HomeMy WebLinkAboutTHE VILLAGES TR 17 MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND HUMAN SERVlCI"S Environmental Heallh Division 825 %" Street, Anchorage, Alaska 99502, Telephone 264-4720 ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT Na.~e DISTANCES _ ~ TANK FIELD LEGALOESCRIPTION LOT LINE ~ / ~WO ~ ~'o'/ TANKS _ __ N ~ SEPTIC ~ HOLDING ~ ~e TYPE OF SYSTEM '~ ~ ~ ~ :'~,,~ TRENCH ~ BED O W. DRAIN ~ OTHER ~/ ~ ~ Depth '0 pipe bdt'om f .... Total depth ,rom o',flinal grade / ~ WELLS ~ ~ / ~ PRIVATE ~ OTHER {Identify} / ~2 q r' __ I / , ~e ~ -- cedlly Ihatthio inspealon was pedormed according lo ag Municipal 8nd Slats guidelines In eliect on Ibis da~ 2 ~ ~/~ ~ ¢ / 72-013 (3/85) Tom Fink, Mayor Department of Health and I-luman Services 825 "L" Street P.O, Box 196650 Anchorage, Alaska 99519-6650 343-4744 January 9, 1989 Richard E. Abbott 2024 Borealis Apt A Anchorage, Alaska 99503 Subject: Tract 17 The Villages Subdivision Permit #880168, PID #020-301-i~ Municipality of Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES PO Box 196650 Anchorage Alaska 9951'9-6650 On-Site Services/Water Quality #502 Richard E. Abbott 2024 Borealis Apt A Anchorage, Alaska 99503 ...... ~,,~' .' F'FK) "l':['.i'~l~:~ E3<F'D .., :,:, ,:..j RETI'LR.N TD ~: ' Sincerely, Daniel J. Rot Acting Program Manager On-site Services Section DJR/ljw enc: Copy of Permit MUNICIPALITY OF ANCHORA(~E DEPT. OF HEALTH & ENVIRONMEN [AL PROTECTION JAN 1 7 1989 RECEIVED Department of Health and Human Serwces' 825 '%" Street Tom Fink, Mayor P.O. Box 196650 Anchorage, Alaska 995'19-6650 343-4744 January 9, 1989 Richard E. Abbott 2024 Borealis Apt A Anchorage, Alaska 99503 Subject: Tract 17 The Villages Subdivision Permit #880168, PID ~020~301-14 A permit issued by this Department for an individual well and/or on-site sewer system has expired as of December 31, 1988. Permits are issued on a calendar year basis by authority of Municipal Ordinance. A new permit must be obtained from this Department for any well and/or on-site sewer system not installed by the expiration date. If you have drilled the well, a well this Department for documentation of close the permit. log needs to be sent to the installation and to If a private engineer inspected the installation of the on-site sewer system, the original as-built inspection report (three-part form) must be sent to this office for review and approval, and for documentation. When applying for a new permit, the fees are: $90.00 for an on-site sewer permit; $50.00 for a well permit; $140.00 for a combined sewer and well permit. If there are any further questions, please call this office at 343-4744. Sincerel. y~ Acting Program Manager On-site Services Section DJR/ljw enc: Copy of Permit CiN'"S]:Tliil !31EWEEI:R ~ SE:F"I]:C 'FANI'::: ,?..< WE!J.,.I. Pli!:FIPIi['f' F?]:CHAI:RD E,, ABBE)I'T 2:~()2-':1, B()F;,' ~[ I~l.,r, ]i !3 APT. A ','31EF" I :[ C 'f'P/Iql-( :: H :t n J. mLLm 'L c)±. a I ~rM:l'l:, J. c:: ~: an k c al:tat :L 'L y i: t.(:)f::) clf' !~;6.)pt. :i. c: 'L e:~r'l I< (~{~) -::/ zl. ,, 0 · E;P4qD I::: ]: L.I., 'TD IdP~]:NT(.~:[Iq 6' C}VEi:R )31E:0r~c)DK,, L. ENEYI'I,hl -'.1.~', N]:I)'f'H, I~'lDt. llxlD SI.,,C)I::'E NE)T rc) EXCILIED ::i;:i :[,, NC]T'):F::'Y DHI. IS f;:'IR:[C)F;: TC) ]:N,~;F:'E!:EFf':[t::)Iq. Tkl]:~ PE:RH:[']' ]:S ]:~3~!JLff:!:D F'I3R ¢~ S]:Nf3[,.IE FY,~I~I:[L,Y :1: I:;liERT :1: FY I"I'I~YI',', 2,,, :t: ~:i,:l.:[ :Lm~vL~:~],l 'Ll'm) ~;vs~t.(..:ml ~.rl accor'darlc:~::,~ t.~i'Ll"~ all VID(,~ c:(:)d(m~ and :::.~,, :1: ~:i.:l, Jl. ac:lh6H*~ t,c) aJ.]. HC)P/ ar'icl St, a'L(,2 af ~.~:l.a~sl.::a r'6H:lLl:Li-e~m6,H"d:.!~i f(:H" 'Lf"m) ~:~;.:'(.. bat:l:: D J. ~:1 n I.~d ~ . :~ ............... ~.,~...,.., ((::Mc're, P). I::R t:[ I"lf~ E:. [M313EFI"'T ~ '°,/ ALASKA eUIROFImeFITAL £OFITROL S RUICeS, IFI£. · ~% ~nqinm'in§ ~ ~nuironmcntd ~ludk~ SPECtFJCATIONS FOR BED IqASTI';WATF, R TRRATMENT SYSTEM LEGAL DESCRIPTYON: TRACT I7 TIIE VILLAGES SUBDIVISrON 1 , 0 GIiNI".RA1, 1.1 Thc drawings, sheels 1 throagh 4, shal] be purl of this specification. !.2 Alt materials and wOPklltanship shall meet the Pequh'elllellts of l}le Huui,:ipa 1 J ty u f Anehopage, gepar Onen L o ¢ Ileal LI] &ttuman Services (DIIIlS) , the conditions of Che pepmit, aud a]l apl)iJcabie pules alld regtllatJo~ls cuprent]y ~n effect. !.3 Ali cxcavatioas and depths ape advisory, and are to be wepified modified in the field by the Engineer or iuspectJug ~gency. ].4 It is; Lhe respensibi]ity uf the owner ur {hstaller L() adhere h) appruved desiga for the installat~oa, to maJntaiu {he specified sopupatiou if the installation is not inspected by all AECS eugiaeer, AECS w]]] not be ;'espolmible for the ins['a]led system. An engineeu at AECS should be that wJl] be cequlred and to exp]ain whnL these JllspectJOllS will involve. 2.0 Septic Teak 2.1 The existing septic tank may be used, [f it meets the capacity requireme, at fop the residence and the approval of I)lfIIS. !f not. then specifications 2.2 through 2,6 apply. 2.2 The septic tank shall be a UPC Approved two compartmenL tklllk, constPtlcted of 12 gauge steel with bitalnastic coatillg and set level on Ul]dJstupbed soil. if t'he t:ank [s bapJed at a depth of 4 feet or less, [k most he insulated with an overlying layer of 2 inch hurJa] type po]ystyrene rigid bourg insulation. 2,3 The septic tank shall be a m:lnilnUln of 5 Feet from the }muse foundation, and a IilillhRUIII ef 5 foet fPOII/ the absoFption vpeu, 2.4 The sept:it tank and bed shall be a lnhlillitlll/ oF 100 feet froln aay Iii'irate well or body of water, 150 fee( from Class 6 wells, uud 200 fee% from Class A op B wells, unless otherwise specified. Less than the requh'ed separation distance must have pl'Jop approwal er waiver by DHItS or Alaska Department of Favironmenhal Consel'vatJoa (ADE(]). 2,5 Piping shall be fitted with a mechanical watertight calder coupling on the outlet and ialet of the. septic tm~k, Inlet p:[p]ng shall he 4 inch solid PVC ASTM 133034 or east iroo, sloped a miniature of !/4 ilmh per ]iaea] fool', Outiei piping sha]! eot be less than i/8" per fooi slope. If the piping buried at a depth of 4 feat or less, it must be ]u'au]ated with un 1200 ~Jesl 33rd Avenue. ~uile 8ognch0roqe, ^l~sko 99503.(907) 561-5040 2.6 3.0 o. 1 3.2 3.3 3 . 6 °.7 oveplyfng layer of P- inch bur[ul ~ype polysi'rene rigid board C]eanouhs shall be instal]ed as clesigmtted and cP, pped with a4p tighl raJ~ caps (,J;i!lt caps op equiva~enh), and ex~end ~ minimum of I fooi: ubove gpol id level. Bed The sand sba]] have an effocLive size of 0.4 Io 0.6 31,1 alit! coeffJcent of not nlore than 4. The gravel for till? bed shall be 0.5 ko 2.5 :illth. screened rock with less than 3% passing #200 sieve residual. All substitutes must have prior DH}IS approval. The botLom oF [he excavation shail be ]eve[ slid raked wiih [he backhoe The dishr[bu¢lon pipe shall be pcrforahed 4 inch rigid PVC w:[U~ a n!inimunl crush stpelgth of t500 pounds and shall Ineet the approval of I)IIHS fo[' use t'.s draiufieJd pipe. Al] pipes shall be laid level, and spaced according to ~h~! dl'aWillgS. MoniLor standpipes shall be placed as shown Jn [he drmx, ings. They shall be 4 inch rigid PVC AS'PM D 303'i. op east iron. The section shown wihh holes may be either drilled 0.5 inch holes on 6 inch centm-s on oppo~*ing sides of the pipe, or a sechion of regular pepforated sewer pipe may be clamped to klm isol~d sech~on wiLh ;1 no hub coupJ lng or so!veni: joint, Perforated section shall be located in grave] only. The port;Jori of pipe above the sewer pock shall be solid. A i'ubbe~~ i'a~ncap (Jill/ C*lp oF equivalent) shall be placed ovep t:he top of the pips. If [he CJllal grade over file bed is lets Umn 4 leek above [he gravel, tnsuiat.ion is required, using burial type po]ysteae pig~d boapd insulation. There shall be ] inch of insuJatJon for every foot: of less than the required 4 feet of cover, but there must be at least 24 Jl]ci]es of soil evell though insulation is used. The so]id pipe extending fpom the septic 2ank to the drainfJeld shall also have 4 feet of cover an equJvaienL iaye;' of insulation combined i~,itth soil. Po]y Filter X, or equivalent). The top at~d sides of the bed shall be planted lx, i/:h a tqhite clover and red ,I .0 [llspec lions Jl!~;pPcJlfOD Will ?)e Of the opell exeav~LJoll. {1o assk.-e that the systei~ The tae(:ond inspection wJl~ be pepfoL'med ail:et' sand fill Js installed, but pl'JOl' i:o p]a(:ement af g~'ave] and dJstpiblltJol~ pipes. This [nspecl:Jo~ will ver~fy that /:he fil]ep is ppoper]y insl;a]]ed, that it meets specifications and that it fulfil]s the ~ntention [~f the design. The .hJpd Jnspeclion will be a/'tf)p I)]aeelnen[ of gpaveJ, mmlttop standpipes, and distpibution pipe, to ve)'ify pt'ope~' installaCion and pos:ki[on of' pipes pr/oL- to backF.[ll, The inspection of' the septic tank installation can be incor'po~-ated wilh ~tlly Ollf; O[ I}/e above 1isLed inspeeLions. ALASKA ENVIRONMENTAL CONTROL SERVICES, INC, 1200 West 33rd Avenue, Suite B ANCHORAGE, ALASKA 99503 (907) 561-5040 CHECKED BY DATE- SCALE-- ~ /''~ ~ / ALASKA ENVIRONMENTAL CONTROL SERVICES, INC. 1200 West 33rd Avenue, Suite ANCHORAGE, ALASKA 99503 (907) §61-§040 SHEET NO, CALCULATED BY CHECKED BY. OA'rE ALASKA ENVIRONMENTAL CONTROL SERVICES, INC. 1200 West 33rd Avenue, Suite ANCHORAGE, ALASKA 99503 (907) 561-5040 CHECKEO BY DATE EASEHENTS OF RECORD, OTHER THAN THOSE SHOWN OH THE RECORDED PLAT, ARE NOT SHOWN HEREON. _LOT SURVEY CEIRTIFICATION.--- _-I-'HE I/ ANCHORAGE REC:ORDING DISTRICT ' P~gPA~'D BY: DOWLIN6-~' 'ASSOCIATES ~"]~2~'H~d~'~ ~ee~', · '"'..,:~',. ~ ANCHO'RA6E~ ALASKA 99501 .. W,O, Residenc~l of'. PERFORMED FOR: LEGAL DESCRIPTION: 5- 6- 7- 8- 9- 10- 11 13- 14- 15- 16- 17- 18- 19- 20- Municipality o! Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 025 "L" Street, Anchorage, Alaska 99502-0650 SOILS LOG -- PERCOLATION TEST Township, Range, Section: SLOPE SITE PI_AN WAS GROUND WATER ENCOUNTERED? , /JO -- S L IF YES, AT WHAT O DEPTN? p E Moniloring? Oale; Reading Date Gross Net Depth to Net Time Time Water LL~ 1;27 ~r- ~,(o7 -. ~,yO ~, /~ PERCOLATION RATE ~ - (mmuteshnch) PERC HOLE DIAMETER TEST RUN BETWEEN (~ . FT AND /' FT PERFORMED BY: r~ , /?~ ,c/ I '-'~--- CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: ~,,~//,/~" , 72-008 (Rev. 4/85)