On-Site Water and Wastewater Program
(907) 343-7904
CERTIFICATE OF ON-SITE SYSTEMS A~
Parcel I.D. 008-071-35
Expiration Date:
1. GENERAL INFORMATION
Complete legal description T13N R3W SEC 33 LOT 43 W2
Location (site address) 2608 E 48TM AVENUE, ANCHORAGE, AK 99507
Current Property owner(s)
Mailing address
Real Estate Agent
GLORIA PARRET Day phone
2608 E 48TM AVENUE, ANCHORAGE, AK 99507
Day phone
TYPE OF DWELLING: [] Single Family (w/wo ADU)
[] Duplex
[] Multiple Dwellings (Single Family and/or Duplex)
3. NUMBER OF BEDROOMS: 5
4. TYPE OF WATER SUPPLY:
Individual Well
Individual Water Storage
Community Class Well
Public Water System
TYPE OF WASTEWATER DISPOSAL:
WaiverNariance request for:
COSA to be reteased to the othen,v],~l~cl by the engineer.
Individual []
Holding Tank []
Community []
Public Sewer []
Distance:
Date:
COSA Fee $
Date of Payment
Receipt Number
COSA Cf
qlttl/6
Waiver Fee $
Date of Payment
Receipt Number
Waiver #
STATEMENT OF INSPECTION BY ENGINEER
As certified ffixed hereto and as of the validation date shown below, I verify that my investigation,
based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines for this application,
shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate
for the number of bedrooms and type of structure indicated herein. I further vedfy that based on the information
obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water
supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes,
ordinances, and regulations in effect at the time of installation.
Name of Firm ARCTERRA CONSULTING, INC.
Phone 868-3791
Address 20441 PTARMIGAN BLVD., EAGLE RIVER, AK 99577
Engineer's Printed Name KENNETH M. DUFFUS
Date 8/25/15
Engineer's Comments: This investigation was completed in compliance with ADEC and MOA regulations, The assessment of the condition
of the well and septic applies only to the conditions as of the day tested, The flow and absorption rates may change due to subsurface
conditions that may not be observed from the surface, changes inland use, local soil characteristics, groundwater levels that may fluctuate
during the year and the water usage of the family being served by the system. The operational life of all well and septic systems are
subject to these vadous and dynamic characteristics and ara outside the control of the
evaluator of the well and septic system, Therefore,
ArcTerra can not give any estimate of how long a
system will function satisfactory for currant or future
occupants or can ArcTerra guarantee that no unseen
encroachments, deficiencies or discrepancies exist.
DSD SIGNATURE
~'" System #1 Approved for
System #2 Approved for __
Disapproved.
..~ bedrooms.
bedrooms.
Conditional approval for
bedrooms, with the following stipulations:
ON-SITE
WATER AND rn
'~.'~ PROGRAM
Original CeKiflcate Date: ff W ~ -/~
issues Certificates of On-Site Systems Approval (COSA) based only
upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality
of Anchorage is not responsible for errors or omissions in the professional engineer's work.
ATTACHMENTS:
COSA Checklist
Septic System Advisory
Well Flow Advisory
X
Nitrate Advisory
Arsenic Advisory
Other
If more than t s[eptic syS~m is on the lot:
COSA Checklist # of
Structure served by this system _
Certificate of On-Site Systems Approval Checklist
Legal Description:
A. WELL DATA
Well type PR~I'
Date completed CIRCA 1965
Total depth Unknown ff.
T13N R3W SEC 33 LOT 43 W2
IfA, B, or C provide PWSID #__
Sanitary seal (Y/N) Y
Cased to 40+ ff.
Pamel ID: 008-071.35
FROM WELL LOG
Date of test ..
Static water level -- ft.
Well production -- g.p.m,
Well Log (Y/N) N
Wires properly protected (Y/N) _Y
Casing height (above ground) 18
AT INSPECTION
8/1412015
84 ff.
3.9 g.p.m.
in.
WATER SAMPLE RESULTS:
Coliform t~4~ colonies/lO0 mL Nitrate /I/'/~ _mg/L
Arsenic: ]~, ~ ug/L Date of sample: 8114i15
Collected by: ARCTERRA
B. SEPTIC/HOLDING TANK DATA - PUBLIC SEWER
Tank Type/Material
Tank size __ gal.
Foundation cleanout (Y/N)
Date of pumping
Number of Compartments
Depression over tank (Y/N)
Pumper
Date installed
Cleanouts (Y/N)
High water alarm (Y/N)
C. ABSORPTION FIELD DATA
Date installed
Length
Total depth ft.
Date of adequacy test
Soil rating (g.p.d./ft2 or ~/bdrm) _
ff. Width
Eft. absorption area _ft2 Monitoring tube
Results (Pass/Fait)
Fluid depth in absorption field before test __ in.
Elapsed Time: min. Final fluid depth
Any rejuvenation treatment (past 12 mo.) (Y/N & type)
System type
Gravel below pipe
Depression over field
Water added gal.
in. Absorption rate >=
If yes, give date
For bedrooms
New depth in.
g;p.d,
D. LIFT STATION
Date installed
"Pump on" level at __ in.
Datum
Size in gallons
"Pump orr' level at __ in.
Cycles tested
Manhole/Access (Y/N)
High water alarm level at
Meets alarm & circuit requirements?
in.
E. SEPARATION DISTANCES
WELL ON LOT TO:
Septic tank/lift station on lot NA
Absorption field on lot NA
Public sewer main 75'+
Sewer/septic service line 25'+
Animal containment areas
On adjacent lots NA
On adjacent lots NA
Public sewer manhole/cleanout 100'+
Holding tank NA
Manure/animal excrete storage areas IQO'+
SEPTIC/HOLDING TANK ON LOT TO: PUBLIC SEWER
Building foundation
Water main
Wells on adjacent lots
Property line __
Water service line
ABSORPTION FIELDON LOTTO: PUBLIC SEWER
Property line
Water Service line
Curtain drain
Building foundation
Sur[ace water
Wells on adjacent lots
Absorption field
Surface water
Water main
Driveway, parking/vehicle storage
F. COMMENTS
G. ENGINEER'S CERTIFICATION
I certify that I have determined through field inspections and review of
Municipal records that the above systems are in conformance with MOA
COSA guidelines in effect on this date.
Engineer's Printed Name KENNETH M. DUFFUS
Date 08/25/'15
COSA canary sheet..2-6-15.doc
EAST 48th AVE~E
Roberl E.~:~e:~s, Jr..~::Assoc.
Municipality of Anchorage
Community Development Department
Development Services Division
On-Site Water and Wastewatcr Program
4700 Elmore Street
P.O. Box 196650 Anchorage, AK 99519-6650
w~vw.muni.org/onsit¢
(907) 343-7904
Arsenic Advisory
Certificate of On-Site Systems Approval # 151502
A Certificate of On-Site Systems Approval inspection and test of potable
water was recently conducted on the well water supply on Block , Lot
43 W2 of T13N R3W Section 33 Subdivision. This inspection revealed an
arsenic concentration of 14.7 micrograms per liter (ug/L) for the property's
well water sample. The Environmental Protection Agency (EPA) has
established a maximum contaminant level (MCL) of 10.0 ug/L for public
drinking water systems. While private wells are not subject to this
regulation, EPA standards are based on existing health information and can
therefore be used to gauge the relative quality of water from private wells.
Information on arsenic is available from the On-Site Water and Wastewater
Program website (www.muni.org/onsite) or at 343-7904.
This advisory must be attached to all copies of the subject Certificate of On-
Site Systems Approval.