Loading...
HomeMy WebLinkAboutT12N R3W SEC 15 LT 57TI 2N R3W c 15 Lot 57 #015-052-28 ().. ..Nit, ---"--.1) . Municipality of Anchorage Community Development Department Page 1 of 3 On-Site Water&Wastewater Program 4700 Elmore St. •P.O. Box 196650 Anchorage,AK 99519-6650•http://www.muni.org/onsite •(907)343-7904 ON-SITE WASTEWATER INSPECTION REPORT Permit Number: OSP161301 PID Number: 015-05-228 • New 0 Upgrade Name: JOHN ESTABROOK ABSORPTION FIELD Address: • Deep Trench 0 Shallow Trench 0 Bed 0 Mound 9501 ELMORE ROAD*ANCHORAGE,AK 0 Other Phone: No.of Bedrooms: Sod Rating: Total Depth from original grade: (907) 277-6655 3 0.6 GPasq.Ft. 10 (MAX) Ft. LEGAL DESCRIPTION Depth to pipe invert from original grade: Gravel depth beneath pipe: SEE DWG. Ft. 7.05 Ft Subdivision: Block: Lot: Fill added above original grade: Gravel length: 57 SEE DWG. Ft. 55 Ft. I ownsnlp: T 12N Range: R3W Seaton: 15 Gravel width: Beds Number of Ones: Distance between lines: 2.5Ft. - Ft. SEPARATIONDISTANCES Total absorption area Number of trenches: Dist.between trenches: To Septic Absorption Lift Holding Public/Private From Tank Field Station Tank Sewer Lines 770+ SQ.Ft. 1 - Ft Well 100'+ 100'+ - - 25'+ TANK • Septic 0 S.T.E.P. ❑Holding 0 Other . Manufacturer Capacity: Surface Water 100'+ 100'+ - - ANCHORAGE TANK 1000 Gal. Material: i Number of compartments: Lot Line 5'+ 10'+ - - N/A . STEEL 2 Foundation 10'+ 10'+ LIFT STATION Curtain Drain Manufacturer. - NONE KNOWN Gal. "Pump or level at: 'Pump or level at: High water alarm at: Remarks: Pump Make&Moder Electrical Inspections performed by: PIPE MATERIAL House to tank F628 Tank to D3034 drainfield Installer RED DOG MASONRY Drainfield D3034 CO/MT D3034 Inspector GEG, Ltd. BENCH MARK (Assumed elevation) 102.78 Ft. Inspection Location and Description' 1st 11/22/2016 2nd 11/22/2016 3rd 11/23/2016 4th - BOTTOM OF TRIM AT FCO ENGINEER'S SEAL Community Development Department Approval _oo� ..\� oo�c.�F..Ai'� 3 Conditional approval: Date: ,%" ( :• , •..1-vo tr ..7.04, Gar -ss." po E-7 ' o Ve .. $i.l. .14•�� A�o Approved: VQ Qb )'..9 Date: Oilig �o�e pr1 °, o LICENSE EE � o s0�oCC 400�oo Inspection Report_1-1-12.doc ID c PERMIT OSP161301 RECORD DRAWING PARCEL NUMBER: 015-052-28 -- ( I IAI 1.11 5X. O, � \J / `V / J V� 4- .,& / A B C o / FCO 24.7 7.8 39.7 v / ST1 26.4 18.5 48.8 U / ST2 28.7 23.6 53.1 / DBL1 29.6 25.3 54.7 ce \ DBL2 30.8 27.0 56.0 z \ CO1 29.6 44.5 75.7 I.: \ / MT1 _ 29.6 41.0 71.8 N / CO2 _ 66.5 44.6 53.2 N / T12N,R3W,SEC15,LOT 56 MT2 62.6 42.5 54.2 \ / N / / — -- LOCATION OF SEPTIC SYSTEM SERVING KOREAN i--- _ METHODIST CHURCH(EAST&NORTHEAST OF SUBJECT -/ LOT)IS UNKNOWN.SEE ATTACHED DRAINING ADE j- N N APPROXIMATE / \ Q DRIVEWAY LOCATION // \ Q / OU) IX / H / O J Z W CO1r A / H W DBL1& z w p 11 MT1 DBL2 w Q U Ohry is / co J W C � � I w C FCO B I 0 1- ce ce 0 z J TH#5 I I W r W NEW 1000 c..10 ac GALLON STEEL '- SEPTIC TANK i 100 WELL RPpWS I C co MT2 a CO2 RESERVE SITE 11 NEW WELL LOCATION NOT PROPOSED BY NEW TRENCH GARNESS ENGINEERING GROUP,LTD.OR APPROVED BY MOA ONSITE DEPARTMENT \ \ I r \ \ Oa \ o°i N. VO N. ��m .E111 T12N,R3W,SEC15,LOT 64A N SCALE: / 3 F ° \�� 1�-40 //il / z \ I/ N m F ,4V__ .',", II1.44 ,4. GARNESS ENGINEERING GROUP, Ltd . : .. p •. --- ,,- -_-, ENGINEERING o SALFS.CONSULTING 3701 E TUDOR ROAD.SUITE 101'ANCHORAGE.AK 99507•PHONE(907)3374179'FAX(907)3343246•WEBSITE www pamesurpneem9.com ;. • • • • 0 PREPARED FOR: PHONE NUMBER: PAGE NUMBER: ♦ ,1 e A.Garness •;: JOHN ESTABROOK 277-6655 2 OF 3 • *- • C - LEGAL DESCRIPTION: DRAWN BY: �.• (•• T12N, R3W, SECTION 15, LOT 57 L.K.B. •j .. -1/6 6 .1.9'•••• cam. TYPE OF WORK: DATE: LICENSE•4 ESS`" 4•• RECORD DRAWING 7/6/2018 #AECC884 �%%IL%%' ' I r PERMIT NUMBER: PARCEL ID NUMBER: OSP161301 ' RECORD DRAWING 015-052-28 FINAL GRADE=101.3-101.7 TOP OF TANK ScT1 ST2 AT INLET=97.14 \_____ " TOP OF TANK AT OUTLET=97.10 INVERT OF BUNG NEW 1000 GALLON AT INLET=96.48 SEPTIC TANK INVERT OF BUNG AT OUTLET=96.24 U V TH#5 MT CO FINAL GRADE=100.3-100.5 ORIGINAL GRADE @ HIGHEST POINT=98.90 FILTER FABRIC • 0,„ .,•: .... .............., 1 NI i Ns ' INVERT OF PIPE=95.95 N. 7.05 FEET N, ys.,,'7,, i i i "N ti� $ BOTTOM OF TRENCH=88.90 RELATIVE ELEVATION @ BOTTOM OF T.H.=82.40 (T.H. DRY ON 11/22/2016) 4 or °4 q44Ab GARNESS ENGINEERING GROUP, Ltd *-� 4'i • '. • ENGINEERING,SAI FS. CONSULTING - .;,-- -,.-.7,-. 0 3701 E.TUDOR ROAD,SUITE 101'ANCHORAGE,AK 99507'PHONE(907)337-6179'FAX(907)338-3246'WEBSITE:www.gamessengineenng com PREPARED FOR: PHONE NUMBER: PAGE NUMBER: /0.�••, : I.' A. Garn.ss 44= JOHN ESTABROOK 907-277-6655 3 OF 3 •.%r',, C �� PROJECT/LEGAL DESCRIPTION: •DRAWN BY: I.4••••,1 iv 1�•••.•* T12N R3W SECTION 15 LOT 57 D.J.G. 1�,0 •. ••••.; P��• � TYPE OF WORK: DATE: LICENSE ,If%%"` 44 SEPTIC SYSTEM PROFILE RECORD DRAWING 7/2/2018 #AECC884 M-W Drilling, Inc. •P.O. Box 110389•Anchorage, AK 99511 •907-345-4000 • 907-345-3287 Fax• Job No.17-115 GROUNDWATER WELL LOG Well Owner. John&Geraldine Estabrook Use of Well: Domestic Legal Description: T12N R3W Sec 15 Lot 57 9501 Elmore Road,Anchorage AK CONSTRUCTION Drill Method: Air Rotary Hole Size: 6" Hole Depth: 200' Casing Size: 6" Cased to: 199.77' Material: A53B Wall: .250 Well Completion: Open end X Screen Perforated Method: Screen/Perforation description: Grout Notes: (3)Sack(s) of Bentonite Well Development Air surge Well Disinfected: Y/N Method: Yield test at 10 GPM for 1 hour(s)with 11.3' of drawdown(DD)from static level(SWL). Method: Submersible pump Static Water Level(SWL): 146.8' Start Date: 6/19/2017 Completion Date: 6/22/2017 Test Pump Date: 6/22/2017 Final Pump Install Date: WELL LOG Depth in feet from top Details of formations penetrated,size of material,color and miscellaneous details. of rasing. 0 TO 3 Casing Stick Up _ 3 TO 17 Gravel:brown, medium, dry 17 TO 110 Gravel:grey to brown, sandy,silty, dry 110 TO 120 Gravel:grey to brown, sandy, silty, damp 120 TO 125 Water gravel: medium, 1-2 gpm 125 TO 194 Gravel:sandy,silty,grey to brown 194 TO 200 Water gravel: medium to coarse, 10 gpm TO TO TO TO TO WAYNE E. WESTBERG TO --President,M-W Drilling,fit. -----AWACedifiv Mactwr t rrvnnr:am rArsztl r TO Ak Gen Conti Lk No 1000 TO TO WATER Q ITY TESTING � Coliform e Cs1/100mL Nitrates l • g 7 mg/l. Arsenic NIP ug/L MUNICIPALITY OF ANCHORAGE Development Services Department ` - ) Phone: 907-343-7904 On-Site Water & Wastewater Section ,\ Fax: 907-343-7997 Pump Installation Log Well Drilling Permit Number: OSP151264 Date of Issue: 8 - 14 _15 Parcel Identification Number: O\5 -051 _ I% Legal Description Block Lot Property Owner Name& Address: T12N, R3W, Sec 15 57 Estabrook, John Sr. 9501 Elmore Rd PO Box 100883, Anchorage AK 99510 Pump Installation Date: 7 -11 -2017 Pump Intake Depth Below Top of Well Casing: 195 feet Pump Manufacturer's Name: Goulds Pump Model: 10H507 Pump Size: 3/4 hp Pitless Adapter Burial Depth: 15 feet Pitless Adapter Manufacturer's Name: Martinson Pitless Adapter Installer: MVV Drilling, Inc. Well Disinfected Upon Completion? a Yes ❑ No Method of Disinfection: circulate chlorine solution through system and let sit overnight Comments: circulate chlorine solution through system and let sit overnight - water clean Pump Installer Name: Walter John Company: MW Drilling, Inc. Mailing Address: PO Box 110389 City: Anchorage State: AK Zip: 99511 Attention: The pump installer shall provide a pump installation log to On-site within 30 days of pump installation. On-Site Water & Wastewater System Permit ,1r • - View MUNICIPALITY OF ANCHORAGE , ., • It law Development Services Department n, ef On-Site Water & Wastewater Program " °' 1) 4700 Elmore Road, PO Box 196650 a l Department Anchorage, AK 99519-6650 Telephone: (907) 343-7904 Permit Number: OSP161301 am It ant Tax Code Number: 01505228000 Ill 12/ id I(c Work Type: WellSeptic Initial Permit Effective Dates: October 10, 2016 to October 10, 2017 Design Engineer: GARNESS ENGINEERING GROUP LTD Subdivision: T12N R3W SEC 15 Site Legal Address: T12N R3W SEC 15 LT 57 G:2436 Owner/Address: ESTABROOK JOHN J SR & GERALDINE T PO BOX 100883 ANCHORAGE AK 995100883 Site Mailing Address: 9501 ELMORE RD, Anchorage Lot Size in Sq Ft: 46228 Total Bedrooms: 3 This permit is for the construction of: Y Disposal Field Y Septic Tank N Holding Tank N Privy Y Private Well N Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80). 3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either: A. Open and Close on the same day. B. Covered, sealed, and heated to prevent freezing. Co *7 /0/0A Mat-et' 5 y2l1C- /o Ga-hon. an r), u c I i . Received By: �� / Date: Issued By: / / (/t/ ,,,z Date: /0/ MUNICIPALITY OF ANCHORAGE OCT 7 2015 v Community Development Department \ 1- Phone: 907s343;79g4t, - ` Development Services \ Fax: 907- 343-7997 On-Site Water & Wastewater Program Mayor Dan Sullivan On-Site Sewer/Well Permit Application For A Single Family Dwelling Parcel I.D. o 5- 05 a' 01$ Property owner(s) JOHN ESTABROOK Day phone 277-6655 Mailing address NHN ELMORE ROAD 'ANCHORAGE, AK Site address NHN ELMORE ROAD *ANCHORAGE, AK Legal description (Sub'd, Block& Lot ) T12N, R3W, SEC15, LOT 57 Legal description (Township, Section & Range) Lot Size Sq.Ft. Number of Bedrooms 3 APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DEWELLING: Gall that apply) Initial ® Single Family (SF) Absorption Field ® (w/wo ADU) ❑ Septic Tank ® Upgrade Duplex (D) ❑ Renewal ❑ Holding Tank ❑ Multiple Dwellings ❑ Privy ❑ (SF and/or D) Private Well Water Storage ❑ THIS APPLICATION INCLUDES A VARIANCE/WAIVER REQUEST FOR: N/A Distance: - I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal codes. GARNESS ENGINEERING GROUP, Ltd. (Signature of property owner or authorized agent) Permit/Rush Fees: 7< /92'1 Waiver Fees: Date of Payment: /'Ye neaJa) Date of Payment: Receipt Number: Receipt Number: Permit No. 05011/2°13°1' Waiver No. (Rev. 01/11) On-Site Water & Wastewater System Permit nocnt. co Sr q T' MUNICIPALITY OF ANCHORAGE c 4 i a, n In Development Services Department - On-Site Water &Wastewater Program 4700 Elmore Road, PO Box 196650 lleparemen[' Anchorage, AK 99519-6650 Telephone: (907) 343-7904 Permit Number: OSP151264 Tax Code Number: 01505228000 Work Type: WellSeptic Initial Permit Effective Dates: August 14, 2015 to August 13, 2016 Design Engineer: GARNESS ENGINEERING GROUP LTD Subdivision: T12N R3W SEC 15 Site Legal Address: T12N R3W SEC 15 LT 57 G:2436 Owner/Address: ESTABROOK JOHN J SR & GERALDINE T PO BOX 100883 ANCHORAGE AK 995100883 Site Mailing Address: Lot Size in Sq Ft: 46228 Total Bedrooms: 3 This permit is for the construction of: Y Disposal Field Y Septic Tank N Holding Tank N Privy Y Private Well N Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80). 3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either: A. Open and Close on the same day. B. Covered, sealed, and heated to prevent freezing. Received By: Gv /' z �- Date / Issued By: !/ vv heti Date: Vefir MUNICIPALITY OF ANCHORAGE Community Development Department �\ I // Phone: 907-343-7904 Development Services / Fax: 907- 343-7997 On-Site Water & Wastewater Program Mayor Dan Sullivan On-Site Sewer/Well Permit Application For A Single Family Dwelling Parcel I.D. 016- 052 -Z$ Property owner(s) JOHN ESTABROOK Day phone 277-6655 Mailing address NHN ELMORE ROAD *ANCHORAGE, AK Site address NHN ELMORE ROAD *ANCHORAGE, AK Legal description (Sub'd, Block & Lot ) T12N, R3W, SEC 15, LOT 57 Legal description (Township, Section & Range) Lot Size Sq.Ft. Number of Bedrooms 3 APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DEWELLING: Gall that apply) Initial ® Single Family (SF) El Absorption Field N (w/wo ADU) Upgrade ❑ � Septic Tank ® /1 " g 7n 11 Duplex (D) ❑ Renewal Holding Tank ❑ 4 i 4•r� • dit;ple Dwellings ❑ Int�tl,•kCI'" Sr and/or D) Privy ❑ c., v Private Well N ; t\ \5 3 2,015 - �. Water Storage ❑ w `ya THIS APPLICATION INCLUDES A VARIANCE/WAIVER REQUES\1JOR:g Lc'� N/A _ Distance: - I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal codes. GARNESS ENGINEERING GROUP, Ltd. (Signature of property owner or authorized agent) 'w,_ / Permit/Rush Fees: 61. 'r21S - Waiver Fees: Date of Payment: A'')!I 40� Date of Payment: Receipt Number: cRfo Receipt Number: Permit No. 059)512(Oy Waiver No. (Rev. 01/11) _ _. -. tJ GARNESS ENGINEERING GROUP, Ltd Adv"nr`"""'" 5 ter' a CIVIL&ENVIRONMENTAL EN GI NE ER S tr^^vnamaa=exi==tarau Dealer" July 21, 2015 Municipality of Anchorage Development Service Department On-Site Water & Wastewater Program 4700 Elmore Road Anchorage, AK 99507 Ref: Proposed Initial Septic System for T12N, R3W, Sec 15, Lot 57 To whom it may concern: The referenced property is currently vacant and the owner is proposing to have a 3 bedroom house constructed and have it served by a private well and septic system. We are proposing to install a 1250 gallon S.T.E.P. tank and a deep trench type drainfield. Four (4) testholes were excavated on the property and the drainfield will be designed around the 30 foot radius of testhole #3. Comments regarding the design are summarized as follows: 1. SOILS: See the attached 2015 soil logs which show the soil classifications, groundwater monitoring, and the percolation test results. 2. DRAINFIELD DESIGN: See attached design drawing for drainfield specifications. 3. SURFACE WATERS: There are no surface water concerns. 4. TOPOGRAPHY: As can be seen on the attached topography drawing, the average topography around the proposed drainfield is 5% running southeast to northwest. We are unaware of any adverse impacts this installation would have on adjacent wells or septic systems. If you have any questions, please contect us at 337-6179. Thank you for your assistance. c- ely, See C0 *- 1 Jeffre., • . Gar`e-s, P.E., M.S. 9111') Presioent 3701 East Tudor Road, Suite 101 *Anchorage,Alaska 99507-1259 Phone: (907)337-6179*Fax: (907) 338-3246*Website: www.garnessengineering.com co #► / A : // LII . I . rSTn1 ii 1a7 II II '¢ - -\—�� �fl V N U \ \ q // tjtw T12(9, R3W, SL S, LOT 49E /64, /I \ I S E: / // LIVING STRUCTURE \ // — j I / ', _yam— 1' - 100' / / \ SHED i j / — %�j 1 //// I2 34 �L •p 6 • ,', ""',#/#I I T12y(R3W, SEC15, LOT 55 E\ \50 •�. °' rj/ I / \ No4E'NOC*$ 'S5 / N\� / es H\fB \ T12N(3W, SEC15 'CDT 56 / \\ CSE AC AR'-';) / Z / �\ / .o \ II-I / I N / :•Q \ T12N, R3W, SEC15, LOT 58 n/ I ' 0 �� / $- 1 lei - __ �i1 `THy1 TH#2 :: / 1 I 1 wELL otos W I 1� s B �1� /� _ - // �1; 1 20� C°'' SECTION SIXTEEN TRACT D I�r 1 SI° _—- ANCHORAGE HORSE COUNCIL IJ I THNS t .BI# \ /_aa� /(MOA) G r.:) \ NO CONCERNS I .:, ....� _../' ' �� I \ / J \ / i ' I I T12N,`R3W. LOT 63A 2 �//I / - - \ \` w \ \ 3 �/ r \ \ o \ 1 N N. o / I T12N, R3W, SEC15, LOT 64/. I 1 1 100' WELL RA IWU� I I L 6 H61 H 7�v e / ), \ / I \ I ` T� *cu. I \ I •a0ius / I \ 1 I 1 _'N.' . .4.- k sFi1„ .ase OF • 1,•� L. ...- s. t Illi"�� �J��• /�••• �. GARNESS ENGINEERING GROUP, Ltd I / 9 h \_* • CIVIL&ENVIRONMENTAL ENGINEERS I • 3701 E. TUKN ROAD, SUITE 101 •ANCHORAGE.624 99507 • PHONE(907) 337-6179 • EY(907)336-3246• NEBSITE: .ngomeisenr.e'.y.com ,, y� J1 • • PREPARED FOR: PHONE NUMBER: PAGE NUMBER: 0(r . rey A>QORtess i, JOHN ESTABROOK 277-6655 1 OF 2 •��'/Jl VCE-7953 14' LEGAL DESCRIPTION: DRAWN BY: •• F •• (� $• T12N, R3W, SEC15, LOT 57 D.J.G./PNB •• pFp'' 11z+�1�•' �4� TYPE OF WORK: DATE: •" IDI? FESS\('tet \ SEPTIC SYSTEM DESIGN UPGRADE 9/23/2016 ,-•------ . 1 • CO I / (DESIGN CRITERIA: / GEG, Ltd. HAS A e��j�j�cATiloN \ I NUMBER OF BEDROOMS: 3 LETTER THAT PERTAINS TO THIS DESIGN. NOTE: THE CONTRACTOR 450 TO OBTAIN A COPY OF THE LETTER SHALL HAVE THE WEST & GALLONS PER DAY (GPO): CONTACT GEG. BY PROCEEDING FORWARD SOUTH LOT LINES, AND ALL PERCOLATION RATE/S: 20 MIN/INCH WITH THIS INSTALLATION. THE ENGINEER. WELL RADII FLAGGED BY A PROPOSED APPLICATION RATE: 0.6 GPD/E7' WELL DRILLER, CONTRACTOR AND / MINIMUM DRAINFIELD SO.FT.: 750 FT' - PROPERTY OWNER AGREE THAT THEY REGISTERED LAND SURVEYOR - HAVE READ THESE SPECIFICATIONS AND PRIOR TO CONSTRUCTION. DRAINFIELD DESIGN: AGREE TO ACCEPT THE TERMS AND / CONDITIONS OUTLINED. MAXIMUM DEPTH OF EXCAVATION: 10 FT / ' WIDTH: 2.5 FEET/ / \ALTERNATE SITE DESIGN CRITERIA- LENGTH: 55 FEET Illi ldill / NUMBER OF BEDROOMS: 3 EFFECTIVE: 7 FEET GALLONS PER DAY (GPO): 450 -- — ACTUAL SO.FT.: 770 FT' / PERCOLATION RATE/S: 20 MIN/INCH ‘ z / PROPOSED APPLICATION RATE: 4.0 GPD/FT' \ /T12N, R3W. SEC15, LOT 56 / MINIMUM DRAINFIELD SO.FT.: 112.5 FT' N / N. / / ALTERNATE DRAINFIELD DESIGN: N / / 7 MAXIMUM DEPTH OF EXCAVATION: 10 FT / WIDTH: 2.5 FEET / - , LENGTH: 15 FEET -, _ — — — — — r/ ) 1 EFFECTIVE: 7 FEET / -. }11/ 'M1 / ACTUAL SO.FT.: 210 FT' / / REVUS 1 „ PROPOSED DRAINFIELD / WE1-(- / / O 100 ////i/////.� A PROPOSED 1000 GALLON /PROPO i SEPTIC TANK; INSTALL DOUBLE /. Y / / �•, •;;- CLEANOUTS AFTER TANK / / \ �� / 1 Nr.#4, INSTALL FCO U1 4 ' Z W / il /W w /-2.?,/„...--:* ! PROPOSED 3 W / BEDROOM ' /, / a HOUSE / / o cc F 1 :7 ALTERNATE SITE / cii LaT / • 4 /3q� 7 II ie____LI j...1,i, IY\ /1 I I) _____ ___________ SCALE: t ___aIiaoe 1\ .e /col:.....‘r,..••..•.k7ik.:...11...4.::II.:....sa O GARNESS ENGINEERING GROUP,• Ltd "(•QJ. • .„ ....... . . tiw --4 CIVIL&ENVIRONMENTAL ENGINEERS..•-- ----..----• .4 % I ' I 0 3701 E. TUDOR ROAD. SUITE 101 • .ANCHORAGE.A( 99507 • PHONE (907) 337-6179• Oa (907) 338-3246 •WEBSTE: ..�00rnessenglneerino,cem 0. ( / '''((( - 0 PREPARED FOR: PHONE NUMBER: PAGE' NUMBER: # :I elf ,y A. G ness = JOHN ESTABROOK 277-6655 2 OF 2 I cjtGE-\g 2A. LEGAL DESCRIPTION: DRAWN BY: �. 43 T12N, R3W, SEC15, LOT 57 PNB D.J.G. .•F 1°i611 •'* C, 4 / . -0..0PROF.... .. P� v� \,.. INITIAL WORK: DATE: SYSTEM DESIGN DAT1O/6/2O16 ,t0e�asao _�w 1 ss-****c.... 4I• GARNESS ENGINEERING GROUP, Ltd • I : •la ' '� t aNw sr ==== sar: 3S CIVIL&ENVIRONMENTAL ENGINEERS �ara� 0 3701E.TUDOR ROAD SUITE 101'ANCHORAGE,AK 99507'PHONE(007) 337-0179'FAY 190713303240'WEBSITE'.WON 9ameeen9Uneemp com •, • • SOIL LOG - PERCOLATION TEST �.o'; ffrey A.Gamess kJ LEGAL DESCRIPTION: T12N,R3W,SEC 15.LOT 57 .• TF•••,, "/}7/S • $5 PERFORMED FOR: JOHN ESTABROOK DATE: 5/23/14 •44. PROFESSO\N\Ptee DEPTH -- -- ORGANICS \ •1,,"„'•• (feet) •----- TEST HOLE #1 •• r • SOIL CLASSIFICATIONS l/ i• PVAN °voie`rz` 2 • • ; d':;or4 GW ORG • • a:` ' GP ML 3 r T12N,R3W„8EC15,LOT 56 • • GM J�,ICL - --- 4 — GC � 1/, OL • 1 G° D • 000cpoD SW MH a • • •I SM OH o TH#1 TH#2 6 ' . • •� SC o ■ • cz • TES• TAPPROXIMATEHOLE GONS 7 DEPTH TO ARE • • GROUNDWATER DATE N r 8 — r • GM DRY 5/23/14 • • DRY 5/30/14 -- ----_ _ SCALE: I •r 9 • I • • 10 — I I �: 1 • • DATE READING CLOCK NET TIME WATER LEVEL NET DROP 11 — • • TIME (MINUTES) READING (IN.) (INCHES) 12 — • • 5/30/14 1 3:19 - 6 • • 2 3:49 30 4.75 1.25 r 13 — • 3 3:49 - 6 • • 4 4:19 30 5 1 14 — 5 4:19 - 6 -• • • • 6 4:49 30 5 1 15 — • • • • 16 —, • • 17 — B.O.H. 18 — PERCOLATION RATE 30 (MIN /INCH) PERC. HOLE DIA. 6 (INCHES) 19 TEST RUN BETWEEN 5.0 FT. AND 6.0 FT. 20 A FOUR HOUR PRESOAK WAS PERFORMED: YES ❑NO SOILS LOGGED BY: ROB CAMPBELL PERCOLATION TEST PERFORMED BY: ROB CAMPBELL COMMENTS: PERCOLATION READINGS ARE WITHIN 1/16 OF INCH. PERFORMED BY GEG, Ltd. I,JEFFREY A. GARNESS, CERTIFY THAT THIS WAS PE�f2FOFjMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE: 7 37 !f J ••�E OF e♦♦♦♦ \ ' : 24 4 == ' ;_ _.- fly• GARNESS ENGINEERING GROUP, Ltd 4 „ 'N * • ��• -m.,,d- - CIVIL&ENVIRONMENTAL ENGINEERS°•*"' — ----- • „o,ETUDOR ROAD SUITE o' ANCHORAGE SOIL Le9597'OG -oNE(0071 337-6179'FAX 1507) 3384246'PERCOLATION TESTrEvimv eamBS�^o^e^na`am •:• • , j�•: 'ffreye. ess :co= ♦ -- F�•••• '-'J�a.1 .,,,_,H,,•-s .i PERFORMED FOR: JOHN ESTABROOK DATE: 5/23/14 ♦♦ ♦,P PROFESS .•• ♦ R • DEPTH — ORGANICS \ ♦,"",•• (teeU r • TEST HOLE #2 1 — • r • SOIL CLASSIFICATIONS O Pl�'AN 2 .. --- • •• ''a�' '.I°C. GP y ML T12N,R3W�8EC15,LOT 56 • GM �rcoLL --- –;4 _ 4,4/! GC• OOep pV• otto°o° SWMH < r • .•�.P�� SP CH + 5 — • • �I/' t SM ' OH o Hal TH#2 6 — • • SC J • • n TESTHOLE LOCATIONS 7 — DEPTH TO DATE ARE APPROXIMATE / ` • r GROUNDWATER N • 8 — • • GM DRY 5/23/14 • • DRY 5/30/141 "_-- SCALE' 9 — • • �; 71:21 _-�� 1^=1p ' • Y JJ �\ I 10 — • r 1 r • • • DATE READING NET TIME WATER LEVEL NET DROP 11 — • • TIME (MINUTES) READING (INCHES) • • . 5/30/14 1 3:10 - 6 12 — • • _ 2 3:40 30 3.5 2.5 • • - • 13 — 3 3:40 6 • 4 4:10 30 3.75 2.25 r • - 14 — • 5 4:10 - 6 - • • 6 4:40 30 3.75 2.25 15 — • r • 16 • 1 • __ • - 17 — B.O.H. 18 — I 1 PERCOLATION RATE 13.33 (MIN./INCH) PERC. HOLE DIA. 6 (INCHES) 19 — TEST RUN BETWEEN 5:0 FT. AND 6-0 FT. 20 A FOUR HOUR PRESOAK WAS PERFORMED: YES ❑ NO SOILS LOGGED BY: ROB CAMPBELL PERCOLATION TEST PERFORMED BY: ROB CAMPBELL COMMENTS: PERCOLATION READINGS ARE WITHIN 1/16 OF INCH. PERFORMED BY GEG, Ltd. I, JEFFREY A. GARNESS, CERTIFY THAT THIS WAS PE FOR ED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE: 7�J75 / r .sssassy1, - ( 4 .t. OF to. Q/ Or,rPm ',ii`, , 7aW' 1a I (° i KP 1 • i/ 4C).•' ,� � . >f. �U s>•*:�r ...,..:wu-�j ENGINEER j ,...�j �jx 44-'•"‘' . ' '•. GARNESS ENGINEERING GROUP, Ltd .44 . ' �� r. a::as:.on2 - _.rearm -A> CIVIL&ENVIRONMENTAL ENGINEERS i 3701 E.TUDOR RAD,OSUITE 101'ANCHORAGE.AK 99507'PHONE(907) 337-5179'FAX(907) 335-3246'WEBSITE'.*vex 9emeeve971111P0H111 ; / •`�y�y SOIL LOG - PERCOLATION TEST ��� :: `J eyA. mess dCu• ♦ C€-795� �2• LEGAL DESCRIPTION: T12N,R3W,SEC15,LOT 57 .•A �FD 7 ..11/•S Cf* PERFORMED FOR: JOHN ESTABROOK DATE: 6/17/2015 w1� E'ROFESS\urP••�' DEPTH — �1........• (feet) • ^^ TEST HOLE # 3 == ORG/LOAM 1 .^^�^ SOIL CLASSIFICATIONS SITE PLAN 2 — • • :;1fi;;:: GW _:_ ORG • r ,a< i+C GP ML : 1 : : { GM /< CL • • o°v o°p SWjjf)) MH 4 GCQ • • , SP CH ��� 5 — • • � • '•• SM i OH Q • • 5 SC G�� s N • • 7 — • DEPTH TO DATE P GROUNDWATER �". QIA . 8 • • DRY 6/17/2015 • • GM DRY 6/26/2015 SCALE: • 9 — • t'=too' r r 10 • r • • • DATE READING CLOCK NET TIME WATER LEVEL NET DROP 11 • r TIME (MINUTES) READING (INCHES) 12 — • • 6/18/2015 1 2:05 - 6.. - • • 2 2:35 30 31/2" 21/2" 13 — 3 3:05 r • - - " It • • 4 3:35 30 3 3/8" 2 5/8" • 14 — • • 5 3:35 - 6" - • • 6 4:05 30 3 3/8" 2 5/8" 15 — • r r r • r 7 B.O.H. 18 PERCOLATION RATE 1'(.411N./INCH) PERC. HOLE DIA. §INCHES) • 19 — TEST RUN BETWEEN 5T. AND FT. 6 20 A FOUR HOUR PRESOAK WAS PERFORMED YES •NO E SOILS LOGGED BY: DAVID GARNESS PERCOLATION TEST PERFORMED BY: ERIK WIDGER COMMENTS: PERCOLATION READINGS ARE WITHIN 1/16 OF INCH. PERFORMED BY GEG, Ltd. I, JEFFREY A.GARNESS,CERTIFY THAT THIS WAS PE ORM D IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE: 'i/J 7 Ic .1 I .t Cr \ri "i'4 '' P ir �Si ' ta' ((. . . a xV •� *. .. I ''7 ' fi )S4aR —. . 'GARNESS ENGINEERING Ltd ' • ` � • • • ..., -„. .:= . ,Y. ---- CIVIL&ENVIRONMENTAL ENGINEERS —"""'=4N ... / 0 3701E.TUDOR ROAD.SUITE 10I'ANCHORAGE,AK 99507'PHONE(907) 337-6179'FAX 1907) 3303249'WEBSITE'.Axe*9ameesen9ncenn4 corn • ; •. � t . SOIL LOG - PERCOLATION TEST •��:" • eYE�9 3ness :\_�= LEGAL DESCRIPTION: T12N,R3W,SEC15,LOT57 �♦S 37AST/4.. . PERFORMED FOR: JOHN ESTABROOK DATE: 6/17/2015 ••1�.PROFESS\°\Ar4 b DEPTH ,-__ ORG ........... (teed -.-27-.-27--=' _ TEST HOLE # 4 1 _ LOAM • SOIL CLASSIFICATIONS SITE PLAN 2 — • • • • t 1 i';r -, GP ML 3 — ' • GM �1 1` CL a • • j � GC OL �,P� * • ��4 00 °E SW I MH pon Q • • ••••F•sSP �/ CH �up� 5 • • }f v9°� SM OH 4 6 • • 9' q SC O� •• • '1\ 7 — • • DEPTH TO DATE P • GROUNDWATER c(0</� N 8 • • DRY 6/17/2015 • r • DRY 6/26/2015 SCALE: 9 — • 1••=100' • GM • 10 • • • DATE READING CLOCK NET TIME WATER LEVEL NET DROP 11 — • • TIME (MINUTES) READING (INCHES) 12 — • • 6/17/2015 1 2:00 6" — • • 2 2:30 30 3 3/8" 2 5/8" 13 — ' • 3 2:30 - 6" • - 4 3:00 30 3 3/8" 2 5/8" • • 14 — • 5 3:00 6" - r • 6 3:30 30 3 3/8" 2 5/8" 15 — r • • • 12 • r 17 — B.O.H. 18 I, PERCOLATION RATE 11(411N./INCH) PERO. HOLE DIA. §INCHES) 19 — TEST RUN BETWEEN 5.5T. AND FT. 6.5 20 A FOUR HOUR PRESOAK WAS PERFORMED: YES M0 ❑ SOILS LOGGED BY: DAVID GARNESS PERCOLATION TEST PERFORMED BY: ERIK WIDGER COMMENTS: PERCOLATION READINGS ARE WITHIN 1/16 OF INCH. PERFORMED BY GEG, Ltd. I,JEFFREY A. GARNESS, CERTIFY THAT THIS WAS PER5ORMD IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE: 7/01.1AC 2 • CO - I • f GARNESS ENGINEERING GROUP, Ltd i" • •• ' • •" I 1 CIVIL&ENVIRONMENTAL ENGINEERS.. - +f •• 3701 E.TUDOR ROAD,SUITE 101'ANCHORAGE,AN 99507'PHONE(907)337-5079'FAX(907)339'3216•AEBSITEww gamescenpineemp"DM 5evt • L . SOIL LOG - PERCOLATION TEST I� ray A. arness �� .•%•. CEY953 • =i LEGAL DESCRIPTION: T12N R3W SECTION 15 LOT 57 �••• I PERFORMED FOR: JOHN ESTABROOK DATE: 9/2/2016 ♦•••`Q•••oig...................• •0 ..OFESS DEPTH ---- \ ,��\�`���� (feet) ._--_ ORG/LOAM TEST HOLE #5 # A£Ce9 9't • , SOIL CLASSIFICATIONS SITE PLAN 2 — • - • a.,;t''0 GW ORG 3 • • IhIII9I GM // / CL • ■ %�' GC f OL _ 4 • • °°o°o o•. SW MH • ■ SP CH S' 5 • • I�ItI�IIi SM /' '/ , OH !`O5 6 — • • �4i s! SC C- ,,SQ. 7 — • • DEPTH TO DATE • ■ GROUNDWATER• ��iP N 8 — • • DRY 9/2/2016 • • DRY 9/20/2016 SCALE: • 11.100.9 — ■ • GM • • 10 — IN • • ■ DATE READING CLOCK NET TIME WATER LEVEL NET DROP 11 — • TIME (MINUTES) READING (INCHES) ■ • • 9/21/2016 1 2A0 - 6" 12 — • ■ 2 3:10 30 • • 13 — 3 3:10 • 6" • 4 3:40 30• • 14 — • 5 3:40 - 6" • • 6 4:10 30 15 — • 6 • • B.O.H. 17 — 18 PERCOLATION RATE 20 (MIN./INCH) PERC. HOLE DIA. 6 (INCHES) 19 — TEST RUN BETWEEN 5 FT. AND 6 FT. 20 A FOUR HOUR PRESOAK WAS PERFORMED: U YES ❑NO SOILS LOGGED BY: DAVID GARNESS PERCOLATION TEST PERFORMED BY: LANDON BRUCE COMMENTS: PERCOLATION READINGS ARE WITHIN 1/16 OF INCH. PERFORMED BY GEG, Ltd. I, JEFFREY A. GARNESS, CERTIFY THAT THIS WAS PERFQ9RME7O IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE: 9/ t 8/(L Permit Number: Tax Code Number: Work Type: On-Site Water & Wastewater System Permit OSP151264 01505228000 WellSeptic MUNICIPALITY OF ANCHORAGE Development Services Department On-Site Water & Wastewater Program 4700 EImore Road, PO Box 196650 Anchorage, AK 99519-6650 Telephone: (907) 343-7904 Initial Permit Effective Dates: August 14, 2015 to August 13, 2016 Design Engineer: GARNESS ENGINEERING GROUP LTD Subdivision: T12N R3W SEC 15 Site Legal Address: T12N R3W SEC 15 LT 57 G:2436 Owner/Address: ESTABROOK JOHN J SR & GERALDINE T PO BOX 100883 ANCHORAGE AK 995100883 Delmar ~m. ent Site Mailing Address: Lot Size in Sq Ft: 46228 Total Bedrooms: 3 This permit is for the construction of: Y Disposal Field Y Septic Tank N Holding Tank N Privy Y Private Well N Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80). 3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either: A. Open and Close on the same day. B. Covered, sealed, and heated to prevent freezing. MUNICIPALITY OF ANCHORAGE Community Development Department Development Services On-Site Water & Wastewater Program Phone: 907-343-7904 Fax: 907- 343-7997 Mayor Dan Sullivan On-Site SewerNVell Permit Application For A Single Family Dwelling Parcel I.D. O1~' o5~. -Z-~ Property owner(s) JOHN ESTABROOK Mailing address NHN ELMORE ROAD *ANCHORAGE, AK Site address NHN ELMORE ROAD *ANCHORAGE, AK Day phone 277-6655 Legal description (Sub'd, Block & Lot ) T12N, R3W, SEC15, LOT 57 Legal description (Township, Section & Range) Lot Size Sq. Ft. Number of Bedrooms APPLICATION IS FOR: APPLICATION IS AN: (~_11 that apply) Initial [] Single Family (SF) Absorption Field [] Upgrade [] (wlwo ADU) Septic Tank [] ~ ..c~Duplex (D) __ . Renewal J/'~-~--~--~ z~ Holding Tank I I ~/P'~_~~l!, pie Dwellings Privy [] and or Water Storage [] ~.. THIS APPLICATION INCLUDES A VARIANCE/WAIVER REQ~ N/A Distance: - TYPE OF DEWELLING: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal codes. GARNESS ENGINEERING GROUP, Ltd. (Signature of property owner or authorized agent) Permit/Rush Fees: ~"~q ~' "J"~"l~' '~ Waiver Fees: Receipt Number: Permit No. Cf'a~] ,~ ~.~'~ Date of Payment: Receipt Number: Waiver No. (Rev. 01/11) GARNESS ENGINEERING GROUP, Ltd ~'~ ~-~ ~ CIVIL & ENVIRONMENTAL ENGINEERS ~-,~;~ July 21, 2015 Municipality of Anchorage Development Service Department On-Site Water & Wastewater Program 4700 Elmore Road Anchorage, AK 99507 Ref: Proposed Initial Septic System for T12N, R3W, Sec 15, Lot 57 To whom it may concern: The referenced property is currently vacant and the owner is proposing to have a 3 bedroom house constructed and have it served by a private well and septic system. We are proposing to install a 1250 gallon S.T.E.P. tank and a deep trench type drainfield. Four (4) testholes were excavated on the property and the drainfield will be designed around the 30 foot radius of testhole #3. Comments regarding the design are summarized as follows: 1. SOILS: See the attached 2015 soil logs which show the soil classifications, groundwater monitoring, and the percolation test results. 2. DRAINFIELD DESIGN: See attached design drawing for drainfield specifications. 3. SURFACE WATERS: There are no surface water concerns. 4. TOPOGRAPHY: As can be seen on the attached topography drawing, the average topography around the proposed drainfield is 5% running southeast to northwest. We are unaware of any adverse impacts this installation would have on adjacent wells or septic systems. If you have any questions, please contact us at 337-6179. Thank you for your assistance. 3701 East Tudor Road, Suite 101 * Anchorage, Alaska 99507-1259 Phone: (907) 337-6179 * Fax: (907) 338-3246 * Website: www.garnessengineering.com I ~/ ~ __~ ~ ~/I I / ~ ~- ~ = I I ~ % }~N, R3~,/SEC15, LOT/56 / I ~r ~ / J / I T12N, R3W, SEC15, LOT 6 I I ---~'~ %~----7 I ~1 ~ / I I //% ~ I I / ix I ~ I~ I ~ ~ I I JOHN ESTABROOK, 277-6655 1 OF 2 T12N, RSW, SEC15, LOT 57 PNB SITE PLAN : :.- DESIGN CRITERIA: GEG, Ltd. HAS A 8 PAGE SPECIFICATION NUMBER OF BEDROOMS: 3 LETTER l~AT PERTAINS TO THIS DESIGN, NOTE: THE CONTRACTOR TO OBTAIN A COPY OF 'lltE LETTER SHALL HAVE THE SOUTH & GALLONS PER DAY (GPD): 4~50 CONTACT GEG. BY PROCEEDING FORWARD EAST LOT LINES, AND ALL PERCOI..~TION RATE/S: 11.4- MIN/INCH WITH THIS INSTALLATION, THE ENGINEER, PROPOSED APPECATION RATE: O.B GPD/FT~ WELL DRILLER, CONTRACTOR AND WELL RADII FLAGGED BY A MINIMUM DRAINFIELD SQ. FT,: 563 GPO PROPERTY OWNER AGREE 1HAT THEY' REGISTERED LAND SURVEYOR HAVE READ THESE SPECIFICATIONS AND PRIOR TO CONSTRUCTION, DRAINFIELD DESIGN: AGREE TO ACCEPT THE TERMS AND CONDITIONS OUTLINED. / L~Gm: 45 FEET ~1 / EFFECTIVE: 7 FEET / / J ~ ACTUAL SO.FT.: 630 FEET~ / /I SCALE: -.~. / / 1"= 4-0 % ~ / / ~, x. / / ~ ~ /-~ T12N, R3W, SEC15, LOT 56/ ~"-. ~ ~.._ ..... ~.-N''~' / TH~4 --~--_ L1.25" PRESSURIZED LINE ~ ~\~ ......... , · GARNESS ENGINEERING GROUP, Ltd CIVIL & ENVIRONMENTAL ENGINEERS :~ ................... ~"'"'~'""~ ~, ~. ,~, ,~ ,,~ ,o,. ~. ~ ,,~, . ,~ ~,o,~ ,~-,,,, . ~ ~,o~ ,,-~,, . ~ ....,.~,,.,.,.~ PREPPED FOR: PHONE NUMBER: PAGE NUMBS: JOHN ESTAeROOK 277-66~5 2 OF 2 T12N, R3W, SEC15, LOT 57 PNB INITIAL SEPTIC SYSTEM DESIGN GARNESS ENGINEERING GROUP, Ltd ~,~ CIVIL & ENVIRONMENTAL ENGINEER,S ISOIL LOG - PERCOLATION TEST I LEGAL DESCRIPTION: T12N, R3W, SEC 15, LOT 57 PERFORMED FOR: JOHN ESTABROOK DATE: 5/23/14 ORGANICS GM ITEST HOLE #1 [ SOIL CLASSIFICATIONS OW ~ ORG GP ML GM CL GC OL SW HH SP CH SM OH SC DEPTH TO GROUNDWATER DATE DRY 5/23/~t4 DRY 5/30/14 TH#1 DATE READING CLOCK NET TIHE WATER LEVEL NET DROP TIHE (HINUTES) READING (IN.) (INCHES) 5/30/14 I 3:19 6 2 3:49 30 4.75 1.25 3 3:49 6 4 4:19 30 5 1 5 4:19 6 6 4:49 30 5 I PERCOLATION RATE 30 (MIN,/INCH) PERC. HOLE DIA. 6 (INCHES TEST RUN BETWEEN 5.0 FT. AND 6.0 FT. A FOUR HOUR PRESOAK WAS PERFORMED:" · YES [] NO SOILS LOGGED BY: ROB CAMPBELL PERCOLATION TEST PERFORMED BY: ROB CAMPBELL COHHENTS: PERCOLATION READINGS ARE WITHIN 1/16 OF INCH. PERFORMED BY GEG, Ltd. I, JEFFREY A. GARNESS, CERTIFY THAT THIS WAS PE/RFOF~MED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE: '7[,~. '~//~J" GARNESS ENGINEERING GROUP, Ltd ~,¢"~ CIVIL & ENVIRONMENTAL ENGINEERS [SOIL LOG - PERCOLATION TEST] LEGAL DESCRIPTION: T12N, R3W, SEC 15, LOT57 PERFORMED FOR: JOHN ESTABROOK DATE: 5/23/14 ORGANICS GM SOILS LOGGED BY: ROB CAMPBELL COMMENTS: [TEST HOLE #2 ] ORG ML GL OL MH ~CH OH SOIL CLASSIFICATIONS sc DEPTH TO GROUNDWATER DATE DRY 5/23/14 DRY 5/30/14 DATE READING NET TIME WATER LEVEL NET DROP TIME (MINUTES) READING (INCHES) 5/30/14 1 3:10 6 2 3:40 30 3.5 2.5 3 3:40 6 4 4:10 30 3.75 2.25 5 4:10 6 6 4:40 30 3,75 2.25 PERCOLATION RATE 13.33 (MIN./INCH) PERC. HOLE DIA. 6 TEST RUN BETWEEN 5;0 FT. AND 6;0 FT. A FOUR HOUR PRESOAK WAS PERFORMED: · YES [] NO PERCOLATION TEST PERFORMED BY: ROB CAMPBELL PERCOLATION READINGS ARE WITHIN 1/16 OF INCH. (INCHE~ PERFORMED BY GEG, Ltd. I, JEFFREY A. GARNESS, CERTIFY THAT THIS WAS PE~FOR~IED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE: GARNESS ENGINEERING GROUP, Ltd !~'~;~: ~; ~:~ CIVIL & ENVIRONMENTAL ENGINEERS ISOIL LOG - PERCOLATION TESTI LEGAL DESCRIPTION: T12N, R3W, SEC15, LOT 57 PERFORMED FOR: JOHN ESTABROOK DATE: 6/17/2015 ORG/LOAM ITEST HOLE# 3I SOIL CLASSIFICATIONS GH ORG ['iL CL OL MH CH OH SC DEPTH TO DATE GROUNDWATER DRY 6/17/2015 DRY 6/26/2015 SITE PLAN SCALE: DATE READING CLOCK NET TIHE WATER LEVEL NET DROP T/HE (MINUTES) READING (INCHES) 6/18/2015 I 2:05 6" 2 2:35 30 3 1/2" 2 1/2" 3 3:05 6" 4 3:35 30 3 3/8" 2 5/8" 5 3:35 6" 6 4:05 30 3 3/8" 2 5/8" PERCOLATION RATE I~IN./INCH) TEST RUN BETWEEN 5% AND A FOUR HOUR PRESOAK WAS PERFORMED SOILS LOGGED BY: DAVID GARNESS PERCOLATION TEST PERFORMED BY: COMMENTS: PERCOLATION READINGSARE WlTHIN1/16OFINCH. PERC. HOLE DIA. FT. 6 YES · NO [] ERIK WIDGER CINCHES) PERFORMED BY GEG, Ltd. I, JEFFREY A. GARNESS, CERTIFY THAT THIS WAS PER?ORM~D IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE: GARNESS ENGINEERING GROUP, Ltd ~ ~;~;' CIVIL & ENVIRONMENTAL ENGINEERS [SOIL LOG - PERCOLATION TEST] LEGAL DESCRIPTION: T12N, R3W, SEC15, LOT57 PERFORMED FOR: JOHN ESTABROOK DATE: 6/17/2015 ORG LOAN [TEST HOLE # 4I SOIL CLASSIFICATIONS ORG HL CL OL HH DH OH SC DEPTH TO DATE GROUNDWATER DRY 6/17/2015 DRY 6~6/2015 SITE PLAN SCALE: GH DATE READING CLOCK NET TIHE WATER LEVEL NET DROP TIHE (HINUTES) READING (INCHES) 6/17/2015 1 2:00 6" 2 2:30 30 3 3/8" 2 5/8" 3 2:30 6" 4 3:00 30 3 3/8" 2 5/8" 5 3:00 6" 6 3:30 30 3 3/8" 2 5/8" PERCOLATION RATE 11(41IN.lINCH PERC. HOLE DIA. CINCHES) TEST RUN BETWEEN 5.15% AND FT, 6.5 A FOUR HOUR PRESOAK WAS PERFORHED: YES .0 [] SOILS LOGGED BY: DAVID GARNESS PERCOLATION TEST PERFORHEB BY: ERIKWlDGER COHHENTS: PERCOLATION READINGS ARE WITHIN 1/16 OF INCH. PERFORMED BY GEG, Ltd. I, JEFFREY A. GARNESS, CERTIFY THAT THIS WAS PERFiORME.):) IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE: • • Municipality of Anchorage On-Site Water&Wastewater Program R ' Rv_ • (907)343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL Parcel I.D. 015-05-228 Expiration Date: 1 1. GENERAL INFORMATION Complete legal description T12N, R3W, SEC15, LOT 57 Location (site address) 9501 ELMORE ROAD *ANCHORAGE, AK 99507 Current Property owner(s) JOHN AND GERALDINE ESTABROOK Day phone 907-227-6655 Mailing address 9501 ELMORE ROAD *ANCHORAGE, AK 99507 Real Estate Agent Day phone 2. TYPE OF DWELLING: 1.1 Single Family (w/wo ADU) ❑ Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) 3. NUMBER OF BEDROOMS: 3 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well I Individual On-site 111 Individual Water Storage ❑ Individual Holding tank ❑ Community Class Well El Community On-site ❑ Public Water System ❑ Public Sewer ❑ WaiverNariance request for. IA A Distance: — Received by: Date: 87/q//g COSA to be released to the engineer,unless otherwise requested by the engineer. COSA Fee$ a to?.5-6 Waiver Fee$ Date of Payment g1 Z /12 Date of Payment Receipt Number 631?-76 Receipt Number COSA# [J f IF/3(3q Waiver# 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, i verify that my investigation, based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are)in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm GARNESS ENGINEERING GROUP, Ltd. Phone 337-6179 Address 3701 E.TUDOR ROAD, SUITE 101 *ANCHORAGE,AK,99507 e NI Engineer's Printed Name JEFFREY A. GARNESS, P.E. Date Engineer's Comments: in conducting this evaluation.GEG provided an engineering evaluation of the well and/or septic system in accordance with the vilIS S►%i, guidelines and regulations established by the Municipally of Anchorage and industry practices.The reported results describe the �4%, OF 4 "4 condition of the systems on the date/s of the evaluation.Separation distances were measured to readily identifiable features. ••� •• �� ��v Hidden defects or encroachments may exist that were not identified during the evaluation.The operational life of all wells and septic �'.•'••••••••••••• ••'••• • systems depend on a variety of variables including,but not limited to,soil conditions,groundwater levels(that may fluctuate during � v. i the year),quality of construction(materials and workmanship),and the water usage of the family utilizing the system's.These s * /N * #. conditions can vary,and are outside the control of GEG.Satisfactory test results do not guarantee future performance of the a 0 system's:therefore.GEG makes no warranty(express or implied)regarding the future performance of the well or septic system. I • 0 GEG makes no representation whether an alternative well or septic system can be installed on the property in the event either of the /1, current systems fail.The content of this report is for the sole benefit of the person/party who retained GEG.Reliance upon the • • 1. e A, Garn-gs ��. information provided in this report by any other person or party,including but not limited to subsequent property purchasers,is not •.C C. CE/r......,,,,,E, •.• I authorized.In short,GEG disavows any legal duty to anyone other than the person/pally who paid for this report. • J> •.•• f i ,..... ... ". ...• . 6. DSD SIGNATURE 4tr�PROFESS\���4� LICENSE 4IIlui `iv* #AECC884 70 System#1 Approved for 3 bedrooms. 1, System 1 l,r 1, System#2 Approved for bedrooms. ' 1„•/.. Disapproved. . G. wON'SITE Y, W� ER AND Conditional approval for bedrooms, with the following stip,�ilatton 'TEWATER c '.^ PROGRAM ,c B . ^--- (--S,X—"-f Original Certificate Date: O ^ / 7 ^r W The Municipality or Anchorage Develop,emt Services Division(DSD)issues Certificates of On-Site Systems Approval(COSA)based only upon the represenatations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTCHMENTS: COSA Checklist ) _ Nitrate Advisory Septic System Advisory Arsenic Advisory Well Flow Advisory Other (Rov 10117/171 If more than 1 septic system is on the lot: COSA Checklist# of Structure served by this system Certificate of On-Site Systems Approval Checklist Legal Description: T12N, R3W, SEC15, LOT 57 Parcel ID: 015-05-228 A. WELL DATA Well type PRIVATE If A, B, or C provide PWSID# N/A Well Log (Y/N) YES Date completed 6/22/17 Sanitary seal (Y/N) YES Wires properly protected (Y/N) YES Total depth 200 ft. Cased to 199.77 ft. Casing height (above ground) 18+ in. FROM WELL LOG AT INSPECTION Date of test 6/22/17 NEW Static water level 146.8 ft. ft. Well production 10 g.p.m. g.p.m. WATER SAMPLE RESULTS: Coliform NEG colonies/100 ml. Nitrate 1.87 mg./L. Collected by: GEG, Ltd. Arsenic: `5 ug./L. Date of sample: 6/21/18 B. SEPTIC/HOLDING TANK DATA Tank Type/Material SEPTIC/STEEL Date installed 11/22-23/16 Tank size 1000 gal. Number of Compartments 2 Cleanouts (Y/N) YES Foundation cleanout (Y/N) YES Depression over tank (Y/N) NO High water alarm (Y/N) N/A Date of pumping NEW Pumper - C. ABSORPTION FIELD DATA *BELOW FINAL GRADE Date installed 11/22-23/16 Soil rating kp.d./ft or ft2/bdrm) 0.6 System type DEEP TRENCH Length 55 ft. Width 2.5 ft. Gravel below pipe 7.05 ft. Total depth *11.40 ft. Eff. absorption area 770+ ft2 Monitoring tube YES Depression over field NO Date of adequacy test NEW Results (Pass/Fail) PASS For 3 bedrooms Fluid depth in absorption field before test - in. Water added - gal. New depth - in. Elapsed Time: - min. Final fluid depth - in. Absorption rate >= 450+ g.p.d. Any rejuvenation treatment (past 12 mo.) (Y/N &type) NEW If yes, give date - kfi J D. LIFT STATION r.., Date installed Size in gallons Manhole/Access(Y/N) 143 e r "Pump on" level at in. "Pump off'level at in. - . " . -r a arm level at in. 1 Datum Cycles tested Meets alarm &circuit requirements? 11 J E. SEPARATION DISTANCES r., SEPARATION DISTANCES FROM WELL ON LOT TO: Septic tank/lift station on lot 100'+ On adjacent lots "100'+ 100'+ Absorption field on lot On adjacent lots `1004 Public sewer main 75'+ Public sewer manhole/cleanout 1004 Sewer/septic service line 25'+ Holding tank i c c �.'- 1 t'' Animal containment areas 50'+ Manure/animal excrete storage areas "1004 SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundation 10'+ Property line 5'+ Absorption field 5'+ Water main 10'+ Water service line 10'+ Surface water 100'+ Wells on adjacent lots 100'+ SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line 104 Building foundation 10'+ Water main 104 Water service line 10'+ Surface water 1004 Driveway, parking/vehicle storage 104 Curtain drain 10'+ Wells on adjacent lots 100'+ F. COMMENTS 'WITH CAVEAT-THE LOCATION OF THE SEPTIC SYSTEM FOR THE CHURCH TO THE WEST IS BELIEVED TO BE 100'+ FROM THE SUBJECT WELL BUT CANNOT BE PHYSICALLY VERIFIED. ....... ..... •• • j— ••v1 I certify that I have determined through field inspections and wilt : 4' I. �'" . �• review of Municipal records that the above systems are in • conformance with MOA COSA guidelines in effect on this 0....;( • •.� • • date. ..G-... : f y •. -•rness.v= Engineer's Print d Name JEFFREY A.GARNESS .•% . CE 79-i Ti ci� �= `� 9/ • Date LICENSE//4:Ro"S" : • #AECC884 (Rev.10/12/12) HOUSE DETAIL c0. o 30,1' 14.0' SCALE: 1"=40' - . 0.• 0 14.0' 34 1' cn 6' `° ` 0. 6--0--77 A • r N • p ' N9 ••S u ' - ``•"` 19 9 .>. s 13.9' v N `56 . -51',C9 N ti. J CO 40C I I I Lot 56 I Lot 55 I I I I I I 50.0' N 89'55'31"E 279.77' co \ b? 54.7'__ - N 1- Z 0\ iiii0110111 q54.9' oq \ p - N /73 N d 1p n'I m \ot 58 Z7 Q, a, I O .03 > 0) ROSECtNE RP�1U5 WELL I \ P / S 89'51'28" 280.23' SEPTIC PIPES \\ / Lot 64A Lot 63 FOl.1Nt'7P'1'1v1--1I �Lhtl-I- iv-17 Star rS1C 4:21,i‘•`j , PLOT PLAN AS BUILT SCALE 1" = 60' GRID SW 2436 Project No. 17-244/B4 11500 Daryl Avenue, Anchorage, Alaska 99515-3049 Lang & Associates , inc . (907) 522-6476 Phone Q00000‘, (907) 522-4625 Fax o Professional Land Surveyors kenOiangsurvey.com v F �Q jonathanOlangsurvey.com 'c\�' 4 O I hereby certify that I have surveyed the following described properly: ��� BLM LOT 57, SECTION 15, T12N, R3W, SEWARD MERIDIAN, ALASKA *• 49TH i� • *�A Anchorage Recording District, Alaska, and that the improvements situated thereon are 0 within the property lines and do not encroach onto the property adjacent thereto, that no improvements on the property lying adjacent thereto encroach on the surveyed KENN ' �0 premises and that there are no roadways, transmission lines or other visible %)cV... ^ oQeasements on said property except as indicated hereon. .p '•.,LS-5 0 • •4 Dated this the Z(a Dayof •••••' J 0 r^'� L� $ at Anchorage, Alaska 0�4``D A o0 QOROFfSSIONAt o It is the responsibility of the owner to determine the existence of any easements, DOpppooa covenants, or restrictions which do not appear on the recorded subdivision plat. AECC963