Loading...
HomeMy WebLinkAboutALTA'S VIEW LT 2Alta"s View #051-312-47 _a_ ' Municipality Anchorage 6 of _t , Development Services Department 0 Building Safety Division On -Site Water and Wastewater Program, 4700 Elmore St. P.O. Box 196650 Anchorage, AK 99519-6650 Page 1 www.ci.anchorage.ak.us (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT Permit Number: SW090134 PID Number: tO i (.-. —312-30 of 3 Name: Rich Moon Wastewater System: New 5 Upgrade Address: 17833 James Way ABSORPTION FIELD Phone: Number of Bedrooms: 223 2449 5 or Deep Trench 0 Shallow Trench 0 Bed 0 Mound 0 Other: LEGAL DESCRIPTION sail Rating: 1 GPWFI° Total Depth from original grade: 9 Ft. Block: Lot: Subdivision: Depth to pipe bottom from original grade: 6 Ft. Gravel depth beneath pipe: 3 Ft. te.-1145 Township: T 15 NtanR 2 W SEC La! liorL. 1 14 5 Fill added above original grade: 0.5+ Ft. Gravel Length: 91 Ft. Well: Existinrfl New ❑ Upgrade Gravel width: 6 Ft. Number of lines: 1 _ Distance between lines: — Ft. Classification (Private, A, B. C): Total Depth: Ft. Cased to: Ft. Total absorption area: 784 Fe Pipe Material: PVC 3034 Driller. Date Drilled: Static Water Level: Ft. Installer: flwnpr Date Installed: 9/11/09 Yield: GPM Pump Set at: Ft. Casing Height Above Ground: Ft. TANK SEPARATION DISTANCES in Septic ■ Holding ■ S.T.E.P. • Other: To From Septic Tank Absorption Field Lift Station Holding Tank 'ohne/Private Sewer Line Manufacturer:Capacity: Anchorage Tank 1500 Gal. Well 1001+ 100'— NA NA 25'+ Material: Steel Numr of Compartments: Surface Water 100'+ 100'— NA NA LIFT STATION Lot Line 10'+ 10'+ NA NA Size: Gal. Manufacturer. Ilr- Foundation 101+ 10'+ NA NA 'Pump on' level at: In. 'level aC igh water alarm at: in. in. Curtain Drain NA NA NA NA Pump Make & Model cal Inspections performed . Remarks: ❑WI'1C1" Construction BENCH MARK Location and Description: Sidewalk Slab @Mother In—LttWed Elevation: 100 Ft. NorthRim Engineering Inspections performed by: Dates: 1st 8/27/0`- Engineer's Stamp _,c,47,-.44,04.‘‘3/4110. rid 9/11/U9 2 +rrr O$'Atte> ...,....e• FP" y64; B A Development Services Department Approval Conditional Approval Date: ti.. �' Lal ,:• 0 J ' f �� ) �a 10 et/^�••='�•��•=,' Reviewed and approved by: ty/� ' / ate: ti -234 � tot %,,,_.„ ; Steven W. Eng y � • - r17.01 t k k,r. RECORD DWG MEASUREMENTS A B ST CO1 51 82 STCO2 54 78 DCO 57 77 CO 2 124 101 MT 60 79 Decommissioned Septic Tank Old Trench L_ BLM 50' Easements James Way NORTHR/M ENGINEERING PO Box 770724 Eagle River. Alaska 99577 907.694. 7028 Powerline Corridor New 1500 Gallon Septic Tank \ 5 % slope MT ouble C.O.'s T15N R2W Section 25 BLM LOT 145 NEW TRENCH/TANK SEPTIC SYSTEM 1' = 50' RECORD DRAWING oma.: 9/30/09 2of 3 ❑NIMdeJQ Q?J033e1 GN3 HCN❑SII 1/40 w 0 0 G ul 1 0 n 3 (n Mad NSIl 0 n O Ul ro A h 0 w 'O G) viZ ri ri El ICA o D Z Ll 7C D r r 0 z 6 = uoi}onai upua.il MSN do }uiod-pm o f Opposing Cleanouts Between Septic Tank & Bed }nouoap uoitopunod 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 r\1aRTHrIM ENGINEERING S❑ILS LOG - PERC❑LATI❑N TEST Performed For: Rich Moon Date Performed: 8/27/09 Legal Description: BLM Lot 145 DEPTH (FEET) Organic SM Silty Sand w/ Gravel Denser @ Depth T.H. Location: See Attached Design Flat Terrain Groundwater? No Depth Water Depth After Monitoring. None Date: 9/5 # Date Gross Tirne Net Tine Depth Net Drop 1 8/27 0 -- 5" -- 2 8/27 10 10 rnir. 7" 2" 3 8/27 12 -- 5" -- 4 8/27 22 10 Hr. 7" 2' 5 8/27 25 -- 5" -- 6 8/27 35 10 nir, 7" 2" 7 8/27 37 -- 5" -- 8 8/27 47 10 nir, 7" 2" 9 8/27 50 -- 5" -- 10 8/27 60 10 nir, 7" 2" Percolation Rate 5 min,/inch Perc Hole Diameter 6' Test Run Between 4' and 5' Comments. Presoaked Performed By NrrthRim Fng I CERTIFY THAT THIS TEST WAS Performed in Accordance with All State/Municipal Guidelines in Effect ON THIS DATE. DATE' 8/27/09 NORTHF?IM ENGINEERING PO Box 770724 Eagle Rher, Alaska 99377 907.694.7028 714 �°. � �: * 9m- e T. H. 2 TESTHILE LIG BLM LIT 145 ` slim W '� •., a Vill GEITECHNICAL Date: 8/27/09 2rof 2 MUNICIPALITY OF ANCHORAGE Development Services Department On -Site Water & Wastewater Program 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT Upgrade Permit Number: SW090134 Legal Description: T15N R2W SEC 25 LT 145 Design Engineer: 0838 NORTH RIM ENGINEERING Owner Name: RICHARD MOON Owner Address: 17833 JAMES WAY EAGLE RIVER , AK 99577-9254 Date Issued: Aug 04, 2009 Expiration Date: Aug 04, 2010 Parcel ID: 051-312-30 Site Address: 017833 JAMES WAY Lot Size: 100000 SQ. FT. Total Bedrooms: 0 Permit Bedrooms: 5 This permit is for the construction of: ❑✓ Disposal Field ❑✓ Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ). 3. The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. 5. The following special provisions. A. THE ENTIRE SUBSURFACE DISPOSAL FIELD IS NOT WITHIN 30 FEET OF A PERCOLATION TEST. THE ENGINEER NEEDS TO DO AN ADDITIONAL PERCOLATION TEST PRIOR TO THE CONSTRUCTION OF THE SEPTIC FIELD. PLEASE SUBMIT STAMPED AND SIGNED RESULTS WITH THE AS -BUILT INSPECTION REPORT. IF THE RESULTS REQUIRE A DESIGN CHANGE, CONSTRUCTION OF THE SYSTEM WILL STOP PENDING ON-SITE REVIEW AND APPROVAL. c— Received By �� Issued By<i Date: Date: Woo Parcel I.D. Municipality of Anchorage Development Services Department Building Safety Division On -Site Water and Wastewater Program 4700 Elmore Road P.O. Box 196650 Anchorage, Alaska 99507 www.muni.org/onsite (907) 343-7904 ON-SITE SEWER/WELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING os l- ala -3o Property owner(s) /71 aft •rd W oon Day phone 46-94.-- S(SS Mailing address /7e33 Jgrt f (eJcy t Ch�41c k -Zip Code 513-07 Site address S4 mss. e ✓ Zip Code Legal description (Sub'd., Block & Lot) Legal description (Township, Range & Section) Lot Size -2 52 Ge1rC° Sq. Ft. /oat oac, 107 L 775n! (Part) S EC zs ,Behr GWS Number of Bedrooms tti'7`Alai Afir= s - THIS APPLICATION IS FOR (® all that apply): THIS APPLICATION IS AN: Absorption Field Septic Tank Holding Tank Privy Private Well Water Storage Initial 19' Upgrade ❑ Renewal 0 I certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and in accordance with applicable Municipal Codes. re of property owner or authorized ag Permit/Rush Fees: .' 3 r1) Waiver Fees: Date of Payment: 7- t/ - O 9 Date of Payment: Receipt Number: 0 _J 0 S C» Receipt Number. _ (Rev. 11/05) TI -RIM kg. NEERING r� July 23, 2009 NorthRim Engineering PO Box 770724 Eagle River, AK 99577 907-694-7028 MOA On -Site Water & Wastewater Program 4700 Bragaw St Anchorage, AK 99519 RE: T15N R2W SECTION 25, BLM Lot 145 Failed Absorption Trench The referenced property has a flooded absorption trench. The design calls for a new trench and new septic tank. Private water wells serve the area and no water well conflicts are present with these large BLM lots. The BLM easements are shown and do not conflict. The powerline corridor lies to the east and northeast. The owner desires to construct this system himself. Another test hole is planned at construction time on the east end of the trench to verify the soil. Please review the wastewater system design for the single family home. I have included design plans & specs, design guidelines, & soil tests. If there is need for additional information or clarification please give me a call. Sincerely, teve Eng, PE, P11 Design Enclosures T15N R2W Section 25, BLM Lot 145 SPECIFICATIONS & DESIGN GUIDELINES Wastewater System Sizing: This is an existing 3 -bedroom, single family home. The absorption bed has failed. A new design is submitted for a new trench & new septic tank. The owner desires a 4 bedroom system + mother -in law apartment. The neighboring lots are large and do not conflict with the new septic system. A new soil test was conducted. A 6' deep trench will be excavated with new 1500 gallon septic tank. The old tank will be removed or properly abandoned in place. Private water wells serve the area lots. No adverse impacts are expected from septic system replacement. The easements are located on the drawing and are not encroached upon. The soil tests revealed a sandy soil. A conventional septic system will be used, application rate of 1.0 GPD/FT2. Trench Length = 750 FT2/5'x 0.58 reduction factor = 87'; 1 linen 87', 3' effective depth. Specification Requirements: All components and work must comply with the Municipality of Anchorage Specifications (AMC) & State of Alaska Drinking Water Regulations and Wastewater Regulations. • Two compartment, 1500 gallon septic tank. Watertight couplings on inlet & outlet. • 5' minimum between the tank and bed. 10' to property lines. • 3' of cover is required for trench; 1" insulation for one foot soil cover may be used. • Tank & solid pipe must be set on well compacted, stable soil. • 4 inch diameter cleanouts with airtight caps are required 1' to 4' from foundation wall, prior to any 90 degree bend in 4 inch line, in each tank compartment, and two adjacent opposing cleanouts between the tank and the absorption field, not more than 10' from the tank positioned to provide cleanout access towards the tank and towards the absorption field. • All cleanouts must extend to at least ground level. • In solid pipe runs, ASTM D-3034 may be used in lieu of cast iron. • Trench to be placed level, minimum of 4' to groundwater, 6' to bedrock from drain -rock. • Drain rock to be 1/2 inch to 2' /2 inch screened. Drain rock to be distributed uniformly throughout the trench. • Perforated pipe to be installed level with perforations down. • Silt barrier (filter fabric) to be installed above the drain rock. • Smeared trench sides must be raked or scarified before drain rock placement. • The finish grade must be mounded to promote drainage over the trench. • Insulation must be placed over any pipe installed under driveways or parking areas. • Approved pipe materials include cast iron, PVC ASTM D3034, PVC ASTM F789, ABS ASTM D2661, • Sewer Service Line is minimum 2% slope. • Septic Tank to be pumped every two years or when required. • Insulation board to be extruded direct burial polystyrene (Dow Styrofoam 111 or equal) • Old Septic Tank to be removed or pumped, filled with sand/gravel, crushed, & buried. DESIGN NOTES: 1. Total Depth of Trench is 6'. Septic Site is on 5% Slope. 2. Sewer Service Line minimum 2% slope. 3. Measure Distance To Well Prior To Excavation. 4. Lots Served by Private Water Wells. \_No Conflicts Powerline Corridor New 1500 Gallon Septic Tank \ Q TH1 \ ` \ Decommission Existing tic Tank Existing Trench L_ BLM 50' Easements James Way Double C.O.'s 5 7. slope NOR MIR 110 ENGINEERING PO Soo 770721 Cogs Rl e , Alaska 99577 907.694. 7028 T15N R2W Section 25 BLM LOT 145 NEW TRENCH/TANK SEPTIC SYSTEM 1' = 50' PLAN LAYOUT talc 7/23/09 l of 3 Foundation Cleanout Monitor Tube v a 0 N 11) nr,(rtw tistwsostit 4.1440.4.0 a; a 0 H L pi L +' 0 Ls L. 0 oxi W v Q + L co u Q, rn U1 d > 0 £ O L E O U S L U ih U C W 0 *3Q Effective Depth 1- 4. a a, 0 v a u u o T d d N + i 4 i 01 a 0473 E U U1 i E 0 7 3 3- 0+' O E rd L. WE LI -ac y+04- SDN L N aS E N VI�`~ N�ti to a _6wS c' U N L J O O o. 0 y0+ dU CS N U N is O LS4.H W LJ 0 cuOI-a cu 0~ NN~ aL L ZL us L Ly O-3 Z a�+d;a3� CU vi gv)Nrn3n¢� a .- ni ri v vi kb R2W Section 25 Z 4. O N 111 3 w A Z W 2 U Z W NEW TRENCH/TANK W J r -y LL O 0 i ail •obi *4 t'421 sic is Near 5% Slope c c L d F q U F - y N n o y d N 3 j N to cz LL -- '.0 ; h N w 3 a +� Cu i'S j 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 S❑ILS LOG - PERC❑LATI❑N TEST THRIM c NEERING Date Performed: 7/16/09 Performed For: Rich Moon Legal Description: BLM Lot 145 DEPTH (FEET) l*'4WZ Organic 19 - 20 SM Silty Sand w/ Gravel Denser 2 •.. Q Depth T.H. Location: See Attached Design Flat Terrain Groundwater? No Depth Water After Depth Monitoring. None 7/a3/o9 Date: "7/20%7 tl Date Gross Tine Net Tine Depth Net Drop 1 7/17 0 -- 5' -- 2 7/17 10 10 nir. 7' 2' 3 7/17 12 -- 5' -- 4 7/17 22 10 nir. 7' 2' 5 7/17 25 -- 5' -- 6 7/17 35 10 nir. 7' 2' 7 7/17 37 -- 5' -- 8 7/17 47 10 nir. 7' 2' 9 7/17 50 -- 5' -- 10 7/17 60 10 nir. 7' 2' 21 Percolation Rate 5 min./inch Perc Hole Diameter 6' Test Run Between 3' and 4' Comments: Presoaked Performed By NorthRim Fng I..$J CERTIFY THAT THIS TEST WAS Performed in Accordance with All State/Municipal Guidelines In Effect ON THIS DATE. DATE: 7/23/09 NORTHRIM y. e.-inc, ENGINEERING * •-9m • * T. H. 1 TESTHILE LIG BLM LOT 145 PO Box 770724 Eagle River. Alaska 99577 Nii:. 907.694.7028 7llGEOTECHNICAL Dote: Plat 7/23/09 I1 1 SIT NICIPALITY OF ANCHORAGE Heali Land Environmental Protect n Fourth Floor West 825 L Street Anchorage, Alaska 99501 279-2511, x 224, 225 /� /�INSP CTION REPORT ON-SITE SS/�EW�AGE�DISPOSAL SYSTEM�'�/ NAME%�h L6}acer6 (MAILING ADDRESS -J ..?.."J_-�_e-_174.9c/ --L">Fi%{ONE 69`J 3� LOCATION L&w� g ri4'4 Ke LEGAL DE. SC R IPT ION L4- A-115-- t/ 11 ®F (-43SEPTIC TANK: DISTANCE ff � �n� N MBER OF FROM WELL.NI ' ___ MANUFACTURER C bSs'--TMATERIAL 'Qt2 1 N9%(bFAPA RTMENTS _! INSIDE LENGTH INSIDE WIDTH__._..'"-._.__ LIQUID DEPTH � —L IOUID CAPACITV6 GALLONS. / / 20 ( TOTAL LENGTH., ---,7 DISTANCE FROM WELL (. FOUNDATION _ __ _NEAREST LOT LINE_...__.. _-____.OF LINE / 1DISTANCE BETWEEN LINES ____9..— TRENCHWIDTHIN. TOTAL EFFECTIVE of Lines -- /��p ABSORPTION AREA �-`/ 50 FT LENGTH OF EACH LINE L5c7 DEPTH OF FILTER / !r DEPTH: TOP OF TILL TO FINISGRADE - -_FINISHMATERIAL BENEATH TILE 6 IN ABOVE TILE ' IN SEEPAGE PIT: DIAMETER OR WIDTH__ ., f_ENGTH__., DEPTI-I Log Crib Rings Crib Size: DIAMETER_.___DEPTH DISTANCE FROM: WELL TOTAL EFFECTIVE ABSORPTION AREA (WALL AREA) BUILDING FOUNDATION NEAREST LOT LINE Well Class: Depth: Well Distance To: Lot Line Bldg: Sewer Line: Pipe Materials: el -a Pe-. # of Bedroomq: Installer: LAW 5pA9 Muon Remarks: SO. FT. f I IIV. 1 I P (� D ATE &_.:72_'(71' ROV ED M 1..-8 I°-4 :E e_ :IC F== f=G 1_-._ T_ - TL- "-a ° c.: ®9- f --e r- e_. a --a c -c t.- rl Ln= - DEPARTMENT 0E -A _FH[_THPROTECTION AND ENVIRONMENTAL PTs'!]T 825 L fTREET: ANCHORAGE, HF:: 995'N,, ° ,,----/- (S'0 . 279-2511 _ A::2L DIN —SI E LJ F° F"a-F.M Y. -Ty-15-77_ PERMIT NO.. C 77679 : APPLICANT HL, H N LOCATION LOWER F I REL.HF:tE LEGAL LT. 145 .E _STi 5F4F W P. O. BX. 594 E. R. 694-2309 LOT SIZE 100000 SQUARE FEET TYPE OF SOIL ABSOR9TION SYSTEM IS: TRENCH • MAXIMUM NUMBER OF BEDROOMS = 3 SOIL RATING t71 F'T/BR) = 230 THE REQUIRED SIZE OF THE: SOIL ABSORPTION SYSTEM IS: I_-• EEO-" 11-1— L. E B°-"1 G -I F-1 !t5E3 e...S F: EI EEF_ F_•• E. F-" -Tr Y-1 — e; THE LENGTH DIMENSION IS THE LENGTH (IN FEET) OF THE TRENCH OR DRA1NFIELD. THE DEPTH OF A TRENCH OR PIT IS THE DISTANCE BETWEEN THE SURFACE OF THE. GROUND:' AND THE: BOTTOM OF THE EXCAVATION (IN FEET). THERE IS NO SET WIDTH FOR TRENCHES. THE GRAVEL DEPTH IS THE MINIMUM DEPTH OF GRAVE... BETWEEN THE OUTFALL PIPE AND THE BOTTOM OF THE EXCAVATION (IN FEET). •Fes° EE ®_:®4_I 1 F- IF=:1D• °_: F= F=" -1_ TC ®^ : -r- F I P-4 F( S 1 r __ E = 1_ el n a e. =-e a a n 1.._._ 1_ e_e r °I F="a=EC F=::F=&GEE F"I_nI'-gi-Y- oF=°-F- 1 e_ef-4 H PACKAGE PLANT MAY BE INSTALLED AT THE E-ERt1ITTEE:'= OPTION SUBJECT TO THE. FOLLOWING CONDITIONS: 1. EITHER H CLASS I OR 11 NSF APPROVED PLANT MAY BE INSTALLED. 2. H CONTINUOUS MAINTENAFdf:E AGREEMENT IS REQUIRED. IF H MAINTENANCE AGREEMENT IS NOT KEPT CURRENT YOU MAY BE REQUIRED TO ENLARGE THE :=OIL._ ABSORPTION SYSTEM AND/OR YOLI MAY E:E SUBJECT TO PROSECUTION. 1.".1 C) •_: _ :-• T: 1°4 55 F=° rE IC 1-3: CD Y-.15 h=1 F°IFE FP° FE c'e 4_c :1: R F= I :_• — — - BACKFILL.ING OF ANY SYSTEM WITHOUT FINAL INSPECTION AND •APPRO'/AI_. BY THIS DEPARTMENT WILL BE SUBJECT TO PRO-SECUT1'JN. MINIMUM DISTANCE BETWEEN H WELL AND ANY ON-SITE SEWAGE DISPOSAL_ SYSTEM IS 100 FEET FOR H PRIVATE WELL OR 2001 FEET FOR A PUBLIC WELL. OTHER REQUIREMENTS t'1HY APPLY. SPECIFICATIONS AND COONSTRUC:TION DIHGF:AI'15 HF:E AVAILABLE TO INSURE PROPER INSTALLATION. F=° FE F' N1 1 t F -:w" f=" _d F_° E.. F. • F-.. c__ E. F°7 F-= F-_ F. 1 T CERTIFY THAT 1: 1 AM FAMILIAR WITH THE REQUIREMENTS FC'R ON-SITE SEWERS AND WELLS AS SET FORTH BY THE MUNICIPALITY OF ANCHjRA'3E. i'.: T. WILL.. INSTALL THE SYSTEM IN ACCORDANCE WITH THE CODES. 3: I UNDERSTAND THAT THE ON-SITE SEWER SYSTEM MAY REQUIRE ENLARGEMENT IF THE. RESIDENCE IS REMODELED TO INCLUDE MORE THAN 3 BEDROfrt'IS. APDL 1 CAI` ISSUED BY i" AL LARSO !N Y- 0 ^0 Et E GEOT CHNI CAL Et DEVELC.�MENT CO. Russell Oyster 694-2774 Soils & Foundations Box 90, Davis St., Eagle River, Alaska 99577 694-2774 or 688-2280 SOIL LOG Earl El/is 688-2280 Land Development Performed for: Name: ,4L Lasa,,./ Tel. No. Vii' " -°0i Mailing Address: Rc9.Sox: 671, E,twt Eit/,ct, /Mr, ?5'377 Legal Description: Lot" 467, 5,re-25`, 776-M; ,e2W, Depth (feet) Soil Characteristics 0 1 Aft 6/4, y- p .' 2 3 5 6 7 8 9 10 11 12 13 sorrow/ o/C 14 yPct Cr ia3'T /J(4,1 s' rc 4750.47 t't £4,efoy vis F,Q5 p /.f/ Rican; .%.tl) 2 e -ds 5L k W'7`,v/A! 4 leai 7:t/n y -5214407 6,CG4dez . Per ei iT 15 16 Ground Water Encountered: Yes No V- If yes, what depth Proposed Installation: Seepage Pit Drain Field Comments: ;30 04,,. '7744 /119cg$ hr?e t! %';ems /emit; :rt e 2 &D 1/5, 7 Performed by: atm Date: ,i//3/77 M -W DRILLING, INC: C MUNICIPALITY OF ANC1I0P 0 DEPT. OF 11EA;SH P. JUN DRILLING LOG Well Owner iaa V. Use of Well Da' 1. Location (address of: Township, Range, Section, if known; or distance main road L,>1 1'-15 "T15N i? 4.1 S7 Size of casing Depth of Hole -'0 feet Cased to 103 • 35 feet Static water leve] ft (above) (below) land surface. Finish of well (check one) open end ( ); Screen ( ); Perforated ( ). Describe screen or perforation_ td/A Well pumping test at ,• gallons per- (hour) (minute) for hours with— ft of drawdown from static level. Date of completion / WELL LOG Depth in feet from ground surface Give details of formations penetrated, size of material, color and hardness TO (;3.3 is.r*, st:i6kuD ] TO > OTcgantcs Q TO 2.11 Silty gravel; cohhly TO 2g 2 TO TO a0 50 TO TO 7.0 Sand Silty Sandy "v01 Sandy lJv .1. hard an :1.00 TO 150 - q-ce2n ba(M)dc, no UaLrar TO TO TO TO TO 2 --STATE Parcel I.D. (907) 343-7904 CERTIFICATE OF ON-SITE SYSTEMS 051-312-47 Expiration Date: /0 "~ c~ _/_Oz.- '1. GENERAL INFORMATION Complete legal description Alta's View Lot 2 Location (site address) 17833 James Way, Eagle River, AK Curreht Property owner(s) Rich Moon · Mailing address same · Rea ,;Estate Agent ' Owner 2. TypE: ~I?D'WELMNG: Day phone 223-2449 Day phone 223-2449 Single Family (w/we ADU) Duplex Multiple Dwellings (Single Family and/or Duplex) NUMBER OF BEDROOMS: TYPE OF WATER SUPPLY: Individual Well Individual Water Storage Community Class C Well Public Water System 5 TYPE OF WASTEWATER DISPOSAL: Individual [] Holding Tank [] Community [] Public Sewer [] Received by: ~--~---~-~ COSA to be released tO the engineer, unless otherwise requested by the engineer. Date: ~7/ COSA Fee $ Date of Payment Receipt Number COSA # Date: Date of Payment Receipt Number Waiver # 5. STATEI~T~)~PECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further vedfy that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm NorthRim Engineering Phone 694-7028 Address PO Box 770724, Eagle River Engineer's Printed Name 6. DSD SIGNATURE Steve Eng 'v" System #1 Approved for System #2 Approved for Disapproved. Conditional approval for Date 7/22/2015 .a,-'~. .' .~, %'"r ~. bedrooms. ~ ...~:.~7_~ :.~.- ~ bedrooms, with the following stipulati~~ ~ WASTEWAIt:R ~ --';.'~.-,,. PROG R.A.~,'I By: Ox_~/~~ ~.-/~ Original Certificate Date: 7' ~ ~:~- /~' The Municipalit:~,~,~,,,,.,,,.,rage Devlopmen ervices ivision ( ) ssue upon the representations given in paragraph 5 by an independent professionai civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: COSA Checklist Septic System Advisory Well Flow Advisory COSA blue sheeLg-l-12.doc X Nitrate Advisory Arsenic Advisory Other If more than 1 septic system is on the lot: COSA Checklist # of Structure serw~:l by this system __ Certificate of On-Site Systems Approval Checklist LegalDescription: ~J''7--~'~(,,¢ ~//'~---f,4.) ,/0'7-- ~' A, WELL DATA Well type p IfA, B. or C provide PWSID # Total depthd ~:~ ft. Cased to/~-,/. ~$ft. Parcel ID: (:3SI- ,.~fZ'- z.( 7 Well Log (Y/N) '~/ Wires properly protected (Y/N) y Casing height (above ground) /2 in. FROM WELL LOG Date of test ~'/~ ~/'7 7 Static water level " ft. Well product[on ~ g.p.m. AT INSPECTION ~2. o ft. (:3. ~.~' g.p.m. WATER S. AM~LE RESULTS: Coliform" (~) colonies/100 mL Nitrate .,~, ~'-~ mg/L Arsenic Collected by: /v/-~f,,~ ~",~ B. SEPTIC/HOLDING TANK DATA Tank size /.,,~0 gal. NumberofCompartments Foundation cleanout (Y/N) _7~7 Depression over tank (Y/N) C, ABSORPTION FIELD DATA Date insta!led~ Soil rating (g.p.d./ft2 or ~/bdrm) Date installed Cleanouts (Y/N) High water alarm (Y/N) SYstem type Gravel below pipe Total_.~/ej.91dePth. ~1~ ff. ,.. E, ffi~absorption area 7'~¢¢ ft2 Monitoring tube ~ Depression over field ~teofadeqUaCy. te~,~*/~ ~e,~Its(P~ssIF~,,) ~ - For ~ bedrooms ~[uiddepth¢:~'¢~?~bn~%~eforetest ~ in. Wateradd~ 7~¢.gal. Newdepth ~ in. ElaPse~.Tim~~~~ Final fluid depth ¢ in. AbsorPtion ',.: ......-'~,~' ,/~ Any rejuv¢~natJaq $¢;~t (past 12 mo.) (Y/N & type) ~ If Yes, give date D. LIFT STATION ,4J/~' Date installed "Pumo on" level at Datum Size in gallons "Pump off" level at n. Cycles tested Manhole/Access IY/N) High water alarm level at Meets alarm & circuit requirements? SEPARATION DISTANCES WELL ON LOT TO: Septic tank/lift station on lot Absorption field on lot Public sewer main Sewer/septic service line Animal containment areas /00 SEPTIC/HOLDING TANK ON LOT TO: Building foundation //G Water main // Wells on adjacent lots ABSORPTION FIELD ON LOT TO: Proper~y line Water Service line Curtain drain On adjacent lots / ~ f~ On adjacent lots / 0 o ~ Public sewer manholelcleanout ,/'~ O Holding tank /,~ ~ Manure/animal excrete storage areas Property line /0 /'f- Absorption field ~" Water service line / ~ ~'f- Surface water /~0~/"/"' ,/~' r'4' Building foundation /' 0 re... Water main . Surface water /~ O "~" Driveway, parking/vehicle storage ~' G ~'~' Wells on adjacent lots ,/~ O ff' COMMENTS ' G. ENGINEER'S CERTIFICATION I certify that I have determined through field inspections and review of Municioal records that the above systems are in conformance with MOA COSA guidelines in effect on this date. Engineer's Printed Name ~" ~--/¢'...-'~/~ ~'~L/~ Date '~/ ~2/ /-'~ COSA yellow sheeL2-6-15.doc Municipality of Anchorage Development Services Department Building Safety Division On-Site Water and Wastewater Program 4700 Elmore Street P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907) 343-7904 Water Well Advisory Certificate of On-Site Systems Approval (COSA) # 1513 72 During a recent COSA on-site inspection and test of the potable water supply well on Block , Lot 2 of Alta's View subdivision, the well's productivity was determined to be 0.55 gallons per minute. The minimum well productivity required by this Department (AMC 15.55) for a 5-bedroom residence is 0.52 gallons per minute. Although the subject well currently exceeds this minimum requirement, all parties concerned are advised that the production capacity of the well may fluctuate. Restriction of non-critical water uses such as washing cat's and watering lawns and gardens may be required. This advisory must be attached to all copies of the subject Certificate of On- Site Systems Approval. LOT 140 LOT 1 OLM ROAD RESERVATION (LOT 145) OLD SEPTIC TEST HOLE% LOT 2 "~ LOT 1 46 CANT / / JAMES WAY MUNICIPALITY OF ANCHORAGE DIVISION OF ENVIRONMENTAL HEALTH DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION APPLICATION FOR HEALTH AUTHORITY APPROVAL CERTIFICATE 1. General Information Application Date (a) Legal Description (include lot, block, subdivision, se tion, township, range) Lo2Y-11 /cants Name (b) Ap tion (address or directions) dal 9 4.2_)gci„. Telephone - Home Business Applicants address (c) Applicant is (check one) Lending Institution ; Owner/builder IX 1 ; Buyerrr---7 ; Other (explain); (d) Lending Institution Address Telephone (e) Real Estate Co. & Agent Address (i'O. 15/7 Telephone (f) Mail the '9c/-• 93 7 —/77, 4 %'/'r>soI HAA to the/following address: C OA/ cT `/a 6-0LA" 2. Type of Residence Single -Family I 1 Number of Bedrooms Multi -Family dr 3. Water Supply - Individual Well Community Other (describe) Public Ii Note: If community well system, must have written confirmation from the State Department of Environmental Conservation attesting to the legality and status. 4. Sewage Disposal Onsite Public Community FT Holding Tank pi Note: If community well system, must have written confirmation from the State Department of Environmental Conservation attesting to the legality and status. [Page 1 of 2] 5. Engineering Firm Providing Inspections, Tests, File Search, Data and Information As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation of this Health Authority Approval shows that the on-site water supply and/or wastewater disposal system is safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that, based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is in compliance with all Municipal and State codes, ordinances, and regula- tions in effect on the date of this inspection. Name of Firm Address ea :' ` NOINE RiNC3 3?.'r 9 0}t u,-,aLsi RIVFr1. PH, ALASK1,�,57:dSp/ 617 Date 69V107'-S7J f7 6. DHEP Approval Approved for Approved bedrooms (ENGINEER SEAL) Telephone ,e`� ssOF .q 4. !1 i�P'." •�S4b ami. 911 ,• Robed A. Skater ;S"'.• No. lur-E da]AaFa.......•..•' ���,�`�. By arc/E./San-Jr ®� pROFEESION� /4fj� Date �`®�vru.•a'�~r, Disapproved Conditional Terms of Conditional Approval CAUTION THE MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION (DHEP) ISSUES HEALTH AUTHORITY APPROVAL CERTIFICATES BASED SOLELY UPON THE REPRESENT- ATIONS GIVEN IN PARAGRAPH 5 ABOVE BY AN INDEPENDENT PROFESSIONAL ENGINEER REGISTERED IN THE STATE OF ALASKA. THE DHEP DOES THIS AS A COURTESY TO PURCHASERS OF HOMES AND THEIR LENDING INSTITUTIONS IN ORDER TO SATISFY CERTAIN FEDERAL AND STATE REQUIRE- MENTS. EMPLOYEES OF DHEP DO NOT CONDUCT INSPECTIONS OR ANALYZE DATA BEFORE A CERTIFICATE IS ISSUED. THE MUNICIPALITY OF ANCHORAGE IS NOT RESPONSIBLE FOR ERRORS OR OMISSIONS IN THE PROFESSIONAL ENGINEER'S WORK. RR4/ej/D18 [Page 2 of 2] (DHEP SEAL) 7-19-84 n n • MUNICIPALITY OF ANCHORAGE (MOA) HEALTH AUTHORITY APPROVAL (HAA) CHECKLIST - FEBRUARY 1984 MUNICIPALITY OF ANCHORAGE DEPT. OF HEALTH & ENVIRONMENTAL PROTECTION 'AUG 31984 RECEIVED A. WELL DPSTA Well Classification 5, 17 If A, B, or C, D.E.C. Ap roved(Y/N) Well Log Present N) Date Completed 5-19/97 97 Yield .1-6P,774 Total Depth /5 0 t Cased to /733,83-t Depth of Grouting i Static Water Level 85 Pump Set At a le, Casing Height Above Ground 2St Sanitary Seal on Casing (aN) Electrical Wiring in ConduitAN) 'N) Depression Around Wellhead (Y/N) Separation Distances from Well: /60 i To Septic/Hg Tank on Lot To Nearest Edge of Absorption Field on Lot ��� • On Adjoining Lots /Op /-1- ; On Adjoining Lots /Zk) /I To Nearest Public Sewer Lie A - Water Sample Collected By ,5 c5 CN Cleancut/Manhole c� To Nearest Sewer Serve Line on Lot 80 �?. ; Date `7� I26V �1 5frES-7i� it e� Comments � G�E�t� ��--rev,) "T�i S � F=o -7-74,c; 1./F ---L c TC T ie -DD 0Ct' /A/ exce or 9$Gv°rr9 4r O z //UG ry r/t• o AIeg reer Asak'fls e tv.em-re 4 r �a free B. SEPTIC/ G TANK DATA/ pe,40acc 6c/ 1?- , Date Installed 646o///77 Size /0e0 No. of Compartments 2 - To Nearest Public Sewer Water Sample Test Results Standpipes(OIT) Air -tight Capse 9/N) Foundation Cleanout QN) Depression over Tank (Y 7 Date Last P d6?////6154 Pumping/Maintenance Contract cn File (Y/N) //Q ; for `�j Holding Tank High -Water Alarm (Y/N) 4/4 Temporary Holding Tank Permit (Y/N) 2 Separation Distances from Septic/Hutd5PAg To Water -Supply Wall A10 To Property Line To Water Course Comrents Main/Service Line N Tank: To Building Foundation To Disposal Field /0 To Stream, Pond, Lake, or Major Drainage [Page 1 of 2] 2-15-84 C. ABSORPTION FIELD DATA Soils Rating in Absorpt'on Strata 2-30) 42-- Type of System Desion /g6 -AKIN Date Installed 6/77 Length of Field 9 Width of Field tD Depth of Field Gravel Bed Thickness 7z Square Feet of Absorption Area 69b li Standpipes Present MIN) Depression over Field (Y ) Date of Last Adequacy Test 8/l / g q Results of Last Adequacy Test >/777.$',CAc 7z n ,/ f&.)t / ,5EQ' Separation Distance from Absorption Field: To Water -Supply Well To Building Fo ndation Lot �7/a- To•Water Main/Service Line On N To Property Line /p Cr To Existing or Abandoned System cn 30 -/- joining Lots To Stream/Pond/Lake/or Major Drainage To Driveway, Parking Area, or Vehicle Cucments To Cutbank(i present) Course Storage Area Bo D. LIFT STATION Date Installed Dimensions Size in Gallons Manhole Access (YEN) ".Pump On" Level at „ /"Pump High Water Alarm Level at Tested for Pumping Coles diming Adequacy Test. Meets MOA Electrical Codes(Y/N) / ,q f" Level at Vent (Y/N) Colmnents ** ** Check Permitted Bedroom Rating Against HAA Request I certify that I have checked, verified, or on the date of this inspection. 8 & ENGINEERING qRu 190X I Vr.G .E RIVER. ALASKA 'DOW/ PH, s94a?979 Signed Company KB1/d5/s [Page 2 of 2] conformed to all MOA HAA Guidelines in effect 2-15-84