HomeMy WebLinkAboutSAND LAKE #2 BLK 5 LT 13Sand Lczke #2
Block 5
Lot 13
#011-134-24
(7�JI ffi:�)j''rj Fl�i-r;�r i i1
Municipality of Anchorage L uIJuU a Ii
IL
Community Development Department 3
APR 2 5 20
On -Site Water & Wastewater Program
4700 Elmore St. • P.O. Box 196650 Anchorage, AK 99519-6650 • http://www.muni.org/onsite • (907)343-7904
ON-SITE WASTEWATER INSPECTION REPORT
Permit Number: OSP151351 PID Number. 011-134-24 0 New ❑ Upgrade
Name:
WILCO CONTRACTORS
ABSORPTION FIELD
■ Deep Trench ❑ Shallow Trench ❑ Bed ❑ Mound
Address:
16701 RANSOM RIDGE ROAD, ANCHORAGE, AK 99516
❑ Other
Soil Rafing:
Total Depth from original grade:
Phone: No. of Bedrooms:
242-5443 4 (DUPLEX)
*4.0 GPD/Sq. FI.
10 (MAX-) FL
LEGAL DESCRIPTION
Depth to pipe invert from original grade:
SEE DWG.
Gravel depth beneath pipe:
7
Ft
Ft
Subdivision: Block: Lot:
Fill added above original grade:
Gravel length:
SAND LAKE #2 5 13
SEE DWG. Ft.
30 Ft
Owns Ip: anger Section:
-
Gravel width:
Beds Number of lines:
Distance between lines:
2.5 Ft.
-
FL
SEPARATIONDISTANCES
Total absorption area:
420
umber of trenches:
1
Dist between trenches:
_
To
Septic
Absorption
Lift
Holding
Public/Private
From
Tank
Field
Station
Tank
Sewer
so. Ft.
Ft
Well
100'+/
100'+/
**150'+
100'+/TANK
**150'+
-
25'+
■ Septic ■ S.T.E.P. ❑Holdin ❑ Other
p g
.*150,+
Manufacturer.
capacity.
Surface Water
100'+
100'+
100'+
-
INFILTRATOR SYSTEMS
1530/1060 Gal.
Material:
Number of compartments:
Lot Line
***0'
***3'
5'+
-
N/A
HDPE PLASTIC
Foundation
5'+
10'+
***4'+
-
LIFT STATION
Curtain Drain
NONE KNOWN
Manufacturer. capacity:
INFILTRATOR / QUANICS, INC
1060 Gal.
Remarks: *THIS IS A CAT II QUANICS AEROCELL SYSTEM.
"Pump on' level at
TIMER
Pump off" level at
TIMER
High water alar at
44"
**150'+ TO CLASS "C" WELL LOCATED ON LOT 16. WELL RADIUS STAKED
Pump Make & Model:
Electrical Inspections performed by.
BY REGISTERED LAND SURVEYOR DURING CONSTRUCTION..
PE51 M
M.O.A.
PIPE MATERIAL D1785/
***LOT LINE AND FOUNDATION WAIVER REQUESTED. SEE ATTACHED.
Tank to D2665/
Tankold
House to tank D3034 D3034
drain
Installer WILCO EXCAVATION
Drainfield D3034 CO/MT D3034
Inspector GEG, Ltd.
BENCH MARK (Assumed elevation)
99.90 Ft
Inspection
Dates: 1st 11/10/2015 2nd 11/11/2015
Location and Description:
3rd 11/11/2015 4th -
BOTTOM OF SIDING @ POINT "B"
Community Development Department Approval
ENGINEER'.1 SEAL
OF 4444°°
Conditional approval: Date:
AV' :' � .. °#
.4...... .moi... ..................
o
........
- Mill
yA.nss..:.
Cj
6)/CE-7953
_.
:
Approved: /rU G Date: I �Z
YVAJ `�®•�
LICENSE,1VAI
#AECC884
Inspection Repart_1-1-12doc
I131 PARCEL ID NUMBER:OSP55RECORD DRAWING
011-134-24
A B I C
FCO
54.8
23.6
36.2
ST1
64.0
19.0
40.2
ST2
73.3
12.8
37.8
DBL1
75.7
12.4
38.1
DBL2
76.5
12.5
38.4
MH
78.6
7.0
33.1
POD1
91.5
1 13.3
23.0
PGD2
91.3
12.0
26.1
C01
92.3
12.8
29.8
CO2
92.3
16.7
39.5
MT1
91.6
15.2
37.8
CO3
93.9
21.6
15.4
MT2
95.2
22.0
16.7
SAND LAKE S/D #2;
\ BLOCK 5, LOT 12
\ \ 1
�o \ I 1
w -' \ ► i
a m \\ I l
N I I 1 1
Irrl
II
'm0 / I
I
m
Wi
N
/ /
SCALE:
1"=30'
/ NEW 1050 AEROCELL UNI'
SAND LAKE S/D #2;
BLOCK 5, LOT 16
SAND LAKE S/D #2;
BLOCK 5, LOT 15
I l.i"PGP�/
I
NEW 1060 GALLON
INFILTRATOR TANK
(SINGLE COMPARTMEI
0' WAIVER FOR
TANK REQUESTED-
' WAIVER FOR
DRAINFIELD
REQUESTED _
I
I
w
wNy
(n
/ I
THE RESERVE SITE SHALL BE I /
REBUILDING THE PROPOSED /
DRAINFIELD. I /
ANEW 1530 GALLON
INFILTRATOR TANK
(SINGLE COMPARTMENT)
CONTRACTOR INSTALLED
LARGE BOULDERS TO PREVENT
TANK FROM BEING DRIVEN ON.
(SEE ATTACHED PHOTOS)
cl
i ..
PH
N
4'+ WAIVER FOR
LIFT STATION NEW 4 BEDROOM DUPLEX
TO FOUNDATION
DRAINFIELD
LANCASTER TRACT A
UNDEVELOPED
APPROXIMATE LOCATION OF
WATER LINE AND KEY BOX -
wl
I
CD
Q
I /
I
I
I I
I
I
1 I
200 FOOT
WELL RADIUS ----?I
I
II
II
I
I I
T -
\
HYDRANT \
-APPROXIMATE LOCATION OF WATER
MAIN PER AWWU RECORD DRAWINGS
GARNESS ENGINEERING GROUP, Ltd
CIVIL & ENVIRONMENTAL ENGINEERS -_-
3701 E. TUDOR ROAD, SUITE 101 -ANCHORAGE, AK 99507 • PHONE (907) 337-6179' FAX (907) 338-3246' WEBSITE: www.gamewengineering.eom
PREPARED FOR: PHONE NUMBER: PAGE NUMBER:
WILCO CONTRACTORS 242-5443 2 OF 3
PROJECT/LEGAL DESCRIPTION: DRAWN BY:
SAND LAKE S/D #2; BLOCK 5, LOT 13 J.L.M.
TYPE OF WORK: DATE:
�, RECORD DRAWING OF SEPTIC SYSTEM 1/2/2017
'
w
wNy
(n
/ I
ANEW 1530 GALLON
INFILTRATOR TANK
(SINGLE COMPARTMENT)
CONTRACTOR INSTALLED
LARGE BOULDERS TO PREVENT
TANK FROM BEING DRIVEN ON.
(SEE ATTACHED PHOTOS)
cl
i ..
PH
N
4'+ WAIVER FOR
LIFT STATION NEW 4 BEDROOM DUPLEX
TO FOUNDATION
DRAINFIELD
LANCASTER TRACT A
UNDEVELOPED
APPROXIMATE LOCATION OF
WATER LINE AND KEY BOX -
wl
I
CD
Q
I /
I
I
I I
I
I
1 I
200 FOOT
WELL RADIUS ----?I
I
II
II
I
I I
T -
\
HYDRANT \
-APPROXIMATE LOCATION OF WATER
MAIN PER AWWU RECORD DRAWINGS
GARNESS ENGINEERING GROUP, Ltd
CIVIL & ENVIRONMENTAL ENGINEERS -_-
3701 E. TUDOR ROAD, SUITE 101 -ANCHORAGE, AK 99507 • PHONE (907) 337-6179' FAX (907) 338-3246' WEBSITE: www.gamewengineering.eom
PREPARED FOR: PHONE NUMBER: PAGE NUMBER:
WILCO CONTRACTORS 242-5443 2 OF 3
PROJECT/LEGAL DESCRIPTION: DRAWN BY:
SAND LAKE S/D #2; BLOCK 5, LOT 13 J.L.M.
TYPE OF WORK: DATE:
�, RECORD DRAWING OF SEPTIC SYSTEM 1/2/2017
PERMIT NUMBER:
OSP151351
ST1
TOP OF TANK
(INLET) = 94.8E
OPERATING
LIQUID LEVEL
NVERT OF INLET = 94.26
PARCEL ID NUMBER:REC®R® DRAWING
011-134-24
NOTE: TANKS HAVE 3.81 TO 4.18 FEET OF COVER OVER TOP OF TANKS.
2" OF INSULATION PROVIDED OVER TANK. TANK AREA HAS TOPSOIL
AND HAS ESTABLISHED GRASS GROWTH (SEE ATTACHED PHOTOS)
ST2
0
FINAL GRADE =
2" OF INSULATION OVER TANKS
(PER CONTRACTOR) — ,.
IM -1530 GALLON SINGLE
COMPARTMENT INFILTRATOR TANK
INVERT OF OUTLET =
FINAL GRADE = 98.
-TOP OF TANK
(OUTLET) = 94.89
TOP OF TANK
(INLET) = 94.6E
4" BY 4' WIDE RIGID
INSULATION CENTERED
OVER PIPE
(PER CONTRACTOR)
TOP OF LID = 99.03
IM -1060 GALLON SINGLE 11
COMPARTMENT INFILTRATOR TANK
INVERT OF INLET = 94.02
C01
MT1 CO2
ORIGINAL GRADE = 99.16 MT2 CO3 TOP OF LIDS = 100.53-100.57
(@ HIGHEST POINT) __\n n 7 --FINAL GRADE = 100.44-100.73
FABRICS--{�—Q 0
FILTER TREATMENT MODULE
MUM DEPTH OF EXCAVATION = 89.16
RELATIVE ELEVATION OF TH#1 = 83.16 (NO GROUNDWATER)
TOP OF LIDS = 100.53-1
QUANICS AEROCELL 1050
TREATMENT MODULE
WITH INTERNAL DIVIDER
WALL AND CLEANOUTS
4" BY 4' WIDE RIGID
INSULATION CENTERED
OVER PIPE
(PER CONTRACTOR)
C01
1.25" SUPPLY LINE TO
2" RECIRCULATION LINE DRAINFIELD
TOP OF TANK
(OUTLET) = 94.65
HIGH WATER FLOAT @ 44" FROM BOTTOM OF TANK
TIMER OVERRIDE FLOAT @ 40" FROM BOTTOM OF TANK
LOW LEVEL CUTOFF FLOAT (ON/OFF) @ 36" FROM BOTTOM OF TANK
GOULDS PE51M
AF
v
w ch
m It
M
O
N
Z
2 L
z0
zJ
00
wN
Z0,t
0W Ce)
��
o
Iw-`_
a
a.
0
a
O a
Q
I�
w
W
zuj
Z9
J
W m
J�
LL
Z
Z.
w
Z
��
Zi
O
M
1-1Z.
W
ui=
O
W
J
-�
J
Z J"
U
Y
O
T� oo
Vl
m
Q
—
;
N
Wcl
U
Z WO
0
LL
YLUJ
o
~
0Q
w Z
0 L
L O
u
Q
0
c
in
a
Jw
�
Municipality of Anchorage.'
Orent
(IN
P.O. Box 196650 • 4700 Elmore Road
Anchorage, Alaska 99519-6650 a (907) 343-7904 ® Fax (907) 343-7997
http://www.muni.orci/Onsite
Development Services Division
On -Site Water and Wastewater Program
* * * * VARIANCE/WAIVER REVIEW * * * *
Waiver#: OSV211000 COSA#: Permit#:OSP151351
PID#: 011-134-24
Legal Description: SAND LAKE #2 BILK 5 LT 13
Engineer: Garness Engineering Group
Your request for a waiver of the required horizontal separation from the
absorption field and septic tank to the property line has been approved. The approved separation
distance is 0.0 feet for the tanks and 3.5 for the field. In addition, the tank is allowed to remain 4.7
feet to the foundation.
This waiver .approval applies to the existing absorption field and septic tank only. Any future
upgrade to the on-site wastewater disposal system will require all separation distances be met or
another approval from this department.
Waiver is Granted: X Waiver is not Granted:
Date: Z Approved by: a
Name of Revie
**** VARIAN C E/WAIVER REVIEW ****
GARNESS ENGINEERING GROUP, Ltd
CIVIL & ENVIRONMENTAL ENGINEERS - - — -
January 2, 2017
Municipality of Anchorage
Development Service Department
On -Site Water & Wastewater Program
4700 Elmore Road
Anchorage, AK 99507
Qui-a�{c
r
Advan«�d Treatment Sy
--rr_tom
�r
D
Ref: Lot Line and Foundation Waiver Request for Sand Lake S/D #2; Block 5, Lot 13
Lot Line Waiver: The new 4 bedroom duplex was issued a septic permit on October 22,
2015. At the time of the issuance of the permit, the property was proposed to have the lot
line removed between Lots 13 and 14. The new septic system was installed in November
of 2015 with this in mind and no lot line waiver was issued with the permit. We have
completed the documentation of the new septic system and the lot line between lots 13
& 14 has not been removed through a platting process. Based upon this information, we
are requesting a 0 foot lot line waiver to the new septic tanks and a 3.5 foot waiver from
the new drainfield to the North lot line of Lot 13 be granted. Lots 13 and 14 are owned by
the same owner and they have no objections to the granting of these waivers.
Foundation Waiver: The new septic tank and lift station were installed prior to the
foundation being installed. During our inspection, we physically measured to the staking
for the foundation to the tanks and there was over 5 foot separation to the proposed
foundation. We have performed the swing -ties for the record drawings and we found that
from the center of the manhole riser for the lift station to foundation was right at 7 feet.
Based upon the drawings for the Infiltrator tanks, the measurement from the center of the
manhole to the very edge of the tank is 27.5 inches (2.29'). This would make the edge of
the tank 4.7 feet from the foundation. We are requesting a 4 foot waiver be granted for
the lift station. Since this tank is only 0.3 feet short of meeting the separation distance
requirement, it is our opinion that there is minimal risk with the granting of this waiver.
We are unaware of any adverse impacts this installation would have on adjacent wells or
septic systems. If you have any questions, please contact us at 337-6179. Thank you
fnr vni it acciQtnncA
M.S.
3701 East Tudor Road, Suite 101 * Anchorage, Alaska 99507-1259
Phone: (907) 337-6179 * Fax: (907) 338-3246 * Website: www.garnessengineering.com
C
C)
Cl)
ops
ua
Cl)
Cc) CO ro
zm
to Co r4D Go
E
ci
CN
C)
rc
Q
uj
LO
Ile
i
CN
Q
LIU,
ZE
LIJ
uj
iz
CO
C
C)
Cl)
ops
ua
Cl)
Cc) CO ro
zm
to Co r4D Go
E
ci
I �
SEAVIEW STREET
P
-
w 0
i J.
•
• ° .
Mat
0.a �a
`•
5 OV06'00®E 50.00' cn
Z Q
�� N mZ �� O
U w .6'£ t 26X .6.6 N a a O:
.- .9C O
x O x
b. m.C® ° edo ® c
M ®W.to' E Q A C
N ® V3 ��+�® ®g
O� Nto,?.a p�
{�IQ .�pO C
CN
_ ow '01
�' O n
1r3 O M'j O m ®
N �J �¢N�BN� ®��I- Ga
H O a C1 0C ®O:E ®a
r
IS
m m ®�hh ® ta. O
m��7j � coo
�+.D > ®� 6 Vcc
U 0 w .0•�
• Q r"a O - w ® ems..-�
in pb
28.2' 2cc � Q
• ate.- � .
Q ® 0 a�
• N O ® O
C Coo
XI La
N 00°0600 50.00 m a.0 -
®�g�
C "�
Qi
-w
IL ® al
-- ® zn
v m�I A E ® 3
C
On-Site WaStewater Disposal System Permit
MUNICIPALITY OF ANCHORAGE
Development Services Department
On-Site Water & Wastewater Program
4700 Elmore Road, PO Box 196650
Anchorage, AK 99519-6650
Telephone: (907) 343-7904
Permit Number: OSP151351
Tax Code Number: 01113424000
Work Type: Septic Initial
Permit Effective Dates: October 22, 2015
to October21,2016
Design Engineer: GARNESS ENGINEERING GROUP LTD
Subdivision: SAND LAKE #2
Site Legal Address: SAND LAKE #2 BLK 5 LT 13 G:2224
Owner/Address: WILCO CONTRACTORS
16701 RANSOM RIDGE ROAD ANCHORAGE AK 995165347
Site Mailing Address:
Lot Size in Sq Ft: 6750
Total Bedrooms: 4
This permit is for the construction of:
Y Disposal Field Y SepticTank N Holding Tank N Privy N Private Well N Water Storage
All construction must be in accordance with: 1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater
Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80).
3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services
Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either:
A. Open and Close on the same day.
B. Covered, sealed, and heated to prevent freezing.
Received
Issued By:
MUNICIPALITY OF ANCHOI
Community Development Department
Development Services
On-Site Water & Wastewater Program
Mayor Dan Sullivan
(: 907- 343-7997/
On-Site Sewer/Well Permit Application
For A Single Family Dwelling
Parcel I.D. O1~ '-~,"2'¢k'~"'2~
Property owner(s) WILCO CONTRACTORS Day phone
242-5443
Mailing address NHN SEAVIEW STREET *ANCHORAGE~ AK -
Site address NHN SEAVIEW STREET ~ANCHORAOE, AK
Legal description (Sub'd, Block& Lot)SAND LAKE #2; BLOCK 5, LOT 15
Legal description (Township, Section & Range)
Lot Size Sq.Ft, Number of Bedrooms 4
APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DEWELLING:
( [~_11 that apply) Initial [] Single Family (SF) []
Absorption Field [] (w/wo ADU)
Septic Tank [] Upgrade []
Renewal [] Duplex (D) []
Holding Tank [] Multiple Dwellings []
Privy [] (SF and/or D)
Private Well []
Water Storage []
THIS APPLICATION INCLUDES A VARIANCE/WAIVER REQUEST FOR:
N/A Distance:. -
I certify that the above information is correct. I further certify that this is in accordance with
applicable Municipal codes.
GARNESS ENGINEERING GROUP, Ltd.
(Signature of property owner or authorized agent)
Permit/Rush Fees:
Date of Payment:
Receipt Number:
Permit No.
,~ ~ Waiver Fees:
/O - /~'~/,~;~'"' Date of Payment:
0 ~""~ I 0 (~N Receipt Number:
?/'5 / Weaver No.
(Rev. 01/11)
GARNESS ENGINEERING GROUP, Ltd
CIVIL & ENVIRONMENTAL ENGINEERS
October 16, 2015
Municipality of Anchorage
Development Service Department
On-Site Water & Wastewater Program
4700 Elmore Road
Anchorage, AK 99507
Ref: Proposed Septic System for Sand Lake #2; Block 5, Lot 13 & 14
To whom it may concern:
The subject property is currently vacant. The developer is proposing to install a 4 bedroom
duplex (2 bedrooms each side). The lots are served by AWVVU water. Because of the limited
space for the initial and/or future septic systems on the property, we are proposing a Cat II
Quanics Aerocell treatment system be used which will consist of a 1530 gallon infiltrator septic
tank (single compartment), a 1050 gallon Infiltrator tank (single compartment) with Quanics
pumps & controls, and a 1050 Aerocell pod. One testhole was excavated on the property and
the drainfield is designed within the 30 foot radius. Comments regarding the design are
summarized as follows:
1. SOILS: See the attached 2013 soil log which show the soil classifications, groundwater
monitoring, and the percolation test results.
2. DRAINFIELD DESIGN: See attached design drawing for drainfield specifications.
3. SURFACE WATERS: There are no surface water concerns.
4. TOPOGRAPHY: As can be seen on the attached design drawing, the average topography
around the proposed drainfield is generally flat.
5. WAIVER: Given the visual classification (SVV) of the native soil, we are requesting that your
department waive the need for a sand filter.
We are unaware of any adverse impacts this installation would have on adjacent wells or septic
systems. If you have any questions, please contact us at 337-6179. Thank you for your
assistance.
Preside~/ x,j
3701 East Tudor Road, Suite 101 * Anchorage, Alaska 99507-1259
Phone: (907) 337-6179 * Fax: (907) 338-3246 * Website: www.garnessengineering.com
___~ ........ ~-/- ..... = ............... 1 .......................... ~ ..................... ,/ ........
~ /
LANCASTER TRACT A
UNDEVELOPED
GARNESS ENGINEERING GROUP, Ltd
~ 100 SCALE SEPTIC SYSTEM DESIGN UPGRADE 10/14/2015
i
DESIGN CRITERIA:
NUMBER OF BEDROOMS: 4
GALLONS PER DAY (GPD): 600
PERCOLATION RATE/S: <1 MIN/INCH
PROPOSED APPLICATION RATE: '4.0
*CAT II ADVANCED TREATMENT
__ MINIMUM DRAINFIELD SQ, FT,: 150
DRAINFIELD DESIGN:
MAXIMUM DEPTH OF EXCAVATION: 10 FEET
WIDTH: 2.5 FEET
LENGTH: 30 FEET
M.O.A. APPROVED SAND FILTER:
PROPOSED USE OF IN-SITU SOILS
EFFECTIVE: 7.0 FEET
ACTUAL SQ.FT.: 420 FT~
SAND LAKE S/O ~2;
. BLOCK 5, LOT ,0
,.STALL
%PROP6SED 1530 GALLON
INFILTRATOR SEPTIC
PROPOSED 1060 GALLON
SINGLE COMPARTMENT
--'----" INFILTRATOR PUMP TANK -
\ \
\
~ROPOSED DRAINFIEL~ -~
SAND LAKE S/D #~
~_~OCK 5. EOT 1~
PROPOSED 1050
AEROCELL TREATMENT
UNIT ~
EXISTING
/I
/ /
SAND LAKE S/D ii2;
BLOCK 5, LOT 12
/ /
/ /
/ /
/
/,
GEG, Ltd. HAS ~ B PAGE BPECIFI ION
LETTER THAT PERTAINS TO THIS DESIGN.
TO OBTAIN A COPY OF THE LETTER THE RESERVE SITE SHALL
CONTACT GED. BY PROCEEOING FORWARD BE REBUILDING THE
WITH THIS NSTALLATON, THE ENDNEER. PROPOSED DRAINFIELD
WELL DRILLER, CONTRACTOR AND I
PROPERW OWNER AGREE TH/~ THEY -
HAVE READ THESE SPECIFICAT,ONS AND -- --
AGREE TO ACCEPT THE TERMS AND
NOTE'. THE CONTRACTOR
SHALL HAVE THE SOUTH &:
WEST LOT LINES, AND ALL c~. ~ I
WELL RADII FLAGGED BY A ~ SC~E:
REGISTERED LAND SURVEYOR
PRIOR TO CONSTRUCTION.
SAND LAKE S/D J~2:
BLOCK 5, LOT 15
/
/
/
1" -- 40'
/
/
I/
/!
PROPOSED 4 BEDROOM DUPLEX WILCO
LOCATION
OF AWWU HYDRANT
I
~APPROXIMATE LOCATION OF WATER
MAIN PER AWWU RECORD DRAWINGS
LANCASTER TRACT A \
UNDEVELOPED \
\
GARNESS ENGINEERING GROUP, Ltd
~Z
O~
O0
z
GARNESS ENGINEERING GROUP, Ltd
CIVIL & ENVIRONMENTAL ENGINEERS
[SOIL LOG - PERCOLATION TEST]
LEGAL DESCRIPTION: SAND LAKE S/D #2; BLOCK 5, LOT I3
PERFORMED FOR: WILCO CONTRACTORS
DATE: 10/15/2013
ORG
[TEST HOLE #1 [
SOIL CLASSIFICATIONS
GH
SW BLACK SAND
W/SOME GRAVEL
PRESENT
OR
HL
CL
OL
MP
CH
OH
SC
DEPTH TO
GROUNDWATER DATE
DRY 10/15/2013
DRY 10/22/2013
DRY 1013/2015
SITE PLAN
SCALE:
DATE READING CLOCK NET TIME WATER LEVEL NET DROP
TIME (MINUTES) READING (INCHES)
10/15/2013 PERK TEST ABSORBED 5 GALLONS OF WATER IN LESS THAN 3 MINUTES 3V'~3 TIMES
PERCOLATION RATE <1 (MIN./iNCH) PERC. HOLE DIA, (INCHES)
TEST RUN BETWEEN 5.0 FT. AND 6.0 FT.
A FOUR HOUR PRESOAK WAS PERFORMED: [] YES · NO
SOILS LOGGED BY: ANDREWGRAY PERCOLATION TEST PERFORMED BY: ANDREW,GRAY
EOHHENTS: PERCOLATION READINGS ARE WITHIN 1116 OF INCH.
PERFORMED BY GEG, Ltd. I, JEFFREY A. GARNESS, CERTIFY THAT THIS WAS PERFORMED~.IN ACCORDANCE
WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE: ~'~ ~! .,~/,'?
ADVANCED WASTEWATER TREATMENT SYSTEM
MAINTENANCE AND REPAIR AGREEMENT
BETWEEN MUNICIPALITY On('' F ANCHORAGE
AND ( ,liLV 149 ,
THIS MAINTENANCE AND REPAIR AGREEMENT made and entered into as of this
20 Day of Oadpc.r of 2015 , by and between (etc Q 1A -r.. tA)A l
herein the "OWNER," and the Municipality of Anchorage, herein the
"MUNICIPALITY." In consideration of the mutual covenants contained herein, the
parties to this Maintenance and Repair Agreement agree as follows:
1. Advanced Wastewater Treatment Systems. Municipality grants permission to
Owner to utilize and operate an Advanced Wastewater Treatment System
(AWWTS), described as
Qwp1 )
located at (legal description).
Some� ko. # 9 i 13
2. Definitions.
Alteration. Any change to the design or function of an AW WTS that
includes the installation or removal of any parts, components or pieces not
included in the original construction permit and design.
Certificate of On -Site Systems Approval (COSA). An approval by the
Municipality of existing water and wastewater disposal systems given at
the time of property sale and title transfer in accordance with Anchorage
Municipal Code (hereinafter, "AMC') 15.65. These approvals certify that
the systems are adequate for the homes that they support and meet the
codes that were in place at the time of system construction.
Damage. Any man-made or natural change in a system that would inhibit
the system from performing as designed.
Maintenance and Repair. The scheduled and as needed replacement of
existing parts, components and pieces of an AWWTS that were included
in the original design which would allow the AWWTS to continue to
perform as designed.
Permit. An On -Site Wastewater Disposal Permit as required by AMC
15.65 to construct and operate an AWWTS.
3. Term. The term of this Maintenance and Repair Agreement shall begin on the
date of approval by the Municipality to operate the installed system or issuance of a
COSA, and shall continue while the AWWTS is in use or is operational or until the
property is sold or title is transferred by the owner and a new COSA is issued to the
new owner or transferee of the property.
4. Alterations. Installation and Removal of Additional Eauioment. Prior to
performing any alterations to an AWWTS, the owner agrees to obtain an On-site
Wastewater Disposal Permit from the Municipality in accordance with AMC 15.65.
5. Maintenance and Repairs.
A. Throughout the term of this Maintenance and Repair Agreement, the Owner shall
maintain their AWWTS in a satisfactory condition capable of producing treated
septic effluent in accordance with the equipment's approval for operation in the
Municipality. The owner shall enter into a service agreement with an AWWTS
H. Owner agrees that the AWWTS installation and maintenance requirements as
provided by the AWWTS vendor/installer and approved by the Municipality are
the governing guidelines for the construction, maintenance and repair of the
Owner's AWWTS.
6. Nonwaiver. The failure of either party at any time to enforce a provision of this
Maintenance and Repair Agreement shall in no way constitute a waiver of the
provisions, nor in any way affect the validity of the Maintenance and Repair
Agreement or any part hereof, or the right of such parry thereafter to enforce each and
every provision hereof.
7. Amendment.
A. This Maintenance and Repair Agreement shall only be amended, modified or
changed by a writing, executed by authorized representatives of the parties, with
the same formality that this Maintenance and Repair Agreement was executed
with, and such writing shall be attached to this Maintenance and Repair
Agreement as an amendment.
B. For the purposes of any amendment modification or change to the terms and
conditions of this agreement, the only authorized representatives of the parties
are:
a. Owner:
b. Municipality: Director Community Development or designated authority
C. Any attempt to amend, modify, or change this contract by either an unauthorized
representative or unauthorized means shall be void.
8. Jurisdiction: Choice of Law. Any civil action arising from this Maintenance
and Repair Agreement shall be brought in the Superior Court for the Third Judicial
District of the State of Alaska at Anchorage. The laws of the State of Alaska shall
govern the rights and obligations of the parties under this Maintenance and Repair
Agreement.
9. Severability. Any provisions of this Maintenance and Repair Agreement decreed
invalid by a court of competent jurisdiction shall not invalidate the remaining
provisions of the Maintenance and Repair Agreement.
OWNER:
r
%�
By: �?'r�l+ «"signature)
Date: it j c
cja, xY. (print name)
'',\Y N G,4
_
t4✓
NOTAq Y
STATE OF ALASKA
AUB
SS.
i o •N.LIG R't
�4�°
THIRD JUDICIAL DISTRICT )
%"OF ALP"')
Aq, eicoes.- 41
The foregoing instrument was acknowledged before me this dayloy-111Ekyt
2015,by IiJliQjAh(UVASM
q&� �tAdLAQ,
NOTARY PkJBLIC FOR ALASI
My Commission expires: g - a , D-0 19
MUNICIPALITY:
signature) Date:
name) Title: