HomeMy WebLinkAboutRAPTORS KNOLL LT 1Raptors Knoll Lot I #017-101-58 Municipality of Anchorage Community Development Department Page 1 of 2 On-Site Water and Wastewater Program 4700 Elmore St. • P.O. Box 196650 Anchorage,AK 99519-6650• http://www.muni.org/onsite•(907)343-7904 ON-SITE WASTEWATER INSPECTION REPORT Permit Number: OSP181036 PID Number: 017-101-58 ❑✓ New ❑ Upgrade Name: RAPTOR PROPERTIES LLC ABSORPTION FIELD Address 0 Deep Trench ❑ Shallow Trench 0 Bed 0 Mound RAPTORS KNOLL CIRCLE ❑ Other Phone Number of Bedrooms Soil Rating Total depth from original grade 3 0.6 GPD/SF 12.5 Ft. LEGAL DESCRIPTION Depth to pipe invert from original grade Gravel depth beneath pipe Subdivision Block Lot 2.0 Ft. 10.0Ft. RAPTORS KNOLL 1 Fill added above original grade Gravel length Township Range Section 2.0 Ft. 40 Ft. Gravel width Beds:Number of Lines Distance between lines SEPARATION DISTANCES 2.5Ft. N/A N/A Ft. To Septic AbsorptionHolding Sewer Total absorption area Number of trenches Dist.between trenches From Tank Field Lift Station Tank Line 800 Ft2 Ft. Well 119.1 123.3 N/A N/A 74.1 TANK O Septic ❑S.T.E.P. ❑Holding 0 Other Manufacturer Capacity Surface water 100+ 100+ N/A N/A GREER 1000Ga1. Material Number of compartments Lot Line 21.9 10.8 N/A N/A PLASTIC 2 NA - Foundation 59.5 68.3 N/A N/A LIFT STATION Manufacturer Capacity Curtain Drain 50+ 50+ N/A N/A Gal. I Pump on level at Pump off level at High water alarm at Remarks in. in. in. Pump make and model Electrical Inspections performed by PIPE MATERIAL House to tank 3034 Tank to 3034 Installer drainfield POMRAINGING EXCAVATION Drainfield 3034 CO/MT 3034 Inspector PANNONE ENGINEERING SERVICES BENCH MARK (Assumed elevation) 84.0ft Inspection iv Location and description dates: 1 10/18/18 2,., 10/19/18 Td 10/19/18 4'" 12/6/18 NW BOTTOM HOUSE TRIM COMMUNITY DEVELOPMENT DEPARTMENT APPROVAL Engineer's Stamp �t Conditional Approval: Date ��P,�(.OF A(,Qs��l+ St ,.. ;I5annorae kr r0} :* 814 ,Approved '� . 6WS Date 41/18 �k� 2C +i'CC4 tt a�A.,� holt Tim �c k 1 uilA Inspection Report_1-1-12.doc V * SITE NOTES: 1. DRIVEWAY LOCATION SHOWN IS FROM DEVELOPER'S PLOT PLAN. PES DID NOT DESIGN DRIVEWAY AND IS NOT RESPONSIBLE FOR IT'S LOCATION. THE DRIVEWAY WILL BE CONSTRUCTED ABOVE ORIGINAL GRADE AND WILL NOT CREATE ANY CUT SLOPES ON THE LOT, ABOVE OR BELOW THE SEPTIC SYSTEM. 2. RETENTION BASIN IS REQUIRED BY PLAT. THE BASIN WILL BE NO MORE THAN 2 FEET DEEP. THIS LOT IS TYPIFIED BY DRY WOODLAND VEGETATION, WITH WELL PERCOLATING SOIL. IT IS NOT LIKELY THAT THIS RETENTION BASIN WILL EVER CONTAIN WATER. 3. ANY SLOPE WITHIN 50' OF THE DRAINFIELD WILL BE AT 4:1 OR FLATTER. DESIGN PARAME ERS -„ INSTALLED BRAIN FIELD PRIMARY SEPTIC SYSTEM \I s.\ W 4OLF x 2.5'W x 10.0'ED x 12.5'TD' NO. BEDROOM: 3 (450 gpd) 4 `"I-W \ INSTALLED CLEAN OUT AND / amt, TANK SIZE: 1000 MONITOR TUBE AT EACH END PERC RATE: 17 MPI oz \ \ i -� SOIL RATING: 0.6 GPD/SF D RESERVE DRAIN FIELD P AREA RQD: 1000 SF I o J .ES •co T.-10LF x 2.5'W x 10.0'ED x 12.5'TD SYS. TYPE: DEEP TRENCH 10.0'ED w 0' BASED ON CAT III MIN LENGTH: 37.5 LF \ o ��_ 1 1 11-1-2 1. USED: m ANDERSON INSTALLED 1000q SEPTIC TANK = 40 LFx2.5'Wx10.O' E.D., 12.5' TD o \ �` W/ FOUNDATION CLEAN OUT BEFOR§ TOTAL AREA: 800 SF \ T, r t AND DCO AFTER � � F , , , Jj. \ DESIGN PARAMETERS RESERVE SEPTIC SYSTEM i tai n ` -J I 4 NO. BEDROOM: 3 (450 gpd) 1 \ Vi%TANK SIZE: 1500 ADVANTEX __ ci DRIVEWAYBR \ \ o1N/ AX20 POD -Ni --~ \ USF • PERC RATE: 17 MPI w�M ` 1i �`E A B SOIL RATING: 4 GPD/SF \ \ AREA ROD: 150 SF z FC 3.5 51.6SYS. TYPE: DEEP TRENCH 10.0'ED v fid' \ � Ti 62.1 95.1 MIN LENGTH: 5.6 LF . ` T2 63.2 99.2 O • I RETENTION BASIN SEE NOTE 2. \ • MT 60.8 98.1 USE: Y 10 LFx2.5'Wx10.0' E.D., 12.5' TD \ \ L . \ WEA-y` DCO 66.5 101.6 TOTAL AREA: 200 SF o Cl 69.6 97.6 /J_ \ M1 70.7 98.5 __,7c%. \ ` ! 10' UTILITY EASEMENT C2 105.0 138.8 s'/ N M2 1424.6 1 138.0 z o'- F- -- > D <0 0 0 a aa zzQ ,,,Zo .2 m z3 ) T< O ~ 1.0 U 0 $u i o1 FILTER FABRIC 2. - _ OC.FC. _ _, c, Z a 79.0 u 2 DRAIN ROCK 6"ABOVE PIPE INV 0 6 // 4o ORA!N PIPE F.C.78.0 - O.C.76.0 t R+ -1.0 �'• i• is i• i i �• 74.4 74.2 CONNECT �T.'.11:$��,:e-•,• .��••t♦`Y•� ��•� To mom 'v`j`[�',X``.tiX�:� iX.�, �-��i. -2.0 1000 g SEPTIC TANK ' •4.•4.•_I •~10.0•DRAIN ROCK•�,�•a,a, at c 4 OF DRAIN .Y. . {X, . FIELD +0110a04.. ..4.,1..i•11, 00A, PROFILE •rir,_.r�.r,Y� 0 -:�X x*-�!Y.,!z.4T e< SCALE:NTS *4,i.,i1i.1i,4,4"41 y4r��'P'1 I CM 7401 i o�Y{•-NZ", *y;v."VT ,' 4"foe+,• '. X Y; 7;,sc DRY:5/15/13 • -15.0 CM 1 ---1 -18.5 DATE PERFORMED: NOTES: �����.\` Dote RECORD DRAWING PANNONE ENG SVC, LLC qF AL. ,k 12/17/2018 P.O. BOX 100217 ANCHORAGE, AK 99510 S PHONE (907) 272-8218 FAX (907) 272-8211 %ri" .:' '•�-yr1 ScaIe ••• ... .. ••• .... / P.I.D. NO DRAWN: ACP RAPTOR'S KNOLL, LOT 1 -101-58 RAPTOR PROPERTIES LLC StevenFR. Pennome PERMIT NO RAPTOR'S KNOLL CIRCLE �n•. C- 8149 i// 0SP181036 II PLAN ANCHORAGE, AK 99516 1kt`"PF�!'R •.•.0Na�c ~ Sheet `���\zi�� 2 OF 2 • ncc co:t3 „;?;xSC.i t C,0S.k ;kl, Ill Lit/A ... wAvoi viftiFL .; s . 0....,....‘; ,.;:.j ' .‘4•a:X:a1,01t+A:tt446.40-,V.WAYOMI9CMCIOMOXIM-Pr.XIMMI0.VA .14..SGb.AEMI2tXrwxliMrl y. P.O.Bar.670269.Chhuglak,Jc J. u6? rlil V.-2? $ • Ci'r•L'i: i:.);- L•',^>:: Spinel#Home.> x LEGAL DESC?i3r T iri.',? ;{apti.x(s Knri i.-t:t?. Soto ri-stt 1. .42 ., DATE: 7-9-.o e PE'':(ili P;LjM I:R: osP1a1t13'.'; DA 07`SSti+_: MS/29/1 Depth� ' F,"am To ' TA IDF 'TIFIC�,TiON NUM Eli. ('',"101 ZC=iO - --- • i5 well icicati_'d ct approved permit!Oi.4+tiCt!l: Yi �;o_ - i.. ..-.._. E-....___.._ Casing �t ___ _-_-..__.,..-.._ ___.-..-.-_ Method c Dftii:>? aSr rotary ! jtiilf f?tow: `_. ...___.__< ___� _ _ - -_ Depth, s Weil: :; i 4 ' 64 Silty Sand&GI-aye; Casing Type: Ste,e! '__W?.,2rtirk.^.ess .2501 incP!es 64 i `.. 81 ...., -iiia yard&Grave _ __.l _._ _ Diameter: 6 rin . inches, der , : c.: fee>_ S ___ 81 104, Hardpan Staii flat}f Lev'_,. _-..._._._..-------..._.____Y._Q" ---- '• 104 'tiner type 200' 4.5" PVC 110 :.lav i `rava!W411: - Racoven 'tte. i.5 :/ vpr i oh i { ..._ Silty Sand& 4ra,ei Damp, ____ — I _ _ _i'i';hQ =ii Te,i'; t {i: 3.49 1555 .i.lj,nrSilt S. &Cra's'Pl 1t,1 Ci::t.'!R et Type:Y'.' Si if'i2n OpeningyType:1 �'�^r,:,$:i!) li !)I !hole. ' .;:.._.ASS 167 ___ _—_................ r---, r e',<,�v t .. t? c- u a :i I..—: Screened S'tx"!rtii'.£:t Stopped 167 Bearo • < Gen GrayF � P ,fTrati.7c SE.r1e S':4 Ci .. 260 i 292 Bedrock Gray w/Qua;tGroat Type: B2 i7tlt: Volume.: 3n i; Depth:from ___.._ ...._........ f2 feet a 340Bedrock Gray 2.�iafti r Well Lisinfecteo upon Cor< :etian• ve!, i no _. _. .....Method of oof Disinfection•' Chlorine SC PPM Ccr,IhsG i ts: • h. J.`-.!:-3. 5 2 GPM(left curs'-rit'•,slightly ightl`I above bedrock ... i.kflo'w this water to enter vp7.d1 .r a.c dol y to'."daatr r ' :_.._.._..._._._.._.__._._._. ...__.....---- • cemir.g from bedrock below) ...._......._.._.,..._. i • _-.._._...-.-_.-WATER QUALITY-TESTING" ! at e .. Col/100ml- ----- i Arsenic.. .... _ _.._ . ..... - • 1'., FC'ay'':3.i:i)b.:`; i.: _iYo •-'a'..:'s•;'. / .._:FS!?< '.^ s:'.•7;iS'. sv �i . e�;_.i _ viLei 1:�;, :.:� .r:.. _ > % -c^,� -,�x,i•c.:its pili .;r .. .,,:;107.irr Kli.till:V.': :1.i!t. 1 ,'tt!�." . ..friii:' av7 '3 ?F -,..Citi ^i ,. '��^rs?�.... -.R..�. .:_ . --...................- c3 0,.• I...._...:_i,_..,_..i.r.:.i.3hi...,W ...A...,,,....R w...,...ELLs,.., P.O. Box 67025.9.Chucii,. •:,Alf.99567 663-2759 1411.,VW.S tin Iva nwate rweits.co m Pump Instalbtion Log i _ ,...„, Well grilling Perrnit Number:SW OSP1g1035 Date of Issue 3/29118 Parcel ldentification 1,Zumber: 01710158000 li Legal Description 1 Property Owner Name& Address I Raptors Knoli Lot 1 I 5pinell Homes • 1 , 11; . 11 Pump Installation Date: 7-13-19 .11 1 1 Pump Intake Depth Below Top of Well Casing: 310 ,1 Pump manufac-turer's Name: c&w feet : ; ill / Pump Model: 4F07G10301 ei 4! Pump 12 Size: 1 hp • ii Pitless Adapter Burial Depth: 10 feet {! 1 1! Pitiess Adapter Installer: Pomraning Excavation I! il Disinfected Upon Completion? Z. yes Fl no fi 1j Method of Disinfe.ction: Chlorine 50 PPM li gi li 11 11 11 Comments: Pitless Manufacturer:Martinson ,f 11 1! it if 11 ) Pump Installers Name: Sullivan Water Wells 11 il ?if 4ktw,m.oariaaso.rcewxovv...e.w.rxvnr,eeoyrar.*.+eovsaesedga.a:edwr,.nsstv.zsowee,...r.ao...m.Iwv:....Z..dr.ass-aon.Mascwve.C.S.PII.Aae.,TM•.w.w.wnInz4nerozrfca,%e.••15r.rv.an,arAeu.uanVnwaxdliowzsasr--v,vanr.xnaa,wmsztsnrssmnno•avm•oq Attention:The pump installer shall provide a pump instzsliation log to the DSD within 30 days of pump installation. PLAT NO. 2014-128 RAPTORS KNOLL SUBDIVISION LOT 1 44,317 S.F. S 89°58'11"E 320.06' 19....---, s i • 143.3' * ;� Q' Naa SEPTIC SYSTEM . p. M ° ® 2130 -z I rn C.) b laIb t m GRpY4 OR' c kr .1114 I`' co I o c TO Iwrn Y C3 ILL/I- 0 30' i C) i as 0 r VI 0 I 16-:;.?, 0 ce 0 Io O o ?.5 0 20.6 t o O 0 5 z I Z I I I ! 10' UNDERGROUND WELL CEA ROW ESMT. I i (2014-043192-0) I f 1 „ =30' I 10' T. & E. ESMT. 10' UTILITY ESMT. (79-217) O S 89°58'11"E 319.95' 0 M E. 142ND AVENUE AS - B U I L T I HEREBY CERTIFY THAT I HAVE SURVEYED THE PROPERTY DEPICTED ABOVE AND THAT NO GASTALDI LAND ENCROACHMENTS EXIST EXCEPT AS INDICATED. O®® �F14Rah SURVEY ING. LLC IT iS THE RESPONSIBILITY OF THE OWNER TO e®�� °,...° AC JEFF A. GASTALDI. R.L.S. DETERMINE THE EXISTENCE OF ANY EASEMENTS, 4�P ... °° •°°•4_ .�5�®. 2000 E. DOWLING RD., SUITE 8 COVENANTS OR RESTRICTIONS WHICH DO NOT '�' Cr 49TH i\ ° ANCHORAGE, ALASKA 99507 APPEAR ON THE RECORDED SUBDIVISION PLAT. s PHONE 248-5454 UNDER NO CIRCUMSTANCES SHOULD ANY DATA GRID DATE HEREON BE USED FOR CONSTRUCTION OR FOR I. Jeffery A. Gastaldi : o A ESTABLISHING BOUNDARY OR FENCE LINES. O.��^ o(3�I�Pe/elm� SW3037 10/31/2018 s ANCHORAGE RECORDING DISTRICT, ALASKA a® a •......°• F.B. JOB NO. , p"Orass,onot l.°�44 NOTE : NO CORNERS SET THIS DATE „gill. N IS II** 18-03 RAPTOR1 ""T� MUNICIPALITY OF ANCHORAGE aON�--�. Oa \7\l n • � ' On-Site Water&Wastewater Program lispilis,,+I ' r,a„�\ PO Box 196650 4700 Elmore Road 14e. t1Anchorage,Alaska 99519-6650 Phone:(907)343-7904 Fax:(907)343-7997 ,�"' httpa/www.muni.org/onsite 11 g� iii On-Site Water & Wastewater System Permit Permit Number: OSP181036 Effective Date: 3/29/2018 Work Type: WellSeptic Renewal Expiration Date: 3/29/2019 Tax Code Number: 01710158000 Site Legal Address: RAPTORS KNOLL LT 1 G:3037 Site Mailing Address: 14175 RAPTORS KNOLL CIR, Anchorage Owner: SPINELL HOMES INC Lot Size in Sq Ft: 44317 Design Engineer: PANNONE ENGINEERING SERVICES Total Bedrooms: fY 3 This permit is for the construction of: 0 Disposal Field Q Septic Tank 0 Holding Tank 0 Privy II Private Well 0 Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing Special Provisions: PRIOR TO INSPECTION REPORT APPROVAL: Property improvements (driveway, landscaping, etc) shall be verified to not have any 25% or greater slopes within 50 feet down gradient of the drainfield, and that the finish grades provide positive drainage away from the drainfield, i.e.; no ponding at or near the drainfield. C O- 1 3//Mg Des( chanq� 1-0 3 G IWA,5. Received By. ei ' /, ,/ai./L.-.,.�►.t i.Ii.//_/ .4 Date: -6/30/./g / I Date: 3�G/ r° Issued By: ,) . / A. r MUNICIPALITY OF ANCHORAGE Community Development Department ^" Phone: 907-343-7904 Development Services Division Fax: 907-343-7997 On-Site Water & Wastewater Program ON-SITE SEWER/WELL PERMIT APPLICATION Parcel I.D. 017-101-58 Property owner(s) Spinel) Homes INC Day phone Mailing address 1900 Northern Lights Blvd Anchorage, AK 99517 Site address 14175 Raptors Knoll Circle Legal description (Sub'd., Block & Lot) Raptors Knoll Lot 1 Legal description (Township, Range & Section) Lot Size 44,317 Sq. Ft. Number of Bedrooms/ 3 APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (®all that apply) Absorption Field ❑x Initial ❑ Single Family (SF) ❑X (w/wo ADU) Septic Tank ❑X Upgrade ❑ Duplex (D) ❑ Holding Tank ❑ Renewal 0 Multiple Dwellings ❑ Privy ❑ (SF and/or D) Private Well x❑ Water Storage ❑ THIS APPLICATION INCLUDES A VARIANCE /WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit/Rush Fees: � Waiver Fees: Date of Payment: - Date of Payment: Receipt Number: 01' s Receipt Number: Permit No. CJ'PITI 031, Waiver No. Permit App_:-'• ::..,:c: On-Site Water & Wastewater System Permit ,lrf nt ..S‘MUNICIPALITY OF ANCHORAGE �., Development Services Department t. On-Site Water& Wastewater Program 4700 Elmore Road, PO Box 196650 l)(1)a r t m(m t Anchorage, AK 99519-6650 Telephone: (907) 343-7904 Permit Number: OSP151367 Tax Code Number: 01710158000 Work Type: WellSeptic Initial Permit Effective Dates: November 18, 2015 to November 17, 2016 Design Engineer: PANNONE ENGINEERING SERVICE Subdivision: RAPTORS KNOLL Site Legal Address: RAPTORS KNOLL LT 1 G:3037 Owner/Address: RAPTOR PROPERTIES LLC 5725 YUKON CHARLIE LOOP ANCHORAGE AK 995020000 Site Mailing Address: 14175 RAPTORS KNOLL CIR. Anchorage Lot Size in Sq Ft: 44317 Total Bedrooms: 4 This permit is for the construction of: Y Disposal Field Y Septic Tank N Holding Tank N Privy Y Private Well N Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80). 3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours). 4. From October 15 to April 15. a subsurface soil absorption system under construction during freezing weather must either: A. Open and Close on the same day. B. Covered, sealed, and heated to prevent freezing. Special Provisions: PRIOR TO INSPECTION REPORT APPROVAL: Property improvements (driveway, landscaping, etc) shall be verified to not have any 25% or greater slopes within 50 feet down gradient of the drainfield, and that the finish grades provide positive drainage away from the drainfield, i.e.; no ponding at or near the drainfield. Arl4- t ip Received By: / Date: 1 1 f - 0 S Issued By: / Date: 1( d S MUNICIPALITY OF ANCHORAGE :kms Community Development Department 46 of Phone: 907-- o ,•!4 Development Services Division Fax: to = - •®7.-, On-Site Water &Wastewater Program ti RUSH! ON-SITE SEWER/WELL PERMIT APPLICATION E Nov 0 6 Zu15 12- 3 017-101-58 '1 O Parcel I.D. << �� Property owner(s) Raptor Properties LLC Day phone a6 8 °� Mailing address 5725 Yukon Charlie Loop, Anchorage, AK 99502 Site address Raptors Knoll Circle Legal description (Sub'd., Block & Lot) Raptors Knoll, Lot 1 Legal description (Township, Range & Section) Lot Size 44,3174 Sq. Ft. Number of Bedrooms 4 APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (®all that apply) Absorption Field ❑X Initial ❑X Single Family (SF) ❑x (w/wo ADU) Septic Tank ❑X Upgrade ❑ Duplex (D) ❑ Holding Tank ❑ Renewal ❑ Multiple Dwellings ❑ Privy ❑ (SF and/or d) Private Well Water Storage ❑ THIS APPLICATION INCLUDES A VARIANCE /WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Ia5t1.4° _ Permit/Rush Fees:JM/t a Si Waiver Fees: Date of Payment: /l /1///S Date of Payment: Receipt Number: tOV Receipt Number: Permit No. OSPI S 13V.- Waiver No. Permit App_j-:• ::...c co Pannone Engineering Services ac Steven R. Pannone, Principal Registered Professional Engineer E-mail:steveCa)panengak.com July 31, 2018 Subject: Raptor's Knoll, Lot 1 Septic System Install Permit Request Design Narrative This is a design narrative for a permit to install a septic system to be issued for this property. The proposed systems will serve a proposed three bedroom (3) bedroom house. Currently the lot is undeveloped. The well on this lot has been drilled per the original permit, but moved downhill to accommodate the recently permitted drain field on the adjoining lot. This lot and the surrounding lots are served by private wells. Required separation distances to wells will be maintained. 1. Soils. One test hole was performed on this lot by Michael E. Anderson in February of 2013, and groundwater was monitored for at least seven days. Ground water was not observed to a depth of 18.5' below the surface in the test hole monitor tube after the 7 day monitoring period. Bedrock was not encountered in the test hole. Based on the results of the percolation tests and overall soils appearance; an application rate of 0.6 gallons/day/square feet was used for a conventional wastewater system in the area of the test hole. Due to the drain field that was permitted in the well radius of the permitted well on this lot, the proposed well was relocated and drilled west of the original proposed location, making it necessary to move the drain-field partially out of the test hole radius. Existing soils reports from the surrounding lots are attached to demonstrate the continuity of soils in the area, per 15.65.210.0 `Exception'. 2. Soil Absorption System Design. a. See Sheet 1 of the design package. 3. Surface Water:There is no surface water within 100 feet of the proposed septic tank and drain field. The proposed drain field upgrade will maintain at least 100 feet from all surface water and drainage ditches. 4. Topography: The existing topography generally slopes from the east to the west in the area surrounding the septic system at approximately 20%, flattening out to about 10% below the system. There are no steep slopes within 50' of the proposed drain field. The proposed drain field will maintain 50' separation all steep slopes. 5. Drawing Markings:The Drawings are marked "For MoA Review Only". When written notification that the review is complete and that there are no further comments is received from MoA On-Site Department, the note will be removed and "Issued for Construction" drawings will be issued. The proposed installation will not affect the future development of this or the surrounding lots Mailing: P.O. Box 100217, Anchorage, AK 99510-0217 Physical: 332 East Manor, Anchorage, AK 99501 Telephone: (907) 272-8218 FAX: (907) 272-8211 * SITE NOTES: CO I 1. DRIVEWAY LOCATION SHOWN IS FROM DEVELOPER'S PLOT PLAN. PES DID NOT DESIGN DRIVEWAY AND IS NOT RESPONSIBLE FOR IT'S LOCATION. THE DRIVEWAY WILL BE CONSTRUCTED ABOVE ORIGINAL GRADE AND WILL NOT CREATE ANY CUT SLOPES ON THE LOT, ABOVE OR BELOW THE SEPTIC SYSTEM. 2. RETENTION BASIN IS REQUIRED BY PLAT. THE BASIN WILL BE NO MORE THAN 2 FEET DEEP. THIS LOT IS TYPIFIED BY DRY WOODLAND VEGETATION, WITH WELL PERCOLATING SOIL. IT IS NOT LIKELY THAT THIS RETENTION BASIN WILL EVER CONTAIN WATER. 3. ANY SLOPE WITHIN 50' OF THE DRAINFIELD WILL BE AT 4:1 OR FLATTER. o Z WELL (E) •IP i w a I o \. \41-----....W-R���j _ \.,....,.. I p - J DRAIN FIELD (P,A1 �� ° o10• LF x 2.5'W x 10.0'ED x 12.5 TD v ac WITH CO AND MT AT EACH END r I 0 *ENSURE DRIVEWAY IS GRADED / SEPTIC AREA (E) o D'0 PREVENT RUNOFF FROM BEING RESERVE DRAIN FIELD (P) Y TRAPPED OVER DRAIN FIELD. 1OLF x 2.5'W x 10.0'ED x 12.5'TD o cn ix BASED ON CAT III C w z 10 a b �SE/Nwf ` M-M_M\ z iit. 41 1 • 1 aftimm,„„,„„... r 10008 SEPTIC TANK (P) n. WITH DOUBLE CLEAN OUT w a . it N 11 OVAND FOUNDATION CLEAN OUT w c.) 3 BR d APPROXIMATE LOCATION OFI-IJJ RETENTION BASIN. SEE NOTE 2. HOUSE(P) LOT 1 3o• v ct >o I NEW WELL _, . 1 _ Zi • -JW /MSM--170 o • /� - - c /1 10' UTILITY EASEMENT \ 142ND AVENUE N \ 12 / w I WELL (E) NOTES: �.......Nu, Dote CHANGE ORDER PANNONE ENG SVC, LLC �— OF AL l Dote 018 P.O. BOX 100217 ANCHORAGE, A99510 '��••''••.1044 PHONE (907) 272-8218 FAX (907) 272-8211 //*0).• * ��� •�y+�i Scale 50 \ \ * /, P.I.D. NO RAPTOR'S KNOLL, LOT 1 ar. `!., 017-101-58 RAPTOR PROPERTIES LLC Steven '1annorae P PERMIT NO. 0 fes•. CE 8149 ,• Al , OSPxxxxxx RAPTOR'S KNOLL CIRCLE �t mss'•• •\ PLAN ANCHORAGE, AK 99516 4�l���oFESS1gNP`� Sheet 2 'k\X -�� SPECIAL PROVISIONS TO SPECIFICATIONS GOA( 1. ALL CONSTRUCTION SHALL BE INSTALLED AS SPECIFIED IN THE MOST CURRENT EDITION OF THE MUNICIPALITY OF ANCHORAGE STANDARD SPECIFICATIONS (MASS) FOR COMPONENT PARTS AND MATERIALS USED IN CONSTRUCTION OF ON—SITE WASTEWATER DISPOSAL SYSTEMS AND AND IN ACCORDANCE WITH AMC 15.65. 2. SCOPE OF WORK: INSTALL NEW 1000g SEPTIC TANK, AND SOIL ABSORPTION SYSTEM. 3. GROUNDWATER WAS NOT ENCOUNTERED TO A DEPTH OF 18.5 FEET BELOW EXISTING GRADE AS EVIDENCED BY THE SOIL TEST HOLE. IF AN APPARENT WATER TABLE IS OBSERVED IN ANY OF THE EXCAVATIONS LESS THAN 18.5 FEET BELOW EXISTING GRADE NOTIFY THE ENGINEER IMMEDIATLY. APPROXIMATE FINISHED GRADE BY OTHERS PROVIDE FILL TO CREATE A MINIMUM OF 3.0'OF COVER OR INSTALL RIGID INSULATION FILTER FABRIC 4"0 DRAIN PIPE DRIVEWAY DRAIN ROCK 6"ABOVE PIPE INV HOUSE BY OTHERS BY OTHERS TH-2 (ANDERSON 2013) 2.5 OG -1.0 OL -2.0 DRAIN ROCK 7; 10'0 cv LEGEND W- WATER LINE/ WELL RADIUS 6.0 -15.0 SS NEW SEPTIC GM -18.5 ABBREVIATIONS CU COPPER DIP DUCTILE IRON PIPE TH TEST HOLE DESIGN PARAMETERS DESIGN PARAMETERS FC FOUNDATION CLEAN OUT T# TANK CLEAN OUT NO. PRIMARY SEPTIC SYSTEM RESERVE SEPTIC SYSTEM NO. BEDROOM: 3 (450 gpd) NO. BEDROOM: 3 (450 gpd) C# CLEAN OUT NO. TANK SIZE: 1000 TANK SIZE: 1500 ADVANTEX M# MONITOR TUBE NO. PERC RATE: 17 MPI W/ AX20 POD R.I. RIGID INSULATION SOIL RATING: 0.6 GPD/SF PERC RATE: 17 MPI DCO DOUBLE CLEAN OUT AREA RQD: 750 SF SOIL RATING: 4 GPD/SF DV DIVERTER VALVE SYS. TYPE: DEEP TRENCH 10.0'ED AREA RQD: 112.5 SF FS FLOW SPLITTER MIN LENGTH: 37.5 LF SYS. TYPE: DEEP TRENCH 10.0'ED BFG BELOW FINISH GRADE MIN LENGTH: 5.6 LF OG ORIGINAL GRADE USE: FG FINISH GRADE 40 LFx2.5'Wx10.0' E.D., 12.5' TD USE: FF FINISH FLOOR TOTAL AREA: 1,000 SF 10 LFx2.5'Wx 10.0' E.D., 12.5' TD TS&V TOPSOIL AND VEGETATE TOTAL AREA: 200 SF NIC NOT IN CONTRACT NOTES: ��� \\ Dote PANNONE ENG SVC, LLC - OF A���l CHANGE ORDER P.O. BOX 100217 ANCHORAGE, 6/27/2018 99510 ?�� qs ll PHONE (907) 272-8218 FAX (907) A.272-8211 4, ••... Scale j*' 4 .twv. �..I�j P.I. TS 4titRAPTOR'S KNOLL, LOT 1 017-101-58 RAPTOR PROPERTIES LLC r Steven R. Pannone / PERMIT NO. RAPTOR'S KNOLL CIRCLE Mas . CE 8149 \�/ osPxxxxxx DESIGN DETAILS ANCHORAGE, AK 99516 <<iirr. ••o�sso•• Sheet2 2 •\\x, COPY or; ;,-,„,,I s(,tbd . -P le ,,,,,,,,,, Municipality of Anchorage �RsoF � Sd0� Development Services Department NO Cse ,: '•;1 • Building Safety Division o* : 49TH Ofp . /1 c.-Ak...e On-Site Water and Wastewater Program 0 6 4700 Elmore Road 0/r`` _, r P.O. _ V •M CHAEL E. ANDERSON, ' : a' ��► . .Box 196650 Anchorage,AK 99507 www.ci.anchoraoe.ak.ug �,•. S (907)343 7904 �A iii,!. G -4 8i ••• N��� Soils Log - Percolation Test ,6I�d� veO ' Performed For: Ray Hickel Date Performed: Feb 8,2013 Legal Description: Timber Trail Subdivision, Lot 1 Township,Range,Section: Slope Site Plan 4,11/ Depth 1:1 (Feet) 0 & 1- 10�- l ryt1� 2-r o � It 4- 6.0 ,.._.:44 K IVO 6- �� � ;rL 7- 8- WAS GROUND WATER 9- ENCOUNTERED? S 10- • IF YES,AT WHAT DEPTH? L - Depth to Water After 0 11- Monitoring? Cw„4„r P E 12- Date: -I>-i S 13- 14- Reading Date Gross Time Net Time Depth to Water Net Drop 15-c_ _ s 1 2/14/2013 I' 1 /..'/..' J,Ej " 7 16- 17 .a 2 10121 ;C, MI6 I,2c ' 1 ,(y °1 18- 4 (o;L d .30 Vat 1 , (1," 11 �� h 19:- —ft?,S" 5 I C' 91 '' - 0 `%7. ....-,,- 20- 6 If ;Z s 3 o I,,I rf s K.,&) (, ,,1" PERCOLATION RATE (7 (minutes/inch) PERC HOLE DIAMETER -I'd TEST RUN BETWEEN 4--„c FT AND f..:(::, FT COMMENTS Pero Cavity was presoaked PERFORMED BY: A. Harala 1114E/�V, ,I) Ca .,.<Q...-.-e RTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: iii (7-/)e .V 141.3 • of • �^ Municipality of Anchorage / On-Site Water and Wastewater Program —/ (907)343-7904 SA ETV Certificate of On-Site Systems Approval Parcel I.D. 017-101-58 Expiration Date: it\ 1`I .a 0 1. GENERAL INFORMATION Complete legal description RAPTOR KNOLL L1 Location (site address) 14175 RAPTORS KNOLL CIR. Current Property owner(s) SPINELL HOMES INC. Day phone Mailing address 1900 W. NORTHERN LIGHTS BLVD Real Estate Agent Day phone 2. TYPE OF DWELLING: Single Family(w/wo ADU) ❑ Duplex El Multiple Dwellings(Single Family and/or Duplex) 3. NUMBER OF BEDROOMS: 3 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well Q Individual Individual Water Storage ❑ Holding Tank ❑ Community Class Well ❑ Community ❑ Public Water System ❑ Public Sewer ❑ WaiverNariance request for: Distance: Received by: Date: /7--//9, COSA to be released engineer,unless otherwise requested by the engineer. COSA Fee $ 6.(1.0 Waiver Fee $ Date of Payment 14/0 Date of Payment Receipt Number l)r-1(40:J .7 Receipt Number COSA# 0Ca/403y Waiver# 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation,based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is(are)safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are)in compliance with all applicable Municipal and State codes,ordinances,and regulations in effect at the time of installation. In conducting an adequacy test,I attempt to provide a thorough,conscientious engineering analysis of the system in accordance with MoA COSA guidelines and regulations.The reported results describe the performance of the system under the conditions encountered at the time of the test, and separation distances measured to readily identifiable features. The operational life of all wells and septic systems depend on the local soil condition,ground water levels that may fluctuate during the year,and the water usage of the family being served by the system.These conditions are outside the control of the evaluator of this system. All systems eventually fail and satisfactory test results do not guarantee future performance of the system,nor do they guarantee that there are no hidden defects or encroachments.Therefore we cannot provide any warranty for future performance, nor can we estimate remaining life of the system.The content of this report is for the sole benefit of the owner listed above. Name of Firm Pannone Engineering Services LLC Phone (907) 745-8200 Address P.O. Box 1807 Palmer, AK 99645 Engineer's Printed Name Steven R Pannone .4a , Date `e/24 *' ,'• ,\ y*ft 6. DSD SIGNATURE "' �i ""' .1 ter System#1 Approved for 3 bedrooms �j SIeveri 1t. Pannone• le `ti#� . CE-8149 System #2 Approved for bedrooms titkDisapproved er�OFESSI� '+ Conditional approval for bedrooms, with the following stipulations: ON-SITE �, WATER AND ` PrI WASTEWATER oz r PROGRAM ' Z ' QGP\l\cs- By: e.0.0 CQL ) et. Ti>M Ecklurt3 Original Certificate Date: De C 1 9, .20(1S The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On-Site Systems Approval (COSA)based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: COSA Checklist X Nitrate Advisory Septic System Advisory Arsenic Advisory Well Flow Advisory Other COSA blue sheet_f . If more than 1 septic system is on the lot: COSA Checklist# 1 of 1 Structure served by this system 1 Certificate of On-Site Systems Approval Checklist Legal Description: Raptors Knoll L1 Parcel ID:017-101-58 A. WELL DATA Well type Private If A, B, or C provide PWSID# Well Log (Y/N) Y Date completed 7/9/18 Sanitary seal (Y/N) Y Wires properly protected(Y/N) Y "+ Total depth 340 ft. Cased to 55 ft. Casing height(above ground) in. FROM WELL LOG AT INSPECTION Date of test 7/9/18 Static water level 148 ft. ft. Well production 4.5 g.p.m. g.p.m. WATER SAMPLE RESULTS: 4.23 Coliform NEG colonies/100 mL Nitrate v mg/L Arsenic N/" ug/L Date of sample: 12/10/18 Collected by: PES NP B. SEPTIC/HOLDING TANK DATA Tank Type/Material Septic/Plastic Date installed 10/18/18 Tank size 1000 gal. Number of Compartments 2 Cleanouts(Y/N) Y Foundation cleanout(Y/N) Y Depression over tank(Y/N) N High water alarm (Y/N) N/A Date of pumping New Pumper C. ABSORPTION FIELD DATA Date installed 10/19/18 Soil rating (g.p.d./ft2 or ft2/bdrm) 0.6 System type Deep trench Length 40 ft. Width 2.5 ft. Gravel below pipe 10 ft. Total depth 12.5 ft. Eff. absorption area 800 ft2 Monitoring tube Y Depression over field N Date of adequacy test New Results(Pass/Fail) For bedrooms Fluid depth in absorption field before test in. Water added gal. New depth in. Elapsed Time: min. Final fluid depth in. Absorption rate >= g.p.d. Any rejuvenation treatment(past 12 mo.)(Y/N&type) If yes, give date D. LIFT STATION Date installed Size in gallons Manhole/Access(Y/N) "Pump on" level at in. "Pump off level at in. High water alarm level at in. Datum Cycles tested Meets alarm&circuit requirements? E. SEPARATION DISTANCES WELL ON LOT TO: Septic tank/lift station on lot 100+ On adjacent lots 1001+ Absorption field on lot 1 00+ On adjacent lots 1001+ Public sewer main 75'+ Public sewer manhole/cleanout 1001+ Sewer/septic service line 25'+ Holding tank 1001+ Animal containment areas 501+ Manure/animal excrete storage areas 100 + SEPTIC/HOLDING TANK ON LOT TO: Building foundation 101+ Property line 101+ Absorption field 101+ Water main 25 + Water service line 25'+ Surface water + Wells on adjacent lots 1001+ ABSORPTION FIELD ON LOT TO: Property line 101+ Building foundation 1��+ Water main 101+ Water Service line 25'+ Surface water 1001+ Driveway,parking/vehicle storage 1 0'+ Curtain drain 501+ Wells on adjacent lots 100 + F. COMMENTS G. ENGINEER'S CERTIFICATION SOF Acr4,k ;zee • 91-14 I certify that 1 have determined through field inspections and ,,i . review of Municipal records that the above systems are in O*•49 N 1\ *t�$ conformance with MOA COSA guidelines in effect on this date. 0••• •• 0 Engineer's Printed Name Steven Pannone i••:Seven 12. Parinone• ` • rh 1, CE-8149 • / Date `4'lZ/,2 4} 4 ' v• '' ik1 ;oFEsso 4 l COSA canary sheet_2-6-15.doc