HomeMy WebLinkAboutMINDYER MANORS BLK 1 LT 6Mindye Manors Block Lot 6 #020-091-67 Permit Number: Tax Code Number: Work Type: On-Site Wastewater Disposal System Permit 0SP151349 02009167000 Septic MUNICIPALITY OF ANCHORAGE Development Services Department On-Site Water & Wastewater Program 4700 Elmore Road, PO Box 196650 Anchorage, AK 99519-6650 Telephone: (907) 343-7904 Initial Permit Effective Dates: October 19, 2015 to October 18, 2016 Design Engineer: ANDERSON CONSTRUCTION & ENGINEERING Subdivision: MINDYER MANORS Site Legal Address: MINDYER MANORS BLK 1 LT 6 G:3336 Owner/Address: LAMBE STEVEN SCOTT & KELLI ELIZABETH 16744 VIRGO DRIVE ANCHORAGE AK 995165345 Site Mailing Address: 4831 Virgo AVE, Anchorage Lot Size in Sq Ft: 55105 Total Bedrooms: 5 Department This permit is for the construction of: Y Disposal Field N SepticTank N Holding Tank N Privy Y Private Well N Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80). 3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either: A. Open and Close on the same day. B. Covered, sealed, and heated to prevent freezing. MUNICIPALITY OF ANCHORAGE . ~,,~mm~ni~ ,Iopment Department ~'/1~,~ Phone: 907-343-7904 ~DR~ntN~ l~'ices Division ~ Fax: 907-343-7997 On-Site Water ~astewater Program ' OCT ]~ ~015 ~' 15''0~ X / ON-~ITESEWE~WELLPERMITAPPUCATION ,, RUSH! J Propedyowner(s) ~L~v~ L u~ h~/ Dayphone Mailing address ~ ~ L~, Site address Legal description (Sub'd., Block & Lot) f'~',~',~"~.~-¢ Legal description (Township, Range & Section) LotSize ~'~'~'0 ~ .Sq. Ft. Number of Bedrooms APPLICATION IS FOR: ([~ all that apply) Absorption Field [] Septic Tank [~ Holding Tank [] Privy [] Private Well '~ Water Storage [] APPLICATION IS AN: Initial Upgrade Renewal TYPE OF DWELLING: Single Family (SF) [] (w/wo ADU) Duplex (D) [] Multiple Dwellings [] (SF and/or D) THIS APPLICATION INCLUDES A VARIANCE I WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. (Signature of property owner or authorized ageo~t) t ,'z..¢'*'[, ~ Permit/Rush Fees: ~=JO~ ¢"~'/'~' FC(tu Waiver Fees: Date of Payment: //2//~'/~'~;- Date of Payment: Receipt Number: ,~(-[~--~)0/-) Receipt Number: Permit No. O~'~ l~O~ Waiver No. Permit App_~- .. Michael N. Anderson, P.E. Ci¥il/Stmctural Engineehng & Construction 4661 Natrona Ave Anchorage, Alaska 99516 Phone 727-8864 Fax 345-1391 Oct. 15, 2015 Municipality of Anchorage Department of Health and Human Services P.O. Box 196650 Anchorage, Alaska 99519-6650 Re: Mindyer Manors S/D Blk 1, Lot 6 To Whom it may concerto This is a request for a new septic and well permit on the above referenced lot. A new test hole was excavated and found silty gravel GM with no water. The perc rate was 2 minutes with no water observed during the excavation or after the 7 day monitoring period. A deep trench system has been desired with an application rate of 1.2 gallon/sf/day. The slope is semi-flat with a 5 to 10 percent slope rmming from the east to west. This new system will not impact the surrounding properties or limit their future development. If you have any question please call me at 345-3377 Sincerely ~ ~ Michael N. Anderson, P.E. DESIGN CRITERIA: 5 BDRM X 150 = 750 GPD SOILS = 750/1.2 = 625 GPD 625 GA/12 = 52' (1) TRENCH 8.0' DEEP 6.0' EFFECTIVE 2.0' WIDE 52' LONG ~.~MOUND OVER /--GRADE -2'°~'~3 p\ /~---~.L~.~p~^BRIC -S R R°cK MINDYER ~ANOR RLK 2. LOT 1 MINDYER UANOR BLK 1, LOT 5 PROPOSED DRAINAGE 10' T&E WOOD RIDGE BLK 2, LOT 2 LINE Septic Design Prepored for RAY HICKEL MINDYER MANORS, BLK 1, LOT6 Anchorage, Alaska Michael N. Anderson, P.E. 4601 NATRONA AVE ANCHORAGE, ALASKA 99516 (907) 345-3377 / F,'MX: (907) 345-1391 DATE: 10/5/2015 DRAWN: D JR SCALE: 1"=100' 5 BEDROOM HOUSE / ~PROPOSED WELL / loo' RADIUS "~ SEPTIC ~, ".. W PROPERS' LINE DRK~'WAY ~~ 1500 GALLON . .." ~--PROPOSED WELL ./" '~ I00' RADIUS S1EE~L TANK ~ /" /"n r ~'6~.. \ PROPOSED QY BEDROOM HOBSE .. ,, ,, t'ho pL. ,, r//-- PROPERIY UNE ..--" ' ~ / "-. MINDYERMANORS, BLK1,LOT6 ~/ 49TM ~ Anchorage, Alaska ~,....,~ .......... .~......:..,.'. ......... ~.....~. ~.....~...~..~...*_ .'. ........................... ~:s MICHAEL N. ANDERSON.::~ Michael N. Anderson, P.E. DATE: I0/5,20~5 ~,?/~.... No. CE 9469 ~0~ .^~.o.^^v~ D~AW.: ~ '0:~?,.....,.,~,,/~-.:..'~:;,,..~ ,,.:.'.~ ~-- ANCHORAGE, ALASKA 99516 1"=~1~' "~? ~ ' ........ -'~"' (907) :145-3377 ! FAX: (907) 345-1301 SCALE:... ~25>C~:3~_~,'* Municipality of Anchorage I Development Se~ices Depa~ment Building Safety Division ~n-SJte Water and Wastewater Prog ram P,O. Box 196650 Anchorage, AK 99507 Soils Log - Percolation Test PefiormedFor: ~ /A'~~ ( DatePeflormed: Le~ D~o~iption: I~ ~ ~ ~ ~ ~ /~ ~ ~¢ ¢ ~To~nshi,, Rang~, S~tion: 3- 4- 5- L' I~0 4'E' ' 6- 8- 9- 10- 11- 12- 13- 14- 15- 16- 17- 19- 20- COMMENTS WAS GROUND WATER ENCOUNTERED? ~ O S IF YES, AT WHAT DEPTH? L O Depth to Water After p Monitoring? ~ E Reading Date Gross Time Net Time Depth to Water Net Drop PERCOLATION RATE ~ (minutes/inch) PERC HOLE DIAMETER ~.~ TESTRU. BE~VWEN ~F~ AND PERFORMED BY: 'J'"~ J '~J~"'~ J CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: