Loading...
HomeMy WebLinkAboutRABBIT CREEK BLK 1 LT 2Rabbit Cre k Block I Lot 2 #017-063-41 On-Site Water & Wastewater System Permit MUNICIPALITY OF ANCHORAGE Development Services Department On-Site Water & Wastewater Program 4700 Elmore Road, PO Box 196650 Anchorage, AK 99519-6650 Telephone: (907) 343-7904 Permit Number: OSP151340 Tax Code Number: 01706341000 Work Type: WellSeptic Initial Permit Effective Dates: October 12, 2015 Design Engineer: ManyokySandor Subdivision: RABBIT CREEK Site Legal Address: RABBIT CREEK BLK 1 LT 2 G:2939 Owner/Address: DUNCAN CHARLES E PO BOX 212706 ANCHORAGE AK 995212706 to October 11, 2016 Site Mailing Address: 6841 OUR OWN LN, Anchorage Lot Size in Sq Ft: 45989 Total Bedrooms: 3 This permit is for the construction of: Y Disposal Field Y SepticTank N Holding Tank N Privy Y Private Well N Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80). 3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either: A. Open and Close on the same day. B. Covered, sealed, and heated to prevent freezing: Received By: Issued By: Municipality of Anchorage P.O. Box 196650 · 4700 Elmore Road Anchoraqe, Alaska 99519-6650 · (907) 343-7904 · Fax ~'9071 343-7997 httD:l/www.mu ni.omlOnsite Development Services Division On.Site Water and WasteWater Pro, ram **** VARIANCE/WAIVER REVIEW **** WaiverS: OSVt5t137 COSA#: Permit: OSPt5t340 PID#: 0t7-063-4t Legal Description: Rabbit Creek. Block 1. Lot 2 Engineer: Sander Manyoky, P.E. Applicant: Charles Duncan. Your request for a waiver of the required 50 feet horizontal separation from the absorption field to the 25% or greater slope has been approved. The approved separation distance is 32.0 feet. This waiver approval applies to the proposed absorption field only. Any future upgrade to the On-site wastewater dispOsal system will require all separation distances be met or another approval from this department. [] The affected adjacem property owner(s) have been given a 7 day notice regarding this waiver. [] Notarized letter(s) of non-objection have been received from the owner(s) of the affected adjacent property. [] Adjacent properties are not affected by this waiver, Waiver is Granted: X Waiver is not Date: ~ t~//r Approved by:/ t / · .... 'ame of Reviewer ............. ............... .............(~..~.~.o..f.......................... MUNICIPALITY OF ANCHORAGE Community Development Department ~i~L~ p~ Development Services Division / On-Site Water & Wastewater Program /~ i,~ ON-SITE SEWER/WELL PERMIT APPLICATIOr~ Parcel I.D. 017-063-41-000 Property owner(s) CHARLES E DUNCAN Day phone 344-4855 Mailing address 66841 OUR OWN LANE ANCHORAGE,AK 99507 OCT 0 x //:lS. Site address SAME Legal description (Sub'd., Block & Lot) BLK 1 LOT 2 RABBIT CREEK SUBD. Legal description (Township, Range & Section) Lot Size 45,989 _Sq. Ft. Number of Bedrooms 3 APPLICATION IS FOR: ([~ all that apply) Absorption Field [] Septic Tank [] Holding Tank [] Privy [] Private Well [] Water Storage [] APPLICATION IS AN: Initial [] Upgrade [] Renewal [] THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR: DRAINFIELD TO SLOPE GREATER THAN 25% TYPE OF DWELLING: Single Family (SF) [] (w/wo ADU) Duplex (D) [] Multiple Dwellings [] (SF and/or D) I certify that the above information is correct, further certify that this is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit/Rush Fees: Date of Payment: Receipt Number: Permit No. Waiver Fees: Date of Payment: Receipt Number: Waiver No. 03VI5 ! h3--/- Permit App_2- '.. :Z..:c; HAAS & A~SOC/ATES, CIVIL ENGINEERING CONSULTANTS * MATERIALS TESTING o ENVIRONMENTAL SERVICES September 30, 2015 MOA Building Safety On-Site Services 4700 Elmore Road Anchorage, Alaska 99519 Reference: Lot 2, Block 1; Rabbit Creek Subdivision on site well and septic system pemtit. Dear Plan Review Engineer: Please find enclosed our design documents for an on-site well and septic system serving the proposed 3 bedroom private residence at Rabbit Creek subdivision. We are proposing to install a private well, a 1,500 gallon septic tank with a lift station m~d a 25'long deep trench with 7.5' of gravel below the distribution pipe. On August 9, 2015, we excavated a test hole to determine ground water condition and soil absorption in the subsurface formation. (TH1). The attached soils log shows groundwater monitoring and percolation test results (4 minutes/1 inch). The topography of this lot is as follows: Steep slopes greater than 25% to the south as shown in our topographic map, and; About 5%-8% cross slopes to the east at the lower level. We are requesting a distance waiver between the proposed deep ~xench and the existing ground slope to the south, which is greater than 25%. The required 50' from the proposed trench cmmot be obtained due to the steep slopes and the location of the north property line. Based on the MOA guidelines regarding distance waivers, the maximum attainable distance to a slope steeper than 25% is only 32'. We therefore request a distance waiver for this on-site septic system. The on-site water and septic system will have no adverse effect on the surrounding wells, septic systems, or surface waters if the system is constructed as per the approved design documents. Drainage patterns will be restored to pre-construction conditions. If you have any questions, please contact me at 947-3499. S inc erely, ~ ;~/i~ '~ Sandor Manyoky, P E Civil Engineer 3900 E. 112'" Avenue*Anchorage, Alaska 99516,TEL (907)349-8799.FAX (907)349-8791.haas@gci.net J / / /( O~ O~ n~j 0 0 0 0 0 0 0 0 + 0 + 0 0 8 0 HAAS & ASSOCIATES, INC. Civil Engineering Consultants 3900 E. 112th Avenue ANCHORAGE, ALASKA 99516 haas@gci.net TEL: (907) 349-8799 FAX: (907) 349-8791 SHEETNO CALCULATED BY ~ CHECKED BY. SC^LE /b'7--> OF DATE Performed For: Legal Description: TH -£ 1 2- 3- 4- 5- 6- 7- 8- 9- 10- 11- 12- 13- 14- 15- 16- 17- 18- 19- 20- COMMENTS Municipality of Anchorage Development Services Department Building Safety Division On-Site Water and Wastewater Program 4700 Elmore Road P.O. Box 196650 Anchorage, AK 99507 www. ci.anchoraqe.ak.us (907) 343-7904 Soils Log - Percolation Test Slope / / / / ENCOUNTERED? IF YES, ATWHAT DEPTH? Depth to Water After Monitoring? o P Date: Reading Date Gross Time Net Time Depth to Water Net Drop 8~q~-~~ Z; /~-~ /. I~-.E ~:~¢ 30 ¢,,9/ 7,7~/'' PERCOLATION RATE 4~ (minutes/inch) PERC HOLE DIAMETER TEST RUN BETWEEN '7.~-- FT AND ~J4'FT PERFORMED BY: .~'¢/c:¢~i" hC-cv'I,~::~JL~' I ~C~/'OY' ¢'~d?v[~"~-CERTIFYTHATTHISTESTWAS -- CT ON THIS DATE DATE "~"~ ~ /-~ PERFORMED IN ACCORDANCE WITH ALL STATE AN~ MUNICIPAL GUIDELINES IN EFFE . : ~ '