HomeMy WebLinkAboutMONASTERY LT 2Mona, ,ery Lot 2 #051-302-77 SUBMITTAL Municipality of Anchorage IAN 1 2 Z° Community Development Department Page 1 of 2 On-Site Water and Wastewater Program 4700 Elmore St. • P.O. Box 196650 Anchorage, AK 99519-6650 • http://www.muni.org/onsite • (907)343-7904 ON-SITE WASTEWATER INSPECTION REPORT Permit Number: OSP151255 PID Number: 051-302-77 [' New 0 Upgrade Name: James & Delores Patras ABSORPTION FIELD Address ❑ Deep Trench ❑ Shallow Trench ❑ Bed ❑ Mound 19216 Monastery Dr. ❑ Other Phone Number of Bedrooms Soil Rating Total depth from original grade 6 GPD/SF Ft. LEGAL DESCRIPTION Depth to pipe invert from original grade Gravel depth beneath pipe Subdivision Block Lot Ft. Ft., Monastery 2 Fill added above original grade Gravel length Township Range Section Ft. Ft., Gravel width Beds:Number of Lines Distance between lines SEPARATION DISTANCES Ft. Ft. To Septic Absorption Lift Station Holding Sewer Total absorption area Number of trenches Dist.between trenches From Tank Field Tank Line Ft2 Ft. Well 120.8 N/A 100+ 75+ 1 118.4* TANK CI Septic 0 S.T.E.P. 0 Holding CI , Manufacturer Capacity Surface Water 100+ N/A N/A N/A Anchorage Tank • 2,000Gal. Material Number of compartments Lot Line 50.0 N/A N/A N/A Steel 2 NA LIFT STATION Foundation 11.5 N/A N/A N/A Manufacturer Capacity Curtain Drain 50+ N/A N/A N/A Gal. Pump on level at Pump off level at High water alarm at Remarks*Distance only measured to new sewer line. in. in. in. Only installed new tank. Pump make and model Electrical Inspections performed by PIPE MATERIAL House to tank 3034 Tank t3034 Installer drainfield JR's Septic Drainfield 3034 CO/MT 3034 Inspector Pannone Engineering Services, LLC. BENCH MARK (Assumed elevation) 100 ft Inspection 1� 9/9/2015 �a Location and description dates: 2 3rd 4th Top of Deck COMMUNITY DEVELOPMENT DEPARTMENT APPROVAL Engineer's Stamp Conditional Approval: Dateter:. ..'• ...4.0_, i, %* I *t? .1 ••*40).4e , / ''b'teven IA. annorae O -V.. CE 814-,9,' .*,off Appr. • -.�` ._. .. 1s �■r+ Date7 Z1'1 co Ii`i'r`Dy .4 q ...• Inspection Report_1-1-12.doc SPECIAL PROVISIONS TO SPECIFICATIONS ALL CONSTRUCTION WAS INSTALLED AS SPECIFIED IN THE MOST CURRENT EDITION OF THE MUNICIPALITY OF ANCHORAGE STANDARD SPECIFICATIONS (MASS) FOR COMPONENT PARTS AND MATERIALS USED IN CONSTRUCTION OF ON-SITE WASTEWATER DISPOSAL SYSTEMS. 2. SCOPE OF WORK: INSTALLED NEW 2,000g SEPTIC TANK AND ABANDONED EXISTING TANK PER CODE. 3. BASED ON PERIODIC FIELD OBSERVATIONS AS REQUIRED BY AMC 15.65 THIS RECORD DRAWING REPRESENTS THE PROJECT AS CONSTRUCTED, BUT DOES NOT GUARANTEE THERE ARE NO HIDDEN DEFECTS BY THE CONTRACTOR. A B MONESTARY DRIVE o; 7 7 5 Ti 18.90 31.10 0 T2 23.30 39.30 zw w mZ DC 25.70 42.10 20' BLM EASEMENT 0` U - - 97.5 � SEPTIC AREA (E) '�M 20' T&E EASEMENT 92.9-'--- 2000g SEPTIC '_�` - \ TANK NEW ,0, TANK • \\c6- q . \ . 1750g SEPTIC I ANK \ / ABANDONED PER CODE \ti INSTALLED NEW 2000g SEPTIC TANK 6BR -10go TANK MAX BURIAL DEPTH 7' ' A DUPLEX WITH DOUBLE CLEAN OUT i /1- 11100.. (E) 1 I 621 Ii M�M DECK B M M , __AA —_ WELL (E) I FC (E) /DC T2 __.•--3 • - 1 WELL (E)— \ / \ DRAIN FIELD (E) \ 44 w� ., \ LOT 2 \i•-. ,0 . I___c_,,__. _IV DRAIN FIELD (E) ��\ � SERVES 62B SEPTIC EASEMENT—�� NI DESIGN PARAMETERS ABBREVIATIONS INSTALL NEW TANK LEGEND FC FOUNDATION CLEAN OUT NO. BEDROOM: 6 T# TANK CLEAN OUT NO. TANK SIZE: 2000g STEEL W WATER LINE/ C# CLEAN OUT NO. WELL RADIUS DCO DOUBLE CLEAN OUT USED: OG ORIGINAL GRADE NEW 2,000g STEEL SEPTIC TANK SS NEW SEPTIC E EXISTING NOTES: PANNONE ENG SVC, LLC ,.�.��� Date RECORD DRAWING P.O. BOX 100217 ANCHORAGE, AK 99510 S'<� ...oF A�,4s11+ 1/7/2016 �•P'• '� Scale PHONE (907) 272-8218 FAX (907) 272-8211 -'ro.• y DRAWN BY: %*.' 49 T}i * j 1"=5°' NJC •••• •" ' / P.I.D. NO -- MONASTERY, LOT 2 .. P. ... 51-302-n JAMES & DELORES PATRAS d Steven R. Ponnone j PERMIT NO. i)• CE 8149 .'� OSP151255 19216 MONASTERY ROADr PLAN EAGLE RIVER, AK 99577 O11J-At. • Np�`�,*�' Sheet l P4 f ``'C�'�' 2 OF 2 On-Site Water and/or Wastewater System Permit o e n t s MUNICIPALITY OF ANCHORAGE Development Services Department On-Site Water&Wastewater Program 4700 Elmore Road, PO Box 196650 Departtnent Anchorage,AK 99519-6650 Telephone: (907) 343-7904 / Permit Number: OSP151255 9 J `q— 1� ` Tax Code Number: 05130277000 Work Type: SepticTank Upgrade Permit Effective Dates: August 13, 2015 to August 12, 2016 Design Engineer: PANNONE ENGINEERING SERVICE Subdivision: MONASTERY Site Legal Address: MONASTERY LT 2 G:0655 Owner/Address: PATRAS JAMES B & DOLORES A 50% & DYAL REVOCABLE TRUST 50% DYAL J R & P PO BOX 770135 EAGLE RIVER AK 995770135 Site Mailing Address: 19216 MONASTERY DR, Eagle River Lot Size in Sq Ft: 53865 Total Bedrooms: 6 This permit is for the construction of: N Disposal Field Y Septic Tank N Holding Tank N Privy N Private Well N Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80). 3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either: A. Open and Close on the same day. B. Covered, sealed, and heated to prevent freezing. • Received By: Date: L U 1 Issued By: e1/ ,/ 1/. 17 Date: Allir Permit Number: Tax Code Number: Work Type: On-Site Water and/or Wastewater System Permit OSP151255 05130277000 SepticTank MUNICIPALITY OF ANCHORAGE Development Services Department On-Site Water & Wastewater Program 4700 Elmore Road, PO Box 196650 Anchorage, AK 99519-6650 Telephone: (907) 343-7904 Upgrade Permit Effective Dates: August 13, 2015 to August 12, 2016 Design Engineer: PANNONE ENGINEERING SERVICE Subdivision: MONASTERY Site LegalAddress: MONASTERY LT 2 G:0655 Owner/Address: PATRAS JAMES B & DOLORES A 50% & DYAL REVOCABLE TRUST 50% DYAL J R & P PO BOX 770135 EAGLE RIVER AK 995770135 Site Mailing Address: 19216 MONASTERY DR, Eagle River Lot Size in Sq Ft: 53865 Total Bedrooms: 6 This permit is for the construction of: N Disposal Field Y SepticTank N Holding Tank N Privy N Private Well N Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80). 3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either: A. Open and Close on the same day. B. Covered, sealed, and heated to prevent freezing. Issued By: . MUNICIPALITY OF ANCHORAGE Community Development Department Development Services Division On-Site Water & Wastewater Program Phone: 907-343-7904 Fax: 907~343-7997 ON-SITE SEWER/WELL PERMIT APPLICATION Parcel I.D. 051-302-77 Property owner(s) James & Delores Patras Mailing address P.O. Box 770135, Eagle River, AK 99577 Day phone Site address 19216 Monastery Drive Legal description (Sub'd., Block & Lot) Monastery, Lot 2 Legal description (Township, Range & Section) Lot Size 53,865 _Sq. Ft. Number of Bedrooms 6 APPLICATION IS FOR: ([~ all that apply) Absorption Field [] Septic Tank [] Holding Tank [] Privy [] Private Well [] Water Storage [] APPLICATION IS AN: Initial [] Upgrade [] Renewal [] TYPE OF DWELLING: Single Family (SF) (w/wo ADU) Duplex (D) Multiple Dwellings (SF and/or D) THIS APPLICATION INCLUDES A VARIANCE I WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certifl/that this is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit/Rush Fees~ Date of Payment: Receipt Number: ~r~ I~. ¢-.~ - Permit NO. 0~',',~ ~) 1 6 [ ~-,0"~ Waiver Fees: Date of Payment: Receipt Number: Waiver No. Permit App_£- :. :'._.,Z¢; Pannone Engineering SerVices LLC Steven R. Pannone, Principal Regigtered Professional Engineer E-maih steve(~panengak.com August 10,2015 Subje~: Monastery, Lot 2 Septic Tank Replace Permit Request Design Narrative This is a design narrative'for a permit to install an upgrade 2000g Septic Tank to be issued for this property. The existing 17500g tank is collapsing and the pumper H-as been pulling rocks from the tank. It will be decommissioned per code. Currently the lot is developed. The proposed system will utilize a replacement 2000g septic tank that will be connected to the existing drain field. This lot and the lot to the east are served by a class 'C' well. The remaining surrounding lots are served by private wells. There are no wells within .~feet of thi~ system. The class 'C' well is over ~L50' from this system. Upgrade Tank Design. a. See Sheet 1of the design package. 2. Surface Water: There is no surface water within 100 feet of the pr-oposed septic tank. The proposed septic tank upgrade will maintain at least 100 feet from all surface water and drainage ditches. 3. Topography: Tt~e existing topography is flat with slopes less than 1% in the vicinity of the system, with a 15%-20% slop to the north and east. The proposed installation will not affect the future development of the surrounding or existing lots. There are no surrounding wells within :~00 feet of the proposed septic location. Mailing: P.O. Box 100217, Anchorage, AK 99510-0217 Physical: 332 East Manor, Anchorage, AK 99501 Telephone: (907) 272-8218 FAX: (907) 272-8211 MONESTARY DRIVE I ' 20' ELM EASEMENT DECOMMISSION PER C~%~ % ~ // ~ iNSTALL 20009 SEPTIC TA~ (P) ' k /} ~ % ~ . -~og~ TANK MAX BURIAL DCPTH~E~% 68R ~ ' WITH DOUBLE CLEAN OUT % / ~ BIIPI F~ ELL(E)- %/' >. % ~¢~ ~,OR CLEAN OUT ' WELL(E)- ~ ~k~ SERVES 62B TANK REPLACE P.O, BOX 100217 ANCHORAGE, AK 99510 ~.' MONASTERY, LOT 2 ~ 051-302-77 JAMES ~ DELORES PATRAS 'f~¢~E¢o~ ~ERMiT NO. 19216 MONASTERY ROAD *~i~'. .'&~ 3SP151255 PLAN EAGLE RIVER, AK 99577 STATE OF ALASKA · DEPARTMENT OF ENVIRONMENTAL CONSERVATION APPROVAL OF ON-SITE RESIDENTIAL WATER AND SEWER SYSTEM pROPERTY DESCRIPTION :rllltcale Issued for Application NO.: This approVal does not constitute a guarantee of any kind, explicit or implied, as to the performance of the water supply and wastewater disposal systems. A recent water sample was t~ Department of Environmental Conservation drink- lng- Water standards f°r t°~~  WASTEWATER DISPOSAL The domestic wastewater system was: [] Inspected by the Department of Environmental Conservation and found to be in compliance with applicable requirements of 18 AAC 72; /~lnspected by a Professional Engineer who certifies that the system complies with applicable re- quirements of 18 AAC 72; [] installed by a Certified Installer who certifies that the system complies with applicable requirements of 18 AAC 72; or [] tested by a Professional Engineer who certifies that the performance of the system is satisfactory and that the system complies with the minimum separation distances specified in 18 AAC 72. This approval Is valid for a [] single family/~ multi-family unit with a total of_ ¢ bedrooms. 18.0404 {REv. 8~5l ; 8087 DEC 21987 DISTRIBUTION: WHITE--BANK/LENDING INSTITUTION; CANARY--APPLICANT; PINK--DEPARTMENT -, ~,~ MUNICIPALITY OF ANCHOFIAGE -~m~b'l~~-'~'}'~' DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION ..{~:~~, E NVIRONMENTALENGINEERINGDIVISION 825 L Street- Anchorage, Alaska 99501 Telephone 264-4720 ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTIQN REPORT UPGRADE MAILI~ ~DRESS ~_ LEGAL D~CRIPTION - ~ ' ~ Manufacturer /OO~ IA~°rpti°n area Dwell,~ PER.NO. ~ ' IMatg~ial .~ ~ No.~ompartments "~ :Liq/a~3gall°ns IF HOME=DE: lns,delengt~ Widt,{ Liquid depth  ~ DISTANCE TO: Well Dwelling PERMIT NO. ~E~ Manufacturer Material Liquid capacity in gallons ~ ~'STANOE TO: WBH7 /00 ~ You~Oat'~~ NBa~,o)jl~ PERM,T NO, Lengt.~ac~ne ~~'~ No. of lin~ ~ ~' ~ta~Eb?~ I.~. Tre~h~Ot,~. -- Distanc~;~en~ ~ Top of tile'to finish grade~. ' ...... j Material ~n~th'{iie ~ ~~/ /~ inches T° t a ~~5*t ~e~ Length W~dth Depth ~ ~ Type of crib Crib diameter Crib depth Total effective absorption area ~ Well Building foundation Nearest lot line ~ DISTANCE TO: ~ Class Depth Driller Distance to lot line PERMIT NO. ~ Building foundation Sewer line Septic tank Absorption ~rea(s) ~ DISTANCE TO: OTHER SOIL ~EST RATING ' ~ ........ I--~ -- INSTALLER : ~~ , _ ' ',X_ ,' ~ , ~ ~, ,, I APPROVED -- ~'~'~''2-''~ DATE LEGAL 72-013 (Rev. 3~78) Permit ~ Applicant: ~~O~ ~. ~/~ a Location: ~15--~ ~ I&O ~%C ~ Legal Description: ~A~/~,%/'L~ Type of Soil Absorption System Is: MUNICIPALITY 0F ANCHORAGE Department Health and Environmenta' 'rotection 825 ~ Street, Anchorage, AK. ~501 264-4720 ~ ~ ~ ~ HANDWRITTEN PERMIT ~ ~ ~ WELL AND/OR ON-SITE SEWER PERMIT Mailing Address:~D~d~/~3 Phone Number: The length dimension is the length(in feet) of the trench or drainfield. The depth of a trench or pit is the distance between the surface of the ground and the bottom of the excavation(in feet). There is no set width for trenches. The gravel depth is the minimum depth of gravel between ~.k~. outfall Pipe and the bottom of the excavation(in feet). ~ ~ REQUIRED SEPTIC(HOLDING) TANK SIZE = Permit applicant has the responsibility to inform this department during the installation inspections of any wells adjacent to this property and the number of residences that the well will serve. * * * TWO(2) INSPECTIONS ARE REQUIRED Backfilling of any system without final inspection and approval by this department: will be subject to prosecution. Minimum distance between a well and any on-site sewage disposal system is 100 feet for a private well or 150 to 200 feet from a public well depending upon the type of public well. Minimum distance from a private well to a private sewer line is 25 feet and to a community sewer line is 75 feet. Well logs are required and must be returned to this department within 30 days of the well completion. Other requirements may apply. Specifications and construction diagrams are available to insure proper installation. * ~ ~ PERMIT EXPIRES DECEMBER 31, 1 9 8 3 * * * I certify that: (1) I am familiar with the requirements for on-site sewers and wells as set forth by the Municipality of Anchorage. (2) I will install the system in accordance with codes. (3) I understand that the on-site sewer system may require enlargement if the residence is remodeled to include more that 3 bedrooms. Signe~: ~o~ ~_ ~~~ Issued by: Date: Trench: ~/ Drainfield: S__~eepage Bed: Holding Tank: Maximum Number of Bedrooms: ~~-IK~ Soil Rating(sq.ft/br) The Required Size of the Soil Absorption System Is: DEPTH ~' LENGTH ,,~?~,1 GRAVEL DEPTH '"/' WIDTH 30 6 glib- 300 I Lot Size: " MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION 825 g Street, Anchorage, Alaska 99501 264-4720 SOILS LOG -- PERCOLATION TEST ~' SOILS LOG [] PERCOLATION TEST LEGAL DESCRIPTION:; 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 19 2O COMMENTS SLOPE WASGROUNDWATER fL! ~'3 i ENCOUNTERED? ~ , IF YES, AT WHAT DEPTH? SITE PLAN Gross Net Depth to Net Reading Date Time _~, ~i ~T?me Water Drop ~Lo~n~e C. ' ~ - PERCOLATION RATE TEST RUN BETWEEN FT AND PERFORMED (minutes/inch) _DATE:~ 72-008 (6/79)