HomeMy WebLinkAboutROSEBUD HILLS BLK 1 LT 4Rosebud Hills Block I Lo1- 4 #017-381-37 Municipality of Anchorage On-Site Water and Wastewater Program • (907) 343-7904 Page 1 of 3 ON-SITE WASTEWATER INSPECTION REPORT Permit Number: OSP151154 PID Number: 017-381-37 Dwelling: 0 Single Family (SF) ❑ Duplex(D) [' Multiple (SF and/or D) Project: El New ❑ Upgrade Name: Eric Trevithick ABSORPTION FIELD Address 3121 Latouche Street Anchorage AK 99508 ❑ Deep Trench ❑■ Shallow Trench ❑ Bed ❑ Mound [' Other Phone Number of Bedrooms Soil Rating Total depth from original grade 301-5359 4 1.2 GPD/SF 5.4 Ft. LEGAL DESCRIPTION Depth to pipe invert from original grade Gravel depth beneath pipe Subdivision Block Lot 1.2 Ft.4.2 Ft. Rosebud Hills 1 4 Fill added above original grade Gravel length Township Range Section 4,2 Ft. 54 Ft. Gravel width Beds:Number of Lines Distance between lines SEPARATION DISTANCES 5 Ft. Ft. To' Septic Absorption Lift Station Holding Sewer Total absorption area Number of trenches Dist.between trenches From Tank Field Tank Line 540 Ft2 1 Ft. Well >100' >100' N/A N/A >25' TANK ❑r• Septic ❑S.T.E.P. ❑Holding ❑Other Manufacturer Capacity Surface Water >100' >WU i N/A N/A i Anchorage Tank 1250 Gal. Material Number of compartments Lot Line >5' 10' N/A N/A Steel 2 NA Foundation >5' >10' N/A N/A LIFT STATION Manufacturer Capacity Curtain Drain None i Noted Gal. Remarks Pump on level at Pump off level at High water alarm at in. in. in. Pump make and model Electrical Inspections performed by PIPE MATERIAL House to tankD3034 Tank to Installer drainfield D3034 Alaska General __ Drainfield D3034 CO/MT D3034 Inspector Mike Anderson BENCH MARK (Assumed elevation) 100 ft Inspection dates: •' 7/01/1 5 20d Location and description 3rd 45 Garage Slab COMMUNITY DEVELOPMENT DEPARTMENT APPROVALIllibEVIrlaq� , Conditional Approval: Date :-'• :r r 41.• A a- ..v ist . i 4r . �':.� i* f ra:-7-3 ''........ -. V ;ern , r in 1 Walk: iM . my I ` .� o I Approv d ( t t"A.C;fleA4 Date) 1a) 17 eve i4PnlAi1pF > v4 Inspection Report_9-1-12.doc On-Site Water & Wastewater System Permit  MUNICIPALITY OF ANCHORAGE Development Services Department On-Site Water & Wastewater Program 4700 Elmore Road, PO Box 196650 Anchorage, AK 99519-6650 Telephone: (907) 343-7904 Permit Number: OSP151154 Tax Code Number: 01738137000 Work Type: WellSeptic Initial Permit Effective Dates: June 16, 2015 to June 15, 2016 Design Engineer: ANDERSON ENGINEERING Subdivision: ROSEBUD HILLS Site LegalAddress: ROSEBUD HILLS BLK 1 LT 4 G:2837 Owner/Address: JOY AUSTIN J & REGENA S PO BOX 111073 ANCHORAGE AK 995111073 Site Mailing Address: 5531 RIDGEVIEW DR, Anchorage Lot Size in Sq Ft: 52220 Total Bedrooms: 4 ~enr This permit is for the construction of: Y Disposal Field Y SepticTank N Holding Tank N Privy Y Private Well N Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80). 3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either: A. Open and Close on the same day. B. Covered, sealed, and heated to prevent freezing. Received By: MUNICIPALITY OF ANCHORAGE Community Development Department ~ Phone: 907-34~ Development Services Division ~ Fax: On-Site Water& Westewater Program ON-SITE SEWER~ELL PERMIT APPLICATION (~-~ JUNO 1 Z015 Parcel I,D. 017-381-37 ~ k~ Properly owner(s) Austin & Regena Joy ~ Day phone 250-1~~~ Mailing address P.O. Box 111073 Anchorage, AK 99511 Site address NHN Ridgeview Drive Anchorage, AK 99516 Legal description (Sub'd, Block & Lot) Rosebud Hills, Block 1, Lot 4 Legal description (Township, Range & Section) Lot Size 52,220 .Sq. Ft. Number of Bedrooms Four APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: ([~ all that apply) Absorption Field [] Initial [] Single Family (SF) [] (w/wo ADU) Septic Tank [] Upgrade [] Duplex (D) [] Holding Tank [] Renewal [] Multiple Dwellings [] Pdvy [] (SF and/or D) Private Well [] Water Storage [] THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes, (Signature of property owner or authorized agent) Permit/Rush Fees: Date of Payment: Receipt Number: Permit No. O~1¢1~ Waiver Fees: Date of Payment: Receipt Number: Waiver No. Permit App_9-1-12.doc ANDERSON ENGINEERING P'O, BOX 240773 ANCHORAGE, AK 99524 522-7773 677-7766 (FAX) June 1, 2015 Municipality of Anchorage Development Services Department On-Site Water and Wastewater Program 4700 South Bragaw Street Anchorage, AK 99519-6650 Subject: Lot 4, Block 1, Cross View Estates Subdivision Septic System Design and Permit Application Impacts to Adjacent Properties Dear Onsite Services Engineer: The owner of Lot 4, Block 1, Rosebud Hills Subdivision intends to construct a new four- bedroom home on the lot. We are therefore requesting a permit be issued for the construction of a new well and septic system to accommodate the home. The attached Site Plan and backup documentation identify the location and configuration of the proposed well and septic system along with the alternate site. Also identified on the plans are the existing wells and septic systems on surrounding lots. No conflicts exist between the proposed septic system and well or septic systems and wells on adjacent lots. Drainage arrows and ground surface contours are shown on the site plan showing the grade and direction of flow on the lot. The drainage pattern will not be changed as a result of this project. Two test holes were placed on the lot in the area of the absorption trench and alternate site. The logs indicate silty sand (SM) in the zone specified for the absorption trench. The percolation rate of the soil was determined to be 1-5 minutes per inch. No groundwater was found during the placement of the test holes and none was noted during the monitoring period. An application rate of 1.2 gallons per day per square foot was used in the design of the absorption system. We are proposing to place a new 1,250-gallon septic tank and a 50' long by 5' wide by 4' effective depth absorption trench to treat and dispose of the effluent generated in the house. The elevation of the distribution line in the absorption trench will be 2' below the surface and the total depth will be 6'. A minimum of 3' of fill or 2" of insulation and 2' of fill will be placed over the absorption trench and 4' over the septic tank. The ground surface on the lot in the area of the septic system slopes to the southwest. The new trench will be constructed parallel with the contours of the slope as much as Lot 4, Block 1, Rosebud Hills Subdivision June 1, 2015 Page Two possible in conformance with Municipal requirements. The new septic system will be constructed a minimum of 100' from all wells and any surface water and 10' the proposed and existing water services in the area. If the system is constructed in accordance with our design the following statements apply: The system, if constructed as designed, will have no adverse impact on the wells in the area or those to be constructed in the future. The system, if constructed as designed, will have no adverse impact on existing septic systems in the area or those to be constructed in the future. The system, if constructed as designed, will have no adverse impact on reserve space, either surface or subsurface, on any lots located in the area. The system, if constructed as designed, will have no adverse impact on drainage patterns in the area. The current drainage pattern will be maintained. Sincerely, Michael E. Anderson, P.E. Attachments ROSEBUD HILLS SUeDIVISION LOT47,2994, BLOCKs. F. LOT ~ Existing (~) Well LOT 3 N89'41'17"F~ 158..~6~" 10' U__t~ Easement ROSEBUD PJJLLS SUBDIVISION L/CrT 4, BLOCK 1 / 47,299 S.F. / Four Bedroom Home ~ ~ ~ 50 Long x 5~Wir~e \ Y LOT 4 ~ BLOCK 1 Proposed 12' Drive ~Proposed i~/ell / / / / / 158.26' S89'59'43"W SITE PLAN SCALE l' = 40' RIDGEVIEW DRIVE MT%- Monitor Tube FCO' %. Foundation Clean Out TH -Test Hole CO - Cle~ O~t 2C0 -- Bauble Ole~cLOut FSV - Flow Splitter Vol~- -- NOTE: No Areas of Excesslve Slope or Sudace Water are Within 100' of Any Par[ of the New Septic System, ~. 7~ ~ MICHAEL E. ANDERSON ,'.~ LOT 4, BLOCK 1, ROSEBUD HILLS SUBDIVISION DESIGN FACTORS: SYSTEM REQUIREMENTS: Four Bedroom Home 5' Wide Trench System Perc. Rate: 1-5 Min./Inch 1,250 Gallon Septic Tank Application Rate: 1.2 GPD/SF 4' Drainfield Rock 4 Bedrooms * 160 GPD/Bedroom = 600 SF Absorption Area 600 SF/1.2 GPD/SF/5 SF (Width) *.5 (Red. Factor)= 50 LF Trench Length THEREFORE: Construct a 50' Long x 5' Wide x 4' Effective Depth Absorption Trench. Flow Line Elevation in Trench to be 2' Below Original Ground Surface. Total Depth to be 6' Below Existing Ground. Provide 3' Cover Over Absorption Trench and 4' Cover Over Septic Tank. Maintain 100' Separation From All Wells and Surface Water in the Area. ..........~eotextile Fabric 4" Perforated PVC (Holes Down) Drainfield Rock 59 TYPICAL 5' WIDE TRENCH SECTION -- -- -- ~CALE--'ET~ ~**.~%..~. ...... · . ...... NOTE Grade Area Over Trench to Dra~n Away ~ ~ '~' Minimum 6' Separation From Bedrock. ~.....~.~..~.~.......~.....,~..~ Minimum 4' Separation From Groundwater. ~~ Minimum 100' Separation From Private Wells in the Area ~ ~,~A~ Minimum 100' Separation From Su~ace Water or Stream~: ~ MUNICIPALITY OF ANCHORAGE DEVELOPMENT SERVICES DEPARTMENT BRAGAW STREET ANCHORAGE, AK 99519-6650 t, 700 [ SOILS LOG - PERCOLATION TEST LEGAL DESCRIPTION: LOT ~, BLOCK I, ROSEBUD HILLS PERFORMED FOR: ,JAY JOy DATE: 5/Ig/15 PARCEL ID#: PROJECT No.: TECHNICIAN: W. ROBERTS DEPTH ] TEST HOLE 1 [ (feet) OB/OG SLOPE 1 2 3 4 5 ~ 6 7 8 S~LTY GRAVEL GM/ML 9-- sM WAS GROUND WATER ENCOUNTERED? NO 11 20 SITE PLAN SEE SITE P[ AN 5% ~ B0H @ 15' DEPTH TO DATE READING GROSS TIME NET TIME WATER NET DROF (MINUTES) (MINUTES) (INCHES) (INCHES) TEST HOLE PRESOAKED PRIOR TO TESTING: 5/12 1 11:02 0.75" 2 11:32 30 9.13" 8.38" 3 11:33 1.00" 4 12:03 30 9.50" 8.50" 5 12:04 1.00" 6 12:34 30 9.50" 8.50" PERCOLATIONRATE:3.50(MIN/INCH) PERC. HOLE DIA. 6" (INCHES) TESTRUN BETWEEN: 4.0 FT. and 5.0 FT. COMMENTS: TEST HOLE PRE SOAKED PRIOR TO TEST. TEST PERFORMED BY ANDERSON ENGINEERING. l, MICHAEL E. ANDERSON CERTIFY THAT THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPLE GUIDELINES 1N EFFECT ON THIS DATE:, 6/I/15 &700 [ MUNICIPALITY Of ANCHORAGE DEVELOPMENT SERVICES DEPARTMENT BRA(SAW STREET ANCHORA(SE, AK 995~9-6650 LEGAL DESCRIPTION: PERFORMED FOR: DATE: 5/12/15 PARCEL ID#: DEPTH (feet) OB/OG 2 3 4 5 6 8 SILTY GRAVEL GH/ML 9 sm 11 B0H @ 12' 20 SOILS LOG - PERCOLATION TEST LOT Z+, BLOCK I, ROSEBUD HILLS JAY JOY PROJECT No.: TECHNICIAN: W. ROBERTS SLOPE NO WAS GROUND WATER ENCOUNTERED? 1F YES @ WHAT DEPTH?.__ DEPTtt OF WATER AFTER MONITORING: NONE DATE OF MONITORING:. 5/20/15 SITE PLAN DEPTH TO DATE READING GROSS TIMEINET TIME WATER NET DROF (MINUTES) (MINUTES) (INCHES) (INCHES) TEST HOLE PRESOAKED PRIOR TO TESTING: 5/12 1 1:15 2.25" 2 1:45 30 10.25" 8.00" 3 1:46 2.38" 4 2:16 30 10.38" 8.00" 5 2:17 2.00" 6 2:47 30 10.00!' 8.00" PERCOLATION RATE:3.75(MIN/INCH) PERC. HOLE DIA. 6" (INCHES) TESTRUN BETWEEN: 4.0 FT. and 5.0 FT. COMMENTS: TEST HOLE PRE SOAKED PRIOR TO TEST. TEST PERFORMED BY ANDERSON ENGINEERING. I, MICHAEL E. ANDERSON CERTIFY THAT THIS WAS PERFORMED 1N ACCORDANCE WITH ALL STATE AND MUNICIPLE GUIDELINES IN EFFECT ON THIS DATE 6/I/15 Municipality of Anchorage On-Site Water and Wastewater Program • (907) 343-7904 Page 1 of 3 ON-SITE WASTEWATER INSPECTION REPORT Permit Number: OSP151154 PID Number: 017-381-37 Dwelling: 0 Single Family (SF) ❑ Duplex(D) [' Multiple (SF and/or D) Project: El New ❑ Upgrade Name: Eric Trevithick ABSORPTION FIELD Address 3121 Latouche Street Anchorage AK 99508 ❑ Deep Trench ❑■ Shallow Trench ❑ Bed ❑ Mound [' Other Phone Number of Bedrooms Soil Rating Total depth from original grade 301-5359 4 1.2 GPD/SF 5.4 Ft. LEGAL DESCRIPTION Depth to pipe invert from original grade Gravel depth beneath pipe Subdivision Block Lot 1.2 Ft.4.2 Ft. Rosebud Hills 1 4 Fill added above original grade Gravel length Township Range Section 4,2 Ft. 54 Ft. Gravel width Beds:Number of Lines Distance between lines SEPARATION DISTANCES 5 Ft. Ft. To' Septic Absorption Lift Station Holding Sewer Total absorption area Number of trenches Dist.between trenches From Tank Field Tank Line 540 Ft2 1 Ft. Well >100' >100' N/A N/A >25' TANK ❑r• Septic ❑S.T.E.P. ❑Holding ❑Other Manufacturer Capacity Surface Water >100' >WU i N/A N/A i Anchorage Tank 1250 Gal. Material Number of compartments Lot Line >5' 10' N/A N/A Steel 2 NA Foundation >5' >10' N/A N/A LIFT STATION Manufacturer Capacity Curtain Drain None i Noted Gal. Remarks Pump on level at Pump off level at High water alarm at in. in. in. Pump make and model Electrical Inspections performed by PIPE MATERIAL House to tankD3034 Tank to Installer drainfield D3034 Alaska General __ Drainfield D3034 CO/MT D3034 Inspector Mike Anderson BENCH MARK (Assumed elevation) 100 ft Inspection dates: •' 7/01/1 5 20d Location and description 3rd 45 Garage Slab COMMUNITY DEVELOPMENT DEPARTMENT APPROVALIllibEVIrlaq� , Conditional Approval: Date :-'• :r r 41.• A a- ..v ist . i 4r . �':.� i* f ra:-7-3 ''........ -. V ;ern , r in 1 Walk: iM . my I ` .� o I Approv d ( t t"A.C;fleA4 Date) 1a) 17 eve i4PnlAi1pF > v4 Inspection Report_9-1-12.doc ROSEBUD HILLS SUB, BLOCK 1 LOT 4 PERMIT # OSP151154 PID # 017-381-37 MUNICIPALITY OF ANCHORAGE DEVELOPMENT SERVICES DEPARTMENT: 343-7904 4700 ELMORE RD, ANCHORAGE, AK 99519-6655 WASTEWATER DISPOSAL SYSTEM OR WELL INSPECTION REPORT O CV 0 o > > 0 LL U) U) cV - - /_96.2 - - - INSULATION 93.2 93.0 J 92.7 I 1250 GAL 92.6k 92.5 SEPTIC TANK J ! 88.21 97.7 FINISH GRADE O7/-93.5 ORIGINAL GRADE U 92.3��_----`= . ; -,. ,PAIMDRAINFIELDROCK - „ _.. �. --- .., 92.3 88 1 54' 81.5 (V = NO GROUNDWATER 5/20/15 I— Pte••• i ." ,-•:Fy+0, ;"*I49 TM )• .* �/ PROFILE AS-BUILT j • Ben in Schiller PFp•. CE 12592 .•ate �`` df•.• Nw 13.2017 . r (NO SCALE) 11�;F�pROfE5S10NA��� ROSEBUD HILLS SUB, BLOCK 1 LOT 4 PERMIT # OSP151154 PID # 017-381-37 CONTOUR ACRES I LOT 3 17 LMdiry Easement LOT 4 WELL —\31 O 4-BDRM HOME FCO 1250-GAL SEPTIC TANK . QQ LOT CO1 • • SV S� 2C0 DTH 1 •MT1 • LOT 3 ABSORPTION TRENCH 54'x 5'x 4'EFFECTIVE s • -. ALTERNATE SITE — • ‘•.TH 2 •Oa' t) A B C FCO - 7.0 20.0_ $ ' CO1 58.3 28.1 SV1 58.4 30.8 PROPOSED ERNE SV2 56.4 35.0 - 2C0 55.2 38.5 - 0O2 54.6 43.1 - MT1 56.8 46.7 CO3 76.4 91.3 i RIDGEVIEW DRIVE 4 \‘kio - j*: M * 6 LEGEND ... MT-MONITORING TUBE / Benj in Schiller ' FCO-FOUNDATION CLEANOUT 9ec • + •. A L 12592 � � TH-TEST HOLE TiNor`1FRf �pNOF5.2017NA`•+•� 0 50 100 SV-SEPTIC VENT \\\ � FEET CO-CLEANOUT 1"=50' Development Services Department Building Safety division On-Site Water & Wastewater Program 4700 Elmore Road r. _ P.D. Box 196650 .17 1 Mark Begich Anchorage, AK 99507 s ' ' ` Mayor www.muni.or /orsitz (907)343-7944 Pump Installation Log Well Drilling Permit Number: 0 sp J 5 J 1 S-1 Date of Issue: i lilt t 1 fl 2016- Parcel 01SParcel Identification Number: �- Legal Description Property Owner Name& Address: Rost bat 14 U') bitd LOA' q 'Tee v; gt.,i 1deYS G; A37 e oa, x..3053`( Pen vtin. 9 )3 ~Pump Installation Date: b— 42,-17 Pump Intake Depth Below Top of Well Casing: 330 feet Pump Manufacturer's Name: Lk kr* l Pump Model: 5 51)", Pump Size ) hp, • i Pitless Adapter Burial Depth: /L0 feet r Pitless Adapter Manufacturer's Name: C G *it "! 0 Pitless Adapter Installer: VA. Well Disinfected Upon Completion? Yes 1— No Method of Disinfection: cAt Comments: Pump Installer Name: ...),Lt-47 • Attention: The pump installer shall provide a pump installation log to the DSD within 30 days of pump installation. development Services Department Building Safety Division �''-. On-Site Water & Wastewater Program - 4700 Elmore Road = P.O. Box 196650 Anchorage, AK 99507 : - r Mark Begioh www Muni arg!nrsste x Mayor ,, Y_ Well Log Permit Number:O5P151154 Date of Issue:June 16, 2015 Date Started:06-24-15 Date Completed:07-01-15 Is well located at approved permit location?U Yes L No Legal Description: Rosebud Hills blockl lot4 G:2837 Property Owner Name&Address: Joy Austin J & Regena S P.O. Box 111073 Anchorage,AK 99511 Borehole Data: Depth (ft) Method of Drilling Di]air rotary L cable tool Soil Type,Thickness& Water Strata From To . T _ _ Casing type:steel stickup 0 2 Wall Thickness:,250 inches silt w/rock 2 18 Diameter: 6 -inches Depth: .138_feet —_ __.--_..-__--- Liner Type: silt&gravel 18 80 Diameter: inches Depth: _ __ feet silt 80 95 Casing stickup above ground: 2 feet moist silt w/gravel 95 120 Static water level(from ground level): __120 feet wet gravel 120 126 Pumping level: feet after dry silt & gravel 126 138 hours pumping gpm -- — Recovery Rate: 1 gpm - bedrock • 138 345 Method of Testing: airlift Well Intake Opening Type: 7 Open End n Open Hole ❑ Screened Start feet Stopped feet El Perforations Start feet Stopped_ _ __feet - - — Grout Type: Bentonite Volume:granules Depth: 20' Start 0 feet Stopped 20 feet • Vi t-ii QUALITY TESTING Pump: Intake Depth feet C_'-u;i1Orrn Col/QQ Pump size hp Brand Name LY Well Disinfected Upon Completion? n Yes n No 1 r-;"rti ----___D__ -/AA_ ' . Method of Disinfection:chlorine tablets -.-.__ _ Comments: --- _ Well Driller: Hefty Drilling, Inc. --______-- 3540 Akula Dr. Water Sample Results: -__._._._._ ___ ___ __ _.._. Anchorage,AK 99516 Arsenic: ugIL Nitrates: _mg/L Total Coliform Bacteria: ____colonies/100mL Other Bacteria: coil100mL Attention: The well driller shall provide a well log to DSD within 30 days of completion. •, � Municipality of Anchorage ''' �� u° .j: On-Site Water and Wastewater Prograrrwu,� t; Z017 ` (907) 343-7904 SAF F,. Certificate of On-Site Systems A { r !d�ijyyd g Parcel I.D. 017-381 -37 Expiration Date: 2."2 r( 1. GENERAL INFORMATION Complete legal description Rosebud Hills, Block 1 Lot 4 Location (site address) 5531 Ridgeview Drive Current Property owner(s) Eric Trevithick Day phone 301 -5359 Mailing address 3121 Latouche St, Anchorage, AK 99508 Real Estate Agent Day phone 2. TYPE OF DWELLING: O Single Family (w/wo ADU) ❑ Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) 3. NUMBER OF BEDROOMS: 4 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well Individual Individual Water Storage ❑ Holding Tank ❑ Community Class Well ❑ Community ❑ Public Water System ❑ Public Sewer ❑ WaiverNariance request for: Distance: Received by: „` ,; ' ) Date: COSA to be released to the engineer,unless otherwise requested by the engineer. COSA Fee $ �vl gr "I " l�� 1 II, bh Waiver Fee $ Date of Payment //' 7-1-17 Date of Payment Receipt Number an 12-D Receipt Number COSA# CI6C-11151 Waiver# 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm Forge Engineering Phone 522-7773 Address PO Box 240773, Anchorage, AK 99524 Engineer's Printed Name Benjamin Schiller, PE Date 11/15/17 1:19. ...* °° 49TH }•4� ° 6. DSD SIGNATURE . 'f.• •• System#1 Approved for bedrooms • r. �ll`•'��0 B System#2 Approved for bedrooms 40¢t°°. �C • oo°11d �,. 111 l 6•,".G° A. Disapproved �9 *'�i''i N..• ‘� Conditional approval for bedrooms, with the following stipulations:- _ ON-SITE 1)1'.,,,, = WATER AND c1 WASTEWATER o o PROGRAM O 2r"IT SER\AC'��, . .� Original Certificate Date: 1 (" 2I —! 7 The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On-Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. .- • 7. ATTACHMENTS: - - COSA Checklist X Nitrate Advisory. Septic System Advisory Arsenio Advisory - - Well Flow Advisory Other . . COSA blue sheet_c '- 0 If more than 1 septic system is on the lot: COSA Checklist# of Structure served by this system Certificate of On-Site Systems Approval Checklist Legal Description: Rosebud Hills, Block 1 Lot 4 Parcel ID: 017-381 -37 A. WELL DATA Well type Private If A, B, or C provide PWSID # Well Log (YIN) Y Date completed 7/01/15 Sanitary seal (Y/N) Y Wires properly protected (YIN) Y Total depth 345 ft. Cased to 138 ft. Casing height(above ground) >24 in. FROM WELL LOG AT INSPECTION Date of test 7/01/15 New Static water level 120 ft. ft. Well production 1 g.p.m. g.p m WATER SAMPLE RESULTS: Coliform ND colonies/100 mL Nitrate 1 .77 mg/L Arsenic ND D ug/L Date of sample: 9/7/2017* Collected by. Forge Eng *Second sample collected 9/18/17 for choliform after disinfecting well B. SEPTIC/HOLDING TANK DATA Tank Type/Material Septic / Steel Date installed 7/01/15 Tank size 1250 gal. Number of Compartments 2 Cleanouts (YIN) Y Foundation cleanout (Y/N) Y Depression over tank (Y/N) N High water alarm (Y/N) N Date of pumping Pumper New Construction C. ABSORPTION FIELD DATA Date installed 7/01/15 Soil rating (g.p d./ft2 or ft2/bdrm) 1 .2 System type 5-Wide Length 54.0 ftWidth 5.0 ft. Gravel below pipe 4.2 ft. Total depth 9.6 ft. Eff. absorption area 540 ft2 Monitoring tube Y Depression over field N Date of adequacy test New Results (Pass/Fail) For bedrooms Fluid depth in absorption field before test in. Water added gal. New depth in. Elapsed Time: 'min. Final fluid depth in. Absorption rate >= g.p.d. Any rejuvenation treatment(past 12 mo.) (Y/N &type) If yes, give date D. LIFT STATION Date installed Size in gallons Manhole/Access (Y/N) "Pump on" level at in. "Pump off' level at in. High water alarm level at in. Datum Cycles tested Meets alarm&circuit requirements? E. SEPARATION DISTANCES WELL ON LOT TO: Septic tank/lift station on lot >100' On adjacent lots >100' Absorption field on lot >100'100' On adjacent lots >100' Public sewer main >75' Public sewer manhole/cleanout >100' Sewer/septic service line >25' Holding tank >75' Animal containment areas >50' Manure/animal excrete storage areas >100' SEPTIC/HOLDING TANK ON LOT TO: >5' >5' >5' Building foundation Property line Absorption field Water main >10'10' Water service line >10'10' Surface water >100' Wells on adjacent lots >100' ABSORPTION FIELD ON LOT TO: Property line >10Building foundation >10 Water main >10 Water Service line >10Surface water >100 Driveway, parking/vehicle storage >10' Curtain drain None Noted Wells on adjacent lots >100' F. COMMENTS G. ENGINEER'S CERTIFICATION jAbit.,Or df,4,4 to or I certify that I have determined through field inspections and III III. •• - -' ;,,r '•;¢•rt review of Municipal records that the above systems are in i LOT 3 if-Found existing 5/8" Rebar (Typ.) N89'41'17"E _ ..._ g j 158.26' 10' Utility Easement i� 0 0 Well —27.8' . 19.3q.! 12.3 Bay Window cv,E 'a o. 7.1' 3. 0 ' �i _ • In24.7 co 2.82.8, ; I .re) j �, &.I X27.8'— 510.5' , Wood Pad 11-f: o,r;; 14.3' _I r.K N 6. Covered,!i 23.0' ;IWood Deck;: 6.0' 0 r 15.8 - 3.3' 9.2 3.3' N6.0'. w 1 Window 52.3' ol±—4 Case __- - . ,. r__ . . Concrete/ Walk Asphalt ri, Pad z -_-. w -in \ -0, n M LOT 3 0 ! In N Riser Pipe LOT 5 0 (Typ.) 0 • 0 0 z Recycled Drive LOT 4 BLOCK 1 j . N Dirt 9 a 0 SCALE : 1 " = 30' 2: plIIMIII co 0' 15' 30' 60' 158.26' S89'59'43"W • o b • ro "D _ RIDGEVIEW DRIVE _ _ _ NOTE: PREPARED FOR: Dimensions are measured to the wood trim. ERIC TREVITHICK I hereby certify that an accurate survey of the following described property: AS - 3UILT , c. ........A( *t ROSEBUD HILLS SUBDIVISION (74-187 / SifP B ' •• ��•.P,F LOT 4,BLOCK 1 : ***:57-4 was made on October, 11, 2017 and that the improvements OWN. DATE GRID *F49TH „" �0 situated thereon are within the property lines and do not overlap or JSP 10/21/2017 SW 2837 x Ma encroach on the property lying adjacent thereto, that no to AV. Lee'Knrnbelnikof. improvements on the property lying adjacent thereto encroach on FILE NO. F.B. JOB NO. 0, ;A,if the premises in question and that there are no roadways, 1716 2016/2017 1731 • No, 3143-S••= .. transmission lines or other visible easements on said property except PG. 32 iv t1 ••'••.......••''l9 �w as indicated hereon. Easements other than those shown on the I� p /� • N Mkt ...."S13414-ik �s'� record plat may not appear on this drawing. I"\ ARADELI V I KOFF /AAi/31017 Anchorage Alaska. this 21th day of October 2017. SURVEYING (907) 337-3434 V)