. EQ-031 DIAGRAM OF SYSTEM U'p ' GREATE:R ANCHORAGE: ARE:A BOROUGH DEPARTMENT OF ENVIRONMENTAL QUALITY 3350 "C' STREET ANCHORAGE, ALASKA 99503 TELEPHONE 274-4561 SEWAGE DISPOSAL SYSTEM -- APPLICATION AND PERMIT TO BE INSTALLED BY INSTALLATION OF: SEPTIC TANK , OTHER TYPE AND SIZE OF FACILITY TO BE SERVED FINANCED THROUGH SOIL TEST RESULTS ~//~ COMPLETION DATE ANTICIPATED /~7 ~ SEPTIC TANK SIZE /~)"~"~&~d~j TYPE ~-~/~fl~ ~//J~//~ SEEPAGE AREA SIZE ff/~ TYPE NOTE: THIS t~ERMIT IS NOT VALID WITHOUT SOIL TEST MINIMUM DISTANCES, REQUIREMENTS FOUNDATION TO SEEPAGE PIT DRAIN FIELD SEPTIC TANK TO SEEPAGE PIT WALL /~ ~ TO NEAREST LOT LINE. WELL TO sePtiC TANK ~"~' i~ ~ ~t ~/:J/~ DRAin FIELD ~- ALSO CONSIDER AREA WELLS. WATEr ma[N TO SEPTIC TaNK /~ seePAGE PIT TO RIVER, LAKE, STREAM. CAST IRON INTO AND OUT OF SEPTIC TANK AND INTO CRIB CROSSING GAP OF EXCAVATION 5 FEet INTO UND[STURBED SOIL. /J INCH DIAMETER CAST IRON SIPHON PIPES ON SEPTIC TANK AND SEEPAGE PIT FITTED WITH AIRTight REMOVABLE GAPS. GR{AVEL BACKFILL CONFORM TO BOROUGH REGULATIONS REGARDING INSTALLATION. DIAGRAM OF SYSTEM I CERTIFY THAT [ AM FAMILIAR WITH THE REQUIREMENTS OF GREATER ANCHORAGE AREA BOROUGH ORDINANCE NO. 28-68 AND THAT THE ABOVE DESCRIBED SYSTEM IS IN ACCORDANCE WITH SAID CODE. · _ ~...~ ~ i ~4UNICIPALITY OF ANCHORAGE MUNICIPALITY OF ANCHORAGE DEPT. ©7 H~ALTH & DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECT~)I~/'JRONMEHTAL PF, O; EC¥ION REQUEST FOR APPROVAL OF INDIVIDUAL WATER AND SEWER FA - ' DIRECTIONS: Complete all parts on page 1. Incomplete requests will not be processed. Please allow ten (10) days for processing. 1. PROPERTY OWNER PHONE MAI LING ADDH ESSe ~ PROP ERTY R ESI DEN~( If different from~bove) ¢ 2. BUYER MAI LING ADD~ EgS 3. LENDING INSTITUTION MAILING ADDRESS ~ I PHONE PHONE G~- PHONE 4. REALTOR/AGENT MAILING ADDRESS' PHONE z2 z-/a-'~'/ 5. LEGAL DESCRIPTION STREET LOCATION 6. TYPE OF RESIDENCE NUMBER OF BEDROOMS [] One [~ Four J~ SINGLE FAMILY [] Two [] Five [] MULTIPLE FAMILY [] Three [] Six [] Other 7. WATER SUPPLY ~ INDIVI DUAL* * ATTACH WELL LOG. A well Ic~/,i,~;~uired for all wells drilled [] COMMUNITY since June 19715. For wells~dddlled prior to that date, give well [] PUBLIC UTI LITY depth (attach log if available~) ~ t, ~)~ Ju ~¢..~ ~ 8. SEWAGE DISPOSAL SYSTEM I~ INDIVIDUAL/ON-SITE** [] PUBLIC UTILITY **If individual/on-site, give installation date oO'~- ~-- ~'.~-~. If system is over two (2) years old an adequacy test is required by this Department. NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH REQUEST BEFORE PROCESSING CAN BE INITIATED. 72-010(3/78) : THIS SIDE FOR OFFICIAL USE ONLY INSPECTION APPOINTMENTS TIME TIME TIME DATE DATE DATE INSPECTOR INSPECTOR INSPECTOR DIREC'rlONS: 1. TYPE OF RESIDENCE NUMBER OF BEDROOMS [] SINGLE FAMILY [] ONE [] THREE [] FIVE [] OTHER [] MULTIPLE FAMILY [] TWO I~ FOUR [] SIX PERMIT NUMBER 2. WATER SUPPLY [] INDIVIDUAL DEPTH OF WELL [] COMMUNITY DATE DRILLED [] PUBLIC UTI LITY Connection Verified LOG RECEIVED 3. SEWAGE DISPOSAL SYSTEM PERMIT NUMBER [] INDIVIDUAL/ON -SITE DATE INSTALLED []PUBLIC UTILITY Connection Verified INSTALLER []Septic Tank or []HoJding Tank Size: If Tank is homemade SOILS RATING give dimensions: TYPE OF TANK MANUFACTURER TOTAL ABSORPTION AREA MATERIAL 4. DISTANCES WELL TO: Septic/Holding Tank Absorption Area Sewer Line Nearest Lot Line Absorption Area to nearest Lot Line 5. COMMENTS [~.~ONDITIONAL APPROVAL (letter must accompany certificate)""~ c.~.f¥/,~'~'~ , [] DISAPPROVED 72-010 (Rev, 3/78) December 26, 1978 R&M No. 851605 Polar Realty 101 E. International Airport Road Anchorage, Alaska 99502 Attention: Denny O'Day RE: Adequacy Test on Existing Sanitary, Sewer System; Lot 7, Block 4, Timberlane Subdivision, Anchorage, Alaska Dear Mr. O'Day: Per your request of December 19, 1978, we conducted a test of the sanitary sewer system on the above described property. During the test the liquid level in the seepage pit was monitored as 1000 gallons were removed and 700 gallons were pumped back into the seepage pit to the inlet level. All liquid levels were measured below the top of the standpipe and are shown in the following table: Initial Liquid Second Water Third 24-Hour Total Reading Removed Reading Added Reading Reading Drop (Gallons) (Gallons) 5' 1000 6.7" 700 5.5' 5°6' .1' The average specific capacity is 48.8 gallons per inch based on two sets of readings showing 49.0 and 48.6 gallons per inch. After twenty four hours the liquid level was measured again at 5.6 feet. It had dropped .1 feet or 1.2 inches. This indicates an average effluent acceptance rate of 58.56 gallons per day for the surrounding soils. If the 4 bedroom residence on the property is to house 8 people, the average load on the system can be expected to be 600 gallons per day. We can therefore con- clude that the system is not disposing of effluent at an adequate rate for a 4 bedroom residence. We appreciate this opportunity to be of ~ervice to you° Please contact us if you have any questions regarding this letter or if we can be of additional service to you. Very Truly Yours, R&M CONSULTANTS, INC. E. R. Rahaim Staff Geologist ERR/GAS/mac oc,q� 4c,uz- `� u l5"e,p �tj �J U m ~GREATER Af~CHORAGE AREA BOROUGH Department of Bnvironmenta] Ounlitv 3500 Tudor Road, Anchorage, Alaska q9507 279-8686 Date Received Ttme of Ins.ection ~-----7~ ~7'~ Date of Inspection FOR OF ...z,.L~-:R & WATER , Number of Bedrooms: 6. W~el] Data: A. Tvpe~ C. Construction__~ Sewage Disposal System: A. ~nstalled Depth 8. Installer C. Septic Tank: 1. Size 2. Manufacturer D. Seepage Pit: ].. Size 2. Material Disposal Field: Total Length of Lines 8. Distancee: A. Well To: Septic Tank · Absorption Area . Sewer Lines · Nearest Lot Line · Other Contamination B. Foundation to Seotic Tank Absorption Area Co Absorption Area to Nearest Lot Line Request for Approval of ~vidusl Sawar& Water Faczlzt~a~ x. Pag'~ ~T~vo ~'9. Comments: Ap,~rova_~ Valid for One Year. Approved S~oned Greater Anchorage Area .,orouoh Dar~rtment of Environmental Quality I certify that the information contained in this request for approval to be a true and accurate represent~t~an of the suo]~ct se~er an~ water fac~li,les located at: April 30, 1974 Ha.yden Stm?ard Box 10}87 Klatt ~ '- .... · :. ): [;ell approw~l on Lot 7, P, lock 4 'Fiuherl~me Park Subdivision The subject .,~ell was upqraded frrm) a pit using a pitles~ adapter, This type of cons'~-rqction )~;eets our approval for hmalti) stanc)ardA and loan approval s. lr You have any questions, ,)1 .a,e 'Feel free to contact F:)e at 274--4561 extension 137, Sinc~rely~ Control Officer L~/ko July 10, 1972 Firs. Hayden Stewart Lot 7, ~lock 4, TiJ~berlane Park Subdivision llox 10187 Klatt Station, Anchorar!e, Alaska gg5gl !'~ear ?;rs. Ste,//art: Our inspection of your well revealed the following: - ag=. ~Stel~ for FIiA approval upgraded so that the well and the pit is filled i~ with The well is in a pit and ~ust be casing is 1~'~ above ground level in, pervious soil. The sewaoe systet~ must have a 1,25F~ gallon se~tic tank, (four hedroox~ capacity) placed iF; between house and seepage pit. A oer~it and the specifications are available at this department. If you have any questions, please let us know. Sincerely yours, Les Buchholz Enviornmental Control Officer CC: Hr. ~Ieflin 737 Barrow Anchorage~ Alaska 99501