MUNICIPALITY OF ANCHORAGE
On -Site Water & Wastewater Program
Po Box 196650 4700 Elmore Road
Anchorage, Alaska 99519-6650 Phone: (907)343-7904 Fax: (907)343-7997
http://www.muni.org/onsite
On -Site Water System Permit
Permit Number: OSP211126
Work Type: Well Upgrade
Tax Code Number: 05109228000
Site Legal Address: T15N R1 W SEC 8 LT 53 G:1357
Site Mailing Address: 20671 OLD CRANBERRY DR, Chugiak
Owner: ANLIKER BLAINE
Design Engineer: NORTH RIM ENGINEERING
This permit is for the construction of:
❑ Disposal Field ❑ Septic Tank ❑ Holding Tank ❑ Privy
Effective Date:
Expiration Date
,�cnc
°Ltir S� f
a
c C,
Department
Lot Size in Sq Ft
Total Bedrooms:
5/512021
515!2022
0 Private Well ❑ Water Storage
All construction shall be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80)
3. The wastewater code requires inspections during the installation. The engineer shall notify the Development
Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (2417).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
shall be either:
a. Opened and Closed on the same day, or
b. Covered, sealed, and heated to prevent freezing
Special Provisions:
y To close out this permit, please submit the following:
f 1. Well log
c
2. Pump install log
s
j k 3. Water sample results for total coliform, nitrates and arsenic
f, 4. If the original well will not remain in use, it shall be decommissioned and a decommissioning log submitted to
i Onsite.
Received By: Date: S /
Issued By: Date:
MUNICIPALITY OF ANCHORAGE
Development Services Department ;'.A - Phone: 907-343-7904
On -Site Water & Wastewater Section Fax: 907-343-7997
ON-SITE SEPTIC/WELL PERMIT APPLICATION
Parcel I.D. 051-092-28
Property owner(s) ANLIKER BLAINE
Mailing address 20671 Old Cranber
Site address same
Day phone 529-0193
Legal description (Sub'd., Block & Lot) T1 5N R1 W SEC 8 LT
Legal description (Township, Range & Section) 11 II
Lot Size 108,900 Sq. Ft. Number of Bedrooms H
53
APPLICATION IS FOR:
APPLICATION IS AN:
TYPE OF DWELLING:
(® all that apply)
Absorption Field
❑
Initial ❑
Single Family (SF) 0
(w/wo ADU)
Septic Tank
❑
Upgrade ❑ X
Duplex (D) ❑
Holding Tank
ElRenewal
ElMultiple
Dwellings ❑
Privy
❑
(SF and/or D)
Private Well
0
Water Storage
❑
THIS APPLICATION INCLUDES
A WAIVER REQUEST FOR:
Distance:
I certify that the above information is correct. I further certify that this is in accordance with
applicable Municipal Codes.
(Signature of property
f �
r or authorized agent)
Permit/Rush Fees: 2 Waiver Fees:
Date of Payment: 6 420.2 1 Date of Payment:
Receipt Number: 04/(o 2 1h Receipt Number:
Permit No. C�5e Z ) I [ 2 6 Waiver No.
GADevelopment Services\Building Safety\On Site Water and Wastewater\Forms\Client Forms\Permit Application.doc
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP211126, Rebecca Carroll, 05/05/21
Carroll, Rebecca M.
From: tan|iker <tan|iker@ao|zom>
Sent Wednesday, December 19.2O1811:43AK4
To: Carroll, Rebecca K4.
Subject: RE: Re: FW: Drinking Water Test Results
Follow UpFlag: Follow up
Flag Status: Flagged
Thanks Becca,
The septic for the house is not built since the house is not built. Before we proceed with anymore build we would
address the low flow well. Please let us know if the engineer does not answer your questions or if there is anything else
you need. We do not want to be in violation of anything or accrue fines. Thank you.
Tina
Sef",r via Ir"he Samsung Galaxy S7, an AT&T 4G LTE smartphone
Original message
From: "Carroll, Rebecca K4."<rebecca.cannU@anchonageak.gov>
Date: 12/19/1811:19AM(GK8T-O9:0D)
To: tan|ikpr«tanlike r@aoicnnn>
Subject: RE: Re: FW: Drinking Water Test Results
Thanks Tina,
I am still waiting for the engineer to get me a resubmittal to address my other review comments for OSPI 51290, but this
checks off one of them. Once | get those corrections, that will close out USP1S129O.
Asfor O5P151287 if the septic that was to serve the proposed house hasn't been installed, we would expire the
permit. In the future, if you proceed with building the house, the septic permit would need to be renewed and reviewed
against our new code. In addition, it appears that the well only produced 0.12 gallons per minutes, which is only enough
for aIbedroom residence. So that would need to be addressed in the future if a 2+ bedroom house was going to be
Let meknow if you have any question about any of this.
Becca Carroll
Onsite Water and Wastewater
Municipality of Anchorage
Municipality of Anchorage
On -Site Water and Wastewater Program • (907) 343-7904 Page l of 3
ON-SITE WASTEWATER INSPECTION REPORT
Permit Number: �S l�/S� z �d PID Number: (D,51 d %22 $
Dwelling: ,® Single Family (SF) ❑ Duplex (D) ❑ Multiple (SF and/or D) Project:/IFI�New ❑ Upgrade
Name:
! K
ABSORPTION FIELD
❑ Deep Trench Shallow Trench ❑ Bed ❑ Mound
Address
/3 G Z 4
❑ Other
Phone 4
Number of Bedr oms
Soil Rating
Total depth from original grade
Z ! ` Ql
3
/ 21, GPD/SF
S Ft.
LEGAL DESCRIPTION
Depth to pipe invert from original grade
S.5 Ft.
Gravel depth beneathpipe
Ft.
Subdivision Block Lot
Fill added above original grade n Ft
Gravel length y
,j a Ft.
✓-(
Township Range Section
� �
Gravel width
Ft.
Beds: Number of Lines
Distance between lines
— Ft.
SEPARATION DISTANCES
To
Septic
Absorption
Lift Station
Holding
Sewer.
Total absorption area
Number of trenches
Dist. between trenches
From
Tank
Field
Tank
Line
390 0 Fe
-- Ft.
Well_
Go
ZJr
TANK Septic ❑ S.T.E.P. []Holding ❑ Other
Manufacturer
r—
ICapacity
�� Q Gal.
/GG
Surface Water
GU
6G
Material
Number of compartments
Lot Line
LI'�
0
�
NA
..
Foundation
LIFT STATION
Manufacturer
Capacity
Q
Curtain Drain
r
_
Gal.
Remarks
Pump on level at
in.
Pump off level at
in.
High water alarm at
Pump make and model
Electrical Inspections performed by
Installer
Al
PIPE MATERIAL H ouse to tank Tank to
1) [� drainfield ��o3
Drainfield 3 CO/MT D
Inspector % f�,
BENCH MARK (Assumed elevation) �QQ ft
Inspection Z� / /�
dates: 6
Q
Location and description
�- /
3b 4m
A c
Fa,, a� C.
COMMUNITY DEVELOPMENT DEPARTMENT APPROVAL
Engineer's Stamp
Conditional Approval: apate
ra Y 0 O
Approved ��1 �� �
�
t~
� 4,� �i b,��:: s
w ��CC, Date ! � �� j �
.� }
,\ t_
��L�1ti�Ms`
Incnarfinn Rannrt Q_1_10 A—
75
d
0
L
i
d
U
4
P�
QJ -
Flat
Terrain
Well Over 100'1
Flat Alternat
Terrain
Flat
Terrain
Propos MT
/CO
TRENCH
Flat Flat
Terrain Proposed Terrain O
4 BdrM
Flat
Terrain
��V
Flat v
Terrain Well Over 100'
1250 Ga on
k
Well
0
i -R100
2 Bdrm
SVlo/p
1
Flat
Terrain
Flat New 1000 Gallon Septic Tank ST12 Flat
Terrain TH3J 3 DC❑1 Terrain
MT/CO C❑1
— — — — — — Tom— 50'
ROW o lternate EW
TRENCH TRENCH
A - M A
A B
ST1 64 12
ST2 66 18
DC❑1 67 20
C❑1 61 26
—
MT/CO 33 48
Well Radius 100
NORTHR/M
ENGINEERING
PO Box 770724
Eagle River, Alaska 99577
907.694.7028
1" = 50'
T15N R1W SECTI❑N 8
LOT 53 SHOP
WASTEWATER RECORD RECORD
SHOP ONLY Date:
12/27/1812 of 3
Septic
c-
u
c
oj
L
1-
06
y
U
-P
Ln
+1
:3
0
c
o
m
rn U
II Cj)
c
c In
0 0
:p n
0
> 0
ai N
In
-P
:31
1
0
CD
(4-
0
d-5
(YTL
0) d
>
0
u
E-1
y
In
c-0
(T
C5
OW
L,
Mr.
in
Ln
'4
N
CD
(4-
0
00
(YTL
E-1
In
ti
0
Lj
0
0
Ln
co
LnCll
F—I
>
'T4
�
0i
LLJ
LLJ
Ej,
>
ED
M I I I
-u
ry
n
7 -
Li
Lj
p -Q
U
(Y)
0-
06
LL- L L -
Qi
LLJ:
F CL
U')
>
Cl)
lq-
-:p
-E
CTN
(�j
U
0
-0
Li
in
Ln
'4
N
(4-
0
00
E-1
In
ti
Lj
Ln
co
LnCll
F—I
�
LLJ
LLJ
LLJ
ED
N
F ---i u
>
ED
M I I I
rl/ :
ry
n
7 -
Li
Lj
U
(Y)
H'
u
n
LLJ:
F CL
SOILS LOG — PERCOLATION TEST
Date Perf ormed: 11/1/16
Legal Description: T15N R1W Section 8 Lot 53
Organic
2
3
4 - SP Sand
5 - W/ Gravel
6
7
10
12
13
14
15
16
17
18
19
20
21 - I
Comments:
TR Location: See Attached Design
Groundwater? No
Depth
Water Depth
After Monitorino.None
Date: 12/1/16
#
Date
Gross Time
Net Time
Depth
Net Drop
1
11/1
0
7#
2
11/1
10
10 min.
MY
3,5"
3
11/1
12
--
7#
--
4
11/1
22
10 min,
10.5'y
3,50
5
11/1
25
--
7#
--
6
11/1
35
10 min,
MY
3,5'y
7
11/1
37
--
7#
--
8
11/1
47
10 min,
MY
3,5"
9
11/1
50
--
7#
--
10
11/1
60
10 min,
10.50
3.5"
Percolation Rate 3 min,/inch Perc Hole Diameter
Test Run Between 3' and 4'
6//
Per -Formed By NorthRim Eng, 1 2- CERTIFY THAT THIS TEST WAS
Per -Formed in Accordance with State/Municipal Guidelines in Effect
L/
ON THIS DATE, DATE: AINNOW I /
S
OF
NORTNRIaV1�;sm.
TESTHOLE LOG
TH3
ENGINEERING ....
PO Box 770724 .. . .....
Eagle Rlyer; Alaska 99.577
9OZ 694.7028
GEOTECHNICAL r°atil/1/16 fT .
3 of 3
Certified Drilling Log,
O DOC CO dba
BILL Sc COLE
��►ULLIVAN WATER WELLS
rtP.O. Box 670269, Chugiak, AK 99567 6$$-2759
OWNER OF LAND: Blaine Anliker
ADDRESS: PO BOX 670228 Chugiak, AK 99567
LEGAL DESCRIPTION T15N R1W SEC 8 LOT 53
DATE: 9-23-15
PERMIT NUMBER: OSP151290 DATE OF ISSUE: 5-28-15
TAX IDENTIFICATION NUMBER 05109228000
Is well located at approved permit location: ®Yes ❑No
Method of Drilling: ®air rotary ❑cable.tool
Depth of Well: 400'
Casing Type: Steel Wall thickness .250 inches
Diameter: 6 inches, depth 204. feet
Liner type
Static Water Level: 106.5 feet
Recovery Rate 7 ❑ gpm ® gph
Method of Testing Air
Well Intake Opening Type: ❑ open end ®open hole
❑ Screened Start feet Stopped
❑ Perforations Start feet Stopped
Grout Type: Bentonite Volume: 50 lbs
Depth: from 2 feet, to 42 feet
Well Disinfected Upon Completion: ®yes ❑ no
Method of Disinfection: Chlorine 50 PPM
Comments:
Bore Hole Data
Depth
From To
0 2
2 4
4 40
40 48
48 60
60 83
83 175
175 189
189 282
282 i 400
Casing Stickup
Overburden
Hardpan
Hardpan w/ Clay
Tight Silty Sand & Gravel
Gravel & Clay
Clay
Gravel & Clay
Sandstone
Shale
Drillers Name: Cole Sullivan
ATTENTION: It is the responsibility of the property owner to submit a copy of the well log to the proper authority.
Municipality of Anchorage: Department of Health & Human Services and/or Department of Environmental Conservation.
Matsu Borough: Department of Environmental Conservation.
t1/
DevelopmenT Services Department
Building Safety Division
On -Site VV&er di Wastewater Program
4700 Elmore Road z .0 k :N1 y
-^ P.O. Box 196650 "
e, AK 99507
Anchorage, s A E r Y
Mark Begich 9
Mayor www.muni.org/onsite
(907)x+343-7904 p
Fume �nsta��C�ft Log
Well Drilling Permit Number: SW Date of Issue:
Parcel )Identification Number: 051 69 Z -28
Legal Description
Property Owner ame & Address:
Pump Installation Date:%r
Pump Intake Depth Below Top of Well Casing: �bDfeet
Pump Manufacturer's Name: ( t�
Pump Model: $ 52c
Pump Size I hp
Pitless Adapter Burial Depth: i feet
Pitless Adapter Manufacturer's Dame:
Pitless Adapter Installer:
Well Disinfected Upon Completion? es ❑ No
Method of Disinfection: 140C '713
Comments:
+0.m ANCHORAGE WELL & PUMP SERV.
Pump Installer Flame: 330 EAST 76T" AVENUE
ANCHORAGE, AK 99518
PHONE: 907-243-0740
AWPS.COM
Attention: The pump installer shall provide a pump installation log to the DSD within 30 days of pump installation.
MUNICIPALITY OF ANCHORAGE
Community Development Department r Phone: 907-343-7904
On -Site Water & Wastewater Program Fax: 907-343-7997
Septic Svstem Owner -installer Agreement
A real estate property owner (Owner) may install their own septic system
The department may issue an approval for a homeowner to perform work on a conventional
(not AVWVTS) on-site wastewater disposal system to serve that individual's owner -occupied,
single-family or duplex home if the homeowner satisfies and agrees to the following
requirements.
The property owner and excavation equipment operator may perform work on no more than
one owner installed project in a 12 -month period.
As owner of (legal description) o�bp rM,n. �C`Fagree the
following items are true and accurate.
1. My experience installing septic systems is as follows.
2. The name of the excavation equipment operator is. &_k /` f S- g� !,
3. There will not be compensation for installation services rendered.
4. 1 will be actively involved with the septic system installation at all times.
5. The name of the inspecting engineer is 05C4
6. 1 agree to discuss the following items with the inspecting engineer:
a. Permit design criteria and specifications.
b. Inspection requirements set forth in AMC 15.65.150.
c. 2 -hour minimum advance notice given to the On-site Water & Wastewater
Program for all required municipal inspections.
7. 1 agree any changes I make to the items listed above will require a new approval before
performing work.
8. 1 agree to have the project -specific On-site Wastewater Disposal System Permit available
at the construction site for the duration of all related work.
Owner's printed name:. �lG(�nP, a /1;4�if
I
Owner's signature: .���/���sr-� Date: te'
Septic System Owner Installer Agreement_Feb2015.doc
Permit Number:
Tax Code Number:
Work Type:
On-Site Wastewater Disposal System Permit
OSP151290
05109228000
Septic
MUNICIPALITY OF ANCHORAGE
Development Services Department
On-Site Water & Wastewater Program
4700 Elmore Road, PO Box 196650
Anchorage, AK 99519-6650
Telephone: (907) 343-7904
Initial
Permit Effective Dates: August 28, 2015 to August 27, 2016
Design Engineer: NORTH RIM ENGINEERING
Subdivision: T15N RIWSEC 8
Site Legal Address: T15N R1W SEC 8 LT 53 G:1357
Owner/Address: ANLIKER BLAINE
PO BOX 670028 CHUGIAK AK 995670028
Site Mailing Address:
Lot Size in Sq Ft: 108900
Total Bedrooms: 3
This permit is for the construction of:
Y Disposal Field Y SepticTank N Holding Tank N Privy N Private Well N Water Storage
All construction must be in accordance with: 1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater
Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80).
3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services
Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either:
A. Open and Close on the same day.
B. Covered, sealed, and heated to prevent freezing.
Special Provisions: The entire subsurface disposal field and alternate of the shop system is not
within a 30 foot radius of a percolation test. The Engineer needs to do two additional percolation
test prior to the construction of the septic field. Please submit stamped and signed results with
the As-built Inspection Report. If the results require a design change, construction of the system
will stop pending On-Site review and approval. AMC 15.65.060.B.3
Received By:
Issued By:
Date:
Date:
MUNICIPALITY OF ANCHORAGE
Community Development Department
Development Services Division
On-Site Water & Wastewater Program
Phone: 907-343-7904
Fax: 907-343-7997
ON-SITE SEWER/WELL PERMIT APPLICATION
Parcel I.D. (~) .~'/
Property owner(s)
Mailing address
Site address
Day phone
Legal description (Sub'd., Block & Lot)
Legal description (Township, Range & Section)
Lot Size .Z/G~..~'~O Sq. Ft. Number of Bedrooms
APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING:
([~ all that apply)
AbsorptiOnseptic TankField ~[~ Upgradelnitial 'I~ Single(w/woFamilYADu)(SF)
~ Duplex (D)
Holding Tank U Renewal []
Multiple Dwellings
Privy [] (SF and/or D)
Pdvate Well []
Water Storage []
THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR:
Distance:
I certify that the above information is correct. I further certify that this is in accordance with
applicable Municipal Codes.
(Signature of property owner or authorized agent)
Permit/Rush Fees: ~(,,~ -
Date of Payment: ~'lt~. I[¢ ('~
Receipt Number: O~O~ ,~
PermitNo. ~SJCJ.~ j'~b
Waiver Fees:
Date of Payment:
Receipt Number:
Waiver No.
Permit App_9-1-12.doc
Permit Number:
Tax Code Number:
Work Type:
On-Site Water & Wastewater System Permit
OSP151287
05109228000
WellSeptic
MUNICIPALITY OF ANCHORAGE
Development Services Department
On-Site Water & Wastewater Program
4700 Elmore Road, PO Box 196650
Anchorage, AK 99519-6650
Telephone: (907) 343-7904
Initial
Permit Effective Dates: August28,2015 to August27,2016
Design Engineer: NORTH RIM ENGINEERING
Subdivision: T15N R1W SEC 8
Site Legal Address: T15N RIW SEC 8 LT 53 G:1357
Owner/Address: ANLIKER BLAINE
PO BOX 670028 CH UGIAK AK 995670028
Site Mailing Address:
Lot Size in Sq Ft: 108900
Total Bedrooms: 7
This permit is for the construction of:
Y Disposal Field Y Septic Tank N Holding Tank N Privy Y Private Well N Water Storage
All construction must be in accordance with:' 1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater
Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80).
3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services
Department at feast 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either:
A. Open and Close on the same day.
B. Covered, sealed, and heated to prevent freezing.
Received By; ^~"-/~ ~
/
/IUNICIPALITY OF ANCHORAGE
Community Development Department
Development Services Division
On-Site Water & Wastewater Program
Phone: 907-343-7904
Fax: 907-343-7997
ON-SITE SEWER/WELL PERMIT APPLICATION
Parcel I.D. (~1.~'! '- 0¢~.' ZO~
Property owner(s) ,~/~ ,~ ~ ~/,
Mailing address ¢0 ~ ~ZOO~
Site address Of~ ~?
Legal description (Sub'd., Block & Lot) ' ~
Legal description (Township, Range & Section)
Lot Size
Day phone
Number of' Bedrooms
APPLICATION IS FOR: APPLICATION IS AN:
(l~ all that apply)
Absorption Field ~ Initial
Septic Tank Upgrade []
Holding Tank Renewal []
Privy []
Private Well
Water Storage
TYPE OF DWELLING:
Single Fa~L.~) ,/~
Duplex (D). []
Multiple Dwellings []
(SF and/or D)
THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR:
Distance:
I certify that the above information is correct. I further certify that this is in accordance with
applicable Municipal Codes.
p perty owner o/~authorized agent)
Permit/Rush Fees:
Date of Payment:
Receipt Number:
PermitNo. ~l~
Waiver Fees:
Date of Payment:
Receipt Number:
Waiver No.
Permit App_9-1-12,doc
ENGINEERING
MEMO
Steve Eng, PE, PH
P.O. Box 770724, Eagle River AK 99577
(907) 694-7028 tel
SteveEngPE@gmail.com
Date: 8/17/15
To: MOA On-Site Services
Subject: TISN R1W Section 8 Lot53
New Septic Systems
Number of Pages:
A lot is being developed. This is a large lot with 50' ROW's. A 4-bedroom house and shop will
each have a separate septic system. The shop will be sized at 3-bedrooms.
A water well is also being sited. No conflicts exist with the neighboring lots. A number of soil
tests in the area reveal sandy soil with gravel and no groundwater. The design calls for two 5'-
wide trenches. Two new soil tests were completed to verify the soil. The entire area is on wells
and septic systems. The terrain slope is flat.
Please review the wastewater system designs and well site. I have included design plans & specs,
design guidelines, & soil tests. If there is need for additional information or clarification please
give me a call.
Thanks-Ste~
ENGINEERING
% ~/1~;~ T15N R1W Section 8 Lot 53
SPECIFICATI~~~N GUIDELINES
Wastewater System Sizing: T~s is a new 4-be&oom, single t~ily home. 2 sep[tic
systems ~i1 be b~lt; for house ~d shop. Most neighbor lots ~e developed. These lots
~e large ~d ~e se~ed by private water wells. No adverse impacts ~e expected from
development. No conflicts to the other lots will t&e place by this septic system
construc6on. The easements ~e located on the &awing and are not encroached upon. Soil
tests revealed sandy soil wi~ low silt. 2 soil tests were identical. ~ application rate ot
1.2 GPD/FT~ with 0.5 re&ction factor for utilizing a 5' wi& ~ench. House Trench
Length = 500 FT~/5'x .5 re&ction factor = 50'; 1 line ~ 50'. Shop Trench Length: 375
FTa/5'x .5 re&etlon factor = 3g'; 1 line ~ 38'. No bedrock was encountered or
groundwater was enco~tered. 1250 GMlon t~ for house, 1000 gallon t~ for shop.
Specification Requirements: All components ~d work must comply with the
Municipality ot ~chorage Specifications (AMC) & State otAlaska DriVing Water
Regulations and Wastewater Reg~ations.
Two comp~ment, 1250 gallon septic t~k for house, 1000 gallon t~ tot shop.
Wateaight couplings on inlet & outlet. New Double Cleanouts.
5' minim~ between ~e ~ and trench. 10' to propeay lines.
· 3' of cover or insulation is required tot trench; 2" Minim~ tl~c~ess tot insulation
c~ substitute for 1' cover.
· T~ & solid pipe must be set on well compacted, stable soil.
· 4 inch diameter cleanouts with ai~ight caps are req~red 1' to 4' from foundation
wall, prior to any 90 degree bend in 4 inch line, in each trak comp~ent, ~d two
adjacent opposing cl¢~outs bergen ~e t~k ~d ~e abso~tion field, not more ~an
10' from the ~ positioned to provide cle~out access tow~ds the ~ and towards
· e absorption field.
All cle~outs must extend to at least gro~d level.
In solid pipe r~s, ASTM D-3034 may be used in lieu of cast iron.
Trench to be level, minimum of 4' to groundwater, 6' to bedrock kom &~n-rock.
Drain ro& to be ~ inch to 2 ~ inch screened. Drain rock to be dis~ibuted ~ito~ly
t~ou~out the trench.
· Perforated pipe to be ins~lled level wi~ perforations down.
Silt ba~mr (filter fabric) to ~e installed above ~e &ain rock.
Sme~ed trench sides must be r&ed or sc~ified before &~n rock placement.
· Backfill over drain rock must not be less th~ 36".
The finish grade must be molded to promote &~ge away kom ~ench.
Insulation must be placed over ~y pipe installed ~der driveways or p~king ~eas.
Approved pipe materials inclu& cast iron, PVC ASTM D3034, PVC ASTM F789,
ABS ASTM D2661,
· Sewer Service Line is minim~ 2% slope.
Septic T& to be p~ped eve~ two yeaxs or when required.
· Insulation bo~d to be exuded direct burial polystyrene (Dow Styrofo~ HI/equal)
V/eL[ Over 100~1
FLat
Terrain
Alternate
TRENCH
Flat
o
Flat
Terrain
FLat
Terrain
House
4 Bdrm
NE~/ Terrain
TRENCH MT/CO
FLat
Terrain
TH
Flat
Terrain V/ell
1,1,01
Proposed V/ell
Flatc
Terrain
Over lO0'
Flat
Terrain
Terrain
50'
ROY/
Shop
Flat a~
~)err
TH _ /---/
/ / Terra
/ .~__~Alt;erno, t;e / NEW
New 1000 Gallon/ TRENCH '-----"
TRENCH
Septic Tcmk w/I)CO's Flat
Terrain
FLat;
Terrain
DESIGN NOTES:
1. Total Depth of Both Trenches is 7,5'. ~ ~ ]
Flat Terrain.
2. Sewer Service Line minimum 2% slope./~ I %
5. Private Water Wells. / ~. R~,~~,o0 I '
Sep't:ic
NOR THRIM
907.894. 7028
T15N Ri~/ SECTIDN 8
LOT 53
~/ASTEV/ATER DESIGN
2 NE~/ SEPTICS
1'=50'
PLAN
LAYOUT
8/88/15 ? 3
u
0
fl.
Eli
0
c
OJ
c
>
0
0 CT
Ohl
h
~- 0
_C
U
0
0
00~
= ~-~
c-
0
n
r~
0
~c
c
>
0
0 O-
Obi
-{2
C
Q-
0
+~
C
c
0
IX THRIM?
ENGINEERING
SOILS LOG - PERCOLATION TEST
Date Pen¢or'med: 8/~0/15
Pep¢opmed Fop: Blaine
Legal Description: T15N R1W Section 8 Lot 53
DEPTH
(FEET)
15 -
17
~9
80 -
Organic
T,H, Location~ See Attcched Design
SP Sand
w/ Graver
Groundwater? No
Depth --
Water Depth
AFter Monitoring,None Date: 8/17/15
Comments: Preqoakpd,
PerFormed By--g,
PerFormed in
ON THIS DATE.
# Dat;e Gross Time Ne't Time Dep'th Net; Drop
1 8/17 0 -- 7. --
2 8/17 10 10 rain, 10,5" 3,5"
3 8/17 12 -- 7, --
4 8/17 22 10 mir, 10,5~ 3,5'
5 8/17 85 -- 7,, --
6 8/17 35 10 mir, 10.5' 3,5"
7 8/17 37 -- 7,, __
8 8/17 47 10 min, 10.5" 3,5'
9 8/17 50 -- 7' --
10 8/17 60 10 min, 10.5' 3,5'
PercoLation Rote 3 min,/inch Perc Hote Diameter 6"
Test Run Between 3' and 4'
I ~ CERTIFY THAT THIS TEST
Accordance wiSh&t[ S~o~e/Municipc[ Guidetines in
TESTHBLE LBG
GEOTECHNICAL
TH1
8/i7/15 Ii_Pr a
THRIM
INEERING
Date PerFormed: 8710/15
PerFormed For: B[cine
Legal Descrip$ion: T15N RlW Section 8 Lot 53
2 -
3 -
4 -
5 -
6 -
7 -
8 -
9 -
10
11 -
13 -
14 -
16 -
17 -
18 -
20 -
DEPTH
(FEET)
Orgcnic
SP Send
w/ Gpcve[
T,H, Locction~ See Attcched Design
Groundwcter? No
Depth --
Water Depth
AFter Monitoring,None Dote: 8/17/15
~ Dote Gross Time Net Time Depth Net Drop
1 8/17 0 -- 7. --
B 8/17 10 10 min, 10.5" 3,5"
3 8/17 12 -- 7, --
4 8/17 22 10 rain, 10,5' 3.5'
5 8/17 25 -- 7, --
6 8/17 35 lO min, 10,5" 3,5'
7 8/17 37 -- 7' --
8 8/17 47 10 rain, 10,5' 3,5'
9 8/17 50 -- 7,, __
10 8/17 60 10 rain, 10,5' 3,5'
Comments: PremockPd,
Performed B y ~lDJ:2~:~l~n g, I CERTIFY
PerFormed in Accordance wit.h,A~ Stcte/Municipd
ON THIS DATE, DATE:
................
~OR THRIM
* ~9~ ". *
~.,,?.~ TESTHBLE LBG
EN~INggRIN~
'~'~' ~ ~ '~/~ ~ G E B T E C H N I C A L
PercoLation Rote 3 min,/inch Perc HoLe Diometer 6'
Test Run Between 3~ end 4~
Measurpd ±n npnrp~± 1/16, th lnrh.
THAT THIS TEST WAS
GuideUnes in EFFect
TH2
8/17/17_